    CVE-2026-4272 (GCVE-0-2026-4272)

    Vulnerability from cvelistv5 – Published: 2026-04-05 22:00 – Updated: 2026-04-06 14:01
    VLAI
    Title
    CVE-2026-4272 - Bluetooth Remote Execution of System Commands Vulnerability
    Summary
    Missing Authentication for Critical Function vulnerability in Honeywell Handheld Scanners allows Authentication Abuse.This issue affects Handheld Scanners: from C1 Base(Ingenic x1000) before GK000432BAA, from D1 Base(Ingenic x1600) before HE000085BAA, from A1/B1 Base(IMX25) before BK000763BAA_BK000765BAA_CU000101BAA. This vulnerability could allow a remote attacker within Bluetooth range of the scanner's base station has the capability to remotely execute system commands on the host connected to the base station without authentication. This issue has been assigned  CVE-2026-4272 https://nvd.nist.gov/vuln/detail/CVE-2026-4272 and rated with a severity of High. Honeywell strongly recommends that users upgrade to the latest version identified to resolve the vulnerability.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Vendor Product Version
    Honeywell Barcode Scanners Affected: C1 Base(Ingenic x1000) , < GK000432BAA (custom)
    Affected: D1 Base(Ingenic x1600) , < HE000085BAA (custom)
    Affected: A1/B1 Base(IMX25) , < BK000763BAA_BK000765BAA_CU000101BAA (custom)
    Create a notification for this product.
    Credits
    Kaspersky Haidar Kabibo
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-4272",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-06T14:00:57.144252Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-06T14:01:35.115Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Barcode Scanners",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThan": "GK000432BAA",
                  "status": "affected",
                  "version": "C1 Base(Ingenic x1000)",
                  "versionType": "custom"
                },
                {
                  "lessThan": "HE000085BAA",
                  "status": "affected",
                  "version": "D1 Base(Ingenic x1600)",
                  "versionType": "custom"
                },
                {
                  "lessThan": "BK000763BAA_BK000765BAA_CU000101BAA",
                  "status": "affected",
                  "version": "A1/B1 Base(IMX25)",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Kaspersky"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Haidar Kabibo"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Missing Authentication for Critical Function vulnerability in Honeywell Handheld Scanners allows Authentication Abuse.\u003cp\u003eThis issue affects Handheld Scanners: from C1 Base(Ingenic x1000) before GK000432BAA, from D1 Base(Ingenic x1600) before HE000085BAA, from A1/B1 Base(IMX25) before BK000763BAA_BK000765BAA_CU000101BAA.\u003c/p\u003eThis vulnerability could allow a remote attacker within Bluetooth range of the scanner\u0027s base station has the capability to remotely execute system commands on the host connected to the base station without authentication. This issue has been assigned\u0026nbsp;\u003ca href=\"https://nvd.nist.gov/vuln/detail/CVE-2026-4272\"\u003eCVE-2026-4272\u003c/a\u003e and rated with a severity of High. Honeywell strongly recommends that users upgrade to the latest version identified to resolve the vulnerability.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Missing Authentication for Critical Function vulnerability in Honeywell Handheld Scanners allows Authentication Abuse.This issue affects Handheld Scanners: from C1 Base(Ingenic x1000) before GK000432BAA, from D1 Base(Ingenic x1600) before HE000085BAA, from A1/B1 Base(IMX25) before BK000763BAA_BK000765BAA_CU000101BAA.\n\nThis vulnerability could allow a remote attacker within Bluetooth range of the scanner\u0027s base station has the capability to remotely execute system commands on the host connected to the base station without authentication. This issue has been assigned\u00a0 CVE-2026-4272 https://nvd.nist.gov/vuln/detail/CVE-2026-4272  and rated with a severity of High. Honeywell strongly recommends that users upgrade to the latest version identified to resolve the vulnerability."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-114",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-114 Authentication Abuse"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-05T22:00:27.141Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "url": "https://https://nvd.nist.gov/vuln/detail/CVE-2026-4272"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "CVE-2026-4272 - Bluetooth Remote Execution of System Commands Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2026-4272",
        "datePublished": "2026-04-05T22:00:27.141Z",
        "dateReserved": "2026-03-16T14:45:35.186Z",
        "dateUpdated": "2026-04-06T14:01:35.115Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-3611 (GCVE-0-2026-3611)

    Vulnerability from cvelistv5 – Published: 2026-03-12 20:06 – Updated: 2026-03-30 15:26
    VLAI
    Title
    Honeywell IQ4x BMS Controller Missing authentication for critical function
    Summary
    The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 100) context, granting read/write privileges to any party able to reach the HTTP interface. Authentication controls are only enforced after a web user is created via U.htm, which dynamically enables the user module. Because this function is accessible prior to authentication, a remote user can create a new account with administrative read/write permissions enabling the user module and imposing authentication under attacker-controlled credentials. This action can effectively lock legitimate operators out of local and web-based configuration and administration.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing authentication for critical function
    Assigner
    Impacted products
    Vendor Product Version
    Honeywell IQ4E Affected: v3.50_3.44 , ≤ 4.36 (build 4.3.7.9) (custom)
    Create a notification for this product.
    Honeywell IQ412 Affected: v3.50_3.44 , ≤ 4.36 (build 4.3.7.9) (custom)
    Create a notification for this product.
    Honeywell IQ422 Affected: v3.50_3.44 , ≤ 4.36 (build 4.3.7.9) (custom)
    Create a notification for this product.
    Honeywell IQ4NC Affected: v3.50_3.44 , ≤ 4.36 (build 4.3.7.9) (custom)
    Create a notification for this product.
    Honeywell IQ41x Affected: v3.50_3.44 , ≤ 4.36 (build 4.3.7.9) (custom)
    Create a notification for this product.
    Honeywell IQ3 Affected: v3.50_3.44 , ≤ 4.36 (build 4.3.7.9) (custom)
    Create a notification for this product.
    Honeywell IQECO Affected: v3.50_3.44 , ≤ 4.36 (build 4.3.7.9) (custom)
    Create a notification for this product.
    Date Public
    2026-03-10 17:00
    Credits
    Gjoko Krstic of Zero Science reported this vulnerability to Honeywell.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-3611",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-13T18:02:46.954644Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-13T18:03:02.081Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "IQ4E",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "4.36 (build 4.3.7.9)",
                  "status": "affected",
                  "version": "v3.50_3.44",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "IQ412",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "4.36 (build 4.3.7.9)",
                  "status": "affected",
                  "version": "v3.50_3.44",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "IQ422",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "4.36 (build 4.3.7.9)",
                  "status": "affected",
                  "version": "v3.50_3.44",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "IQ4NC",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "4.36 (build 4.3.7.9)",
                  "status": "affected",
                  "version": "v3.50_3.44",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "IQ41x",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "4.36 (build 4.3.7.9)",
                  "status": "affected",
                  "version": "v3.50_3.44",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "IQ3",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "4.36 (build 4.3.7.9)",
                  "status": "affected",
                  "version": "v3.50_3.44",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "IQECO",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "4.36 (build 4.3.7.9)",
                  "status": "affected",
                  "version": "v3.50_3.44",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gjoko Krstic of Zero Science reported this vulnerability to Honeywell."
            }
          ],
          "datePublic": "2026-03-10T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 100) context, granting read/write privileges to any party able to reach the HTTP interface. Authentication controls are only enforced after a web user is created via U.htm, which dynamically enables the user module. Because this function is accessible prior to authentication, a remote user can create a new account with administrative read/write permissions enabling the user module and imposing authentication under attacker-controlled credentials. This action can effectively lock legitimate operators out of local and web-based configuration and administration."
                }
              ],
              "value": "The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 100) context, granting read/write privileges to any party able to reach the HTTP interface. Authentication controls are only enforced after a web user is created via U.htm, which dynamically enables the user module. Because this function is accessible prior to authentication, a remote user can create a new account with administrative read/write permissions enabling the user module and imposing authentication under attacker-controlled credentials. This action can effectively lock legitimate operators out of local and web-based configuration and administration."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing authentication for critical function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-30T15:26:08.604Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-069-03"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-069-03.json"
            },
            {
              "url": "https://www.honeywell.com/us/en/contact"
            }
          ],
          "source": {
            "advisory": "ICSA-26-069-03",
            "discovery": "EXTERNAL"
          },
          "title": "Honeywell IQ4x BMS Controller Missing authentication for critical function",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Honeywell is aware of the issue, but has not released a fix. For more \ninformation, contact Honeywell directly. \n[https://www.honeywell.com/us/en/contact](https://www.honeywell.com/us/en/contact)."
                }
              ],
              "value": "Honeywell is aware of the issue, but has not released a fix. For more \ninformation, contact Honeywell directly. \n[https://www.honeywell.com/us/en/contact](https://www.honeywell.com/us/en/contact)."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 1.0.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-3611",
        "datePublished": "2026-03-12T20:06:05.753Z",
        "dateReserved": "2026-03-05T18:12:38.425Z",
        "dateUpdated": "2026-03-30T15:26:08.604Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-1670 (GCVE-0-2026-1670)

    Vulnerability from cvelistv5 – Published: 2026-02-17 22:56 – Updated: 2026-02-18 20:45
    VLAI
    Title
    Honeywell CCTV Products Missing Authentication for Critical Function
    Summary
    The affected products are vulnerable to an unauthenticated API endpoint exposure, which may allow an attacker to remotely change the "forgot password" recovery email address.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Date Public
    2026-02-17 17:00
    Credits
    Souvik Kandar reported this vulnerability to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-1670",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-18T20:45:37.144272Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-18T20:45:46.226Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "I-HIB2PI-UL 2MP IP",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.1.22.1216"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SMB NDAA MVO-3",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "WDR_2MP_32M_PTZ_v2.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PTZ WDR 2MP 32M",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "WDR_2MP_32M_PTZ_v2.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "25M IPC",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "WDR_2MP_32M_PTZ_v2.0"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Souvik Kandar reported this vulnerability to CISA."
            }
          ],
          "datePublic": "2026-02-17T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The affected products are vulnerable to an unauthenticated API endpoint exposure, which may allow an attacker to remotely change the \"forgot password\" recovery email address."
                }
              ],
              "value": "The affected products are vulnerable to an unauthenticated API endpoint exposure, which may allow an attacker to remotely change the \"forgot password\" recovery email address."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-17T22:56:00.586Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-048-04"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-048-04.json"
            },
            {
              "url": "https://www.honeywell.com/us/en/contact/support"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Honeywell recommends users contact Honeywell at \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.honeywell.com/us/en/contact/support\"\u003ehttps://www.honeywell.com/us/en/contact/support\u003c/a\u003e for patch information.\u003cbr\u003e"
                }
              ],
              "value": "Honeywell recommends users contact Honeywell at  https://www.honeywell.com/us/en/contact/support  for patch information."
            }
          ],
          "source": {
            "advisory": "ICSA-26-048-04",
            "discovery": "EXTERNAL"
          },
          "title": "Honeywell CCTV Products Missing Authentication for Critical Function",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-1670",
        "datePublished": "2026-02-17T22:56:00.586Z",
        "dateReserved": "2026-01-30T00:35:22.440Z",
        "dateUpdated": "2026-02-18T20:45:46.226Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-47868 (GCVE-0-2021-47868)

    Vulnerability from cvelistv5 – Published: 2026-01-21 17:27 – Updated: 2026-03-05 01:29
    VLAI
    Title
    WIN-PACK PRO 4.8 - 'WPCommandFileService' Unquoted Service Path
    Summary
    WIN-PACK PRO 4.8 contains an unquoted service path vulnerability in the WPCommandFileService that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\Program Files <x86>\WINPAKPRO\WPCommandFileService Service.exe to inject malicious code that would execute with LocalSystem permissions.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-428 - Unquoted Search Path or Element
    Assigner
    Impacted products
    Date Public
    2021-03-16 00:00
    Credits
    Alan Mondragon
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-47868",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-22T16:47:10.898897Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-22T16:52:36.282Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "WIN-PACK PRO",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.8"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:honeywell:win-pak:4.8:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Alan Mondragon"
            }
          ],
          "datePublic": "2021-03-16T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "WIN-PACK PRO 4.8 contains an unquoted service path vulnerability in the WPCommandFileService that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\\Program Files \u003cx86\u003e\\WINPAKPRO\\WPCommandFileService Service.exe to inject malicious code that would execute with LocalSystem permissions."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS"
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-428",
                  "description": "Unquoted Search Path or Element",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-05T01:29:00.395Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "ExploitDB-49692",
              "tags": [
                "exploit"
              ],
              "url": "https://www.exploit-db.com/exploits/49692"
            },
            {
              "name": "Honeywell Product Webpage",
              "tags": [
                "product"
              ],
              "url": "https://www.security.honeywell.com/product-repository/winpak"
            },
            {
              "name": "VulnCheck Advisory: WIN-PACK PRO 4.8 - \u0027WPCommandFileService\u0027 Unquoted Service Path",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/win-pack-pro-wpcommandfileservice-unquoted-service-path"
            }
          ],
          "title": "WIN-PACK PRO 4.8 - \u0027WPCommandFileService\u0027 Unquoted Service Path",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2021-47868",
        "datePublished": "2026-01-21T17:27:45.785Z",
        "dateReserved": "2026-01-18T12:35:05.171Z",
        "dateUpdated": "2026-03-05T01:29:00.395Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-47866 (GCVE-0-2021-47866)

    Vulnerability from cvelistv5 – Published: 2026-01-21 17:27 – Updated: 2026-03-05 01:28
    VLAI
    Title
    WIN-PACK PRO 4.8 - 'GuardTourService' Unquoted Service Path
    Summary
    WIN-PACK PRO 4.8 contains an unquoted service path vulnerability in the GuardTourService that allows local users to potentially execute code with elevated system privileges. Attackers can exploit the unquoted path in C:\Program Files <x86>\WINPAKPRO\WP GuardTour Service.exe to inject malicious code that would execute during service startup.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-428 - Unquoted Search Path or Element
    Assigner
    Impacted products
    Date Public
    2021-03-16 00:00
    Credits
    Alan Mondragon
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-47866",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-22T16:47:15.941886Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-22T16:52:45.690Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "WIN-PACK PRO",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.8"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:honeywell:win-pak:4.8:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Alan Mondragon"
            }
          ],
          "datePublic": "2021-03-16T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "WIN-PACK PRO 4.8 contains an unquoted service path vulnerability in the GuardTourService that allows local users to potentially execute code with elevated system privileges. Attackers can exploit the unquoted path in C:\\Program Files \u003cx86\u003e\\WINPAKPRO\\WP GuardTour Service.exe to inject malicious code that would execute during service startup."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS"
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-428",
                  "description": "Unquoted Search Path or Element",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-05T01:28:59.472Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "ExploitDB-49690",
              "tags": [
                "exploit"
              ],
              "url": "https://www.exploit-db.com/exploits/49690"
            },
            {
              "name": "Honeywell Product Webpage",
              "tags": [
                "product"
              ],
              "url": "https://www.security.honeywell.com/product-repository/winpak"
            },
            {
              "name": "VulnCheck Advisory: WIN-PACK PRO 4.8 - \u0027GuardTourService\u0027 Unquoted Service Path",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/win-pack-pro-guardtourservice-unquoted-service-path"
            }
          ],
          "title": "WIN-PACK PRO 4.8 - \u0027GuardTourService\u0027 Unquoted Service Path",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2021-47866",
        "datePublished": "2026-01-21T17:27:44.672Z",
        "dateReserved": "2026-01-18T12:35:05.170Z",
        "dateUpdated": "2026-03-05T01:28:59.472Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-12351 (GCVE-0-2025-12351)

    Vulnerability from cvelistv5 – Published: 2025-10-27 15:03 – Updated: 2025-10-27 16:04
    VLAI
    Title
    Inadequate access control measure allows unauthorized users to access restricted administrative functions
    Summary
    Honeywell S35 Series Cameras contains an authorization bypass Vulnerability through User controller key. An attacker could potentially exploit this vulnerability, leading to Privilege Escalation to admin privileged functionalities . Honeywell also recommends updating to the most recent version of this product, service or offering (S35 Pinhole/Kit Camera to version 2025.08.28, S35 AI Fisheye & Dual Sensor/Micro Dome/Full Color Eyeball & Bullet Camera to version 2025.08.22, S35 Thermal Camera to version 2025.08.26).
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-639 - Authorization Bypass Through User-Controlled Key
    • CWE-668 - Exposure of Resource to Wrong Sphere
    Assigner
    References
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-12351",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-27T15:14:48.505227Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-27T16:04:11.466Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Linux"
              ],
              "product": "S35 3M/5M/8M/Pinhole/Kit Camera",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThan": "2025.08.28",
                  "status": "affected",
                  "version": "2022.02.28",
                  "versionType": "date"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Linux"
              ],
              "product": "S35 AI Fisheye\u0026Dual Sensor/Micro Dome/Full Color Eyeball\u0026Bullet Camera",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThan": "2025.08.22",
                  "status": "affected",
                  "version": "2024.08.10",
                  "versionType": "date"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "S35 Thermal Camera",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThan": "2025.08.26",
                  "status": "affected",
                  "version": "2024.10.21",
                  "versionType": "date"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Honeywell S35 Series Cameras contains an authorization bypass Vulnerability through User controller key. An attacker could potentially exploit this vulnerability, leading to Privilege Escalation to admin privileged functionalities . Honeywell also recommends updating to the most recent version of this product, service or offering (S35 Pinhole/Kit Camera to version 2025.08.28, S35 AI Fisheye \u0026amp; Dual Sensor/Micro Dome/Full Color Eyeball \u0026amp; Bullet Camera to version 2025.08.22, S35 Thermal Camera to version 2025.08.26).\u003cp\u003e\u003c/p\u003e"
                }
              ],
              "value": "Honeywell S35 Series Cameras contains an authorization bypass Vulnerability through User controller key. An attacker could potentially exploit this vulnerability, leading to Privilege Escalation to admin privileged functionalities . Honeywell also recommends updating to the most recent version of this product, service or offering (S35 Pinhole/Kit Camera to version 2025.08.28, S35 AI Fisheye \u0026 Dual Sensor/Micro Dome/Full Color Eyeball \u0026 Bullet Camera to version 2025.08.22, S35 Thermal Camera to version 2025.08.26)."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-22",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-22 Exploiting Trust in Client"
                }
              ]
            },
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-668",
                  "description": "CWE-668 Exposure of Resource to Wrong Sphere",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-27T15:03:57.602Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.honeywell.com/us/en/product-security"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Inadequate access control measure allows unauthorized users to access restricted administrative functions",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2025-12351",
        "datePublished": "2025-10-27T15:03:57.602Z",
        "dateReserved": "2025-10-27T14:59:57.822Z",
        "dateUpdated": "2025-10-27T16:04:11.466Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3947 (GCVE-0-2025-3947)

    Vulnerability from cvelistv5 – Published: 2025-07-10 20:19 – Updated: 2025-08-04 19:46
    VLAI
    Title
    Integer underflow during processing of short network packets in CDA FTEB responder
    Summary
    The Honeywell Experion PKS contains an Integer Underflow vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to Input Data Manipulation, which could result in improper integer data value checking during subtraction leading to a denial of service. Honeywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1. The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-191 - Integer Underflow (Wrap or Wraparound)
    Assigner
    References
    Impacted products
    Vendor Product Version
    Honeywell C300 PCNT02 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell C300 PCNT05 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell FIM4 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell FIM8 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell UOC Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell CN100 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell HCA Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell C300PM Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell C200E Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Credits
    Demid Uzenkov and Kirill Kutaev (Positive Technologies)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3947",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-10T20:34:52.670505Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-10T20:35:01.787Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C300 PCNT02",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C300 PCNT05",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "FIM4",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "FIM8",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "UOC",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "CN100",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "HCA",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C300PM",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C200E",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Demid Uzenkov and Kirill Kutaev (Positive Technologies)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The Honeywell Experion PKS contains an Integer Underflow \n\nvulnerability \n\nin the component Control\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eData Access (CDA). An attacker could potentially exploit this vulnerability, leading to \n\nInput Data Manipulation, which could result in improper\u0026nbsp;integer data value checking during subtraction leading to a denial of service.\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cbr\u003e\u003c/span\u003e\u003c/span\u003e\n\nHoneywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1.\u003cbr\u003e\u003cbr\u003eThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E.  The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.\n\n\u003cbr\u003e"
                }
              ],
              "value": "The Honeywell Experion PKS contains an Integer Underflow \n\nvulnerability \n\nin the component Control\u00a0Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to \n\nInput Data Manipulation, which could result in improper\u00a0integer data value checking during subtraction leading to a denial of service.\n\n\n\nHoneywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1.\n\nThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E.  The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-153",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-153 Input Data Manipulation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-191",
                  "description": "CWE-191 Integer Underflow (Wrap or Wraparound)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-04T19:46:31.982Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "url": "https://process.honeywell.com/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Integer underflow during processing of short network packets in CDA FTEB responder",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2025-3947",
        "datePublished": "2025-07-10T20:19:13.991Z",
        "dateReserved": "2025-04-25T15:21:22.614Z",
        "dateUpdated": "2025-08-04T19:46:31.982Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3946 (GCVE-0-2025-3946)

    Vulnerability from cvelistv5 – Published: 2025-07-10 20:16 – Updated: 2025-08-04 19:46
    VLAI
    Title
    Incorrect response generation during FTEB protocol processing
    Summary
    The Honeywell Experion PKS and OneWireless WDM contains a Deployment of Wrong Handler vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to Input Data Manipulation, which could result in incorrect handling of packets leading to remote code execution. Honeywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1. The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-430 - Deployment of Wrong Handler
    Assigner
    References
    Impacted products
    Vendor Product Version
    Honeywell C300 PCNT02 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell C300 PCNT05 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell FIM4 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell FIM8 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell UOC Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell CN100 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell HCA Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell C300PM Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell C200E Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell Wireless Device Manager Affected: 322.1 , ≤ 322.4 (semver)
    Affected: 330.1 , ≤ 330.3 (semver)
    Create a notification for this product.
    Credits
    Demid Uzenkov and Kirill Kutaev (Positive Technologies)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3946",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-10T20:35:19.798404Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-10T20:35:28.409Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C300 PCNT02",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C300 PCNT05",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "FIM4",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "FIM8",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "UOC",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "CN100",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "HCA",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C300PM",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C200E",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "OneWireless"
              ],
              "product": "Wireless Device Manager",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "322.4",
                  "status": "affected",
                  "version": "322.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "330.3",
                  "status": "affected",
                  "version": "330.1",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Demid Uzenkov and Kirill Kutaev (Positive Technologies)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The Honeywell Experion PKS \n\nand OneWireless WDM\n\ncontains a Deployment of Wrong Handler\n\n \n\nvulnerability \n\nin the component Control\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eData Access (CDA). An attacker could potentially exploit this vulnerability, leading to \n\nInput Data Manipulation, \n\n which could result in incorrect handling of packets leading to remote code execution.\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cbr\u003e\u003cbr\u003e\n\nHoneywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.\u003cbr\u003e\u003cbr\u003eThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E.  The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.\u003c/span\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.\n\n\u003cbr\u003e\u003c/span\u003e"
                }
              ],
              "value": "The Honeywell Experion PKS \n\nand OneWireless WDM\n\ncontains a Deployment of Wrong Handler\n\n \n\nvulnerability \n\nin the component Control\u00a0Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to \n\nInput Data Manipulation, \n\n which could result in incorrect handling of packets leading to remote code execution.\n\n\n\nHoneywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.\n\nThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E.  The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.\u00a0The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-153",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-153 Input Data Manipulation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-430",
                  "description": "CWE-430 Deployment of Wrong Handler",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-04T19:46:15.112Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "url": "https://process.honeywell.com/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Incorrect response generation during FTEB protocol processing",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2025-3946",
        "datePublished": "2025-07-10T20:16:54.743Z",
        "dateReserved": "2025-04-25T15:21:21.740Z",
        "dateUpdated": "2025-08-04T19:46:15.112Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-2523 (GCVE-0-2025-2523)

    Vulnerability from cvelistv5 – Published: 2025-07-10 20:15 – Updated: 2025-08-04 19:45
    VLAI
    Title
    Lack of buffer clearing before reuse may result in incorrect system behavior.
    Summary
    The Honeywell Experion PKS and OneWireless WDM contains an Integer Underflow vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in a failure during subtraction allowing remote code execution. Honeywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1. The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-191 - Integer Underflow (Wrap or Wraparound)
    Assigner
    References
    Impacted products
    Vendor Product Version
    Honeywell C300 PCNT02 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell C300 PCNT05 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell FIM4 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell FIM8 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell UOC Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell CN100 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell HCA Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell C300PM Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell C200E Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell Wireless Device Manager Affected: 322.1 , ≤ 322.4 (semver)
    Affected: 330.1 , ≤ 330.3 (semver)
    Create a notification for this product.
    Credits
    Demid Uzenkov and Kirill Kutaev (Positive Technologies)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-2523",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-10T20:35:45.591675Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-10T20:35:53.232Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C300 PCNT02",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C300 PCNT05",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "FIM4",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "FIM8",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "UOC",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "CN100",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "HCA",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C300PM",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C200E",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "OneWireless"
              ],
              "product": "Wireless Device Manager",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "322.4",
                  "status": "affected",
                  "version": "322.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "330.3",
                  "status": "affected",
                  "version": "330.1",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Demid Uzenkov and Kirill Kutaev (Positive Technologies)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The Honeywell Experion PKS \n\n and OneWireless WDM \n\ncontains an Integer Underflow \n\nvulnerability \n\nin the component Control\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eData Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in a failure\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;during subtraction allowing remote code execution.\u003c/span\u003e\u003c/span\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cbr\u003e\u003cbr\u003eHoneywell recommends updating to the most recent version of \n\nHoneywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.\u003cbr\u003e\u003c/span\u003e\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\nThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E.  The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.\n\n\u003c/span\u003e\u003cbr\u003e"
                }
              ],
              "value": "The Honeywell Experion PKS \n\n and OneWireless WDM \n\ncontains an Integer Underflow \n\nvulnerability \n\nin the component Control\u00a0Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in a failure\u00a0during subtraction allowing remote code execution.\n\n\n\nHoneywell recommends updating to the most recent version of \n\nHoneywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.\n\n\n\nThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E.  The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-216",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-216 Communication Channel Manipulation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-191",
                  "description": "CWE-191 Integer Underflow (Wrap or Wraparound)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-04T19:45:51.105Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "url": "https://process.honeywell.com/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Lack of buffer clearing before reuse may result in incorrect system behavior.",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2025-2523",
        "datePublished": "2025-07-10T20:15:32.600Z",
        "dateReserved": "2025-03-19T13:57:31.419Z",
        "dateUpdated": "2025-08-04T19:45:51.105Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-2522 (GCVE-0-2025-2522)

    Vulnerability from cvelistv5 – Published: 2025-07-10 20:11 – Updated: 2025-08-04 19:45
    VLAI
    Title
    Lack of buffer clearing before reuse may result in incorrect system behavior.
    Summary
    The Honeywell Experion PKS and OneWireless WDM contains Sensitive Information in Resource vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in buffer reuse which may cause incorrect system behavior. Honeywell also recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.  The affected Experion PKS products are C300, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are 520.1 before 520.2 TCU9 HF1 and 530 before 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-226 - Sensitive Information in Resource Not Removed Before Reuse
    Assigner
    References
    Impacted products
    Vendor Product Version
    Honeywell C300 PCNT02 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell C300 PCNT05 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell FIM4 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell FIM8 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell UOC Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell CN100 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell HCA Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell C300PM Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell C200E Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell Wireless Device Manager Affected: 322.1 , ≤ 322.4 (semver)
    Affected: 330.1 , ≤ 330.3 (semver)
    Create a notification for this product.
    Credits
    Demid Uzenkov and Kirill Kutaev (Positive Technologies)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-2522",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-10T20:34:00.516806Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-10T20:34:08.789Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C300 PCNT02",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C300 PCNT05",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "FIM4",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "FIM8",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "UOC",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "CN100",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "HCA",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C300PM",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C200E",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "OneWireless"
              ],
              "product": "Wireless Device Manager",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "322.4",
                  "status": "affected",
                  "version": "322.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "330.3",
                  "status": "affected",
                  "version": "330.1",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Demid Uzenkov and Kirill Kutaev (Positive Technologies)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The Honeywell Experion PKS\u0026nbsp;and OneWireless WDM \n\n contains Sensitive Information in Resource vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in buffer reuse which may cause incorrect system behavior.\n\n\u003cp\u003eHoneywell also recommends updating to the most recent version of \n\nHoneywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.\u0026nbsp;\u003c/p\u003e\u003cp\u003eThe affected Experion PKS products are \n\n\n\nC300, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E.  The Experion PKS versions affected are 520.1 before \n\n520.2 TCU9 HF1 and 530 before 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.\u003c/p\u003e"
                }
              ],
              "value": "The Honeywell Experion PKS\u00a0and OneWireless WDM \n\n contains Sensitive Information in Resource vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in buffer reuse which may cause incorrect system behavior.\n\nHoneywell also recommends updating to the most recent version of \n\nHoneywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.\u00a0\n\nThe affected Experion PKS products are \n\n\n\nC300, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E.  The Experion PKS versions affected are 520.1 before \n\n520.2 TCU9 HF1 and 530 before 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-216",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-216 Communication Channel Manipulation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-226",
                  "description": "CWE-226 Sensitive Information in Resource Not Removed Before Reuse",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-04T19:45:13.439Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "url": "https://process.honeywell.com/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Lack of buffer clearing before reuse may result in incorrect system behavior.",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2025-2522",
        "datePublished": "2025-07-10T20:11:43.603Z",
        "dateReserved": "2025-03-19T13:57:30.424Z",
        "dateUpdated": "2025-08-04T19:45:13.439Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-2521 (GCVE-0-2025-2521)

    Vulnerability from cvelistv5 – Published: 2025-07-10 20:08 – Updated: 2025-08-04 19:44
    VLAI
    Title
    Lack of indexes’ validation against buffer borders leads to remote code execution.
    Summary
    The Honeywell Experion PKS and OneWireless WDM contains a Memory Buffer vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to an Overread Buffers, which could result in improper index validation against buffer borders leading to remote code execution. Honeywell recommends updating to the most recent version of Honeywell Experion PKS: 520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1. The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
    Assigner
    References
    Impacted products
    Vendor Product Version
    Honeywell C300 PCNT02 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell C300 PCNT05 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell FIM4 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell FIM8 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell UOC Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell CN100 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell HCA Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell C300PM Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell C200E Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell Wireless Device Manager Affected: 322.1 , ≤ 322.4 (semver)
    Affected: 330.1 , ≤ 330.3 (semver)
    Create a notification for this product.
    Credits
    Demid Uzenkov and Kirill Kutaev (Positive Technologies)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-2521",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-10T20:33:41.946048Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-10T20:33:49.166Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C300 PCNT02",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C300 PCNT05",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "FIM4",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "FIM8",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "UOC",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "CN100",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "HCA",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C300PM",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C200E",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "OneWireless"
              ],
              "product": "Wireless Device Manager",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "322.4",
                  "status": "affected",
                  "version": "322.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "330.3",
                  "status": "affected",
                  "version": "330.1",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Demid Uzenkov and Kirill Kutaev (Positive Technologies)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe Honeywell Experion PKS and OneWireless WDM contains a Memory Buffer vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to an Overread Buffers, which could result in improper index validation against buffer borders leading to remote code execution.\u003c/p\u003e\u003cp\u003eHoneywell recommends updating to the most recent version of Honeywell Experion PKS:\n\n520.2 TCU9 HF1 and\u0026nbsp;530.1 TCU3 HF1 and OneWireless:\u0026nbsp;322.5 and 331.1.\u003c/p\u003e\u003cp\u003e\u003cbr\u003eThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E.  The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.\u003c/p\u003e"
                }
              ],
              "value": "The Honeywell Experion PKS and OneWireless WDM contains a Memory Buffer vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to an Overread Buffers, which could result in improper index validation against buffer borders leading to remote code execution.\n\nHoneywell recommends updating to the most recent version of Honeywell Experion PKS:\n\n520.2 TCU9 HF1 and\u00a0530.1 TCU3 HF1 and OneWireless:\u00a0322.5 and 331.1.\n\n\nThe affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E.  The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-540",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-540 Overread Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-04T19:44:27.744Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "url": "https://process.honeywell.com/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Lack of indexes\u2019 validation against buffer borders leads to remote code execution.",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2025-2521",
        "datePublished": "2025-07-10T20:08:04.077Z",
        "dateReserved": "2025-03-19T13:57:29.165Z",
        "dateUpdated": "2025-08-04T19:44:27.744Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-2520 (GCVE-0-2025-2520)

    Vulnerability from cvelistv5 – Published: 2025-07-10 19:54 – Updated: 2025-08-04 19:44
    VLAI
    Title
    Dereferencing of an uninitialized pointer leads to denial of service.
    Summary
    The Honeywell Experion PKS contains an Uninitialized Variable in the common Epic Platform Analyzer (EPA) communications. An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which results in a dereferencing of an uninitialized pointer leading to a denial of service. Honeywell recommends updating to the most recent version of Honeywell Experion PKS: 520.2 TCU9 HF1and 530.1 TCU3 HF1. The affected Experion PKS products are C300 PCNT02, EHB, EHPM, ELMM, Classic ENIM, ETN, FIM4, FIM8, PGM, and RFIM. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-457 - Use of Uninitialized Variable
    Assigner
    References
    Impacted products
    Vendor Product Version
    Honeywell C300 PCNT02 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell EHB Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell EHPM Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell ELMM Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell Classic ENIM Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell ETN Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell FIM4 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell FIM8 Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell PGM Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Honeywell RFIM Affected: 520.1 , ≤ 520.2 TCU9 (semver)
    Affected: 530 , ≤ 530 TCU3 (semver)
    Create a notification for this product.
    Credits
    Demid Uzenkov and Kirill Kutaev (Positive Technologies)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-2520",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-10T20:33:19.670618Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-10T20:33:30.482Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C300 PCNT02",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "EHB",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "EHPM",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "ELMM",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "Classic ENIM",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "ETN",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "FIM4",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "FIM8",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "PGM",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "RFIM",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU9",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "530 TCU3",
                  "status": "affected",
                  "version": "530",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Demid Uzenkov and Kirill Kutaev (Positive Technologies)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe Honeywell Experion PKS contains an \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUninitialized Variable i\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003en the common Epic Platform Analyzer (EPA) communications\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e. An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which results in a d\u003c/span\u003eereferencing of an uninitialized pointer leading to a denial of service.\u003cbr\u003e\u003cbr\u003e\n\nHoneywell recommends updating to the most recent version of \n\nHoneywell Experion PKS: 520.2 TCU9 HF1and\u0026nbsp;530.1 TCU3 HF1.\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe affected Experion PKS products are \n\nC300 PCNT02, EHB, EHPM, ELMM, Classic ENIM, ETN, FIM4, FIM8, PGM, and RFIM.  The Experion PKS versions affected are\u0026nbsp;from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.\u003c/span\u003e\u003cbr\u003e"
                }
              ],
              "value": "The Honeywell Experion PKS contains an Uninitialized Variable in the common Epic Platform Analyzer (EPA) communications. An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which results in a dereferencing of an uninitialized pointer leading to a denial of service.\n\n\n\nHoneywell recommends updating to the most recent version of \n\nHoneywell Experion PKS: 520.2 TCU9 HF1and\u00a0530.1 TCU3 HF1.\u00a0The affected Experion PKS products are \n\nC300 PCNT02, EHB, EHPM, ELMM, Classic ENIM, ETN, FIM4, FIM8, PGM, and RFIM.  The Experion PKS versions affected are\u00a0from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-216",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-216 Communication Channel Manipulation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-457",
                  "description": "CWE-457 Use of Uninitialized Variable",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-04T19:44:48.506Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "url": "https://process.honeywell.com/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Dereferencing of an uninitialized pointer leads to denial of service.",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2025-2520",
        "datePublished": "2025-07-10T19:54:35.250Z",
        "dateReserved": "2025-03-19T13:57:27.868Z",
        "dateUpdated": "2025-08-04T19:44:48.506Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-2605 (GCVE-0-2025-2605)

    Vulnerability from cvelistv5 – Published: 2025-05-02 12:39 – Updated: 2025-05-17 06:03
    VLAI
    Title
    Authenticated command injection
    Summary
    Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    Honeywell MB-Secure Affected: V11.04 , < V12.53 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-2605",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-02T13:32:21.228869Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-02T13:32:33.807Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-05-17T06:03:36.347Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2025/May/19"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "MB-Secure",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThan": "V12.53",
                  "status": "affected",
                  "version": "V11.04",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product."
                }
              ],
              "value": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-122",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-122 Privilege Abuse"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-02T12:39:39.979Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.honeywell.com/us/en/product-security#security-notices"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Authenticated command injection",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2025-2605",
        "datePublished": "2025-05-02T12:39:39.979Z",
        "dateReserved": "2025-03-21T13:18:29.509Z",
        "dateUpdated": "2025-05-17T06:03:36.347Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-5878 (GCVE-0-2023-5878)

    Vulnerability from cvelistv5 – Published: 2025-02-06 14:10 – Updated: 2025-02-18 18:13
    VLAI
    Title
    OneWireless command injection possible when updating firmware
    Summary
    Honeywell OneWireless Wireless Device Manager (WDM) for the following versions R310.x, R320.x, R321.x, R322.1, R322.2, R323.x, R330.1 contains a command injection vulnerability. An attacker who is authenticated could use the firmware update process to potentially exploit the vulnerability, leading to a command injection. Honeywell recommends updating to R322.3, R330.2 or the most recent version of this product2.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Honeywell OneWireless Network Wireless Device Manager Affected: 310.1 , ≤ 322.2 (semver)
    Affected: 323.1 , ≤ 330.1 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-5878",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-06T14:26:15.468750Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-18T18:13:44.990Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Linux"
              ],
              "product": "OneWireless Network Wireless Device Manager",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "322.2",
                  "status": "affected",
                  "version": "310.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "330.1",
                  "status": "affected",
                  "version": "323.1",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eHoneywell OneWireless \n\nWireless Device Manager (WDM)\u0026nbsp;for the following versions R310.x, R320.x, R321.x, R322.1, R322.2, R323.x, R330.1 contains a command injection vulnerability. An attacker who is authenticated could use the firmware update process to potentially exploit the vulnerability, leading to a command injection. Honeywell recommends updating to \n\n R322.3, R330.2 or the most recent version of this product2.\n\n\u003c/span\u003e\u003cbr\u003e"
                }
              ],
              "value": "Honeywell OneWireless \n\nWireless Device Manager (WDM)\u00a0for the following versions R310.x, R320.x, R321.x, R322.1, R322.2, R323.x, R330.1 contains a command injection vulnerability. An attacker who is authenticated could use the firmware update process to potentially exploit the vulnerability, leading to a command injection. Honeywell recommends updating to \n\n R322.3, R330.2 or the most recent version of this product2."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-248",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-248 Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-02-06T14:10:30.295Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "url": "https://process.honeywell.com/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "OneWireless command injection possible when updating firmware",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2023-5878",
        "datePublished": "2025-02-06T14:10:30.295Z",
        "dateReserved": "2023-10-31T13:16:00.514Z",
        "dateUpdated": "2025-02-18T18:13:44.990Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-6620 (GCVE-0-2024-6620)

    Vulnerability from cvelistv5 – Published: 2024-07-29 20:14 – Updated: 2024-08-01 21:41
    VLAI
    Summary
    Honeywell PC42t, PC42tp, and PC42d Printers, T10.19.020016 to T10.20.060398, contain a cross-site scripting vulnerability. A(n) attacker could potentially inject malicious code which may lead to information disclosure, session theft, or client-side request forgery. Honeywell recommends updating to the most recent version of this firmware, PC42 Printer Firmware Version 20.6 T10.20.060398.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    Assigner
    References
    Impacted products
    Vendor Product Version
    Honeywell PC42t, PC42tp, and PC42d (Common Firmware) Affected: T10.19.020016 , < T10.20.060398 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-6620",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-30T14:17:52.818483Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-30T14:17:59.561Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T21:41:03.974Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://sps.honeywell.com/us/en/support/productivity/cyber-security-notifications"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PC42t, PC42tp, and PC42d (Common Firmware)",
              "vendor": "Honeywell",
              "versions": [
                {
                  "changes": [
                    {
                      "at": "T10.20.060398",
                      "status": "unaffected"
                    }
                  ],
                  "lessThan": "T10.20.060398",
                  "status": "affected",
                  "version": "T10.19.020016",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Honeywell PC42t, PC42tp, and PC42d Printers, T10.19.020016 to T10.20.060398, contain a cross-site scripting vulnerability. A(n) attacker could potentially inject malicious code which may lead to information disclosure, session theft, or client-side request forgery. Honeywell recommends updating to the most recent version of this firmware, PC42 Printer Firmware Version 20.6 T10.20.060398."
                }
              ],
              "value": "Honeywell PC42t, PC42tp, and PC42d Printers, T10.19.020016 to T10.20.060398, contain a cross-site scripting vulnerability. A(n) attacker could potentially inject malicious code which may lead to information disclosure, session theft, or client-side request forgery. Honeywell recommends updating to the most recent version of this firmware, PC42 Printer Firmware Version 20.6 T10.20.060398."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-63",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-63 Cross-Site Scripting (XSS)"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 3.5,
                "baseSeverity": "LOW",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-602",
                  "description": "CWE-602",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-29T20:14:27.666Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://sps.honeywell.com/us/en/support/productivity/cyber-security-notifications"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2024-6620",
        "datePublished": "2024-07-29T20:14:27.666Z",
        "dateReserved": "2024-07-09T15:50:58.050Z",
        "dateUpdated": "2024-08-01T21:41:03.974Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-2422 (GCVE-0-2024-2422)

    Vulnerability from cvelistv5 – Published: 2024-05-30 17:26 – Updated: 2024-08-01 19:11
    VLAI
    Title
    LenelS2 NetBox Improper Neutralization of Argumented Delimiters
    Summary
    LenelS2 NetBox access control and event monitoring system was discovered to contain an authenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-88 - Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    LenelS2 NetBox Affected: All , ≤ 5.6.1 (custom)
    Create a notification for this product.
    carrier lenels2_netbox Affected: 0 , ≤ 5.6.1 (custom)
        cpe:2.3:a:carrier:lenels2_netbox:0:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Claroty Team82
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:carrier:lenels2_netbox:0:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "lenels2_netbox",
                "vendor": "carrier",
                "versions": [
                  {
                    "lessThanOrEqual": "5.6.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-2422",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-30T23:15:27.680824Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T17:30:36.769Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T19:11:53.469Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.corporate.carrier.com/Images/CARR-PSA-2024-01-NetBox_tcm558-227956.pdf"
              },
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "NetBox",
              "vendor": "LenelS2",
              "versions": [
                {
                  "lessThanOrEqual": "5.6.1",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Claroty Team82"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "LenelS2 NetBox access control and event monitoring system was discovered to contain an authenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands."
                }
              ],
              "value": "LenelS2 NetBox access control and event monitoring system was discovered to contain an authenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-88",
                  "description": "CWE-88 Improper Neutralization of Argument Delimiters in a Command (\u0027Argument Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-30T17:26:12.543Z",
            "orgId": "e24e6442-3ae1-4538-a7b8-7ac95586db8f",
            "shortName": "Carrier"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.corporate.carrier.com/Images/CARR-PSA-2024-01-NetBox_tcm558-227956.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "LenelS2 advises customers to apply to the updated version of NetBox 5.6.2 or newer via the LenelS2 Partner Center. Please get in touch with your support channel partner for instructions."
                }
              ],
              "value": "LenelS2 advises customers to apply to the updated version of NetBox 5.6.2 or newer via the LenelS2 Partner Center. Please get in touch with your support channel partner for instructions."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "LenelS2 NetBox Improper Neutralization of Argumented Delimiters",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e24e6442-3ae1-4538-a7b8-7ac95586db8f",
        "assignerShortName": "Carrier",
        "cveId": "CVE-2024-2422",
        "datePublished": "2024-05-30T17:26:12.543Z",
        "dateReserved": "2024-03-13T13:55:55.979Z",
        "dateUpdated": "2024-08-01T19:11:53.469Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-2421 (GCVE-0-2024-2421)

    Vulnerability from cvelistv5 – Published: 2024-05-30 17:24 – Updated: 2024-08-01 19:11
    VLAI
    Title
    LenelS2 NetBox Improper Neutralization of Special Elements
    Summary
    LenelS2 NetBox access control and event monitoring system was discovered to contain an unauthenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands with elevated permissions.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    LenelS2 NetBox Affected: All , ≤ 5.6.1 (custom)
    Create a notification for this product.
    carrier lenels2_netbox Affected: 0 , ≤ 5.6.1 (custom)
        cpe:2.3:a:carrier:lenels2_netbox:0:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Claroty Team82
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:carrier:lenels2_netbox:0:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "lenels2_netbox",
                "vendor": "carrier",
                "versions": [
                  {
                    "lessThanOrEqual": "5.6.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-2421",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-31T16:38:35.581709Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T17:29:16.378Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T19:11:53.525Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.corporate.carrier.com/Images/CARR-PSA-2024-01-NetBox_tcm558-227956.pdf"
              },
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "NetBox",
              "vendor": "LenelS2",
              "versions": [
                {
                  "lessThanOrEqual": "5.6.1",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Claroty Team82"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "LenelS2 NetBox access control and event monitoring system was discovered to contain an unauthenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands with elevated permissions."
                }
              ],
              "value": "LenelS2 NetBox access control and event monitoring system was discovered to contain an unauthenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands with elevated permissions."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-30T17:24:33.231Z",
            "orgId": "e24e6442-3ae1-4538-a7b8-7ac95586db8f",
            "shortName": "Carrier"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.corporate.carrier.com/Images/CARR-PSA-2024-01-NetBox_tcm558-227956.pdf"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "LenelS2 advises customers to apply to the updated version of NetBox 5.6.2 or newer via the LenelS2 Partner Center. Please get in touch with your support channel partner for instructions."
                }
              ],
              "value": "LenelS2 advises customers to apply to the updated version of NetBox 5.6.2 or newer via the LenelS2 Partner Center. Please get in touch with your support channel partner for instructions."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "LenelS2 NetBox Improper Neutralization of Special Elements",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e24e6442-3ae1-4538-a7b8-7ac95586db8f",
        "assignerShortName": "Carrier",
        "cveId": "CVE-2024-2421",
        "datePublished": "2024-05-30T17:24:33.231Z",
        "dateReserved": "2024-03-13T13:55:51.729Z",
        "dateUpdated": "2024-08-01T19:11:53.525Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-2420 (GCVE-0-2024-2420)

    Vulnerability from cvelistv5 – Published: 2024-05-30 17:22 – Updated: 2024-08-01 19:11
    VLAI
    Title
    LenelS2 NetBox Hardcoded Credentials
    Summary
    LenelS2 NetBox access control and event monitoring system was discovered to contain Hardcoded Credentials in versions prior to and including 5.6.1 which allows an attacker to bypass authentication requirements.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-259 - Use of Hardcoded Password
    Assigner
    Impacted products
    Vendor Product Version
    LenelS2 NetBox Affected: All , ≤ 5.6.1 (custom)
    Create a notification for this product.
    carrier lenels2_netbox Affected: 0 , ≤ 5.6.1 (custom)
        cpe:2.3:a:carrier:lenels2_netbox:0:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Claroty Team82
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:carrier:lenels2_netbox:0:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "lenels2_netbox",
                "vendor": "carrier",
                "versions": [
                  {
                    "lessThanOrEqual": "5.6.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-2420",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-30T19:12:38.190957Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T17:29:12.413Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T19:11:53.496Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.corporate.carrier.com/Images/CARR-PSA-2024-01-NetBox_tcm558-227956.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "NetBox",
              "vendor": "LenelS2",
              "versions": [
                {
                  "lessThanOrEqual": "5.6.1",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Claroty Team82"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "LenelS2 NetBox access control and event monitoring system was discovered to contain\u0026nbsp;Hardcoded Credentials in versions prior to and including 5.6.1 which allows an attacker to bypass authentication requirements.\u0026nbsp;"
                }
              ],
              "value": "LenelS2 NetBox access control and event monitoring system was discovered to contain\u00a0Hardcoded Credentials in versions prior to and including 5.6.1 which allows an attacker to bypass authentication requirements."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-259",
                  "description": "CWE-259 Use of Hardcoded Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-30T17:22:06.344Z",
            "orgId": "e24e6442-3ae1-4538-a7b8-7ac95586db8f",
            "shortName": "Carrier"
          },
          "references": [
            {
              "url": "https://www.corporate.carrier.com/Images/CARR-PSA-2024-01-NetBox_tcm558-227956.pdf"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "LenelS2 advises customers to apply to the updated version of NetBox 5.6.2 or newer via the LenelS2 Partner Center. Please get in touch with your support channel partner for instructions."
                }
              ],
              "value": "LenelS2 advises customers to apply to the updated version of NetBox 5.6.2 or newer via the LenelS2 Partner Center. Please get in touch with your support channel partner for instructions."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "LenelS2 NetBox Hardcoded Credentials",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e24e6442-3ae1-4538-a7b8-7ac95586db8f",
        "assignerShortName": "Carrier",
        "cveId": "CVE-2024-2420",
        "datePublished": "2024-05-30T17:22:06.344Z",
        "dateReserved": "2024-03-13T13:55:47.727Z",
        "dateUpdated": "2024-08-01T19:11:53.496Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-51605 (GCVE-0-2023-51605)

    Vulnerability from cvelistv5 – Published: 2024-05-03 02:15 – Updated: 2024-09-18 18:30
    VLAI
    Title
    Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability
    Summary
    Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18644.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-611 - Improper Restriction of XML External Entity Reference ('XXE')
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Honeywell Saia PG5 Controls Suite Affected: PG5 v2.3.193
    Create a notification for this product.
    honeywell saia_pg5_controls_suite Affected: *
        cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2023-12-20 22:49
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "saia_pg5_controls_suite",
                "vendor": "honeywell",
                "versions": [
                  {
                    "status": "affected",
                    "version": "*"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-51605",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-03T18:36:03.220078Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T17:20:39.707Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:40:33.664Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "ZDI-23-1854",
                "tags": [
                  "x_research-advisory",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1854/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Saia PG5 Controls Suite",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "PG5 v2.3.193"
                }
              ]
            }
          ],
          "dateAssigned": "2023-12-20T22:02:27.276Z",
          "datePublic": "2023-12-20T22:49:48.039Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process.\n. Was ZDI-CAN-18644."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611: Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-09-18T18:30:48.470Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-23-1854",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1854/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "kimiya"
          },
          "title": "Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2023-51605",
        "datePublished": "2024-05-03T02:15:31.381Z",
        "dateReserved": "2023-12-20T21:52:34.956Z",
        "dateUpdated": "2024-09-18T18:30:48.470Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-51604 (GCVE-0-2023-51604)

    Vulnerability from cvelistv5 – Published: 2024-05-03 02:15 – Updated: 2024-09-18 18:30
    VLAI
    Title
    Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability
    Summary
    Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18593.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-611 - Improper Restriction of XML External Entity Reference ('XXE')
    Assigner
    zdi
    References
    Impacted products
    Date Public
    2023-12-20 22:49
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-51604",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-01T14:34:56.786244Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-05T17:22:56.741Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:40:34.051Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "ZDI-23-1853",
                "tags": [
                  "x_research-advisory",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1853/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Saia PG5 Controls Suite",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "PG5 v2.3.193"
                }
              ]
            }
          ],
          "dateAssigned": "2023-12-20T22:02:27.270Z",
          "datePublic": "2023-12-20T22:49:44.908Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process.\n. Was ZDI-CAN-18593."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611: Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-09-18T18:30:47.737Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-23-1853",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1853/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "kimiya"
          },
          "title": "Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2023-51604",
        "datePublished": "2024-05-03T02:15:30.665Z",
        "dateReserved": "2023-12-20T21:52:34.956Z",
        "dateUpdated": "2024-09-18T18:30:47.737Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-51603 (GCVE-0-2023-51603)

    Vulnerability from cvelistv5 – Published: 2024-05-03 02:15 – Updated: 2024-09-18 18:30
    VLAI
    Title
    Honeywell Saia PG5 Controls Suite CAB File Parsing Directory Traversal Remote Code Execution Vulnerability
    Summary
    Honeywell Saia PG5 Controls Suite CAB File Parsing Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of CAB files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user. . Was ZDI-CAN-18592.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Honeywell Saia PG5 Controls Suite Affected: PG5 v2.3.193
    Create a notification for this product.
    honeywell saia_pg5_controls_suite Affected: R.47.0.0 AutoCAD 2021
    Affected: R.47.0.0 AutoCAD LT 2021
        cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2023-12-20 22:49
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "saia_pg5_controls_suite",
                "vendor": "honeywell",
                "versions": [
                  {
                    "status": "affected",
                    "version": "R.47.0.0 AutoCAD 2021"
                  },
                  {
                    "status": "affected",
                    "version": "R.47.0.0 AutoCAD LT 2021"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-51603",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-17T19:54:57.501218Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-17T19:57:06.437Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:40:33.746Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "ZDI-23-1852",
                "tags": [
                  "x_research-advisory",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1852/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Saia PG5 Controls Suite",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "PG5 v2.3.193"
                }
              ]
            }
          ],
          "dateAssigned": "2023-12-20T22:02:27.264Z",
          "datePublic": "2023-12-20T22:49:40.978Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Honeywell Saia PG5 Controls Suite CAB File Parsing Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of CAB files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user.\n. Was ZDI-CAN-18592."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-09-18T18:30:47.006Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-23-1852",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1852/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "kimiya"
          },
          "title": "Honeywell Saia PG5 Controls Suite CAB File Parsing Directory Traversal Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2023-51603",
        "datePublished": "2024-05-03T02:15:29.933Z",
        "dateReserved": "2023-12-20T21:52:34.955Z",
        "dateUpdated": "2024-09-18T18:30:47.006Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-51602 (GCVE-0-2023-51602)

    Vulnerability from cvelistv5 – Published: 2024-05-03 02:15 – Updated: 2024-09-18 18:30
    VLAI
    Title
    Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability
    Summary
    Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18591.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-611 - Improper Restriction of XML External Entity Reference ('XXE')
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Honeywell Saia PG5 Controls Suite Affected: PG5 v2.3.193
    Create a notification for this product.
    honeywell saia_pg5_controls_suite Affected: *
        cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2023-12-20 22:49
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "saia_pg5_controls_suite",
                "vendor": "honeywell",
                "versions": [
                  {
                    "status": "affected",
                    "version": "*"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-51602",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-03T18:38:50.340421Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T17:21:01.406Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:40:33.823Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "ZDI-23-1851",
                "tags": [
                  "x_research-advisory",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1851/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Saia PG5 Controls Suite",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "PG5 v2.3.193"
                }
              ]
            }
          ],
          "dateAssigned": "2023-12-20T22:02:27.255Z",
          "datePublic": "2023-12-20T22:49:37.696Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process.\n. Was ZDI-CAN-18591."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611: Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-09-18T18:30:46.275Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-23-1851",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1851/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "kimiya"
          },
          "title": "Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2023-51602",
        "datePublished": "2024-05-03T02:15:29.225Z",
        "dateReserved": "2023-12-20T21:52:34.955Z",
        "dateUpdated": "2024-09-18T18:30:46.275Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-51601 (GCVE-0-2023-51601)

    Vulnerability from cvelistv5 – Published: 2024-05-03 02:15 – Updated: 2024-09-18 18:30
    VLAI
    Title
    Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability
    Summary
    Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of xml files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18563.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-611 - Improper Restriction of XML External Entity Reference ('XXE')
    Assigner
    zdi
    References
    Impacted products
    Date Public
    2023-12-20 22:49
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-51601",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-06T20:56:28.606294Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T17:20:13.625Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:40:34.078Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "ZDI-23-1850",
                "tags": [
                  "x_research-advisory",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1850/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Saia PG5 Controls Suite",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "PG5 v2.3.193"
                }
              ]
            }
          ],
          "dateAssigned": "2023-12-20T22:02:27.249Z",
          "datePublic": "2023-12-20T22:49:33.599Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of xml files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process.\n. Was ZDI-CAN-18563."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611: Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-09-18T18:30:45.526Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-23-1850",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1850/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "kimiya"
          },
          "title": "Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2023-51601",
        "datePublished": "2024-05-03T02:15:28.512Z",
        "dateReserved": "2023-12-20T21:52:34.955Z",
        "dateUpdated": "2024-09-18T18:30:45.526Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-51600 (GCVE-0-2023-51600)

    Vulnerability from cvelistv5 – Published: 2024-05-03 02:15 – Updated: 2024-09-18 18:30
    VLAI
    Title
    Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability
    Summary
    Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18456.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-611 - Improper Restriction of XML External Entity Reference ('XXE')
    Assigner
    zdi
    References
    Impacted products
    Date Public
    2023-12-20 22:49
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-51600",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-03T14:30:44.991300Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T17:20:21.664Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:40:34.079Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "ZDI-23-1849",
                "tags": [
                  "x_research-advisory",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1849/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Saia PG5 Controls Suite",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "PG5 v2.3.193"
                }
              ]
            }
          ],
          "dateAssigned": "2023-12-20T22:02:27.242Z",
          "datePublic": "2023-12-20T22:49:30.422Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process.\n. Was ZDI-CAN-18456."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611: Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-09-18T18:30:44.834Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-23-1849",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1849/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "kimiya"
          },
          "title": "Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2023-51600",
        "datePublished": "2024-05-03T02:15:27.803Z",
        "dateReserved": "2023-12-20T21:52:34.954Z",
        "dateUpdated": "2024-09-18T18:30:44.834Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-51599 (GCVE-0-2023-51599)

    Vulnerability from cvelistv5 – Published: 2024-05-03 02:15 – Updated: 2024-09-18 18:30
    VLAI
    Title
    Honeywell Saia PG5 Controls Suite Directory Traversal Remote Code Execution Vulnerability
    Summary
    Honeywell Saia PG5 Controls Suite Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of ZIP files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user. . Was ZDI-CAN-18412.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Honeywell Saia PG5 Controls Suite Affected: PG5 v2.3.193
    Create a notification for this product.
    honeywell saia_pg5_controls_suite Affected: r.47.0.0
        cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2023-12-20 22:49
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "saia_pg5_controls_suite",
                "vendor": "honeywell",
                "versions": [
                  {
                    "status": "affected",
                    "version": "r.47.0.0"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-51599",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-18T14:49:59.233158Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-18T14:57:00.869Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:40:33.795Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "ZDI-23-1848",
                "tags": [
                  "x_research-advisory",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1848/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Saia PG5 Controls Suite",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "PG5 v2.3.193"
                }
              ]
            }
          ],
          "dateAssigned": "2023-12-20T22:02:27.233Z",
          "datePublic": "2023-12-20T22:49:25.983Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Honeywell Saia PG5 Controls Suite Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of ZIP files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user.\n. Was ZDI-CAN-18412."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-09-18T18:30:44.132Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-23-1848",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1848/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "kimiya"
          },
          "title": "Honeywell Saia PG5 Controls Suite Directory Traversal Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2023-51599",
        "datePublished": "2024-05-03T02:15:27.023Z",
        "dateReserved": "2023-12-20T21:52:34.954Z",
        "dateUpdated": "2024-09-18T18:30:44.132Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-5407 (GCVE-0-2023-5407)

    Vulnerability from cvelistv5 – Published: 2024-04-17 16:49 – Updated: 2024-08-08 15:49
    VLAI
    Summary
    Controller denial of service due to improper handling of a specially crafted message received by the controller. See Honeywell Security Notification for recommendations on upgrading and versioning.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Honeywell C300 Affected: 520.2 , ≤ 520.2 TCU4 (semver)
    Affected: 510.1 , ≤ 510.2 HF13 (semver)
    Affected: 520.1 , ≤ 520.1 TCU4 (semver)
    Affected: 511.1 , ≤ 511.5 TCU4 HF3 (semver)
    Create a notification for this product.
    Honeywell C300 Affected: 520.2 , ≤ 520.2 TCU4 (semver)
    Affected: 511.1 , ≤ 511.5 TCU4 HF3 (semver)
    Affected: 520.1 , ≤ 520.1 TCU4 (semver)
    Create a notification for this product.
    Honeywell C300 Affected: 520.2 , ≤ 520.2 TCU4 (semver)
    Affected: 520.1 , ≤ 520.1 TCU4 (semver)
    Affected: 520.2 TCU4 HFR2 , ≤ 511.5 TCU4 HF3 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T07:59:44.482Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://process.honeywell.com"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-5407",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-04-24T14:30:38.880683Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-08T15:49:07.567Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "C300",
              "vendor": "Honeywell",
              "versions": [
                {
                  "changes": [
                    {
                      "at": "520.2 TCU4 HF1",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.2 TCU4",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "510.2 HF14",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "510.2 HF13",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "520.1 TCU5",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.1 TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "511.5 TCU4 HF4",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "511.5 TCU4 HF3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion LX"
              ],
              "product": "C300",
              "vendor": "Honeywell",
              "versions": [
                {
                  "changes": [
                    {
                      "at": "520.2 TCU4 HF2",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.2 TCU4",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "511.5 TCU4 HF4",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "511.5 TCU4 HF3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "520.1 TCU5",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.1 TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "PlantCruise by Experion"
              ],
              "product": "C300",
              "vendor": "Honeywell",
              "versions": [
                {
                  "changes": [
                    {
                      "at": "520.2 TCU4 HF2",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.2 TCU4",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "520.1 TCU5",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.1 TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "511.5 TCU4 HF4",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "511.5 TCU4 HF3",
                  "status": "affected",
                  "version": "520.2 TCU4 HFR2",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Controller denial of service due to improper handling of a specially crafted message received by the controller.\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSee Honeywell Security Notification for recommendations on upgrading and versioning.\u003c/span\u003e"
                }
              ],
              "value": "Controller denial of service due to improper handling of a specially crafted message received by the controller.\n\nSee Honeywell Security Notification for recommendations on upgrading and versioning."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-09T19:38:30.357Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "url": "https://process.honeywell.com"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2023-5407",
        "datePublished": "2024-04-17T16:49:16.900Z",
        "dateReserved": "2023-10-04T17:50:55.299Z",
        "dateUpdated": "2024-08-08T15:49:07.567Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-5406 (GCVE-0-2023-5406)

    Vulnerability from cvelistv5 – Published: 2024-04-17 16:47 – Updated: 2024-08-02 07:59
    VLAI
    Summary
    Server communication with a controller can lead to remote code execution using a specially crafted message from the controller. See Honeywell Security Notification for recommendations on upgrading and versioning.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Honeywell Experion Server Affected: 520.2 , ≤ 520.2 TCU4 (semver)
    Affected: 510.1 , ≤ 510.2 HF13 (semver)
    Affected: 520.1 , ≤ 520.1 TCU4 (semver)
    Affected: 511.1 , ≤ 511.5 TCU4 HF3 (semver)
    Create a notification for this product.
    Honeywell Experion Server Affected: 520.2 , ≤ 520.2 TCU4 (semver)
    Affected: 511.1 , ≤ 511.5 TCU4 HF3 (semver)
    Affected: 520.1 , ≤ 520.1 TCU4 (semver)
    Create a notification for this product.
    Honeywell Experion Server Affected: 520.2 , ≤ 520.2 TCU4 (semver)
    Affected: 520.1 , ≤ 520.1 TCU4 (semver)
    Affected: 520.2 TCU4 HFR2 , ≤ 511.5 TCU4 HF3 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-5406",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-31T14:00:17.610687Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-31T14:00:27.382Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T07:59:44.668Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://process.honeywell.com"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "Experion Server",
              "vendor": "Honeywell",
              "versions": [
                {
                  "changes": [
                    {
                      "at": "520.2 TCU4 HF1",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.2 TCU4",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "510.2 HF14",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "510.2 HF13",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "520.1 TCU5",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.1 TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "511.5 TCU4 HF4",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "511.5 TCU4 HF3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion LX"
              ],
              "product": "Experion Server",
              "vendor": "Honeywell",
              "versions": [
                {
                  "changes": [
                    {
                      "at": "520.2 TCU4 HF2",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.2 TCU4",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "511.5 TCU4 HF4",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "511.5 TCU4 HF3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "520.1 TCU5",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.1 TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "PlantCruise by Experion"
              ],
              "product": "Experion Server",
              "vendor": "Honeywell",
              "versions": [
                {
                  "changes": [
                    {
                      "at": "520.2 TCU4 HF2",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.2 TCU4",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "520.1 TCU5",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.1 TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "511.5 TCU4 HF4",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "511.5 TCU4 HF3",
                  "status": "affected",
                  "version": "520.2 TCU4 HFR2",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Server communication with a controller can lead to remote code execution using a specially crafted message from the controller.\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSee Honeywell Security Notification for recommendations on upgrading and versioning.\u003c/span\u003e"
                }
              ],
              "value": "Server communication with a controller can lead to remote code execution using a specially crafted message from the controller.\u00a0See Honeywell Security Notification for recommendations on upgrading and versioning."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-09T19:39:39.707Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "url": "https://process.honeywell.com"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2023-5406",
        "datePublished": "2024-04-17T16:47:50.336Z",
        "dateReserved": "2023-10-04T17:50:54.642Z",
        "dateUpdated": "2024-08-02T07:59:44.668Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-5405 (GCVE-0-2023-5405)

    Vulnerability from cvelistv5 – Published: 2024-04-17 16:46 – Updated: 2025-02-06 16:54
    VLAI
    Summary
    Server information leak for the CDA Server process memory can occur when an error is generated in response to a specially crafted message. See Honeywell Security Notification for recommendations on upgrading and versioning.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Honeywell Experion Server Affected: 520.2 , ≤ 520.2 TCU4 (semver)
    Affected: 510.1 , ≤ 510.2 HF13 (semver)
    Affected: 520.1 , ≤ 520.1 TCU4 (semver)
    Affected: 511.1 , ≤ 511.5 TCU4 HF3 (semver)
    Create a notification for this product.
    Honeywell Experion Server Affected: 520.2 , ≤ 520.2 TCU4 (semver)
    Affected: 511.1 , ≤ 511.5 TCU4 HF3 (semver)
    Affected: 520.1 , ≤ 520.1 TCU4 (semver)
    Create a notification for this product.
    Honeywell Experion Server Affected: 520.2 , ≤ 520.2 TCU4 (semver)
    Affected: 520.1 , ≤ 520.1 TCU4 (semver)
    Affected: 520.2 TCU4 HFR2 , ≤ 511.5 TCU4 HF3 (semver)
    Create a notification for this product.
    honeywell experion_server Unaffected: 510.1
        cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "experion_server",
                "vendor": "honeywell",
                "versions": [
                  {
                    "status": "unaffected",
                    "version": "510.1"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 5.9,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-5405",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-04-23T19:50:22.844378Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-787",
                    "description": "CWE-787",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-06T16:54:27.235Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T07:59:44.586Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://process.honeywell.com"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "Experion Server",
              "vendor": "Honeywell",
              "versions": [
                {
                  "changes": [
                    {
                      "at": "520.2 TCU4 HF1",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.2 TCU4",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "510.2 HF14",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "510.2 HF13",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "520.1 TCU5",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.1 TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "511.5 TCU4 HF4",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "511.5 TCU4 HF3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion LX"
              ],
              "product": "Experion Server",
              "vendor": "Honeywell",
              "versions": [
                {
                  "changes": [
                    {
                      "at": "520.2 TCU4 HF2",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.2 TCU4",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "511.5 TCU4 HF4",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "511.5 TCU4 HF3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "520.1 TCU5",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.1 TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "PlantCruise by Experion"
              ],
              "product": "Experion Server",
              "vendor": "Honeywell",
              "versions": [
                {
                  "changes": [
                    {
                      "at": "520.2 TCU4 HF2",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.2 TCU4",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "520.1 TCU5",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.1 TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "511.5 TCU4 HF4",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "511.5 TCU4 HF3",
                  "status": "affected",
                  "version": "520.2 TCU4 HFR2",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Server information leak for the CDA Server process memory can occur when an error is generated in response to a specially crafted message.\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSee Honeywell Security Notification for recommendations on upgrading and versioning.\u003c/span\u003e"
                }
              ],
              "value": "Server information leak for the CDA Server process memory can occur when an error is generated in response to a specially crafted message.\u00a0See Honeywell Security Notification for recommendations on upgrading and versioning."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-09T19:53:16.536Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "url": "https://process.honeywell.com"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2023-5405",
        "datePublished": "2024-04-17T16:46:29.950Z",
        "dateReserved": "2023-10-04T17:50:54.177Z",
        "dateUpdated": "2025-02-06T16:54:27.235Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-5404 (GCVE-0-2023-5404)

    Vulnerability from cvelistv5 – Published: 2024-04-17 16:44 – Updated: 2024-08-02 07:59
    VLAI
    Summary
    Server receiving a malformed message can cause a pointer to be overwritten which can result in a remote code execution or failure. See Honeywell Security Notification for recommendations on upgrading and versioning.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Honeywell Experion Server Affected: 520.2 , ≤ 520.2 TCU4 (semver)
    Affected: 510.1 , ≤ 510.2 HF13 (semver)
    Affected: 520.1 , ≤ 520.1 TCU4 (semver)
    Affected: 511.1 , ≤ 511.5 TCU4 HF3 (semver)
    Create a notification for this product.
    Honeywell Experion Server Affected: 520.2 , ≤ 520.2 TCU4 (semver)
    Affected: 511.1 , ≤ 511.5 TCU4 HF3 (semver)
    Affected: 520.1 , ≤ 520.1 TCU4 (semver)
    Create a notification for this product.
    Honeywell Experion Server Affected: 520.2 , ≤ 520.2 TCU4 (semver)
    Affected: 520.1 , ≤ 520.1 TCU4 (semver)
    Affected: 520.2 TCU4 HFR2 , ≤ 511.5 TCU4 HF3 (semver)
    Create a notification for this product.
    honeywell experion_server Affected: 520.2, 510.1, 520.1, 511.1, 520.2, 511.1
        cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "experion_server",
                "vendor": "honeywell",
                "versions": [
                  {
                    "status": "affected",
                    "version": "520.2, 510.1, 520.1, 511.1, 520.2, 511.1"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-5404",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-09T18:36:32.635602Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T17:28:37.686Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T07:59:44.850Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://process.honeywell.com"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "Experion Server",
              "vendor": "Honeywell",
              "versions": [
                {
                  "changes": [
                    {
                      "at": "520.2 TCU4 HF1",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.2 TCU4",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "510.2 HF14",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "510.2 HF13",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "520.1 TCU5",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.1 TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "511.5 TCU4 HF4",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "511.5 TCU4 HF3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion LX"
              ],
              "product": "Experion Server",
              "vendor": "Honeywell",
              "versions": [
                {
                  "changes": [
                    {
                      "at": "520.2 TCU4 HF2",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.2 TCU4",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "511.5 TCU4 HF4",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "511.5 TCU4 HF3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "520.1 TCU5",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.1 TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "PlantCruise by Experion"
              ],
              "product": "Experion Server",
              "vendor": "Honeywell",
              "versions": [
                {
                  "changes": [
                    {
                      "at": "520.2 TCU4 HF2",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.2 TCU4",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "520.1 TCU5",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "520.1 TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "changes": [
                    {
                      "at": "511.5 TCU4 HF4",
                      "status": "unaffected"
                    }
                  ],
                  "lessThanOrEqual": "511.5 TCU4 HF3",
                  "status": "affected",
                  "version": "520.2 TCU4 HFR2",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Server receiving a malformed message can cause a pointer to be overwritten which can result in a remote code execution or failure.\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSee Honeywell Security Notification for recommendations on upgrading and versioning.\u003c/span\u003e"
                }
              ],
              "value": "Server receiving a malformed message can cause a pointer to be overwritten which can result in a remote code execution or failure.\u00a0See Honeywell Security Notification for recommendations on upgrading and versioning."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-09T19:55:07.106Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "url": "https://process.honeywell.com"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2023-5404",
        "datePublished": "2024-04-17T16:44:37.703Z",
        "dateReserved": "2023-10-04T17:50:53.624Z",
        "dateUpdated": "2024-08-02T07:59:44.850Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-5403 (GCVE-0-2023-5403)

    Vulnerability from cvelistv5 – Published: 2024-04-17 16:43 – Updated: 2024-08-29 19:38
    VLAI
    Summary
    Server hostname translation to IP address manipulation which could lead to an attacker performing remote code execution or causing a failure. See Honeywell Security Notification for recommendations on upgrading and versioning.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Honeywell Experion Server Affected: 520.2 , ≤ 520.2 TCU4 (semver)
    Affected: 510.1 , ≤ 510.2 HF13 (semver)
    Affected: 520.1 , ≤ 520.1 TCU4 (semver)
    Affected: 511.1 , ≤ 511.5 TCU4 HF3 (semver)
    Create a notification for this product.
    Honeywell Experion Server Affected: 520.2 , ≤ 520.2 TCU4 (semver)
    Affected: 511.1 , ≤ 511.5 TCU4 HF3 (semver)
    Affected: 520.1 , ≤ 520.1 TCU4 (semver)
    Create a notification for this product.
    Honeywell Experion Server Affected: 520.2 , ≤ 520.2 TCU4 (semver)
    Affected: 520.1 , ≤ 520.1 TCU4 (semver)
    Affected: 520.2 TCU4 HFR2 , ≤ 511.5 TCU4 HF3 (semver)
    Create a notification for this product.
    honeywell experion_server Affected: 511.5tcu4hf3 , ≤ 20.2tcu4hfr2 (semver)
    Affected: 510.1 , ≤ 510.2_hf13 (semver)
    Affected: 520.1 , ≤ 520.1_tcu4 (semver)
    Affected: 511.1 , ≤ 511.5_tcu4_hf3 (semver)
    Affected: 520.2 , ≤ 520.2_tcu4 (semver)
        cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T07:59:44.423Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://process.honeywell.com"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "experion_server",
                "vendor": "honeywell",
                "versions": [
                  {
                    "lessThanOrEqual": "20.2tcu4hfr2",
                    "status": "affected",
                    "version": "511.5tcu4hf3",
                    "versionType": "semver"
                  },
                  {
                    "lessThanOrEqual": "510.2_hf13",
                    "status": "affected",
                    "version": "510.1",
                    "versionType": "semver"
                  },
                  {
                    "lessThanOrEqual": "520.1_tcu4",
                    "status": "affected",
                    "version": "520.1",
                    "versionType": "semver"
                  },
                  {
                    "lessThanOrEqual": "511.5_tcu4_hf3",
                    "status": "affected",
                    "version": "511.1",
                    "versionType": "semver"
                  },
                  {
                    "lessThanOrEqual": "520.2_tcu4",
                    "status": "affected",
                    "version": "520.2",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-5403",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-07T13:43:42.943158Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-29T19:38:53.821Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "Experion Server",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU4",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "510.2 HF13",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1 TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "511.5 TCU4 HF3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion LX"
              ],
              "product": "Experion Server",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU4",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "511.5 TCU4 HF3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1 TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "PlantCruise by Experion"
              ],
              "product": "Experion Server",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "520.2 TCU4",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1 TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "511.5 TCU4 HF3",
                  "status": "affected",
                  "version": "520.2 TCU4 HFR2",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Server hostname translation to IP address manipulation which could lead to an attacker performing remote code execution or causing a failure.\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSee Honeywell Security Notification for recommendations on upgrading and versioning.\u003c/span\u003e\n\n"
                }
              ],
              "value": "Server hostname translation to IP address manipulation which could lead to an attacker performing remote code execution or causing a failure.\n\nSee Honeywell Security Notification for recommendations on upgrading and versioning.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-25T17:00:27.977Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "url": "https://process.honeywell.com"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2023-5403",
        "datePublished": "2024-04-17T16:43:54.036Z",
        "dateReserved": "2023-10-04T17:50:52.659Z",
        "dateUpdated": "2024-08-29T19:38:53.821Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }