All the vulnerabilites related to mitsubishielectric - r32psfcpu_firmware
cve-2020-5668
Vulnerability from cvelistv5
Published
2020-11-20 03:30
Modified
2024-08-04 08:39
Severity ?
EPSS score ?
Summary
Uncontrolled resource consumption vulnerability in MELSEC iQ-R Series modules (R00/01/02CPU firmware version '19' and earlier, R04/08/16/32/120 (EN) CPU firmware version '51' and earlier, R08/16/32/120SFCPU firmware version '22' and earlier, R08/16/32/120PCPU firmware version '25' and earlier, R08/16/32/120PSFCPU firmware version '06' and earlier, RJ71EN71 firmware version '47' and earlier, RJ71GF11-T2 firmware version '47' and earlier, RJ72GF15-T2 firmware version '07' and earlier, RJ71GP21-SX firmware version '47' and earlier, RJ71GP21S-SX firmware version '47' and earlier, and RJ71GN11-T2 firmware version '11' and earlier) allows a remote unauthenticated attacker to cause an error in a CPU unit and cause a denial-of-service (DoS) condition in execution of the program and its communication, or to cause a denial-of-service (DoS) condition in communication via the unit by receiving a specially crafted SLMP packet
References
▼ | URL | Tags |
---|---|---|
https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-016.pdf | x_refsource_MISC | |
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-016_en.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-20-324-05 | x_refsource_MISC | |
https://jvn.jp/vu/JVNVU95980140/index.html | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Mitsubishi Electric Corporation | MELSEC iQ-R |
Version: R00/01/02CPU firmware version '19' and earlier, R04/08/16/32/120 (EN) CPU firmware version '51' and earlier, R08/16/32/120SFCPU firmware version '22' and earlier, R08/16/32/120PCPU firmware version '25' and earlier, R08/16/32/120PSFCPU firmware version '06' and earlier, RJ71EN71 firmware version '47' and earlier, RJ71GF11-T2 firmware version '47' and earlier, RJ72GF15-T2 firmware version '07' and earlier, RJ71GP21-SX firmware version '47' and earlier, RJ71GP21S-SX firmware version '47' and earlier, and RJ71GN11-T2 firmware version '11' and earlier |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T08:39:25.511Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-016.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-016_en.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-324-05" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU95980140/index.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "MELSEC iQ-R", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "R00/01/02CPU firmware version \u002719\u0027 and earlier, R04/08/16/32/120 (EN) CPU firmware version \u002751\u0027 and earlier, R08/16/32/120SFCPU firmware version \u002722\u0027 and earlier, R08/16/32/120PCPU firmware version \u002725\u0027 and earlier, R08/16/32/120PSFCPU firmware version \u002706\u0027 and earlier, RJ71EN71 firmware version \u002747\u0027 and earlier, RJ71GF11-T2 firmware version \u002747\u0027 and earlier, RJ72GF15-T2 firmware version \u002707\u0027 and earlier, RJ71GP21-SX firmware version \u002747\u0027 and earlier, RJ71GP21S-SX firmware version \u002747\u0027 and earlier, and RJ71GN11-T2 firmware version \u002711\u0027 and earlier" } ] } ], "descriptions": [ { "lang": "en", "value": "Uncontrolled resource consumption vulnerability in MELSEC iQ-R Series modules (R00/01/02CPU firmware version \u002719\u0027 and earlier, R04/08/16/32/120 (EN) CPU firmware version \u002751\u0027 and earlier, R08/16/32/120SFCPU firmware version \u002722\u0027 and earlier, R08/16/32/120PCPU firmware version \u002725\u0027 and earlier, R08/16/32/120PSFCPU firmware version \u002706\u0027 and earlier, RJ71EN71 firmware version \u002747\u0027 and earlier, RJ71GF11-T2 firmware version \u002747\u0027 and earlier, RJ72GF15-T2 firmware version \u002707\u0027 and earlier, RJ71GP21-SX firmware version \u002747\u0027 and earlier, RJ71GP21S-SX firmware version \u002747\u0027 and earlier, and RJ71GN11-T2 firmware version \u002711\u0027 and earlier) allows a remote unauthenticated attacker to cause an error in a CPU unit and cause a denial-of-service (DoS) condition in execution of the program and its communication, or to cause a denial-of-service (DoS) condition in communication via the unit by receiving a specially crafted SLMP packet" } ], "problemTypes": [ { "descriptions": [ { "description": "Uncontrolled Resource Consumption", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-17T11:15:29", "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "shortName": "jpcert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-016.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-016_en.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-324-05" }, { "tags": [ "x_refsource_MISC" ], "url": "https://jvn.jp/vu/JVNVU95980140/index.html" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vultures@jpcert.or.jp", "ID": "CVE-2020-5668", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "MELSEC iQ-R", "version": { "version_data": [ { "version_value": "R00/01/02CPU firmware version \u002719\u0027 and earlier, R04/08/16/32/120 (EN) CPU firmware version \u002751\u0027 and earlier, R08/16/32/120SFCPU firmware version \u002722\u0027 and earlier, R08/16/32/120PCPU firmware version \u002725\u0027 and earlier, R08/16/32/120PSFCPU firmware version \u002706\u0027 and earlier, RJ71EN71 firmware version \u002747\u0027 and earlier, RJ71GF11-T2 firmware version \u002747\u0027 and earlier, RJ72GF15-T2 firmware version \u002707\u0027 and earlier, RJ71GP21-SX firmware version \u002747\u0027 and earlier, RJ71GP21S-SX firmware version \u002747\u0027 and earlier, and RJ71GN11-T2 firmware version \u002711\u0027 and earlier" } ] } } ] }, "vendor_name": "Mitsubishi Electric Corporation" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Uncontrolled resource consumption vulnerability in MELSEC iQ-R Series modules (R00/01/02CPU firmware version \u002719\u0027 and earlier, R04/08/16/32/120 (EN) CPU firmware version \u002751\u0027 and earlier, R08/16/32/120SFCPU firmware version \u002722\u0027 and earlier, R08/16/32/120PCPU firmware version \u002725\u0027 and earlier, R08/16/32/120PSFCPU firmware version \u002706\u0027 and earlier, RJ71EN71 firmware version \u002747\u0027 and earlier, RJ71GF11-T2 firmware version \u002747\u0027 and earlier, RJ72GF15-T2 firmware version \u002707\u0027 and earlier, RJ71GP21-SX firmware version \u002747\u0027 and earlier, RJ71GP21S-SX firmware version \u002747\u0027 and earlier, and RJ71GN11-T2 firmware version \u002711\u0027 and earlier) allows a remote unauthenticated attacker to cause an error in a CPU unit and cause a denial-of-service (DoS) condition in execution of the program and its communication, or to cause a denial-of-service (DoS) condition in communication via the unit by receiving a specially crafted SLMP packet" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-016.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-016.pdf" }, { "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-016_en.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-016_en.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-324-05", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-324-05" }, { "name": "https://jvn.jp/vu/JVNVU95980140/index.html", "refsource": "MISC", "url": "https://jvn.jp/vu/JVNVU95980140/index.html" } ] } } } }, "cveMetadata": { "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "assignerShortName": "jpcert", "cveId": "CVE-2020-5668", "datePublished": "2020-11-20T03:30:23", "dateReserved": "2020-01-06T00:00:00", "dateUpdated": "2024-08-04T08:39:25.511Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-20591
Vulnerability from cvelistv5
Published
2021-06-11 15:52
Modified
2024-08-03 17:45
Severity ?
