Search criteria

3 vulnerabilities found for mb-secure_pro_firmware by honeywell

FKIE_CVE-2025-2605

Vulnerability from fkie_nvd - Published: 2025-05-02 13:15 - Updated: 2025-05-17 06:15
Summary
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:honeywell:mb-secure_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9A3948BD-0AA0-4F44-87DE-6F93FE58A3CC",
              "versionEndExcluding": "12.53",
              "versionStartIncluding": "11.04",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:honeywell:mb-secure:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "068F05DB-54F1-4F6B-8A1B-501E7841469B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:honeywell:mb-secure_pro_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6782306-FD38-4001-9F99-9B1A9EC820F9",
              "versionEndExcluding": "03.09",
              "versionStartIncluding": "01.06",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:honeywell:mb-secure_pro:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8F28351-A605-4F24-B62B-408D77C661E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product."
    },
    {
      "lang": "es",
      "value": "La vulnerabilidad de neutralizaci\u00f3n incorrecta de elementos especiales utilizados en un comando del sistema operativo (\u0027Inyecci\u00f3n de comandos del sistema operativo\u0027) en Honeywell MB-Secure permite el abuso de privilegios. Este problema afecta a MB-Secure desde la versi\u00f3n 11.04 hasta la 12.53 y a MB-Secure PRO desde la versi\u00f3n 01.06 hasta la 03.09. Honeywell tambi\u00e9n recomienda actualizar a la versi\u00f3n m\u00e1s reciente de este producto."
    }
  ],
  "id": "CVE-2025-2605",
  "lastModified": "2025-05-17T06:15:18.303",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.9,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.1,
        "impactScore": 6.0,
        "source": "psirt@honeywell.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2025-05-02T13:15:46.440",
  "references": [
    {
      "source": "psirt@honeywell.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.honeywell.com/us/en/product-security#security-notices"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://seclists.org/fulldisclosure/2025/May/19"
    }
  ],
  "sourceIdentifier": "psirt@honeywell.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "psirt@honeywell.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2025-2605 (GCVE-0-2025-2605)

Vulnerability from cvelistv5 – Published: 2025-05-02 12:39 – Updated: 2025-05-17 06:03
VLAI?
Summary
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Honeywell MB-Secure Affected: V11.04 , < V12.53 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2605",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-02T13:32:21.228869Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-02T13:32:33.807Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-05-17T06:03:36.347Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/May/19"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "MB-Secure",
          "vendor": "Honeywell",
          "versions": [
            {
              "lessThan": "V12.53",
              "status": "affected",
              "version": "V11.04",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product."
            }
          ],
          "value": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-122",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-122 Privilege Abuse"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-02T12:39:39.979Z",
        "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "shortName": "Honeywell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.honeywell.com/us/en/product-security#security-notices"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Authenticated command injection",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
    "assignerShortName": "Honeywell",
    "cveId": "CVE-2025-2605",
    "datePublished": "2025-05-02T12:39:39.979Z",
    "dateReserved": "2025-03-21T13:18:29.509Z",
    "dateUpdated": "2025-05-17T06:03:36.347Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2605 (GCVE-0-2025-2605)

Vulnerability from nvd – Published: 2025-05-02 12:39 – Updated: 2025-05-17 06:03
VLAI?
Summary
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Honeywell MB-Secure Affected: V11.04 , < V12.53 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2605",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-02T13:32:21.228869Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-02T13:32:33.807Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-05-17T06:03:36.347Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/May/19"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "MB-Secure",
          "vendor": "Honeywell",
          "versions": [
            {
              "lessThan": "V12.53",
              "status": "affected",
              "version": "V11.04",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product."
            }
          ],
          "value": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-122",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-122 Privilege Abuse"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-02T12:39:39.979Z",
        "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "shortName": "Honeywell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.honeywell.com/us/en/product-security#security-notices"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Authenticated command injection",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
    "assignerShortName": "Honeywell",
    "cveId": "CVE-2025-2605",
    "datePublished": "2025-05-02T12:39:39.979Z",
    "dateReserved": "2025-03-21T13:18:29.509Z",
    "dateUpdated": "2025-05-17T06:03:36.347Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}