Search criteria

6 vulnerabilities found for rx3 by tenda

CVE-2025-5527 (GCVE-0-2025-5527)

Vulnerability from cvelistv5 – Published: 2025-06-03 20:31 – Updated: 2025-06-04 13:55
VLAI?
Title
Tenda RX3 SetStaticRouteCfg save_staticroute_data stack-based overflow
Summary
A vulnerability was found in Tenda RX3 16.03.13.11_multi_TDE01. It has been rated as critical. This issue affects the function save_staticroute_data of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
https://vuldb.com/?id.310967 vdb-entrytechnical-description
https://vuldb.com/?ctiid.310967 signaturepermissions-required
https://vuldb.com/?submit.586781 third-party-advisory
https://github.com/alc9700jmo/CVE/issues/13 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda RX3 Affected: 16.03.13.11_multi_TDE01
Create a notification for this product.
Credits
alc9700 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-5527",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-04T13:55:13.106941Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-04T13:55:16.897Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/alc9700jmo/CVE/issues/13"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "RX3",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.13.11_multi_TDE01"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "alc9700 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda RX3 16.03.13.11_multi_TDE01. It has been rated as critical. This issue affects the function save_staticroute_data of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda RX3 16.03.13.11_multi_TDE01 ausgemacht. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion save_staticroute_data der Datei /goform/SetStaticRouteCfg. Durch Manipulieren des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-03T20:31:06.838Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-310967 | Tenda RX3 SetStaticRouteCfg save_staticroute_data stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.310967"
        },
        {
          "name": "VDB-310967 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.310967"
        },
        {
          "name": "Submit #586781 | Shenzhen Tenda Technology Co., Ltd. Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.586781"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/alc9700jmo/CVE/issues/13"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-06-03T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-06-03T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-06-03T15:16:45.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda RX3 SetStaticRouteCfg save_staticroute_data stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-5527",
    "datePublished": "2025-06-03T20:31:06.838Z",
    "dateReserved": "2025-06-03T13:11:39.939Z",
    "dateUpdated": "2025-06-04T13:55:16.897Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-4357 (GCVE-0-2025-4357)

Vulnerability from cvelistv5 – Published: 2025-05-06 13:31 – Updated: 2025-05-06 14:39
VLAI?
Title
Tenda RX3 telnet command injection
Summary
A vulnerability was found in Tenda RX3 16.03.13.11_multi. It has been rated as critical. This issue affects some unknown processing of the file /goform/telnet. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda RX3 Affected: 16.03.13.11_multi
Create a notification for this product.
Credits
duojie_0x00 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-4357",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-06T14:39:31.762587Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-06T14:39:36.483Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Ghostsuzhijian/Iot-/blob/main/RX3_telnetd/rx3_telnetd.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "RX3",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.13.11_multi"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "duojie_0x00 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda RX3 16.03.13.11_multi. It has been rated as critical. This issue affects some unknown processing of the file /goform/telnet. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda RX3 16.03.13.11_multi ausgemacht. Sie wurde als kritisch eingestuft. Davon betroffen ist unbekannter Code der Datei /goform/telnet. Durch die Manipulation mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5.8,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-06T13:31:07.818Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-307475 | Tenda RX3 telnet command injection",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/?id.307475"
        },
        {
          "name": "VDB-307475 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.307475"
        },
        {
          "name": "Submit #564727 | Tenda RX3 V16.03.13.11_multi  Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.564727"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Ghostsuzhijian/Iot-/blob/main/RX3_telnetd/rx3_telnetd.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-05-05T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-05-05T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-05-05T19:16:33.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda RX3 telnet command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-4357",
    "datePublished": "2025-05-06T13:31:07.818Z",
    "dateReserved": "2025-05-05T17:11:30.503Z",
    "dateUpdated": "2025-05-06T14:39:36.483Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-3259 (GCVE-0-2025-3259)

Vulnerability from cvelistv5 – Published: 2025-04-04 17:31 – Updated: 2025-04-04 18:55
VLAI?
Title
Tenda RX3 SetOnlineDevName formSetDeviceName stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda RX3 16.03.13.11. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda RX3 Affected: 16.03.13.11
Create a notification for this product.
Credits
syuvi (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3259",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-04T18:55:13.505001Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-04T18:55:17.132Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://sixth-action-50e.notion.site/Tenda-RX3-Buffer-Overflow-1c9f6468377380a2977cd6c3a81f453c"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "RX3",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.13.11"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "syuvi (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Tenda RX3 16.03.13.11. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda RX3 16.03.13.11 entdeckt. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion formSetDeviceName der Datei /goform/SetOnlineDevName. Durch Manipulation des Arguments devName mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-04T17:31:06.694Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-303329 | Tenda RX3 SetOnlineDevName formSetDeviceName stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.303329"
        },
        {
          "name": "VDB-303329 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.303329"
        },
        {
          "name": "Submit #549199 | Tenda RX3 RX3 Firmware V16.03.13.11_multi Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.549199"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://sixth-action-50e.notion.site/Tenda-RX3-Buffer-Overflow-1c9f6468377380a2977cd6c3a81f453c?pvs=4"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-04-04T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-04-04T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-04-04T09:51:50.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda RX3 SetOnlineDevName formSetDeviceName stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-3259",
    "datePublished": "2025-04-04T17:31:06.694Z",
    "dateReserved": "2025-04-04T07:46:47.401Z",
    "dateUpdated": "2025-04-04T18:55:17.132Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-5527 (GCVE-0-2025-5527)

Vulnerability from nvd – Published: 2025-06-03 20:31 – Updated: 2025-06-04 13:55
VLAI?
Title
Tenda RX3 SetStaticRouteCfg save_staticroute_data stack-based overflow
Summary
A vulnerability was found in Tenda RX3 16.03.13.11_multi_TDE01. It has been rated as critical. This issue affects the function save_staticroute_data of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
https://vuldb.com/?id.310967 vdb-entrytechnical-description
https://vuldb.com/?ctiid.310967 signaturepermissions-required
https://vuldb.com/?submit.586781 third-party-advisory
https://github.com/alc9700jmo/CVE/issues/13 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda RX3 Affected: 16.03.13.11_multi_TDE01
Create a notification for this product.
Credits
alc9700 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-5527",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-04T13:55:13.106941Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-04T13:55:16.897Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/alc9700jmo/CVE/issues/13"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "RX3",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.13.11_multi_TDE01"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "alc9700 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda RX3 16.03.13.11_multi_TDE01. It has been rated as critical. This issue affects the function save_staticroute_data of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda RX3 16.03.13.11_multi_TDE01 ausgemacht. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion save_staticroute_data der Datei /goform/SetStaticRouteCfg. Durch Manipulieren des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-03T20:31:06.838Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-310967 | Tenda RX3 SetStaticRouteCfg save_staticroute_data stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.310967"
        },
        {
          "name": "VDB-310967 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.310967"
        },
        {
          "name": "Submit #586781 | Shenzhen Tenda Technology Co., Ltd. Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.586781"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/alc9700jmo/CVE/issues/13"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-06-03T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-06-03T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-06-03T15:16:45.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda RX3 SetStaticRouteCfg save_staticroute_data stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-5527",
    "datePublished": "2025-06-03T20:31:06.838Z",
    "dateReserved": "2025-06-03T13:11:39.939Z",
    "dateUpdated": "2025-06-04T13:55:16.897Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-4357 (GCVE-0-2025-4357)

Vulnerability from nvd – Published: 2025-05-06 13:31 – Updated: 2025-05-06 14:39
VLAI?
Title
Tenda RX3 telnet command injection
Summary
A vulnerability was found in Tenda RX3 16.03.13.11_multi. It has been rated as critical. This issue affects some unknown processing of the file /goform/telnet. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda RX3 Affected: 16.03.13.11_multi
Create a notification for this product.
Credits
duojie_0x00 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-4357",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-06T14:39:31.762587Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-06T14:39:36.483Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Ghostsuzhijian/Iot-/blob/main/RX3_telnetd/rx3_telnetd.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "RX3",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.13.11_multi"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "duojie_0x00 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda RX3 16.03.13.11_multi. It has been rated as critical. This issue affects some unknown processing of the file /goform/telnet. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda RX3 16.03.13.11_multi ausgemacht. Sie wurde als kritisch eingestuft. Davon betroffen ist unbekannter Code der Datei /goform/telnet. Durch die Manipulation mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5.8,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-06T13:31:07.818Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-307475 | Tenda RX3 telnet command injection",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/?id.307475"
        },
        {
          "name": "VDB-307475 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.307475"
        },
        {
          "name": "Submit #564727 | Tenda RX3 V16.03.13.11_multi  Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.564727"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Ghostsuzhijian/Iot-/blob/main/RX3_telnetd/rx3_telnetd.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-05-05T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-05-05T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-05-05T19:16:33.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda RX3 telnet command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-4357",
    "datePublished": "2025-05-06T13:31:07.818Z",
    "dateReserved": "2025-05-05T17:11:30.503Z",
    "dateUpdated": "2025-05-06T14:39:36.483Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-3259 (GCVE-0-2025-3259)

Vulnerability from nvd – Published: 2025-04-04 17:31 – Updated: 2025-04-04 18:55
VLAI?
Title
Tenda RX3 SetOnlineDevName formSetDeviceName stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda RX3 16.03.13.11. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda RX3 Affected: 16.03.13.11
Create a notification for this product.
Credits
syuvi (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3259",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-04T18:55:13.505001Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-04T18:55:17.132Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://sixth-action-50e.notion.site/Tenda-RX3-Buffer-Overflow-1c9f6468377380a2977cd6c3a81f453c"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "RX3",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.13.11"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "syuvi (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Tenda RX3 16.03.13.11. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda RX3 16.03.13.11 entdeckt. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion formSetDeviceName der Datei /goform/SetOnlineDevName. Durch Manipulation des Arguments devName mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-04T17:31:06.694Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-303329 | Tenda RX3 SetOnlineDevName formSetDeviceName stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.303329"
        },
        {
          "name": "VDB-303329 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.303329"
        },
        {
          "name": "Submit #549199 | Tenda RX3 RX3 Firmware V16.03.13.11_multi Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.549199"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://sixth-action-50e.notion.site/Tenda-RX3-Buffer-Overflow-1c9f6468377380a2977cd6c3a81f453c?pvs=4"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-04-04T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-04-04T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-04-04T09:51:50.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda RX3 SetOnlineDevName formSetDeviceName stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-3259",
    "datePublished": "2025-04-04T17:31:06.694Z",
    "dateReserved": "2025-04-04T07:46:47.401Z",
    "dateUpdated": "2025-04-04T18:55:17.132Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}