All the vulnerabilites related to siemens - simatic_it_production_suite
Vulnerability from fkie_nvd
Published
2018-12-13 16:29
Modified
2024-11-21 03:48
Severity ?
Summary
A vulnerability has been identified in SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (Versions V7.1 < V7.1 Upd3), SIMATIC IT UA Discrete Manufacturing (Versions < V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.4). An attacker with network access to the installation could bypass the application-level authentication. In order to exploit the vulnerability, an attacker must obtain network access to an affected installation and must obtain a valid username to the system. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | http://www.securityfocus.com/bid/105924 | Third Party Advisory, VDB Entry | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-886615.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/105924 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-886615.pdf | Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_it_line_monitoring_system:*:*:*:*:*:*:*:*", "matchCriteriaId": "6D5EA164-9BEF-4484-BE38-44FB88621DAF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_it_production_suite:v7.1:*:*:*:*:*:*:*", "matchCriteriaId": "1DA44902-E2E1-4905-B079-4175B77BA6C1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_it_ua_discrete_manufacturing:*:*:*:*:*:*:*:*", "matchCriteriaId": "B80F843B-EE5E-4E6E-A55B-7645851E3C94", "versionEndIncluding": "v1.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_it_ua_discrete_manufacturing:v1.3:*:*:*:*:*:*:*", "matchCriteriaId": "ADB0EE1B-B674-4F10-805C-E893F546F1F5", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_it_ua_discrete_manufacturing:v2.3:*:*:*:*:*:*:*", "matchCriteriaId": "4FA4E503-A04B-43F9-B8F0-2CA8F4332A5E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_it_ua_discrete_manufacturing:v2.4:*:*:*:*:*:*:*", "matchCriteriaId": "3239A643-480F-4CDC-9CEF-5F1FB0FDD5D5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (Versions V7.1 \u003c V7.1 Upd3), SIMATIC IT UA Discrete Manufacturing (Versions \u003c V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.4). An attacker with network access to the installation could bypass the application-level authentication. In order to exploit the vulnerability, an attacker must obtain network access to an affected installation and must obtain a valid username to the system. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC IT LMS (todas las versiones), SIMATIC IT Production Suite (versiones V7.1 anteriores a V7.1 Upd3), SIMATIC IT UA Discrete Manufacturing (versiones anteriores a V1.2), SIMATIC IT UA Discrete Manufacturing (versiones V1.2), SIMATIC IT UA Discrete Manufacturing (versiones V1.3), SIMATIC IT UA Discrete Manufacturing (versiones V2.3) y SIMATIC IT UA Discrete Manufacturing (versiones V2.4). Un atacante con acceso de red a la instalaci\u00f3n podr\u00eda omitir la autenticaci\u00f3n a nivel de aplicaci\u00f3n. Para explotar esta vulnerabilidad, un atacante debe obtener acceso de red a una instalaci\u00f3n afectada y debe obtener un usuario v\u00e1lido en el sistema. Su explotaci\u00f3n con \u00e9xito no requiere privilegios de usuario ni interacci\u00f3n. La vulnerabilidad podr\u00eda permitir que un atacante comprometa la confidencialidad, integridad y disponibilidad del sistema. En el momento de la publicaci\u00f3n del aviso, no se conoce ninguna explotaci\u00f3n p\u00fablica de la vulnerabilidad." } ], "id": "CVE-2018-13804", "lastModified": "2024-11-21T03:48:04.973", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-12-13T16:29:00.210", "references": [ { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/105924" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-886615.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/105924" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-886615.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2016-11-15 19:30
Modified
2024-11-21 02:57
Severity ?
Summary
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path ("C:\Program Files\*" or the localized equivalent).
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html | Third Party Advisory | |
cve@mitre.org | http://www.securityfocus.com/bid/94158 | Third Party Advisory, VDB Entry | |
cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf | ||
cve@mitre.org | https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/94158 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf | ||
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:primary_setup_tool:-:*:*:*:*:*:*:*", "matchCriteriaId": "8046A64D-4C80-4199-B1A7-F77D02428ACD", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:security_configuration_tool:-:*:*:*:*:*:*:*", "matchCriteriaId": "C33765E4-619E-4566-BF96-4A7C8776A0CB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_it_production_suite:-:*:*:*:*:*:*:*", "matchCriteriaId": "DBCAF7A5-CA65-4D88-8473-67947726CA2D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_net_pc_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "87DF85DE-B86C-459A-A9A9-096AF7A661E6", "versionEndIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "4DFBFF6B-DBC8-451D-A235-4C7E1F0883D5", "versionEndIncluding": "7.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*", "matchCriteriaId": "E8B894F4-9635-4436-BC0A-E43280426017", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.1:*:*:*:*:*:*:*", "matchCriteriaId": "172A6A81-C32E-4ACC-AB8C-2014BF3A6901", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.2:*:*:*:*:*:*:*", "matchCriteriaId": "8C6E8BBF-C5FF-4F13-AC70-2FF41CF3CC8E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:sp4:*:*:*:*:*:*", "matchCriteriaId": "C60C6533-1875-4E5B-A367-F6C1C1345CCF", "versionEndIncluding": "5.5", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):*:*:*:*:*:*:*:*", "matchCriteriaId": "A4053231-D271-4A23-B0A0-374F6EAE2EF8", "versionEndIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_winac_rtx_2010:-:*:*:*:*:*:*:*", "matchCriteriaId": "AD93D757-C2DE-444C-9FF4-A7A700EFF7F0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_winac_rtx_f_2010:-:*:*:*:*:*:*:*", "matchCriteriaId": "042D7AB5-8DB7-478E-8CB8-31942D360B34", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:sp2:*:*:*:*:*:*", "matchCriteriaId": "B9D3442E-E362-49BA-8699-629A611A6E2E", "versionEndIncluding": "7.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp3:*:*:*:*:*:*", "matchCriteriaId": "0D0BB2E6-1444-499A-943E-8D19C402F1BD", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:*:*:*:*:*:*:*", "matchCriteriaId": "4C4BFBED-E818-453C-B787-22D67B4A5A29", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:*", "matchCriteriaId": "8D6229A2-9B8E-4F76-8425-589D2CE58B16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*", "matchCriteriaId": "F64B795A-7E66-49AE-BE40-E8EEAC12D280", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:advanced:*:*:*", "matchCriteriaId": "882F53D9-7AAA-4647-B071-A45CA2618AA1", "versionEndIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:basic:*:*:*", "matchCriteriaId": "F4524CA7-833B-4577-A5E5-DB47704F49AF", "versionEndIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:comfort:*:*:*", "matchCriteriaId": "58782A2B-6A27-475A-9FAB-0272DED5DB40", "versionEndIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):-:*:*:*:professional:*:*:*", "matchCriteriaId": "D9BA6A34-593E-466A-B11B-1E2DC890ECF6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:professional:*:*:*", "matchCriteriaId": "E6BFBAED-EE2B-4DE4-A76C-824DD15F4608", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simit:9.0:*:*:*:*:*:*:*", "matchCriteriaId": "939DE56D-D8D7-42B8-BC0C-D6727E99AFA3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_remote_connect:-:*:*:*:*:*:*:*", "matchCriteriaId": "9646F056-080A-4F45-AABD-4D6E8AF05148", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:*:sp2:*:*:*:*:*:*", "matchCriteriaId": "3F8B6E52-C339-41B9-A2C1-A6D161251648", "versionEndIncluding": "13.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:softnet_security_client:*:*:*:*:*:*:*:*", "matchCriteriaId": "18BFF869-4E4E-4410-91F7-56A7E959C0FE", "versionEndIncluding": "5.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:telecontrol_basic:*:sp2:*:*:*:*:*:*", "matchCriteriaId": "A9386816-33A5-4DA7-931B-841AAE40E3BE", "versionEndIncluding": "3.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent)." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Primary Setup Tool (PST) (todas las versiones anteriores a V4.2 HF1), SIMATIC IT Production Suite (todas las versiones anteriores a V7.0 SP1 HFX 2), SIMATIC NET PC-Software (Todas las versiones anteriores a V14), SIMATIC PCS 7 versi\u00f3n V7.1 (Todas las versiones), SIMATIC PCS 7 versi\u00f3n V8.0 (Todas las versiones), SIMATIC PCS 7 versi\u00f3n V8.1 (Todas las versiones),SIMATIC PCS 7 versi\u00f3n V8.2 (Todas las versiones anteriores a V8.2 SP1), SIMATIC STEP 7 (TIA Portal) versi\u00f3n V13 (Todas las versiones anteriores a V13 SP2), SIMATIC STEP 7 versiones V5.X (Todas las versiones anteriores a V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (Todas las versiones anteriores a V14), SIMATIC WinCC (TIA Portal) Professional versi\u00f3n V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC (TIA Portal) Professional versi\u00f3n V14 (Todas las versiones anteriores a V14 SP1), SIMATIC WinCC Runtime Professional versi\u00f3n V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC Runtime Professional versi\u00f3n V14 (Todas las versiones anteriores a V14 SP1), SIMATIC WinCC versi\u00f3n V7.0 SP2 y anteriores (Todas las versiones anteriores a V7.0 SP2 Upd 12), SIMATIC WinCC versi\u00f3n V7.0 SP3 (Todas las versiones anteriores a V7.0 SP3 Upd 8), SIMATIC WinCC versi\u00f3n V7.2 (Todas las versiones anteriores a V7.2 Upd 14), SIMATIC WinCC versi\u00f3n V7.3 (Todas las versiones anteriores a V7.3 Upd 11), SIMATIC WinCC versi\u00f3n V7.4 (Todas las versiones anteriores a V7.4 SP1), SIMIT versi\u00f3n V9.0 (Todas las versiones anteriores a V9.0 SP1), SINEMA Remote Connect Client (Todas las versiones anteriores a V1.0 SP3), SINEMA Server (Todas las versiones anteriores a V13 SP2), SOFTNET Security Client versi\u00f3n V5.0 (Todas las versiones), Security Configuration Tool (SCT) (Todas las versiones anteriores a V4.3 HF1), TeleControl Server Basic (Todas las versiones anteriores a V3.0 SP2), WinAC RTX 2010 SP2 (Todas las versiones), WinAC RTX F 2010 SP2 (Todas las versiones). Las rutas (path) de servicio sin comillas podr\u00edan permitir que los usuarios locales del sistema operativo Microsoft Windows aumenten sus privilegios si los productos afectados no est\u00e1n instalados en su ruta (path) de acceso predeterminada (\"C:\\Program Files\\*\" o el equivalente localizado)." } ], "id": "CVE-2016-7165", "lastModified": "2024-11-21T02:57:37.740", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 6.9, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.4, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.5, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2016-11-15T19:30:02.797", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/94158" }, { "source": "cve@mitre.org", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/94158" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-254" }, { "lang": "en", "value": "CWE-284" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-14 14:15
Modified
2024-11-21 05:37
Severity ?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:*", "matchCriteriaId": "F33BF89C-F36E-4C8F-ABB9-579E2022DDA6", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DCE5E06-B75F-4D21-96CC-70DD373B1811", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:*", "matchCriteriaId": "C4DD5C57-5877-495C-A01E-747E5DCED9F7", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:*", "matchCriteriaId": "E927136F-3870-47AD-BE56-C83FBD7BB7E9", "versionEndExcluding": "3.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:*", "matchCriteriaId": "9DB2F53B-817C-41F3-9B52-85DE702ACCE5", "versionEndExcluding": "11.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_rd\\\u0026l:8.0:*:*:*:*:*:*:*", "matchCriteriaId": "EE037602-C9E8-45D5-9A44-3B73052F478E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_it_lms:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F8E56A4-77DB-4938-93E5-2CA22222FD6A", "versionEndExcluding": "2.6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_it_production_suite:*:*:*:*:*:*:*:*", "matchCriteriaId": "218D5A8B-FC2D-440C-B853-35E93A025A6E", "versionEndExcluding": "8.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:*", "matchCriteriaId": "DE74021F-CE57-42CC-8093-E1B0352410FA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "32A732D2-5E9E-4C8B-93C1-2E0BEBA7B327", "versionEndExcluding": "3.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:3.0:-:*:*:*:*:*:*", "matchCriteriaId": "B275D75A-1869-4660-A1FF-837A9C0F874B", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "6729BE2B-6729-4041-BC8C-2AD039467B9A", "versionEndExcluding": "15.1", "versionStartIncluding": "15", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "C470C8EF-BBF5-4940-944E-2460BA6D8A27", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*", "matchCriteriaId": "66CB66B9-176E-4FA3-BC67-E7C5972A307C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:update1:*:*:*:*:*:*", "matchCriteriaId": "EF2D6947-576B-4CA7-B4E4-F0B428FA5ABB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*", "matchCriteriaId": "098E9BE1-D698-4DE5-96C1-DF0B3806C935", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simocode_es:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "8DA3C5DB-8D27-4CDD-AA93-ABE1EE021CAF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simocode_es:16:-:*:*:*:*:*:*", "matchCriteriaId": "8829878A-34E1-44D5-B4BC-12CF67CB58C2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*", "matchCriteriaId": "D1E0C95F-8201-4F04-99A6-62B9684BF35F", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:soft_starter_es:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "7039A3C6-5DE3-4980-8A2F-A05928561673", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Opcenter Execution Discrete (Todas las versiones anteriores a V3.2), Opcenter Execution Foundation (Todas las versiones anteriores a V3.2), Opcenter Execution Process (Todas las versiones anteriores a V3.2), Opcenter Intelligence (Todas las versiones anteriores a V3.3), Opcenter Quality (Todas las versiones anteriores a V11.3), Opcenter RD\u0026amp;L (V8.0), SIMATIC IT LMS (Todas las versiones anteriores a V2.6), SIMATIC IT Production Suite (Todas las versiones anteriores a V8. 0), SIMATIC Notifier Server for Windows (Todas las versiones), SIMATIC PCS neo (Todas las versiones anteriores a V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (Todas las versiones anteriores a V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (Todas las versiones anteriores a V16 Update 2), SIMOCODE ES V15. 1 (Todas las versiones anteriores a V15.1 Update 4), SIMOCODE ES V16 (Todas las versiones anteriores a V16 Update 1), Soft Starter ES V15.1 (Todas las versiones anteriores a V15.1 Update 3), Soft Starter ES V16 (Todas las versiones anteriores a V16 Update 1). El env\u00edo de m\u00faltiples paquetes especialmente dise\u00f1ados al servicio afectado podr\u00eda causar una denegaci\u00f3n de servicio remota parcial, que har\u00eda que el servicio se reiniciara. En algunos casos la vulnerabilidad podr\u00eda filtrar informaci\u00f3n aleatoria del servicio remoto" } ], "id": "CVE-2020-7587", "lastModified": "2024-11-21T05:37:25.533", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.4, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 4.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:18.930", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-14 14:15
Modified
2024-11-21 05:37
Severity ?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:*", "matchCriteriaId": "F33BF89C-F36E-4C8F-ABB9-579E2022DDA6", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DCE5E06-B75F-4D21-96CC-70DD373B1811", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:*", "matchCriteriaId": "C4DD5C57-5877-495C-A01E-747E5DCED9F7", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:*", "matchCriteriaId": "FA9BAFAE-C26A-4435-80C1-508F0A3EF768", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:*", "matchCriteriaId": "9DB2F53B-817C-41F3-9B52-85DE702ACCE5", "versionEndExcluding": "11.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_rd\\\u0026l:8.0:*:*:*:*:*:*:*", "matchCriteriaId": "EE037602-C9E8-45D5-9A44-3B73052F478E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_it_lms:*:*:*:*:*:*:*:*", "matchCriteriaId": "524AE90C-821A-4864-B3B2-33C083B536CB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_it_production_suite:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6324685-60ED-44CC-BAEA-3BEEBE681AC5", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:*", "matchCriteriaId": "DE74021F-CE57-42CC-8093-E1B0352410FA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "D61D4B81-7F51-49BE-83DD-D2C28D23B0EA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "2190AEE1-7EEA-48A9-B6C7-FF4B3A26008E", "versionEndIncluding": "15.1", "versionStartIncluding": "15", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*", "matchCriteriaId": "66CB66B9-176E-4FA3-BC67-E7C5972A307C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:update_1:*:*:*:*:*:*", "matchCriteriaId": "4E011D6F-CC5F-4278-80AB-D568730AA041", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE934FDC-666F-4D9D-9C03-2896875F0A0D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*", "matchCriteriaId": "FA57190F-97BA-4D1D-BC73-F37162B775F9", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Opcenter Execution Discrete (Todas las versiones anteriores a V3.2), Opcenter Execution Foundation (Todas las versiones anteriores a V3.2), Opcenter Execution Process (Todas las versiones anteriores a V3.2), Opcenter Intelligence (Todas las versiones anteriores a V3.3), Opcenter Quality (Todas las versiones anteriores a V11.3), Opcenter RD\u0026amp;L (V8.0), SIMATIC IT LMS (Todas las versiones anteriores a V2.6), SIMATIC IT Production Suite (Todas las versiones anteriores a V8. 0), SIMATIC Notifier Server for Windows (Todas las versiones), SIMATIC PCS neo (Todas las versiones anteriores a V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (Todas las versiones anteriores a V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (Todas las versiones anteriores a V16 Update 2), SIMOCODE ES V15. 1 (Todas las versiones anteriores a V15.1 Update 4), SIMOCODE ES V16 (Todas las versiones anteriores a V16 Update 1), Soft Starter ES V15.1 (Todas las versiones anteriores a V15.1 Update 3), Soft Starter ES V16 (Todas las versiones anteriores a V16 Update 1). El env\u00edo de un paquete especialmente dise\u00f1ado al servicio afectado podr\u00eda causar una denegaci\u00f3n de servicio remota parcial, que har\u00eda que el servicio se reiniciara" } ], "id": "CVE-2020-7588", "lastModified": "2024-11-21T05:37:25.660", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:18.993", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
cve-2016-7165
Vulnerability from cvelistv5
Published
2016-11-15 19:00
Modified
2024-08-06 01:50
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path ("C:\Program Files\*" or the localized equivalent).
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02 | x_refsource_MISC | |
http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html | x_refsource_MISC | |
http://www.securityfocus.com/bid/94158 | vdb-entry, x_refsource_BID | |
https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T01:50:47.526Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html" }, { "name": "94158", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/94158" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2016-11-07T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent)." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-06-14T20:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02" }, { "tags": [ "x_refsource_MISC" ], "url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html" }, { "name": "94158", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/94158" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2016-7165", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02" }, { "name": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html", "refsource": "MISC", "url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html" }, { "name": "94158", "refsource": "BID", "url": "http://www.securityfocus.com/bid/94158" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2016-7165", "datePublished": "2016-11-15T19:00:00", "dateReserved": "2016-09-08T00:00:00", "dateUpdated": "2024-08-06T01:50:47.526Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-13804
Vulnerability from cvelistv5
Published
2018-12-13 16:00
Modified
2024-08-05 09:14
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (Versions V7.1 < V7.1 Upd3), SIMATIC IT UA Discrete Manufacturing (Versions < V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.4). An attacker with network access to the installation could bypass the application-level authentication. In order to exploit the vulnerability, an attacker must obtain network access to an affected installation and must obtain a valid username to the system. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-886615.pdf | x_refsource_CONFIRM | |
http://www.securityfocus.com/bid/105924 | vdb-entry, x_refsource_BID |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens AG | SIMATIC IT LMS, SIMATIC IT Production Suite, SIMATIC IT UA Discrete Manufacturing, SIMATIC IT UA Discrete Manufacturing, SIMATIC IT UA Discrete Manufacturing, SIMATIC IT UA Discrete Manufacturing, SIMATIC IT UA Discrete Manufacturing |
Version: SIMATIC IT LMS : All versions Version: SIMATIC IT Production Suite : Versions V7.1 < V7.1 Upd3 Version: SIMATIC IT UA Discrete Manufacturing : Versions < V1.2 Version: SIMATIC IT UA Discrete Manufacturing : Versions V1.2 Version: SIMATIC IT UA Discrete Manufacturing : Versions V1.3 Version: SIMATIC IT UA Discrete Manufacturing : Versions V2.3 Version: SIMATIC IT UA Discrete Manufacturing : Versions V2.4 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T09:14:47.168Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-886615.pdf" }, { "name": "105924", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/105924" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC IT LMS, SIMATIC IT Production Suite, SIMATIC IT UA Discrete Manufacturing, SIMATIC IT UA Discrete Manufacturing, SIMATIC IT UA Discrete Manufacturing, SIMATIC IT UA Discrete Manufacturing, SIMATIC IT UA Discrete Manufacturing", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "SIMATIC IT LMS : All versions" }, { "status": "affected", "version": "SIMATIC IT Production Suite : Versions V7.1 \u003c V7.1 Upd3" }, { "status": "affected", "version": "SIMATIC IT UA Discrete Manufacturing : Versions \u003c V1.2" }, { "status": "affected", "version": "SIMATIC IT UA Discrete Manufacturing : Versions V1.2" }, { "status": "affected", "version": "SIMATIC IT UA Discrete Manufacturing : Versions V1.3" }, { "status": "affected", "version": "SIMATIC IT UA Discrete Manufacturing : Versions V2.3" }, { "status": "affected", "version": "SIMATIC IT UA Discrete Manufacturing : Versions V2.4" } ] } ], "datePublic": "2018-12-13T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (Versions V7.1 \u003c V7.1 Upd3), SIMATIC IT UA Discrete Manufacturing (Versions \u003c V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.4). An attacker with network access to the installation could bypass the application-level authentication. In order to exploit the vulnerability, an attacker must obtain network access to an affected installation and must obtain a valid username to the system. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-287", "description": "CWE-287: Improper Authentication", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-12-14T10:57:02", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-886615.pdf" }, { "name": "105924", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/105924" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2018-13804", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC IT LMS, SIMATIC IT Production Suite, SIMATIC IT UA Discrete Manufacturing, SIMATIC IT UA Discrete Manufacturing, SIMATIC IT UA Discrete Manufacturing, SIMATIC IT UA Discrete Manufacturing, SIMATIC IT UA Discrete Manufacturing", "version": { "version_data": [ { "version_value": "SIMATIC IT LMS : All versions" }, { "version_value": "SIMATIC IT Production Suite : Versions V7.1 \u003c V7.1 Upd3" }, { "version_value": "SIMATIC IT UA Discrete Manufacturing : Versions \u003c V1.2" }, { "version_value": "SIMATIC IT UA Discrete Manufacturing : Versions V1.2" }, { "version_value": "SIMATIC IT UA Discrete Manufacturing : Versions V1.3" }, { "version_value": "SIMATIC IT UA Discrete Manufacturing : Versions V2.3" }, { "version_value": "SIMATIC IT UA Discrete Manufacturing : Versions V2.4" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (Versions V7.1 \u003c V7.1 Upd3), SIMATIC IT UA Discrete Manufacturing (Versions \u003c V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.4). An attacker with network access to the installation could bypass the application-level authentication. In order to exploit the vulnerability, an attacker must obtain network access to an affected installation and must obtain a valid username to the system. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-287: Improper Authentication" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-886615.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-886615.pdf" }, { "name": "105924", "refsource": "BID", "url": "http://www.securityfocus.com/bid/105924" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2018-13804", "datePublished": "2018-12-13T16:00:00", "dateReserved": "2018-07-10T00:00:00", "dateUpdated": "2024-08-05T09:14:47.168Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-7588
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 09:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Opcenter Execution Discrete |
Version: All versions < V3.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:33:19.850Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Opcenter Execution Discrete", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Execution Process", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Intelligence", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V11.3" } ] }, { "product": "Opcenter RD\u0026L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V8.0" } ] }, { "product": "SIMATIC IT LMS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.6" } ] }, { "product": "SIMATIC IT Production Suite", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.0" } ] }, { "product": "SIMATIC Notifier Server for Windows", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0 SP1" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMOCODE ES V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 4" } ] }, { "product": "SIMOCODE ES V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] }, { "product": "Soft Starter ES V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 3" } ] }, { "product": "Soft Starter ES V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20: Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-10T11:16:56", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-7588", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Opcenter Execution Discrete", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Execution Foundation", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Execution Process", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Intelligence", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "Opcenter Quality", "version": { "version_data": [ { "version_value": "All versions \u003c V11.3" } ] } }, { "product_name": "Opcenter RD\u0026L", "version": { "version_data": [ { "version_value": "V8.0" } ] } }, { "product_name": "SIMATIC IT LMS", "version": { "version_data": [ { "version_value": "All versions \u003c V2.6" } ] } }, { "product_name": "SIMATIC IT Production Suite", "version": { "version_data": [ { "version_value": "All versions \u003c V8.0" } ] } }, { "product_name": "SIMATIC Notifier Server for Windows", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC PCS neo", "version": { "version_data": [ { "version_value": "All versions \u003c V3.0 SP1" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal) V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 5" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal) V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 2" } ] } }, { "product_name": "SIMOCODE ES V15.1", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 4" } ] } }, { "product_name": "SIMOCODE ES V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 1" } ] } }, { "product_name": "Soft Starter ES V15.1", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 3" } ] } }, { "product_name": "Soft Starter ES V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20: Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-7588", "datePublished": "2020-07-14T13:18:05", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:33:19.850Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-7587
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 09:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Opcenter Execution Discrete |
Version: All versions < V3.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:33:19.877Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Opcenter Execution Discrete", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Execution Process", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Intelligence", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V11.3" } ] }, { "product": "Opcenter RD\u0026L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V8.0" } ] }, { "product": "SIMATIC IT LMS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.6" } ] }, { "product": "SIMATIC IT Production Suite", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.0" } ] }, { "product": "SIMATIC Notifier Server for Windows", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0 SP1" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMOCODE ES V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 4" } ] }, { "product": "SIMOCODE ES V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] }, { "product": "Soft Starter ES V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 3" } ] }, { "product": "Soft Starter ES V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-10T11:16:51", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-7587", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Opcenter Execution Discrete", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Execution Foundation", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Execution Process", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Intelligence", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "Opcenter Quality", "version": { "version_data": [ { "version_value": "All versions \u003c V11.3" } ] } }, { "product_name": "Opcenter RD\u0026L", "version": { "version_data": [ { "version_value": "V8.0" } ] } }, { "product_name": "SIMATIC IT LMS", "version": { "version_data": [ { "version_value": "All versions \u003c V2.6" } ] } }, { "product_name": "SIMATIC IT Production Suite", "version": { "version_data": [ { "version_value": "All versions \u003c V8.0" } ] } }, { "product_name": "SIMATIC Notifier Server for Windows", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC PCS neo", "version": { "version_data": [ { "version_value": "All versions \u003c V3.0 SP1" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal) V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 5" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal) V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 2" } ] } }, { "product_name": "SIMOCODE ES V15.1", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 4" } ] } }, { "product_name": "SIMOCODE ES V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 1" } ] } }, { "product_name": "Soft Starter ES V15.1", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 3" } ] } }, { "product_name": "Soft Starter ES V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400: Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-7587", "datePublished": "2020-07-14T13:18:05", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:33:19.877Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }