cve-2021-33626
Vulnerability from cvelistv5
Published
2021-10-01 02:21
Modified
2024-08-03 23:58
Severity ?
Summary
A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution.
Impacted products
n/an/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:58:21.523Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.insyde.com/security-pledge"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.insyde.com/security-pledge/SA-2021001"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20220216-0006/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-22T19:07:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.insyde.com/security-pledge"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.insyde.com/security-pledge/SA-2021001"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220216-0006/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-33626",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.insyde.com/security-pledge",
              "refsource": "MISC",
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "name": "https://www.insyde.com/security-pledge/SA-2021001",
              "refsource": "MISC",
              "url": "https://www.insyde.com/security-pledge/SA-2021001"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20220216-0006/",
              "refsource": "CONFIRM",
              "url": "https://security.netapp.com/advisory/ntap-20220216-0006/"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ]
        },
        "source": {
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-33626",
    "datePublished": "2021-10-01T02:21:29",
    "dateReserved": "2021-05-28T00:00:00",
    "dateUpdated": "2024-08-03T23:58:21.523Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-33626\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2021-10-01T03:15:06.593\",\"lastModified\":\"2022-04-24T02:03:42.070\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad en la rama SMM (System Management Mode) que registra un manejador SWSMI que no comprueba o valida suficientemente el puntero del buffer asignado (valores QWORD para CommBuffer). Esto puede ser utilizado por un atacante para corromper los datos en la memoria SMRAM e incluso llevar a la ejecuci\u00f3n de c\u00f3digo arbitrario\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":4.6},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-829\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.3\",\"versionEndExcluding\":\"5.34.44\",\"matchCriteriaId\":\"7A8D4515-2E1D-4C69-B561-6F42B54FFD74\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.2\",\"versionEndExcluding\":\"5.25.44\",\"matchCriteriaId\":\"38BBAD45-A06D-41D6-A1CC-5AD560E9DCB8\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.1\",\"versionEndExcluding\":\"5.16.25\",\"matchCriteriaId\":\"816E66FC-0597-4442-9257-69B97D27D815\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.4\",\"versionEndExcluding\":\"5.42.44\",\"matchCriteriaId\":\"A889306B-C22C-4F29-BDBC-08B86252A584\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.3\",\"versionEndExcluding\":\"5.35.25\",\"matchCriteriaId\":\"C47A7464-4682-474D-B094-CB6F2BD3B6B4\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.2\",\"versionEndExcluding\":\"5.26.25\",\"matchCriteriaId\":\"0AECE476-8649-4928-9702-9E9737E1A764\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.4\",\"versionEndExcluding\":\"5.43.25\",\"matchCriteriaId\":\"5C8173E6-4FED-481D-BF5E-3CABDF13CA61\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:ruggedcom_apr1808:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BD56E8B2-232B-4E1C-BB3F-41B0C1E31D7B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:ruggedcom_apr1808_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E08DFAD2-130C-4B75-B7EF-602C4B3324F0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"506DEE00-30D2-4E29-9645-757EB8778C0F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"75AE72A3-05C6-4564-81CC-67865D03D106\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8F3C3E60-7C36-4F5D-B454-97C9D0FD9459\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"ECC5341D-9982-4F18-9C8D-2912DDB8EF9A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F63C0B17-60E2-4240-92FD-4B7C7D8F2C8B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc127e_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"846EE524-BC53-4DE5-81C5-6B5EB2DD8BEA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc227g:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0D1E85AC-1305-4C5E-AD8B-39B2654F6057\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc227g_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2ED11E5B-E60C-4359-B87C-E373DED77677\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc277g:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"320F5752-86B3-4C08-89D0-02272753A6D0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc277g_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1865061F-CF02-410B-B01B-2088F7104867\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc327g_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"68215EEF-243A-4B02-BEAB-C162A3564D60\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc327g:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EC7303D1-CC95-42C7-B843-C3B3B3336669\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc377g_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"62751FE8-48D7-4D7B-A7DD-4977DE539660\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc377g:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FDD6F034-BC50-4223-AE5D-319F04C866A8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc427e_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4EC3A82C-1380-4B21-BB17-3760A0B6A027\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A40D0CDB-7BE6-491F-B730-3B4E10CA159A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc477e_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B2558478-44E0-4D42-A6DC-D4262D15A92A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FDF9D4C3-1892-48FA-95B4-835B636A4005\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc477e_pro_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6AD30972-8CE2-46B4-A4B8-B209F6B616AC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc477e_pro:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3FC5CE20-7D08-4496-A857-C3A4BD0AB1AC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc627e_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EFFA7953-DC4C-489A-B5A4-B832FAF3C143\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9D9AF082-8345-4BE1-B1FC-6E0316BB833B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc647e_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0AC414E9-5DBD-4D60-B0EA-6FB48207B628\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E430C4C5-D887-47C6-B50F-66EEE9519151\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc677e_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"193BF353-5D85-4F2E-94D0-329ED823FF07\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc677e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5F9FA42D-B2F0-456F-89B7-6A5789787FBA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc847e_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D8CE311F-98F9-4E58-9E52-BAFAF87C0819\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1157418C-14C4-43C4-B63E-7E98D868A94F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_itp1000_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"64538703-AE66-4D4A-B4A1-C88039B9543D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"187C6D51-5B86-484D-AE0F-26D1C9465580\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20220216-0006/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.insyde.com/security-pledge\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.insyde.com/security-pledge/SA-2021001\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.