Search criteria
27 vulnerabilities found for integrated_lights-out_5_firmware by hp
FKIE_CVE-2021-46846
Vulnerability from fkie_nvd - Published: 2022-12-12 13:15 - Updated: 2025-05-02 20:15
Severity ?
6.4 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:L
6.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
6.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Summary
Cross Site Scripting vulnerability in Hewlett Packard Enterprise Integrated Lights-Out 5.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:integrated_lights-out_5_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3D179C62-EA44-4D6F-B4ED-B5E9C1674FC1",
"versionEndExcluding": "2.44",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:3par_service_processor:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7A9EB35E-D915-4C4E-81F5-8DAC3FD2336C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:apollo_r2000_chassis:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9311154A-E0EF-46B3-B8D0-6ED540029684",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:apollo_2000_gen10_plus_system:-:*:*:*:*:*:*:*",
"matchCriteriaId": "03743177-70D4-442B-B59F-43912385CC83",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:apollo_4200_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CFB818A6-80D5-4DD7-8E0D-EC25764A0693",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:apollo_4510_gen10_system:-:*:*:*:*:*:*:*",
"matchCriteriaId": "25418088-0890-401E-837C-611154B2C433",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:apollo_6500_gen10_plus_system:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D1480B92-9A59-4675-B2DF-6DAE385927B2",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:integrated_lights-out_5:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2D5370AF-C0B8-4E75-8B01-A4239B130E9E",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C25FD273-0E16-4975-985C-8BD96AE0D449",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5876FB45-B037-4355-BAE9-69157FD0A402",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F0C77CAF-0A18-4447-93BD-C64595475E37",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "08D81BA5-E5D8-4D42-8C42-A91063008359",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B15D52EA-CE63-47AF-993D-265163B5B38E",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B1F98CB6-3933-4425-A7E9-542AB764C8C4",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "93765BE7-D8C2-48C8-9ADA-A7C36B993D95",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FD08B95A-240C-436E-91B5-2D594F6F1F07",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8545248A-2943-4B8D-A295-BE7D43492BC9",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "00B032E4-9663-4525-ACC4-217B5E266124",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D3845235-CAFC-4FB3-AB26-F0E8A8815F88",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B8389F7F-7653-4695-91CC-DCFACC870094",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "419470B4-80EF-46BF-8DB4-6569D3E8435F",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_dx385_gen10_plus_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "594B767B-41AB-436A-AF2C-10185E1161F4",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_e910_server_blade:-:*:*:*:*:*:*:*",
"matchCriteriaId": "174EF59C-18A6-4490-A23A-76E74C1D2AFA",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_e910t_server_blade:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C755817B-B074-4496-934B-A30C72A4F849",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_m750_server_blade:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E79D5665-6654-4AF7-A3DE-7F338067E8C3",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_microserver_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A3A4A379-205A-479C-9C82-B182AEAEB8B8",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_microserver_gen10_plus:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2F8B5AC2-7889-4654-88D2-289CE20A4ED7",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DB32875E-11E3-443E-809C-12CCAE574570",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "76C24685-FEE2-494F-9806-56477E62FD1A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C7DE16BA-939E-4C26-B03B-439E60C7C872",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4B224273-2E15-41F2-84D6-D754F6B76B49",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1ACD7139-05F6-4D60-BB0F-9AA6952720CA",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_xl220n_gen10_plus_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "01181BEB-DE0B-49AA-B632-91B40046120F",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "50247A44-3EA0-4B4B-9AB6-64D9B470F190",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1A21F0B8-D613-46CD-BAEC-5CD876FD5352",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_xl290n_gen10_plus_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4435D5C3-A7CB-4EA6-87A9-6026DAC8DA47",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DBD81201-ECD9-4E9F-A6F0-7EAEB1DA9891",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_xl645d_gen10_plus_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "424298C0-01E2-4770-818D-25F47A801F88",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:proliant_xl675d_gen10_plus_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1E7408A4-7409-4223-ABA7-C1F35E84D213",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:storage_file_controller:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EBCBE981-8F98-49B2-B09D-B0187D5DF322",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:storeeasy_1460_storage:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BFC69BAD-3243-405F-839E-8BE9E2562205",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:storeeasy_1560_storage:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C386FE40-4223-4F35-A04A-84008B7A1B8E",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:storeeasy_1660_expanded_storage:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A3E86E62-1B51-4934-B8B6-40D920BE6192",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:storeeasy_1660_storage:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EFC53F93-901B-40A9-BAAD-DD5A8865E824",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hpe:storeeasy_1860_storage:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D82CC8E6-A017-406E-B993-4CFFEB230829",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Cross Site Scripting vulnerability in Hewlett Packard Enterprise Integrated Lights-Out 5.\n\n"
},
{
"lang": "es",
"value": "Vulnerabilidad de Cross-Site Scripting en Hewlett Packard Enterprise Integrated Lights-Out 5."
}
],
"id": "CVE-2021-46846",
"lastModified": "2025-05-02T20:15:17.440",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 0.9,
"impactScore": 5.5,
"source": "security-alert@hpe.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-12-12T13:15:11.917",
"references": [
{
"source": "security-alert@hpe.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04133en_us"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04133en_us"
}
],
"sourceIdentifier": "security-alert@hpe.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2019-11982
Vulnerability from fkie_nvd - Published: 2019-06-05 17:29 - Updated: 2024-11-21 04:22
Severity ?
Summary
A remote cross site scripting vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:integrated_lights-out_5_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1EEFA032-2828-4A25-AA69-490AAF9B7F1E",
"versionEndIncluding": "1.39",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BFEC03C5-6E25-47A3-9793-D411056F5D08",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl120_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "43D747DD-AF47-4B5A-B9CC-20BEC97E7788",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl160_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7B0DEA2A-F511-4111-8B33-B029E75D56BF",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl180_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5077B450-1E11-4338-8F76-E4257FBE9260",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl20_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A66883DD-061A-4D0A-A73B-3EF2F7273B83",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl325_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E013812C-A291-4F5E-BA62-B034FA8288ED",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl360_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "45369573-58FC-40E2-8124-08CDEAB6B6C0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl380_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1F5D074B-079C-4227-A2A5-654BB35E7DC3",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl385_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F0766C25-5149-4A02-BC12-38D21EAE2303",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl560_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D894E6C9-D248-4800-A138-CD0FE8F6B5B9",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl580_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8FEBB303-F21A-47FF-9D79-5CBC90144782",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_microserver_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2D8F597A-DBF1-4CA5-9B10-990571E2A968",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ml110_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DA54BDB5-28DF-46D6-8D7D-F2F4F3B21381",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ml350_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7FF6A55B-05B4-4286-BF06-45D2A21EF58F",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A6662F50-79E8-4675-ABAB-E95C7B8A2BBB",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0D33F488-C5DB-40A7-BCAB-4DA1A6FC0096",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "85739B50-AA18-4097-8EAA-3A750EE38AE6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl450_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2C2B30A8-303D-4A47-8D9A-7088F82D2BA3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:integrated_lights-out_4_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "63301635-7C6F-4854-893C-C37B74F13511",
"versionEndIncluding": "2.61b",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:proliant_bl460c_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E58291DF-A83D-4EED-8CEB-DCCB636E57F4",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl120_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5010CA27-8B1D-43BE-A236-997E51E4B541",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl180_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "67D2605F-2642-46EB-BA2C-8E33ACEC8ADA",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl360_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "87200D92-81D3-4FA4-BD4D-11F0DB7C1E45",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl380_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "81E5D6BA-A5C8-42B2-B347-1F3A70DCDC9D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl580_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8ED47EFC-2D0D-4864-A0CC-A6F29C236315",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ml10_gen9:2:*:*:*:*:*:*:*",
"matchCriteriaId": "97685B5D-843B-4BA4-915C-A384F323A206",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ml110_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D64DCBE5-8590-4F17-A86D-88B78E9E5943",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ml150_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B9876313-D746-4077-A188-F2024C3689F3",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ml30_gen9:2:*:*:*:*:*:*:*",
"matchCriteriaId": "2C53512F-3577-4F64-977C-6579124DA93C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ml350_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1D95AA33-FD84-4766-A42A-4E44A1BC9B8B",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ws460c_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "76D7479C-E340-4E58-A5E5-5AA7C95EE90A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl170r_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6C7DE17C-AC8E-4C0B-B6B1-6D2F4958E70A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl190r_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2838C1A2-23B2-4063-8C16-1558FC329EEB",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl230a_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "40FCFF2E-22B6-4AE3-AE36-B57524656128",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl250a_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CE0AA43F-DEFB-441C-84B8-85F523D600C0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl730f_gen9:*:*:*:*:*:*:*:*",
"matchCriteriaId": "76C1B4FA-E67A-4EB7-A428-FF6C90F0E3B7",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl740f_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3CFED4E5-48AA-4133-A2A2-4D70101593A4",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl750f_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6890F055-67AE-4008-A687-EEAD92D892BD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A remote cross site scripting vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39."
},
{
"lang": "es",
"value": "Fue encontrada una vulnerabilidad de tipo cross site scripting remota en HPE Integrated Lights-Out 4 (iLO 4) anterior a la versi\u00f3n 2.61b para servidores Gen9 e Integrated Lights-Out 5 (iLO 5) para servidores Gen10 anteriores a la versi\u00f3n 1.39."
}
],
"id": "CVE-2019-11982",
"lastModified": "2024-11-21T04:22:06.240",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.6,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:H/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 4.9,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.6,
"impactScore": 6.0,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-06-05T17:29:00.227",
"references": [
{
"source": "security-alert@hpe.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
],
"sourceIdentifier": "security-alert@hpe.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2019-11983
Vulnerability from fkie_nvd - Published: 2019-06-05 17:29 - Updated: 2024-11-21 04:22
Severity ?
Summary
A remote buffer overflow vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:integrated_lights-out_5_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1EEFA032-2828-4A25-AA69-490AAF9B7F1E",
"versionEndIncluding": "1.39",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BFEC03C5-6E25-47A3-9793-D411056F5D08",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl120_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "43D747DD-AF47-4B5A-B9CC-20BEC97E7788",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl160_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7B0DEA2A-F511-4111-8B33-B029E75D56BF",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl180_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5077B450-1E11-4338-8F76-E4257FBE9260",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl20_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A66883DD-061A-4D0A-A73B-3EF2F7273B83",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl325_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E013812C-A291-4F5E-BA62-B034FA8288ED",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl360_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "45369573-58FC-40E2-8124-08CDEAB6B6C0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl380_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1F5D074B-079C-4227-A2A5-654BB35E7DC3",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl385_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F0766C25-5149-4A02-BC12-38D21EAE2303",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl560_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D894E6C9-D248-4800-A138-CD0FE8F6B5B9",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl580_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8FEBB303-F21A-47FF-9D79-5CBC90144782",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_microserver_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2D8F597A-DBF1-4CA5-9B10-990571E2A968",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ml110_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DA54BDB5-28DF-46D6-8D7D-F2F4F3B21381",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ml350_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7FF6A55B-05B4-4286-BF06-45D2A21EF58F",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A6662F50-79E8-4675-ABAB-E95C7B8A2BBB",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0D33F488-C5DB-40A7-BCAB-4DA1A6FC0096",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "85739B50-AA18-4097-8EAA-3A750EE38AE6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl450_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2C2B30A8-303D-4A47-8D9A-7088F82D2BA3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:integrated_lights-out_4_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "63301635-7C6F-4854-893C-C37B74F13511",
"versionEndIncluding": "2.61b",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:proliant_bl460c_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E58291DF-A83D-4EED-8CEB-DCCB636E57F4",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl120_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5010CA27-8B1D-43BE-A236-997E51E4B541",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl180_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "67D2605F-2642-46EB-BA2C-8E33ACEC8ADA",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl360_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "87200D92-81D3-4FA4-BD4D-11F0DB7C1E45",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl380_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "81E5D6BA-A5C8-42B2-B347-1F3A70DCDC9D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl580_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8ED47EFC-2D0D-4864-A0CC-A6F29C236315",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ml10_gen9:2:*:*:*:*:*:*:*",
"matchCriteriaId": "97685B5D-843B-4BA4-915C-A384F323A206",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ml110_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D64DCBE5-8590-4F17-A86D-88B78E9E5943",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ml150_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B9876313-D746-4077-A188-F2024C3689F3",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ml30_gen9:2:*:*:*:*:*:*:*",
"matchCriteriaId": "2C53512F-3577-4F64-977C-6579124DA93C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ml350_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1D95AA33-FD84-4766-A42A-4E44A1BC9B8B",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ws460c_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "76D7479C-E340-4E58-A5E5-5AA7C95EE90A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl170r_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6C7DE17C-AC8E-4C0B-B6B1-6D2F4958E70A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl190r_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2838C1A2-23B2-4063-8C16-1558FC329EEB",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl230a_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "40FCFF2E-22B6-4AE3-AE36-B57524656128",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl250a_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CE0AA43F-DEFB-441C-84B8-85F523D600C0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl730f_gen9:*:*:*:*:*:*:*:*",
"matchCriteriaId": "76C1B4FA-E67A-4EB7-A428-FF6C90F0E3B7",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl740f_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3CFED4E5-48AA-4133-A2A2-4D70101593A4",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl750f_gen9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6890F055-67AE-4008-A687-EEAD92D892BD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A remote buffer overflow vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39."
},
{
"lang": "es",
"value": "Fue encontrada una vulnerabilidad de desbordamiento de b\u00fafer remoto en HPE Integrated Lights-Out 4 (iLO 4) anterior a versi\u00f3n 2.61b para servidores Gen9 e Integrated Lights-Out 5 (iLO 5) para servidores Gen10 anteriores a la versi\u00f3n versi\u00f3n 1.39."
}
],
"id": "CVE-2019-11983",
"lastModified": "2024-11-21T04:22:06.370",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 8.5,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.2,
"impactScore": 4.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-06-05T17:29:00.257",
"references": [
{
"source": "security-alert@hpe.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
],
"sourceIdentifier": "security-alert@hpe.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-7117
Vulnerability from fkie_nvd - Published: 2019-04-09 19:29 - Updated: 2024-11-21 04:11
Severity ?
