All the vulnerabilites related to siemens - simatic_ipc227g_firmware
cve-2021-42554
Vulnerability from cvelistv5
Published
2022-02-03 01:40
Modified
2024-08-04 03:38
Severity ?
EPSS score ?
Summary
An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
References
▼ | URL | Tags |
---|---|---|
https://www.insyde.com/security-pledge | x_refsource_MISC | |
https://www.insyde.com/security-pledge/SA-2022012 | x_refsource_MISC | |
https://security.netapp.com/advisory/ntap-20220216-0007/ | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T03:38:49.251Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.insyde.com/security-pledge" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.insyde.com/security-pledge/SA-2022012" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20220216-0007/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-22T19:06:40", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.insyde.com/security-pledge" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.insyde.com/security-pledge/SA-2022012" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://security.netapp.com/advisory/ntap-20220216-0007/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-42554", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.insyde.com/security-pledge", "refsource": "MISC", "url": "https://www.insyde.com/security-pledge" }, { "name": "https://www.insyde.com/security-pledge/SA-2022012", "refsource": "MISC", "url": "https://www.insyde.com/security-pledge/SA-2022012" }, { "name": "https://security.netapp.com/advisory/ntap-20220216-0007/", "refsource": "CONFIRM", "url": "https://security.netapp.com/advisory/ntap-20220216-0007/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-42554", "datePublished": "2022-02-03T01:40:56", "dateReserved": "2021-10-18T00:00:00", "dateUpdated": "2024-08-04T03:38:49.251Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-41838
Vulnerability from cvelistv5
Published
2022-02-03 01:43
Modified
2024-08-04 03:22
Severity ?
EPSS score ?
Summary
An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check.
References
▼ | URL | Tags |
---|---|---|
https://www.insyde.com/security-pledge | x_refsource_MISC | |
https://www.insyde.com/security-pledge/SA-2022023 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | x_refsource_CONFIRM | |
https://security.netapp.com/advisory/ntap-20220222-0001/ | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T03:22:24.937Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.insyde.com/security-pledge" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.insyde.com/security-pledge/SA-2022023" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20220222-0001/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-23T15:06:23", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.insyde.com/security-pledge" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.insyde.com/security-pledge/SA-2022023" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://security.netapp.com/advisory/ntap-20220222-0001/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-41838", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.insyde.com/security-pledge", "refsource": "MISC", "url": "https://www.insyde.com/security-pledge" }, { "name": "https://www.insyde.com/security-pledge/SA-2022023", "refsource": "MISC", "url": "https://www.insyde.com/security-pledge/SA-2022023" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "name": "https://security.netapp.com/advisory/ntap-20220222-0001/", "refsource": "CONFIRM", "url": "https://security.netapp.com/advisory/ntap-20220222-0001/" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-41838", "datePublished": "2022-02-03T01:43:30", "dateReserved": "2021-10-01T00:00:00", "dateUpdated": "2024-08-04T03:22:24.937Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-5953
Vulnerability from cvelistv5
Published
2022-02-03 01:00
Modified
2024-08-04 08:47
Severity ?
EPSS score ?
Summary
A vulnerability exists in System Management Interrupt (SWSMI) handler of InsydeH2O UEFI Firmware code located in SWSMI handler that dereferences gRT (EFI_RUNTIME_SERVICES) pointer to call a GetVariable service, which is located outside of SMRAM. This can result in code execution in SMM (escalating privilege from ring 0 to ring -2).
References
▼ | URL | Tags |
---|---|---|
https://www.insyde.com/products | x_refsource_MISC | |
https://www.insyde.com/security-pledge | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | x_refsource_CONFIRM | |
https://security.netapp.com/advisory/ntap-20220222-0005/ | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T08:47:41.026Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.insyde.com/products" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.insyde.com/security-pledge" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20220222-0005/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability exists in System Management Interrupt (SWSMI) handler of InsydeH2O UEFI Firmware code located in SWSMI handler that dereferences gRT (EFI_RUNTIME_SERVICES) pointer to call a GetVariable service, which is located outside of SMRAM. This can result in code execution in SMM (escalating privilege from ring 0 to ring -2)." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-23T15:06:21", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.insyde.com/products" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.insyde.com/security-pledge" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://security.netapp.com/advisory/ntap-20220222-0005/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-5953", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability exists in System Management Interrupt (SWSMI) handler of InsydeH2O UEFI Firmware code located in SWSMI handler that dereferences gRT (EFI_RUNTIME_SERVICES) pointer to call a GetVariable service, which is located outside of SMRAM. This can result in code execution in SMM (escalating privilege from ring 0 to ring -2)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.insyde.com/products", "refsource": "MISC", "url": "https://www.insyde.com/products" }, { "name": "https://www.insyde.com/security-pledge", "refsource": "MISC", "url": "https://www.insyde.com/security-pledge" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "name": "https://security.netapp.com/advisory/ntap-20220222-0005/", "refsource": "CONFIRM", "url": "https://security.netapp.com/advisory/ntap-20220222-0005/" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-5953", "datePublished": "2022-02-03T01:00:57", "dateReserved": "2020-01-06T00:00:00", "dateUpdated": "2024-08-04T08:47:41.026Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-41837
Vulnerability from cvelistv5
Published
2022-02-03 01:23
Modified
2024-08-04 03:22
Severity ?
EPSS score ?
Summary
An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
References
▼ | URL | Tags |
---|---|---|
https://www.insyde.com/security-pledge | x_refsource_MISC | |
https://www.insyde.com/security-pledge/SA-2022024 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | x_refsource_CONFIRM | |
https://security.netapp.com/advisory/ntap-20220222-0003/ | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T03:22:25.091Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.insyde.com/security-pledge" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.insyde.com/security-pledge/SA-2022024" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20220222-0003/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-23T15:06:18", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.insyde.com/security-pledge" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.insyde.com/security-pledge/SA-2022024" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://security.netapp.com/advisory/ntap-20220222-0003/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-41837", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.insyde.com/security-pledge", "refsource": "MISC", "url": "https://www.insyde.com/security-pledge" }, { "name": "https://www.insyde.com/security-pledge/SA-2022024", "refsource": "MISC", "url": "https://www.insyde.com/security-pledge/SA-2022024" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "name": "https://security.netapp.com/advisory/ntap-20220222-0003/", "refsource": "CONFIRM", "url": "https://security.netapp.com/advisory/ntap-20220222-0003/" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-41837", "datePublished": "2022-02-03T01:23:39", "dateReserved": "2021-10-01T00:00:00", "dateUpdated": "2024-08-04T03:22:25.091Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-33627
Vulnerability from cvelistv5
Published
2022-02-03 01:30
Modified
2024-08-03 23:58
Severity ?
EPSS score ?
Summary
An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.09.11, 5.1 before 05.17.11, 5.2 before 05.27.11, 5.3 before 05.36.11, 5.4 before 05.44.11, and 5.5 before 05.52.11 affecting FwBlockServiceSmm. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:58:21.427Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.insyde.com/security-pledge" }, { "tags": [ "x_transferred" ], "url": "https://www.insyde.com/security-pledge/SA-2022022" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "tags": [ "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20220222-0002/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.09.11, 5.1 before 05.17.11, 5.2 before 05.27.11, 5.3 before 05.36.11, 5.4 before 05.44.11, and 5.5 before 05.52.11 affecting FwBlockServiceSmm. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-22T16:50:10.835493", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.insyde.com/security-pledge" }, { "url": "https://www.insyde.com/security-pledge/SA-2022022" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "url": "https://security.netapp.com/advisory/ntap-20220222-0002/" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-33627", "datePublished": "2022-02-03T01:30:36", "dateReserved": "2021-05-28T00:00:00", "dateUpdated": "2024-08-03T23:58:21.427Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-42059
Vulnerability from cvelistv5
Published
2022-02-03 01:13
Modified
2024-08-04 03:22
Severity ?
EPSS score ?
Summary
An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.08.41, Kernel 5.1 before 05.16.41, Kernel 5.2 before 05.26.41, Kernel 5.3 before 05.35.41, and Kernel 5.4 before 05.42.20. A stack-based buffer overflow leads toarbitrary code execution in UEFI DisplayTypeDxe DXE driver.
References
▼ | URL | Tags |
---|---|---|
https://www.insyde.com/security-pledge | x_refsource_MISC | |
https://www.insyde.com/security-pledge/SA-2022006 | x_refsource_MISC | |
https://security.netapp.com/advisory/ntap-20220216-0008/ | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T03:22:25.776Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.insyde.com/security-pledge" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.insyde.com/security-pledge/SA-2022006" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20220216-0008/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.08.41, Kernel 5.1 before 05.16.41, Kernel 5.2 before 05.26.41, Kernel 5.3 before 05.35.41, and Kernel 5.4 before 05.42.20. A stack-based buffer overflow leads toarbitrary code execution in UEFI DisplayTypeDxe DXE driver." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-22T19:06:27", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.insyde.com/security-pledge" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.insyde.com/security-pledge/SA-2022006" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://security.netapp.com/advisory/ntap-20220216-0008/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-42059", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.08.41, Kernel 5.1 before 05.16.41, Kernel 5.2 before 05.26.41, Kernel 5.3 before 05.35.41, and Kernel 5.4 before 05.42.20. A stack-based buffer overflow leads toarbitrary code execution in UEFI DisplayTypeDxe DXE driver." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.insyde.com/security-pledge", "refsource": "MISC", "url": "https://www.insyde.com/security-pledge" }, { "name": "https://www.insyde.com/security-pledge/SA-2022006", "refsource": "MISC", "url": "https://www.insyde.com/security-pledge/SA-2022006" }, { "name": "https://security.netapp.com/advisory/ntap-20220216-0008/", "refsource": "CONFIRM", "url": "https://security.netapp.com/advisory/ntap-20220216-0008/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-42059", "datePublished": "2022-02-03T01:13:47", "dateReserved": "2021-10-07T00:00:00", "dateUpdated": "2024-08-04T03:22:25.776Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-33626
Vulnerability from cvelistv5
Published
2021-10-01 02:21
Modified
2024-08-03 23:58
Severity ?
EPSS score ?
Summary
A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution.
References
▼ | URL | Tags |
---|---|---|
https://www.insyde.com/security-pledge | x_refsource_MISC | |
https://www.insyde.com/security-pledge/SA-2021001 | x_refsource_MISC | |
https://security.netapp.com/advisory/ntap-20220216-0006/ | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:58:21.523Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.insyde.com/security-pledge" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.insyde.com/security-pledge/SA-2021001" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20220216-0006/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-22T19:07:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.insyde.com/security-pledge" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.insyde.com/security-pledge/SA-2021001" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://security.netapp.com/advisory/ntap-20220216-0006/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" } ], "source": { "discovery": "INTERNAL" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-33626", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.insyde.com/security-pledge", "refsource": "MISC", "url": "https://www.insyde.com/security-pledge" }, { "name": "https://www.insyde.com/security-pledge/SA-2021001", "refsource": "MISC", "url": "https://www.insyde.com/security-pledge/SA-2021001" }, { "name": "https://security.netapp.com/advisory/ntap-20220216-0006/", "refsource": "CONFIRM", "url": "https://security.netapp.com/advisory/ntap-20220216-0006/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" } ] }, "source": { "discovery": "INTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-33626", "datePublished": "2021-10-01T02:21:29", "dateReserved": "2021-05-28T00:00:00", "dateUpdated": "2024-08-03T23:58:21.523Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-33625
Vulnerability from cvelistv5
Published
2022-02-03 01:55
Modified
2024-08-03 23:58
Severity ?
EPSS score ?
Summary
An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.
References
▼ | URL | Tags |
---|---|---|
https://www.insyde.com/security-pledge | x_refsource_MISC | |
https://www.insyde.com/security-pledge/SA-2022014 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | x_refsource_CONFIRM | |
https://security.netapp.com/advisory/ntap-20220222-0004/ | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:58:21.414Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.insyde.com/security-pledge" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.insyde.com/security-pledge/SA-2022014" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20220222-0004/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-23T15:06:25", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.insyde.com/security-pledge" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.insyde.com/security-pledge/SA-2022014" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://security.netapp.com/advisory/ntap-20220222-0004/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-33625", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.insyde.com/security-pledge", "refsource": "MISC", "url": "https://www.insyde.com/security-pledge" }, { "name": "https://www.insyde.com/security-pledge/SA-2022014", "refsource": "MISC", "url": "https://www.insyde.com/security-pledge/SA-2022014" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "name": "https://security.netapp.com/advisory/ntap-20220222-0004/", "refsource": "CONFIRM", "url": "https://security.netapp.com/advisory/ntap-20220222-0004/" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-33625", "datePublished": "2022-02-03T01:55:10", "dateReserved": "2021-05-28T00:00:00", "dateUpdated": "2024-08-03T23:58:21.414Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-27339
Vulnerability from cvelistv5
Published
2021-06-16 15:49
Modified
2024-08-04 16:11
Severity ?
EPSS score ?
Summary
In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5).
References
▼ | URL | Tags |
---|---|---|
https://www.insyde.com/security-pledge/SA-2021001 | x_refsource_MISC | |
https://security.netapp.com/advisory/ntap-20220216-0005/ | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:11:36.601Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.insyde.com/security-pledge/SA-2021001" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20220216-0005/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5)." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-22T19:07:12", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.insyde.com/security-pledge/SA-2021001" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://security.netapp.com/advisory/ntap-20220216-0005/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-27339", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.insyde.com/security-pledge/SA-2021001", "refsource": "MISC", "url": "https://www.insyde.com/security-pledge/SA-2021001" }, { "name": "https://security.netapp.com/advisory/ntap-20220216-0005/", "refsource": "CONFIRM", "url": "https://security.netapp.com/advisory/ntap-20220216-0005/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-27339", "datePublished": "2021-06-16T15:49:34", "dateReserved": "2020-10-20T00:00:00", "dateUpdated": "2024-08-04T16:11:36.601Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2022-02-03 02:15
Modified
2024-11-21 06:27
Severity ?
Summary
An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.08.41, Kernel 5.1 before 05.16.41, Kernel 5.2 before 05.26.41, Kernel 5.3 before 05.35.41, and Kernel 5.4 before 05.42.20. A stack-based buffer overflow leads toarbitrary code execution in UEFI DisplayTypeDxe DXE driver.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | Third Party Advisory | |
cve@mitre.org | https://security.netapp.com/advisory/ntap-20220216-0008/ | Third Party Advisory | |
cve@mitre.org | https://www.insyde.com/security-pledge | Vendor Advisory | |
cve@mitre.org | https://www.insyde.com/security-pledge/SA-2022006 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://security.netapp.com/advisory/ntap-20220216-0008/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.insyde.com/security-pledge | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.insyde.com/security-pledge/SA-2022006 | Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "A64DE17F-735B-490B-A4AD-8606684DDB5D", "versionEndExcluding": "5.08.41", "versionStartIncluding": "5.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "5EE9D6D0-77EF-41CE-ACB2-A43B0543F9C7", "versionEndExcluding": "5.16.41", "versionStartIncluding": "5.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "ADDAD8E2-7468-4D96-8A9F-8C2BB0E8EACB", "versionEndExcluding": "5.26.41", "versionStartIncluding": "5.2", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "7AF0CD01-CD57-41D5-9827-437F0683E13B", "versionEndExcluding": "5.35.41", "versionStartIncluding": "5.3", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "612CCC25-B065-44F6-A531-E310A2A1B9A6", "versionEndExcluding": "5.42.20", "versionStartIncluding": "5.4", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "324ADC7E-AECD-4B7D-8571-5399542C2BF6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*", "matchCriteriaId": "506DEE00-30D2-4E29-9645-757EB8778C0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "480C5657-5C05-40F5-B76A-E67119727ED8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F3C3E60-7C36-4F5D-B454-97C9D0FD9459", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc127e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2AEB5AD1-3973-4150-BEA2-C9DE0B98222F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*", "matchCriteriaId": "F63C0B17-60E2-4240-92FD-4B7C7D8F2C8B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc227g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C3F52F29-0ACF-4ECC-927A-0CB27399E5D9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc227g:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D1E85AC-1305-4C5E-AD8B-39B2654F6057", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc277g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F203C449-2B5C-47A1-BF3D-8DCFD29F0B18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc277g:-:*:*:*:*:*:*:*", "matchCriteriaId": "320F5752-86B3-4C08-89D0-02272753A6D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc327g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A37FB5EC-BB64-472C-81FC-8EEF238E3C12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc327g:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC7303D1-CC95-42C7-B843-C3B3B3336669", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc377g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "45013BCA-3897-4D58-81FA-D8CB9D19268C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc377g:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDD6F034-BC50-4223-AE5D-319F04C866A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F6422BF3-01B7-443B-BD2B-80E45D7C3F5F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*", "matchCriteriaId": "A40D0CDB-7BE6-491F-B730-3B4E10CA159A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "696F47E6-C1CA-4A58-A91F-4B3EA92954AF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDF9D4C3-1892-48FA-95B4-835B636A4005", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc627e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F712060C-ECDB-4BC7-B9B9-468B41DE615B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9AF082-8345-4BE1-B1FC-6E0316BB833B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc647e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D511C170-65E5-416D-B7CE-557A503F25AE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*", "matchCriteriaId": "E430C4C5-D887-47C6-B50F-66EEE9519151", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc677e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "577C19F5-82ED-46DF-91CC-A074DE99EBDD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc677e:-:*:*:*:*:*:*:*", "matchCriteriaId": "5F9FA42D-B2F0-456F-89B7-6A5789787FBA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc847e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CEF4592C-5DB3-45F4-B354-59701BBA0C08", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*", "matchCriteriaId": "1157418C-14C4-43C4-B63E-7E98D868A94F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "87F0538B-ED6E-40C7-9C2A-4C5DC3D2935E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "187C6D51-5B86-484D-AE0F-26D1C9465580", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.08.41, Kernel 5.1 before 05.16.41, Kernel 5.2 before 05.26.41, Kernel 5.3 before 05.35.41, and Kernel 5.4 before 05.42.20. A stack-based buffer overflow leads toarbitrary code execution in UEFI DisplayTypeDxe DXE driver." }, { "lang": "es", "value": "Se ha descubierto un problema en el Kernel versi\u00f3n 5.0 de InsydeH2O antes de 05.08.41, el Kernel versi\u00f3n 5.1 antes de 05.16.41, el Kernel versi\u00f3n 5.2 antes de 05.26.41, el Kernel versi\u00f3n 5.3 antes de 05.35.41 y el Kernel versi\u00f3n 5.4 antes de 05.42.20. Un desbordamiento del b\u00fafer basado en la pila conduce a la ejecuci\u00f3n de c\u00f3digo arbitrario en el controlador UEFI DisplayTypeDxe DXE" } ], "id": "CVE-2021-42059", "lastModified": "2024-11-21T06:27:09.830", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-02-03T02:15:07.250", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20220216-0008/" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge/SA-2022006" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20220216-0008/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge/SA-2022006" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-02-03 02:15
Modified
2024-11-21 06:09
Severity ?
Summary
An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | Third Party Advisory | |
cve@mitre.org | https://security.netapp.com/advisory/ntap-20220222-0004/ | Third Party Advisory | |
cve@mitre.org | https://www.insyde.com/security-pledge | Vendor Advisory | |
cve@mitre.org | https://www.insyde.com/security-pledge/SA-2022014 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://security.netapp.com/advisory/ntap-20220222-0004/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.insyde.com/security-pledge | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.insyde.com/security-pledge/SA-2022014 | Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "8C029DED-CC74-4AFB-B5D0-C1FD8237DCAE", "versionEndExcluding": "5.16.23", "versionStartIncluding": "5.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "AC748480-3FCF-4F8B-A726-C1DDEA3C78A0", "versionEndExcluding": "5.26.23", "versionStartIncluding": "5.2", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "C88BDB9B-D893-47BA-901C-F2055B6F4A89", "versionEndExcluding": "5.35.23", "versionStartIncluding": "5.3", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "83CE2E33-8206-4C9E-8EFF-2AAF68E61A73", "versionEndExcluding": "5.43.22", "versionStartIncluding": "5.4", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "5EE863B3-76C2-499F-8A9E-71C1169DC0F0", "versionEndExcluding": "5.51.22", "versionStartIncluding": "5.5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netapp:fas\\/aff_bios:-:*:*:*:*:*:*:*", "matchCriteriaId": "A714C8D4-9623-43C0-8AF8-8904566AD42C", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ruggedcom_ape1808_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "37FDCA69-9049-40B4-88AF-F476901022B6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ruggedcom_ape1808:-:*:*:*:*:*:*:*", "matchCriteriaId": "B89A6863-B602-4404-8D26-337FECABFFF0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "75AE72A3-05C6-4564-81CC-67865D03D106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*", "matchCriteriaId": "506DEE00-30D2-4E29-9645-757EB8778C0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc127e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "846EE524-BC53-4DE5-81C5-6B5EB2DD8BEA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*", "matchCriteriaId": "F63C0B17-60E2-4240-92FD-4B7C7D8F2C8B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_itp1000_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "64538703-AE66-4D4A-B4A1-C88039B9543D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "187C6D51-5B86-484D-AE0F-26D1C9465580", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc277g_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1865061F-CF02-410B-B01B-2088F7104867", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc277g:-:*:*:*:*:*:*:*", "matchCriteriaId": "320F5752-86B3-4C08-89D0-02272753A6D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc227g_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "2ED11E5B-E60C-4359-B87C-E373DED77677", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc227g:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D1E85AC-1305-4C5E-AD8B-39B2654F6057", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc327g_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "68215EEF-243A-4B02-BEAB-C162A3564D60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc327g:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC7303D1-CC95-42C7-B843-C3B3B3336669", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc377g_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "62751FE8-48D7-4D7B-A7DD-4977DE539660", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc377g:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDD6F034-BC50-4223-AE5D-319F04C866A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc427e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "4EC3A82C-1380-4B21-BB17-3760A0B6A027", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*", "matchCriteriaId": "A40D0CDB-7BE6-491F-B730-3B4E10CA159A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2558478-44E0-4D42-A6DC-D4262D15A92A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDF9D4C3-1892-48FA-95B4-835B636A4005", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_pro_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "6AD30972-8CE2-46B4-A4B8-B209F6B616AC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc477e_pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "3FC5CE20-7D08-4496-A857-C3A4BD0AB1AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc627e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "EFFA7953-DC4C-489A-B5A4-B832FAF3C143", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9AF082-8345-4BE1-B1FC-6E0316BB833B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc647e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "0AC414E9-5DBD-4D60-B0EA-6FB48207B628", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*", "matchCriteriaId": "E430C4C5-D887-47C6-B50F-66EEE9519151", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc677e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "193BF353-5D85-4F2E-94D0-329ED823FF07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc677e:-:*:*:*:*:*:*:*", "matchCriteriaId": "5F9FA42D-B2F0-456F-89B7-6A5789787FBA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc847e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "D8CE311F-98F9-4E58-9E52-BAFAF87C0819", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*", "matchCriteriaId": "1157418C-14C4-43C4-B63E-7E98D868A94F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "ECC5341D-9982-4F18-9C8D-2912DDB8EF9A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F3C3E60-7C36-4F5D-B454-97C9D0FD9459", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses." }, { "lang": "es", "value": "Se ha descubierto un problema en el Kernel versi\u00f3n 5.x de InsydeH2O, que afecta a HddPassword. Los servicios SMI de software que utilizan la funci\u00f3n Communicate() del EFI_SMM_COMMUNICATION_PROTOCOL no comprueban si la direcci\u00f3n del b\u00fafer es v\u00e1lida, lo que permite el uso de direcciones de SMRAM, MMIO o del n\u00facleo del SO" } ], "id": "CVE-2021-33625", "lastModified": "2024-11-21T06:09:13.220", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 6.9, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.4, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-02-03T02:15:06.930", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20220222-0004/" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge/SA-2022014" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20220222-0004/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge/SA-2022014" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-02-03 02:15
Modified
2024-11-21 06:27
Severity ?
Summary
An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | Third Party Advisory | |
cve@mitre.org | https://security.netapp.com/advisory/ntap-20220216-0007/ | Third Party Advisory | |
cve@mitre.org | https://www.insyde.com/security-pledge | Vendor Advisory | |
cve@mitre.org | https://www.insyde.com/security-pledge/SA-2022012 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://security.netapp.com/advisory/ntap-20220216-0007/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.insyde.com/security-pledge | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.insyde.com/security-pledge/SA-2022012 | Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "F0BA9E3E-930F-4EE7-B652-8746B2E3D7EE", "versionEndExcluding": "5.08.42", "versionStartIncluding": "5.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "A4803E0A-D93A-4863-B9F6-378C3D73F743", "versionEndExcluding": "5.16.42", "versionStartIncluding": "5.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "65D09B40-7B64-4890-AEA5-AE1EB5201CA1", "versionEndExcluding": "5.26.42", "versionStartIncluding": "5.2", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "E38FAADD-CEC5-421F-BBD7-1152B95B2A10", "versionEndExcluding": "5.35.42", "versionStartIncluding": "5.3", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "5536AD0D-EE19-41C7-BC57-69EAF77D6E8C", "versionEndExcluding": "5.42.51", "versionStartIncluding": "5.4", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "C140942E-1DC5-4491-8BB6-7FF6960A216D", "versionEndExcluding": "5.50.51", "versionStartIncluding": "5.5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "324ADC7E-AECD-4B7D-8571-5399542C2BF6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*", "matchCriteriaId": "506DEE00-30D2-4E29-9645-757EB8778C0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "480C5657-5C05-40F5-B76A-E67119727ED8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F3C3E60-7C36-4F5D-B454-97C9D0FD9459", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc127e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2AEB5AD1-3973-4150-BEA2-C9DE0B98222F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*", "matchCriteriaId": "F63C0B17-60E2-4240-92FD-4B7C7D8F2C8B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc227g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C3F52F29-0ACF-4ECC-927A-0CB27399E5D9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc227g:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D1E85AC-1305-4C5E-AD8B-39B2654F6057", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc277g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F203C449-2B5C-47A1-BF3D-8DCFD29F0B18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc277g:-:*:*:*:*:*:*:*", "matchCriteriaId": "320F5752-86B3-4C08-89D0-02272753A6D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc327g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A37FB5EC-BB64-472C-81FC-8EEF238E3C12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc327g:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC7303D1-CC95-42C7-B843-C3B3B3336669", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc377g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "45013BCA-3897-4D58-81FA-D8CB9D19268C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc377g:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDD6F034-BC50-4223-AE5D-319F04C866A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F6422BF3-01B7-443B-BD2B-80E45D7C3F5F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*", "matchCriteriaId": "A40D0CDB-7BE6-491F-B730-3B4E10CA159A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "696F47E6-C1CA-4A58-A91F-4B3EA92954AF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDF9D4C3-1892-48FA-95B4-835B636A4005", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc627e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F712060C-ECDB-4BC7-B9B9-468B41DE615B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9AF082-8345-4BE1-B1FC-6E0316BB833B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc647e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D511C170-65E5-416D-B7CE-557A503F25AE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*", "matchCriteriaId": "E430C4C5-D887-47C6-B50F-66EEE9519151", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc677e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "577C19F5-82ED-46DF-91CC-A074DE99EBDD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc677e:-:*:*:*:*:*:*:*", "matchCriteriaId": "5F9FA42D-B2F0-456F-89B7-6A5789787FBA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc847e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CEF4592C-5DB3-45F4-B354-59701BBA0C08", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*", "matchCriteriaId": "1157418C-14C4-43C4-B63E-7E98D868A94F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "87F0538B-ED6E-40C7-9C2A-4C5DC3D2935E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "187C6D51-5B86-484D-AE0F-26D1C9465580", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ruggedcom_ape1808_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ABE0A54C-AEB3-4B1D-AD5D-F9239709B052", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ruggedcom_ape1808:-:*:*:*:*:*:*:*", "matchCriteriaId": "B89A6863-B602-4404-8D26-337FECABFFF0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM." }, { "lang": "es", "value": "Se ha descubierto un problema en InsydeH2O con el Kernel versi\u00f3n 5.0 antes de 05.08.42, el Kernel 5.1 antes de 05.16.42, el Kernel versi\u00f3n 5.2 antes de 05.26.42, el Kernel versi\u00f3n 5.3 antes de 05.35.42, el Kernel versi\u00f3n 5.4 antes de 05.42.51 y el Kernel versi\u00f3n 5.5 antes de 05.50.51. Una vulnerabilidad de corrupci\u00f3n de memoria SMM en FvbServicesRuntimeDxe permite a un posible atacante escribir datos fijos o predecibles en la SMRAM. La explotaci\u00f3n de este problema podr\u00eda llevar a escalar privilegios a SMM." } ], "id": "CVE-2021-42554", "lastModified": "2024-11-21T06:27:47.840", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.5, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-02-03T02:15:07.380", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20220216-0007/" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge/SA-2022012" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20220216-0007/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge/SA-2022012" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-02-03 01:15
Modified
2024-11-21 05:34
Severity ?
Summary
A vulnerability exists in System Management Interrupt (SWSMI) handler of InsydeH2O UEFI Firmware code located in SWSMI handler that dereferences gRT (EFI_RUNTIME_SERVICES) pointer to call a GetVariable service, which is located outside of SMRAM. This can result in code execution in SMM (escalating privilege from ring 0 to ring -2).
