FKIE_CVE-2023-28084
Vulnerability from fkie_nvd - Published: 2023-04-25 20:15 - Updated: 2025-02-03 17:15
Severity ?
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Summary
HPE OneView and HPE OneView Global Dashboard appliance dumps may expose authentication tokens
References
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:hp:oneview:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FBAAD7B8-CB8C-4F50-8A30-0B2CF5199B8F",
"versionEndExcluding": "6.60.04",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hp:oneview:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CCD692B5-5224-4D65-B5F6-9B1B4EF5B227",
"versionEndExcluding": "8.2",
"versionStartIncluding": "7.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hpe:oneview_global_dashboard:*:*:*:*:*:*:*:*",
"matchCriteriaId": "458F8B2A-D560-4497-9DD0-1C654B28B991",
"versionEndExcluding": "2.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "HPE OneView and HPE OneView Global Dashboard appliance dumps may expose authentication tokens"
}
],
"id": "CVE-2023-28084",
"lastModified": "2025-02-03T17:15:12.930",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2023-04-25T20:15:10.067",
"references": [
{
"source": "security-alert@hpe.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbgn04468en_us"
},
{
"source": "security-alert@hpe.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbgn04469en_us"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbgn04468en_us"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbgn04469en_us"
}
],
"sourceIdentifier": "security-alert@hpe.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-522"
}
],
"source": "security-alert@hpe.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-522"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-522"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-28085
Vulnerability from fkie_nvd - Published: 2023-04-14 15:15 - Updated: 2025-02-06 20:15
Severity ?
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Summary
An HPE OneView Global Dashboard (OVGD) appliance dump may expose OVGD user account credentials
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| hpe | oneview_global_dashboard | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:hpe:oneview_global_dashboard:*:*:*:*:*:*:*:*",
"matchCriteriaId": "458F8B2A-D560-4497-9DD0-1C654B28B991",
"versionEndExcluding": "2.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An HPE OneView Global Dashboard (OVGD) appliance dump may expose OVGD user account credentials"
}
],
"id": "CVE-2023-28085",
"lastModified": "2025-02-06T20:15:38.483",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2023-04-14T15:15:07.523",
"references": [
{
"source": "security-alert@hpe.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbgn04468en_us"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbgn04468en_us"
}
],
"sourceIdentifier": "security-alert@hpe.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2022-37927
Vulnerability from fkie_nvd - Published: 2022-12-12 13:15 - Updated: 2025-05-01 16:15
Severity ?
6.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
6.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
6.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Summary
URL Redirection to Untrusted Site ('Open Redirect') vulnerability in Hewlett Packard Enterprise HPE OneView Global Dashboard (OVGD).
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| hpe | oneview_global_dashboard | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:hpe:oneview_global_dashboard:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F0BABA92-3BA2-41A4-9997-2A8F4CAEC254",
"versionEndExcluding": "2.7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "URL Redirection to Untrusted Site (\u0027Open Redirect\u0027) vulnerability in Hewlett Packard Enterprise HPE OneView Global Dashboard (OVGD).\n\n"
},
{
"lang": "es",
"value": "Vulnerabilidad de redirecci\u00f3n de URL a un sitio que no es de confianza (\"Open Redirect\") en Hewlett Packard Enterprise HPE OneView Global Dashboard (OVGD)."
}
],
"id": "CVE-2022-37927",
"lastModified": "2025-05-01T16:15:22.770",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "security-alert@hpe.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-12-12T13:15:14.113",
"references": [
{
"source": "security-alert@hpe.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbhf04370en_us"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbhf04370en_us"
}
],
"sourceIdentifier": "security-alert@hpe.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-601"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-601"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2021-29217
Vulnerability from fkie_nvd - Published: 2022-02-24 22:15 - Updated: 2024-11-21 06:00
Severity ?
Summary
A remote URL redirection vulnerability was discovered in HPE OneView Global Dashboard version(s): Prior to 2.5. HPE has provided a software update to resolve this vulnerability in HPE OneView Global Dashboard.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| hpe | oneview_global_dashboard | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:hpe:oneview_global_dashboard:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F6982893-D5A7-4306-AED8-549B2FE60DA5",
"versionEndExcluding": "2.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A remote URL redirection vulnerability was discovered in HPE OneView Global Dashboard version(s): Prior to 2.5. HPE has provided a software update to resolve this vulnerability in HPE OneView Global Dashboard."
