Search criteria
6 vulnerabilities found for simatic_pc-station_plus_firmware by siemens
FKIE_CVE-2022-47375
Vulnerability from fkie_nvd - Published: 2023-12-12 12:15 - Updated: 2024-11-21 07:31
Severity ?
Summary
A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly.
This could allow an attacker to create a buffer overflow and create a denial of service condition for the device.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:6es7412-2ek07-0ab0_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B9F039A6-AD1F-489C-9928-147973AE8DF3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:6es7412-2ek07-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "363D7EEE-9AC0-40D9-9C0A-2B098D152230",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:6es7414-3em07-0ab0_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "257AB2BE-EA5A-47D0-9677-D00FF682C170",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:6es7414-3em07-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "438FDBD7-1731-4D1B-ABA6-76F376054F07",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:6es7414-3fm07-0ab0_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0622ACDF-D82B-487C-84DF-75853A88184C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:6es7414-3fm07-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "23B55825-D285-459F-AB82-110EC58D583C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:6es7416-3es07-0ab0_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "268D8CA8-92BD-40BE-BCB0-8EBA4B724381",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:6es7416-3es07-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "877F922F-D395-4123-B4C2-DCA7D699EB22",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:6es7416-3fs07-0ab0_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1031CEF8-0F66-452E-8E79-BC4A5EDDB10E",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:6es7416-3fs07-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DDA99580-AF0C-4837-B4DB-593C5A045129",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:6ag1414-3em07-7ab0_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "228593D4-10E2-4345-85F5-FE69E68722A3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:6ag1414-3em07-7ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D2066A76-56E4-41C4-9057-F1697B9ADAFE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:6ag1416-3es07-7ab0_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BD7B48F6-B94E-4B65-A2A9-2B5BB333415B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:6ag1416-3es07-7ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "41422165-ABEF-4F09-9E39-C4F89497894B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CDA8B933-D7E3-4E3B-AA1D-75AFC89EA730",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:*:*:*:*:*:*:*",
"matchCriteriaId": "D61A6DA0-1328-4D6F-80A1-2A7CE369A7C9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.8:*:*:*:*:*:*:*",
"matchCriteriaId": "B46F2FCA-845B-4E65-AF8C-B924E55921B3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.9:*:*:*:*:*:*:*",
"matchCriteriaId": "0CD43CE2-ED05-4BBF-9553-04AB07D33F50",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.0:*:*:*:*:*:*:*",
"matchCriteriaId": "DB8DD275-D4EA-426C-8611-C2083036A799",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.1:sp1:*:*:*:*:*:*",
"matchCriteriaId": "9EB60A1E-ABE0-4A1C-A2F0-C77E59DCF577",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.1:sp1_hotfix1:*:*:*:*:*:*",
"matchCriteriaId": "03224943-DCAF-4203-90BD-A6100745A3A8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.1:sp1_hotfix13:*:*:*:*:*:*",
"matchCriteriaId": "59460788-9C30-444F-B0F5-B2ACB7B5CDCD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:-:*:*:*:*:*:*",
"matchCriteriaId": "6622AE2E-81B0-419C-8C37-A7C56FB92745",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:hotfix1:*:*:*:*:*:*",
"matchCriteriaId": "D8DFFEC3-B48B-4B47-83E4-B73383003F68",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:hotfix11:*:*:*:*:*:*",
"matchCriteriaId": "10596147-76C0-4626-987B-AECA3D359C9F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:hotfix7:*:*:*:*:*:*",
"matchCriteriaId": "4B6DEC37-63E1-479C-91C5-A5339E5F4FAB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3:*:*:*:*:*:*",