EPSS score ?
Summary
Uncontrolled Resource Consumption vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules (R00/01/02CPU all versions, R04/08/16/32/120(EN)CPU all versions, R08/16/32/120SFCPU all versions, R08/16/32/120PCPU all versions, R08/16/32/120PSFCPU all versions) allows a remote unauthenticated attacker to prevent legitimate clients from connecting to the MELSOFT transmission port (TCP/IP) by not closing a connection properly, which may lead to a denial of service (DoS) condition.
References
▼ | URL | Tags |
---|---|---|
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-003_en.pdf | x_refsource_MISC | |
https://jvn.jp/vu/JVNVU98060539/index.html | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | MELSEC iQ-R series CPU modules |
Version: R00/01/02CPU all versions, R04/08/16/32/120(EN)CPU all versions, R08/16/32/120SFCPU all versions, R08/16/32/120PCPU all versions, R08/16/32/120PSFCPU all versions |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T17:45:44.388Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-003_en.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU98060539/index.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "MELSEC iQ-R series CPU modules", "vendor": "n/a", "versions": [ { "status": "affected", "version": "R00/01/02CPU all versions, R04/08/16/32/120(EN)CPU all versions, R08/16/32/120SFCPU all versions, R08/16/32/120PCPU all versions, R08/16/32/120PSFCPU all versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Uncontrolled Resource Consumption vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules (R00/01/02CPU all versions, R04/08/16/32/120(EN)CPU all versions, R08/16/32/120SFCPU all versions, R08/16/32/120PCPU all versions, R08/16/32/120PSFCPU all versions) allows a remote unauthenticated attacker to prevent legitimate clients from connecting to the MELSOFT transmission port (TCP/IP) by not closing a connection properly, which may lead to a denial of service (DoS) condition." } ], "problemTypes": [ { "descriptions": [ { "description": "Uncontrolled Resource Consumption", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-06-11T15:52:45", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-003_en.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://jvn.jp/vu/JVNVU98060539/index.html" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "ID": "CVE-2021-20591", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "MELSEC iQ-R series CPU modules", "version": { "version_data": [ { "version_value": "R00/01/02CPU all versions, R04/08/16/32/120(EN)CPU all versions, R08/16/32/120SFCPU all versions, R08/16/32/120PCPU all versions, R08/16/32/120PSFCPU all versions" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Uncontrolled Resource Consumption vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules (R00/01/02CPU all versions, R04/08/16/32/120(EN)CPU all versions, R08/16/32/120SFCPU all versions, R08/16/32/120PCPU all versions, R08/16/32/120PSFCPU all versions) allows a remote unauthenticated attacker to prevent legitimate clients from connecting to the MELSOFT transmission port (TCP/IP) by not closing a connection properly, which may lead to a denial of service (DoS) condition." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-003_en.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-003_en.pdf" }, { "name": "https://jvn.jp/vu/JVNVU98060539/index.html", "refsource": "MISC", "url": "https://jvn.jp/vu/JVNVU98060539/index.html" } ] } } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2021-20591", "datePublished": "2021-06-11T15:52:45", "dateReserved": "2020-12-17T00:00:00", "dateUpdated": "2024-08-03T17:45:44.388Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-20597
Vulnerability from cvelistv5
Published
2021-08-06 00:00
Modified
2024-08-03 17:45
Severity ?
EPSS score ?
Summary
Insufficiently Protected Credentials vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions "26" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions "11" and prior allows a remote unauthenticated attacker to login to the target unauthorizedly by sniffing network traffic and obtaining credentials when registering user information in the target or changing a password.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU; Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU |
Version: Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions "26" and prior Version: Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions "11" and prior |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T17:45:44.727Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-009_en.pdf" }, { "tags": [ "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU98578731/index.html" }, { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-250-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU; Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions \"26\" and prior" }, { "status": "affected", "version": "Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions \"11\" and prior" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eInsufficiently Protected Credentials vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions \"26\" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions \"11\" and prior allows a remote unauthenticated attacker to login to the target unauthorizedly by sniffing network traffic and obtaining credentials when registering user information in the target or changing a password.\u003c/p\u003e" } ], "value": "Insufficiently Protected Credentials vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions \"26\" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions \"11\" and prior allows a remote unauthenticated attacker to login to the target unauthorizedly by sniffing network traffic and obtaining credentials when registering user information in the target or changing a password." } ], "problemTypes": [ { "descriptions": [ { "description": "Insufficiently Protected Credentials", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-24T07:50:28.720Z", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-009_en.pdf" }, { "url": "https://jvn.jp/vu/JVNVU98578731/index.html" }, { "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-250-01" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2021-20597", "datePublished": "2021-08-06T00:00:00", "dateReserved": "2020-12-17T00:00:00", "dateUpdated": "2024-08-03T17:45:44.727Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-20598
Vulnerability from cvelistv5
Published
2021-08-06 16:53
Modified
2024-08-03 17:45
Severity ?
EPSS score ?
Summary
Overly Restrictive Account Lockout Mechanism vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules (R08/16/32/120SFCPU all versions, R08/16/32/120PSFCPU all versions) allows a remote unauthenticated attacker to lockout a legitimate user by continuously trying login with incorrect password.
References
▼ | URL | Tags |
---|---|---|
https://jvn.jp/vu/JVNVU98578731/index.html | x_refsource_MISC | |
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-010_en.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | MELSEC iQ-R series CPU modules R08/16/32/120SFCPU; R08/16/32/120PSFCPU |
Version: all versions |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T17:45:44.713Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU98578731/index.html" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-010_en.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "MELSEC iQ-R series CPU modules R08/16/32/120SFCPU; R08/16/32/120PSFCPU", "vendor": "n/a", "versions": [ { "status": "affected", "version": "all versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Overly Restrictive Account Lockout Mechanism vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules (R08/16/32/120SFCPU all versions, R08/16/32/120PSFCPU all versions) allows a remote unauthenticated attacker to lockout a legitimate user by continuously trying login with incorrect password." } ], "problemTypes": [ { "descriptions": [ { "description": "Overly Restrictive Account Lockout Mechanism", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-06T16:53:47", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://jvn.jp/vu/JVNVU98578731/index.html" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-010_en.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "ID": "CVE-2021-20598", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "MELSEC iQ-R series CPU modules R08/16/32/120SFCPU; R08/16/32/120PSFCPU", "version": { "version_data": [ { "version_value": "all versions" }, { "version_value": "all versions" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Overly Restrictive Account Lockout Mechanism vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules (R08/16/32/120SFCPU all versions, R08/16/32/120PSFCPU all versions) allows a remote unauthenticated attacker to lockout a legitimate user by continuously trying login with incorrect password." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Overly Restrictive Account Lockout Mechanism" } ] } ] }, "references": { "reference_data": [ { "name": "https://jvn.jp/vu/JVNVU98578731/index.html", "refsource": "MISC", "url": "https://jvn.jp/vu/JVNVU98578731/index.html" }, { "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-010_en.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-010_en.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2021-20598", "datePublished": "2021-08-06T16:53:47", "dateReserved": "2020-12-17T00:00:00", "dateUpdated": "2024-08-03T17:45:44.713Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-6815
Vulnerability from cvelistv5
Published
2024-02-13 06:27
Modified
2024-08-02 08:42
Severity ?
