CVE-2015-3976 (GCVE-0-2015-3976)
Vulnerability from cvelistv5 – Published: 2017-08-28 15:00 – Updated: 2025-11-04 23:33
VLAI?
Title
GE Multilink Cross-site Scripting
Summary
Cross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| GE | Multilink ML800/1200/1600/2400 |
Affected:
0 , ≤ 4.2.1
(custom)
|
|||||||
|
|||||||||
Credits
Eireann Leverett of IOActive
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T06:04:02.453Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04A"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Multilink ML800/1200/1600/2400",
"vendor": "GE",
"versions": [
{
"lessThanOrEqual": "4.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ML810/3000/3100 series switch",
"vendor": "GE",
"versions": [
{
"lessThanOrEqual": "5.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Eireann Leverett of IOActive"
}
],
"datePublic": "2015-01-13T07:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\n\nCross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier.\n\n\u003c/p\u003e"
}
],
"value": "Cross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier."
}
],
"metrics": [
{
"cvssV2_0": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 6.8,
"confidentialityImpact": "NONE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:C/A:N",
"version": "2.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-04T23:33:49.742Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-013-04a"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2015/icsa-15-013-04a.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eGE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.gedigitalenergy.com\"\u003ehttp://www.gedigitalenergy.com\u003c/a\u003e. This firmware is also available through \nthe EnerVista Launchpad device management tool.\u003c/p\u003e\n\u003cp\u003eGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\u003c/p\u003e\n\u003cp\u003ePlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\"\u003ehttps://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "GE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n http://www.gedigitalenergy.com . This firmware is also available through \nthe EnerVista Launchpad device management tool.\n\n\nGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\n\n\nPlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\n\n\n https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf"
}
],
"source": {
"advisory": "ICSA-15-013-04",
"discovery": "EXTERNAL"
},
"title": "GE Multilink Cross-site Scripting",
"x_generator": {
"engine": "Vulnogram 0.5.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2014-5418",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04"
},
{
"name": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf",
"refsource": "CONFIRM",
"url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2015-3976",
"datePublished": "2017-08-28T15:00:00",
"dateReserved": "2015-05-12T00:00:00",
"dateUpdated": "2025-11-04T23:33:49.742Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ge:multilink_ml810_firmware:5.2.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"26502C62-8445-45C8-B099-02513595D002\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ge:multilink_ml810:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"81DC26E5-D3D7-41C6-B654-B06FA0461451\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ge:multilink_ml3000_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"5.2.0\", \"matchCriteriaId\": \"F8CCA289-8E58-41E9-9AD3-860A6B373EE3\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ge:multilink_ml3000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7EE40202-1D8F-406E-8281-B67DCF5E8501\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ge:multilink_ml3100_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"5.2.0\", \"matchCriteriaId\": \"339C1069-C126-4840-92DC-0DBE17FD764C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ge:multilink_ml3100:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D72F9922-A473-4076-91E3-CF3899C179D7\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ge:multilink_ml800_firmware:4.2.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"83DE9D2A-3A96-4051-9C69-0B0C9EA26EE4\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ge:multilink_ml800:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9A00E85C-1B21-43F7-8323-F759216BFB90\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ge:multilink_ml1200_firmware:4.2.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D8A95DAC-C62C-451A-9613-123FECFB9627\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ge:multilink_ml1200:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1179F179-510A-4A97-8365-B81C0E0FC605\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ge:multilink_ml1600_firmware:4.2.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"256CB390-1BAB-41E3-89AA-98BA88114D84\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ge:multilink_ml1600:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"620703E4-1D78-44CB-B353-517A8AB2A815\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ge:multilink_ml2400_firmware:4.2.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"EB917F77-2933-4877-A8A2-C6364D6DCE0A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ge:multilink_ml2400:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"426A283A-540C-43F2-8397-52668BADDEB8\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Cross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier.\"}, {\"lang\": \"es\", \"value\": \"Existe una vulnerabilidad de tipo Cross-Site Scripting (XSS) en GE Multilink ML810/3000/3100 series switch 5.2.0 y anteriores y en GE Multilink ML800/1200/1600/2400 4.2.1 y anteriores.\"}]",
"id": "CVE-2015-3976",
"lastModified": "2024-11-21T02:30:11.200",
"metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 5.4, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.3, \"impactScore\": 2.7}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:S/C:N/I:P/A:N\", \"baseScore\": 3.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"LOW\", \"exploitabilityScore\": 6.8, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
"published": "2017-08-28T15:29:01.453",
"references": "[{\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04A\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04A\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}]",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2015-3976\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2017-08-28T15:29:01.453\",\"lastModified\":\"2025-11-05T00:15:34.387\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Cross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de tipo Cross-Site Scripting (XSS) en GE Multilink ML810/3000/3100 series switch 5.2.0 y anteriores y en GE Multilink ML800/1200/1600/2400 4.2.1 y anteriores.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:N/I:C/A:N\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:N/I:P/A:N\",\"baseScore\":3.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":6.8,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ge:multilink_ml810_firmware:5.2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"26502C62-8445-45C8-B099-02513595D002\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ge:multilink_ml810:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"81DC26E5-D3D7-41C6-B654-B06FA0461451\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ge:multilink_ml3000_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"5.2.0\",\"matchCriteriaId\":\"F8CCA289-8E58-41E9-9AD3-860A6B373EE3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ge:multilink_ml3000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7EE40202-1D8F-406E-8281-B67DCF5E8501\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ge:multilink_ml3100_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"5.2.0\",\"matchCriteriaId\":\"339C1069-C126-4840-92DC-0DBE17FD764C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ge:multilink_ml3100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D72F9922-A473-4076-91E3-CF3899C179D7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ge:multilink_ml800_firmware:4.2.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"83DE9D2A-3A96-4051-9C69-0B0C9EA26EE4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ge:multilink_ml800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9A00E85C-1B21-43F7-8323-F759216BFB90\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ge:multilink_ml1200_firmware:4.2.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D8A95DAC-C62C-451A-9613-123FECFB9627\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ge:multilink_ml1200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1179F179-510A-4A97-8365-B81C0E0FC605\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ge:multilink_ml1600_firmware:4.2.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"256CB390-1BAB-41E3-89AA-98BA88114D84\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ge:multilink_ml1600:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"620703E4-1D78-44CB-B353-517A8AB2A815\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ge:multilink_ml2400_firmware:4.2.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EB917F77-2933-4877-A8A2-C6364D6DCE0A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ge:multilink_ml2400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"426A283A-540C-43F2-8397-52668BADDEB8\"}]}]}],\"references\":[{\"url\":\"http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2015/icsa-15-013-04a.json\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-15-013-04a\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04A\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…