Search criteria
3 vulnerabilities found for kp303_firmware by tp-link
FKIE_CVE-2025-8627
Vulnerability from fkie_nvd - Published: 2025-08-25 22:15 - Updated: 2025-09-15 14:24
Severity ?
Summary
The TP-Link KP303 Smartplug can be issued unauthenticated protocol commands that may cause unintended power-off condition and potential information leak.
This issue affects TP-Link KP303 (US) Smartplug: before 1.1.0.
References
| URL | Tags | ||
|---|---|---|---|
| f23511db-6c3e-4e32-a477-6aa17d310630 | https://www.tp-link.com/us/support/faq/4619/ | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tp-link | kp303_firmware | * | |
| tp-link | kp303 | 2.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:kp303_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "562BA176-6731-416D-9E2B-B45B9D54D8F8",
"versionEndExcluding": "1.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:kp303:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "A5E4D955-4376-4FDE-ABAE-67807B656953",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The TP-Link KP303 Smartplug\u00a0can be issued unauthenticated protocol commands that may cause unintended power-off condition and potential information leak.\n\nThis issue affects TP-Link KP303 (US) Smartplug: before 1.1.0."
},
{
"lang": "es",
"value": "El TP-Link KP303 Smartplug puede recibir comandos de protocolo no autenticados que pueden provocar un apagado inesperado y una posible fuga de informaci\u00f3n. Este problema afecta al Smartplug TP-Link KP303 (EE. UU.): versiones anteriores a la 1.1.0."
}
],
"id": "CVE-2025-8627",
"lastModified": "2025-09-15T14:24:45.263",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
]
},
"published": "2025-08-25T22:15:33.703",
"references": [
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Vendor Advisory"
],
"url": "https://www.tp-link.com/us/support/faq/4619/"
}
],
"sourceIdentifier": "f23511db-6c3e-4e32-a477-6aa17d310630",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
CVE-2025-8627 (GCVE-0-2025-8627)
Vulnerability from cvelistv5 – Published: 2025-08-25 21:17 – Updated: 2025-08-26 12:58
VLAI?
Summary
The TP-Link KP303 Smartplug can be issued unauthenticated protocol commands that may cause unintended power-off condition and potential information leak.
This issue affects TP-Link KP303 (US) Smartplug: before 1.1.0.
Severity ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| TP-Link Systems Inc. | TP-Link KP303 (US) Smartplug |
Affected:
0 , < 1.1.0
(custom)
|
Credits
Elysee Franchuk of MOBIA Technology Innovations
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-8627",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-26T12:57:25.115168Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-26T12:58:50.832Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TP-Link KP303 (US) Smartplug",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Elysee Franchuk of MOBIA Technology Innovations"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003eThe TP-Link KP303 Smartplug\u0026nbsp;can be issued unauthenticated protocol commands that may cause unintended power-off condition and potential information leak.\u003c/div\u003e\u003cp\u003eThis issue affects TP-Link KP303 (US) Smartplug: before 1.1.0.\u003c/p\u003e"
}
],
"value": "The TP-Link KP303 Smartplug\u00a0can be issued unauthenticated protocol commands that may cause unintended power-off condition and potential information leak.\n\nThis issue affects TP-Link KP303 (US) Smartplug: before 1.1.0."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-25T21:17:04.212Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.tp-link.com/us/support/faq/4619/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Unauthenticated Protocol Commands on TP-Link KP303",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-8627",
"datePublished": "2025-08-25T21:17:04.212Z",
"dateReserved": "2025-08-06T00:21:57.619Z",
"dateUpdated": "2025-08-26T12:58:50.832Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-8627 (GCVE-0-2025-8627)
Vulnerability from nvd – Published: 2025-08-25 21:17 – Updated: 2025-08-26 12:58
VLAI?
Summary
The TP-Link KP303 Smartplug can be issued unauthenticated protocol commands that may cause unintended power-off condition and potential information leak.
This issue affects TP-Link KP303 (US) Smartplug: before 1.1.0.
Severity ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| TP-Link Systems Inc. | TP-Link KP303 (US) Smartplug |
Affected:
0 , < 1.1.0
(custom)
|
Credits
Elysee Franchuk of MOBIA Technology Innovations
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-8627",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-26T12:57:25.115168Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-26T12:58:50.832Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TP-Link KP303 (US) Smartplug",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Elysee Franchuk of MOBIA Technology Innovations"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003eThe TP-Link KP303 Smartplug\u0026nbsp;can be issued unauthenticated protocol commands that may cause unintended power-off condition and potential information leak.\u003c/div\u003e\u003cp\u003eThis issue affects TP-Link KP303 (US) Smartplug: before 1.1.0.\u003c/p\u003e"
}
],
"value": "The TP-Link KP303 Smartplug\u00a0can be issued unauthenticated protocol commands that may cause unintended power-off condition and potential information leak.\n\nThis issue affects TP-Link KP303 (US) Smartplug: before 1.1.0."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-25T21:17:04.212Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.tp-link.com/us/support/faq/4619/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Unauthenticated Protocol Commands on TP-Link KP303",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-8627",
"datePublished": "2025-08-25T21:17:04.212Z",
"dateReserved": "2025-08-06T00:21:57.619Z",
"dateUpdated": "2025-08-26T12:58:50.832Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}