Search criteria
3 vulnerabilities found for multilin_sr_745_transformer_protection_relay_firmware by ge
FKIE_CVE-2017-7905
Vulnerability from fkie_nvd - Published: 2017-06-30 03:29 - Updated: 2025-04-20 01:37
Severity ?
Summary
A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/98063 | Third Party Advisory, VDB Entry | |
| ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-17-117-01A | Patch, Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/98063 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-17-117-01A | Patch, Third Party Advisory, US Government Resource |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ge:multilin_sr_750_feeder_protection_relay_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F9CDB455-F6F8-4976-95D2-88D21720DE88",
"versionEndIncluding": "5.02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ge:multilin_sr_750_feeder_protection_relay:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6E636C33-148B-4C26-96B3-CA0D1575C26D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ge:multilin_sr_760_feeder_protection_relay_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FDE8714B-96AC-4A85-ADCC-D00F54803596",
"versionEndIncluding": "5.02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ge:multilin_sr_760_feeder_protection_relay:-:*:*:*:*:*:*:*",
"matchCriteriaId": "22504FF2-C1B7-406C-B253-ED7982A624D5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ge:multilin_sr_469_motor_protection_relay_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9928DE28-CE5A-4AC2-A956-D128764720BA",
"versionEndIncluding": "2.90",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ge:multilin_sr_469_motor_protection_relay:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D6A23088-B5C4-4B0A-9E92-12946555C8A0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ge:multilin_sr_489_generator_protection_relay_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8766AA67-18A8-4440-BED6-E6BBDF3EF78D",
"versionEndIncluding": "1.53",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ge:multilin_sr_489_generator_protection_relay:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E899C89E-89EE-4FC1-809D-E6DB04989B28",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ge:multilin_sr_745_transformer_protection_relay_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F032369D-581E-4FCA-85CA-B932CB1E821D",
"versionEndIncluding": "2.85",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ge:multilin_sr_745_transformer_protection_relay:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DA36A160-426F-4911-9CF3-28E496AEDDB7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ge:multilin_sr_369_motor_protection_relay_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "32F15979-2C0D-4DD6-BA35-C5300EEF752D",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ge:multilin_sr_369_motor_protection_relay:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1CA749D2-FCF4-4936-84AA-EF317BB6DEEB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ge:multilin_universal_relay_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C329C25F-D48E-4B39-8FDB-88CE14E1D285",
"versionEndIncluding": "6.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ge:multilin_universal_relay:-:*:*:*:*:*:*:*",
"matchCriteriaId": "84392E96-D1C4-438C-ABA9-DE1384623D5A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ge:multilin_urplus_d90_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "36F9ACC9-EDE7-42E8-AF34-057EA862147D",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ge:multilin_urplus_d90:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3C697E8E-28F2-43F9-9B7D-0BF939B2F220",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ge:multilin_urplus_c90_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DBEF4ACF-7851-4EA2-B6E8-D60DB0BC660B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ge:multilin_urplus_c90:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E16FE6EA-BB44-4B73-BFA5-30E1ADF5D522",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ge:multilin_urplus_b95_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "11D188B6-4ADD-4FA6-9FF4-35B813911398",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ge:multilin_urplus_b95:-:*:*:*:*:*:*:*",
"matchCriteriaId": "93C57507-A23D-4DF7-9D9B-3531F2235132",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands."
},
{
"lang": "es",
"value": "Se ha descubierto un problema de criptograf\u00eda d\u00e9bil para contrase\u00f1as en General Electric (GE) Multilin SR 750 Feeder Protection Relay con versiones de firmware anteriores a la versi\u00f3n 7.47."
}
],
"id": "CVE-2017-7905",
"lastModified": "2025-04-20T01:37:25.860",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": true,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2017-06-30T03:29:00.890",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/98063"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-117-01A"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/98063"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-117-01A"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-261"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-326"
},
{
"lang": "en",
"value": "CWE-330"
},
{
"lang": "en",
"value": "CWE-522"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2017-7905 (GCVE-0-2017-7905)
Vulnerability from cvelistv5 – Published: 2017-06-30 02:35 – Updated: 2024-08-05 16:19
VLAI?
Summary
A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | GE Multilin SR, UR, and URplus Protective Relays |
Affected:
GE Multilin SR, UR, and URplus Protective Relays
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:19:29.324Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "98063",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/98063"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-117-01A"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GE Multilin SR, UR, and URplus Protective Relays",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "GE Multilin SR, UR, and URplus Protective Relays"
}
]
}
],
"datePublic": "2017-06-29T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-261",
"description": "CWE-261",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-06-30T09:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "98063",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/98063"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-117-01A"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2017-7905",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GE Multilin SR, UR, and URplus Protective Relays",
"version": {
"version_data": [
{
"version_value": "GE Multilin SR, UR, and URplus Protective Relays"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-261"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "98063",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/98063"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-117-01A",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-117-01A"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2017-7905",
"datePublished": "2017-06-30T02:35:00",
"dateReserved": "2017-04-18T00:00:00",
"dateUpdated": "2024-08-05T16:19:29.324Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-7905 (GCVE-0-2017-7905)
Vulnerability from nvd – Published: 2017-06-30 02:35 – Updated: 2024-08-05 16:19
VLAI?
Summary
A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | GE Multilin SR, UR, and URplus Protective Relays |
Affected:
GE Multilin SR, UR, and URplus Protective Relays
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:19:29.324Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "98063",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/98063"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-117-01A"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GE Multilin SR, UR, and URplus Protective Relays",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "GE Multilin SR, UR, and URplus Protective Relays"
}
]
}
],
"datePublic": "2017-06-29T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-261",
"description": "CWE-261",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-06-30T09:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "98063",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/98063"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-117-01A"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2017-7905",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GE Multilin SR, UR, and URplus Protective Relays",
"version": {
"version_data": [
{
"version_value": "GE Multilin SR, UR, and URplus Protective Relays"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-261"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "98063",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/98063"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-117-01A",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-117-01A"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2017-7905",
"datePublished": "2017-06-30T02:35:00",
"dateReserved": "2017-04-18T00:00:00",
"dateUpdated": "2024-08-05T16:19:29.324Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}