FKIE_CVE-2022-1229

Vulnerability from fkie_nvd - Published: 2023-03-28 19:15 - Updated: 2024-11-21 06:40
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.2.034. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of IFC files. Crafted data in an IFC file can trigger a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-16581.
Impacted products
Vendor Product Version
bentley microstation_connect 10.16.2.034

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:10.16.2.034:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E44AB8C-E719-4837-A762-20C25CE78744",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.2.034. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of IFC files. Crafted data in an IFC file can trigger a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-16581."
    }
  ],
  "id": "CVE-2022-1229",
  "lastModified": "2024-11-21T06:40:18.100",
  "metrics": {
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-03-28T19:15:10.050",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/be-2022-0006"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-615/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/be-2022-0006"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-615/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2022-41613

Vulnerability from fkie_nvd - Published: 2023-01-06 22:15 - Updated: 2025-02-13 17:15
Summary
Bentley Systems MicroStation Connect versions 10.17.0.209 and prior are vulnerable to an Out-of-Bounds Read when when parsing DGN files, which may allow an attacker to crash the product, disclose sensitive information, or execute arbitrary code.
Impacted products
Vendor Product Version
bentley microstation_connect *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E3956C1E-8FA0-436B-ACB8-152D523FE65B",
              "versionEndIncluding": "10.17.0.209",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Bentley Systems MicroStation Connect\u00a0versions \n\n10.17.0.209 and prior are vulnerable to an Out-of-Bounds Read when\u00a0when parsing DGN files, which may allow an attacker to crash the product, disclose sensitive information, or execute arbitrary code."
    },
    {
      "lang": "es",
      "value": "Las versiones 10.17.0.209 y anteriores de Bentley Systems MicroStation Connect son vulnerables a una lectura fuera de los l\u00edmites al analizar archivos DGN, lo que puede permitir a un atacante bloquear el producto, revelar informaci\u00f3n confidencial o ejecutar c\u00f3digo arbitrario."
    }
  ],
  "id": "CVE-2022-41613",
  "lastModified": "2025-02-13T17:15:43.773",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-01-06T22:15:09.403",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://www.bentley.com/advisories/be-2023-0003/"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-293-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.bentley.com/advisories/be-2023-0003/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-293-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2022-40201

Vulnerability from fkie_nvd - Published: 2023-01-06 22:15 - Updated: 2025-02-13 17:15
Summary
Bentley Systems MicroStation Connect versions 10.17.0.209 and prior are vulnerable to a Stack-Based Buffer Overflow when a malformed design (DGN) file is parsed. This may allow an attacker to execute arbitrary code.
Impacted products
Vendor Product Version
bentley microstation_connect *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E3956C1E-8FA0-436B-ACB8-152D523FE65B",
              "versionEndIncluding": "10.17.0.209",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Bentley Systems MicroStation Connect\u00a0versions \n\n10.17.0.209 and prior are vulnerable to a Stack-Based Buffer Overflow when a\u00a0malformed design (DGN) file is parsed. This may allow an attacker to execute arbitrary code."
    },
    {
      "lang": "es",
      "value": "Bentley Systems MicroStation Connect versiones 10.17.0.209 y anteriores son vulnerables a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria cuando se analiza un archivo design (DGN) con formato incorrecto. Esto puede permitir que un atacante ejecute c\u00f3digo arbitrario."
    }
  ],
  "id": "CVE-2022-40201",
  "lastModified": "2025-02-13T17:15:43.300",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-01-06T22:15:09.320",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://www.bentley.com/advisories/be-2023-0003/"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-293-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.bentley.com/advisories/be-2023-0003/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-293-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-46649

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-15535.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C2943C9E-CAF1-4DB9-9145-99231E290DF0",
              "versionEndExcluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to disclose sensitive information on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-15535."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos revelar informaci\u00f3n confidencial en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de los archivos DGN. El problema es debido a que no es comprobado apropiadamente los datos suministrados por el usuario, lo que puede resultar en una lectura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante puede aprovechar esto junto con otras vulnerabilidades para ejecutar c\u00f3digo arbitrario en el contexto del proceso actual. Era ZDI-CAN-15535"
    }
  ],
  "id": "CVE-2021-46649",
  "lastModified": "2024-11-21T06:34:31.277",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 3.3,
          "baseSeverity": "LOW",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 1.4,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:17.027",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-236/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-236/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-46650

