Search criteria

9 vulnerabilities found for multilink_ml2400_firmware by ge

FKIE_CVE-2015-3976

Vulnerability from fkie_nvd - Published: 2017-08-28 15:29 - Updated: 2025-11-05 00:15

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml810_firmware:5.2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "26502C62-8445-45C8-B099-02513595D002",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml810:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81DC26E5-D3D7-41C6-B654-B06FA0461451",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml3000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8CCA289-8E58-41E9-9AD3-860A6B373EE3",
              "versionEndIncluding": "5.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml3000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EE40202-1D8F-406E-8281-B67DCF5E8501",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml3100_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "339C1069-C126-4840-92DC-0DBE17FD764C",
              "versionEndIncluding": "5.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml3100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D72F9922-A473-4076-91E3-CF3899C179D7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml800_firmware:4.2.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "83DE9D2A-3A96-4051-9C69-0B0C9EA26EE4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9A00E85C-1B21-43F7-8323-F759216BFB90",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml1200_firmware:4.2.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8A95DAC-C62C-451A-9613-123FECFB9627",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml1200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1179F179-510A-4A97-8365-B81C0E0FC605",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml1600_firmware:4.2.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "256CB390-1BAB-41E3-89AA-98BA88114D84",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml1600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "620703E4-1D78-44CB-B353-517A8AB2A815",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml2400_firmware:4.2.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB917F77-2933-4877-A8A2-C6364D6DCE0A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml2400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "426A283A-540C-43F2-8397-52668BADDEB8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Cross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de tipo Cross-Site Scripting (XSS) en GE Multilink ML810/3000/3100 series switch 5.2.0 y anteriores y en GE Multilink ML800/1200/1600/2400 4.2.1 y anteriores."
    }
  ],
  "id": "CVE-2015-3976",
  "lastModified": "2025-11-05T00:15:34.387",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 6.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:N/I:C/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary",
        "userInteractionRequired": true
      },
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.4,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "LOW",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 2.3,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2017-08-28T15:29:01.453",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2015/icsa-15-013-04a.json"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-013-04a"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04A"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2014-5419

Vulnerability from fkie_nvd - Published: 2015-01-17 02:59 - Updated: 2025-11-05 00:15
Severity ?
Summary
GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier use the same RSA private key across different customers' installations, which makes it easier for remote attackers to obtain the cleartext content of network traffic by reading this key from a firmware image and then sniffing the network.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml3100_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "339C1069-C126-4840-92DC-0DBE17FD764C",
              "versionEndIncluding": "5.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml3100:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A16124C-6614-4EF1-912B-D16145997AF6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml3000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8CCA289-8E58-41E9-9AD3-860A6B373EE3",
              "versionEndIncluding": "5.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml3000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "359B13A0-4CCC-4E7A-A5C0-BF568EE01282",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml810_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D14EC388-6D6C-49BA-9436-9708236B5BD0",
              "versionEndIncluding": "5.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml810:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81DC26E5-D3D7-41C6-B654-B06FA0461451",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml1600_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2F6933C-8017-4BE1-82D3-81785EA99BB6",
              "versionEndIncluding": "4.2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml1600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "620703E4-1D78-44CB-B353-517A8AB2A815",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml800_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12A4D84B-AA33-4FC4-BBDF-AD0A0324D80F",
              "versionEndIncluding": "4.2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9A00E85C-1B21-43F7-8323-F759216BFB90",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml2400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F63F2FB-8E3A-4691-A74E-32DA333030DC",
              "versionEndIncluding": "4.2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml2400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "426A283A-540C-43F2-8397-52668BADDEB8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml1200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "220E7CFA-4C66-498A-B0FA-1F4362D50732",
              "versionEndIncluding": "4.2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml1200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1179F179-510A-4A97-8365-B81C0E0FC605",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier use the same RSA private key across different customers\u0027 installations, which makes it easier for remote attackers to obtain the cleartext content of network traffic by reading this key from a firmware image and then sniffing the network."
    },
    {
      "lang": "es",
      "value": "Los switches GE Multilink ML800, ML1200, ML1600, y ML2400 con firmware 4.2.1 y anteriores y los switches Multilink ML810, ML3000, y ML3100 con firmware 5.2.0 y anteriores utilizan la misma clave RSA privada en instalaciones diferentes de cliente, lo que facilita a atacantes remotos obtener el contenido en texto plano de trafico de la red mediante la lectura de esta clave de una imagen de firmware y posteriormente la captura de trafico de la red."
    }
  ],
  "id": "CVE-2014-5419",
  "lastModified": "2025-11-05T00:15:34.213",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary",
        "userInteractionRequired": false
      },
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2015-01-17T02:59:02.600",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2015/icsa-15-013-04a.json"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-013-04a"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-321"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-310"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2014-5418