"matchCriteriaId": "AD9434B6-29F3-445C-A3CA-57E2230622EA",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix1:*:*:*:*:*:*",
"matchCriteriaId": "284207F1-E83D-4D32-8D0C-5D20126D0B11",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix13:*:*:*:*:*:*",
"matchCriteriaId": "95DC883D-5792-4ECD-9A19-D97173FD2D96",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix6:*:*:*:*:*:*",
"matchCriteriaId": "7ADD4FD1-F3E2-480A-AE4E-747AA744F8D6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix9:*:*:*:*:*:*",
"matchCriteriaId": "E9DF3564-63E8-4B17-A2CD-799954C31B42",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_pc-station_plus_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0EA49005-5CEB-4AC5-8E3A-6400650C4F1A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_pc-station_plus:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D170B645-158D-443D-A565-FC44663DEA16",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC\u00a0PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions \u003c V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly.\r\n\r\nThis could allow an attacker to create a buffer overflow and create a denial of service condition for the device."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en:\nSIMATIC PC-Station Plus (todas las versiones), \nSIMATIC S7-400 CPU 412-2 PN V7 (todas las versiones), \nSIMATIC S7-400 CPU 414-3 PN/DP V7 (todas las versiones), \nSIMATIC S7 -400 CPU 414F-3 PN/DP V7 (todas las versiones), \nSIMATIC S7-400 CPU 416-3 PN/DP V7 (todas las versiones), \nSIMATIC S7-400 CPU 416F-3 PN/DP V7 (todas las versiones), \nSINAMICS S120 (incl. variantes SIPLUS) (todas las versiones \u0026lt; V5.2 SP3 HF15), \nSIPLUS S7-400 CPU 414-3 PN/DP V7 (todas las versiones), \nSIPLUS S7-400 CPU 416-3 PN/DP V7 (todas las versiones) ). \nLos productos afectados no manejan correctamente los nombres de archivos largos. Esto podr\u00eda permitir a un atacante crear un desbordamiento del b\u00fafer y crear una condici\u00f3n de denegaci\u00f3n de servicio para el dispositivo."
}
],
"id": "CVE-2022-47375",
"lastModified": "2024-11-21T07:31:51.270",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "productcert@siemens.com",
"type": "Primary"
}
]
},
"published": "2023-12-12T12:15:10.797",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-805"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2022-47374
Vulnerability from fkie_nvd - Published: 2023-12-12 12:15 - Updated: 2024-11-21 07:31
Severity ?
Summary
A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly.
This could allow an attacker to exhaust system resources and create a denial of service condition for the device.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:6es7412-2ek07-0ab0_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B9F039A6-AD1F-489C-9928-147973AE8DF3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:6es7412-2ek07-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "363D7EEE-9AC0-40D9-9C0A-2B098D152230",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:6es7414-3em07-0ab0_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "257AB2BE-EA5A-47D0-9677-D00FF682C170",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:6es7414-3em07-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "438FDBD7-1731-4D1B-ABA6-76F376054F07",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:6es7414-3fm07-0ab0_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0622ACDF-D82B-487C-84DF-75853A88184C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:6es7414-3fm07-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "23B55825-D285-459F-AB82-110EC58D583C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:6es7416-3es07-0ab0_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "268D8CA8-92BD-40BE-BCB0-8EBA4B724381",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:6es7416-3es07-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "877F922F-D395-4123-B4C2-DCA7D699EB22",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:6es7416-3fs07-0ab0_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1031CEF8-0F66-452E-8E79-BC4A5EDDB10E",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:6es7416-3fs07-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DDA99580-AF0C-4837-B4DB-593C5A045129",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:6ag1414-3em07-7ab0_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "228593D4-10E2-4345-85F5-FE69E68722A3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:6ag1414-3em07-7ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D2066A76-56E4-41C4-9057-F1697B9ADAFE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:6ag1416-3es07-7ab0_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BD7B48F6-B94E-4B65-A2A9-2B5BB333415B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:6ag1416-3es07-7ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "41422165-ABEF-4F09-9E39-C4F89497894B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CDA8B933-D7E3-4E3B-AA1D-75AFC89EA730",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:*:*:*:*:*:*:*",
"matchCriteriaId": "D61A6DA0-1328-4D6F-80A1-2A7CE369A7C9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.8:*:*:*:*:*:*:*",
"matchCriteriaId": "B46F2FCA-845B-4E65-AF8C-B924E55921B3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.9:*:*:*:*:*:*:*",
"matchCriteriaId": "0CD43CE2-ED05-4BBF-9553-04AB07D33F50",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.0:*:*:*:*:*:*:*",
"matchCriteriaId": "DB8DD275-D4EA-426C-8611-C2083036A799",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.1:sp1:*:*:*:*:*:*",
"matchCriteriaId": "9EB60A1E-ABE0-4A1C-A2F0-C77E59DCF577",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.1:sp1_hotfix1:*:*:*:*:*:*",
"matchCriteriaId": "03224943-DCAF-4203-90BD-A6100745A3A8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.1:sp1_hotfix13:*:*:*:*:*:*",
"matchCriteriaId": "59460788-9C30-444F-B0F5-B2ACB7B5CDCD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:-:*:*:*:*:*:*",
"matchCriteriaId": "6622AE2E-81B0-419C-8C37-A7C56FB92745",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:hotfix1:*:*:*:*:*:*",
"matchCriteriaId": "D8DFFEC3-B48B-4B47-83E4-B73383003F68",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:hotfix11:*:*:*:*:*:*",
"matchCriteriaId": "10596147-76C0-4626-987B-AECA3D359C9F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:hotfix7:*:*:*:*:*:*",
"matchCriteriaId": "4B6DEC37-63E1-479C-91C5-A5339E5F4FAB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3:*:*:*:*:*:*",
"matchCriteriaId": "AD9434B6-29F3-445C-A3CA-57E2230622EA",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix1:*:*:*:*:*:*",
"matchCriteriaId": "284207F1-E83D-4D32-8D0C-5D20126D0B11",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix13:*:*:*:*:*:*",
"matchCriteriaId": "95DC883D-5792-4ECD-9A19-D97173FD2D96",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix6:*:*:*:*:*:*",
"matchCriteriaId": "7ADD4FD1-F3E2-480A-AE4E-747AA744F8D6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix9:*:*:*:*:*:*",
"matchCriteriaId": "E9DF3564-63E8-4B17-A2CD-799954C31B42",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_pc-station_plus_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0EA49005-5CEB-4AC5-8E3A-6400650C4F1A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_pc-station_plus:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D170B645-158D-443D-A565-FC44663DEA16",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC\u00a0PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions \u003c V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly.\r\n\r\nThis could allow an attacker to exhaust system resources and create a denial of service condition for the device."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en:\nSIMATIC PC-Station Plus (todas las versiones), \nSIMATIC S7-400 CPU 412-2 PN V7 (todas las versiones), \nSIMATIC S7-400 CPU 414-3 PN/DP V7 (todas las versiones), \nSIMATIC S7 -400 CPU 414F-3 PN/DP V7 (todas las versiones), \nSIMATIC S7-400 CPU 416-3 PN/DP V7 (todas las versiones), \nSIMATIC S7-400 CPU 416F-3 PN/DP V7 (todas las versiones), \nSINAMICS S120 (incl. variantes SIPLUS) (todas las versiones \u0026lt; V5.2 SP3 HF15), \nSIPLUS S7-400 CPU 414-3 PN/DP V7 (todas las versiones), \nSIPLUS S7-400 CPU 416-3 PN/DP V7 (todas las versiones) ). \nLos productos afectados no manejan correctamente las solicitudes HTTP(S) al servidor web. Esto podr\u00eda permitir que un atacante agote los recursos del sistema y cree una condici\u00f3n de denegaci\u00f3n de servicio para el dispositivo."
}
],
"id": "CVE-2022-47374",
"lastModified": "2024-11-21T07:31:51.127",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "productcert@siemens.com",
"type": "Primary"
}
]
},
"published": "2023-12-12T12:15:10.563",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-674"
}
],
"source": "productcert@siemens.com",
"type": "Primary"
}
]
}
CVE-2022-47375 (GCVE-0-2022-47375)
Vulnerability from cvelistv5 – Published: 2023-12-12 11:25 – Updated: 2024-08-03 14:55
VLAI?
Summary
A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly.
This could allow an attacker to create a buffer overflow and create a denial of service condition for the device.
Severity ?
CWE
- CWE-805 - Buffer Access with Incorrect Length Value
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC PC-Station Plus |
Affected:
All versions
|
||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:55:07.916Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0PC-Station Plus",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 412-2 PN V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2 SP3 HF15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC\u00a0PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions \u003c V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly.\r\n\r\nThis could allow an attacker to create a buffer overflow and create a denial of service condition for the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-805",
"description": "CWE-805: Buffer Access with Incorrect Length Value",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-12T11:25:32.533Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-47375",
"datePublished": "2023-12-12T11:25:32.533Z",
"dateReserved": "2022-12-13T14:51:37.210Z",
"dateUpdated": "2024-08-03T14:55:07.916Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-47374 (GCVE-0-2022-47374)
Vulnerability from cvelistv5 – Published: 2023-12-12 11:25 – Updated: 2024-08-03 14:55
VLAI?
Summary
A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly.
This could allow an attacker to exhaust system resources and create a denial of service condition for the device.
Severity ?
CWE
- CWE-674 - Uncontrolled Recursion
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC PC-Station Plus |
Affected:
All versions
|
||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:55:07.699Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0PC-Station Plus",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 412-2 PN V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2 SP3 HF15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC\u00a0PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions \u003c V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly.\r\n\r\nThis could allow an attacker to exhaust system resources and create a denial of service condition for the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-674",
"description": "CWE-674: Uncontrolled Recursion",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-12T11:25:31.314Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-47374",
"datePublished": "2023-12-12T11:25:31.314Z",
"dateReserved": "2022-12-13T14:51:37.209Z",
"dateUpdated": "2024-08-03T14:55:07.699Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-47375 (GCVE-0-2022-47375)
Vulnerability from nvd – Published: 2023-12-12 11:25 – Updated: 2024-08-03 14:55
VLAI?
Summary
A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly.
This could allow an attacker to create a buffer overflow and create a denial of service condition for the device.
Severity ?
CWE
- CWE-805 - Buffer Access with Incorrect Length Value
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC PC-Station Plus |
Affected:
All versions
|
||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:55:07.916Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0PC-Station Plus",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 412-2 PN V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2 SP3 HF15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC\u00a0PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions \u003c V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly.\r\n\r\nThis could allow an attacker to create a buffer overflow and create a denial of service condition for the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-805",
"description": "CWE-805: Buffer Access with Incorrect Length Value",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-12T11:25:32.533Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-47375",
"datePublished": "2023-12-12T11:25:32.533Z",
"dateReserved": "2022-12-13T14:51:37.210Z",
"dateUpdated": "2024-08-03T14:55:07.916Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-47374 (GCVE-0-2022-47374)
Vulnerability from nvd – Published: 2023-12-12 11:25 – Updated: 2024-08-03 14:55
VLAI?
Summary
A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly.
This could allow an attacker to exhaust system resources and create a denial of service condition for the device.
Severity ?
CWE
- CWE-674 - Uncontrolled Recursion
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC PC-Station Plus |
Affected:
All versions
|
||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:55:07.699Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0PC-Station Plus",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 412-2 PN V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2 SP3 HF15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC\u00a0PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions \u003c V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly.\r\n\r\nThis could allow an attacker to exhaust system resources and create a denial of service condition for the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-674",
"description": "CWE-674: Uncontrolled Recursion",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-12T11:25:31.314Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-47374",
"datePublished": "2023-12-12T11:25:31.314Z",
"dateReserved": "2022-12-13T14:51:37.209Z",
"dateUpdated": "2024-08-03T14:55:07.699Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}