Search criteria
3 vulnerabilities found for intel_management_engine_firmware_update_utility by dell
FKIE_CVE-2024-38296
Vulnerability from fkie_nvd - Published: 2024-11-22 03:15 - Updated: 2025-02-04 16:05
Severity ?
6.7 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
4.4 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
4.4 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
Summary
Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | intel_management_engine_firmware_update_utility | * | |
| dell | edge_gateway_3200 | - | |
| dell | intel_management_engine_firmware_update_utility | * | |
| dell | edge_gateway_5200 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:intel_management_engine_firmware_update_utility:*:*:*:*:*:*:*:*",
"matchCriteriaId": "995658F4-37C9-478C-B622-02315A6F935F",
"versionEndExcluding": "15.40.30.2879",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dell:edge_gateway_3200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBA59414-5A32-4706-85A5-D5459EE22BA5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:intel_management_engine_firmware_update_utility:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4AEE84CB-69AA-45C3-9414-EB9CE7C21531",
"versionEndExcluding": "12.0.94.2380",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dell:edge_gateway_5200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F6832A53-E950-4572-A178-CF5DC14CACC5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
},
{
"lang": "es",
"value": "Dell Edge Gateway 5200 (Coffee Lake S), versiones anteriores a 12.0.94.2380, contiene una vulnerabilidad de exposici\u00f3n de informaci\u00f3n confidencial en estructuras microarquitect\u00f3nicas compartidas durante la ejecuci\u00f3n transitoria. Un atacante con privilegios elevados y acceso local podr\u00eda aprovechar esta vulnerabilidad, lo que provocar\u00eda la exposici\u00f3n de informaci\u00f3n."
}
],
"id": "CVE-2024-38296",
"lastModified": "2025-02-04T16:05:01.007",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.8,
"impactScore": 5.9,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 0.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2024-11-22T03:15:04.160",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000250949/dsa-2024-345-security-update-for-dell-networking-edge-gateway-5200-vulnerability"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2024-38296 (GCVE-0-2024-38296)
Vulnerability from cvelistv5 – Published: 2024-11-22 02:58 – Updated: 2024-12-09 15:03
VLAI?
Summary
Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.
Severity ?
6.7 (Medium)
CWE
- CWE-1421 - Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Edge Gateway 5200 |
Affected:
N/A , < 12.0.94.2380
(semver)
|
Credits
Dell would like to thank the Eclypsium Research Team for reporting this issue
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:dell:edge_gateway_5200_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "edge_gateway_5200_firmware",
"vendor": "dell",
"versions": [
{
"lessThan": "12.0.94.2380",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-38296",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-25T18:18:21.316783Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-25T18:20:39.113Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Edge Gateway 5200",
"vendor": "Dell",
"versions": [
{
"lessThan": "12.0.94.2380",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank the Eclypsium Research Team for reporting this issue"
}
],
"datePublic": "2024-11-21T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
}
],
"value": "Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1421",
"description": "CWE-1421: Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-09T15:03:06.924Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000250949/dsa-2024-345-security-update-for-dell-networking-edge-gateway-5200-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-38296",
"datePublished": "2024-11-22T02:58:27.660Z",
"dateReserved": "2024-06-13T14:41:01.525Z",
"dateUpdated": "2024-12-09T15:03:06.924Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-38296 (GCVE-0-2024-38296)
Vulnerability from nvd – Published: 2024-11-22 02:58 – Updated: 2024-12-09 15:03
VLAI?
Summary
Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.
Severity ?
6.7 (Medium)
CWE
- CWE-1421 - Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Edge Gateway 5200 |
Affected:
N/A , < 12.0.94.2380
(semver)
|
Credits
Dell would like to thank the Eclypsium Research Team for reporting this issue
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:dell:edge_gateway_5200_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "edge_gateway_5200_firmware",
"vendor": "dell",
"versions": [
{
"lessThan": "12.0.94.2380",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-38296",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-25T18:18:21.316783Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-25T18:20:39.113Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Edge Gateway 5200",
"vendor": "Dell",
"versions": [
{
"lessThan": "12.0.94.2380",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank the Eclypsium Research Team for reporting this issue"
}
],
"datePublic": "2024-11-21T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
}
],
"value": "Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1421",
"description": "CWE-1421: Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-09T15:03:06.924Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000250949/dsa-2024-345-security-update-for-dell-networking-edge-gateway-5200-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-38296",
"datePublished": "2024-11-22T02:58:27.660Z",
"dateReserved": "2024-06-13T14:41:01.525Z",
"dateUpdated": "2024-12-09T15:03:06.924Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}