EPSS score ?
Summary
Incorrect Privilege Assignment vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series Safety CPU R08/16/32/120SFCPU all versions and MELSEC iQ-R Series SIL2 Process CPU R08/16/32/120PSFCPU all versions allows a remote authenticated attacker who has logged into the product as a non-administrator user to disclose the credentials (user ID and password) of a user with a lower access level than the attacker by sending a specially crafted packet.
References
▼ | URL | Tags |
---|---|---|
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-021_en.pdf | vendor-advisory | |
https://jvn.jp/vu/JVNVU95085830/index.html | government-resource | |
https://www.cisa.gov/news-events/ics-advisories/icsa-24-044-01 | government-resource |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Mitsubishi Electric Corporation | MELSEC iQ-R Series Safety CPU R08SFCPU |
Version: all versions |
||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2023-6815", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-02-13T16:44:26.588675Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:17:01.365Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T08:42:07.419Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-021_en.pdf" }, { "tags": [ "government-resource", "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU95085830/index.html" }, { "tags": [ "government-resource", "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-044-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "MELSEC iQ-R Series Safety CPU R08SFCPU", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "MELSEC iQ-R Series Safety CPU R16SFCPU", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "MELSEC iQ-R Series Safety CPU R32SFCPU", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "MELSEC iQ-R Series Safety CPU R120SFCPU", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "MELSEC iQ-R Series SIL2 Process CPU R08PSFCPU", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "MELSEC iQ-R Series SIL2 Process CPU R16PSFCPU", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "MELSEC iQ-R Series SIL2 Process CPU R32PSFCPU", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "MELSEC iQ-R Series SIL2 Process CPU R120PSFCPU", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Incorrect Privilege Assignment vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series Safety CPU R08/16/32/120SFCPU all versions and MELSEC iQ-R Series SIL2 Process CPU R08/16/32/120PSFCPU all versions allows a remote authenticated attacker who has logged into the product as a non-administrator user to disclose the credentials (user ID and password) of a user with a lower access level than the attacker by sending a specially crafted packet." } ], "value": "Incorrect Privilege Assignment vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series Safety CPU R08/16/32/120SFCPU all versions and MELSEC iQ-R Series SIL2 Process CPU R08/16/32/120PSFCPU all versions allows a remote authenticated attacker who has logged into the product as a non-administrator user to disclose the credentials (user ID and password) of a user with a lower access level than the attacker by sending a specially crafted packet." } ], "impacts": [ { "descriptions": [ { "lang": "en", "value": "Information Disclosure" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-266", "description": "CWE-266 Incorrect Privilege Assignment", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-02-14T03:59:42.705Z", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-021_en.pdf" }, { "tags": [ "government-resource" ], "url": "https://jvn.jp/vu/JVNVU95085830/index.html" }, { "tags": [ "government-resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-044-01" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2023-6815", "datePublished": "2024-02-13T06:27:51.202Z", "dateReserved": "2023-12-14T02:59:09.887Z", "dateUpdated": "2024-08-02T08:42:07.419Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-20599
Vulnerability from cvelistv5
Published
2021-10-14 00:00
Modified
2024-08-03 17:45
Severity ?
EPSS score ?
Summary
Cleartext Transmission of Sensitive InformationCleartext transmission of sensitive information vulnerability in MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU firmware versions "26" and prior and MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU firmware versions "11" and prior allows a remote unauthenticated attacker to login to a target CPU module by obtaining credentials other than password.
References
▼ | URL | Tags |
---|---|---|
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-011_en.pdf | vendor-advisory | |
https://jvn.jp/vu/JVNVU98578731 | government-resource | |
https://www.cisa.gov/uscert/ics/advisories/icsa-21-287-03 | government-resource |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Mitsubishi Electric Corporation | MELSEC iQ-R Series Safety CPU R08SFCPU |
Version: Firmware versions "26" and prior |
||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:mitsubishielectric:melsec_iq-r08sfcpu:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "melsec_iq-r08sfcpu", "vendor": "mitsubishielectric", "versions": [ { "status": "affected", "version": "-" } ] }, { "cpes": [ "cpe:2.3:h:mitsubishielectric:r16sfcpu:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "r16sfcpu", "vendor": "mitsubishielectric", "versions": [ { "status": "affected", "version": "-" } ] }, { "cpes": [ "cpe:2.3:h:mitsubishielectric:r32sfcpu:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "r32sfcpu", "vendor": "mitsubishielectric", "versions": [ { "status": "affected", "version": "-" } ] }, { "cpes": [ "cpe:2.3:h:mitsubishielectric:r120sfcpu:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "r120sfcpu", "vendor": "mitsubishielectric", "versions": [ { "status": "affected", "version": "-" } ] }, { "cpes": [ "cpe:2.3:h:mitsubishielectric:r08psfcpu:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "r08psfcpu", "vendor": "mitsubishielectric", "versions": [ { "status": "affected", "version": "-" } ] }, { "cpes": [ "cpe:2.3:h:mitsubishielectric:r16psfcpu:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "r16psfcpu", "vendor": "mitsubishielectric", "versions": [ { "status": "affected", "version": "-" } ] }, { "cpes": [ "cpe:2.3:h:mitsubishielectric:r32psfcpu:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "r32psfcpu", "vendor": "mitsubishielectric", "versions": [ { "status": "affected", "version": "-" } ] }, { "cpes": [ "cpe:2.3:h:mitsubishielectric:r120psfcpu:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "r120psfcpu", "vendor": "mitsubishielectric", "versions": [ { "status": "affected", "version": "-" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2021-20599", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-04-22T20:51:10.357119Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:12:41.515Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-03T17:45:44.681Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-011_en.pdf" }, { "tags": [ "government-resource", "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU98578731" }, { "tags": [ "government-resource", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-287-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "MELSEC iQ-R Series Safety CPU R08SFCPU", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "Firmware versions \"26\" and prior" } ] }, { "defaultStatus": "unaffected", "product": "MELSEC iQ-R series Safety CPU R16SFCPU", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "Firmware versions \"26\" and prior" } ] }, { "defaultStatus": "unaffected", "product": "MELSEC iQ-R series Safety CPU R32SFCPU", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "Firmware versions \"26\" and prior" } ] }, { "defaultStatus": "unaffected", "product": "MELSEC iQ-R series Safety CPU R120SFCPU", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "Firmware versions \"26\" and prior" } ] }, { "defaultStatus": "unaffected", "product": "MELSEC iQ-R Series SIL2 Process CPU R08PSFCPU", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "Firmware versions \"11\" and prior" } ] }, { "defaultStatus": "unaffected", "product": "MELSEC iQ-R series SIL2 Process CPU R16PSFCPU", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "Firmware versions \"11\" and prior" } ] }, { "defaultStatus": "unaffected", "product": "MELSEC iQ-R series SIL2 Process CPU R32PSFCPU", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "Firmware versions \"11\" and prior" } ] }, { "defaultStatus": "unaffected", "product": "MELSEC iQ-R series SIL2 Process