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | Third Party Advisory | |
cve@mitre.org | https://security.netapp.com/advisory/ntap-20220222-0005/ | Third Party Advisory | |
cve@mitre.org | https://www.insyde.com/products | Product, Vendor Advisory | |
cve@mitre.org | https://www.insyde.com/security-pledge | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://security.netapp.com/advisory/ntap-20220222-0005/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.insyde.com/products | Product, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.insyde.com/security-pledge | Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:5.12.09.0074:*:*:*:*:*:*:*", "matchCriteriaId": "1506F007-8D5A-4F89-9C20-39C956E5E330", "vulnerable": true }, { "criteria": "cpe:2.3:a:insyde:insydeh2o:5.23.04.0045:*:*:*:*:*:*:*", "matchCriteriaId": "0D71B9DC-9A25-4395-9369-E746B0BCFAD5", "vulnerable": true }, { "criteria": "cpe:2.3:a:insyde:insydeh2o:5.23.45.0023:*:*:*:*:*:*:*", "matchCriteriaId": "DB7F094E-CE8C-44EB-AA8F-04FE034C0D02", "vulnerable": true }, { "criteria": "cpe:2.3:a:insyde:insydeh2o:5.33.15.0034:*:*:*:*:*:*:*", "matchCriteriaId": "7F636FC4-E44B-49ED-96E4-BF7187F3344C", "vulnerable": true }, { "criteria": "cpe:2.3:a:insyde:insydeh2o:5.34.03.0029:*:*:*:*:*:*:*", "matchCriteriaId": "D24FF36C-7E38-4EAA-80B2-299AF22619FF", "vulnerable": true }, { "criteria": "cpe:2.3:a:insyde:insydeh2o:5.42.03.0010:*:*:*:*:*:*:*", "matchCriteriaId": "8822BCEE-BFF7-4691-A0F0-C2CB04BE2354", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ruggedcom_ape1808_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "37FDCA69-9049-40B4-88AF-F476901022B6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ruggedcom_ape1808:-:*:*:*:*:*:*:*", "matchCriteriaId": "B89A6863-B602-4404-8D26-337FECABFFF0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "ECC5341D-9982-4F18-9C8D-2912DDB8EF9A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F3C3E60-7C36-4F5D-B454-97C9D0FD9459", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc127e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "846EE524-BC53-4DE5-81C5-6B5EB2DD8BEA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*", "matchCriteriaId": "F63C0B17-60E2-4240-92FD-4B7C7D8F2C8B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc227g_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "2ED11E5B-E60C-4359-B87C-E373DED77677", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc227g:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D1E85AC-1305-4C5E-AD8B-39B2654F6057", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc277g_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1865061F-CF02-410B-B01B-2088F7104867", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc277g:-:*:*:*:*:*:*:*", "matchCriteriaId": "320F5752-86B3-4C08-89D0-02272753A6D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_itp1000_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "64538703-AE66-4D4A-B4A1-C88039B9543D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "187C6D51-5B86-484D-AE0F-26D1C9465580", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_pro_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "6AD30972-8CE2-46B4-A4B8-B209F6B616AC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc477e_pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "3FC5CE20-7D08-4496-A857-C3A4BD0AB1AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc627e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "EFFA7953-DC4C-489A-B5A4-B832FAF3C143", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9AF082-8345-4BE1-B1FC-6E0316BB833B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc647e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "0AC414E9-5DBD-4D60-B0EA-6FB48207B628", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*", "matchCriteriaId": "E430C4C5-D887-47C6-B50F-66EEE9519151", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc677e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "193BF353-5D85-4F2E-94D0-329ED823FF07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc677e:-:*:*:*:*:*:*:*", "matchCriteriaId": "5F9FA42D-B2F0-456F-89B7-6A5789787FBA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc847e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "D8CE311F-98F9-4E58-9E52-BAFAF87C0819", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*", "matchCriteriaId": "1157418C-14C4-43C4-B63E-7E98D868A94F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc327g_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "68215EEF-243A-4B02-BEAB-C162A3564D60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc327g:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC7303D1-CC95-42C7-B843-C3B3B3336669", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc377g_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "62751FE8-48D7-4D7B-A7DD-4977DE539660", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc377g:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDD6F034-BC50-4223-AE5D-319F04C866A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc427e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "4EC3A82C-1380-4B21-BB17-3760A0B6A027", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*", "matchCriteriaId": "A40D0CDB-7BE6-491F-B730-3B4E10CA159A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2558478-44E0-4D42-A6DC-D4262D15A92A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDF9D4C3-1892-48FA-95B4-835B636A4005", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "75AE72A3-05C6-4564-81CC-67865D03D106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*", "matchCriteriaId": "506DEE00-30D2-4E29-9645-757EB8778C0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability exists in System Management Interrupt (SWSMI) handler of InsydeH2O UEFI Firmware code located in SWSMI handler that dereferences gRT (EFI_RUNTIME_SERVICES) pointer to call a GetVariable service, which is located outside of SMRAM. This can result in code execution in SMM (escalating privilege from ring 0 to ring -2)." }, { "lang": "es", "value": "Se presenta una vulnerabilidad en el manejador de Interrupciones de administraci\u00f3n del Sistema (SWSMI) del c\u00f3digo del Firmware UEFI de InsydeH2O ubicado en el manejador SWSMI que desreferencia el puntero gRT (EFI_RUNTIME_SERVICES) para llamar a un servicio GetVariable, que es encontrado fuera de la SMRAM. Esto puede resultar en una ejecuci\u00f3n de c\u00f3digo en SMM (escalando el privilegio del anillo 0 al anillo -2)" } ], "id": "CVE-2020-5953", "lastModified": "2024-11-21T05:34:53.567", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 6.9, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.4, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-02-03T01:15:07.647", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20220222-0005/" }, { "source": "cve@mitre.org", "tags": [ "Product", "Vendor Advisory" ], "url": "https://www.insyde.com/products" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20220222-0005/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Product", "Vendor Advisory" ], "url": "https://www.insyde.com/products" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-02-03 02:15
Modified
2024-11-21 06:09
Severity ?
Summary
An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.09.11, 5.1 before 05.17.11, 5.2 before 05.27.11, 5.3 before 05.36.11, 5.4 before 05.44.11, and 5.5 before 05.52.11 affecting FwBlockServiceSmm. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | Third Party Advisory | |
cve@mitre.org | https://security.netapp.com/advisory/ntap-20220222-0002/ | Third Party Advisory | |
cve@mitre.org | https://www.insyde.com/security-pledge | Vendor Advisory | |
cve@mitre.org | https://www.insyde.com/security-pledge/SA-2022022 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://security.netapp.com/advisory/ntap-20220222-0002/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.insyde.com/security-pledge | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.insyde.com/security-pledge/SA-2022022 | Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "95221F93-8BE6-47E3-BFB4-E7603C320F0D", "versionEndExcluding": "5.08.29", "versionStartIncluding": "5.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "D26CDAE4-0D04-4EB2-8A8C-CDEBDF8BA38C", "versionEndExcluding": "5.16.29", "versionStartIncluding": "5.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "E0546FD8-0648-46EB-893F-411F869077E5", "versionEndExcluding": "5.26.29", "versionStartIncluding": "5.2", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "89966555-5DD1-4C61-B3B2-7AF7AF7D24D9", "versionEndExcluding": "5.35.29", "versionStartIncluding": "5.3", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "324ADC7E-AECD-4B7D-8571-5399542C2BF6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*", "matchCriteriaId": "506DEE00-30D2-4E29-9645-757EB8778C0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "480C5657-5C05-40F5-B76A-E67119727ED8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F3C3E60-7C36-4F5D-B454-97C9D0FD9459", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc127e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2AEB5AD1-3973-4150-BEA2-C9DE0B98222F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*", "matchCriteriaId": "F63C0B17-60E2-4240-92FD-4B7C7D8F2C8B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc227g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C3F52F29-0ACF-4ECC-927A-0CB27399E5D9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc227g:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D1E85AC-1305-4C5E-AD8B-39B2654F6057", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc277g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F203C449-2B5C-47A1-BF3D-8DCFD29F0B18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc277g:-:*:*:*:*:*:*:*", "matchCriteriaId": "320F5752-86B3-4C08-89D0-02272753A6D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc327g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A37FB5EC-BB64-472C-81FC-8EEF238E3C12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc327g:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC7303D1-CC95-42C7-B843-C3B3B3336669", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc377g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "45013BCA-3897-4D58-81FA-D8CB9D19268C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc377g:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDD6F034-BC50-4223-AE5D-319F04C866A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F6422BF3-01B7-443B-BD2B-80E45D7C3F5F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*", "matchCriteriaId": "A40D0CDB-7BE6-491F-B730-3B4E10CA159A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "696F47E6-C1CA-4A58-A91F-4B3EA92954AF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDF9D4C3-1892-48FA-95B4-835B636A4005", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc627e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F712060C-ECDB-4BC7-B9B9-468B41DE615B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9AF082-8345-4BE1-B1FC-6E0316BB833B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc647e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D511C170-65E5-416D-B7CE-557A503F25AE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*", "matchCriteriaId": "E430C4C5-D887-47C6-B50F-66EEE9519151", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc677e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "577C19F5-82ED-46DF-91CC-A074DE99EBDD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc677e:-:*:*:*:*:*:*:*", "matchCriteriaId": "5F9FA42D-B2F0-456F-89B7-6A5789787FBA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc847e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CEF4592C-5DB3-45F4-B354-59701BBA0C08", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*", "matchCriteriaId": "1157418C-14C4-43C4-B63E-7E98D868A94F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "87F0538B-ED6E-40C7-9C2A-4C5DC3D2935E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "187C6D51-5B86-484D-AE0F-26D1C9465580", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.09.11, 5.1 before 05.17.11, 5.2 before 05.27.11, 5.3 before 05.36.11, 5.4 before 05.44.11, and 5.5 before 05.52.11 affecting FwBlockServiceSmm. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses." }, { "lang": "es", "value": "Se ha descubierto un problema en InsydeH2O versi\u00f3n 5.x, que afecta a FwBlockServiceSmm. Los servicios SMI de software que utilizan la funci\u00f3n Communicate() del EFI_SMM_COMMUNICATION_PROTOCOL no comprueban si la direcci\u00f3n del b\u00fafer es v\u00e1lida, lo que permite el uso de direcciones SMRAM, MMIO o del n\u00facleo del SO" } ], "id": "CVE-2021-33627", "lastModified": "2024-11-21T06:09:13.607", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.5, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-02-03T02:15:06.983", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20220222-0002/" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge/SA-2022022" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20220222-0002/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge/SA-2022022" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-02-03 02:15
Modified
2024-11-21 06:26
Severity ?
Summary
An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | Third Party Advisory | |
cve@mitre.org | https://security.netapp.com/advisory/ntap-20220222-0001/ | Third Party Advisory | |
cve@mitre.org | https://www.insyde.com/security-pledge | Vendor Advisory | |
cve@mitre.org | https://www.insyde.com/security-pledge/SA-2022023 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://security.netapp.com/advisory/ntap-20220222-0001/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.insyde.com/security-pledge | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.insyde.com/security-pledge/SA-2022023 | Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "A4803E0A-D93A-4863-B9F6-378C3D73F743", "versionEndExcluding": "5.16.42", "versionStartIncluding": "5.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "65D09B40-7B64-4890-AEA5-AE1EB5201CA1", "versionEndExcluding": "5.26.42", "versionStartIncluding": "5.2", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "E38FAADD-CEC5-421F-BBD7-1152B95B2A10", "versionEndExcluding": "5.35.42", "versionStartIncluding": "5.3", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "18B07541-9DA8-41A0-9D69-861C159AB6AA", "versionEndExcluding": "5.43.42", "versionStartIncluding": "5.4", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F835C39-35FE-45F8-9314-C7E072F3627D", "versionEndExcluding": "5.51.42", "versionStartIncluding": "5.5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "324ADC7E-AECD-4B7D-8571-5399542C2BF6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*", "matchCriteriaId": "506DEE00-30D2-4E29-9645-757EB8778C0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "480C5657-5C05-40F5-B76A-E67119727ED8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F3C3E60-7C36-4F5D-B454-97C9D0FD9459", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc127e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2AEB5AD1-3973-4150-BEA2-C9DE0B98222F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*", "matchCriteriaId": "F63C0B17-60E2-4240-92FD-4B7C7D8F2C8B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc227g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C3F52F29-0ACF-4ECC-927A-0CB27399E5D9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc227g:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D1E85AC-1305-4C5E-AD8B-39B2654F6057", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc277g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F203C449-2B5C-47A1-BF3D-8DCFD29F0B18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc277g:-:*:*:*:*:*:*:*", "matchCriteriaId": "320F5752-86B3-4C08-89D0-02272753A6D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc327g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A37FB5EC-BB64-472C-81FC-8EEF238E3C12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc327g:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC7303D1-CC95-42C7-B843-C3B3B3336669", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc377g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "45013BCA-3897-4D58-81FA-D8CB9D19268C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc377g:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDD6F034-BC50-4223-AE5D-319F04C866A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F6422BF3-01B7-443B-BD2B-80E45D7C3F5F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*", "matchCriteriaId": "A40D0CDB-7BE6-491F-B730-3B4E10CA159A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "696F47E6-C1CA-4A58-A91F-4B3EA92954AF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDF9D4C3-1892-48FA-95B4-835B636A4005", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc627e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F712060C-ECDB-4BC7-B9B9-468B41DE615B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9AF082-8345-4BE1-B1FC-6E0316BB833B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc647e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D511C170-65E5-416D-B7CE-557A503F25AE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*", "matchCriteriaId": "E430C4C5-D887-47C6-B50F-66EEE9519151", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc677e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "577C19F5-82ED-46DF-91CC-A074DE99EBDD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc677e:-:*:*:*:*:*:*:*", "matchCriteriaId": "5F9FA42D-B2F0-456F-89B7-6A5789787FBA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc847e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CEF4592C-5DB3-45F4-B354-59701BBA0C08", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*", "matchCriteriaId": "1157418C-14C4-43C4-B63E-7E98D868A94F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "87F0538B-ED6E-40C7-9C2A-4C5DC3D2935E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "187C6D51-5B86-484D-AE0F-26D1C9465580", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check." }, { "lang": "es", "value": "Se ha descubierto un problema en SdHostDriver en el kernel versi\u00f3n 5.0 hasta la versi\u00f3n 5.5 en InsydeH2O. Hay una llamada SMM que permite a un atacante acceder al modo de gesti\u00f3n del sistema y ejecutar c\u00f3digo arbitrario. Esto ocurre debido a una comparaci\u00f3n de rango num\u00e9rico sin una comprobaci\u00f3n m\u00ednima." } ], "id": "CVE-2021-41838", "lastModified": "2024-11-21T06:26:51.543", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.5, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-02-03T02:15:07.080", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20220222-0001/" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge/SA-2022023" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20220222-0001/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge/SA-2022023" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-10-01 03:15
Modified
2024-11-21 06:09
Severity ?
