CVE-2026-4272 (GCVE-0-2026-4272)
Vulnerability from nvd – Published: 2026-04-05 22:00 – Updated: 2026-04-06 14:01
VLAI
Title
CVE-2026-4272 - Bluetooth Remote Execution of System Commands Vulnerability
Summary
Missing Authentication for Critical Function vulnerability in Honeywell Handheld Scanners allows Authentication Abuse.This issue affects Handheld Scanners: from C1 Base(Ingenic x1000) before GK000432BAA, from D1 Base(Ingenic x1600) before HE000085BAA, from A1/B1 Base(IMX25) before BK000763BAA_BK000765BAA_CU000101BAA.
This vulnerability could allow a remote attacker within Bluetooth range of the scanner's base station has the capability to remotely execute system commands on the host connected to the base station without authentication. This issue has been assigned CVE-2026-4272 https://nvd.nist.gov/vuln/detail/CVE-2026-4272 and rated with a severity of High. Honeywell strongly recommends that users upgrade to the latest version identified to resolve the vulnerability.
Severity
8.1 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | Barcode Scanners |
Affected:
C1 Base(Ingenic x1000) , < GK000432BAA
(custom)
Affected: D1 Base(Ingenic x1600) , < HE000085BAA (custom) Affected: A1/B1 Base(IMX25) , < BK000763BAA_BK000765BAA_CU000101BAA (custom) |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-4272",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-06T14:00:57.144252Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T14:01:35.115Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Barcode Scanners",
"vendor": "Honeywell",
"versions": [
{
"lessThan": "GK000432BAA",
"status": "affected",
"version": "C1 Base(Ingenic x1000)",
"versionType": "custom"
},
{
"lessThan": "HE000085BAA",
"status": "affected",
"version": "D1 Base(Ingenic x1600)",
"versionType": "custom"
},
{
"lessThan": "BK000763BAA_BK000765BAA_CU000101BAA",
"status": "affected",
"version": "A1/B1 Base(IMX25)",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Kaspersky"
},
{
"lang": "en",
"type": "finder",
"value": "Haidar Kabibo"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Missing Authentication for Critical Function vulnerability in Honeywell Handheld Scanners allows Authentication Abuse.\u003cp\u003eThis issue affects Handheld Scanners: from C1 Base(Ingenic x1000) before GK000432BAA, from D1 Base(Ingenic x1600) before HE000085BAA, from A1/B1 Base(IMX25) before BK000763BAA_BK000765BAA_CU000101BAA.\u003c/p\u003eThis vulnerability could allow a remote attacker within Bluetooth range of the scanner\u0027s base station has the capability to remotely execute system commands on the host connected to the base station without authentication. This issue has been assigned\u0026nbsp;\u003ca href=\"https://nvd.nist.gov/vuln/detail/CVE-2026-4272\"\u003eCVE-2026-4272\u003c/a\u003e and rated with a severity of High. Honeywell strongly recommends that users upgrade to the latest version identified to resolve the vulnerability.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Missing Authentication for Critical Function vulnerability in Honeywell Handheld Scanners allows Authentication Abuse.This issue affects Handheld Scanners: from C1 Base(Ingenic x1000) before GK000432BAA, from D1 Base(Ingenic x1600) before HE000085BAA, from A1/B1 Base(IMX25) before BK000763BAA_BK000765BAA_CU000101BAA.\n\nThis vulnerability could allow a remote attacker within Bluetooth range of the scanner\u0027s base station has the capability to remotely execute system commands on the host connected to the base station without authentication. This issue has been assigned\u00a0 CVE-2026-4272 https://nvd.nist.gov/vuln/detail/CVE-2026-4272 and rated with a severity of High. Honeywell strongly recommends that users upgrade to the latest version identified to resolve the vulnerability."
}
],
"impacts": [
{
"capecId": "CAPEC-114",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-114 Authentication Abuse"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-05T22:00:27.141Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://https://nvd.nist.gov/vuln/detail/CVE-2026-4272"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "CVE-2026-4272 - Bluetooth Remote Execution of System Commands Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2026-4272",
"datePublished": "2026-04-05T22:00:27.141Z",
"dateReserved": "2026-03-16T14:45:35.186Z",
"dateUpdated": "2026-04-06T14:01:35.115Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3611 (GCVE-0-2026-3611)
Vulnerability from nvd – Published: 2026-03-12 20:06 – Updated: 2026-03-30 15:26
VLAI
Title
Honeywell IQ4x BMS Controller Missing authentication for critical function
Summary
The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 100) context, granting read/write privileges to any party able to reach the HTTP interface. Authentication controls are only enforced after a web user is created via U.htm, which dynamically enables the user module. Because this function is accessible prior to authentication, a remote user can create a new account with administrative read/write permissions enabling the user module and imposing authentication under attacker-controlled credentials. This action can effectively lock legitimate operators out of local and web-based configuration and administration.
Severity
10 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-306 - Missing authentication for critical function
Assigner
References
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | IQ4E |
Affected:
v3.50_3.44 , ≤ 4.36 (build 4.3.7.9)
(custom)
|
|
| Honeywell | IQ412 |
Affected:
v3.50_3.44 , ≤ 4.36 (build 4.3.7.9)
(custom)
|
|
| Honeywell | IQ422 |
Affected:
v3.50_3.44 , ≤ 4.36 (build 4.3.7.9)
(custom)
|
|
| Honeywell | IQ4NC |
Affected:
v3.50_3.44 , ≤ 4.36 (build 4.3.7.9)
(custom)
|
|
| Honeywell | IQ41x |
Affected:
v3.50_3.44 , ≤ 4.36 (build 4.3.7.9)
(custom)
|
|
| Honeywell | IQ3 |
Affected:
v3.50_3.44 , ≤ 4.36 (build 4.3.7.9)
(custom)
|
|
| Honeywell | IQECO |
Affected:
v3.50_3.44 , ≤ 4.36 (build 4.3.7.9)
(custom)
|
Date Public
2026-03-10 17:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3611",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-13T18:02:46.954644Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T18:03:02.081Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "IQ4E",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "4.36 (build 4.3.7.9)",
"status": "affected",
"version": "v3.50_3.44",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IQ412",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "4.36 (build 4.3.7.9)",
"status": "affected",
"version": "v3.50_3.44",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IQ422",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "4.36 (build 4.3.7.9)",
"status": "affected",
"version": "v3.50_3.44",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IQ4NC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "4.36 (build 4.3.7.9)",
"status": "affected",
"version": "v3.50_3.44",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IQ41x",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "4.36 (build 4.3.7.9)",
"status": "affected",
"version": "v3.50_3.44",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IQ3",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "4.36 (build 4.3.7.9)",
"status": "affected",
"version": "v3.50_3.44",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IQECO",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "4.36 (build 4.3.7.9)",
"status": "affected",
"version": "v3.50_3.44",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Gjoko Krstic of Zero Science reported this vulnerability to Honeywell."
}
],
"datePublic": "2026-03-10T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 100) context, granting read/write privileges to any party able to reach the HTTP interface. Authentication controls are only enforced after a web user is created via U.htm, which dynamically enables the user module. Because this function is accessible prior to authentication, a remote user can create a new account with administrative read/write permissions enabling the user module and imposing authentication under attacker-controlled credentials. This action can effectively lock legitimate operators out of local and web-based configuration and administration."
}
],
"value": "The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 100) context, granting read/write privileges to any party able to reach the HTTP interface. Authentication controls are only enforced after a web user is created via U.htm, which dynamically enables the user module. Because this function is accessible prior to authentication, a remote user can create a new account with administrative read/write permissions enabling the user module and imposing authentication under attacker-controlled credentials. This action can effectively lock legitimate operators out of local and web-based configuration and administration."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing authentication for critical function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-30T15:26:08.604Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-069-03"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-069-03.json"
},
{
"url": "https://www.honeywell.com/us/en/contact"
}
],
"source": {
"advisory": "ICSA-26-069-03",
"discovery": "EXTERNAL"
},
"title": "Honeywell IQ4x BMS Controller Missing authentication for critical function",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Honeywell is aware of the issue, but has not released a fix. For more \ninformation, contact Honeywell directly. \n[https://www.honeywell.com/us/en/contact](https://www.honeywell.com/us/en/contact)."
}
],
"value": "Honeywell is aware of the issue, but has not released a fix. For more \ninformation, contact Honeywell directly. \n[https://www.honeywell.com/us/en/contact](https://www.honeywell.com/us/en/contact)."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-3611",
"datePublished": "2026-03-12T20:06:05.753Z",
"dateReserved": "2026-03-05T18:12:38.425Z",
"dateUpdated": "2026-03-30T15:26:08.604Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-1670 (GCVE-0-2026-1670)
Vulnerability from nvd – Published: 2026-02-17 22:56 – Updated: 2026-02-18 20:45
VLAI
Title
Honeywell CCTV Products Missing Authentication for Critical Function
Summary
The affected products are vulnerable to an unauthenticated API endpoint exposure, which may allow an attacker to remotely change the "forgot password" recovery email address.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | I-HIB2PI-UL 2MP IP |
Affected:
6.1.22.1216
|
|
| Honeywell | SMB NDAA MVO-3 |
Affected:
WDR_2MP_32M_PTZ_v2.0
|
|
| Honeywell | PTZ WDR 2MP 32M |
Affected:
WDR_2MP_32M_PTZ_v2.0
|
|
| Honeywell | 25M IPC |
Affected:
WDR_2MP_32M_PTZ_v2.0
|
Date Public
2026-02-17 17:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-1670",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-18T20:45:37.144272Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-18T20:45:46.226Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "I-HIB2PI-UL 2MP IP",
"vendor": "Honeywell",
"versions": [
{
"status": "affected",
"version": "6.1.22.1216"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SMB NDAA MVO-3",
"vendor": "Honeywell",
"versions": [
{
"status": "affected",
"version": "WDR_2MP_32M_PTZ_v2.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PTZ WDR 2MP 32M",
"vendor": "Honeywell",
"versions": [
{
"status": "affected",
"version": "WDR_2MP_32M_PTZ_v2.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "25M IPC",
"vendor": "Honeywell",
"versions": [
{
"status": "affected",
"version": "WDR_2MP_32M_PTZ_v2.0"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Souvik Kandar reported this vulnerability to CISA."
}
],
"datePublic": "2026-02-17T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The affected products are vulnerable to an unauthenticated API endpoint exposure, which may allow an attacker to remotely change the \"forgot password\" recovery email address."