},
{
"lang": "es",
"value": "Se ha detectado una vulnerabilidad de redireccionamiento de URL remota en HPE OneView Global Dashboard versiones: Anteriores a 2.5. HPE ha proporcionado una actualizaci\u00f3n de software para resolver esta vulnerabilidad en HPE OneView Global Dashboard"
}
],
"id": "CVE-2021-29217",
"lastModified": "2024-11-21T06:00:50.780",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 4.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-02-24T22:15:08.173",
"references": [
{
"source": "security-alert@hpe.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us"
}
],
"sourceIdentifier": "security-alert@hpe.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-601"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-29216
Vulnerability from fkie_nvd - Published: 2022-02-24 22:15 - Updated: 2024-11-21 06:00
Severity ?
Summary
A remote cross-site scripting vulnerability was discovered in HPE OneView Global Dashboard version(s): Prior to 2.5. HPE has provided a software update to resolve this vulnerability in HPE OneView Global Dashboard.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| hpe | oneview_global_dashboard | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:hpe:oneview_global_dashboard:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F6982893-D5A7-4306-AED8-549B2FE60DA5",
"versionEndExcluding": "2.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A remote cross-site scripting vulnerability was discovered in HPE OneView Global Dashboard version(s): Prior to 2.5. HPE has provided a software update to resolve this vulnerability in HPE OneView Global Dashboard."
},
{
"lang": "es",
"value": "Se ha detectado una vulnerabilidad de tipo cross-site scripting remoto en HPE OneView Global Dashboard versiones: Anteriores a 2.5. HPE ha proporcionado una actualizaci\u00f3n de software para resolver esta vulnerabilidad en HPE OneView Global Dashboard"
}
],
"id": "CVE-2021-29216",
"lastModified": "2024-11-21T06:00:50.667",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-02-24T22:15:08.127",
"references": [
{
"source": "security-alert@hpe.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us"
}
],
"sourceIdentifier": "security-alert@hpe.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-26585
Vulnerability from fkie_nvd - Published: 2021-06-24 12:15 - Updated: 2024-11-21 05:56
Severity ?
Summary
A potential vulnerability has been identified in HPE OneView Global Dashboard release 2.31 which could lead to a local disclosure of privileged information. HPE has provided an update to OneView Global Dashboard. The issue is resolved in 2.32.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| hpe | oneview_global_dashboard | 2.31 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:hpe:oneview_global_dashboard:2.31:*:*:*:*:*:*:*",
"matchCriteriaId": "AF159F7C-30AC-4053-BE9F-08FBF036149B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A potential vulnerability has been identified in HPE OneView Global Dashboard release 2.31 which could lead to a local disclosure of privileged information. HPE has provided an update to OneView Global Dashboard. The issue is resolved in 2.32."
},
{
"lang": "es",
"value": "Una vulnerabilidad potencial ha sido identificada en HPE OneView Global Dashboard versi\u00f3n 2.31, que podr\u00eda conllevar a una divulgaci\u00f3n de informaci\u00f3n local privilegiada. HPE ha proporcionado una actualizaci\u00f3n de OneView Global Dashboard. El problema se ha resuelto en la versi\u00f3n 2.32"
}
],
"id": "CVE-2021-26585",
"lastModified": "2024-11-21T05:56:32.043",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-06-24T12:15:08.043",
"references": [
{
"source": "security-alert@hpe.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04162en_us"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04162en_us"
}
],
"sourceIdentifier": "security-alert@hpe.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2023-28084 (GCVE-0-2023-28084)
Vulnerability from cvelistv5 – Published: 2023-04-25 19:00 – Updated: 2025-02-03 17:00
VLAI?
Title
HPE OneView and HPE OneView Global Dashboard appliance dumps may expose authentication tokens
Summary
HPE OneView and HPE OneView Global Dashboard appliance dumps may expose authentication tokens
Severity ?
5.5 (Medium)
CWE
- CWE-522 - Insufficiently Protected Credentials
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Hewlett Packard Enterprise | HPE OneView |
Affected:
0 , ≤ 8.2
(custom)
Affected: 0 , < 6.60.04 (custom) |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:30:24.061Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbgn04468en_us"
},
{
"tags": [
"x_transferred"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbgn04469en_us"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-28084",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-03T16:58:51.561128Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522 Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-03T17:00:17.458Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "HPE OneView",
"vendor": "Hewlett Packard Enterprise",
"versions": [
{
"lessThanOrEqual": "8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "6.60.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "HPE OneView Global Dashboard",
"vendor": "Hewlett Packard Enterprise",
"versions": [
{
"lessThan": "2.72",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "HPE OneView and HPE OneView Global Dashboard appliance dumps may expose authentication tokens"
}
],
"value": "HPE OneView and HPE OneView Global Dashboard appliance dumps may expose authentication tokens"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522 Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-25T19:00:24.125Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbgn04468en_us"
},
{
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbgn04469en_us"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "HPE OneView and HPE OneView Global Dashboard appliance dumps may expose authentication tokens",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2023-28084",
"datePublished": "2023-04-25T19:00:14.252Z",
"dateReserved": "2023-03-10T14:47:44.211Z",
"dateUpdated": "2025-02-03T17:00:17.458Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-28085 (GCVE-0-2023-28085)
Vulnerability from cvelistv5 – Published: 2023-04-14 14:22 – Updated: 2025-02-06 19:27
VLAI?
Summary
An HPE OneView Global Dashboard (OVGD) appliance dump may expose OVGD user account credentials
Severity ?
5.5 (Medium)
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise (HPE) | HPE OneView Global Dashboard |
Affected:
0 , ≤ 2.72
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:30:23.949Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbgn04468en_us"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-28085",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-06T19:24:58.691541Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-noinfo Not enough information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-06T19:27:08.204Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HPE OneView Global Dashboard",
"vendor": "Hewlett Packard Enterprise (HPE)",
"versions": [
{
"lessThanOrEqual": "2.72",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An HPE OneView Global Dashboard (OVGD) appliance dump may expose OVGD user account credentials"
}
],
"providerMetadata": {
"dateUpdated": "2023-04-14T14:22:24.896Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbgn04468en_us"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2023-28085",
"datePublished": "2023-04-14T14:22:24.896Z",
"dateReserved": "2023-03-10T14:47:44.212Z",
"dateUpdated": "2025-02-06T19:27:08.204Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-37927 (GCVE-0-2022-37927)
Vulnerability from cvelistv5 – Published: 2022-11-03 14:53 – Updated: 2025-05-01 15:40
VLAI?
Summary
URL Redirection to Untrusted Site ('Open Redirect') vulnerability in Hewlett Packard Enterprise HPE OneView Global Dashboard (OVGD).
Severity ?
6.1 (Medium)
CWE
- n/a
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise (HPE) | HPE OneView Global Dashboard (OVGD) |
Affected:
Prior to 2.7
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:37:42.561Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbhf04370en_us"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-37927",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T15:40:26.064191Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-601",
"description": "CWE-601 URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T15:40:45.496Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "HPE OneView Global Dashboard (OVGD)",
"vendor": "Hewlett Packard Enterprise (HPE)",
"versions": [
{
"status": "affected",
"version": "Prior to 2.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eURL Redirection to Untrusted Site (\u0027Open Redirect\u0027) vulnerability in Hewlett Packard Enterprise HPE OneView Global Dashboard (OVGD).\u003c/p\u003e"
}
],
"value": "URL Redirection to Untrusted Site (\u0027Open Redirect\u0027) vulnerability in Hewlett Packard Enterprise HPE OneView Global Dashboard (OVGD).\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-12T12:11:04.548Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbhf04370en_us"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2022-37927",
"datePublished": "2022-11-03T14:53:01.153Z",
"dateReserved": "2022-08-08T18:49:44.384Z",
"dateUpdated": "2025-05-01T15:40:45.496Z",
"requesterUserId": "6707ad87-4508-4473-b324-feac48da5e14",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-29217 (GCVE-0-2021-29217)
Vulnerability from cvelistv5 – Published: 2022-02-24 21:04 – Updated: 2024-08-03 22:02
VLAI?
Summary
A remote URL redirection vulnerability was discovered in HPE OneView Global Dashboard version(s): Prior to 2.5. HPE has provided a software update to resolve this vulnerability in HPE OneView Global Dashboard.
Severity ?
No CVSS data available.