Summary
A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | Third Party Advisory | |
cve@mitre.org | https://security.netapp.com/advisory/ntap-20220216-0006/ | Third Party Advisory | |
cve@mitre.org | https://www.insyde.com/security-pledge | Vendor Advisory | |
cve@mitre.org | https://www.insyde.com/security-pledge/SA-2021001 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://security.netapp.com/advisory/ntap-20220216-0006/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.insyde.com/security-pledge | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.insyde.com/security-pledge/SA-2021001 | Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "7A8D4515-2E1D-4C69-B561-6F42B54FFD74", "versionEndExcluding": "5.34.44", "versionStartIncluding": "5.3", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "38BBAD45-A06D-41D6-A1CC-5AD560E9DCB8", "versionEndExcluding": "5.25.44", "versionStartIncluding": "5.2", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "816E66FC-0597-4442-9257-69B97D27D815", "versionEndExcluding": "5.16.25", "versionStartIncluding": "5.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "A889306B-C22C-4F29-BDBC-08B86252A584", "versionEndExcluding": "5.42.44", "versionStartIncluding": "5.4", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "C47A7464-4682-474D-B094-CB6F2BD3B6B4", "versionEndExcluding": "5.35.25", "versionStartIncluding": "5.3", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "0AECE476-8649-4928-9702-9E9737E1A764", "versionEndExcluding": "5.26.25", "versionStartIncluding": "5.2", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C8173E6-4FED-481D-BF5E-3CABDF13CA61", "versionEndExcluding": "5.43.25", "versionStartIncluding": "5.4", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ruggedcom_apr1808_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "E08DFAD2-130C-4B75-B7EF-602C4B3324F0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ruggedcom_apr1808:-:*:*:*:*:*:*:*", "matchCriteriaId": "BD56E8B2-232B-4E1C-BB3F-41B0C1E31D7B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "75AE72A3-05C6-4564-81CC-67865D03D106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*", "matchCriteriaId": "506DEE00-30D2-4E29-9645-757EB8778C0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "ECC5341D-9982-4F18-9C8D-2912DDB8EF9A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F3C3E60-7C36-4F5D-B454-97C9D0FD9459", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc127e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "846EE524-BC53-4DE5-81C5-6B5EB2DD8BEA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*", "matchCriteriaId": "F63C0B17-60E2-4240-92FD-4B7C7D8F2C8B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc227g_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "2ED11E5B-E60C-4359-B87C-E373DED77677", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc227g:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D1E85AC-1305-4C5E-AD8B-39B2654F6057", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc277g_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1865061F-CF02-410B-B01B-2088F7104867", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc277g:-:*:*:*:*:*:*:*", "matchCriteriaId": "320F5752-86B3-4C08-89D0-02272753A6D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc327g_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "68215EEF-243A-4B02-BEAB-C162A3564D60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc327g:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC7303D1-CC95-42C7-B843-C3B3B3336669", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc377g_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "62751FE8-48D7-4D7B-A7DD-4977DE539660", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc377g:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDD6F034-BC50-4223-AE5D-319F04C866A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc427e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "4EC3A82C-1380-4B21-BB17-3760A0B6A027", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*", "matchCriteriaId": "A40D0CDB-7BE6-491F-B730-3B4E10CA159A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2558478-44E0-4D42-A6DC-D4262D15A92A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDF9D4C3-1892-48FA-95B4-835B636A4005", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_pro_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "6AD30972-8CE2-46B4-A4B8-B209F6B616AC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc477e_pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "3FC5CE20-7D08-4496-A857-C3A4BD0AB1AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc627e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "EFFA7953-DC4C-489A-B5A4-B832FAF3C143", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9AF082-8345-4BE1-B1FC-6E0316BB833B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc647e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "0AC414E9-5DBD-4D60-B0EA-6FB48207B628", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*", "matchCriteriaId": "E430C4C5-D887-47C6-B50F-66EEE9519151", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc677e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "193BF353-5D85-4F2E-94D0-329ED823FF07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc677e:-:*:*:*:*:*:*:*", "matchCriteriaId": "5F9FA42D-B2F0-456F-89B7-6A5789787FBA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc847e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "D8CE311F-98F9-4E58-9E52-BAFAF87C0819", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*", "matchCriteriaId": "1157418C-14C4-43C4-B63E-7E98D868A94F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_itp1000_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "64538703-AE66-4D4A-B4A1-C88039B9543D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "187C6D51-5B86-484D-AE0F-26D1C9465580", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution." }, { "lang": "es", "value": "Existe una vulnerabilidad en la rama SMM (System Management Mode) que registra un manejador SWSMI que no comprueba o valida suficientemente el puntero del buffer asignado (valores QWORD para CommBuffer). Esto puede ser utilizado por un atacante para corromper los datos en la memoria SMRAM e incluso llevar a la ejecuci\u00f3n de c\u00f3digo arbitrario" } ], "id": "CVE-2021-33626", "lastModified": "2024-11-21T06:09:13.410", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-10-01T03:15:06.593", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20220216-0006/" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge/SA-2021001" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20220216-0006/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge/SA-2021001" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-829" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-02-03 02:15
Modified
2024-11-21 06:26
Severity ?
Summary
An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | Third Party Advisory | |
cve@mitre.org | https://security.netapp.com/advisory/ntap-20220222-0003/ | Third Party Advisory | |
cve@mitre.org | https://www.insyde.com/security-pledge | Vendor Advisory | |
cve@mitre.org | https://www.insyde.com/security-pledge/SA-2022024 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://security.netapp.com/advisory/ntap-20220222-0003/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.insyde.com/security-pledge | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.insyde.com/security-pledge/SA-2022024 | Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "A64DE17F-735B-490B-A4AD-8606684DDB5D", "versionEndExcluding": "5.08.41", "versionStartIncluding": "5.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "5EE9D6D0-77EF-41CE-ACB2-A43B0543F9C7", "versionEndExcluding": "5.16.41", "versionStartIncluding": "5.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "ADDAD8E2-7468-4D96-8A9F-8C2BB0E8EACB", "versionEndExcluding": "5.26.41", "versionStartIncluding": "5.2", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "7AF0CD01-CD57-41D5-9827-437F0683E13B", "versionEndExcluding": "5.35.41", "versionStartIncluding": "5.3", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "2DA61A73-A290-493E-A797-1A7E7AF0BDE5", "versionEndExcluding": "5.43.41", "versionStartIncluding": "5.4", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "0CB4ED22-F39A-45BD-B748-5C67D0BEEF53", "versionEndExcluding": "5.51.41", "versionStartIncluding": "5.5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "324ADC7E-AECD-4B7D-8571-5399542C2BF6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*", "matchCriteriaId": "506DEE00-30D2-4E29-9645-757EB8778C0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "480C5657-5C05-40F5-B76A-E67119727ED8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F3C3E60-7C36-4F5D-B454-97C9D0FD9459", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc127e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2AEB5AD1-3973-4150-BEA2-C9DE0B98222F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*", "matchCriteriaId": "F63C0B17-60E2-4240-92FD-4B7C7D8F2C8B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc227g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C3F52F29-0ACF-4ECC-927A-0CB27399E5D9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc227g:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D1E85AC-1305-4C5E-AD8B-39B2654F6057", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc277g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F203C449-2B5C-47A1-BF3D-8DCFD29F0B18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc277g:-:*:*:*:*:*:*:*", "matchCriteriaId": "320F5752-86B3-4C08-89D0-02272753A6D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc327g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A37FB5EC-BB64-472C-81FC-8EEF238E3C12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc327g:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC7303D1-CC95-42C7-B843-C3B3B3336669", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc377g_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "45013BCA-3897-4D58-81FA-D8CB9D19268C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc377g:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDD6F034-BC50-4223-AE5D-319F04C866A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F6422BF3-01B7-443B-BD2B-80E45D7C3F5F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*", "matchCriteriaId": "A40D0CDB-7BE6-491F-B730-3B4E10CA159A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "696F47E6-C1CA-4A58-A91F-4B3EA92954AF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDF9D4C3-1892-48FA-95B4-835B636A4005", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc627e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F712060C-ECDB-4BC7-B9B9-468B41DE615B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9AF082-8345-4BE1-B1FC-6E0316BB833B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc647e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D511C170-65E5-416D-B7CE-557A503F25AE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*", "matchCriteriaId": "E430C4C5-D887-47C6-B50F-66EEE9519151", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc677e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "577C19F5-82ED-46DF-91CC-A074DE99EBDD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc677e:-:*:*:*:*:*:*:*", "matchCriteriaId": "5F9FA42D-B2F0-456F-89B7-6A5789787FBA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc847e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CEF4592C-5DB3-45F4-B354-59701BBA0C08", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*", "matchCriteriaId": "1157418C-14C4-43C4-B63E-7E98D868A94F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "87F0538B-ED6E-40C7-9C2A-4C5DC3D2935E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "187C6D51-5B86-484D-AE0F-26D1C9465580", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM." }, { "lang": "es", "value": "Se descubri\u00f3 un problema en AhciBusDxe en el kernel versi\u00f3n 5.0 hasta la versi\u00f3n 5.5 en InsydeH2O. Debido a una desviaci\u00f3n de puntero no fiable que provoca la corrupci\u00f3n de la memoria de SMM, un atacante puede ser capaz de escribir datos fijos o predecibles en SMRAM. La explotaci\u00f3n de este problema podr\u00eda llevar a escalar privilegios a SMM" } ], "id": "CVE-2021-41837", "lastModified": "2024-11-21T06:26:51.320", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.5, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-02-03T02:15:07.033", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20220222-0003/" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge/SA-2022024" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20220222-0003/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge/SA-2022024" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-06-16 16:15
Modified
2024-11-21 05:21
Severity ?
Summary
In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5).
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | Third Party Advisory | |
cve@mitre.org | https://security.netapp.com/advisory/ntap-20220216-0005/ | Third Party Advisory | |
cve@mitre.org | https://www.insyde.com/security-pledge/SA-2021001 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://security.netapp.com/advisory/ntap-20220216-0005/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.insyde.com/security-pledge/SA-2021001 | Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "7A8D4515-2E1D-4C69-B561-6F42B54FFD74", "versionEndExcluding": "5.34.44", "versionStartIncluding": "5.3", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "38BBAD45-A06D-41D6-A1CC-5AD560E9DCB8", "versionEndExcluding": "5.25.44", "versionStartIncluding": "5.2", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "816E66FC-0597-4442-9257-69B97D27D815", "versionEndExcluding": "5.16.25", "versionStartIncluding": "5.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "A889306B-C22C-4F29-BDBC-08B86252A584", "versionEndExcluding": "5.42.44", "versionStartIncluding": "5.4", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "C47A7464-4682-474D-B094-CB6F2BD3B6B4", "versionEndExcluding": "5.35.25", "versionStartIncluding": "5.3", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "0AECE476-8649-4928-9702-9E9737E1A764", "versionEndExcluding": "5.26.25", "versionStartIncluding": "5.2", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C8173E6-4FED-481D-BF5E-3CABDF13CA61", "versionEndExcluding": "5.43.25", "versionStartIncluding": "5.4", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ruggedcom_apr1808_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "E08DFAD2-130C-4B75-B7EF-602C4B3324F0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ruggedcom_apr1808:-:*:*:*:*:*:*:*", "matchCriteriaId": "BD56E8B2-232B-4E1C-BB3F-41B0C1E31D7B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "75AE72A3-05C6-4564-81CC-67865D03D106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*", "matchCriteriaId": "506DEE00-30D2-4E29-9645-757EB8778C0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "ECC5341D-9982-4F18-9C8D-2912DDB8EF9A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F3C3E60-7C36-4F5D-B454-97C9D0FD9459", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc127e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "846EE524-BC53-4DE5-81C5-6B5EB2DD8BEA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*", "matchCriteriaId": "F63C0B17-60E2-4240-92FD-4B7C7D8F2C8B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc227g_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "2ED11E5B-E60C-4359-B87C-E373DED77677", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc227g:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D1E85AC-1305-4C5E-AD8B-39B2654F6057", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc277g_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1865061F-CF02-410B-B01B-2088F7104867", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc277g:-:*:*:*:*:*:*:*", "matchCriteriaId": "320F5752-86B3-4C08-89D0-02272753A6D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc327g_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "68215EEF-243A-4B02-BEAB-C162A3564D60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc327g:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC7303D1-CC95-42C7-B843-C3B3B3336669", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc377g_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "62751FE8-48D7-4D7B-A7DD-4977DE539660", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc377g:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDD6F034-BC50-4223-AE5D-319F04C866A8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc427e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "4EC3A82C-1380-4B21-BB17-3760A0B6A027", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*", "matchCriteriaId": "A40D0CDB-7BE6-491F-B730-3B4E10CA159A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2558478-44E0-4D42-A6DC-D4262D15A92A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*", "matchCriteriaId": "FDF9D4C3-1892-48FA-95B4-835B636A4005", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_pro_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "6AD30972-8CE2-46B4-A4B8-B209F6B616AC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc477e_pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "3FC5CE20-7D08-4496-A857-C3A4BD0AB1AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc627e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "EFFA7953-DC4C-489A-B5A4-B832FAF3C143", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9AF082-8345-4BE1-B1FC-6E0316BB833B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc647e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "0AC414E9-5DBD-4D60-B0EA-6FB48207B628", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*", "matchCriteriaId": "E430C4C5-D887-47C6-B50F-66EEE9519151", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc677e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "193BF353-5D85-4F2E-94D0-329ED823FF07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc677e:-:*:*:*:*:*:*:*", "matchCriteriaId": "5F9FA42D-B2F0-456F-89B7-6A5789787FBA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ipc847e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "D8CE311F-98F9-4E58-9E52-BAFAF87C0819", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*", "matchCriteriaId": "1157418C-14C4-43C4-B63E-7E98D868A94F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_itp1000_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "64538703-AE66-4D4A-B4A1-C88039B9543D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "187C6D51-5B86-484D-AE0F-26D1C9465580", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5)." }, { "lang": "es", "value": "En el kernel de Insyde InsydeH2O 5.x, algunos controladores SMM no validaban correctamente los par\u00e1metros CommBuffer y CommBufferSize, lo que permit\u00eda a los llamantes corromper el firmware o la memoria del sistema operativo. Las versiones corregidas para este problema en los controladores AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe y SdMcDeviceDxe son 05.16.25, 05.26.25, 05.35.25, 05.43.25 y 05.51.25 (para los n\u00facleos 5.1 a 5.5)" } ], "id": "CVE-2020-27339", "lastModified": "2024-11-21T05:21:01.897", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-06-16T16:15:07.897", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20220216-0005/" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge/SA-2021001" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20220216-0005/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge/SA-2021001" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }