A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path ("C:\Program Files\*" or the localized equivalent).
Impacted products
n/an/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T01:50:47.526Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
          },
          {
            "name": "94158",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/94158"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2016-11-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-06-14T20:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
        },
        {
          "name": "94158",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/94158"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2016-7165",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
            },
            {
              "name": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html",
              "refsource": "MISC",
              "url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
            },
            {
              "name": "94158",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/94158"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2016-7165",
    "datePublished": "2016-11-15T19:00:00",
    "dateReserved": "2016-09-08T00:00:00",
    "dateUpdated": "2024-08-06T01:50:47.526Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2016-7165\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2016-11-15T19:30:02.797\",\"lastModified\":\"2018-06-15T01:29:00.310\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\\\"C:\\\\Program Files\\\\*\\\" or the localized equivalent).\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Primary Setup Tool (PST) (todas las versiones anteriores a V4.2 HF1), SIMATIC IT Production Suite (todas las versiones anteriores a V7.0 SP1 HFX 2), SIMATIC NET PC-Software (Todas las versiones anteriores a V14), SIMATIC PCS 7 versi\u00f3n V7.1 (Todas las versiones), SIMATIC PCS 7 versi\u00f3n V8.0 (Todas las versiones), SIMATIC PCS 7 versi\u00f3n V8.1 (Todas las versiones),SIMATIC PCS 7 versi\u00f3n V8.2 (Todas las versiones anteriores a V8.2 SP1), SIMATIC STEP 7 (TIA Portal) versi\u00f3n V13 (Todas las versiones anteriores a V13 SP2), SIMATIC STEP 7 versiones V5.X (Todas las versiones anteriores a V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (Todas las versiones anteriores a V14), SIMATIC WinCC (TIA Portal) Professional versi\u00f3n V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC (TIA Portal) Professional versi\u00f3n V14 (Todas las versiones anteriores a V14 SP1), SIMATIC WinCC Runtime Professional versi\u00f3n V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC Runtime Professional versi\u00f3n V14 (Todas las versiones anteriores a V14 SP1), SIMATIC WinCC versi\u00f3n V7.0 SP2 y anteriores (Todas las versiones anteriores a V7.0 SP2 Upd 12), SIMATIC WinCC versi\u00f3n V7.0 SP3 (Todas las versiones anteriores a V7.0 SP3 Upd 8), SIMATIC WinCC versi\u00f3n V7.2 (Todas las versiones anteriores a V7.2 Upd 14), SIMATIC WinCC versi\u00f3n V7.3 (Todas las versiones anteriores a V7.3 Upd 11), SIMATIC WinCC versi\u00f3n V7.4 (Todas las versiones anteriores a V7.4 SP1), SIMIT versi\u00f3n V9.0 (Todas las versiones anteriores a V9.0 SP1), SINEMA Remote Connect Client (Todas las versiones anteriores a V1.0 SP3), SINEMA Server (Todas las versiones anteriores a V13 SP2), SOFTNET Security Client versi\u00f3n V5.0 (Todas las versiones), Security Configuration Tool (SCT) (Todas las versiones anteriores a V4.3 HF1), TeleControl Server Basic (Todas las versiones anteriores a V3.0 SP2), WinAC RTX 2010 SP2 (Todas las versiones), WinAC RTX F 2010 SP2 (Todas las versiones). Las rutas (path) de servicio sin comillas podr\u00edan permitir que los usuarios locales del sistema operativo Microsoft Windows aumenten sus privilegios si los productos afectados no est\u00e1n instalados en su ruta (path) de acceso predeterminada (\\\"C:\\\\Program Files\\\\*\\\" o el equivalente localizado).\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":6.4,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.5,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:M/Au:N/C:C/I:C/A:C\",\"accessVector\":\"LOCAL\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\",\"baseScore\":6.9},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.4,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-254\"},{\"lang\":\"en\",\"value\":\"CWE-284\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:primary_setup_tool:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8046A64D-4C80-4199-B1A7-F77D02428ACD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:security_configuration_tool:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C33765E4-619E-4566-BF96-4A7C8776A0CB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_it_production_suite:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DBCAF7A5-CA65-4D88-8473-67947726CA2D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_net_pc_software:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"14.0\",\"matchCriteriaId\":\"87DF85DE-B86C-459A-A9A9-096AF7A661E6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.1\",\"matchCriteriaId\":\"4DFBFF6B-DBC8-451D-A235-4C7E1F0883D5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E8B894F4-9635-4436-BC0A-E43280426017\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs7:8.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"172A6A81-C32E-4ACC-AB8C-2014BF3A6901\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs7:8.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8C6E8BBF-C5FF-4F13-AC70-2FF41CF3CC8E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_step_7:*:sp4:*:*:*:*:*:*\",\"versionEndIncluding\":\"5.5\",\"matchCriteriaId\":\"C60C6533-1875-4E5B-A367-F6C1C1345CCF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_step_7_\\\\(tia_portal\\\\):*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"14.0\",\"matchCriteriaId\":\"A4053231-D271-4A23-B0A0-374F6EAE2EF8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_winac_rtx_2010:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AD93D757-C2DE-444C-9FF4-A7A700EFF7F0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_winac_rtx_f_2010:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"042D7AB5-8DB7-478E-8CB8-31942D360B34\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:*:sp2:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.0\",\"matchCriteriaId\":\"B9D3442E-E362-49BA-8699-629A611A6E2E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.0:sp3:*:*:*:*:*:*\",\"matchCriteriaId\":\"0D0BB2E6-1444-499A-943E-8D19C402F1BD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4C4BFBED-E818-453C-B787-22D67B4A5A29\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8D6229A2-9B8E-4F76-8425-589D2CE58B16\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F64B795A-7E66-49AE-BE40-E8EEAC12D280\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_\\\\(tia_portal\\\\):*:*:*:*:advanced:*:*:*\",\"versionEndIncluding\":\"14.0\",\"matchCriteriaId\":\"882F53D9-7AAA-4647-B071-A45CA2618AA1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_\\\\(tia_portal\\\\):*:*:*:*:basic:*:*:*\",\"versionEndIncluding\":\"14.0\",\"matchCriteriaId\":\"F4524CA7-833B-4577-A5E5-DB47704F49AF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_\\\\(tia_portal\\\\):*:*:*:*:comfort:*:*:*\",\"versionEndIncluding\":\"14.0\",\"matchCriteriaId\":\"58782A2B-6A27-475A-9FAB-0272DED5DB40\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_\\\\(tia_portal\\\\):-:*:*:*:professional:*:*:*\",\"matchCriteriaId\":\"D9BA6A34-593E-466A-B11B-1E2DC890ECF6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:professional:*:*:*\",\"matchCriteriaId\":\"E6BFBAED-EE2B-4DE4-A76C-824DD15F4608\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simit:9.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"939DE56D-D8D7-42B8-BC0C-D6727E99AFA3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinema_remote_connect:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9646F056-080A-4F45-AABD-4D6E8AF05148\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinema_server:*:sp2:*:*:*:*:*:*\",\"versionEndIncluding\":\"13.0\",\"matchCriteriaId\":\"3F8B6E52-C339-41B9-A2C1-A6D161251648\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:softnet_security_client:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"5.0\",\"matchCriteriaId\":\"18BFF869-4E4E-4410-91F7-56A7E959C0FE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:telecontrol_basic:*:sp2:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.0\",\"matchCriteriaId\":\"A9386816-33A5-4DA7-931B-841AAE40E3BE\"}]}]}],\"references\":[{\"url\":\"http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/94158\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.