CPU R120PSFCPU", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "Firmware versions \"11\" and prior" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Cleartext Transmission of Sensitive InformationCleartext transmission of sensitive information vulnerability in MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU firmware versions \"26\" and prior and MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU firmware versions \"11\" and prior allows a remote unauthenticated attacker to login to a target CPU module by obtaining credentials other than password." } ], "value": "Cleartext Transmission of Sensitive InformationCleartext transmission of sensitive information vulnerability in MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU firmware versions \"26\" and prior and MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU firmware versions \"11\" and prior allows a remote unauthenticated attacker to login to a target CPU module by obtaining credentials other than password." } ], "impacts": [ { "capecId": "CAPEC-115", "descriptions": [ { "lang": "en", "value": "CAPEC-115 Authentication Bypass" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-319", "description": "CWE-319 Cleartext Transmission of Sensitive Information", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-18T05:28:04.068Z", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-011_en.pdf" }, { "tags": [ "government-resource" ], "url": "https://jvn.jp/vu/JVNVU98578731" }, { "tags": [ "government-resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-287-03" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2021-20599", "datePublished": "2021-10-14T00:00:00", "dateReserved": "2020-12-17T00:00:00", "dateUpdated": "2024-08-03T17:45:44.681Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-20594
Vulnerability from cvelistv5
Published
2021-08-06 00:00
Modified
2024-08-03 17:45
Severity ?
EPSS score ?
Summary
Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions "26" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions "11" and prior allows a remote unauthenticated attacker to acquire legitimate user names registered in the module via brute-force attack on user names.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU; Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU |
Version: Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions "26" and prior Version: Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions "11" and prior |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T17:45:44.726Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU98578731/index.html" }, { "tags": [ "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-008_en.pdf" }, { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-250-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU; Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions \"26\" and prior" }, { "status": "affected", "version": "Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions \"11\" and prior" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eExposure of Sensitive Information to an Unauthorized Actor vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions \"26\" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions \"11\" and prior allows a remote unauthenticated attacker to acquire legitimate user names registered in the module via brute-force attack on user names.\u003c/p\u003e" } ], "value": "Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions \"26\" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions \"11\" and prior allows a remote unauthenticated attacker to acquire legitimate user names registered in the module via brute-force attack on user names." } ], "problemTypes": [ { "descriptions": [ { "description": "Exposure of Sensitive Information to an Unauthorized Actor", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-24T07:53:21.422Z", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "url": "https://jvn.jp/vu/JVNVU98578731/index.html" }, { "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-008_en.pdf" }, { "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-250-01" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2021-20594", "datePublished": "2021-08-06T00:00:00", "dateReserved": "2020-12-17T00:00:00", "dateUpdated": "2024-08-03T17:45:44.726Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2021-08-06 17:15
Modified
2024-11-21 05:46
Severity ?
Summary
Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions "26" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions "11" and prior allows a remote unauthenticated attacker to acquire legitimate user names registered in the module via brute-force attack on user names.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r08sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66D3AC7B-50E0-47D5-B0D1-07329D724EFE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r08sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "B185323A-C9E3-48A0-AD28-DA7AC7846E18", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r16sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA81D5C7-46C8-4F0E-9550-D240DC0366F3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r16sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "C4BBE066-33C4-4410-85D3-4B77B3773330", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r32sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FB53D61-6C69-4A4A-92B1-C10D0B8F0EC9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r32sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6304BE-DAEE-49AB-B0B1-CEE6878CBECE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r120sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8218130C-4E7D-4FB9-976B-2351977C82D4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r120sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "515BDC46-5A1C-4A94-816A-B4751BB1B58D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r08psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5A63D33D-302A-428C-986F-FC3F83CE9C86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r08psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "EA37F2FC-8F75-4FEA-882D-87AD5CC1558E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r16psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FFB42739-E503-44B2-A020-0DB2B8791A81", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r16psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "17AD5875-B7D7-498B-9484-23049753133E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r32psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B1F532B-8EAF-4E66-9AF5-5EEFF5A0BC23", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r32psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "0EC2594C-6067-40BA-B8B2-AEC9B9C7922F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r120psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B2C03EA2-34BF-4F86-A19C-2818788E092B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r120psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA3FB3E1-D7D3-424B-A207-D3C6F4365D12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions \"26\" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions \"11\" and prior allows a remote unauthenticated attacker to acquire legitimate user names registered in the module via brute-force attack on user names." }, { "lang": "es", "value": "La exposici\u00f3n de informaci\u00f3n sensible a un actor no autorizado es una vulnerabilidad en los m\u00f3dulos de CPU de seguridad de la serie MELSEC iQ-R de Mitsubishi Electric R08/16/32/120SFCPU, versiones de firmware \"26\" y anteriores, y en los m\u00f3dulos de CPU de proceso SIL2 de la serie MELSEC iQ-R de Mitsubishi Electric R08/16/32/120PSFCPU, todas las versiones, que permite a un atacante remoto no autenticado adquirir nombres de usuario leg\u00edtimos registrados en el m\u00f3dulo mediante un ataque de fuerza bruta a los nombres de usuario" } ], "id": "CVE-2021-20594", "lastModified": "2024-11-21T05:46:50.623", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-08-06T17:15:07.103", "references": [ { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU98578731/index.html" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-250-01" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-008_en.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU98578731/index.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-250-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-008_en.pdf" } ], "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-08-06 17:15
Modified
2024-11-21 05:46
Severity ?
Summary
Insufficiently Protected Credentials vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions "26" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions "11" and prior allows a remote unauthenticated attacker to login to the target unauthorizedly by sniffing network traffic and obtaining credentials when registering user information in the target or changing a password.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r08sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66D3AC7B-50E0-47D5-B0D1-07329D724EFE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r08sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "B185323A-C9E3-48A0-AD28-DA7AC7846E18", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r16sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA81D5C7-46C8-4F0E-9550-D240DC0366F3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r16sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "C4BBE066-33C4-4410-85D3-4B77B3773330", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r32sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FB53D61-6C69-4A4A-92B1-C10D0B8F0EC9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r32sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6304BE-DAEE-49AB-B0B1-CEE6878CBECE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r120sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8218130C-4E7D-4FB9-976B-2351977C82D4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r120sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "515BDC46-5A1C-4A94-816A-B4751BB1B58D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r08psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5A63D33D-302A-428C-986F-FC3F83CE9C86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r08psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "EA37F2FC-8F75-4FEA-882D-87AD5CC1558E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r16psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FFB42739-E503-44B2-A020-0DB2B8791A81", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r16psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "17AD5875-B7D7-498B-9484-23049753133E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r32psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B1F532B-8EAF-4E66-9AF5-5EEFF5A0BC23", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r32psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "0EC2594C-6067-40BA-B8B2-AEC9B9C7922F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r120psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B2C03EA2-34BF-4F86-A19C-2818788E092B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r120psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA3FB3E1-D7D3-424B-A207-D3C6F4365D12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Insufficiently Protected Credentials vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions \"26\" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions \"11\" and prior allows a remote unauthenticated attacker to login to the target unauthorizedly by sniffing network traffic and obtaining credentials when registering user information in the target or changing a password." }, { "lang": "es", "value": "La vulnerabilidad de credenciales insuficientemente protegidas en los m\u00f3dulos de CPU de seguridad de la serie MELSEC iQ-R de Mitsubishi Electric R08/16/32/120SFCPU, versiones de firmware \"26\" y anteriores, y en los m\u00f3dulos de CPU de proceso SIL2 de la serie MELSEC iQ-R de Mitsubishi Electric R08/16/32/120PSFCPU, todas las versiones, permite que un atacante remoto no autenticado inicie sesi\u00f3n en el objetivo de forma no autorizada mediante el olfateo del tr\u00e1fico de red y la obtenci\u00f3n de credenciales al registrar informaci\u00f3n de usuario en el objetivo o al cambiar una contrase\u00f1a" } ], "id": "CVE-2021-20597", "lastModified": "2024-11-21T05:46:51.063", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 6.4, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-08-06T17:15:07.140", "references": [ { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU98578731/index.html" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-250-01" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-009_en.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU98578731/index.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-250-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-009_en.pdf" } ], "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-522" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-11-20 04:15
Modified
2024-11-21 05:34
Severity ?
Summary
Uncontrolled resource consumption vulnerability in MELSEC iQ-R Series modules (R00/01/02CPU firmware version '19' and earlier, R04/08/16/32/120 (EN) CPU firmware version '51' and earlier, R08/16/32/120SFCPU firmware version '22' and earlier, R08/16/32/120PCPU firmware version '25' and earlier, R08/16/32/120PSFCPU firmware version '06' and earlier, RJ71EN71 firmware version '47' and earlier, RJ71GF11-T2 firmware version '47' and earlier, RJ72GF15-T2 firmware version '07' and earlier, RJ71GP21-SX firmware version '47' and earlier, RJ71GP21S-SX firmware version '47' and earlier, and RJ71GN11-T2 firmware version '11' and earlier) allows a remote unauthenticated attacker to cause an error in a CPU unit and cause a denial-of-service (DoS) condition in execution of the program and its communication, or to cause a denial-of-service (DoS) condition in communication via the unit by receiving a specially crafted SLMP packet
References
▼ | URL | Tags | |
---|---|---|---|
vultures@jpcert.or.jp | https://jvn.jp/vu/JVNVU95980140/index.html | Third Party Advisory | |
vultures@jpcert.or.jp | https://us-cert.cisa.gov/ics/advisories/icsa-20-324-05 | Third Party Advisory, US Government Resource | |
vultures@jpcert.or.jp | https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-016.pdf | Vendor Advisory | |
vultures@jpcert.or.jp | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-016_en.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://jvn.jp/vu/JVNVU95980140/index.html | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-20-324-05 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-016.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-016_en.pdf | Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r00cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6314D599-F0B6-4D42-A6F5-985F09BD1694", "versionEndIncluding": "19", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r00cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "B0A23F21-9C5F-4CB3-BA20-4195B2165D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r01cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CAB241EF-238E-44BF-8995-4DC2EC4DBF69", "versionEndIncluding": "19", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r01cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "CADF6528-4B25-4779-A06F-2C4DF91DAE90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r02cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD971E61-145F-425C-A5E0-788CA22A9464", "versionEndIncluding": "19", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r02cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "2D753C47-ED9C-453F-AC1F-C50476BE61C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r04cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "17518878-FF10-498F-A506-93D76D5F6371", "versionEndIncluding": "51", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r04cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "BDEEF15E-FE32-4610-9E14-891069573E4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r08cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AFAE4231-9FC7-4744-8652-1AC0202C5298", "versionEndIncluding": "51", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r08cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "2DAA2202-88D5-4329-BF51-0F18C350C45C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r16cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C4C99DED-CA7F-496A-ADDF-3B2C8D5D6792", "versionEndIncluding": "51", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r16cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "30016EA0-FB24-4382-8960-6A75D32C9BD7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r32cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B1D0609F-30CB-424B-890E-F9BDF8A6606F", "versionEndIncluding": "51", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r32cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAF6EB84-7D97-4606-A90F-9D443CBC4755", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r120cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BC00F22C-BFEF-41E9-9B49-9FDE2B0D5804", "versionEndIncluding": "51", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r120cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "3EF7D08E-D3D1-48D4-9440-B94B7A2BD662", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r08sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E49CF5A5-8F0E-4E41-9B6F-15641CD32E29", "versionEndIncluding": "22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r08sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "B185323A-C9E3-48A0-AD28-DA7AC7846E18", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r16sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "844B3E94-7F24-4523-AE29-55D5C55D4A99", "versionEndIncluding": "22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r16sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "C4BBE066-33C4-4410-85D3-4B77B3773330", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r32sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "15096442-7E6B-4846-9A8F-01023A54DFA0", "versionEndIncluding": "22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r32sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6304BE-DAEE-49AB-B0B1-CEE6878CBECE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r120sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4DE2946C-E8C0-4253-B84C-16A81767343E", "versionEndIncluding": "22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r120sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "515BDC46-5A1C-4A94-816A-B4751BB1B58D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r08pcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F94C8F7E-8626-434C-A699-99751BE9D60E", "versionEndIncluding": "25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r08pcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "3845683A-A4D2-422F-9736-D0D7A430555F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r16pcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D993D0D-FA5B-4819-86C2-F182464CFFAF", "versionEndIncluding": "25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r16pcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "EA04F2DD-4D51-4D4F-B3C7-D5EFACAD6EFB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r32pcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A7354680-CF1D-4CA6-BC3F-39DA0B621612", "versionEndIncluding": "25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r32pcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "3EA2A77C-86CE-48E1-87A4-A69895102D49", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r120pcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "974AB564-75E3-4ADF-9F25-7DFDCFF4D03A", "versionEndIncluding": "25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r120pcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "E0FE9EA6-6BCE-40F7-8AE8-173F7CDF3EF6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r08psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42566660-1AD6-466C-B07C-D263F701774B", "versionEndIncluding": "06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r08psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "EA37F2FC-8F75-4FEA-882D-87AD5CC1558E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r16psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "732D97FD-3D80-43A6-B41A-3B3BFC09E152", "versionEndIncluding": "06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r16psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "17AD5875-B7D7-498B-9484-23049753133E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r32psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B92974DE-CD79-470B-9308-6D4FEF1C689B", "versionEndIncluding": "06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r32psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "0EC2594C-6067-40BA-B8B2-AEC9B9C7922F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r120psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9DA8768-E0AD-4603-9C3C-AE7E02BEFBC9", "versionEndIncluding": "06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r120psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA3FB3E1-D7D3-424B-A207-D3C6F4365D12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rj71en71_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C9EDD7F7-18C8-424E-9808-409080AAC764", "versionEndIncluding": "47", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rj71en71:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BD2CE10-A6DB-4642-8FA8-DD1AFA726EC7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rj71gf11-t2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5EDC22E7-38B1-42DF-9F48-BAB477156B54", "versionEndIncluding": "47", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rj71gf11-t2:-:*:*:*:*:*:*:*", "matchCriteriaId": "AA16A0DE-CBBD-4871-85C8-1F3AD7D2A074", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rj72gf15-t2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A35CD177-3A86-4E6A-99CE-089CCDD38A14", "versionEndIncluding": "07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rj72gf15-t2:-:*:*:*:*:*:*:*", "matchCriteriaId": "FC7B087E-9F37-4D35-90E3-3BAB91D4A69C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rj71gp21-sx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "918EA7ED-100C-4A4B-B848-C41E0B821FE3", "versionEndIncluding": "47", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rj71gp21-sx:-:*:*:*:*:*:*:*", "matchCriteriaId": "F31A6CCB-56E8-4C79-8121-B0DFAB4C32E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rj71gp21s-sx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E54F3518-DB4E-4DE1-B97D-37860CF88BAC", "versionEndIncluding": "47", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rj71gp21s-sx:-:*:*:*:*:*:*:*", "matchCriteriaId": "95224DAD-C888-451D-9A2B-F7583A5837B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rj71c24-r2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DDBD7FC5-859D-419E-BAAE-B4E58FDA0887", "versionEndIncluding": "47", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rj71c24-r2:-:*:*:*:*:*:*:*", "matchCriteriaId": "2E93B863-EDC2-4584-B998-A0CF23824037", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rj71c24-r4_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61EA2C4A-216B-42EB-BA67-70C060C25DAC", "versionEndIncluding": "47", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rj71c24-r4:-:*:*:*:*:*:*:*", "matchCriteriaId": "3EB02306-42B5-46EA-AD6A-79041E36FA2A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rj71gn11-t2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "608DB833-3477-4596-80A5-99AE0A3A4993", "versionEndIncluding": "11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rj71gn11-t2:-:*:*:*:*:*:*:*", "matchCriteriaId": "A7B5FE39-4540-4A95-ABA8-15F8EA545DE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Uncontrolled resource consumption vulnerability in MELSEC iQ-R Series modules (R00/01/02CPU firmware version \u002719\u0027 and earlier, R04/08/16/32/120 (EN) CPU firmware version \u002751\u0027 and earlier, R08/16/32/120SFCPU firmware version \u002722\u0027 and earlier, R08/16/32/120PCPU firmware version \u002725\u0027 and earlier, R08/16/32/120PSFCPU firmware version \u002706\u0027 and earlier, RJ71EN71 firmware version \u002747\u0027 and earlier, RJ71GF11-T2 firmware version \u002747\u0027 and earlier, RJ72GF15-T2 firmware version \u002707\u0027 and earlier, RJ71GP21-SX firmware version \u002747\u0027 and earlier, RJ71GP21S-SX firmware version \u002747\u0027 and earlier, and RJ71GN11-T2 firmware version \u002711\u0027 and earlier) allows a remote unauthenticated attacker to cause an error in a CPU unit and cause a denial-of-service (DoS) condition in execution of the program and its communication, or to cause a denial-of-service (DoS) condition in communication via the unit by receiving a specially crafted SLMP packet" }, { "lang": "es", "value": "Vulnerabilidad de consumo incontrolado de recursos en los m\u00f3dulos de la serie iQ-R de MELSEC (R00/01/02CPU firmware versi\u00f3n \u002719\u0027 y anteriores, R04/08/16/32/120 (ES) CPU firmware versi\u00f3n \u002751\u0027 y anteriores, R08/16/32/120SFCPU firmware versi\u00f3n \u002722\u0027 y anteriores, R08/16/32/120PCPU firmware versi\u00f3n \u002725\u0027 y anterior, R08/16/32/120PSFCPU firmware versi\u00f3n \u002706\u0027 y anterior, RJ71EN71 firmware versi\u00f3n \u002747\u0027 y anterior, RJ71GF11-T2 firmware versi\u00f3n \u002747\u0027 y anterior, RJ72GF15-T2 firmware versi\u00f3n \u002707\u0027 y anterior, RJ71GP21-SX firmware versi\u00f3n \u002747\u0027 y anterior, RJ71GP21S-SX firmware versi\u00f3n \u002747\u0027 y anterior, y RJ71GN11-T2 firmware versi\u00f3n \u002711\u0027 y anteriores) permite a un atacante remoto no autentificado provocar un error en una CPU y causar una condici\u00f3n de denegaci\u00f3n de servicio (DoS) en la ejecuci\u00f3n del programa y su comunicaci\u00f3n, o causar una condici\u00f3n de denegaci\u00f3n de servicio (DoS) en la comunicaci\u00f3n a trav\u00e9s de la unidad mediante la recepci\u00f3n de un paquete SLMP especialmente dise\u00f1ado" } ], "id": "CVE-2020-5668", "lastModified": "2024-11-21T05:34:27.190", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-11-20T04:15:11.423", "references": [ { "source": "vultures@jpcert.or.jp", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU95980140/index.html" }, { "source": "vultures@jpcert.or.jp", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-324-05" }, { "source": "vultures@jpcert.or.jp", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-016.pdf" }, { "source": "vultures@jpcert.or.jp", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-016_en.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU95980140/index.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-324-05" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-016.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-016_en.pdf" } ], "sourceIdentifier": "vultures@jpcert.or.jp", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-10-14 15:15
Modified
2024-11-21 05:46
Severity ?
9.1 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Summary
Cleartext Transmission of Sensitive InformationCleartext transmission of sensitive information vulnerability in MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU firmware versions "26" and prior and MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU firmware versions "11" and prior allows a remote unauthenticated attacker to login to a target CPU module by obtaining credentials other than password.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r08sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66D3AC7B-50E0-47D5-B0D1-07329D724EFE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r08sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "B185323A-C9E3-48A0-AD28-DA7AC7846E18", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r16sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA81D5C7-46C8-4F0E-9550-D240DC0366F3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r16sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "C4BBE066-33C4-4410-85D3-4B77B3773330", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r32sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FB53D61-6C69-4A4A-92B1-C10D0B8F0EC9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r32sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6304BE-DAEE-49AB-B0B1-CEE6878CBECE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r120sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8218130C-4E7D-4FB9-976B-2351977C82D4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r120sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "515BDC46-5A1C-4A94-816A-B4751BB1B58D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r08psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5A63D33D-302A-428C-986F-FC3F83CE9C86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r08psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "EA37F2FC-8F75-4FEA-882D-87AD5CC1558E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r16psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FFB42739-E503-44B2-A020-0DB2B8791A81", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r16psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "17AD5875-B7D7-498B-9484-23049753133E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r32psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B1F532B-8EAF-4E66-9AF5-5EEFF5A0BC23", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r32psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "0EC2594C-6067-40BA-B8B2-AEC9B9C7922F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r120psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B2C03EA2-34BF-4F86-A19C-2818788E092B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r120psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA3FB3E1-D7D3-424B-A207-D3C6F4365D12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Cleartext Transmission of Sensitive InformationCleartext transmission of sensitive information vulnerability in MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU firmware versions \"26\" and prior and MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU firmware versions \"11\" and prior allows a remote unauthenticated attacker to login to a target CPU module by obtaining credentials other than password." }, { "lang": "es", "value": "La vulnerabilidad de transmisi\u00f3n de texto claro de informaci\u00f3n sensible en las versiones de firmware \"26\" y anteriores de la CPU de seguridad R08/16/32/120SFCPU de la serie iQ-R de MELSEC y en la CPU de proceso SIL2 R08/16/32/120PSFCPU de la serie iQ-R de MELSEC, en todas sus versiones, permite que un atacante remoto no autenticado inicie sesi\u00f3n en un m\u00f3dulo de CPU objetivo obteniendo credenciales distintas de la contrase\u00f1a" } ], "id": "CVE-2021-20599", "lastModified": "2024-11-21T05:46:51.317", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.2, "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-10-14T15:15:08.827", "references": [ { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU98578731" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-287-03" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-011_en.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU98578731" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-287-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-011_en.pdf" } ], "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-319" } ], "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-639" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-02-13 07:15
Modified
2024-11-21 08:44
Severity ?
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Summary
Incorrect Privilege Assignment vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series Safety CPU R08/16/32/120SFCPU all versions and MELSEC iQ-R Series SIL2 Process CPU R08/16/32/120PSFCPU all versions allows a remote authenticated attacker who has logged into the product as a non-administrator user to disclose the credentials (user ID and password) of a user with a lower access level than the attacker by sending a specially crafted packet.
References
▼ | URL | Tags | |
---|---|---|---|
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://jvn.jp/vu/JVNVU95085830/index.html | Third Party Advisory | |
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://www.cisa.gov/news-events/ics-advisories/icsa-24-044-01 | Third Party Advisory, US Government Resource | |
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-021_en.pdf | Mitigation, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://jvn.jp/vu/JVNVU95085830/index.html | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/news-events/ics-advisories/icsa-24-044-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-021_en.pdf | Mitigation, Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r08sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66D3AC7B-50E0-47D5-B0D1-07329D724EFE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r08sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "B185323A-C9E3-48A0-AD28-DA7AC7846E18", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r16sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA81D5C7-46C8-4F0E-9550-D240DC0366F3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r16sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "C4BBE066-33C4-4410-85D3-4B77B3773330", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r32sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FB53D61-6C69-4A4A-92B1-C10D0B8F0EC9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r32sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6304BE-DAEE-49AB-B0B1-CEE6878CBECE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r120sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8218130C-4E7D-4FB9-976B-2351977C82D4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r120sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "515BDC46-5A1C-4A94-816A-B4751BB1B58D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r08psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5A63D33D-302A-428C-986F-FC3F83CE9C86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r08psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "EA37F2FC-8F75-4FEA-882D-87AD5CC1558E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r16psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FFB42739-E503-44B2-A020-0DB2B8791A81", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r16psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "17AD5875-B7D7-498B-9484-23049753133E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r32psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B1F532B-8EAF-4E66-9AF5-5EEFF5A0BC23", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r32psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "0EC2594C-6067-40BA-B8B2-AEC9B9C7922F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r120psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B2C03EA2-34BF-4F86-A19C-2818788E092B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r120psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA3FB3E1-D7D3-424B-A207-D3C6F4365D12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Incorrect Privilege Assignment vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series Safety CPU R08/16/32/120SFCPU all versions and MELSEC iQ-R Series SIL2 Process CPU R08/16/32/120PSFCPU all versions allows a remote authenticated attacker who has logged into the product as a non-administrator user to disclose the credentials (user ID and password) of a user with a lower access level than the attacker by sending a specially crafted packet." }, { "lang": "es", "value": "Vulnerabilidad de asignaci\u00f3n de privilegios incorrecta en Mitsubishi Electric Corporation MELSEC iQ-R Series Safety CPU R08/16/32/120SFCPU todas las versiones y MELSEC iQ-R Series SIL2 Process CPU R08/16/32/120PSFCPU todas las versiones permite a un atacante autenticado remoto que haya iniciado sesi\u00f3n ingresa al producto como usuario no administrador para revelar las credenciales (ID de usuario y contrase\u00f1a) de un usuario con un nivel de acceso m\u00e1s bajo que el atacante mediante el env\u00edo de un paquete especialmente manipulado." } ], "id": "CVE-2023-6815", "lastModified": "2024-11-21T08:44:36.877", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-02-13T07:15:46.843", "references": [ { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU95085830/index.html" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-044-01" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-021_en.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU95085830/index.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-044-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-021_en.pdf" } ], "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-266" } ], "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-06-11 16:15
Modified
2024-11-21 05:46
Severity ?
Summary
Uncontrolled Resource Consumption vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules (R00/01/02CPU all versions, R04/08/16/32/120(EN)CPU all versions, R08/16/32/120SFCPU all versions, R08/16/32/120PCPU all versions, R08/16/32/120PSFCPU all versions) allows a remote unauthenticated attacker to prevent legitimate clients from connecting to the MELSOFT transmission port (TCP/IP) by not closing a connection properly, which may lead to a denial of service (DoS) condition.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r00cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B45CE88C-9D71-4F5F-B10B-ABBAE40597FD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r00cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "B0A23F21-9C5F-4CB3-BA20-4195B2165D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r01cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1D54E1B-A2E3-49E7-B7A0-B693AA9E410F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r01cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "CADF6528-4B25-4779-A06F-2C4DF91DAE90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r02cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "927EB3AB-4EE4-4FC0-AADE-939C2BB89850", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r02cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "2D753C47-ED9C-453F-AC1F-C50476BE61C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r04cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60DD8B4-CFF5-4331-8BC2-49D3583B0F6B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r04cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "BDEEF15E-FE32-4610-9E14-891069573E4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r08cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5755570C-4913-44C4-A906-BBB59616D336", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r08cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "2DAA2202-88D5-4329-BF51-0F18C350C45C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r16cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5996B1E9-F9AD-4890-833E-926B31AE9113", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r16cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "30016EA0-FB24-4382-8960-6A75D32C9BD7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r32cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F1B0629A-A3AA-4FEF-9F93-5E86DF3B9B16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r32cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAF6EB84-7D97-4606-A90F-9D443CBC4755", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r120cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C593DC3-776B-483C-A6B8-03A65671D4B1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r120cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "3EF7D08E-D3D1-48D4-9440-B94B7A2BD662", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r08sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66D3AC7B-50E0-47D5-B0D1-07329D724EFE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r08sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "B185323A-C9E3-48A0-AD28-DA7AC7846E18", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r16sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA81D5C7-46C8-4F0E-9550-D240DC0366F3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r16sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "C4BBE066-33C4-4410-85D3-4B77B3773330", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r32sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FB53D61-6C69-4A4A-92B1-C10D0B8F0EC9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r32sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6304BE-DAEE-49AB-B0B1-CEE6878CBECE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r120sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8218130C-4E7D-4FB9-976B-2351977C82D4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r120sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "515BDC46-5A1C-4A94-816A-B4751BB1B58D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r08pcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63442274-452B-4361-A2AD-2ACBD699B150", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r08pcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "3845683A-A4D2-422F-9736-D0D7A430555F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r16pcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE0EA636-84E9-4DAA-BE39-DBA9D7B857F4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r16pcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "EA04F2DD-4D51-4D4F-B3C7-D5EFACAD6EFB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r32pcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "275C5686-5333-440F-8C85-8C2FB91FC2DA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r32pcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "3EA2A77C-86CE-48E1-87A4-A69895102D49", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r120pcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5EC951AC-3538-4711-A034-6C1A94AD797F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r120pcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "E0FE9EA6-6BCE-40F7-8AE8-173F7CDF3EF6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r08psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5A63D33D-302A-428C-986F-FC3F83CE9C86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r08psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "EA37F2FC-8F75-4FEA-882D-87AD5CC1558E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r16psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FFB42739-E503-44B2-A020-0DB2B8791A81", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r16psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "17AD5875-B7D7-498B-9484-23049753133E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r32psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B1F532B-8EAF-4E66-9AF5-5EEFF5A0BC23", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r32psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "0EC2594C-6067-40BA-B8B2-AEC9B9C7922F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r120psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B2C03EA2-34BF-4F86-A19C-2818788E092B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r120psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA3FB3E1-D7D3-424B-A207-D3C6F4365D12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Uncontrolled Resource Consumption vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules (R00/01/02CPU all versions, R04/08/16/32/120(EN)CPU all versions, R08/16/32/120SFCPU all versions, R08/16/32/120PCPU all versions, R08/16/32/120PSFCPU all versions) allows a remote unauthenticated attacker to prevent legitimate clients from connecting to the MELSOFT transmission port (TCP/IP) by not closing a connection properly, which may lead to a denial of service (DoS) condition." }, { "lang": "es", "value": "Una vulnerabilidad de Consumo Incontrolado de Recursos en Mitsubishi Electric MELSEC iQ-R series CPU modules (R00/01/02CPU todas las versiones, R04/08/16/32/120(ES)CPU todas las versiones, R08/16/32/120SFCPU todas las versiones, R08/16/32/120PCPU todas las versiones, R08/16/32/120PSFCPU todas las versiones) permite a un atacante remoto no autentificado impedir que clientes leg\u00edtimos se conecten al puerto de transmisi\u00f3n de MELSOFT (TCP/IP) al no cerrar una conexi\u00f3n apropiadamente, lo que puede conllevar a una condici\u00f3n de denegaci\u00f3n de servicio (DoS)" } ], "id": "CVE-2021-20591", "lastModified": "2024-11-21T05:46:50.187", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-06-11T16:15:08.987", "references": [ { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU98060539/index.html" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-003_en.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU98060539/index.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-003_en.pdf" } ], "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-08-06 17:15
Modified
2024-11-21 05:46
Severity ?
Summary
Overly Restrictive Account Lockout Mechanism vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules (R08/16/32/120SFCPU all versions, R08/16/32/120PSFCPU all versions) allows a remote unauthenticated attacker to lockout a legitimate user by continuously trying login with incorrect password.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r08sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66D3AC7B-50E0-47D5-B0D1-07329D724EFE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r08sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "B185323A-C9E3-48A0-AD28-DA7AC7846E18", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r16sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA81D5C7-46C8-4F0E-9550-D240DC0366F3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r16sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "C4BBE066-33C4-4410-85D3-4B77B3773330", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r32sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FB53D61-6C69-4A4A-92B1-C10D0B8F0EC9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r32sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6304BE-DAEE-49AB-B0B1-CEE6878CBECE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r120sfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8218130C-4E7D-4FB9-976B-2351977C82D4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r120sfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "515BDC46-5A1C-4A94-816A-B4751BB1B58D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r08psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5A63D33D-302A-428C-986F-FC3F83CE9C86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r08psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "EA37F2FC-8F75-4FEA-882D-87AD5CC1558E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r16psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FFB42739-E503-44B2-A020-0DB2B8791A81", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r16psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "17AD5875-B7D7-498B-9484-23049753133E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r32psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B1F532B-8EAF-4E66-9AF5-5EEFF5A0BC23", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r32psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "0EC2594C-6067-40BA-B8B2-AEC9B9C7922F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:r120psfcpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B2C03EA2-34BF-4F86-A19C-2818788E092B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:r120psfcpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA3FB3E1-D7D3-424B-A207-D3C6F4365D12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Overly Restrictive Account Lockout Mechanism vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules (R08/16/32/120SFCPU all versions, R08/16/32/120PSFCPU all versions) allows a remote unauthenticated attacker to lockout a legitimate user by continuously trying login with incorrect password." }, { "lang": "es", "value": "Una vulnerabilidad del Mecanismo de Bloqueo de Cuentas Demasiado Restrictivo en los m\u00f3dulos de CPU de la serie MELSEC iQ-R de Mitsubishi Electric (R08/16/32/120SFCPU todas las versiones, R08/16/32/120PSFCPU todas las versiones) permite a un atacante remoto no autenticado bloquear a un usuario leg\u00edtimo al intentar iniciar sesi\u00f3n continuamente con una contrase\u00f1a incorrecta" } ], "id": "CVE-2021-20598", "lastModified": "2024-11-21T05:46:51.190", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-08-06T17:15:07.173", "references": [ { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU98578731/index.html" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-010_en.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU98578731/index.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-010_en.pdf" } ], "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }