VAR-201702-0073

Vulnerability from variot - Updated: 2023-12-18 13:24

An issue was discovered in IBHsoftec S7-SoftPLC prior to 4.12b. Object memory can read a network packet that is larger than the space that is available, a Heap-based Buffer Overflow. This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of IBHsoftec SoftPLC. Authentication is not required to exploit this vulnerability. The specific flaw exists within the processing of packets by the service listening on TCP port 502. The issue lies in the failure to properly validate the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute arbitrary code under the context of Administrator. IBHsoftec S7-SoftPLC is a software program for the replacement of hardware PLCs by IBHsoftec, Germany. Failed exploit attempts will likely cause denial-of-service conditions

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201702-0073",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "s7-softplc",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "ibhsoftec",
        "version": "4.12"
      },
      {
        "model": "s7-softplc",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "ibhsoftec",
        "version": "4.12b"
      },
      {
        "model": "s7-softplc",
        "scope": null,
        "trust": 0.7,
        "vendor": "ibhsoftec",
        "version": null
      },
      {
        "model": "s7-softplc \u003c4.12b",
        "scope": null,
        "trust": 0.6,
        "vendor": "ibhsoftec",
        "version": null
      },
      {
        "model": "s7-softplc",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "ibhsoftec",
        "version": "4.12"
      },
      {
        "model": "s7-softplc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "ibhsoftec",
        "version": "0"
      },
      {
        "model": "s7-softplc 4.12b",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "ibhsoftec",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "s7 softplc",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "6ff3299d-1fd7-4cd2-8254-80ed685ecc17"
      },
      {
        "db": "ZDI",
        "id": "ZDI-16-604"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2016-10616"
      },
      {
        "db": "BID",
        "id": "94054"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-007776"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-8364"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201610-903"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:ibhsoftec:s7-softplc:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "4.12",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2016-8364"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Ariele Caltabiano (kimiya)",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-16-604"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2016-8364",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 10.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "CVE-2016-8364",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "ZDI",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "CVE-2016-8364",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "HIGH",
            "trust": 0.7,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2016-10616",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "6ff3299d-1fd7-4cd2-8254-80ed685ecc17",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2016-8364",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2016-8364",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "ZDI",
            "id": "CVE-2016-8364",
            "trust": 0.7,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2016-10616",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201610-903",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "6ff3299d-1fd7-4cd2-8254-80ed685ecc17",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2016-8364",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "6ff3299d-1fd7-4cd2-8254-80ed685ecc17"
      },
      {
        "db": "ZDI",
        "id": "ZDI-16-604"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2016-10616"
      },
      {
        "db": "VULMON",
        "id": "CVE-2016-8364"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-007776"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-8364"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201610-903"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered in IBHsoftec S7-SoftPLC prior to 4.12b. Object memory can read a network packet that is larger than the space that is available, a Heap-based Buffer Overflow. This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of IBHsoftec SoftPLC. Authentication is not required to exploit this vulnerability. The specific flaw exists within the processing of packets by the service listening on TCP port 502. The issue lies in the failure to properly validate the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute arbitrary code under the context of Administrator. IBHsoftec S7-SoftPLC is a software program for the replacement of hardware PLCs by IBHsoftec, Germany. Failed exploit attempts will likely cause denial-of-service conditions",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2016-8364"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-007776"
      },
      {
        "db": "ZDI",
        "id": "ZDI-16-604"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2016-10616"
      },
      {
        "db": "BID",
        "id": "94054"
      },
      {
        "db": "IVD",
        "id": "6ff3299d-1fd7-4cd2-8254-80ed685ecc17"
      },
      {
        "db": "VULMON",
        "id": "CVE-2016-8364"
      }
    ],
    "trust": 3.33
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2016-8364",
        "trust": 4.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-16-306-02",
        "trust": 3.4
      },
      {
        "db": "BID",
        "id": "94054",
        "trust": 2.0
      },
      {
        "db": "CNVD",
        "id": "CNVD-2016-10616",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201610-903",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-007776",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-3832",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-16-604",
        "trust": 0.7
      },
      {
        "db": "IVD",
        "id": "6FF3299D-1FD7-4CD2-8254-80ED685ECC17",
        "trust": 0.2
      },
      {
        "db": "VULMON",
        "id": "CVE-2016-8364",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "6ff3299d-1fd7-4cd2-8254-80ed685ecc17"
      },
      {
        "db": "ZDI",
        "id": "ZDI-16-604"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2016-10616"
      },
      {
        "db": "VULMON",
        "id": "CVE-2016-8364"
      },
      {
        "db": "BID",
        "id": "94054"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-007776"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-8364"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201610-903"
      }
    ]
  },
  "id": "VAR-201702-0073",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "6ff3299d-1fd7-4cd2-8254-80ed685ecc17"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2016-10616"
      }
    ],
    "trust": 1.3833333
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "6ff3299d-1fd7-4cd2-8254-80ed685ecc17"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2016-10616"
      }
    ]
  },
  "last_update_date": "2023-12-18T13:24:31.380000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.ibhsoftec.com/"
      },
      {
        "title": "IBHsoftec has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-16-306-02"
      },
      {
        "title": "IBHsoftec S7-SoftPLC CPX43 heap buffer overflow vulnerability patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/83535"
      },
      {
        "title": "IBHsoftec S7-SoftPLC CPX43 Fixes for heap-based buffer overflow vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=65222"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-16-604"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2016-10616"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-007776"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201610-903"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-007776"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-8364"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 4.2,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-16-306-02"
      },
      {
        "trust": 1.1,
        "url": "http://www.securityfocus.com/bid/94054"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-8364"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2016-8364"
      },
      {
        "trust": 0.3,
        "url": "https://www.ibhsoftec.com/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/119.html"
      },
      {
        "trust": 0.1,
        "url": "http://tools.cisco.com/security/center/viewalert.x?alertid=49557"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-16-604"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2016-10616"
      },
      {
        "db": "VULMON",
        "id": "CVE-2016-8364"
      },
      {
        "db": "BID",
        "id": "94054"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-007776"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-8364"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201610-903"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "6ff3299d-1fd7-4cd2-8254-80ed685ecc17"
      },
      {
        "db": "ZDI",
        "id": "ZDI-16-604"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2016-10616"
      },
      {
        "db": "VULMON",
        "id": "CVE-2016-8364"
      },
      {
        "db": "BID",
        "id": "94054"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-007776"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-8364"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201610-903"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2016-11-04T00:00:00",
        "db": "IVD",
        "id": "6ff3299d-1fd7-4cd2-8254-80ed685ecc17"
      },
      {
        "date": "2016-11-08T00:00:00",
        "db": "ZDI",
        "id": "ZDI-16-604"
      },
      {
        "date": "2016-11-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2016-10616"
      },
      {
        "date": "2017-02-13T00:00:00",
        "db": "VULMON",
        "id": "CVE-2016-8364"
      },
      {
        "date": "2016-11-01T00:00:00",
        "db": "BID",
        "id": "94054"
      },
      {
        "date": "2017-03-16T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2016-007776"
      },
      {
        "date": "2017-02-13T21:59:01.110000",
        "db": "NVD",
        "id": "CVE-2016-8364"
      },
      {
        "date": "2016-11-02T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201610-903"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2016-11-08T00:00:00",
        "db": "ZDI",
        "id": "ZDI-16-604"
      },
      {
        "date": "2016-11-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2016-10616"
      },
      {
        "date": "2017-02-28T00:00:00",
        "db": "VULMON",
        "id": "CVE-2016-8364"
      },
      {
        "date": "2016-11-24T01:07:00",
        "db": "BID",
        "id": "94054"
      },
      {
        "date": "2017-03-16T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2016-007776"
      },
      {
        "date": "2017-02-28T15:59:28.017000",
        "db": "NVD",
        "id": "CVE-2016-8364"
      },
      {
        "date": "2016-11-02T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201610-903"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201610-903"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "IBHsoftec S7-SoftPLC CPX43 Heap Buffer Overflow Vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "6ff3299d-1fd7-4cd2-8254-80ed685ecc17"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2016-10616"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Buffer overflow",
    "sources": [
      {
        "db": "IVD",
        "id": "6ff3299d-1fd7-4cd2-8254-80ed685ecc17"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201610-903"
      }
    ],
    "trust": 0.8
  }
}

FKIE_CVE-2016-8364

Vulnerability from fkie_nvd - Published: 2017-02-13 21:59 - Updated: 2025-04-20 01:37
Severity ?
Summary
An issue was discovered in IBHsoftec S7-SoftPLC prior to 4.12b. Object memory can read a network packet that is larger than the space that is available, a Heap-based Buffer Overflow.
Impacted products
Vendor Product Version
ibhsoftec s7-softplc *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ibhsoftec:s7-softplc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3D726B14-E8CB-4916-A350-0E8F18E9BA3E",
              "versionEndIncluding": "4.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered in IBHsoftec S7-SoftPLC prior to 4.12b. Object memory can read a network packet that is larger than the space that is available, a Heap-based Buffer Overflow."
    },
    {
      "lang": "es",
      "value": "Ha sido descubierto un problema en IBHsoftec S7-SoftPLC anterior a la versi\u00f3n 4.12b. La memoria de objeto puede leer un paquete de red m\u00e1s grande que el espacio disponible, un desbordamiento de b\u00fafer basado en memoria din\u00e1mica."
    }
  ],
  "id": "CVE-2016-8364",
  "lastModified": "2025-04-20T01:37:25.860",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2017-02-13T21:59:01.110",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/94054"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-306-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/94054"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-306-02"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2016-8364 (GCVE-0-2016-8364)

Vulnerability from cvelistv5 – Published: 2017-02-13 21:00 – Updated: 2024-08-06 02:20
VLAI?
Summary
An issue was discovered in IBHsoftec S7-SoftPLC prior to 4.12b. Object memory can read a network packet that is larger than the space that is available, a Heap-based Buffer Overflow.
Severity ?
No CVSS data available.
CWE
  • IBHsoftec S7-SoftPLC CPX43 Heap-based Buffer Overflow Vulnerability
Assigner
References
Impacted products
Vendor Product Version
n/a IBHsoftec S7-SoftPLC CPX43 prior to 4.12b Affected: IBHsoftec S7-SoftPLC CPX43 prior to 4.12b
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T02:20:30.928Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "94054",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/94054"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-306-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "IBHsoftec S7-SoftPLC CPX43 prior to 4.12b",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "IBHsoftec S7-SoftPLC CPX43 prior to 4.12b"
            }
          ]
        }
      ],
      "datePublic": "2017-02-13T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in IBHsoftec S7-SoftPLC prior to 4.12b. Object memory can read a network packet that is larger than the space that is available, a Heap-based Buffer Overflow."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "IBHsoftec S7-SoftPLC CPX43 Heap-based Buffer Overflow Vulnerability",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-02-14T10:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "94054",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/94054"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-306-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2016-8364",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "IBHsoftec S7-SoftPLC CPX43 prior to 4.12b",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "IBHsoftec S7-SoftPLC CPX43 prior to 4.12b"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in IBHsoftec S7-SoftPLC prior to 4.12b. Object memory can read a network packet that is larger than the space that is available, a Heap-based Buffer Overflow."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IBHsoftec S7-SoftPLC CPX43 Heap-based Buffer Overflow Vulnerability"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "94054",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/94054"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-306-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-306-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2016-8364",
    "datePublished": "2017-02-13T21:00:00",
    "dateReserved": "2016-09-28T00:00:00",
    "dateUpdated": "2024-08-06T02:20:30.928Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2016-8364 (GCVE-0-2016-8364)

Vulnerability from nvd – Published: 2017-02-13 21:00 – Updated: 2024-08-06 02:20
VLAI?
Summary
An issue was discovered in IBHsoftec S7-SoftPLC prior to 4.12b. Object memory can read a network packet that is larger than the space that is available, a Heap-based Buffer Overflow.
Severity ?
No CVSS data available.
CWE
  • IBHsoftec S7-SoftPLC CPX43 Heap-based Buffer Overflow Vulnerability
Assigner
References
Impacted products
Vendor Product Version
n/a IBHsoftec S7-SoftPLC CPX43 prior to 4.12b Affected: IBHsoftec S7-SoftPLC CPX43 prior to 4.12b
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T02:20:30.928Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "94054",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/94054"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-306-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "IBHsoftec S7-SoftPLC CPX43 prior to 4.12b",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "IBHsoftec S7-SoftPLC CPX43 prior to 4.12b"
            }
          ]
        }
      ],
      "datePublic": "2017-02-13T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in IBHsoftec S7-SoftPLC prior to 4.12b. Object memory can read a network packet that is larger than the space that is available, a Heap-based Buffer Overflow."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "IBHsoftec S7-SoftPLC CPX43 Heap-based Buffer Overflow Vulnerability",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-02-14T10:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "94054",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/94054"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-306-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2016-8364",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "IBHsoftec S7-SoftPLC CPX43 prior to 4.12b",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "IBHsoftec S7-SoftPLC CPX43 prior to 4.12b"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in IBHsoftec S7-SoftPLC prior to 4.12b. Object memory can read a network packet that is larger than the space that is available, a Heap-based Buffer Overflow."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IBHsoftec S7-SoftPLC CPX43 Heap-based Buffer Overflow Vulnerability"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "94054",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/94054"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-306-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-306-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2016-8364",
    "datePublished": "2017-02-13T21:00:00",
    "dateReserved": "2016-09-28T00:00:00",
    "dateUpdated": "2024-08-06T02:20:30.928Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}