Summary
A remote Cross-Site Scripting in HPE iLO 5 Web User Interface vulnerability was identified in HPE Integrated Lights-Out 5 (iLO 5) for Gen10 ProLiant Servers earlier than version v1.40.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:integrated_lights-out_5_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E0694839-C434-4390-ABBD-A64A4CE3773C",
"versionEndExcluding": "1.40",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BFEC03C5-6E25-47A3-9793-D411056F5D08",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl120_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "43D747DD-AF47-4B5A-B9CC-20BEC97E7788",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl160_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7B0DEA2A-F511-4111-8B33-B029E75D56BF",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl180_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5077B450-1E11-4338-8F76-E4257FBE9260",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl20_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A66883DD-061A-4D0A-A73B-3EF2F7273B83",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl325_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E013812C-A291-4F5E-BA62-B034FA8288ED",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl360_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "45369573-58FC-40E2-8124-08CDEAB6B6C0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl380_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1F5D074B-079C-4227-A2A5-654BB35E7DC3",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl385_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F0766C25-5149-4A02-BC12-38D21EAE2303",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl560_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D894E6C9-D248-4800-A138-CD0FE8F6B5B9",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl580_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8FEBB303-F21A-47FF-9D79-5CBC90144782",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_microserver_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2D8F597A-DBF1-4CA5-9B10-990571E2A968",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ml110_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DA54BDB5-28DF-46D6-8D7D-F2F4F3B21381",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ml30_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EFE18D61-BC0A-414F-A099-549D203C4EBE",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ml350_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7FF6A55B-05B4-4286-BF06-45D2A21EF58F",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A6662F50-79E8-4675-ABAB-E95C7B8A2BBB",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0D33F488-C5DB-40A7-BCAB-4DA1A6FC0096",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "85739B50-AA18-4097-8EAA-3A750EE38AE6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl450_gen10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2C2B30A8-303D-4A47-8D9A-7088F82D2BA3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A remote Cross-Site Scripting in HPE iLO 5 Web User Interface vulnerability was identified in HPE Integrated Lights-Out 5 (iLO 5) for Gen10 ProLiant Servers earlier than version v1.40."
},
{
"lang": "es",
"value": "Se identific\u00f3 una vulnerabilidad del tipo remote cross-site scripting en la Web User Interface de HPE iLO 5 en HPE Integrated Lights-Out 5 (iLO 5) para los servidores ProLiant Gen10 anteriores a la versi\u00f3n v1.40."
}
],
"id": "CVE-2018-7117",
"lastModified": "2024-11-21T04:11:40.383",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-04-09T19:29:01.633",
"references": [
{
"source": "security-alert@hpe.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03907en_us"
},
{
"source": "security-alert@hpe.com",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03907en_us"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
],
"sourceIdentifier": "security-alert@hpe.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-7113
Vulnerability from fkie_nvd - Published: 2018-12-03 15:29 - Updated: 2024-11-21 04:11
Severity ?
Summary
A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) prior to v1.37 could be locally exploited to bypass the security restrictions for firmware updates.
References
| URL | Tags | ||
|---|---|---|---|
| security-alert@hpe.com | http://www.securitytracker.com/id/1042010 | Third Party Advisory, VDB Entry | |
| security-alert@hpe.com | https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03894en_us | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securitytracker.com/id/1042010 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03894en_us | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| hp | integrated_lights-out_5_firmware | * | |
| hp | gen_10_servers | - | |
| hp | integrated_lights-out | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:integrated_lights-out_5_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7D666092-BFB7-4661-83E4-455623142498",
"versionEndExcluding": "1.37",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:gen_10_servers:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C02D0550-99AE-4E94-A799-498FB51CA5D0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:integrated_lights-out:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5F3BB462-1E25-4D84-ABC6-68F6762D719D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) prior to v1.37 could be locally exploited to bypass the security restrictions for firmware updates."
},
{
"lang": "es",
"value": "Una vulnerabilidad de seguridad en HPE Integrated Lights-Out 5 (iLO 5) en versiones anteriores a la v1.37 podr\u00eda explotarse localmente para omitir las restricciones de seguridad para las actualizaciones de firmware."
}
],
"id": "CVE-2018-7113",
"lastModified": "2024-11-21T04:11:39.947",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 0.7,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-12-03T15:29:00.620",
"references": [
{
"source": "security-alert@hpe.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1042010"
},
{
"source": "security-alert@hpe.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03894en_us"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1042010"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03894en_us"
}
],
"sourceIdentifier": "security-alert@hpe.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-7105
Vulnerability from fkie_nvd - Published: 2018-09-27 18:29 - Updated: 2024-11-21 04:11
Severity ?
Summary
A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90 could be remotely exploited to execute arbitrary code leading to disclosure of information.
References
| URL | Tags | ||
|---|---|---|---|
| security-alert@hpe.com | http://www.securityfocus.com/bid/105425 | Third Party Advisory, VDB Entry | |
| security-alert@hpe.com | http://www.securitytracker.com/id/1041649 | Third Party Advisory, VDB Entry | |
| security-alert@hpe.com | https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03866en_us | Mitigation, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/105425 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securitytracker.com/id/1041649 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03866en_us | Mitigation, Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| hp | integrated_lights-out_5_firmware | * | |
| hp | gen_10_servers | - | |
| hp | integrated_lights-out | - | |
| hp | integrated_lights-out_3_firmware | * | |
| hp | integrated_lights-out_4_firmware | * | |
| hp | integrated_lights-out | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:integrated_lights-out_5_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E18AA81A-3F96-4F12-8BBA-A2A3282E891C",
"versionEndExcluding": "1.35",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:gen_10_servers:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C02D0550-99AE-4E94-A799-498FB51CA5D0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:integrated_lights-out:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5F3BB462-1E25-4D84-ABC6-68F6762D719D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:integrated_lights-out_3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "39BA27DF-3771-436C-8812-708720508383",
"versionEndExcluding": "1.90",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hp:integrated_lights-out_4_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5286861C-4CE8-465F-8D31-84ACCC91DA9F",
"versionEndExcluding": "2.61",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:integrated_lights-out:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5F3BB462-1E25-4D84-ABC6-68F6762D719D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90 could be remotely exploited to execute arbitrary code leading to disclosure of information."
},
{
"lang": "es",
"value": "Podr\u00eda explotarse remotamente una vulnerabilidad de seguridad en HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10 en versiones anteriores a la v1.35, HPE Integrated Lights-Out 4 (iLO 4) en versiones anteriores a la v2.61 y HPE Integrated Lights-Out 3 (iLO 3) en versiones anteriores a la v1.90 para ejecutar c\u00f3digo arbitrario, lo que conduce a una divulgaci\u00f3n de informaci\u00f3n."
}
],
"id": "CVE-2018-7105",
"lastModified": "2024-11-21T04:11:39.143",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-09-27T18:29:00.800",
"references": [
{
"source": "security-alert@hpe.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/105425"
},
{
"source": "security-alert@hpe.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1041649"
},
{
"source": "security-alert@hpe.com",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03866en_us"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/105425"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1041649"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03866en_us"
}
],
"sourceIdentifier": "security-alert@hpe.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-7101
Vulnerability from fkie_nvd - Published: 2018-09-27 18:29 - Updated: 2024-11-21 04:11
Severity ?
Summary
A potential remote denial of service security vulnerability has been identified in HPE Integrated Lights Out 4 prior to v2.60 and iLO 5 for Gen 10 servers prior to v1.30.
References
| URL | Tags | ||
|---|---|---|---|
| security-alert@hpe.com | http://www.securitytracker.com/id/1041488 | Third Party Advisory, VDB Entry | |
| security-alert@hpe.com | https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03875en_us | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securitytracker.com/id/1041488 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03875en_us | Vendor Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:integrated_lights-out_4_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "51CA4C93-C4D6-49BC-948D-7E42BC559C73",
"versionEndExcluding": "2.60",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:integrated_lights-out:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5F3BB462-1E25-4D84-ABC6-68F6762D719D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:integrated_lights-out_5_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9FE38E85-0260-4E6D-AD50-37C51FF1CA9E",
"versionEndExcluding": "1.30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2BC485A0-1B3E-4499-AF26-C832330E99BB",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A potential remote denial of service security vulnerability has been identified in HPE Integrated Lights Out 4 prior to v2.60 and iLO 5 for Gen 10 servers prior to v1.30."
},
{
"lang": "es",
"value": "Se ha identificado una potencial vulnerabilidad de seguridad de denegaci\u00f3n de servicio (DoS) remoto en HPE Integrated Lights Out 4 en versiones anteriores a la v2.60 e iLO 5 para servidores Gen 10 en versiones anteriores a la v1.30."
}
],
"id": "CVE-2018-7101",
"lastModified": "2024-11-21T04:11:38.753",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-09-27T18:29:00.300",
"references": [
{
"source": "security-alert@hpe.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1041488"
},
{
"source": "security-alert@hpe.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03875en_us"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1041488"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03875en_us"
}
],
"sourceIdentifier": "security-alert@hpe.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-7093
Vulnerability from fkie_nvd - Published: 2018-08-14 14:29 - Updated: 2024-11-21 04:11
Severity ?
Summary
A security vulnerability in HPE Integrated Lights-Out 3 prior to v1.90, iLO 4 prior to v2.60, iLO 5 prior to v1.30, Moonshot Chassis Manager firmware prior to v1.58, and Moonshot Component Pack prior to v2.55 could be remotely exploited to create a denial of service.
References
| URL | Tags | ||
|---|---|---|---|
| security-alert@hpe.com | http://www.securitytracker.com/id/1041435 | Third Party Advisory, VDB Entry | |
| security-alert@hpe.com | https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03835en_us | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securitytracker.com/id/1041435 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03835en_us | Vendor Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:integrated_lights-out_3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "39BA27DF-3771-436C-8812-708720508383",
"versionEndExcluding": "1.90",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hp:integrated_lights-out_4_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "51CA4C93-C4D6-49BC-948D-7E42BC559C73",
"versionEndExcluding": "2.60",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hp:integrated_lights-out_5_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9FE38E85-0260-4E6D-AD50-37C51FF1CA9E",
"versionEndExcluding": "1.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hp:moonshot_chassis_manager_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "43234882-5295-4648-BFBC-99F742104F29",
"versionEndExcluding": "1.58",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:integrated_lights-out:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5F3BB462-1E25-4D84-ABC6-68F6762D719D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:moonshot_component_pack_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "433C9066-49CC-4CC1-82E7-463C613E2FD6",
"versionEndExcluding": "2.55",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:moonshot_component_pack:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4FEDD2CE-C8A2-40E5-B9A2-1CB9B2B8881D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability in HPE Integrated Lights-Out 3 prior to v1.90, iLO 4 prior to v2.60, iLO 5 prior to v1.30, Moonshot Chassis Manager firmware prior to v1.58, and Moonshot Component Pack prior to v2.55 could be remotely exploited to create a denial of service."
},
{
"lang": "es",
"value": "Una vulnerabilidad de seguridad en HPE Integrated Lights-Out 3 en versiones anteriores a la v1.90, iLO 4 en versiones anteriores a la v2.60, iLO 5 en versiones anteriores a la v1.30, Moonshot Chassis Manager con firmware en versiones anteriores a la v1.58 y Moonshot Component Pack en versiones anteriores a la v2.55 podr\u00eda explotarse de forma remota para crear una denegaci\u00f3n de servicio (DoS)."
}
],
"id": "CVE-2018-7093",
"lastModified": "2024-11-21T04:11:37.953",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 4.0,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-08-14T14:29:00.510",
"references": [
{
"source": "security-alert@hpe.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1041435"
},
{
"source": "security-alert@hpe.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03835en_us"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1041435"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03835en_us"
}
],
"sourceIdentifier": "security-alert@hpe.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-7078
Vulnerability from fkie_nvd - Published: 2018-08-06 20:29 - Updated: 2024-11-21 04:11
Severity ?
Summary
A remote code execution was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than version v2.60 and HPE Integrated Lights-Out 5 (iLO 5) earlier than version v1.30.
References
| URL | Tags | ||
|---|---|---|---|
| security-alert@hpe.com | http://www.securitytracker.com/id/1041188 | Third Party Advisory, VDB Entry | |
| security-alert@hpe.com | https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03844en_us | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securitytracker.com/id/1041188 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03844en_us | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| hp | integrated_lights-out_4_firmware | * | |
| hp | integrated_lights-out_5_firmware | * | |
| hp | integrated_lights-out | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hp:integrated_lights-out_4_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "51CA4C93-C4D6-49BC-948D-7E42BC559C73",
"versionEndExcluding": "2.60",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hp:integrated_lights-out_5_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9FE38E85-0260-4E6D-AD50-37C51FF1CA9E",
"versionEndExcluding": "1.30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hp:integrated_lights-out:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5F3BB462-1E25-4D84-ABC6-68F6762D719D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A remote code execution was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than version v2.60 and HPE Integrated Lights-Out 5 (iLO 5) earlier than version v1.30."
},
{
"lang": "es",
"value": "Se ha identificado una ejecuci\u00f3n remota de c\u00f3digo en HPE Integrated Lights-Out 4 (iLO 4) anteriores a la v2.60 y HPE Integrated Lights-Out 5 (iLO 5) anteriores a la v1.30."
}
],
"id": "CVE-2018-7078",
"lastModified": "2024-11-21T04:11:36.797",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-08-06T20:29:02.163",
"references": [
{
"source": "security-alert@hpe.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1041188"
},
{
"source": "security-alert@hpe.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03844en_us"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1041188"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03844en_us"
}
],
"sourceIdentifier": "security-alert@hpe.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2021-46846 (GCVE-0-2021-46846)
Vulnerability from cvelistv5 – Published: 2022-11-03 16:06 – Updated: 2025-05-02 19:31
VLAI?
Summary
Cross Site Scripting vulnerability in Hewlett Packard Enterprise Integrated Lights-Out 5.
Severity ?
6.4 (Medium)
CWE
- n/a
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise (HPE) | HPE Integrated Lights-Out 5 |
Affected:
Prior to 2.44
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T05:17:42.707Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04133en_us"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-46846",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-02T19:30:52.471405Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-02T19:31:06.168Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "HPE Integrated Lights-Out 5",
"vendor": "Hewlett Packard Enterprise (HPE)",
"versions": [
{
"status": "affected",
"version": "Prior to 2.44"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCross Site Scripting vulnerability in Hewlett Packard Enterprise Integrated Lights-Out 5.\u003c/p\u003e"
}
],
"value": "Cross Site Scripting vulnerability in Hewlett Packard Enterprise Integrated Lights-Out 5.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-12T12:11:04.548Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04133en_us"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2021-46846",
"datePublished": "2022-11-03T16:06:09.815Z",
"dateReserved": "2022-10-19T21:27:41.176Z",
"dateUpdated": "2025-05-02T19:31:06.168Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-11983 (GCVE-0-2019-11983)
Vulnerability from cvelistv5 – Published: 2019-06-05 16:36 – Updated: 2024-08-04 23:10
VLAI?
Summary
A remote buffer overflow vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39.
Severity ?
No CVSS data available.
CWE
- remote buffer overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | HPE iLO4 and HPE iLO5 |
Affected:
iLO4 prior to v2.61b and iLO5 prior to v1.39
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:10:29.947Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE iLO4 and HPE iLO5",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "iLO4 prior to v2.61b and iLO5 prior to v1.39"
}
]
}
],
"datePublic": "2019-05-17T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A remote buffer overflow vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote buffer overflow",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-05T16:36:07",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2019-11983",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE iLO4 and HPE iLO5",
"version": {
"version_data": [
{
"version_value": "iLO4 prior to v2.61b and iLO5 prior to v1.39"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A remote buffer overflow vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote buffer overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2019-11983",
"datePublished": "2019-06-05T16:36:07",
"dateReserved": "2019-05-13T00:00:00",
"dateUpdated": "2024-08-04T23:10:29.947Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-11982 (GCVE-0-2019-11982)
Vulnerability from cvelistv5 – Published: 2019-06-05 16:35 – Updated: 2024-08-04 23:10
VLAI?
Summary
A remote cross site scripting vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39.
Severity ?
No CVSS data available.
CWE
- cross site scripting
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | HPE iLO4 and HPE iLO5 |
Affected:
iLO4 prior to v2.61b and iLO5 prior to v1.39
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:10:29.994Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE iLO4 and HPE iLO5",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "iLO4 prior to v2.61b and iLO5 prior to v1.39"
}
]
}
],
"datePublic": "2019-05-17T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A remote cross site scripting vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "cross site scripting",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-05T16:35:10",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2019-11982",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE iLO4 and HPE iLO5",
"version": {
"version_data": [
{
"version_value": "iLO4 prior to v2.61b and iLO5 prior to v1.39"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A remote cross site scripting vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "cross site scripting"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2019-11982",
"datePublished": "2019-06-05T16:35:10",
"dateReserved": "2019-05-13T00:00:00",
"dateUpdated": "2024-08-04T23:10:29.994Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7117 (GCVE-0-2018-7117)
Vulnerability from cvelistv5 – Published: 2019-04-09 18:28 – Updated: 2024-08-05 06:17
VLAI?
Summary
A remote Cross-Site Scripting in HPE iLO 5 Web User Interface vulnerability was identified in HPE Integrated Lights-Out 5 (iLO 5) for Gen10 ProLiant Servers earlier than version v1.40.
Severity ?
No CVSS data available.
CWE
- remote cross-site scripting
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers |
Affected:
iLO5 prior to v1.40
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:17:17.554Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03907en_us"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "iLO5 prior to v1.40"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A remote Cross-Site Scripting in HPE iLO 5 Web User Interface vulnerability was identified in HPE Integrated Lights-Out 5 (iLO 5) for Gen10 ProLiant Servers earlier than version v1.40."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote cross-site scripting",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-17T21:06:05",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03907en_us"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2018-7117",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
"version": {
"version_data": [
{
"version_value": "iLO5 prior to v1.40"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A remote Cross-Site Scripting in HPE iLO 5 Web User Interface vulnerability was identified in HPE Integrated Lights-Out 5 (iLO 5) for Gen10 ProLiant Servers earlier than version v1.40."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote cross-site scripting"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03907en_us",
"refsource": "MISC",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03907en_us"
},
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2018-7117",
"datePublished": "2019-04-09T18:28:18",
"dateReserved": "2018-02-15T00:00:00",
"dateUpdated": "2024-08-05T06:17:17.554Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7113 (GCVE-0-2018-7113)
Vulnerability from cvelistv5 – Published: 2018-12-03 15:00 – Updated: 2024-08-05 06:17
VLAI?
Summary
A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) prior to v1.37 could be locally exploited to bypass the security restrictions for firmware updates.
Severity ?
No CVSS data available.
CWE
- local bypass of security restrictions
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise | HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers |
Affected:
iLO 5 for HPE Gen10 Servers - Prior to v1.37
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:17:17.569Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "1042010",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1042010"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03894en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
"vendor": "Hewlett Packard Enterprise",
"versions": [
{
"status": "affected",
"version": "iLO 5 for HPE Gen10 Servers - Prior to v1.37"
}
]
}
],
"datePublic": "2018-12-03T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) prior to v1.37 could be locally exploited to bypass the security restrictions for firmware updates."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "local bypass of security restrictions",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-12-04T10:57:01",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"name": "1042010",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1042010"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03894en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2018-7113",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
"version": {
"version_data": [
{
"version_value": "iLO 5 for HPE Gen10 Servers - Prior to v1.37"
}
]
}
}
]
},
"vendor_name": "Hewlett Packard Enterprise"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) prior to v1.37 could be locally exploited to bypass the security restrictions for firmware updates."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "local bypass of security restrictions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "1042010",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1042010"
},
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03894en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03894en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2018-7113",
"datePublished": "2018-12-03T15:00:00",
"dateReserved": "2018-02-15T00:00:00",
"dateUpdated": "2024-08-05T06:17:17.569Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7101 (GCVE-0-2018-7101)
Vulnerability from cvelistv5 – Published: 2018-09-27 18:00 – Updated: 2024-08-05 06:17
VLAI?
Summary
A potential remote denial of service security vulnerability has been identified in HPE Integrated Lights Out 4 prior to v2.60 and iLO 5 for Gen 10 servers prior to v1.30.
Severity ?
No CVSS data available.
CWE
- remote denial of service
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise | HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers, HPE Integrated Lights-Out 4 (iLO 4) |
Affected:
iLO 4 prior to v2.26, iLO5 prior to v1.30
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:17:17.501Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "1041488",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1041488"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03875en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers, HPE Integrated Lights-Out 4 (iLO 4)",
"vendor": "Hewlett Packard Enterprise",
"versions": [
{
"status": "affected",
"version": "iLO 4 prior to v2.26, iLO5 prior to v1.30"
}
]
}
],
"datePublic": "2018-08-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A potential remote denial of service security vulnerability has been identified in HPE Integrated Lights Out 4 prior to v2.60 and iLO 5 for Gen 10 servers prior to v1.30."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote denial of service",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-09-28T09:57:01",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"name": "1041488",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1041488"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03875en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2018-7101",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers, HPE Integrated Lights-Out 4 (iLO 4)",
"version": {
"version_data": [
{
"version_value": "iLO 4 prior to v2.26, iLO5 prior to v1.30"
}
]
}
}
]
},
"vendor_name": "Hewlett Packard Enterprise"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A potential remote denial of service security vulnerability has been identified in HPE Integrated Lights Out 4 prior to v2.60 and iLO 5 for Gen 10 servers prior to v1.30."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote denial of service"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "1041488",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1041488"
},
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03875en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03875en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2018-7101",
"datePublished": "2018-09-27T18:00:00",
"dateReserved": "2018-02-15T00:00:00",
"dateUpdated": "2024-08-05T06:17:17.501Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7105 (GCVE-0-2018-7105)
Vulnerability from cvelistv5 – Published: 2018-09-27 18:00 – Updated: 2024-08-05 06:17
VLAI?
Summary
A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90 could be remotely exploited to execute arbitrary code leading to disclosure of information.
Severity ?
No CVSS data available.
CWE
- remote execution of arbitrary code
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise | HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers, HPE Integrated Lights-Out 4 (iLO 4), HPE Integrated Lights-Out 3 (iLO 3) |
Affected:
HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:17:17.562Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "105425",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105425"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03866en_us"
},
{
"name": "1041649",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1041649"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers, HPE Integrated Lights-Out 4 (iLO 4), HPE Integrated Lights-Out 3 (iLO 3)",
"vendor": "Hewlett Packard Enterprise",
"versions": [
{
"status": "affected",
"version": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90"
}
]
}
],
"datePublic": "2018-09-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90 could be remotely exploited to execute arbitrary code leading to disclosure of information."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote execution of arbitrary code",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-10-18T17:57:01",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"name": "105425",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105425"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03866en_us"
},
{
"name": "1041649",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1041649"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2018-7105",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers, HPE Integrated Lights-Out 4 (iLO 4), HPE Integrated Lights-Out 3 (iLO 3)",
"version": {
"version_data": [
{
"version_value": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90"
}
]
}
}
]
},
"vendor_name": "Hewlett Packard Enterprise"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90 could be remotely exploited to execute arbitrary code leading to disclosure of information."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote execution of arbitrary code"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "105425",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105425"
},
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03866en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03866en_us"
},
{
"name": "1041649",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1041649"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2018-7105",
"datePublished": "2018-09-27T18:00:00",
"dateReserved": "2018-02-15T00:00:00",
"dateUpdated": "2024-08-05T06:17:17.562Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7093 (GCVE-0-2018-7093)
Vulnerability from cvelistv5 – Published: 2018-08-14 14:00 – Updated: 2024-08-05 06:17
VLAI?
Summary
A security vulnerability in HPE Integrated Lights-Out 3 prior to v1.90, iLO 4 prior to v2.60, iLO 5 prior to v1.30, Moonshot Chassis Manager firmware prior to v1.58, and Moonshot Component Pack prior to v2.55 could be remotely exploited to create a denial of service.
Severity ?
No CVSS data available.
CWE
- remote denial of service
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise | iLO 5 for HPE Gen10 Servers, iLO 4, iLO 3, Moonshot Chassis Management Firmware, Moonshot Component Packs for HPE ProLiant m510 and m710x server cartridges |
Affected:
iLO 5 for HPE Gen10 Servers - Prior to v1.30, iLO 4 - Prior to v2.60, iLO 3 - Prior to v1.90, Moonshot Chassis Management Firmware - Prior to 1.58, Moonshot Component Packs - Prior to 2.55 for HPE ProLiant m510 and m710x server cartridges
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:17:17.590Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "1041435",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1041435"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03835en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "iLO 5 for HPE Gen10 Servers, iLO 4, iLO 3, Moonshot Chassis Management Firmware, Moonshot Component Packs for HPE ProLiant m510 and m710x server cartridges",
"vendor": "Hewlett Packard Enterprise",
"versions": [
{
"status": "affected",
"version": "iLO 5 for HPE Gen10 Servers - Prior to v1.30, iLO 4 - Prior to v2.60, iLO 3 - Prior to v1.90, Moonshot Chassis Management Firmware - Prior to 1.58, Moonshot Component Packs - Prior to 2.55 for HPE ProLiant m510 and m710x server cartridges"
}
]
}
],
"datePublic": "2018-08-07T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability in HPE Integrated Lights-Out 3 prior to v1.90, iLO 4 prior to v2.60, iLO 5 prior to v1.30, Moonshot Chassis Manager firmware prior to v1.58, and Moonshot Component Pack prior to v2.55 could be remotely exploited to create a denial of service."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote denial of service",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-15T09:57:01",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"name": "1041435",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1041435"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03835en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2018-7093",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "iLO 5 for HPE Gen10 Servers, iLO 4, iLO 3, Moonshot Chassis Management Firmware, Moonshot Component Packs for HPE ProLiant m510 and m710x server cartridges",
"version": {
"version_data": [
{
"version_value": "iLO 5 for HPE Gen10 Servers - Prior to v1.30, iLO 4 - Prior to v2.60, iLO 3 - Prior to v1.90, Moonshot Chassis Management Firmware - Prior to 1.58, Moonshot Component Packs - Prior to 2.55 for HPE ProLiant m510 and m710x server cartridges"
}
]
}
}
]
},
"vendor_name": "Hewlett Packard Enterprise"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A security vulnerability in HPE Integrated Lights-Out 3 prior to v1.90, iLO 4 prior to v2.60, iLO 5 prior to v1.30, Moonshot Chassis Manager firmware prior to v1.58, and Moonshot Component Pack prior to v2.55 could be remotely exploited to create a denial of service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote denial of service"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "1041435",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1041435"
},
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03835en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03835en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2018-7093",
"datePublished": "2018-08-14T14:00:00",
"dateReserved": "2018-02-15T00:00:00",
"dateUpdated": "2024-08-05T06:17:17.590Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7078 (GCVE-0-2018-7078)
Vulnerability from cvelistv5 – Published: 2018-08-06 20:00 – Updated: 2024-08-05 06:17
VLAI?
Summary
A remote code execution was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than version v2.60 and HPE Integrated Lights-Out 5 (iLO 5) earlier than version v1.30.
Severity ?
No CVSS data available.
CWE
- remote code execution
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise | HPE Integrated Lights-Out 4 (iLO 4), HPE Integrated Lights-Out 5 (iLO 5) |
Affected:
iLO 4 earlier than version v2.60, iLO 5 earlier than version v1.30
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:17:17.478Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03844en_us"
},
{
"name": "1041188",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1041188"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE Integrated Lights-Out 4 (iLO 4), HPE Integrated Lights-Out 5 (iLO 5)",
"vendor": "Hewlett Packard Enterprise",
"versions": [
{
"status": "affected",
"version": "iLO 4 earlier than version v2.60, iLO 5 earlier than version v1.30"
}
]
}
],
"datePublic": "2018-06-26T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A remote code execution was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than version v2.60 and HPE Integrated Lights-Out 5 (iLO 5) earlier than version v1.30."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote code execution",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-07T09:57:01",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03844en_us"
},
{
"name": "1041188",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1041188"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2018-7078",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE Integrated Lights-Out 4 (iLO 4), HPE Integrated Lights-Out 5 (iLO 5)",
"version": {
"version_data": [
{
"version_value": "iLO 4 earlier than version v2.60, iLO 5 earlier than version v1.30"
}
]
}
}
]
},
"vendor_name": "Hewlett Packard Enterprise"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A remote code execution was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than version v2.60 and HPE Integrated Lights-Out 5 (iLO 5) earlier than version v1.30."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote code execution"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03844en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03844en_us"
},
{
"name": "1041188",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1041188"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2018-7078",
"datePublished": "2018-08-06T20:00:00",
"dateReserved": "2018-02-15T00:00:00",
"dateUpdated": "2024-08-05T06:17:17.478Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-46846 (GCVE-0-2021-46846)
Vulnerability from nvd – Published: 2022-11-03 16:06 – Updated: 2025-05-02 19:31
VLAI?
Summary
Cross Site Scripting vulnerability in Hewlett Packard Enterprise Integrated Lights-Out 5.
Severity ?
6.4 (Medium)
CWE
- n/a
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise (HPE) | HPE Integrated Lights-Out 5 |
Affected:
Prior to 2.44
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T05:17:42.707Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04133en_us"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-46846",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-02T19:30:52.471405Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-02T19:31:06.168Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "HPE Integrated Lights-Out 5",
"vendor": "Hewlett Packard Enterprise (HPE)",
"versions": [
{
"status": "affected",
"version": "Prior to 2.44"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCross Site Scripting vulnerability in Hewlett Packard Enterprise Integrated Lights-Out 5.\u003c/p\u003e"
}
],
"value": "Cross Site Scripting vulnerability in Hewlett Packard Enterprise Integrated Lights-Out 5.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-12T12:11:04.548Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04133en_us"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2021-46846",
"datePublished": "2022-11-03T16:06:09.815Z",
"dateReserved": "2022-10-19T21:27:41.176Z",
"dateUpdated": "2025-05-02T19:31:06.168Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-11983 (GCVE-0-2019-11983)
Vulnerability from nvd – Published: 2019-06-05 16:36 – Updated: 2024-08-04 23:10
VLAI?
Summary
A remote buffer overflow vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39.
Severity ?
No CVSS data available.
CWE
- remote buffer overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | HPE iLO4 and HPE iLO5 |
Affected:
iLO4 prior to v2.61b and iLO5 prior to v1.39
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:10:29.947Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE iLO4 and HPE iLO5",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "iLO4 prior to v2.61b and iLO5 prior to v1.39"
}
]
}
],
"datePublic": "2019-05-17T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A remote buffer overflow vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote buffer overflow",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-05T16:36:07",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2019-11983",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE iLO4 and HPE iLO5",
"version": {
"version_data": [
{
"version_value": "iLO4 prior to v2.61b and iLO5 prior to v1.39"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A remote buffer overflow vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote buffer overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2019-11983",
"datePublished": "2019-06-05T16:36:07",
"dateReserved": "2019-05-13T00:00:00",
"dateUpdated": "2024-08-04T23:10:29.947Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-11982 (GCVE-0-2019-11982)
Vulnerability from nvd – Published: 2019-06-05 16:35 – Updated: 2024-08-04 23:10
VLAI?
Summary
A remote cross site scripting vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39.
Severity ?
No CVSS data available.
CWE
- cross site scripting
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | HPE iLO4 and HPE iLO5 |
Affected:
iLO4 prior to v2.61b and iLO5 prior to v1.39
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:10:29.994Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE iLO4 and HPE iLO5",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "iLO4 prior to v2.61b and iLO5 prior to v1.39"
}
]
}
],
"datePublic": "2019-05-17T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A remote cross site scripting vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "cross site scripting",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-05T16:35:10",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2019-11982",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE iLO4 and HPE iLO5",
"version": {
"version_data": [
{
"version_value": "iLO4 prior to v2.61b and iLO5 prior to v1.39"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A remote cross site scripting vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "cross site scripting"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2019-11982",
"datePublished": "2019-06-05T16:35:10",
"dateReserved": "2019-05-13T00:00:00",
"dateUpdated": "2024-08-04T23:10:29.994Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7117 (GCVE-0-2018-7117)
Vulnerability from nvd – Published: 2019-04-09 18:28 – Updated: 2024-08-05 06:17
VLAI?
Summary
A remote Cross-Site Scripting in HPE iLO 5 Web User Interface vulnerability was identified in HPE Integrated Lights-Out 5 (iLO 5) for Gen10 ProLiant Servers earlier than version v1.40.
Severity ?
No CVSS data available.
CWE
- remote cross-site scripting
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers |
Affected:
iLO5 prior to v1.40
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:17:17.554Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03907en_us"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "iLO5 prior to v1.40"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A remote Cross-Site Scripting in HPE iLO 5 Web User Interface vulnerability was identified in HPE Integrated Lights-Out 5 (iLO 5) for Gen10 ProLiant Servers earlier than version v1.40."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote cross-site scripting",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-17T21:06:05",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03907en_us"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2018-7117",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
"version": {
"version_data": [
{
"version_value": "iLO5 prior to v1.40"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A remote Cross-Site Scripting in HPE iLO 5 Web User Interface vulnerability was identified in HPE Integrated Lights-Out 5 (iLO 5) for Gen10 ProLiant Servers earlier than version v1.40."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote cross-site scripting"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03907en_us",
"refsource": "MISC",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03907en_us"
},
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2018-7117",
"datePublished": "2019-04-09T18:28:18",
"dateReserved": "2018-02-15T00:00:00",
"dateUpdated": "2024-08-05T06:17:17.554Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7113 (GCVE-0-2018-7113)
Vulnerability from nvd – Published: 2018-12-03 15:00 – Updated: 2024-08-05 06:17
VLAI?
Summary
A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) prior to v1.37 could be locally exploited to bypass the security restrictions for firmware updates.
Severity ?
No CVSS data available.
CWE
- local bypass of security restrictions
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise | HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers |
Affected:
iLO 5 for HPE Gen10 Servers - Prior to v1.37
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:17:17.569Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "1042010",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1042010"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03894en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
"vendor": "Hewlett Packard Enterprise",
"versions": [
{
"status": "affected",
"version": "iLO 5 for HPE Gen10 Servers - Prior to v1.37"
}
]
}
],
"datePublic": "2018-12-03T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) prior to v1.37 could be locally exploited to bypass the security restrictions for firmware updates."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "local bypass of security restrictions",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-12-04T10:57:01",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"name": "1042010",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1042010"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03894en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2018-7113",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
"version": {
"version_data": [
{
"version_value": "iLO 5 for HPE Gen10 Servers - Prior to v1.37"
}
]
}
}
]
},
"vendor_name": "Hewlett Packard Enterprise"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) prior to v1.37 could be locally exploited to bypass the security restrictions for firmware updates."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "local bypass of security restrictions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "1042010",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1042010"
},
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03894en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03894en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2018-7113",
"datePublished": "2018-12-03T15:00:00",
"dateReserved": "2018-02-15T00:00:00",
"dateUpdated": "2024-08-05T06:17:17.569Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7101 (GCVE-0-2018-7101)
Vulnerability from nvd – Published: 2018-09-27 18:00 – Updated: 2024-08-05 06:17
VLAI?
Summary
A potential remote denial of service security vulnerability has been identified in HPE Integrated Lights Out 4 prior to v2.60 and iLO 5 for Gen 10 servers prior to v1.30.
Severity ?
No CVSS data available.
CWE
- remote denial of service
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise | HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers, HPE Integrated Lights-Out 4 (iLO 4) |
Affected:
iLO 4 prior to v2.26, iLO5 prior to v1.30
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:17:17.501Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "1041488",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1041488"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03875en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers, HPE Integrated Lights-Out 4 (iLO 4)",
"vendor": "Hewlett Packard Enterprise",
"versions": [
{
"status": "affected",
"version": "iLO 4 prior to v2.26, iLO5 prior to v1.30"
}
]
}
],
"datePublic": "2018-08-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A potential remote denial of service security vulnerability has been identified in HPE Integrated Lights Out 4 prior to v2.60 and iLO 5 for Gen 10 servers prior to v1.30."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote denial of service",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-09-28T09:57:01",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"name": "1041488",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1041488"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03875en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2018-7101",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers, HPE Integrated Lights-Out 4 (iLO 4)",
"version": {
"version_data": [
{
"version_value": "iLO 4 prior to v2.26, iLO5 prior to v1.30"
}
]
}
}
]
},
"vendor_name": "Hewlett Packard Enterprise"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A potential remote denial of service security vulnerability has been identified in HPE Integrated Lights Out 4 prior to v2.60 and iLO 5 for Gen 10 servers prior to v1.30."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote denial of service"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "1041488",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1041488"
},
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03875en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03875en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2018-7101",
"datePublished": "2018-09-27T18:00:00",
"dateReserved": "2018-02-15T00:00:00",
"dateUpdated": "2024-08-05T06:17:17.501Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7105 (GCVE-0-2018-7105)
Vulnerability from nvd – Published: 2018-09-27 18:00 – Updated: 2024-08-05 06:17
VLAI?
Summary
A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90 could be remotely exploited to execute arbitrary code leading to disclosure of information.
Severity ?
No CVSS data available.
CWE
- remote execution of arbitrary code
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise | HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers, HPE Integrated Lights-Out 4 (iLO 4), HPE Integrated Lights-Out 3 (iLO 3) |
Affected:
HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:17:17.562Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "105425",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105425"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03866en_us"
},
{
"name": "1041649",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1041649"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers, HPE Integrated Lights-Out 4 (iLO 4), HPE Integrated Lights-Out 3 (iLO 3)",
"vendor": "Hewlett Packard Enterprise",
"versions": [
{
"status": "affected",
"version": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90"
}
]
}
],
"datePublic": "2018-09-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90 could be remotely exploited to execute arbitrary code leading to disclosure of information."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote execution of arbitrary code",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-10-18T17:57:01",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"name": "105425",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105425"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03866en_us"
},
{
"name": "1041649",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1041649"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2018-7105",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers, HPE Integrated Lights-Out 4 (iLO 4), HPE Integrated Lights-Out 3 (iLO 3)",
"version": {
"version_data": [
{
"version_value": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90"
}
]
}
}
]
},
"vendor_name": "Hewlett Packard Enterprise"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90 could be remotely exploited to execute arbitrary code leading to disclosure of information."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote execution of arbitrary code"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "105425",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105425"
},
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03866en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03866en_us"
},
{
"name": "1041649",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1041649"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2018-7105",
"datePublished": "2018-09-27T18:00:00",
"dateReserved": "2018-02-15T00:00:00",
"dateUpdated": "2024-08-05T06:17:17.562Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7093 (GCVE-0-2018-7093)
Vulnerability from nvd – Published: 2018-08-14 14:00 – Updated: 2024-08-05 06:17
VLAI?
Summary
A security vulnerability in HPE Integrated Lights-Out 3 prior to v1.90, iLO 4 prior to v2.60, iLO 5 prior to v1.30, Moonshot Chassis Manager firmware prior to v1.58, and Moonshot Component Pack prior to v2.55 could be remotely exploited to create a denial of service.
Severity ?
No CVSS data available.
CWE
- remote denial of service
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise | iLO 5 for HPE Gen10 Servers, iLO 4, iLO 3, Moonshot Chassis Management Firmware, Moonshot Component Packs for HPE ProLiant m510 and m710x server cartridges |
Affected:
iLO 5 for HPE Gen10 Servers - Prior to v1.30, iLO 4 - Prior to v2.60, iLO 3 - Prior to v1.90, Moonshot Chassis Management Firmware - Prior to 1.58, Moonshot Component Packs - Prior to 2.55 for HPE ProLiant m510 and m710x server cartridges
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:17:17.590Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "1041435",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1041435"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03835en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "iLO 5 for HPE Gen10 Servers, iLO 4, iLO 3, Moonshot Chassis Management Firmware, Moonshot Component Packs for HPE ProLiant m510 and m710x server cartridges",
"vendor": "Hewlett Packard Enterprise",
"versions": [
{
"status": "affected",
"version": "iLO 5 for HPE Gen10 Servers - Prior to v1.30, iLO 4 - Prior to v2.60, iLO 3 - Prior to v1.90, Moonshot Chassis Management Firmware - Prior to 1.58, Moonshot Component Packs - Prior to 2.55 for HPE ProLiant m510 and m710x server cartridges"
}
]
}
],
"datePublic": "2018-08-07T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability in HPE Integrated Lights-Out 3 prior to v1.90, iLO 4 prior to v2.60, iLO 5 prior to v1.30, Moonshot Chassis Manager firmware prior to v1.58, and Moonshot Component Pack prior to v2.55 could be remotely exploited to create a denial of service."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote denial of service",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-15T09:57:01",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"name": "1041435",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1041435"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03835en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2018-7093",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "iLO 5 for HPE Gen10 Servers, iLO 4, iLO 3, Moonshot Chassis Management Firmware, Moonshot Component Packs for HPE ProLiant m510 and m710x server cartridges",
"version": {
"version_data": [
{
"version_value": "iLO 5 for HPE Gen10 Servers - Prior to v1.30, iLO 4 - Prior to v2.60, iLO 3 - Prior to v1.90, Moonshot Chassis Management Firmware - Prior to 1.58, Moonshot Component Packs - Prior to 2.55 for HPE ProLiant m510 and m710x server cartridges"
}
]
}
}
]
},
"vendor_name": "Hewlett Packard Enterprise"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A security vulnerability in HPE Integrated Lights-Out 3 prior to v1.90, iLO 4 prior to v2.60, iLO 5 prior to v1.30, Moonshot Chassis Manager firmware prior to v1.58, and Moonshot Component Pack prior to v2.55 could be remotely exploited to create a denial of service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote denial of service"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "1041435",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1041435"
},
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03835en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03835en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2018-7093",
"datePublished": "2018-08-14T14:00:00",
"dateReserved": "2018-02-15T00:00:00",
"dateUpdated": "2024-08-05T06:17:17.590Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7078 (GCVE-0-2018-7078)
Vulnerability from nvd – Published: 2018-08-06 20:00 – Updated: 2024-08-05 06:17
VLAI?
Summary
A remote code execution was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than version v2.60 and HPE Integrated Lights-Out 5 (iLO 5) earlier than version v1.30.
Severity ?
No CVSS data available.
CWE
- remote code execution
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise | HPE Integrated Lights-Out 4 (iLO 4), HPE Integrated Lights-Out 5 (iLO 5) |
Affected:
iLO 4 earlier than version v2.60, iLO 5 earlier than version v1.30
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:17:17.478Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03844en_us"
},
{
"name": "1041188",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1041188"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE Integrated Lights-Out 4 (iLO 4), HPE Integrated Lights-Out 5 (iLO 5)",
"vendor": "Hewlett Packard Enterprise",
"versions": [
{
"status": "affected",
"version": "iLO 4 earlier than version v2.60, iLO 5 earlier than version v1.30"
}
]
}
],
"datePublic": "2018-06-26T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A remote code execution was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than version v2.60 and HPE Integrated Lights-Out 5 (iLO 5) earlier than version v1.30."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote code execution",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-07T09:57:01",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03844en_us"
},
{
"name": "1041188",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1041188"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2018-7078",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE Integrated Lights-Out 4 (iLO 4), HPE Integrated Lights-Out 5 (iLO 5)",
"version": {
"version_data": [
{
"version_value": "iLO 4 earlier than version v2.60, iLO 5 earlier than version v1.30"
}
]
}
}
]
},
"vendor_name": "Hewlett Packard Enterprise"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A remote code execution was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than version v2.60 and HPE Integrated Lights-Out 5 (iLO 5) earlier than version v1.30."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote code execution"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03844en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03844en_us"
},
{
"name": "1041188",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1041188"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2018-7078",
"datePublished": "2018-08-06T20:00:00",
"dateReserved": "2018-02-15T00:00:00",
"dateUpdated": "2024-08-05T06:17:17.478Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}