}
],
"value": "The affected products are vulnerable to an unauthenticated API endpoint exposure, which may allow an attacker to remotely change the \"forgot password\" recovery email address."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-17T22:56:00.586Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-048-04"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-048-04.json"
},
{
"url": "https://www.honeywell.com/us/en/contact/support"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Honeywell recommends users contact Honeywell at \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.honeywell.com/us/en/contact/support\"\u003ehttps://www.honeywell.com/us/en/contact/support\u003c/a\u003e for patch information.\u003cbr\u003e"
}
],
"value": "Honeywell recommends users contact Honeywell at https://www.honeywell.com/us/en/contact/support for patch information."
}
],
"source": {
"advisory": "ICSA-26-048-04",
"discovery": "EXTERNAL"
},
"title": "Honeywell CCTV Products Missing Authentication for Critical Function",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-1670",
"datePublished": "2026-02-17T22:56:00.586Z",
"dateReserved": "2026-01-30T00:35:22.440Z",
"dateUpdated": "2026-02-18T20:45:46.226Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-47868 (GCVE-0-2021-47868)
Vulnerability from nvd – Published: 2026-01-21 17:27 – Updated: 2026-03-05 01:29
VLAI
Title
WIN-PACK PRO 4.8 - 'WPCommandFileService' Unquoted Service Path
Summary
WIN-PACK PRO 4.8 contains an unquoted service path vulnerability in the WPCommandFileService that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\Program Files <x86>\WINPAKPRO\WPCommandFileService Service.exe to inject malicious code that would execute with LocalSystem permissions.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-428 - Unquoted Search Path or Element
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.exploit-db.com/exploits/49692 | exploit |
| https://www.security.honeywell.com/product-reposi… | product |
| https://www.vulncheck.com/advisories/win-pack-pro… | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | WIN-PACK PRO |
Affected:
4.8
|
Date Public
2021-03-16 00:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-47868",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-22T16:47:10.898897Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-22T16:52:36.282Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "WIN-PACK PRO",
"vendor": "Honeywell",
"versions": [
{
"status": "affected",
"version": "4.8"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:honeywell:win-pak:4.8:*:*:*:*:*:*:*",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Alan Mondragon"
}
],
"datePublic": "2021-03-16T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "WIN-PACK PRO 4.8 contains an unquoted service path vulnerability in the WPCommandFileService that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\\Program Files \u003cx86\u003e\\WINPAKPRO\\WPCommandFileService Service.exe to inject malicious code that would execute with LocalSystem permissions."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS"
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "Unquoted Search Path or Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-05T01:29:00.395Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "ExploitDB-49692",
"tags": [
"exploit"
],
"url": "https://www.exploit-db.com/exploits/49692"
},
{
"name": "Honeywell Product Webpage",
"tags": [
"product"
],
"url": "https://www.security.honeywell.com/product-repository/winpak"
},
{
"name": "VulnCheck Advisory: WIN-PACK PRO 4.8 - \u0027WPCommandFileService\u0027 Unquoted Service Path",
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/win-pack-pro-wpcommandfileservice-unquoted-service-path"
}
],
"title": "WIN-PACK PRO 4.8 - \u0027WPCommandFileService\u0027 Unquoted Service Path",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2021-47868",
"datePublished": "2026-01-21T17:27:45.785Z",
"dateReserved": "2026-01-18T12:35:05.171Z",
"dateUpdated": "2026-03-05T01:29:00.395Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-47866 (GCVE-0-2021-47866)
Vulnerability from nvd – Published: 2026-01-21 17:27 – Updated: 2026-03-05 01:28
VLAI
Title
WIN-PACK PRO 4.8 - 'GuardTourService' Unquoted Service Path
Summary
WIN-PACK PRO 4.8 contains an unquoted service path vulnerability in the GuardTourService that allows local users to potentially execute code with elevated system privileges. Attackers can exploit the unquoted path in C:\Program Files <x86>\WINPAKPRO\WP GuardTour Service.exe to inject malicious code that would execute during service startup.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-428 - Unquoted Search Path or Element
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.exploit-db.com/exploits/49690 | exploit |
| https://www.security.honeywell.com/product-reposi… | product |
| https://www.vulncheck.com/advisories/win-pack-pro… | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | WIN-PACK PRO |
Affected:
4.8
|
Date Public
2021-03-16 00:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-47866",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-22T16:47:15.941886Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-22T16:52:45.690Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "WIN-PACK PRO",
"vendor": "Honeywell",
"versions": [
{
"status": "affected",
"version": "4.8"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:honeywell:win-pak:4.8:*:*:*:*:*:*:*",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Alan Mondragon"
}
],
"datePublic": "2021-03-16T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "WIN-PACK PRO 4.8 contains an unquoted service path vulnerability in the GuardTourService that allows local users to potentially execute code with elevated system privileges. Attackers can exploit the unquoted path in C:\\Program Files \u003cx86\u003e\\WINPAKPRO\\WP GuardTour Service.exe to inject malicious code that would execute during service startup."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS"
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "Unquoted Search Path or Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-05T01:28:59.472Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "ExploitDB-49690",
"tags": [
"exploit"
],
"url": "https://www.exploit-db.com/exploits/49690"
},
{
"name": "Honeywell Product Webpage",
"tags": [
"product"
],
"url": "https://www.security.honeywell.com/product-repository/winpak"
},
{
"name": "VulnCheck Advisory: WIN-PACK PRO 4.8 - \u0027GuardTourService\u0027 Unquoted Service Path",
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/win-pack-pro-guardtourservice-unquoted-service-path"
}
],
"title": "WIN-PACK PRO 4.8 - \u0027GuardTourService\u0027 Unquoted Service Path",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2021-47866",
"datePublished": "2026-01-21T17:27:44.672Z",
"dateReserved": "2026-01-18T12:35:05.170Z",
"dateUpdated": "2026-03-05T01:28:59.472Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-12351 (GCVE-0-2025-12351)
Vulnerability from nvd – Published: 2025-10-27 15:03 – Updated: 2025-10-27 16:04
VLAI
Title
Inadequate access control measure allows unauthorized users to access restricted administrative functions
Summary
Honeywell S35 Series Cameras contains an authorization bypass Vulnerability through User controller key. An attacker could potentially exploit this vulnerability, leading to Privilege Escalation to admin privileged functionalities . Honeywell also recommends updating to the most recent version of this product, service or offering (S35 Pinhole/Kit Camera to version 2025.08.28, S35 AI Fisheye & Dual Sensor/Micro Dome/Full Color Eyeball & Bullet Camera to version 2025.08.22, S35 Thermal Camera to version 2025.08.26).
Severity
6.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.honeywell.com/us/en/product-security | vendor-advisory |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | S35 3M/5M/8M/Pinhole/Kit Camera |
Affected:
2022.02.28 , < 2025.08.28
(date)
|
|
| Honeywell | S35 AI Fisheye&Dual Sensor/Micro Dome/Full Color Eyeball&Bullet Camera |
Affected:
2024.08.10 , < 2025.08.22
(date)
|
|
| Honeywell | S35 Thermal Camera |
Affected:
2024.10.21 , < 2025.08.26
(date)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-12351",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-27T15:14:48.505227Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-27T16:04:11.466Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Linux"
],
"product": "S35 3M/5M/8M/Pinhole/Kit Camera",
"vendor": "Honeywell",
"versions": [
{
"lessThan": "2025.08.28",
"status": "affected",
"version": "2022.02.28",
"versionType": "date"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Linux"
],
"product": "S35 AI Fisheye\u0026Dual Sensor/Micro Dome/Full Color Eyeball\u0026Bullet Camera",
"vendor": "Honeywell",
"versions": [
{
"lessThan": "2025.08.22",
"status": "affected",
"version": "2024.08.10",
"versionType": "date"
}
]
},
{
"defaultStatus": "unaffected",
"product": "S35 Thermal Camera",
"vendor": "Honeywell",
"versions": [
{
"lessThan": "2025.08.26",
"status": "affected",
"version": "2024.10.21",
"versionType": "date"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Honeywell S35 Series Cameras contains an authorization bypass Vulnerability through User controller key. An attacker could potentially exploit this vulnerability, leading to Privilege Escalation to admin privileged functionalities . Honeywell also recommends updating to the most recent version of this product, service or offering (S35 Pinhole/Kit Camera to version 2025.08.28, S35 AI Fisheye \u0026amp; Dual Sensor/Micro Dome/Full Color Eyeball \u0026amp; Bullet Camera to version 2025.08.22, S35 Thermal Camera to version 2025.08.26).\u003cp\u003e\u003c/p\u003e"
}
],
"value": "Honeywell S35 Series Cameras contains an authorization bypass Vulnerability through User controller key. An attacker could potentially exploit this vulnerability, leading to Privilege Escalation to admin privileged functionalities . Honeywell also recommends updating to the most recent version of this product, service or offering (S35 Pinhole/Kit Camera to version 2025.08.28, S35 AI Fisheye \u0026 Dual Sensor/Micro Dome/Full Color Eyeball \u0026 Bullet Camera to version 2025.08.22, S35 Thermal Camera to version 2025.08.26)."
}
],
"impacts": [
{
"capecId": "CAPEC-22",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-22 Exploiting Trust in Client"
}
]
},
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233 Privilege Escalation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-639",
"description": "CWE-639 Authorization Bypass Through User-Controlled Key",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668 Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-27T15:03:57.602Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.honeywell.com/us/en/product-security"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Inadequate access control measure allows unauthorized users to access restricted administrative functions",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2025-12351",
"datePublished": "2025-10-27T15:03:57.602Z",
"dateReserved": "2025-10-27T14:59:57.822Z",
"dateUpdated": "2025-10-27T16:04:11.466Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3947 (GCVE-0-2025-3947)
Vulnerability from nvd – Published: 2025-07-10 20:19 – Updated: 2025-08-04 19:46
VLAI
Title
Integer underflow during processing of short network packets in CDA FTEB responder
Summary
The Honeywell Experion PKS contains an Integer Underflow
vulnerability
in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to
Input Data Manipulation, which could result in improper integer data value checking during subtraction leading to a denial of service.
Honeywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1.
The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.
Severity
8.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-191 - Integer Underflow (Wrap or Wraparound)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://process.honeywell.com/ |
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | C300 PCNT02 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300 PCNT05 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM4 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM8 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | UOC |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | CN100 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | HCA |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300PM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C200E |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3947",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-10T20:34:52.670505Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-10T20:35:01.787Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT02",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT05",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM4",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM8",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "UOC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "CN100",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "HCA",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300PM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C200E",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Demid Uzenkov and Kirill Kutaev (Positive Technologies)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Honeywell Experion PKS contains an Integer Underflow \n\nvulnerability \n\nin the component Control\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eData Access (CDA). An attacker could potentially exploit this vulnerability, leading to \n\nInput Data Manipulation, which could result in improper\u0026nbsp;integer data value checking during subtraction leading to a denial of service.\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cbr\u003e\u003c/span\u003e\u003c/span\u003e\n\nHoneywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1.\u003cbr\u003e\u003cbr\u003eThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.\n\n\u003cbr\u003e"
}
],
"value": "The Honeywell Experion PKS contains an Integer Underflow \n\nvulnerability \n\nin the component Control\u00a0Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to \n\nInput Data Manipulation, which could result in improper\u00a0integer data value checking during subtraction leading to a denial of service.\n\n\n\nHoneywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1.\n\nThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3."
}
],
"impacts": [
{
"capecId": "CAPEC-153",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-153 Input Data Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-191",
"description": "CWE-191 Integer Underflow (Wrap or Wraparound)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T19:46:31.982Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Integer underflow during processing of short network packets in CDA FTEB responder",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2025-3947",
"datePublished": "2025-07-10T20:19:13.991Z",
"dateReserved": "2025-04-25T15:21:22.614Z",
"dateUpdated": "2025-08-04T19:46:31.982Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3946 (GCVE-0-2025-3946)
Vulnerability from nvd – Published: 2025-07-10 20:16 – Updated: 2025-08-04 19:46
VLAI
Title
Incorrect response generation during FTEB protocol processing
Summary
The Honeywell Experion PKS
and OneWireless WDM
contains a Deployment of Wrong Handler
vulnerability
in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to
Input Data Manipulation,
which could result in incorrect handling of packets leading to remote code execution.
Honeywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.
The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.
Severity
8.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-430 - Deployment of Wrong Handler
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://process.honeywell.com/ |
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | C300 PCNT02 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300 PCNT05 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM4 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM8 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | UOC |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | CN100 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | HCA |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300PM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C200E |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | Wireless Device Manager |
Affected:
322.1 , ≤ 322.4
(semver)
Affected: 330.1 , ≤ 330.3 (semver) |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3946",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-10T20:35:19.798404Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-10T20:35:28.409Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT02",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT05",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM4",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM8",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "UOC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "CN100",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "HCA",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300PM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C200E",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"OneWireless"
],
"product": "Wireless Device Manager",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "322.4",
"status": "affected",
"version": "322.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "330.3",
"status": "affected",
"version": "330.1",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Demid Uzenkov and Kirill Kutaev (Positive Technologies)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Honeywell Experion PKS \n\nand OneWireless WDM\n\ncontains a Deployment of Wrong Handler\n\n \n\nvulnerability \n\nin the component Control\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eData Access (CDA). An attacker could potentially exploit this vulnerability, leading to \n\nInput Data Manipulation, \n\n which could result in incorrect handling of packets leading to remote code execution.\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cbr\u003e\u003cbr\u003e\n\nHoneywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.\u003cbr\u003e\u003cbr\u003eThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.\u003c/span\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.\n\n\u003cbr\u003e\u003c/span\u003e"
}
],
"value": "The Honeywell Experion PKS \n\nand OneWireless WDM\n\ncontains a Deployment of Wrong Handler\n\n \n\nvulnerability \n\nin the component Control\u00a0Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to \n\nInput Data Manipulation, \n\n which could result in incorrect handling of packets leading to remote code execution.\n\n\n\nHoneywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.\n\nThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.\u00a0The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3."
}
],
"impacts": [
{
"capecId": "CAPEC-153",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-153 Input Data Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-430",
"description": "CWE-430 Deployment of Wrong Handler",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T19:46:15.112Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Incorrect response generation during FTEB protocol processing",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2025-3946",
"datePublished": "2025-07-10T20:16:54.743Z",
"dateReserved": "2025-04-25T15:21:21.740Z",
"dateUpdated": "2025-08-04T19:46:15.112Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2523 (GCVE-0-2025-2523)
Vulnerability from nvd – Published: 2025-07-10 20:15 – Updated: 2025-08-04 19:45
VLAI
Title
Lack of buffer clearing before reuse may result in incorrect system behavior.
Summary
The Honeywell Experion PKS
and OneWireless WDM
contains an Integer Underflow
vulnerability
in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in a failure during subtraction allowing remote code execution.
Honeywell recommends updating to the most recent version of
Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.
The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.
Severity
9.4 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-191 - Integer Underflow (Wrap or Wraparound)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://process.honeywell.com/ |
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | C300 PCNT02 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300 PCNT05 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM4 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM8 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | UOC |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | CN100 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | HCA |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300PM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C200E |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | Wireless Device Manager |
Affected:
322.1 , ≤ 322.4
(semver)
Affected: 330.1 , ≤ 330.3 (semver) |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2523",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-10T20:35:45.591675Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-10T20:35:53.232Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT02",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT05",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM4",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM8",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "UOC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "CN100",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "HCA",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300PM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C200E",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"OneWireless"
],
"product": "Wireless Device Manager",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "322.4",
"status": "affected",
"version": "322.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "330.3",
"status": "affected",
"version": "330.1",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Demid Uzenkov and Kirill Kutaev (Positive Technologies)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Honeywell Experion PKS \n\n and OneWireless WDM \n\ncontains an Integer Underflow \n\nvulnerability \n\nin the component Control\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eData Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in a failure\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;during subtraction allowing remote code execution.\u003c/span\u003e\u003c/span\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cbr\u003e\u003cbr\u003eHoneywell recommends updating to the most recent version of \n\nHoneywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.\u003cbr\u003e\u003c/span\u003e\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\nThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.\n\n\u003c/span\u003e\u003cbr\u003e"
}
],
"value": "The Honeywell Experion PKS \n\n and OneWireless WDM \n\ncontains an Integer Underflow \n\nvulnerability \n\nin the component Control\u00a0Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in a failure\u00a0during subtraction allowing remote code execution.\n\n\n\nHoneywell recommends updating to the most recent version of \n\nHoneywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.\n\n\n\nThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3."
}
],
"impacts": [
{
"capecId": "CAPEC-216",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-216 Communication Channel Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-191",
"description": "CWE-191 Integer Underflow (Wrap or Wraparound)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T19:45:51.105Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Lack of buffer clearing before reuse may result in incorrect system behavior.",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2025-2523",
"datePublished": "2025-07-10T20:15:32.600Z",
"dateReserved": "2025-03-19T13:57:31.419Z",
"dateUpdated": "2025-08-04T19:45:51.105Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2522 (GCVE-0-2025-2522)
Vulnerability from nvd – Published: 2025-07-10 20:11 – Updated: 2025-08-04 19:45
VLAI
Title
Lack of buffer clearing before reuse may result in incorrect system behavior.
Summary
The Honeywell Experion PKS and OneWireless WDM
contains Sensitive Information in Resource vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in buffer reuse which may cause incorrect system behavior.
Honeywell also recommends updating to the most recent version of
Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.
The affected Experion PKS products are
C300, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are 520.1 before
520.2 TCU9 HF1 and 530 before 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-226 - Sensitive Information in Resource Not Removed Before Reuse
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://process.honeywell.com/ |
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | C300 PCNT02 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300 PCNT05 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM4 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM8 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | UOC |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | CN100 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | HCA |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300PM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C200E |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | Wireless Device Manager |
Affected:
322.1 , ≤ 322.4
(semver)
Affected: 330.1 , ≤ 330.3 (semver) |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2522",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-10T20:34:00.516806Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-10T20:34:08.789Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT02",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT05",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM4",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM8",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "UOC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "CN100",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "HCA",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300PM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C200E",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"OneWireless"
],
"product": "Wireless Device Manager",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "322.4",
"status": "affected",
"version": "322.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "330.3",
"status": "affected",
"version": "330.1",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Demid Uzenkov and Kirill Kutaev (Positive Technologies)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Honeywell Experion PKS\u0026nbsp;and OneWireless WDM \n\n contains Sensitive Information in Resource vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in buffer reuse which may cause incorrect system behavior.\n\n\u003cp\u003eHoneywell also recommends updating to the most recent version of \n\nHoneywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.\u0026nbsp;\u003c/p\u003e\u003cp\u003eThe affected Experion PKS products are \n\n\n\nC300, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are 520.1 before \n\n520.2 TCU9 HF1 and 530 before 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.\u003c/p\u003e"
}
],
"value": "The Honeywell Experion PKS\u00a0and OneWireless WDM \n\n contains Sensitive Information in Resource vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in buffer reuse which may cause incorrect system behavior.\n\nHoneywell also recommends updating to the most recent version of \n\nHoneywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.\u00a0\n\nThe affected Experion PKS products are \n\n\n\nC300, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are 520.1 before \n\n520.2 TCU9 HF1 and 530 before 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3."
}
],
"impacts": [
{
"capecId": "CAPEC-216",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-216 Communication Channel Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-226",
"description": "CWE-226 Sensitive Information in Resource Not Removed Before Reuse",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T19:45:13.439Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Lack of buffer clearing before reuse may result in incorrect system behavior.",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2025-2522",
"datePublished": "2025-07-10T20:11:43.603Z",
"dateReserved": "2025-03-19T13:57:30.424Z",
"dateUpdated": "2025-08-04T19:45:13.439Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2521 (GCVE-0-2025-2521)
Vulnerability from nvd – Published: 2025-07-10 20:08 – Updated: 2025-08-04 19:44
VLAI
Title
Lack of indexes’ validation against buffer borders leads to remote code execution.
Summary
The Honeywell Experion PKS and OneWireless WDM contains a Memory Buffer vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to an Overread Buffers, which could result in improper index validation against buffer borders leading to remote code execution.
Honeywell recommends updating to the most recent version of Honeywell Experion PKS:
520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.
The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.
Severity
8.6 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://process.honeywell.com/ |
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | C300 PCNT02 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300 PCNT05 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM4 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM8 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | UOC |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | CN100 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | HCA |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300PM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C200E |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | Wireless Device Manager |
Affected:
322.1 , ≤ 322.4
(semver)
Affected: 330.1 , ≤ 330.3 (semver) |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2521",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-10T20:33:41.946048Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-10T20:33:49.166Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT02",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT05",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM4",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM8",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "UOC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "CN100",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "HCA",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300PM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C200E",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"OneWireless"
],
"product": "Wireless Device Manager",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "322.4",
"status": "affected",
"version": "322.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "330.3",
"status": "affected",
"version": "330.1",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Demid Uzenkov and Kirill Kutaev (Positive Technologies)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThe Honeywell Experion PKS and OneWireless WDM contains a Memory Buffer vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to an Overread Buffers, which could result in improper index validation against buffer borders leading to remote code execution.\u003c/p\u003e\u003cp\u003eHoneywell recommends updating to the most recent version of Honeywell Experion PKS:\n\n520.2 TCU9 HF1 and\u0026nbsp;530.1 TCU3 HF1 and OneWireless:\u0026nbsp;322.5 and 331.1.\u003c/p\u003e\u003cp\u003e\u003cbr\u003eThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.\u003c/p\u003e"
}
],
"value": "The Honeywell Experion PKS and OneWireless WDM contains a Memory Buffer vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to an Overread Buffers, which could result in improper index validation against buffer borders leading to remote code execution.\n\nHoneywell recommends updating to the most recent version of Honeywell Experion PKS:\n\n520.2 TCU9 HF1 and\u00a0530.1 TCU3 HF1 and OneWireless:\u00a0322.5 and 331.1.\n\n\nThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3."
}
],
"impacts": [
{
"capecId": "CAPEC-540",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-540 Overread Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T19:44:27.744Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Lack of indexes\u2019 validation against buffer borders leads to remote code execution.",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2025-2521",
"datePublished": "2025-07-10T20:08:04.077Z",
"dateReserved": "2025-03-19T13:57:29.165Z",
"dateUpdated": "2025-08-04T19:44:27.744Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2520 (GCVE-0-2025-2520)
Vulnerability from nvd – Published: 2025-07-10 19:54 – Updated: 2025-08-04 19:44
VLAI
Title
Dereferencing of an uninitialized pointer leads to denial of service.
Summary
The Honeywell Experion PKS contains an Uninitialized Variable in the common Epic Platform Analyzer (EPA) communications. An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which results in a dereferencing of an uninitialized pointer leading to a denial of service.
Honeywell recommends updating to the most recent version of
Honeywell Experion PKS: 520.2 TCU9 HF1and 530.1 TCU3 HF1. The affected Experion PKS products are
C300 PCNT02, EHB, EHPM, ELMM, Classic ENIM, ETN, FIM4, FIM8, PGM, and RFIM. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-457 - Use of Uninitialized Variable
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://process.honeywell.com/ |
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | C300 PCNT02 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | EHB |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | EHPM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | ELMM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | Classic ENIM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | ETN |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM4 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM8 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | PGM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | RFIM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2520",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-10T20:33:19.670618Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-10T20:33:30.482Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT02",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "EHB",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "EHPM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "ELMM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "Classic ENIM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "ETN",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM4",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM8",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "PGM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "RFIM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Demid Uzenkov and Kirill Kutaev (Positive Technologies)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe Honeywell Experion PKS contains an \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUninitialized Variable i\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003en the common Epic Platform Analyzer (EPA) communications\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e. An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which results in a d\u003c/span\u003eereferencing of an uninitialized pointer leading to a denial of service.\u003cbr\u003e\u003cbr\u003e\n\nHoneywell recommends updating to the most recent version of \n\nHoneywell Experion PKS: 520.2 TCU9 HF1and\u0026nbsp;530.1 TCU3 HF1.\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe affected Experion PKS products are \n\nC300 PCNT02, EHB, EHPM, ELMM, Classic ENIM, ETN, FIM4, FIM8, PGM, and RFIM. The Experion PKS versions affected are\u0026nbsp;from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.\u003c/span\u003e\u003cbr\u003e"
}
],
"value": "The Honeywell Experion PKS contains an Uninitialized Variable in the common Epic Platform Analyzer (EPA) communications. An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which results in a dereferencing of an uninitialized pointer leading to a denial of service.\n\n\n\nHoneywell recommends updating to the most recent version of \n\nHoneywell Experion PKS: 520.2 TCU9 HF1and\u00a0530.1 TCU3 HF1.\u00a0The affected Experion PKS products are \n\nC300 PCNT02, EHB, EHPM, ELMM, Classic ENIM, ETN, FIM4, FIM8, PGM, and RFIM. The Experion PKS versions affected are\u00a0from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3."
}
],
"impacts": [
{
"capecId": "CAPEC-216",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-216 Communication Channel Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-457",
"description": "CWE-457 Use of Uninitialized Variable",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T19:44:48.506Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Dereferencing of an uninitialized pointer leads to denial of service.",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2025-2520",
"datePublished": "2025-07-10T19:54:35.250Z",
"dateReserved": "2025-03-19T13:57:27.868Z",
"dateUpdated": "2025-08-04T19:44:48.506Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2605 (GCVE-0-2025-2605)
Vulnerability from nvd – Published: 2025-05-02 12:39 – Updated: 2025-05-17 06:03
VLAI
Title
Authenticated command injection
Summary
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product.
Severity
9.9 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.honeywell.com/us/en/product-security#… | vendor-advisory |
| http://seclists.org/fulldisclosure/2025/May/19 |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2605",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-02T13:32:21.228869Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-02T13:32:33.807Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-05-17T06:03:36.347Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/May/19"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "MB-Secure",
"vendor": "Honeywell",
"versions": [
{
"lessThan": "V12.53",
"status": "affected",
"version": "V11.04",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product."
}
],
"value": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product."
}
],
"impacts": [
{
"capecId": "CAPEC-122",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-122 Privilege Abuse"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-02T12:39:39.979Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.honeywell.com/us/en/product-security#security-notices"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Authenticated command injection",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2025-2605",
"datePublished": "2025-05-02T12:39:39.979Z",
"dateReserved": "2025-03-21T13:18:29.509Z",
"dateUpdated": "2025-05-17T06:03:36.347Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-5878 (GCVE-0-2023-5878)
Vulnerability from nvd – Published: 2025-02-06 14:10 – Updated: 2025-02-18 18:13
VLAI
Title
OneWireless command injection possible when updating firmware
Summary
Honeywell OneWireless
Wireless Device Manager (WDM) for the following versions R310.x, R320.x, R321.x, R322.1, R322.2, R323.x, R330.1 contains a command injection vulnerability. An attacker who is authenticated could use the firmware update process to potentially exploit the vulnerability, leading to a command injection. Honeywell recommends updating to
R322.3, R330.2 or the most recent version of this product2.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://process.honeywell.com/ |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | OneWireless Network Wireless Device Manager |
Affected:
310.1 , ≤ 322.2
(semver)
Affected: 323.1 , ≤ 330.1 (semver) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5878",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-06T14:26:15.468750Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-18T18:13:44.990Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Linux"
],
"product": "OneWireless Network Wireless Device Manager",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "322.2",
"status": "affected",
"version": "310.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "330.1",
"status": "affected",
"version": "323.1",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eHoneywell OneWireless \n\nWireless Device Manager (WDM)\u0026nbsp;for the following versions R310.x, R320.x, R321.x, R322.1, R322.2, R323.x, R330.1 contains a command injection vulnerability. An attacker who is authenticated could use the firmware update process to potentially exploit the vulnerability, leading to a command injection. Honeywell recommends updating to \n\n R322.3, R330.2 or the most recent version of this product2.\n\n\u003c/span\u003e\u003cbr\u003e"
}
],
"value": "Honeywell OneWireless \n\nWireless Device Manager (WDM)\u00a0for the following versions R310.x, R320.x, R321.x, R322.1, R322.2, R323.x, R330.1 contains a command injection vulnerability. An attacker who is authenticated could use the firmware update process to potentially exploit the vulnerability, leading to a command injection. Honeywell recommends updating to \n\n R322.3, R330.2 or the most recent version of this product2."
}
],
"impacts": [
{
"capecId": "CAPEC-248",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-248 Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-06T14:10:30.295Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "OneWireless command injection possible when updating firmware",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2023-5878",
"datePublished": "2025-02-06T14:10:30.295Z",
"dateReserved": "2023-10-31T13:16:00.514Z",
"dateUpdated": "2025-02-18T18:13:44.990Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-6620 (GCVE-0-2024-6620)
Vulnerability from nvd – Published: 2024-07-29 20:14 – Updated: 2024-08-01 21:41
VLAI
Summary
Honeywell PC42t, PC42tp, and PC42d Printers, T10.19.020016 to T10.20.060398, contain a cross-site scripting vulnerability. A(n) attacker could potentially inject malicious code which may lead to information disclosure, session theft, or client-side request forgery. Honeywell recommends updating to the most recent version of this firmware, PC42 Printer Firmware Version 20.6 T10.20.060398.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://sps.honeywell.com/us/en/support/productiv… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | PC42t, PC42tp, and PC42d (Common Firmware) |
Affected:
T10.19.020016 , < T10.20.060398
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-6620",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-30T14:17:52.818483Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-30T14:17:59.561Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:41:03.974Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://sps.honeywell.com/us/en/support/productivity/cyber-security-notifications"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PC42t, PC42tp, and PC42d (Common Firmware)",
"vendor": "Honeywell",
"versions": [
{
"changes": [
{
"at": "T10.20.060398",
"status": "unaffected"
}
],
"lessThan": "T10.20.060398",
"status": "affected",
"version": "T10.19.020016",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Honeywell PC42t, PC42tp, and PC42d Printers, T10.19.020016 to T10.20.060398, contain a cross-site scripting vulnerability. A(n) attacker could potentially inject malicious code which may lead to information disclosure, session theft, or client-side request forgery. Honeywell recommends updating to the most recent version of this firmware, PC42 Printer Firmware Version 20.6 T10.20.060398."
}
],
"value": "Honeywell PC42t, PC42tp, and PC42d Printers, T10.19.020016 to T10.20.060398, contain a cross-site scripting vulnerability. A(n) attacker could potentially inject malicious code which may lead to information disclosure, session theft, or client-side request forgery. Honeywell recommends updating to the most recent version of this firmware, PC42 Printer Firmware Version 20.6 T10.20.060398."
}
],
"impacts": [
{
"capecId": "CAPEC-63",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-63 Cross-Site Scripting (XSS)"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-602",
"description": "CWE-602",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-29T20:14:27.666Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://sps.honeywell.com/us/en/support/productivity/cyber-security-notifications"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2024-6620",
"datePublished": "2024-07-29T20:14:27.666Z",
"dateReserved": "2024-07-09T15:50:58.050Z",
"dateUpdated": "2024-08-01T21:41:03.974Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2026-4272 (GCVE-0-2026-4272)
Vulnerability from cvelistv5 – Published: 2026-04-05 22:00 – Updated: 2026-04-06 14:01
VLAI
Title
CVE-2026-4272 - Bluetooth Remote Execution of System Commands Vulnerability
Summary
Missing Authentication for Critical Function vulnerability in Honeywell Handheld Scanners allows Authentication Abuse.This issue affects Handheld Scanners: from C1 Base(Ingenic x1000) before GK000432BAA, from D1 Base(Ingenic x1600) before HE000085BAA, from A1/B1 Base(IMX25) before BK000763BAA_BK000765BAA_CU000101BAA.
This vulnerability could allow a remote attacker within Bluetooth range of the scanner's base station has the capability to remotely execute system commands on the host connected to the base station without authentication. This issue has been assigned CVE-2026-4272 https://nvd.nist.gov/vuln/detail/CVE-2026-4272 and rated with a severity of High. Honeywell strongly recommends that users upgrade to the latest version identified to resolve the vulnerability.
Severity
8.1 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | Barcode Scanners |
Affected:
C1 Base(Ingenic x1000) , < GK000432BAA
(custom)
Affected: D1 Base(Ingenic x1600) , < HE000085BAA (custom) Affected: A1/B1 Base(IMX25) , < BK000763BAA_BK000765BAA_CU000101BAA (custom) |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-4272",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-06T14:00:57.144252Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T14:01:35.115Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Barcode Scanners",
"vendor": "Honeywell",
"versions": [
{
"lessThan": "GK000432BAA",
"status": "affected",
"version": "C1 Base(Ingenic x1000)",
"versionType": "custom"
},
{
"lessThan": "HE000085BAA",
"status": "affected",
"version": "D1 Base(Ingenic x1600)",
"versionType": "custom"
},
{
"lessThan": "BK000763BAA_BK000765BAA_CU000101BAA",
"status": "affected",
"version": "A1/B1 Base(IMX25)",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Kaspersky"
},
{
"lang": "en",
"type": "finder",
"value": "Haidar Kabibo"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Missing Authentication for Critical Function vulnerability in Honeywell Handheld Scanners allows Authentication Abuse.\u003cp\u003eThis issue affects Handheld Scanners: from C1 Base(Ingenic x1000) before GK000432BAA, from D1 Base(Ingenic x1600) before HE000085BAA, from A1/B1 Base(IMX25) before BK000763BAA_BK000765BAA_CU000101BAA.\u003c/p\u003eThis vulnerability could allow a remote attacker within Bluetooth range of the scanner\u0027s base station has the capability to remotely execute system commands on the host connected to the base station without authentication. This issue has been assigned\u0026nbsp;\u003ca href=\"https://nvd.nist.gov/vuln/detail/CVE-2026-4272\"\u003eCVE-2026-4272\u003c/a\u003e and rated with a severity of High. Honeywell strongly recommends that users upgrade to the latest version identified to resolve the vulnerability.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Missing Authentication for Critical Function vulnerability in Honeywell Handheld Scanners allows Authentication Abuse.This issue affects Handheld Scanners: from C1 Base(Ingenic x1000) before GK000432BAA, from D1 Base(Ingenic x1600) before HE000085BAA, from A1/B1 Base(IMX25) before BK000763BAA_BK000765BAA_CU000101BAA.\n\nThis vulnerability could allow a remote attacker within Bluetooth range of the scanner\u0027s base station has the capability to remotely execute system commands on the host connected to the base station without authentication. This issue has been assigned\u00a0 CVE-2026-4272 https://nvd.nist.gov/vuln/detail/CVE-2026-4272 and rated with a severity of High. Honeywell strongly recommends that users upgrade to the latest version identified to resolve the vulnerability."
}
],
"impacts": [
{
"capecId": "CAPEC-114",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-114 Authentication Abuse"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-05T22:00:27.141Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://https://nvd.nist.gov/vuln/detail/CVE-2026-4272"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "CVE-2026-4272 - Bluetooth Remote Execution of System Commands Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2026-4272",
"datePublished": "2026-04-05T22:00:27.141Z",
"dateReserved": "2026-03-16T14:45:35.186Z",
"dateUpdated": "2026-04-06T14:01:35.115Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3611 (GCVE-0-2026-3611)
Vulnerability from cvelistv5 – Published: 2026-03-12 20:06 – Updated: 2026-03-30 15:26
VLAI
Title
Honeywell IQ4x BMS Controller Missing authentication for critical function
Summary
The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 100) context, granting read/write privileges to any party able to reach the HTTP interface. Authentication controls are only enforced after a web user is created via U.htm, which dynamically enables the user module. Because this function is accessible prior to authentication, a remote user can create a new account with administrative read/write permissions enabling the user module and imposing authentication under attacker-controlled credentials. This action can effectively lock legitimate operators out of local and web-based configuration and administration.
Severity
10 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-306 - Missing authentication for critical function
Assigner
References
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | IQ4E |
Affected:
v3.50_3.44 , ≤ 4.36 (build 4.3.7.9)
(custom)
|
|
| Honeywell | IQ412 |
Affected:
v3.50_3.44 , ≤ 4.36 (build 4.3.7.9)
(custom)
|
|
| Honeywell | IQ422 |
Affected:
v3.50_3.44 , ≤ 4.36 (build 4.3.7.9)
(custom)
|
|
| Honeywell | IQ4NC |
Affected:
v3.50_3.44 , ≤ 4.36 (build 4.3.7.9)
(custom)
|
|
| Honeywell | IQ41x |
Affected:
v3.50_3.44 , ≤ 4.36 (build 4.3.7.9)
(custom)
|
|
| Honeywell | IQ3 |
Affected:
v3.50_3.44 , ≤ 4.36 (build 4.3.7.9)
(custom)
|
|
| Honeywell | IQECO |
Affected:
v3.50_3.44 , ≤ 4.36 (build 4.3.7.9)
(custom)
|
Date Public
2026-03-10 17:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3611",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-13T18:02:46.954644Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T18:03:02.081Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "IQ4E",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "4.36 (build 4.3.7.9)",
"status": "affected",
"version": "v3.50_3.44",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IQ412",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "4.36 (build 4.3.7.9)",
"status": "affected",
"version": "v3.50_3.44",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IQ422",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "4.36 (build 4.3.7.9)",
"status": "affected",
"version": "v3.50_3.44",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IQ4NC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "4.36 (build 4.3.7.9)",
"status": "affected",
"version": "v3.50_3.44",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IQ41x",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "4.36 (build 4.3.7.9)",
"status": "affected",
"version": "v3.50_3.44",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IQ3",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "4.36 (build 4.3.7.9)",
"status": "affected",
"version": "v3.50_3.44",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IQECO",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "4.36 (build 4.3.7.9)",
"status": "affected",
"version": "v3.50_3.44",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Gjoko Krstic of Zero Science reported this vulnerability to Honeywell."
}
],
"datePublic": "2026-03-10T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 100) context, granting read/write privileges to any party able to reach the HTTP interface. Authentication controls are only enforced after a web user is created via U.htm, which dynamically enables the user module. Because this function is accessible prior to authentication, a remote user can create a new account with administrative read/write permissions enabling the user module and imposing authentication under attacker-controlled credentials. This action can effectively lock legitimate operators out of local and web-based configuration and administration."
}
],
"value": "The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 100) context, granting read/write privileges to any party able to reach the HTTP interface. Authentication controls are only enforced after a web user is created via U.htm, which dynamically enables the user module. Because this function is accessible prior to authentication, a remote user can create a new account with administrative read/write permissions enabling the user module and imposing authentication under attacker-controlled credentials. This action can effectively lock legitimate operators out of local and web-based configuration and administration."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing authentication for critical function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-30T15:26:08.604Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-069-03"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-069-03.json"
},
{
"url": "https://www.honeywell.com/us/en/contact"
}
],
"source": {
"advisory": "ICSA-26-069-03",
"discovery": "EXTERNAL"
},
"title": "Honeywell IQ4x BMS Controller Missing authentication for critical function",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Honeywell is aware of the issue, but has not released a fix. For more \ninformation, contact Honeywell directly. \n[https://www.honeywell.com/us/en/contact](https://www.honeywell.com/us/en/contact)."
}
],
"value": "Honeywell is aware of the issue, but has not released a fix. For more \ninformation, contact Honeywell directly. \n[https://www.honeywell.com/us/en/contact](https://www.honeywell.com/us/en/contact)."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-3611",
"datePublished": "2026-03-12T20:06:05.753Z",
"dateReserved": "2026-03-05T18:12:38.425Z",
"dateUpdated": "2026-03-30T15:26:08.604Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-1670 (GCVE-0-2026-1670)
Vulnerability from cvelistv5 – Published: 2026-02-17 22:56 – Updated: 2026-02-18 20:45
VLAI
Title
Honeywell CCTV Products Missing Authentication for Critical Function
Summary
The affected products are vulnerable to an unauthenticated API endpoint exposure, which may allow an attacker to remotely change the "forgot password" recovery email address.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | I-HIB2PI-UL 2MP IP |
Affected:
6.1.22.1216
|
|
| Honeywell | SMB NDAA MVO-3 |
Affected:
WDR_2MP_32M_PTZ_v2.0
|
|
| Honeywell | PTZ WDR 2MP 32M |
Affected:
WDR_2MP_32M_PTZ_v2.0
|
|
| Honeywell | 25M IPC |
Affected:
WDR_2MP_32M_PTZ_v2.0
|
Date Public
2026-02-17 17:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-1670",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-18T20:45:37.144272Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-18T20:45:46.226Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "I-HIB2PI-UL 2MP IP",
"vendor": "Honeywell",
"versions": [
{
"status": "affected",
"version": "6.1.22.1216"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SMB NDAA MVO-3",
"vendor": "Honeywell",
"versions": [
{
"status": "affected",
"version": "WDR_2MP_32M_PTZ_v2.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PTZ WDR 2MP 32M",
"vendor": "Honeywell",
"versions": [
{
"status": "affected",
"version": "WDR_2MP_32M_PTZ_v2.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "25M IPC",
"vendor": "Honeywell",
"versions": [
{
"status": "affected",
"version": "WDR_2MP_32M_PTZ_v2.0"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Souvik Kandar reported this vulnerability to CISA."
}
],
"datePublic": "2026-02-17T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The affected products are vulnerable to an unauthenticated API endpoint exposure, which may allow an attacker to remotely change the \"forgot password\" recovery email address."
}
],
"value": "The affected products are vulnerable to an unauthenticated API endpoint exposure, which may allow an attacker to remotely change the \"forgot password\" recovery email address."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-17T22:56:00.586Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-048-04"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-048-04.json"
},
{
"url": "https://www.honeywell.com/us/en/contact/support"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Honeywell recommends users contact Honeywell at \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.honeywell.com/us/en/contact/support\"\u003ehttps://www.honeywell.com/us/en/contact/support\u003c/a\u003e for patch information.\u003cbr\u003e"
}
],
"value": "Honeywell recommends users contact Honeywell at https://www.honeywell.com/us/en/contact/support for patch information."
}
],
"source": {
"advisory": "ICSA-26-048-04",
"discovery": "EXTERNAL"
},
"title": "Honeywell CCTV Products Missing Authentication for Critical Function",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-1670",
"datePublished": "2026-02-17T22:56:00.586Z",
"dateReserved": "2026-01-30T00:35:22.440Z",
"dateUpdated": "2026-02-18T20:45:46.226Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-47868 (GCVE-0-2021-47868)
Vulnerability from cvelistv5 – Published: 2026-01-21 17:27 – Updated: 2026-03-05 01:29
VLAI
Title
WIN-PACK PRO 4.8 - 'WPCommandFileService' Unquoted Service Path
Summary
WIN-PACK PRO 4.8 contains an unquoted service path vulnerability in the WPCommandFileService that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\Program Files <x86>\WINPAKPRO\WPCommandFileService Service.exe to inject malicious code that would execute with LocalSystem permissions.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-428 - Unquoted Search Path or Element
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.exploit-db.com/exploits/49692 | exploit |
| https://www.security.honeywell.com/product-reposi… | product |
| https://www.vulncheck.com/advisories/win-pack-pro… | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | WIN-PACK PRO |
Affected:
4.8
|
Date Public
2021-03-16 00:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-47868",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-22T16:47:10.898897Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-22T16:52:36.282Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "WIN-PACK PRO",
"vendor": "Honeywell",
"versions": [
{
"status": "affected",
"version": "4.8"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:honeywell:win-pak:4.8:*:*:*:*:*:*:*",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Alan Mondragon"
}
],
"datePublic": "2021-03-16T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "WIN-PACK PRO 4.8 contains an unquoted service path vulnerability in the WPCommandFileService that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\\Program Files \u003cx86\u003e\\WINPAKPRO\\WPCommandFileService Service.exe to inject malicious code that would execute with LocalSystem permissions."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS"
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "Unquoted Search Path or Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-05T01:29:00.395Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "ExploitDB-49692",
"tags": [
"exploit"
],
"url": "https://www.exploit-db.com/exploits/49692"
},
{
"name": "Honeywell Product Webpage",
"tags": [
"product"
],
"url": "https://www.security.honeywell.com/product-repository/winpak"
},
{
"name": "VulnCheck Advisory: WIN-PACK PRO 4.8 - \u0027WPCommandFileService\u0027 Unquoted Service Path",
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/win-pack-pro-wpcommandfileservice-unquoted-service-path"
}
],
"title": "WIN-PACK PRO 4.8 - \u0027WPCommandFileService\u0027 Unquoted Service Path",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2021-47868",
"datePublished": "2026-01-21T17:27:45.785Z",
"dateReserved": "2026-01-18T12:35:05.171Z",
"dateUpdated": "2026-03-05T01:29:00.395Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-47866 (GCVE-0-2021-47866)
Vulnerability from cvelistv5 – Published: 2026-01-21 17:27 – Updated: 2026-03-05 01:28
VLAI
Title
WIN-PACK PRO 4.8 - 'GuardTourService' Unquoted Service Path
Summary
WIN-PACK PRO 4.8 contains an unquoted service path vulnerability in the GuardTourService that allows local users to potentially execute code with elevated system privileges. Attackers can exploit the unquoted path in C:\Program Files <x86>\WINPAKPRO\WP GuardTour Service.exe to inject malicious code that would execute during service startup.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-428 - Unquoted Search Path or Element
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.exploit-db.com/exploits/49690 | exploit |
| https://www.security.honeywell.com/product-reposi… | product |
| https://www.vulncheck.com/advisories/win-pack-pro… | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | WIN-PACK PRO |
Affected:
4.8
|
Date Public
2021-03-16 00:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-47866",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-22T16:47:15.941886Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-22T16:52:45.690Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "WIN-PACK PRO",
"vendor": "Honeywell",
"versions": [
{
"status": "affected",
"version": "4.8"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:honeywell:win-pak:4.8:*:*:*:*:*:*:*",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Alan Mondragon"
}
],
"datePublic": "2021-03-16T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "WIN-PACK PRO 4.8 contains an unquoted service path vulnerability in the GuardTourService that allows local users to potentially execute code with elevated system privileges. Attackers can exploit the unquoted path in C:\\Program Files \u003cx86\u003e\\WINPAKPRO\\WP GuardTour Service.exe to inject malicious code that would execute during service startup."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS"
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "Unquoted Search Path or Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-05T01:28:59.472Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "ExploitDB-49690",
"tags": [
"exploit"
],
"url": "https://www.exploit-db.com/exploits/49690"
},
{
"name": "Honeywell Product Webpage",
"tags": [
"product"
],
"url": "https://www.security.honeywell.com/product-repository/winpak"
},
{
"name": "VulnCheck Advisory: WIN-PACK PRO 4.8 - \u0027GuardTourService\u0027 Unquoted Service Path",
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/win-pack-pro-guardtourservice-unquoted-service-path"
}
],
"title": "WIN-PACK PRO 4.8 - \u0027GuardTourService\u0027 Unquoted Service Path",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2021-47866",
"datePublished": "2026-01-21T17:27:44.672Z",
"dateReserved": "2026-01-18T12:35:05.170Z",
"dateUpdated": "2026-03-05T01:28:59.472Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-12351 (GCVE-0-2025-12351)
Vulnerability from cvelistv5 – Published: 2025-10-27 15:03 – Updated: 2025-10-27 16:04
VLAI
Title
Inadequate access control measure allows unauthorized users to access restricted administrative functions
Summary
Honeywell S35 Series Cameras contains an authorization bypass Vulnerability through User controller key. An attacker could potentially exploit this vulnerability, leading to Privilege Escalation to admin privileged functionalities . Honeywell also recommends updating to the most recent version of this product, service or offering (S35 Pinhole/Kit Camera to version 2025.08.28, S35 AI Fisheye & Dual Sensor/Micro Dome/Full Color Eyeball & Bullet Camera to version 2025.08.22, S35 Thermal Camera to version 2025.08.26).
Severity
6.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.honeywell.com/us/en/product-security | vendor-advisory |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | S35 3M/5M/8M/Pinhole/Kit Camera |
Affected:
2022.02.28 , < 2025.08.28
(date)
|
|
| Honeywell | S35 AI Fisheye&Dual Sensor/Micro Dome/Full Color Eyeball&Bullet Camera |
Affected:
2024.08.10 , < 2025.08.22
(date)
|
|
| Honeywell | S35 Thermal Camera |
Affected:
2024.10.21 , < 2025.08.26
(date)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-12351",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-27T15:14:48.505227Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-27T16:04:11.466Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Linux"
],
"product": "S35 3M/5M/8M/Pinhole/Kit Camera",
"vendor": "Honeywell",
"versions": [
{
"lessThan": "2025.08.28",
"status": "affected",
"version": "2022.02.28",
"versionType": "date"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Linux"
],
"product": "S35 AI Fisheye\u0026Dual Sensor/Micro Dome/Full Color Eyeball\u0026Bullet Camera",
"vendor": "Honeywell",
"versions": [
{
"lessThan": "2025.08.22",
"status": "affected",
"version": "2024.08.10",
"versionType": "date"
}
]
},
{
"defaultStatus": "unaffected",
"product": "S35 Thermal Camera",
"vendor": "Honeywell",
"versions": [
{
"lessThan": "2025.08.26",
"status": "affected",
"version": "2024.10.21",
"versionType": "date"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Honeywell S35 Series Cameras contains an authorization bypass Vulnerability through User controller key. An attacker could potentially exploit this vulnerability, leading to Privilege Escalation to admin privileged functionalities . Honeywell also recommends updating to the most recent version of this product, service or offering (S35 Pinhole/Kit Camera to version 2025.08.28, S35 AI Fisheye \u0026amp; Dual Sensor/Micro Dome/Full Color Eyeball \u0026amp; Bullet Camera to version 2025.08.22, S35 Thermal Camera to version 2025.08.26).\u003cp\u003e\u003c/p\u003e"
}
],
"value": "Honeywell S35 Series Cameras contains an authorization bypass Vulnerability through User controller key. An attacker could potentially exploit this vulnerability, leading to Privilege Escalation to admin privileged functionalities . Honeywell also recommends updating to the most recent version of this product, service or offering (S35 Pinhole/Kit Camera to version 2025.08.28, S35 AI Fisheye \u0026 Dual Sensor/Micro Dome/Full Color Eyeball \u0026 Bullet Camera to version 2025.08.22, S35 Thermal Camera to version 2025.08.26)."
}
],
"impacts": [
{
"capecId": "CAPEC-22",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-22 Exploiting Trust in Client"
}
]
},
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233 Privilege Escalation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-639",
"description": "CWE-639 Authorization Bypass Through User-Controlled Key",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668 Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-27T15:03:57.602Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.honeywell.com/us/en/product-security"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Inadequate access control measure allows unauthorized users to access restricted administrative functions",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2025-12351",
"datePublished": "2025-10-27T15:03:57.602Z",
"dateReserved": "2025-10-27T14:59:57.822Z",
"dateUpdated": "2025-10-27T16:04:11.466Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3947 (GCVE-0-2025-3947)
Vulnerability from cvelistv5 – Published: 2025-07-10 20:19 – Updated: 2025-08-04 19:46
VLAI
Title
Integer underflow during processing of short network packets in CDA FTEB responder
Summary
The Honeywell Experion PKS contains an Integer Underflow
vulnerability
in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to
Input Data Manipulation, which could result in improper integer data value checking during subtraction leading to a denial of service.
Honeywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1.
The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.
Severity
8.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-191 - Integer Underflow (Wrap or Wraparound)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://process.honeywell.com/ |
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | C300 PCNT02 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300 PCNT05 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM4 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM8 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | UOC |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | CN100 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | HCA |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300PM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C200E |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3947",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-10T20:34:52.670505Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-10T20:35:01.787Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT02",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT05",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM4",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM8",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "UOC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "CN100",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "HCA",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300PM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C200E",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Demid Uzenkov and Kirill Kutaev (Positive Technologies)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Honeywell Experion PKS contains an Integer Underflow \n\nvulnerability \n\nin the component Control\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eData Access (CDA). An attacker could potentially exploit this vulnerability, leading to \n\nInput Data Manipulation, which could result in improper\u0026nbsp;integer data value checking during subtraction leading to a denial of service.\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cbr\u003e\u003c/span\u003e\u003c/span\u003e\n\nHoneywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1.\u003cbr\u003e\u003cbr\u003eThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.\n\n\u003cbr\u003e"
}
],
"value": "The Honeywell Experion PKS contains an Integer Underflow \n\nvulnerability \n\nin the component Control\u00a0Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to \n\nInput Data Manipulation, which could result in improper\u00a0integer data value checking during subtraction leading to a denial of service.\n\n\n\nHoneywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1.\n\nThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3."
}
],
"impacts": [
{
"capecId": "CAPEC-153",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-153 Input Data Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-191",
"description": "CWE-191 Integer Underflow (Wrap or Wraparound)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T19:46:31.982Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Integer underflow during processing of short network packets in CDA FTEB responder",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2025-3947",
"datePublished": "2025-07-10T20:19:13.991Z",
"dateReserved": "2025-04-25T15:21:22.614Z",
"dateUpdated": "2025-08-04T19:46:31.982Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3946 (GCVE-0-2025-3946)
Vulnerability from cvelistv5 – Published: 2025-07-10 20:16 – Updated: 2025-08-04 19:46
VLAI
Title
Incorrect response generation during FTEB protocol processing
Summary
The Honeywell Experion PKS
and OneWireless WDM
contains a Deployment of Wrong Handler
vulnerability
in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to
Input Data Manipulation,
which could result in incorrect handling of packets leading to remote code execution.
Honeywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.
The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.
Severity
8.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-430 - Deployment of Wrong Handler
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://process.honeywell.com/ |
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | C300 PCNT02 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300 PCNT05 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM4 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM8 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | UOC |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | CN100 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | HCA |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300PM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C200E |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | Wireless Device Manager |
Affected:
322.1 , ≤ 322.4
(semver)
Affected: 330.1 , ≤ 330.3 (semver) |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3946",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-10T20:35:19.798404Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-10T20:35:28.409Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT02",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT05",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM4",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM8",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "UOC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "CN100",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "HCA",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300PM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C200E",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"OneWireless"
],
"product": "Wireless Device Manager",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "322.4",
"status": "affected",
"version": "322.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "330.3",
"status": "affected",
"version": "330.1",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Demid Uzenkov and Kirill Kutaev (Positive Technologies)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Honeywell Experion PKS \n\nand OneWireless WDM\n\ncontains a Deployment of Wrong Handler\n\n \n\nvulnerability \n\nin the component Control\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eData Access (CDA). An attacker could potentially exploit this vulnerability, leading to \n\nInput Data Manipulation, \n\n which could result in incorrect handling of packets leading to remote code execution.\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cbr\u003e\u003cbr\u003e\n\nHoneywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.\u003cbr\u003e\u003cbr\u003eThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.\u003c/span\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.\n\n\u003cbr\u003e\u003c/span\u003e"
}
],
"value": "The Honeywell Experion PKS \n\nand OneWireless WDM\n\ncontains a Deployment of Wrong Handler\n\n \n\nvulnerability \n\nin the component Control\u00a0Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to \n\nInput Data Manipulation, \n\n which could result in incorrect handling of packets leading to remote code execution.\n\n\n\nHoneywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.\n\nThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.\u00a0The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3."
}
],
"impacts": [
{
"capecId": "CAPEC-153",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-153 Input Data Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-430",
"description": "CWE-430 Deployment of Wrong Handler",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T19:46:15.112Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Incorrect response generation during FTEB protocol processing",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2025-3946",
"datePublished": "2025-07-10T20:16:54.743Z",
"dateReserved": "2025-04-25T15:21:21.740Z",
"dateUpdated": "2025-08-04T19:46:15.112Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2523 (GCVE-0-2025-2523)
Vulnerability from cvelistv5 – Published: 2025-07-10 20:15 – Updated: 2025-08-04 19:45
VLAI
Title
Lack of buffer clearing before reuse may result in incorrect system behavior.
Summary
The Honeywell Experion PKS
and OneWireless WDM
contains an Integer Underflow
vulnerability
in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in a failure during subtraction allowing remote code execution.
Honeywell recommends updating to the most recent version of
Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.
The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.
Severity
9.4 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-191 - Integer Underflow (Wrap or Wraparound)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://process.honeywell.com/ |
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | C300 PCNT02 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300 PCNT05 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM4 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM8 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | UOC |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | CN100 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | HCA |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300PM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C200E |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | Wireless Device Manager |
Affected:
322.1 , ≤ 322.4
(semver)
Affected: 330.1 , ≤ 330.3 (semver) |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2523",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-10T20:35:45.591675Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-10T20:35:53.232Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT02",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT05",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM4",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM8",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "UOC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "CN100",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "HCA",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300PM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C200E",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"OneWireless"
],
"product": "Wireless Device Manager",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "322.4",
"status": "affected",
"version": "322.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "330.3",
"status": "affected",
"version": "330.1",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Demid Uzenkov and Kirill Kutaev (Positive Technologies)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Honeywell Experion PKS \n\n and OneWireless WDM \n\ncontains an Integer Underflow \n\nvulnerability \n\nin the component Control\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eData Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in a failure\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;during subtraction allowing remote code execution.\u003c/span\u003e\u003c/span\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cbr\u003e\u003cbr\u003eHoneywell recommends updating to the most recent version of \n\nHoneywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.\u003cbr\u003e\u003c/span\u003e\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\nThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.\n\n\u003c/span\u003e\u003cbr\u003e"
}
],
"value": "The Honeywell Experion PKS \n\n and OneWireless WDM \n\ncontains an Integer Underflow \n\nvulnerability \n\nin the component Control\u00a0Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in a failure\u00a0during subtraction allowing remote code execution.\n\n\n\nHoneywell recommends updating to the most recent version of \n\nHoneywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.\n\n\n\nThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3."
}
],
"impacts": [
{
"capecId": "CAPEC-216",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-216 Communication Channel Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-191",
"description": "CWE-191 Integer Underflow (Wrap or Wraparound)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T19:45:51.105Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Lack of buffer clearing before reuse may result in incorrect system behavior.",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2025-2523",
"datePublished": "2025-07-10T20:15:32.600Z",
"dateReserved": "2025-03-19T13:57:31.419Z",
"dateUpdated": "2025-08-04T19:45:51.105Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2522 (GCVE-0-2025-2522)
Vulnerability from cvelistv5 – Published: 2025-07-10 20:11 – Updated: 2025-08-04 19:45
VLAI
Title
Lack of buffer clearing before reuse may result in incorrect system behavior.
Summary
The Honeywell Experion PKS and OneWireless WDM
contains Sensitive Information in Resource vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in buffer reuse which may cause incorrect system behavior.
Honeywell also recommends updating to the most recent version of
Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.
The affected Experion PKS products are
C300, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are 520.1 before
520.2 TCU9 HF1 and 530 before 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-226 - Sensitive Information in Resource Not Removed Before Reuse
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://process.honeywell.com/ |
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | C300 PCNT02 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300 PCNT05 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM4 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM8 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | UOC |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | CN100 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | HCA |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300PM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C200E |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | Wireless Device Manager |
Affected:
322.1 , ≤ 322.4
(semver)
Affected: 330.1 , ≤ 330.3 (semver) |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2522",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-10T20:34:00.516806Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-10T20:34:08.789Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT02",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT05",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM4",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM8",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "UOC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "CN100",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "HCA",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300PM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C200E",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"OneWireless"
],
"product": "Wireless Device Manager",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "322.4",
"status": "affected",
"version": "322.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "330.3",
"status": "affected",
"version": "330.1",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Demid Uzenkov and Kirill Kutaev (Positive Technologies)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Honeywell Experion PKS\u0026nbsp;and OneWireless WDM \n\n contains Sensitive Information in Resource vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in buffer reuse which may cause incorrect system behavior.\n\n\u003cp\u003eHoneywell also recommends updating to the most recent version of \n\nHoneywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.\u0026nbsp;\u003c/p\u003e\u003cp\u003eThe affected Experion PKS products are \n\n\n\nC300, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are 520.1 before \n\n520.2 TCU9 HF1 and 530 before 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.\u003c/p\u003e"
}
],
"value": "The Honeywell Experion PKS\u00a0and OneWireless WDM \n\n contains Sensitive Information in Resource vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in buffer reuse which may cause incorrect system behavior.\n\nHoneywell also recommends updating to the most recent version of \n\nHoneywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.\u00a0\n\nThe affected Experion PKS products are \n\n\n\nC300, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are 520.1 before \n\n520.2 TCU9 HF1 and 530 before 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3."
}
],
"impacts": [
{
"capecId": "CAPEC-216",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-216 Communication Channel Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-226",
"description": "CWE-226 Sensitive Information in Resource Not Removed Before Reuse",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T19:45:13.439Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Lack of buffer clearing before reuse may result in incorrect system behavior.",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2025-2522",
"datePublished": "2025-07-10T20:11:43.603Z",
"dateReserved": "2025-03-19T13:57:30.424Z",
"dateUpdated": "2025-08-04T19:45:13.439Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2521 (GCVE-0-2025-2521)
Vulnerability from cvelistv5 – Published: 2025-07-10 20:08 – Updated: 2025-08-04 19:44
VLAI
Title
Lack of indexes’ validation against buffer borders leads to remote code execution.
Summary
The Honeywell Experion PKS and OneWireless WDM contains a Memory Buffer vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to an Overread Buffers, which could result in improper index validation against buffer borders leading to remote code execution.
Honeywell recommends updating to the most recent version of Honeywell Experion PKS:
520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.
The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.
Severity
8.6 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://process.honeywell.com/ |
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | C300 PCNT02 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300 PCNT05 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM4 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM8 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | UOC |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | CN100 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | HCA |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C300PM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | C200E |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | Wireless Device Manager |
Affected:
322.1 , ≤ 322.4
(semver)
Affected: 330.1 , ≤ 330.3 (semver) |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2521",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-10T20:33:41.946048Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-10T20:33:49.166Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT02",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT05",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM4",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM8",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "UOC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "CN100",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "HCA",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300PM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C200E",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"OneWireless"
],
"product": "Wireless Device Manager",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "322.4",
"status": "affected",
"version": "322.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "330.3",
"status": "affected",
"version": "330.1",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Demid Uzenkov and Kirill Kutaev (Positive Technologies)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThe Honeywell Experion PKS and OneWireless WDM contains a Memory Buffer vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to an Overread Buffers, which could result in improper index validation against buffer borders leading to remote code execution.\u003c/p\u003e\u003cp\u003eHoneywell recommends updating to the most recent version of Honeywell Experion PKS:\n\n520.2 TCU9 HF1 and\u0026nbsp;530.1 TCU3 HF1 and OneWireless:\u0026nbsp;322.5 and 331.1.\u003c/p\u003e\u003cp\u003e\u003cbr\u003eThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.\u003c/p\u003e"
}
],
"value": "The Honeywell Experion PKS and OneWireless WDM contains a Memory Buffer vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to an Overread Buffers, which could result in improper index validation against buffer borders leading to remote code execution.\n\nHoneywell recommends updating to the most recent version of Honeywell Experion PKS:\n\n520.2 TCU9 HF1 and\u00a0530.1 TCU3 HF1 and OneWireless:\u00a0322.5 and 331.1.\n\n\nThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3."
}
],
"impacts": [
{
"capecId": "CAPEC-540",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-540 Overread Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T19:44:27.744Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Lack of indexes\u2019 validation against buffer borders leads to remote code execution.",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2025-2521",
"datePublished": "2025-07-10T20:08:04.077Z",
"dateReserved": "2025-03-19T13:57:29.165Z",
"dateUpdated": "2025-08-04T19:44:27.744Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2520 (GCVE-0-2025-2520)
Vulnerability from cvelistv5 – Published: 2025-07-10 19:54 – Updated: 2025-08-04 19:44
VLAI
Title
Dereferencing of an uninitialized pointer leads to denial of service.
Summary
The Honeywell Experion PKS contains an Uninitialized Variable in the common Epic Platform Analyzer (EPA) communications. An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which results in a dereferencing of an uninitialized pointer leading to a denial of service.
Honeywell recommends updating to the most recent version of
Honeywell Experion PKS: 520.2 TCU9 HF1and 530.1 TCU3 HF1. The affected Experion PKS products are
C300 PCNT02, EHB, EHPM, ELMM, Classic ENIM, ETN, FIM4, FIM8, PGM, and RFIM. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-457 - Use of Uninitialized Variable
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://process.honeywell.com/ |
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | C300 PCNT02 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | EHB |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | EHPM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | ELMM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | Classic ENIM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | ETN |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM4 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | FIM8 |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | PGM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
|
| Honeywell | RFIM |
Affected:
520.1 , ≤ 520.2 TCU9
(semver)
Affected: 530 , ≤ 530 TCU3 (semver) |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2520",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-10T20:33:19.670618Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-10T20:33:30.482Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300 PCNT02",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "EHB",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "EHPM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "ELMM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "Classic ENIM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "ETN",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM4",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "FIM8",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "PGM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "RFIM",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU9",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "530 TCU3",
"status": "affected",
"version": "530",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Demid Uzenkov and Kirill Kutaev (Positive Technologies)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe Honeywell Experion PKS contains an \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUninitialized Variable i\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003en the common Epic Platform Analyzer (EPA) communications\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e. An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which results in a d\u003c/span\u003eereferencing of an uninitialized pointer leading to a denial of service.\u003cbr\u003e\u003cbr\u003e\n\nHoneywell recommends updating to the most recent version of \n\nHoneywell Experion PKS: 520.2 TCU9 HF1and\u0026nbsp;530.1 TCU3 HF1.\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe affected Experion PKS products are \n\nC300 PCNT02, EHB, EHPM, ELMM, Classic ENIM, ETN, FIM4, FIM8, PGM, and RFIM. The Experion PKS versions affected are\u0026nbsp;from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.\u003c/span\u003e\u003cbr\u003e"
}
],
"value": "The Honeywell Experion PKS contains an Uninitialized Variable in the common Epic Platform Analyzer (EPA) communications. An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which results in a dereferencing of an uninitialized pointer leading to a denial of service.\n\n\n\nHoneywell recommends updating to the most recent version of \n\nHoneywell Experion PKS: 520.2 TCU9 HF1and\u00a0530.1 TCU3 HF1.\u00a0The affected Experion PKS products are \n\nC300 PCNT02, EHB, EHPM, ELMM, Classic ENIM, ETN, FIM4, FIM8, PGM, and RFIM. The Experion PKS versions affected are\u00a0from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3."
}
],
"impacts": [
{
"capecId": "CAPEC-216",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-216 Communication Channel Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-457",
"description": "CWE-457 Use of Uninitialized Variable",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T19:44:48.506Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Dereferencing of an uninitialized pointer leads to denial of service.",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2025-2520",
"datePublished": "2025-07-10T19:54:35.250Z",
"dateReserved": "2025-03-19T13:57:27.868Z",
"dateUpdated": "2025-08-04T19:44:48.506Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2605 (GCVE-0-2025-2605)
Vulnerability from cvelistv5 – Published: 2025-05-02 12:39 – Updated: 2025-05-17 06:03
VLAI
Title
Authenticated command injection
Summary
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product.
Severity
9.9 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.honeywell.com/us/en/product-security#… | vendor-advisory |
| http://seclists.org/fulldisclosure/2025/May/19 |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2605",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-02T13:32:21.228869Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-02T13:32:33.807Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-05-17T06:03:36.347Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/May/19"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "MB-Secure",
"vendor": "Honeywell",
"versions": [
{
"lessThan": "V12.53",
"status": "affected",
"version": "V11.04",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product."
}
],
"value": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product."
}
],
"impacts": [
{
"capecId": "CAPEC-122",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-122 Privilege Abuse"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-02T12:39:39.979Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.honeywell.com/us/en/product-security#security-notices"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Authenticated command injection",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2025-2605",
"datePublished": "2025-05-02T12:39:39.979Z",
"dateReserved": "2025-03-21T13:18:29.509Z",
"dateUpdated": "2025-05-17T06:03:36.347Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-5878 (GCVE-0-2023-5878)
Vulnerability from cvelistv5 – Published: 2025-02-06 14:10 – Updated: 2025-02-18 18:13
VLAI
Title
OneWireless command injection possible when updating firmware
Summary
Honeywell OneWireless
Wireless Device Manager (WDM) for the following versions R310.x, R320.x, R321.x, R322.1, R322.2, R323.x, R330.1 contains a command injection vulnerability. An attacker who is authenticated could use the firmware update process to potentially exploit the vulnerability, leading to a command injection. Honeywell recommends updating to
R322.3, R330.2 or the most recent version of this product2.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://process.honeywell.com/ |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | OneWireless Network Wireless Device Manager |
Affected:
310.1 , ≤ 322.2
(semver)
Affected: 323.1 , ≤ 330.1 (semver) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5878",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-06T14:26:15.468750Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-18T18:13:44.990Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Linux"
],
"product": "OneWireless Network Wireless Device Manager",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "322.2",
"status": "affected",
"version": "310.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "330.1",
"status": "affected",
"version": "323.1",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eHoneywell OneWireless \n\nWireless Device Manager (WDM)\u0026nbsp;for the following versions R310.x, R320.x, R321.x, R322.1, R322.2, R323.x, R330.1 contains a command injection vulnerability. An attacker who is authenticated could use the firmware update process to potentially exploit the vulnerability, leading to a command injection. Honeywell recommends updating to \n\n R322.3, R330.2 or the most recent version of this product2.\n\n\u003c/span\u003e\u003cbr\u003e"
}
],
"value": "Honeywell OneWireless \n\nWireless Device Manager (WDM)\u00a0for the following versions R310.x, R320.x, R321.x, R322.1, R322.2, R323.x, R330.1 contains a command injection vulnerability. An attacker who is authenticated could use the firmware update process to potentially exploit the vulnerability, leading to a command injection. Honeywell recommends updating to \n\n R322.3, R330.2 or the most recent version of this product2."
}
],
"impacts": [
{
"capecId": "CAPEC-248",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-248 Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-06T14:10:30.295Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "OneWireless command injection possible when updating firmware",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2023-5878",
"datePublished": "2025-02-06T14:10:30.295Z",
"dateReserved": "2023-10-31T13:16:00.514Z",
"dateUpdated": "2025-02-18T18:13:44.990Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-6620 (GCVE-0-2024-6620)
Vulnerability from cvelistv5 – Published: 2024-07-29 20:14 – Updated: 2024-08-01 21:41
VLAI
Summary
Honeywell PC42t, PC42tp, and PC42d Printers, T10.19.020016 to T10.20.060398, contain a cross-site scripting vulnerability. A(n) attacker could potentially inject malicious code which may lead to information disclosure, session theft, or client-side request forgery. Honeywell recommends updating to the most recent version of this firmware, PC42 Printer Firmware Version 20.6 T10.20.060398.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://sps.honeywell.com/us/en/support/productiv… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | PC42t, PC42tp, and PC42d (Common Firmware) |
Affected:
T10.19.020016 , < T10.20.060398
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-6620",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-30T14:17:52.818483Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-30T14:17:59.561Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:41:03.974Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://sps.honeywell.com/us/en/support/productivity/cyber-security-notifications"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PC42t, PC42tp, and PC42d (Common Firmware)",
"vendor": "Honeywell",
"versions": [
{
"changes": [
{
"at": "T10.20.060398",
"status": "unaffected"
}
],
"lessThan": "T10.20.060398",
"status": "affected",
"version": "T10.19.020016",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Honeywell PC42t, PC42tp, and PC42d Printers, T10.19.020016 to T10.20.060398, contain a cross-site scripting vulnerability. A(n) attacker could potentially inject malicious code which may lead to information disclosure, session theft, or client-side request forgery. Honeywell recommends updating to the most recent version of this firmware, PC42 Printer Firmware Version 20.6 T10.20.060398."
}
],
"value": "Honeywell PC42t, PC42tp, and PC42d Printers, T10.19.020016 to T10.20.060398, contain a cross-site scripting vulnerability. A(n) attacker could potentially inject malicious code which may lead to information disclosure, session theft, or client-side request forgery. Honeywell recommends updating to the most recent version of this firmware, PC42 Printer Firmware Version 20.6 T10.20.060398."
}
],
"impacts": [
{
"capecId": "CAPEC-63",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-63 Cross-Site Scripting (XSS)"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-602",
"description": "CWE-602",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-29T20:14:27.666Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://sps.honeywell.com/us/en/support/productivity/cyber-security-notifications"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2024-6620",
"datePublished": "2024-07-29T20:14:27.666Z",
"dateReserved": "2024-07-09T15:50:58.050Z",
"dateUpdated": "2024-08-01T21:41:03.974Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}