Vulnerability from fkie_nvd - Published: 2015-01-17 02:59 - Updated: 2025-11-05 00:15

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml810_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D14EC388-6D6C-49BA-9436-9708236B5BD0",
              "versionEndIncluding": "5.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml810:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81DC26E5-D3D7-41C6-B654-B06FA0461451",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml1600_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2F6933C-8017-4BE1-82D3-81785EA99BB6",
              "versionEndIncluding": "4.2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml1600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "620703E4-1D78-44CB-B353-517A8AB2A815",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml1200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "220E7CFA-4C66-498A-B0FA-1F4362D50732",
              "versionEndIncluding": "4.2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml1200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1179F179-510A-4A97-8365-B81C0E0FC605",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml3000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8CCA289-8E58-41E9-9AD3-860A6B373EE3",
              "versionEndIncluding": "5.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml3000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "359B13A0-4CCC-4E7A-A5C0-BF568EE01282",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml2400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F63F2FB-8E3A-4691-A74E-32DA333030DC",
              "versionEndIncluding": "4.2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml2400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "426A283A-540C-43F2-8397-52668BADDEB8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml3100_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "339C1069-C126-4840-92DC-0DBE17FD764C",
              "versionEndIncluding": "5.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml3100:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A16124C-6614-4EF1-912B-D16145997AF6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ge:multilink_ml800_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12A4D84B-AA33-4FC4-BBDF-AD0A0324D80F",
              "versionEndIncluding": "4.2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ge:multilink_ml800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9A00E85C-1B21-43F7-8323-F759216BFB90",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets."
    },
    {
      "lang": "es",
      "value": "Los switches GE Multilink ML800, ML1200, ML1600, y ML2400 con firmware 4.2.1 y anteriores y los switches Multilink ML810, ML3000, y ML3100 con firmware 5.2.0 y anteriores permiten a atacantes remotos causar una denegaci\u00f3n de servicio (consumo de recursos o reinicio) a trav\u00e9s de paquetes manipulados."
    }
  ],
  "id": "CVE-2014-5418",
  "lastModified": "2025-11-05T00:15:34.043",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary",
        "userInteractionRequired": false
      },
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2015-01-17T02:59:01.223",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2015/icsa-15-013-04a.json"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-013-04a"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-399"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

CVE-2015-3976 (GCVE-0-2015-3976)

Vulnerability from cvelistv5 – Published: 2017-08-28 15:00 – Updated: 2025-11-04 23:33
VLAI?
Summary
Cross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
GE Multilink ML800/1200/1600/2400 Affected: 0 , ≤ 4.2.1 (custom)
Create a notification for this product.
Credits
Eireann Leverett of IOActive
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T06:04:02.453Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04A"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Multilink ML800/1200/1600/2400",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "4.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ML810/3000/3100 series switch",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "5.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Eireann Leverett of IOActive"
        }
      ],
      "datePublic": "2015-01-13T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\n\nCross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier.\n\n\u003c/p\u003e"
            }
          ],
          "value": "Cross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "confidentialityImpact": "NONE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:C/A:N",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-04T23:33:49.742Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-013-04a"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2015/icsa-15-013-04a.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eGE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.gedigitalenergy.com\"\u003ehttp://www.gedigitalenergy.com\u003c/a\u003e. This firmware is also available through \nthe EnerVista Launchpad device management tool.\u003c/p\u003e\n\u003cp\u003eGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\u003c/p\u003e\n\u003cp\u003ePlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\"\u003ehttps://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "GE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n http://www.gedigitalenergy.com . This firmware is also available through \nthe EnerVista Launchpad device management tool.\n\n\nGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\n\n\nPlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\n\n\n https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf"
        }
      ],
      "source": {
        "advisory": "ICSA-15-013-04",
        "discovery": "EXTERNAL"
      },
      "title": "GE Multilink Cross-site Scripting",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-5418",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04"
            },
            {
              "name": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2015-3976",
    "datePublished": "2017-08-28T15:00:00",
    "dateReserved": "2015-05-12T00:00:00",
    "dateUpdated": "2025-11-04T23:33:49.742Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2014-5418 (GCVE-0-2014-5418)

Vulnerability from cvelistv5 – Published: 2015-01-17 02:00 – Updated: 2025-11-04 23:30
VLAI?
Summary
GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
GE Multilink ML800/1200/1600/2400 Affected: 0 , ≤ 4.2.1 (custom)
Create a notification for this product.
Credits
Eireann Leverett of IOActive
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T11:41:49.173Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Multilink ML800/1200/1600/2400",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "4.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ML810/3000/3100 series switch",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "5.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Eireann Leverett of IOActive"
        }
      ],
      "datePublic": "2015-01-13T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eGE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets.\u003c/p\u003e"
            }
          ],
          "value": "GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5,
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-04T23:30:32.557Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-013-04a"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2015/icsa-15-013-04a.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eGE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.gedigitalenergy.com\"\u003ehttp://www.gedigitalenergy.com\u003c/a\u003e. This firmware is also available through \nthe EnerVista Launchpad device management tool.\u003c/p\u003e\n\u003cp\u003eGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\u003c/p\u003e\n\u003cp\u003ePlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\"\u003ehttps://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "GE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n http://www.gedigitalenergy.com . This firmware is also available through \nthe EnerVista Launchpad device management tool.\n\n\nGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\n\n\nPlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\n\n\n https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf"
        }
      ],
      "source": {
        "advisory": "ICSA-15-013-04",
        "discovery": "EXTERNAL"
      },
      "title": "GE Multilink Uncontrolled Resource Consumption",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-5418",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04"
            },
            {
              "name": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-5418",
    "datePublished": "2015-01-17T02:00:00",
    "dateReserved": "2014-08-22T00:00:00",
    "dateUpdated": "2025-11-04T23:30:32.557Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2014-5419 (GCVE-0-2014-5419)

Vulnerability from cvelistv5 – Published: 2015-01-17 02:00 – Updated: 2025-11-04 23:32
VLAI?
Summary
GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier use the same RSA private key across different customers' installations, which makes it easier for remote attackers to obtain the cleartext content of network traffic by reading this key from a firmware image and then sniffing the network.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
GE Multilink ML800/1200/1600/2400 Affected: 0 , ≤ 4.2.1 (custom)
Create a notification for this product.
Credits
Eireann Leverett of IOActive
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T11:41:49.264Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Multilink ML800/1200/1600/2400",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "4.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ML810/3000/3100 series switch",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "5.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Eireann Leverett of IOActive"
        }
      ],
      "datePublic": "2015-01-13T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\nGE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier use the same RSA private key across different customers\u0027 installations, which makes it easier for remote attackers to obtain the cleartext content of network traffic by reading this key from a firmware image and then sniffing the network.\n\n\u003c/p\u003e"
            }
          ],
          "value": "GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier use the same RSA private key across different customers\u0027 installations, which makes it easier for remote attackers to obtain the cleartext content of network traffic by reading this key from a firmware image and then sniffing the network."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-04T23:32:07.026Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-013-04a"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2015/icsa-15-013-04a.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eGE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.gedigitalenergy.com\"\u003ehttp://www.gedigitalenergy.com\u003c/a\u003e. This firmware is also available through \nthe EnerVista Launchpad device management tool.\u003c/p\u003e\n\u003cp\u003eGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\u003c/p\u003e\n\u003cp\u003ePlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\"\u003ehttps://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "GE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n http://www.gedigitalenergy.com . This firmware is also available through \nthe EnerVista Launchpad device management tool.\n\n\nGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\n\n\nPlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\n\n\n https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf"
        }
      ],
      "source": {
        "advisory": "ICSA-15-013-04",
        "discovery": "EXTERNAL"
      },
      "title": "GE Multilink Use of Hard-coded Cryptographic Key",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-5418",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04"
            },
            {
              "name": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-5419",
    "datePublished": "2015-01-17T02:00:00",
    "dateReserved": "2014-08-22T00:00:00",
    "dateUpdated": "2025-11-04T23:32:07.026Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2015-3976 (GCVE-0-2015-3976)

Vulnerability from nvd – Published: 2017-08-28 15:00 – Updated: 2025-11-04 23:33
VLAI?
Summary
Cross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
GE Multilink ML800/1200/1600/2400 Affected: 0 , ≤ 4.2.1 (custom)
Create a notification for this product.
Credits
Eireann Leverett of IOActive
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T06:04:02.453Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04A"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Multilink ML800/1200/1600/2400",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "4.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ML810/3000/3100 series switch",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "5.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Eireann Leverett of IOActive"
        }
      ],
      "datePublic": "2015-01-13T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\n\nCross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier.\n\n\u003c/p\u003e"
            }
          ],
          "value": "Cross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "confidentialityImpact": "NONE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:C/A:N",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-04T23:33:49.742Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-013-04a"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2015/icsa-15-013-04a.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eGE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.gedigitalenergy.com\"\u003ehttp://www.gedigitalenergy.com\u003c/a\u003e. This firmware is also available through \nthe EnerVista Launchpad device management tool.\u003c/p\u003e\n\u003cp\u003eGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\u003c/p\u003e\n\u003cp\u003ePlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\"\u003ehttps://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "GE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n http://www.gedigitalenergy.com . This firmware is also available through \nthe EnerVista Launchpad device management tool.\n\n\nGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\n\n\nPlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\n\n\n https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf"
        }
      ],
      "source": {
        "advisory": "ICSA-15-013-04",
        "discovery": "EXTERNAL"
      },
      "title": "GE Multilink Cross-site Scripting",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-5418",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04"
            },
            {
              "name": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2015-3976",
    "datePublished": "2017-08-28T15:00:00",
    "dateReserved": "2015-05-12T00:00:00",
    "dateUpdated": "2025-11-04T23:33:49.742Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2014-5418 (GCVE-0-2014-5418)

Vulnerability from nvd – Published: 2015-01-17 02:00 – Updated: 2025-11-04 23:30
VLAI?
Summary
GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
GE Multilink ML800/1200/1600/2400 Affected: 0 , ≤ 4.2.1 (custom)
Create a notification for this product.
Credits
Eireann Leverett of IOActive
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T11:41:49.173Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Multilink ML800/1200/1600/2400",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "4.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ML810/3000/3100 series switch",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "5.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Eireann Leverett of IOActive"
        }
      ],
      "datePublic": "2015-01-13T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eGE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets.\u003c/p\u003e"
            }
          ],
          "value": "GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5,
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-04T23:30:32.557Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-013-04a"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2015/icsa-15-013-04a.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eGE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.gedigitalenergy.com\"\u003ehttp://www.gedigitalenergy.com\u003c/a\u003e. This firmware is also available through \nthe EnerVista Launchpad device management tool.\u003c/p\u003e\n\u003cp\u003eGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\u003c/p\u003e\n\u003cp\u003ePlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\"\u003ehttps://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "GE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n http://www.gedigitalenergy.com . This firmware is also available through \nthe EnerVista Launchpad device management tool.\n\n\nGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\n\n\nPlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\n\n\n https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf"
        }
      ],
      "source": {
        "advisory": "ICSA-15-013-04",
        "discovery": "EXTERNAL"
      },
      "title": "GE Multilink Uncontrolled Resource Consumption",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-5418",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04"
            },
            {
              "name": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-5418",
    "datePublished": "2015-01-17T02:00:00",
    "dateReserved": "2014-08-22T00:00:00",
    "dateUpdated": "2025-11-04T23:30:32.557Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2014-5419 (GCVE-0-2014-5419)

Vulnerability from nvd – Published: 2015-01-17 02:00 – Updated: 2025-11-04 23:32
VLAI?
Summary
GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier use the same RSA private key across different customers' installations, which makes it easier for remote attackers to obtain the cleartext content of network traffic by reading this key from a firmware image and then sniffing the network.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
GE Multilink ML800/1200/1600/2400 Affected: 0 , ≤ 4.2.1 (custom)
Create a notification for this product.
Credits
Eireann Leverett of IOActive
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T11:41:49.264Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Multilink ML800/1200/1600/2400",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "4.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ML810/3000/3100 series switch",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "5.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Eireann Leverett of IOActive"
        }
      ],
      "datePublic": "2015-01-13T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\nGE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier use the same RSA private key across different customers\u0027 installations, which makes it easier for remote attackers to obtain the cleartext content of network traffic by reading this key from a firmware image and then sniffing the network.\n\n\u003c/p\u003e"
            }
          ],
          "value": "GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier use the same RSA private key across different customers\u0027 installations, which makes it easier for remote attackers to obtain the cleartext content of network traffic by reading this key from a firmware image and then sniffing the network."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-04T23:32:07.026Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-013-04a"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2015/icsa-15-013-04a.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eGE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.gedigitalenergy.com\"\u003ehttp://www.gedigitalenergy.com\u003c/a\u003e. This firmware is also available through \nthe EnerVista Launchpad device management tool.\u003c/p\u003e\n\u003cp\u003eGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\u003c/p\u003e\n\u003cp\u003ePlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\"\u003ehttps://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "GE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n http://www.gedigitalenergy.com . This firmware is also available through \nthe EnerVista Launchpad device management tool.\n\n\nGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\n\n\nPlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\n\n\n https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf"
        }
      ],
      "source": {
        "advisory": "ICSA-15-013-04",
        "discovery": "EXTERNAL"
      },
      "title": "GE Multilink Use of Hard-coded Cryptographic Key",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-5418",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04"
            },
            {
              "name": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-5419",
    "datePublished": "2015-01-17T02:00:00",
    "dateReserved": "2014-08-22T00:00:00",
    "dateUpdated": "2025-11-04T23:32:07.026Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}