CWE
- remote URL redirection
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | HPE OneView Global Dashboard |
Affected:
Prior to 2.5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T22:02:51.677Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE OneView Global Dashboard",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Prior to 2.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A remote URL redirection vulnerability was discovered in HPE OneView Global Dashboard version(s): Prior to 2.5. HPE has provided a software update to resolve this vulnerability in HPE OneView Global Dashboard."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote URL redirection",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-24T21:04:45",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2021-29217",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE OneView Global Dashboard",
"version": {
"version_data": [
{
"version_value": "Prior to 2.5"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A remote URL redirection vulnerability was discovered in HPE OneView Global Dashboard version(s): Prior to 2.5. HPE has provided a software update to resolve this vulnerability in HPE OneView Global Dashboard."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote URL redirection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us",
"refsource": "MISC",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2021-29217",
"datePublished": "2022-02-24T21:04:45",
"dateReserved": "2021-03-25T00:00:00",
"dateUpdated": "2024-08-03T22:02:51.677Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-29216 (GCVE-0-2021-29216)
Vulnerability from cvelistv5 – Published: 2022-02-24 21:04 – Updated: 2024-08-03 22:02
VLAI?
Summary
A remote cross-site scripting vulnerability was discovered in HPE OneView Global Dashboard version(s): Prior to 2.5. HPE has provided a software update to resolve this vulnerability in HPE OneView Global Dashboard.
Severity ?
No CVSS data available.
CWE
- remote cross-site scripting
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | HPE OneView Global Dashboard |
Affected:
Prior to 2.5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T22:02:51.176Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE OneView Global Dashboard",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Prior to 2.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A remote cross-site scripting vulnerability was discovered in HPE OneView Global Dashboard version(s): Prior to 2.5. HPE has provided a software update to resolve this vulnerability in HPE OneView Global Dashboard."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote cross-site scripting",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-24T21:04:06",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2021-29216",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE OneView Global Dashboard",
"version": {
"version_data": [
{
"version_value": "Prior to 2.5"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A remote cross-site scripting vulnerability was discovered in HPE OneView Global Dashboard version(s): Prior to 2.5. HPE has provided a software update to resolve this vulnerability in HPE OneView Global Dashboard."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote cross-site scripting"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us",
"refsource": "MISC",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2021-29216",
"datePublished": "2022-02-24T21:04:06",
"dateReserved": "2021-03-25T00:00:00",
"dateUpdated": "2024-08-03T22:02:51.176Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-26585 (GCVE-0-2021-26585)
Vulnerability from cvelistv5 – Published: 2021-06-24 11:02 – Updated: 2024-08-03 20:26
VLAI?
Summary
A potential vulnerability has been identified in HPE OneView Global Dashboard release 2.31 which could lead to a local disclosure of privileged information. HPE has provided an update to OneView Global Dashboard. The issue is resolved in 2.32.
Severity ?
No CVSS data available.
CWE
- local disclosure of privileged information
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | HPE OneView Global Dashboard |
Affected:
only 2.31
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:26:25.544Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04162en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE OneView Global Dashboard",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "only 2.31"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A potential vulnerability has been identified in HPE OneView Global Dashboard release 2.31 which could lead to a local disclosure of privileged information. HPE has provided an update to OneView Global Dashboard. The issue is resolved in 2.32."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "local disclosure of privileged information",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-24T11:02:24",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04162en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2021-26585",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE OneView Global Dashboard",
"version": {
"version_data": [
{
"version_value": "only 2.31"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A potential vulnerability has been identified in HPE OneView Global Dashboard release 2.31 which could lead to a local disclosure of privileged information. HPE has provided an update to OneView Global Dashboard. The issue is resolved in 2.32."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "local disclosure of privileged information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04162en_us",
"refsource": "MISC",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04162en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2021-26585",
"datePublished": "2021-06-24T11:02:24",
"dateReserved": "2021-02-02T00:00:00",
"dateUpdated": "2024-08-03T20:26:25.544Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-28084 (GCVE-0-2023-28084)
Vulnerability from nvd – Published: 2023-04-25 19:00 – Updated: 2025-02-03 17:00
VLAI?
Title
HPE OneView and HPE OneView Global Dashboard appliance dumps may expose authentication tokens
Summary
HPE OneView and HPE OneView Global Dashboard appliance dumps may expose authentication tokens
Severity ?
5.5 (Medium)
CWE
- CWE-522 - Insufficiently Protected Credentials
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Hewlett Packard Enterprise | HPE OneView |
Affected:
0 , ≤ 8.2
(custom)
Affected: 0 , < 6.60.04 (custom) |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:30:24.061Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbgn04468en_us"
},
{
"tags": [
"x_transferred"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbgn04469en_us"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-28084",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-03T16:58:51.561128Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522 Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-03T17:00:17.458Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "HPE OneView",
"vendor": "Hewlett Packard Enterprise",
"versions": [
{
"lessThanOrEqual": "8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "6.60.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "HPE OneView Global Dashboard",
"vendor": "Hewlett Packard Enterprise",
"versions": [
{
"lessThan": "2.72",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "HPE OneView and HPE OneView Global Dashboard appliance dumps may expose authentication tokens"
}
],
"value": "HPE OneView and HPE OneView Global Dashboard appliance dumps may expose authentication tokens"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522 Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-25T19:00:24.125Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbgn04468en_us"
},
{
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbgn04469en_us"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "HPE OneView and HPE OneView Global Dashboard appliance dumps may expose authentication tokens",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2023-28084",
"datePublished": "2023-04-25T19:00:14.252Z",
"dateReserved": "2023-03-10T14:47:44.211Z",
"dateUpdated": "2025-02-03T17:00:17.458Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-28085 (GCVE-0-2023-28085)
Vulnerability from nvd – Published: 2023-04-14 14:22 – Updated: 2025-02-06 19:27
VLAI?
Summary
An HPE OneView Global Dashboard (OVGD) appliance dump may expose OVGD user account credentials
Severity ?
5.5 (Medium)
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise (HPE) | HPE OneView Global Dashboard |
Affected:
0 , ≤ 2.72
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:30:23.949Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbgn04468en_us"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-28085",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-06T19:24:58.691541Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-noinfo Not enough information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-06T19:27:08.204Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HPE OneView Global Dashboard",
"vendor": "Hewlett Packard Enterprise (HPE)",
"versions": [
{
"lessThanOrEqual": "2.72",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An HPE OneView Global Dashboard (OVGD) appliance dump may expose OVGD user account credentials"
}
],
"providerMetadata": {
"dateUpdated": "2023-04-14T14:22:24.896Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbgn04468en_us"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2023-28085",
"datePublished": "2023-04-14T14:22:24.896Z",
"dateReserved": "2023-03-10T14:47:44.212Z",
"dateUpdated": "2025-02-06T19:27:08.204Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-37927 (GCVE-0-2022-37927)
Vulnerability from nvd – Published: 2022-11-03 14:53 – Updated: 2025-05-01 15:40
VLAI?
Summary
URL Redirection to Untrusted Site ('Open Redirect') vulnerability in Hewlett Packard Enterprise HPE OneView Global Dashboard (OVGD).
Severity ?
6.1 (Medium)
CWE
- n/a
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise (HPE) | HPE OneView Global Dashboard (OVGD) |
Affected:
Prior to 2.7
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:37:42.561Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbhf04370en_us"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-37927",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T15:40:26.064191Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-601",
"description": "CWE-601 URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T15:40:45.496Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "HPE OneView Global Dashboard (OVGD)",
"vendor": "Hewlett Packard Enterprise (HPE)",
"versions": [
{
"status": "affected",
"version": "Prior to 2.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eURL Redirection to Untrusted Site (\u0027Open Redirect\u0027) vulnerability in Hewlett Packard Enterprise HPE OneView Global Dashboard (OVGD).\u003c/p\u003e"
}
],
"value": "URL Redirection to Untrusted Site (\u0027Open Redirect\u0027) vulnerability in Hewlett Packard Enterprise HPE OneView Global Dashboard (OVGD).\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-12T12:11:04.548Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbhf04370en_us"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2022-37927",
"datePublished": "2022-11-03T14:53:01.153Z",
"dateReserved": "2022-08-08T18:49:44.384Z",
"dateUpdated": "2025-05-01T15:40:45.496Z",
"requesterUserId": "6707ad87-4508-4473-b324-feac48da5e14",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-29217 (GCVE-0-2021-29217)
Vulnerability from nvd – Published: 2022-02-24 21:04 – Updated: 2024-08-03 22:02
VLAI?
Summary
A remote URL redirection vulnerability was discovered in HPE OneView Global Dashboard version(s): Prior to 2.5. HPE has provided a software update to resolve this vulnerability in HPE OneView Global Dashboard.
Severity ?
No CVSS data available.
CWE
- remote URL redirection
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | HPE OneView Global Dashboard |
Affected:
Prior to 2.5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T22:02:51.677Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE OneView Global Dashboard",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Prior to 2.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A remote URL redirection vulnerability was discovered in HPE OneView Global Dashboard version(s): Prior to 2.5. HPE has provided a software update to resolve this vulnerability in HPE OneView Global Dashboard."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote URL redirection",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-24T21:04:45",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2021-29217",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE OneView Global Dashboard",
"version": {
"version_data": [
{
"version_value": "Prior to 2.5"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A remote URL redirection vulnerability was discovered in HPE OneView Global Dashboard version(s): Prior to 2.5. HPE has provided a software update to resolve this vulnerability in HPE OneView Global Dashboard."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote URL redirection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us",
"refsource": "MISC",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2021-29217",
"datePublished": "2022-02-24T21:04:45",
"dateReserved": "2021-03-25T00:00:00",
"dateUpdated": "2024-08-03T22:02:51.677Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-29216 (GCVE-0-2021-29216)
Vulnerability from nvd – Published: 2022-02-24 21:04 – Updated: 2024-08-03 22:02
VLAI?
Summary
A remote cross-site scripting vulnerability was discovered in HPE OneView Global Dashboard version(s): Prior to 2.5. HPE has provided a software update to resolve this vulnerability in HPE OneView Global Dashboard.
Severity ?
No CVSS data available.
CWE
- remote cross-site scripting
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | HPE OneView Global Dashboard |
Affected:
Prior to 2.5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T22:02:51.176Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE OneView Global Dashboard",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Prior to 2.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A remote cross-site scripting vulnerability was discovered in HPE OneView Global Dashboard version(s): Prior to 2.5. HPE has provided a software update to resolve this vulnerability in HPE OneView Global Dashboard."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote cross-site scripting",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-24T21:04:06",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2021-29216",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE OneView Global Dashboard",
"version": {
"version_data": [
{
"version_value": "Prior to 2.5"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A remote cross-site scripting vulnerability was discovered in HPE OneView Global Dashboard version(s): Prior to 2.5. HPE has provided a software update to resolve this vulnerability in HPE OneView Global Dashboard."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote cross-site scripting"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us",
"refsource": "MISC",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04228en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2021-29216",
"datePublished": "2022-02-24T21:04:06",
"dateReserved": "2021-03-25T00:00:00",
"dateUpdated": "2024-08-03T22:02:51.176Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-26585 (GCVE-0-2021-26585)
Vulnerability from nvd – Published: 2021-06-24 11:02 – Updated: 2024-08-03 20:26
VLAI?
Summary
A potential vulnerability has been identified in HPE OneView Global Dashboard release 2.31 which could lead to a local disclosure of privileged information. HPE has provided an update to OneView Global Dashboard. The issue is resolved in 2.32.
Severity ?
No CVSS data available.
CWE
- local disclosure of privileged information
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | HPE OneView Global Dashboard |
Affected:
only 2.31
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:26:25.544Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04162en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE OneView Global Dashboard",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "only 2.31"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A potential vulnerability has been identified in HPE OneView Global Dashboard release 2.31 which could lead to a local disclosure of privileged information. HPE has provided an update to OneView Global Dashboard. The issue is resolved in 2.32."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "local disclosure of privileged information",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-24T11:02:24",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04162en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2021-26585",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE OneView Global Dashboard",
"version": {
"version_data": [
{
"version_value": "only 2.31"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A potential vulnerability has been identified in HPE OneView Global Dashboard release 2.31 which could lead to a local disclosure of privileged information. HPE has provided an update to OneView Global Dashboard. The issue is resolved in 2.32."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "local disclosure of privileged information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04162en_us",
"refsource": "MISC",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04162en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2021-26585",
"datePublished": "2021-06-24T11:02:24",
"dateReserved": "2021-02-02T00:00:00",
"dateUpdated": "2024-08-03T20:26:25.544Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}