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-15536.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C2943C9E-CAF1-4DB9-9145-99231E290DF0",
              "versionEndExcluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to disclose sensitive information on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-15536."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos revelar informaci\u00f3n confidencial en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de los archivos DGN. El problema es debido a que no es comprobado apropiadamente los datos suministrados por el usuario, lo que puede resultar en una lectura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante puede aprovechar esto junto con otras vulnerabilidades para ejecutar c\u00f3digo arbitrario en el contexto del proceso actual. Era ZDI-CAN-15536"
    }
  ],
  "id": "CVE-2021-46650",
  "lastModified": "2024-11-21T06:34:31.400",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 3.3,
          "baseSeverity": "LOW",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 1.4,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:17.080",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-237/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-237/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-46651

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-15537.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C2943C9E-CAF1-4DB9-9145-99231E290DF0",
              "versionEndExcluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to disclose sensitive information on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-15537."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos revelar informaci\u00f3n confidencial en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de los archivos DGN. El problema es debido a que no es comprobado apropiadamente los datos suministrados por el usuario, lo que puede resultar en una lectura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante puede aprovechar esto junto con otras vulnerabilidades para ejecutar c\u00f3digo arbitrario en el contexto del proceso actual. Era ZDI-CAN-15537"
    }
  ],
  "id": "CVE-2021-46651",
  "lastModified": "2024-11-21T06:34:31.530",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 3.3,
          "baseSeverity": "LOW",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 1.4,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:17.137",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-238/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-238/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-46647

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of BMP images. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15533.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C2943C9E-CAF1-4DB9-9145-99231E290DF0",
              "versionEndExcluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of BMP images. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15533."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de im\u00e1genes BMP. El problema es debido a que no es comprobada apropiadamente la longitud de los datos suministrados por el usuario antes de copiarlos en un b\u00fafer en la regi\u00f3n heap de la memoria. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. Era ZDI-CAN-15533"
    }
  ],
  "id": "CVE-2021-46647",
  "lastModified": "2024-11-21T06:34:31.033",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:16.910",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0002"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-234/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0002"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-234/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-122"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-46648

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15534.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C2943C9E-CAF1-4DB9-9145-99231E290DF0",
              "versionEndExcluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15534."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de los archivos DGN. El problema es debido a que no es comprobada apropiadamente la longitud de los datos suministrados por el usuario antes de copiarlos en un b\u00fafer en la regi\u00f3n heap de la memoria. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. Era ZDI-CAN-15534"
    }
  ],
  "id": "CVE-2021-46648",
  "lastModified": "2024-11-21T06:34:31.160",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:16.970",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-235/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-235/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-122"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-46635

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. Crafted data in a DGN file can trigger a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15507.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A37C35F2-BF78-43E7-B383-460788A7C0A6",
              "versionEndIncluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. Crafted data in a DGN file can trigger a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15507."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de los archivos DGN. Los datos dise\u00f1ados en un archivo DGN pueden desencadenar una escritura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. Era ZDI-CAN-15507"
    }
  ],
  "id": "CVE-2021-46635",
  "lastModified": "2024-11-21T06:34:29.460",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:16.233",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-222/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-222/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-46644

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. Crafted data in a DGN file can trigger a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15530.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C2943C9E-CAF1-4DB9-9145-99231E290DF0",
              "versionEndExcluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. Crafted data in a DGN file can trigger a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15530."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de los archivos DGN. Los datos dise\u00f1ados en un archivo DGN pueden desencadenar una escritura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. Era ZDI-CAN-15530"
    }
  ],
  "id": "CVE-2021-46644",
  "lastModified": "2024-11-21T06:34:30.660",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:16.743",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-231/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-231/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-46638

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15510.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A37C35F2-BF78-43E7-B383-460788A7C0A6",
              "versionEndIncluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15510."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de los archivos DGN. El problema es debido a que no es comprobada apropiadamente la longitud de los datos suministrados por el usuario antes de copiarlos en un b\u00fafer en la regi\u00f3n stack de la memoria. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. Era ZDI-CAN-15510"
    }
  ],
  "id": "CVE-2021-46638",
  "lastModified": "2024-11-21T06:34:29.870",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:16.407",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-225/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-225/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-46633

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of PDF files. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15463.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A37C35F2-BF78-43E7-B383-460788A7C0A6",
              "versionEndIncluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of PDF files. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15463."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de archivos PDF. El problema es debido a que no es comprobada la existencia de un objeto antes de llevar a cabo operaciones con \u00e9l. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. Era ZDI-CAN-15463"
    }
  ],
  "id": "CVE-2021-46633",
  "lastModified": "2024-11-21T06:34:29.207",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:16.070",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0003"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-220/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0003"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-220/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-416"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-46646

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. Crafted data in a DGN file can trigger a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15532.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C2943C9E-CAF1-4DB9-9145-99231E290DF0",
              "versionEndExcluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. Crafted data in a DGN file can trigger a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15532."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de los archivos DGN. Los datos dise\u00f1ados en un archivo DGN pueden desencadenar una escritura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. Era ZDI-CAN-15532"
    }
  ],
  "id": "CVE-2021-46646",
  "lastModified": "2024-11-21T06:34:30.910",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:16.853",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-233/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-233/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-46636

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. Crafted data in a DGN file can trigger a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15508.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A37C35F2-BF78-43E7-B383-460788A7C0A6",
              "versionEndIncluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. Crafted data in a DGN file can trigger a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15508."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de los archivos DGN. Los datos dise\u00f1ados en un archivo DGN pueden desencadenar una lectura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. Era ZDI-CAN-15508"
    }
  ],
  "id": "CVE-2021-46636",
  "lastModified": "2024-11-21T06:34:29.593",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:16.297",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-223/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-223/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-46639

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. Crafted data in a DGN file can trigger a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15511.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A37C35F2-BF78-43E7-B383-460788A7C0A6",
              "versionEndIncluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. Crafted data in a DGN file can trigger a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15511."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de los archivos DGN. Los datos dise\u00f1ados en un archivo DGN pueden desencadenar una escritura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. Era ZDI-CAN-15511"
    }
  ],
  "id": "CVE-2021-46639",
  "lastModified": "2024-11-21T06:34:30.010",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:16.463",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-226/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-226/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-46634

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of JT files. Crafted data in a JT file can trigger a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15464.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A37C35F2-BF78-43E7-B383-460788A7C0A6",
              "versionEndIncluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of JT files. Crafted data in a JT file can trigger a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15464."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de los archivos JT. Los datos dise\u00f1ados en un archivo JT pueden desencadenar una escritura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. Era ZDI-CAN-15464"
    }
  ],
  "id": "CVE-2021-46634",
  "lastModified": "2024-11-21T06:34:29.327",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:16.127",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0005"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-221/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0005"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-221/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-46645

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of BMP images. Crafted data in a BMP image can trigger a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15531.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A4677CD-F08B-4FFB-BA39-21E756173123",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61C38C7C-A2B7-4670-9EA3-10F6B3075DEE",
              "versionEndExcluding": "10.16.0.80",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of BMP images. Crafted data in a BMP image can trigger a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15531."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de las im\u00e1genes BMP. Los datos dise\u00f1ados en una imagen BMP pueden desencadenar una escritura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. Era ZDI-CAN-15531"
    }
  ],
  "id": "CVE-2021-46645",
  "lastModified": "2024-11-21T06:34:30.780",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:16.800",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0002"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-232/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0002"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-232/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-46637

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-15509.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A37C35F2-BF78-43E7-B383-460788A7C0A6",
              "versionEndIncluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to disclose sensitive information on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-15509."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos revelar informaci\u00f3n confidencial en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de los archivos DGN. El problema es debido a que no es comprobado apropiadamente los datos suministrados por el usuario, lo que puede resultar en una lectura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante puede aprovechar esto junto con otras vulnerabilidades para ejecutar c\u00f3digo arbitrario en el contexto del proceso actual. Era ZDI-CAN-15509"
    }
  ],
  "id": "CVE-2021-46637",
  "lastModified": "2024-11-21T06:34:29.737",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 3.3,
          "baseSeverity": "LOW",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 1.4,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:16.353",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-224/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0009"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-224/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-46620

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of FBX files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-15414.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A37C35F2-BF78-43E7-B383-460788A7C0A6",
              "versionEndIncluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to disclose sensitive information on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of FBX files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-15414."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos revelar informaci\u00f3n confidencial en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de los archivos FBX. El problema es debido a que no es comprobado apropiadamente los datos suministrados por el usuario, lo que puede resultar en una lectura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante puede aprovechar esto junto con otras vulnerabilidades para ejecutar c\u00f3digo arbitrario en el contexto del proceso actual. Era ZDI-CAN-15414"
    }
  ],
  "id": "CVE-2021-46620",
  "lastModified": "2024-11-21T06:34:27.477",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 3.3,
          "baseSeverity": "LOW",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 1.4,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:15.303",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0012"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-207/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0012"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-207/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-46618

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of PNG images. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-15412.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A37C35F2-BF78-43E7-B383-460788A7C0A6",
              "versionEndIncluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to disclose sensitive information on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of PNG images. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-15412."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos revelar informaci\u00f3n confidencial en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de las im\u00e1genes PNG. El problema es debido a que no es comprobado apropiadamente los datos suministrados por el usuario, lo que puede resultar en una lectura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante puede aprovechar esto junto con otras vulnerabilidades para ejecutar c\u00f3digo arbitrario en el contexto del proceso actual. Era ZDI-CAN-15412"
    }
  ],
  "id": "CVE-2021-46618",
  "lastModified": "2024-11-21T06:34:27.230",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 3.3,
          "baseSeverity": "LOW",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 1.4,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:15.170",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0013"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-205/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0013"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-205/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-46619

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of PDF files. Crafted data in a PDF file can trigger a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15413.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A37C35F2-BF78-43E7-B383-460788A7C0A6",
              "versionEndIncluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of PDF files. Crafted data in a PDF file can trigger a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15413."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de los archivos PDF. Los datos dise\u00f1ados en un archivo PDF pueden desencadenar una lectura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. Era ZDI-CAN-15413"
    }
  ],
  "id": "CVE-2021-46619",
  "lastModified": "2024-11-21T06:34:27.357",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:15.237",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0003"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-206/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0003"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-206/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-46616

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of BMP images. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-15410.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A37C35F2-BF78-43E7-B383-460788A7C0A6",
              "versionEndIncluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to disclose sensitive information on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of BMP images. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-15410."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos revelar informaci\u00f3n confidencial en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de im\u00e1genes BMP. El problema es debido a que no es comprobado apropiadamente los datos suministrados por el usuario, lo que puede resultar en una lectura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante puede aprovechar esto junto con otras vulnerabilidades para ejecutar c\u00f3digo arbitrario en el contexto del proceso actual. Era ZDI-CAN-15410"
    }
  ],
  "id": "CVE-2021-46616",
  "lastModified": "2024-11-21T06:34:26.987",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 3.3,
          "baseSeverity": "LOW",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 1.4,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:15.053",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0002"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-203/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0002"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-203/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-46622

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of J2K images. Crafted data in a J2K image can trigger a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15416.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A37C35F2-BF78-43E7-B383-460788A7C0A6",
              "versionEndIncluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of J2K images. Crafted data in a J2K image can trigger a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15416."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de las im\u00e1genes J2K. Los datos dise\u00f1ados en una imagen J2K pueden desencadenar una lectura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. Era ZDI-CAN-15416"
    }
  ],
  "id": "CVE-2021-46622",
  "lastModified": "2024-11-21T06:34:27.730",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:15.427",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0006"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-209/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0006"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-209/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-46617

Vulnerability from fkie_nvd - Published: 2022-02-18 20:15 - Updated: 2024-11-21 06:34
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of TIF images. The issue results from the lack of proper initialization of memory prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15411.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1208828E-B97A-4A25-90B5-7E6056BAC773",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:microstation_connect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A37C35F2-BF78-43E7-B383-460788A7C0A6",
              "versionEndIncluding": "10.16.0.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0235FC-D554-4E17-8E89-2BB625B91ED0",
              "versionEndExcluding": "10.16.02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of TIF images. The issue results from the lack of proper initialization of memory prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15411."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Bentley MicroStation CONNECT versi\u00f3n 10.16.0.80. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de im\u00e1genes TIF. El problema es debido a una falta de inicializaci\u00f3n apropiada de la memoria antes de acceder a ella. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. Era ZDI-CAN-15411"
    }
  ],
  "id": "CVE-2021-46617",
  "lastModified": "2024-11-21T06:34:27.103",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-18T20:15:15.113",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0015"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-204/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0015"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-204/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-457"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

CVE-2022-1229 (GCVE-0-2022-1229)

Vulnerability from cvelistv5 – Published: 2023-03-28 00:00 – Updated: 2025-02-19 15:42
VLAI?
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.2.034. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of IFC files. Crafted data in an IFC file can trigger a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-16581.
CWE
Assigner
zdi
Impacted products
Vendor Product Version
Bentley MicroStation CONNECT Affected: 10.16.2.034
Create a notification for this product.
Credits
Anonymous
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T23:55:24.542Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-615/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.bentley.com/en/common-vulnerability-exposure/be-2022-0006"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-1229",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-19T15:42:36.816130Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-19T15:42:40.654Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "MicroStation CONNECT",
          "vendor": "Bentley",
          "versions": [
            {
              "status": "affected",
              "version": "10.16.2.034"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Anonymous"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.2.034. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of IFC files. Crafted data in an IFC file can trigger a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-16581."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T00:00:00.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-615/"
        },
        {
          "url": "https://www.bentley.com/en/common-vulnerability-exposure/be-2022-0006"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2022-1229",
    "datePublished": "2023-03-28T00:00:00.000Z",
    "dateReserved": "2022-04-04T00:00:00.000Z",
    "dateUpdated": "2025-02-19T15:42:40.654Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-41613 (GCVE-0-2022-41613)

Vulnerability from cvelistv5 – Published: 2023-01-06 21:11 – Updated: 2025-02-13 16:33
VLAI?
Summary
Bentley Systems MicroStation Connect versions 10.17.0.209 and prior are vulnerable to an Out-of-Bounds Read when when parsing DGN files, which may allow an attacker to crash the product, disclose sensitive information, or execute arbitrary code.
CWE
Assigner
Impacted products
Vendor Product Version
Bentley Systems MicroStation Connect Affected: 0 , ≤ 10.17.0.209 (custom)
Create a notification for this product.
Credits
Michael Heinzl
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T12:49:43.409Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-293-01"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.bentley.com/advisories/be-2023-0003/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MicroStation Connect",
          "vendor": "Bentley Systems",
          "versions": [
            {
              "lessThanOrEqual": "10.17.0.209",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Michael Heinzl"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eBentley Systems MicroStation Connect\u003c/span\u003e\u0026nbsp;versions \n\n10.17.0.209 and prior are vulnerable to an Out-of-Bounds Read when\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ewhen parsing DGN files, which may allow an attacker to crash the product, disclose sensitive information, or execute arbitrary code.\u003c/span\u003e\n\n\u003c/span\u003e"
            }
          ],
          "value": "Bentley Systems MicroStation Connect\u00a0versions \n\n10.17.0.209 and prior are vulnerable to an Out-of-Bounds Read when\u00a0when parsing DGN files, which may allow an attacker to crash the product, disclose sensitive information, or execute arbitrary code."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-02T05:13:01.823Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-293-01"
        },
        {
          "url": "https://www.bentley.com/advisories/be-2023-0003/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eBentley Systems has implemented multiple validation checks within the DGN platform when processing malformed DGNs. Bentley Systems recommends users update to the latest version of the MicroStation Connect:\u003c/p\u003e\u003cul\u003e\u003cli\u003eMicroStation Connect Update 17.1\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor more information and MicroStation updates, contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.bentley.com/support/\"\u003eBentley Support\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Bentley Systems has implemented multiple validation checks within the DGN platform when processing malformed DGNs. Bentley Systems recommends users update to the latest version of the MicroStation Connect:\n\n  *  MicroStation Connect Update 17.1\n\n\nFor more information and MicroStation updates, contact  Bentley Support https://www.bentley.com/support/ ."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-41613",
    "datePublished": "2023-01-06T21:11:43.209Z",
    "dateReserved": "2022-09-29T14:08:03.169Z",
    "dateUpdated": "2025-02-13T16:33:05.319Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-40201 (GCVE-0-2022-40201)

Vulnerability from cvelistv5 – Published: 2023-01-06 21:10 – Updated: 2025-02-13 16:33
VLAI?
Summary
Bentley Systems MicroStation Connect versions 10.17.0.209 and prior are vulnerable to a Stack-Based Buffer Overflow when a malformed design (DGN) file is parsed. This may allow an attacker to execute arbitrary code.
CWE
  • CWE-121 - Stack-Based Buffer Overflow
Assigner
Impacted products
Vendor Product Version
Bentley Systems MicroStation Connect Affected: 0 , ≤ 10.17.0.209 (custom)
Create a notification for this product.
Credits
Michael Heinzl
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:bentley:microstation_connect:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "microstation_connect",
            "vendor": "bentley",
            "versions": [
              {
                "lessThanOrEqual": "10.17.0.209",
                "status": "affected",
                "version": "-",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-40201",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-08T14:45:11.115441Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:15:41.110Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T12:14:39.671Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-293-01"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.bentley.com/advisories/be-2023-0003/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MicroStation Connect",
          "vendor": "Bentley Systems",
          "versions": [
            {
              "lessThanOrEqual": "10.17.0.209",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Michael Heinzl"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eBentley Systems MicroStation Connect\u003c/span\u003e\u0026nbsp;versions \n\n10.17.0.209 and prior are vulnerable to a Stack-Based Buffer Overflow when a\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003emalformed design (DGN) file is parsed. This may allow an attacker to execute arbitrary code.\u003c/span\u003e"
            }
          ],
          "value": "Bentley Systems MicroStation Connect\u00a0versions \n\n10.17.0.209 and prior are vulnerable to a Stack-Based Buffer Overflow when a\u00a0malformed design (DGN) file is parsed. This may allow an attacker to execute arbitrary code."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-Based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-02T05:12:23.789Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-293-01"
        },
        {
          "url": "https://www.bentley.com/advisories/be-2023-0003/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eBentley Systems has implemented multiple validation checks within the DGN platform when processing malformed DGNs. Bentley Systems recommends users update to the latest version of the MicroStation Connect:\u003c/p\u003e\u003cul\u003e\u003cli\u003eMicroStation Connect Update 17.1\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor more information and MicroStation updates, contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.bentley.com/support/\"\u003eBentley Support\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Bentley Systems has implemented multiple validation checks within the DGN platform when processing malformed DGNs. Bentley Systems recommends users update to the latest version of the MicroStation Connect:\n\n  *  MicroStation Connect Update 17.1\n\n\nFor more information and MicroStation updates, contact  Bentley Support https://www.bentley.com/support/ ."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-40201",
    "datePublished": "2023-01-06T21:10:43.968Z",
    "dateReserved": "2022-09-29T14:08:03.156Z",
    "dateUpdated": "2025-02-13T16:33:01.388Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-1229 (GCVE-0-2022-1229)

Vulnerability from nvd – Published: 2023-03-28 00:00 – Updated: 2025-02-19 15:42
VLAI?
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.2.034. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of IFC files. Crafted data in an IFC file can trigger a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-16581.
CWE
Assigner
zdi
Impacted products
Vendor Product Version
Bentley MicroStation CONNECT Affected: 10.16.2.034
Create a notification for this product.
Credits
Anonymous
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T23:55:24.542Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-615/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.bentley.com/en/common-vulnerability-exposure/be-2022-0006"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-1229",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-19T15:42:36.816130Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-19T15:42:40.654Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "MicroStation CONNECT",
          "vendor": "Bentley",
          "versions": [
            {
              "status": "affected",
              "version": "10.16.2.034"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Anonymous"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.2.034. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of IFC files. Crafted data in an IFC file can trigger a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-16581."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T00:00:00.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-615/"
        },
        {
          "url": "https://www.bentley.com/en/common-vulnerability-exposure/be-2022-0006"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2022-1229",
    "datePublished": "2023-03-28T00:00:00.000Z",
    "dateReserved": "2022-04-04T00:00:00.000Z",
    "dateUpdated": "2025-02-19T15:42:40.654Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-41613 (GCVE-0-2022-41613)

Vulnerability from nvd – Published: 2023-01-06 21:11 – Updated: 2025-02-13 16:33
VLAI?
Summary
Bentley Systems MicroStation Connect versions 10.17.0.209 and prior are vulnerable to an Out-of-Bounds Read when when parsing DGN files, which may allow an attacker to crash the product, disclose sensitive information, or execute arbitrary code.
CWE
Assigner
Impacted products
Vendor Product Version
Bentley Systems MicroStation Connect Affected: 0 , ≤ 10.17.0.209 (custom)
Create a notification for this product.
Credits
Michael Heinzl
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T12:49:43.409Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-293-01"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.bentley.com/advisories/be-2023-0003/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MicroStation Connect",
          "vendor": "Bentley Systems",
          "versions": [
            {
              "lessThanOrEqual": "10.17.0.209",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Michael Heinzl"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eBentley Systems MicroStation Connect\u003c/span\u003e\u0026nbsp;versions \n\n10.17.0.209 and prior are vulnerable to an Out-of-Bounds Read when\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ewhen parsing DGN files, which may allow an attacker to crash the product, disclose sensitive information, or execute arbitrary code.\u003c/span\u003e\n\n\u003c/span\u003e"
            }
          ],
          "value": "Bentley Systems MicroStation Connect\u00a0versions \n\n10.17.0.209 and prior are vulnerable to an Out-of-Bounds Read when\u00a0when parsing DGN files, which may allow an attacker to crash the product, disclose sensitive information, or execute arbitrary code."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-02T05:13:01.823Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-293-01"
        },
        {
          "url": "https://www.bentley.com/advisories/be-2023-0003/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eBentley Systems has implemented multiple validation checks within the DGN platform when processing malformed DGNs. Bentley Systems recommends users update to the latest version of the MicroStation Connect:\u003c/p\u003e\u003cul\u003e\u003cli\u003eMicroStation Connect Update 17.1\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor more information and MicroStation updates, contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.bentley.com/support/\"\u003eBentley Support\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Bentley Systems has implemented multiple validation checks within the DGN platform when processing malformed DGNs. Bentley Systems recommends users update to the latest version of the MicroStation Connect:\n\n  *  MicroStation Connect Update 17.1\n\n\nFor more information and MicroStation updates, contact  Bentley Support https://www.bentley.com/support/ ."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-41613",
    "datePublished": "2023-01-06T21:11:43.209Z",
    "dateReserved": "2022-09-29T14:08:03.169Z",
    "dateUpdated": "2025-02-13T16:33:05.319Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-40201 (GCVE-0-2022-40201)

Vulnerability from nvd – Published: 2023-01-06 21:10 – Updated: 2025-02-13 16:33
VLAI?
Summary
Bentley Systems MicroStation Connect versions 10.17.0.209 and prior are vulnerable to a Stack-Based Buffer Overflow when a malformed design (DGN) file is parsed. This may allow an attacker to execute arbitrary code.
CWE
  • CWE-121 - Stack-Based Buffer Overflow
Assigner
Impacted products
Vendor Product Version
Bentley Systems MicroStation Connect Affected: 0 , ≤ 10.17.0.209 (custom)
Create a notification for this product.
Credits
Michael Heinzl
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:bentley:microstation_connect:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "microstation_connect",
            "vendor": "bentley",
            "versions": [
              {
                "lessThanOrEqual": "10.17.0.209",
                "status": "affected",
                "version": "-",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-40201",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-08T14:45:11.115441Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:15:41.110Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T12:14:39.671Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-293-01"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.bentley.com/advisories/be-2023-0003/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MicroStation Connect",
          "vendor": "Bentley Systems",
          "versions": [
            {
              "lessThanOrEqual": "10.17.0.209",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Michael Heinzl"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eBentley Systems MicroStation Connect\u003c/span\u003e\u0026nbsp;versions \n\n10.17.0.209 and prior are vulnerable to a Stack-Based Buffer Overflow when a\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003emalformed design (DGN) file is parsed. This may allow an attacker to execute arbitrary code.\u003c/span\u003e"
            }
          ],
          "value": "Bentley Systems MicroStation Connect\u00a0versions \n\n10.17.0.209 and prior are vulnerable to a Stack-Based Buffer Overflow when a\u00a0malformed design (DGN) file is parsed. This may allow an attacker to execute arbitrary code."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-Based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-02T05:12:23.789Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-293-01"
        },
        {
          "url": "https://www.bentley.com/advisories/be-2023-0003/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eBentley Systems has implemented multiple validation checks within the DGN platform when processing malformed DGNs. Bentley Systems recommends users update to the latest version of the MicroStation Connect:\u003c/p\u003e\u003cul\u003e\u003cli\u003eMicroStation Connect Update 17.1\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor more information and MicroStation updates, contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.bentley.com/support/\"\u003eBentley Support\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Bentley Systems has implemented multiple validation checks within the DGN platform when processing malformed DGNs. Bentley Systems recommends users update to the latest version of the MicroStation Connect:\n\n  *  MicroStation Connect Update 17.1\n\n\nFor more information and MicroStation updates, contact  Bentley Support https://www.bentley.com/support/ ."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-40201",
    "datePublished": "2023-01-06T21:10:43.968Z",
    "dateReserved": "2022-09-29T14:08:03.156Z",
    "dateUpdated": "2025-02-13T16:33:01.388Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}