Vulnerabilites related to siemens - simatic_s7-1200_cpu_firmware
Vulnerability from fkie_nvd
Published
2019-10-10 14:15
Modified
2024-11-21 04:20
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Affected devices improperly handle large amounts of specially crafted UDP packets.
This could allow an unauthenticated remote attacker to trigger a denial of service condition.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E19343EA-5ECA-4263-A568-DAEA04425F86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*", "matchCriteriaId": "53DF35F1-94FF-4D0B-9FA2-E8B0AFAEA5FF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ek-ertec_200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "70D5CDF4-A134-402E-A4E9-4BBA19082397", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ek-ertec_200:-:*:*:*:*:*:*:*", "matchCriteriaId": "B47CF3BB-08E4-4B86-B793-8253C172D846", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2773F4B7-095E-4A33-93F2-765FA58B828C", "versionEndExcluding": "4.6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:4.6:-:*:*:*:*:*:*", "matchCriteriaId": "9E7753EE-DF23-4838-B3B4-7C43C550519C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*", "matchCriteriaId": "FB75CD44-5223-40A7-A835-111BF3C25D23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ABA8C0E5-E6AA-4BF2-925F-0041C382A416", "versionEndExcluding": "1.2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*", "matchCriteriaId": "B6C1E4CC-2657-4383-83D8-5C8F88B12755", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "24E01824-4942-4400-A8C2-43A5772C2968", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*", "matchCriteriaId": "34C17B00-34B5-4A15-9333-252BE2975F37", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "14E56570-5C20-40BD-BF0B-F6ED06AFC8F7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*", "matchCriteriaId": "7037E46B-4FE5-4693-B6A6-B5AF7B652C4F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_ba_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4458E08-9864-452E-B95E-A46C5600D488", "versionEndExcluding": "4.3.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_ba:-:*:*:*:*:*:*:*", "matchCriteriaId": "9AF349D2-2560-4C60-8729-4B6CCDC52347", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_hf_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "00743200-D240-4CBC-8652-555F5E89B042", "versionEndExcluding": "4.4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_hf:-:*:*:*:*:*:*:*", "matchCriteriaId": "AB9BFB03-D366-4F23-9477-D6133BD021CF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_st_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACDF9AF3-DDB9-41A8-90C5-2A95A51D5EDE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_st:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B48C0A4-072A-4744-94A5-FC4741F4A029", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BB063929-AAB0-4FF8-BCA3-71BA80517B1A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1EC40E7-F004-446C-B5C9-0AB9911105E0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_ba_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8A1327FC-E785-4AA7-BC73-CC61CEED832D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_ba:-:*:*:*:*:*:*:*", "matchCriteriaId": "4C0300D2-1A87-4F61-9444-C1D23E3E6033", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_ha_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "17B7ED41-6AC7-4D34-A94E-61AECFA088EA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_ha:-:*:*:*:*:*:*:*", "matchCriteriaId": "34131306-1591-42B3-B235-4265F918CBDA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_hf_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "67DAE64A-6E78-452E-9812-242769378ED8", "versionEndExcluding": "4.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_hf:-:*:*:*:*:*:*:*", "matchCriteriaId": "527AE806-5C00-4C44-940F-88032AD8120D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_hs_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AAAA8667-C792-45E4-AE5E-C194B5B76366", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_hs:-:*:*:*:*:*:*:*", "matchCriteriaId": "455EC7E5-236B-43E6-86E7-702FAFCCCB15", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_st_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "918CBE10-D912-446B-B8B3-843B0089CB7A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_st:-:*:*:*:*:*:*:*", "matchCriteriaId": "1DB6FAE7-8598-4673-83A9-7A838BB207C5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn\\/2_hf_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6269D1CC-FF57-409F-8284-C95FF4DCEF25", "versionEndExcluding": "4.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn\\/2_hf:-:*:*:*:*:*:*:*", "matchCriteriaId": "2CBAACFE-CD21-4FAC-9262-1A7F325D6E40", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn\\/3_hf_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3FA7253F-17B9-411B-B4C9-FE51DF0DE44D", "versionEndExcluding": "4.2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn\\/3_hf:-:*:*:*:*:*:*:*", "matchCriteriaId": "DCCAFEF7-CA0C-4F20-B98E-DBB8365F1CCF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3EE0B998-E408-408F-8F78-5E90F74E9C9B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*", "matchCriteriaId": "0259EAE9-0CA0-49A5-A573-8339604A181B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D054139B-BE36-4B34-88AE-BC487DCB1DCB", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "3F0CE2EC-9A73-4576-A389-A19893D47B0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F14E991-8DF6-4221-A9BF-E13EEF211220", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE84D161-BA23-422A-8959-CF047834A631", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6230347-9AAE-424F-A46F-4A714BA0823D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A1A44BC-15CC-4CC1-A9D0-4B04233B80CE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "54EFA8B5-8DA1-4547-9E15-BDC265C56006", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "B1CEB200-E38F-4629-9279-5AF065396678", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "87B14F05-4D54-420F-8393-4AB27EF6A7D1", "versionEndExcluding": "4.2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler:-:*:*:*:*:*:*:*", "matchCriteriaId": "49FB85F8-7D45-433E-805B-360725F2980C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_profinet_driver_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05248152-94EB-4978-98A7-B1A393CA1F03", "versionEndExcluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*", "matchCriteriaId": "526493E9-EF74-4836-9A8F-134B625035AA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2BA63AED-84E4-4F92-A4D4-0713E7F65C4A", "versionEndExcluding": "4.4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "F2B63726-10CE-46AB-ADBA-A511E770E162", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D81B519-6FE9-405C-8BB1-57D14AF531E5", "versionEndExcluding": "4.4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*", "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "84E0444D-01E0-4F7A-81A0-314C0F7FA623", "versionEndExcluding": "4.4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*", "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B980BB8C-9AFE-45E4-A4D4-AB555B234059", "versionEndExcluding": "4.4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*", "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BD6FB801-AE4C-4EDF-96CC-33A4CD51165A", "versionEndExcluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "01048F7F-9C5B-47C0-AE16-321FCA670F3D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500s_cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D5DE5B3D-13B1-4684-8859-C3FB34FE50CF", "versionEndExcluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500s_cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "B82EADBC-AECE-45B4-AF95-6F0D84966E67", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500t_cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF5E4914-A5EA-451C-9FAF-751B74B8BC69", "versionEndExcluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500t_cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "4BE2F683-2A24-4152-9A07-00B0117C5F12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7B6777DC-80B5-4B36-B9AA-DA764C8016F7", "versionEndExcluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*", "matchCriteriaId": "BE0BA68C-EB57-49CE-94A8-E7905AB79824", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "55490E3D-616D-4D21-BAC2-29A51CB067E9", "versionEndExcluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*", "matchCriteriaId": "822894D4-96D5-4BDC-A698-D31262BCF422", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "45303F50-046B-4621-AC6D-2B6E17D948C3", "versionEndExcluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*", "matchCriteriaId": "D2E24A4C-AC13-4382-BDF6-E13878FED4DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C87674A8-B518-4910-B03D-FFF4D5A7B627", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "602FB384-0DB2-488C-B3CC-96E3A2882976", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_312_ifm_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7B0C6327-7BF6-4B96-82A8-D750007869EE", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_312_ifm:-:*:*:*:*:*:*:*", "matchCriteriaId": "CCFCAA2B-71FE-4DB4-B8B0-F5FD1254C331", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_313_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3EF9F3FB-FBBA-42A8-9A90-FE34703274B5", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_313:-:*:*:*:*:*:*:*", "matchCriteriaId": "4E6E900F-63C1-4E50-9DCD-26CE760E5275", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8F2F0659-CD37-4AA9-B7D5-44639515533C", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*", "matchCriteriaId": "78399465-EED5-4EBD-A2E1-6FE0BD01EDB4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_ifm_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "07AD63B6-B05C-4BBF-812D-379C4D8F8CC7", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314_ifm:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BE7963C-7AFF-495B-9F0B-28FB393443FD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F2A0C75-E360-4E3D-85DA-878E39054E26", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315:-:*:*:*:*:*:*:*", "matchCriteriaId": "E3962681-E32E-4BD1-8C71-8768248691D4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "488F0774-43DA-455D-905C-C514A0192260", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "E8FD8E6D-0527-4215-B6F0-5824011433FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_316-2_dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F103C351-99C9-4F7D-B69A-D8A876F57504", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_316-2_dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "644AD6A8-AEDE-4F1C-92F8-836877A81310", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_318-2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA99549B-5E95-445A-A95B-1CDA7014686B", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_318-2:-:*:*:*:*:*:*:*", "matchCriteriaId": "FF58C652-E74D-4B57-A7C5-08D7446863D5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400_pn_v7_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B6B9D8B-D7BA-4D72-97C7-7BBEB49802F7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_pn_v7:-:*:*:*:*:*:*:*", "matchCriteriaId": "E4F8215E-E737-4CD5-B7D9-57FE4A2A2FE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400_dp_v7_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72F7B870-35A1-4900-8104-1303F291E29A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_dp_v7:-:*:*:*:*:*:*:*", "matchCriteriaId": "ABE9F7D2-22C7-4E7C-99C3-4A88CDD2CDB7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400_v6_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7A4C79A5-96BB-4ADB-B28A-C9C48B195F49", "versionEndExcluding": "6.0.9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_v6:-:*:*:*:*:*:*:*", "matchCriteriaId": "A6445275-2AEF-4285-BE7A-67F20182481C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE93A33C-7007-4908-868A-4FBE4D073E57", "versionEndExcluding": "6.0.9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*", "matchCriteriaId": "1D082EB6-3C13-40C1-9949-179DC59037C1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63EA1886-A72E-48A7-B99F-C236BF6992FA", "versionEndExcluding": "8.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*", "matchCriteriaId": "926D9DCF-A7EA-416A-9A07-122D1FCA027B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9D03BD73-51ED-42E0-A552-C32BB7A935B2", "versionEndExcluding": "2010", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:2010:-:*:*:*:*:*:*", "matchCriteriaId": "7151A19C-0AE5-4F66-9E3D-8BF675A8430C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\)_2010:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6034789-ABD1-4035-8378-F0BA7157B087", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "84B1F9B1-4248-4A4C-A8BB-77475A0E9B9B", "versionEndExcluding": "1.5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.5:-:*:*:*:*:*:*", "matchCriteriaId": "F2F99FFB-C312-4080-9580-84AFB7C9FA09", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1A43D34-ECA3-4330-B85F-02BDD1D22149", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "83803F1C-4842-43BB-B903-C2E91FF7DC08", "versionEndExcluding": "1.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*", "matchCriteriaId": "B75F50CA-7371-4BC7-8D8A-13F8BC69E4EB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "775C90BB-C026-435C-889A-517EF85656C5", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "CAA92AC6-7DA0-418D-A13F-69268DFD7966", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*", "matchCriteriaId": "D61D3E9C-1346-4354-BCD9-B02F67500C41", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B1DBCA1A-27F3-4E9A-9F89-65E82A68DE4A", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_g120_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "94CB2F3E-AAA1-4472-BFD4-4E6E1B663FF5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*", "matchCriteriaId": "61A60DCE-384B-43A4-A669-973FB8ECA932", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "856768D2-C096-4CA7-B26F-E94B005C0D79", "versionEndExcluding": "5.2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:5.2:-:*:*:*:*:*:*", "matchCriteriaId": "AD0515D7-829B-4591-95D9-94C3982FD727", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*", "matchCriteriaId": "373DBE44-AC28-4D04-93BB-35CD8C60E899", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C579C2C7-0402-46B2-A770-C3B7F71D1096", "versionEndExcluding": "5.2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:5.2:-:*:*:*:*:*:*", "matchCriteriaId": "255A153A-A6A0-46A4-A7CF-01D0D09761C7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2296CA65-0E89-4BCB-8003-E7212BF1F585", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3653DA37-DB23-41E0-8CE8-838E384AA40A", "versionEndExcluding": "4.8", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*", "matchCriteriaId": "0F86A334-10F9-4DFB-A421-CBCAFD86C8C2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E25804D-D943-4C2A-9C78-AAC61F7BA4FF", "versionEndExcluding": "4.8", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.8:-:*:*:*:*:*:*", "matchCriteriaId": "06B69CD4-3AEC-4014-81DB-33805A44A5D3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s110_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "243FFEA3-7193-45EA-B865-E9CA1D6656FE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*", "matchCriteriaId": "6218802E-D3B1-4197-A6B5-7343A50F7D88", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "03F9CBC3-B2B3-4FA7-963D-A8F3AE6D8EA0", "versionEndExcluding": "5.2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:-:*:*:*:*:*:*", "matchCriteriaId": "6622AE2E-81B0-419C-8C37-A7C56FB92745", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*", "matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6BF989EE-CD8D-450D-90F6-FD15F00B59B9", "versionEndExcluding": "5.2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:5.2:-:*:*:*:*:*:*", "matchCriteriaId": "EFFDE2CB-684D-4ECE-A104-F355254A46B9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D48682C-A39D-4A09-B904-50FA64A9D2A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "30E52510-9306-42B8-A517-A6BBD34B8B9D", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "58A71910-E54F-426B-BAB1-260AEFD8EF6E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "28DB0BC6-E60A-4798-80DC-125EF25B3A40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:sinumerik_828d:*:*:*:*:*:*:*:*", "matchCriteriaId": "328F0192-B34D-481C-8964-226317439966", "versionEndExcluding": "4.8", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:-:*:*:*:*:*:*", "matchCriteriaId": "C7936CF6-DC07-4550-9FEC-823A2F49096D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp1:*:*:*:*:*:*", "matchCriteriaId": "BEE7D914-F2DE-4D8C-BFB2-7AD16650CD3F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp2:*:*:*:*:*:*", "matchCriteriaId": "BDBAEDBC-6A76-495D-9BC7-BA687F32EE40", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp3:*:*:*:*:*:*", "matchCriteriaId": "45EF769B-1EB1-4D2D-84C5-8005EF1EE1EF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp4:*:*:*:*:*:*", "matchCriteriaId": "48EE5859-5450-4078-94E7-E525B999A837", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:sinumerik_840d_sl:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FFC86D6-F312-4097-91A6-79C78502323F", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Affected devices improperly handle large amounts of specially crafted UDP packets.\r\n\r\nThis could allow an unauthenticated remote attacker to trigger a denial of service condition." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Kits de desarrollo/evaluaci\u00f3n para PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. variantes SIPLUS), SIMATIC ET200AL, SIMATIC ET200M (incl. variantes SIPLUS), SIMATIC ET200MP IM155-5 PN BA (incl. variantes SIPLUS), SIMATIC ET200MP IM155-5 PN HF (incl. variantes SIPLUS), SIMATIC ET200MP IM155-5 PN ST (incl. variantes SIPLUS) SIPLUS), SIMATIC ET200S (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN BA (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HA (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HS (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN ST (incl. variantes SIPLUS). SIPLUS), SIMATIC ET200SP IM155-6 PN/2 HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN/3 HF (incl. variantes SIPLUS) variantes SIPLUS), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200pro, paneles exteriores SIMATIC HMI Comfort de 7\" y 15\" (incl. variantes SIPLUS), paneles SIMATIC HMI Comfort de 4\" a 22\" (incl. variantes SIPLUS), paneles m\u00f3viles SIMATIC HMI KTP, acoplador SIMATIC PN/PN (incl. variantes SIPLUS NET), driver SIMATIC PROFINET, familia de CPUs SIMATIC S7-1200 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-1500 (incl. variantes SIPLUS). CPUs ET200 y variantes SIPLUS), SIMATIC S7-1500 Software Controller, familia de CPUs SIMATIC S7-300 (incl. CPUs ET200 y variantes SIPLUS), familia de CPUs SIMATIC S7-400 H V6 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V6 e inferiores (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V7 (incl. variantes SIPLUS), SIMATIC S7-400 PN/DP V7 (incl. variantes SIPLUS). SIPLUS), familia de CPU SIMATIC S7-410 V8 (incl. variantes SIPLUS), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4. 7 PN Control Unit, SINAMICS G120 V4.7 PN Control Unit (incl. variantes SIPLUS), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4. 7, SINAMICS GL150 V4.7, SINAMICS GM150 V4.7, SINAMICS S110, SINAMICS S120 V4.7 (incluidas las variantes SIPLUS), SINAMICS S150, SINAMICS SL150 V4.7, SINAMICS SM120 V4.7, SINUMERIK 828D, SINUMERIK 840D sl. Los dispositivos afectados contienen una vulnerabilidad que permite a un atacante no autenticado desencadenar una condici\u00f3n de denegaci\u00f3n de servicio. La vulnerabilidad puede activarse si se env\u00eda al dispositivo una gran cantidad de paquetes UDP especialmente dise\u00f1ados. La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante con acceso a la red de los sistemas afectados. La explotaci\u00f3n exitosa no requiere privilegios del sistema ni interacci\u00f3n del usuario. Un atacante podr\u00eda utilizar la vulnerabilidad para comprometer la disponibilidad del dispositivo. En el momento de la publicaci\u00f3n del aviso no se conoc\u00eda ninguna explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad" } ], "id": "CVE-2019-10936", "lastModified": "2024-11-21T04:20:11.257", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2019-10-10T14:15:14.707", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-09-12 10:15
Modified
2024-11-21 07:56
Severity ?
Summary
The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation.
This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cloud_connect_7_cc712_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A6A6E437-2948-4327-957A-E027B0CBDC9F", "versionEndExcluding": "2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cloud_connect_7_cc712:-:*:*:*:*:*:*:*", "matchCriteriaId": "401AE283-A410-40EC-A5B8-EE61D7A05B0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cloud_connect_7_cc716_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D2FE4F4B-F241-42F0-B0FF-0D2EA5D2A861", "versionEndExcluding": "2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cloud_connect_7_cc716:-:*:*:*:*:*:*:*", "matchCriteriaId": "3AE3854B-8B04-497B-81EF-5CC46EE8C5F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1504d_tf_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F0DD4318-C5B6-4FA1-AFEC-5B94D4387C90", "versionEndExcluding": "2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1504d_tf:-:*:*:*:*:*:*:*", "matchCriteriaId": "D3A69023-E9FF-4947-81D2-5374F0D17E02", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1507d_tf_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F31BACB-100A-4BF4-BD1E-258239B68BD8", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1507d_tf:-:*:*:*:*:*:*:*", "matchCriteriaId": "F6D49FAA-BB5E-4B55-9C11-B840676FEC97", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9BBF8055-0E33-48FB-B1C7-2464E88F6F0B", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "D4272246-E9ED-4D4B-9655-8CA2B28E9A65", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EAFD65C2-BFE4-4085-8BB1-424747A5F1BF", "versionEndExcluding": "3.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "F2B63726-10CE-46AB-ADBA-A511E770E162", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E7C76C8B-5A4E-4C6F-BEEE-D378B58F21F1", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "70F315E1-448F-4A2B-920F-4024BB0F0CE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp_f-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CCA8715D-256C-4773-AB24-80772F29CDEB", "versionEndExcluding": "3.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp_f-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "DE4FA2EC-3630-4AE2-8F1B-008BF8086B79", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "14EFF4D2-A5E6-4394-BB3A-A4C500C3252D", "versionEndExcluding": "21.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "F62F4050-F6C9-4C8F-8E09-F0AEEDB6B1FC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "89F2F119-05F6-4939-9793-1616008F1034", "versionEndExcluding": "30.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "88B6F56A-13A7-4E66-AAF3-6341AEDA5FCB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B5F16F8-1B17-4B87-98BE-1703EC07D538", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "3A3E8A67-2A29-4DE9-AF1B-D74A42D55D1E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511t-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E3510CA-9FD7-4644-90ED-DAB9753BA9C4", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511t-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "695E97F6-9C8B-46E4-BAE1-9BDD4F732C6E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511tf-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7570804A-DFEF-4B1A-B42B-ADD5150D4CF1", "versionEndExcluding": "3.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511tf-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "CD28BC90-7CDF-4DB1-B14A-D6A2B69DEB75", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C5996EB8-C593-4859-AD0F-FE842C777CF0", "versionEndExcluding": "3.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "43447C40-F6CA-47C3-A837-919377107012", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8F4CBA16-6D19-48B9-BC30-92EC713A28B4", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "E692307D-E439-409A-8982-ECE0E6CF6F5E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp_f-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "310BEAFA-C3E6-4D6F-9E55-F1F9B3B39878", "versionEndExcluding": "3.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp_f-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "A61107B4-2EA5-4642-B022-EB75C4B9DAC8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C948AA93-13C3-4EDD-AE77-4547D8930928", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "D6663D66-5127-4F5D-B39D-50D3F88F4435", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "70538CDF-EE35-4667-B808-D05FF69BF464", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "69DE61DE-5B71-4F35-AC4F-C6EC24A7DDAA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513r-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A9583CC-C897-4783-BCA1-E51FD4AD8952", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513r-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "8E5DB6CE-9DFF-4B58-8693-0D9BC80F8686", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1514sp-2_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "46621130-7757-47E0-84BB-4BDE21910E4F", "versionEndExcluding": "3.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1514sp-2_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "3735705B-C196-45C1-B972-5B03D6EBDC87", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1514sp_f-2_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C5DF4E68-CA4B-4D5C-9E66-585210DC94F1", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1514sp_f-2_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "40D98AB8-FD0C-4B31-A732-F10FDEA37E14", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1514spt-2_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FF009EB1-4299-48DF-9DA6-EFDDF7B438E2", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1514spt-2_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "9705BD48-7CA7-45FF-94CB-E21ABF2DADBB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1514spt_f-2_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B51EDCAB-82D4-4400-99AF-33DD01BCB676", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1514spt_f-2_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "F12835A8-D10C-4598-9308-7C053F146DDA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9CD38C29-10B0-44B4-A8EE-1BC104ABF10F", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "ABE9C79B-52A3-45F4-9DA5-6D61A6BF7753", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C5F3CB67-8E02-49ED-9A6A-98D366CF3865", "versionEndExcluding": "3.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "EDE82551-008D-4B75-BDB5-3DD30ADD1863", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515r-2_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CBA0ADBF-BB34-433A-BAC0-EF97606C93C2", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515r-2_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "42957AE0-38CC-47F0-867C-EB161C3AD03B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515t-2_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0CB970C3-5C8A-4972-BD1C-1FE0800C5137", "versionEndExcluding": "3.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515t-2_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF28F388-619A-4B10-AD3D-EA06C56EF22E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515tf-2_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "96ADAF55-5E28-42C5-9399-D8001C3B03A5", "versionEndExcluding": "3.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515tf-2_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "FD64AE8B-79DD-4248-BD98-8AEC260CE87A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4AC215B9-EAB0-4390-89AE-26083D0BA1F0", "versionEndExcluding": "3.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "A5C12961-CCF4-4248-9E43-8866671A257A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "59F0CEB7-D953-4BC3-A736-0492686B760D", "versionEndExcluding": "3.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "5787D689-D80C-47BC-A0C2-E45E0FAD49D9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516t-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EC909775-9D55-4B7E-947D-C7FEA285B3F2", "versionEndExcluding": "3.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516t-3_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "39FC9F4E-6B5E-4A0F-B6F4-22C3D48C649C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516tf-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6746C1CE-D1A3-449A-813E-2DFA498C2F7A", "versionEndExcluding": "3.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516tf-3_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "D233F1F7-6A14-4097-A324-22883A26A55B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "887B13DA-FA2B-4CD7-9225-A81127BBADF6", "versionEndExcluding": "3.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "984F6E53-482D-4282-BBAA-87B0375310FA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "83394CDB-A8BD-40E0-B3F3-40987A2C18D3", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB2327DF-ADA4-453E-A35E-E986D822F1E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517h-3_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "65B8B272-BBFF-41D0-BB27-EF874DC8EF42", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517h-3_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "7063E785-FA7D-44B1-900F-7680304D02D9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517t-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F7ECBA9C-6BA6-4944-A364-36310D1C4D64", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517t-3_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "570F096F-5000-4142-AA21-14DB0832E0B6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517tf-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C613D4D5-AC21-4C78-BE45-E9ABF5F60EC1", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517tf-3_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A70EAB5-1C78-46B0-BD1C-AC9462DA7F5C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E43FA8D7-785C-4925-A6C4-029205955C92", "versionEndExcluding": "21.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "40F38253-92F5-4A3A-AA07-292F7542D8A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66DE7AD2-2A41-46FB-BB29-20B9C5090D10", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BC4FA01-8DDB-41E4-B759-7B504F78AEBC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "16A3F91C-9027-43AB-A597-3C330706B624", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB469732-E3C2-45BC-8F65-C1B6A676A974", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_pn\\/dp_mfp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7A3F5C93-137E-46B1-9534-15C49FAB53D7", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4_pn\\/dp_mfp:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B1EE93D-BAD2-4B86-910C-8784FCC9F398", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518hf-4_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "53767865-28F5-479A-8D0E-B0C90B283EAB", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518hf-4_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "A169C5D6-B3F7-4427-BC64-51F965AB70DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518t-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "87F32A1E-377E-4B69-8940-79A23C9822CB", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518t-4_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "3CECA35C-1BBE-45D5-9CC9-1396D4FFFAC8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518tf-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "77B61B03-E790-46A0-A45D-D73F2D3B3BE2", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518tf-4_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "BCE27319-BAC3-4E45-B6F4-8D37B212C3F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_s7-1518-4_pn\\/dp_odk_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34188D81-DA9B-444D-90D1-AD7F30BD3105", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_s7-1518-4_pn\\/dp_odk:-:*:*:*:*:*:*:*", "matchCriteriaId": "16DB42D7-DA1F-48EC-9EEE-7C34EBBF64E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_s7-1518f-4_pn\\/dp_odk_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C63C680-E1EE-412E-BD95-07D6E3A3F372", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_s7-1518f-4_pn\\/dp_odk:-:*:*:*:*:*:*:*", "matchCriteriaId": "F40A30B3-81A4-4783-9ADF-7C7E77253BD7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_et_200pro_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D3D473D-F0F4-4D08-99EA-A90DF283227F", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_et_200pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "68C4D70C-DAC5-4BC2-977A-BF2DE7C303CC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_software_controller_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FCAEB1E0-BF49-4908-A644-103E6C441C57", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_software_controller:v2:*:*:*:*:*:*:*", "matchCriteriaId": "9B02BF28-415F-4E61-82BA-4A8B9F0B774D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_software_controller_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FCAEB1E0-BF49-4908-A644-103E6C441C57", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_software_controller:v3:*:*:*:*:*:*:*", "matchCriteriaId": "DBAA9122-FB50-4E77-B29F-F313EC3C4E58", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D14775B-EE83-4359-B816-3583A058A21B", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-plcsim_advanced:-:*:*:*:*:*:*:*", "matchCriteriaId": "531A509E-97C9-4838-9E12-7D12DA36616F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cpu_1510sp-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "40C437AF-4533-4FD9-8F10-7C83C6DE759A", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cpu_1510sp-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "A59E3934-8B5D-4AE2-8646-DAE4CAE421D7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cpu_1510sp-1_pn_rail_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2EA83656-90F1-47CD-B7F8-83074D9E7043", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cpu_1510sp-1_pn_rail:-:*:*:*:*:*:*:*", "matchCriteriaId": "173BB9EB-7711-4213-8A0B-71FFFB04A29D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cpu_1510sp_f-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F5AC36D-88D9-41F8-B821-930B0D077468", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cpu_1510sp_f-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "D55AEF55-B481-4B56-92A7-1EDC097C6B89", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cpu_1510sp_f-1_pn_rail_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08DCCA29-255E-4AE8-8695-19F739845318", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cpu_1510sp_f-1_pn_rail:-:*:*:*:*:*:*:*", "matchCriteriaId": "7C7107E7-0C12-4F75-A32E-3EDA5B715E58", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cpu_1512sp-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CDFBE18F-9361-48CA-BAF1-9FCBDB798E24", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cpu_1512sp-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "6DCDF4F3-AA23-42CB-9A48-A0F9CB9F4FE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cpu_1512sp-1_pn_rail_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EDD46CE1-C045-45B6-8836-C6D5ABA949FF", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cpu_1512sp-1_pn_rail:-:*:*:*:*:*:*:*", "matchCriteriaId": "75AE4A3C-B694-4E1F-AED6-3C4E82016084", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cpu_1512sp_f-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AC4F41E9-AB9E-4026-A8B5-5C649A068709", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cpu_1512sp_f-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "79B07E60-4899-4C9B-864A-EC41A43D325D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cpu_1512sp_f-1_pn_rail_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4BF41E57-ED86-4741-A66F-20B61E26CDD8", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cpu_1512sp_f-1_pn_rail:-:*:*:*:*:*:*:*", "matchCriteriaId": "CD37E242-5854-4E06-AD47-5EFB9DF2D013", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1511-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0CFBE515-F390-421A-B8E6-50DF56767E70", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1511-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0EDFA3D-3CB4-4950-8B45-97365BD6140B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1511-1_pn_t1_rail_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8525149F-96FE-4915-84C2-B47622DB12EE", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1511-1_pn_t1_rail:-:*:*:*:*:*:*:*", "matchCriteriaId": "246AF913-84D1-4472-85DE-AFF8A2C3243F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1511-1_pn_tx_rail_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DEEA4FC-9DA6-4316-978F-C25630EEC78B", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1511-1_pn_tx_rail:-:*:*:*:*:*:*:*", "matchCriteriaId": "68490431-0B90-48E6-88BA-8242B01DB763", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1511f-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B7AF5301-6D4B-4683-8778-CEADD79570CE", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1511f-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "88ED741A-80C0-4008-B8DB-88A7A9B625B8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1513-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6EF85A75-9721-41C1-958D-6448F9DCDE29", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1513-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "B8ECE5B2-3C54-4336-BB4B-BBA7B90FC179", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1513f-1_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "95A67D85-8CA3-4639-860E-5F3F5F19F7AE", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1513f-1_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "1C6BEBB1-DB97-4538-A2DE-AE09CBE74E4F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1515f-2_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F6E4250-86E5-4FEF-851E-CCC208695FD9", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1515f-2_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "6844DF63-DFD2-4C4E-A235-B3DD79E81A59", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1515f-2_pn_rail_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1C41AE27-F8AB-4D72-AE93-4B481120868E", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1515f-2_pn_rail:-:*:*:*:*:*:*:*", "matchCriteriaId": "3358ABF2-5371-4DDA-BE8C-466F6D8E2089", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1515f-2_pn_t2_rail_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EECD46E3-1B49-486E-A1F7-823BB57B2723", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1515f-2_pn_t2_rail:-:*:*:*:*:*:*:*", "matchCriteriaId": "12B36AAA-76A3-4CC4-82C2-5FF432AEE52B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1515r-2_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F78B6E0-F7EA-4C3C-B444-65680BE6F22E", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1515r-2_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "52BB0986-D1B5-449F-B399-E28E4B68CA8C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1515r-2_pn_tx_rail_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F99A2902-B756-48EC-9F53-5648FA294F44", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1515r-2_pn_tx_rail:-:*:*:*:*:*:*:*", "matchCriteriaId": "0702D3F7-5604-4DB2-8AD0-EEABFFC50D92", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1516-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "60AD4AE0-0D34-4536-A4DE-DD59C67810BB", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1516-3_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "888F8AC5-103A-49F2-AFD9-571970DBF54D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1516-3_pn\\/dp_rail_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1C000931-0727-4469-B244-6C7F4242B4A5", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1516-3_pn\\/dp_rail:-:*:*:*:*:*:*:*", "matchCriteriaId": "B48A5D4F-FE8B-46CD-9147-8C9A9EDD8E50", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1516-3_pn\\/dp_tx_rail_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "74A1DC89-11D6-41BB-9DE0-872F7CDB786F", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1516-3_pn\\/dp_tx_rail:-:*:*:*:*:*:*:*", "matchCriteriaId": "235BD52A-8AE0-45BF-A617-55513DCB4A69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1516f-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B8264FF-DF97-4FE2-A506-4865324C93B1", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1516f-3_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "38837579-43EF-4A35-AFB7-D3F18609F9DB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1516f-3_pn\\/dp_rail_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2CA378DC-3580-446F-95AD-EE6C565E0B3B", "versionEndExcluding": "2.9.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1516f-3_pn\\/dp_rail:-:*:*:*:*:*:*:*", "matchCriteriaId": "E38025C4-697B-4DB8-8363-76DF42652F22", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1517h-3_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9CC16EB7-BC7F-4474-92CE-57C34C0913B8", "versionEndExcluding": "3.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1517h-3_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "ADD49038-EB06-483B-82D8-4479E964D0CF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1518-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "316C2BE4-9194-4103-A656-AE1C35D6E3BB", "versionEndExcluding": "3.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1518-4_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "C325E4B8-3CCF-479B-BE23-C48EC97AB2A9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1518-4_pn\\/dp_mfp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F6D93085-4939-4636-9F30-62DE014E0820", "versionEndExcluding": "3.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1518-4_pn\\/dp_mfp:-:*:*:*:*:*:*:*", "matchCriteriaId": "E2F63E0A-126D-4A93-8159-45EB5E606F81", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1518f-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "435B674A-EF1E-484C-A3C1-1D4A9FF0E4BF", "versionEndExcluding": "3.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1518f-4_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "21873512-ADEC-4147-9EAE-D0DABB949F92", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_s7-1500_cpu_1518hf-4_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DE5D954-D6C3-4370-80EC-82E4FE1ECC30", "versionEndExcluding": "3.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_s7-1500_cpu_1518hf-4_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "552A1FC5-7AA4-4E0B-A60E-BB4FC6D03FA7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation.\r\n\r\nThis could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate." }, { "lang": "es", "value": "Las implementaciones de OPC UA (ANSI C y C++) en los productos afectados contienen una vulnerabilidad de desbordamiento de enteros que podr\u00eda provocar que la aplicaci\u00f3n se ejecute en un bucle infinito durante la validaci\u00f3n del certificado. Esto podr\u00eda permitir que un atacante remoto no autenticado cree una condici\u00f3n de denegaci\u00f3n de servicio enviando un certificado especialmente manipulado." } ], "id": "CVE-2023-28831", "lastModified": "2024-11-21T07:56:06.617", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Secondary" } ] }, "published": "2023-09-12T10:15:27.230", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-118850.html" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-711309.html" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-118850.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-711309.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-118850.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-711309.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-118850.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-711309.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-190" } ], "source": "productcert@siemens.com", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2021-08-10 11:15
Modified
2024-11-21 06:14
Severity ?
Summary
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. The vulnerability does not occur when TIA Portal V13 SP1 or any later version was used to provision the device.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf | Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_s7-1200_cpu_firmware | 4.5.0 | |
siemens | cpu_1211c | - | |
siemens | cpu_1212c | - | |
siemens | cpu_1212fc | - | |
siemens | cpu_1214c | - | |
siemens | cpu_1214fc | - | |
siemens | cpu_1215c | - | |
siemens | cpu_1215fc | - | |
siemens | cpu_1217c | - | |
siemens | simatic_step_7_\(tia_portal\) | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_firmware:4.5.0:*:*:*:*:*:*:*", "matchCriteriaId": "F6394ED6-C200-4673-882B-7FC2A4C89C42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:cpu_1211c:-:*:*:*:*:*:*:*", "matchCriteriaId": "172D341B-D863-4C24-9B6E-633EBE87C8C9", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:cpu_1212c:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B475E4F-EE4F-4435-9F0B-8E4FA35377BE", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:cpu_1212fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "1402D624-5AF3-4E25-A2B0-9D9F214EE8FE", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:cpu_1214c:-:*:*:*:*:*:*:*", "matchCriteriaId": "1F714315-8BEB-4BD3-BE59-C6649A0A105E", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:cpu_1214fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "2A988C9F-60DF-4BC5-A890-F03F445DD9BD", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:cpu_1215c:-:*:*:*:*:*:*:*", "matchCriteriaId": "C90820D3-3F3E-4DC4-9DCE-A498CC26268D", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:cpu_1215fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "BAF22AB6-6DAA-4983-99DB-4F2A2E76856F", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:cpu_1217c:-:*:*:*:*:*:*:*", "matchCriteriaId": "4C95F12D-563A-4915-9F26-A461EB4F8FA1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):*:*:*:*:*:*:*:*", "matchCriteriaId": "8EA4509B-FC68-42FC-9CB6-ED3C3E65E153", "versionEndIncluding": "13.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. The vulnerability does not occur when TIA Portal V13 SP1 or any later version was used to provision the device." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en la familia de CPUs SIMATIC S7-1200 (Incluyendo las variantes SIPLUS) (V4.5.0). Los dispositivos afectados no se autentican con las contrase\u00f1as configuradas cuando se aprovisionan con TIA Portal V13. Esto podr\u00eda permitir a un atacante que utilice TIA Portal V13 o versiones posteriores eludir la autenticaci\u00f3n y descargar programas arbitrarios en el PLC. La vulnerabilidad no se produce cuando se utiliza TIA Portal V13 SP1 o cualquier versi\u00f3n posterior para aprovisionar el dispositivo" } ], "id": "CVE-2021-37172", "lastModified": "2024-11-21T06:14:47.323", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-08-10T11:15:09.280", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
cve-2019-10936
Vulnerability from cvelistv5
Published
2019-10-10 00:00
Modified
2024-08-04 22:40
Severity ?
EPSS score ?
Summary
Affected devices improperly handle large amounts of specially crafted UDP packets.
This could allow an unauthenticated remote attacker to trigger a denial of service condition.
References
Impacted products
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "dk_standard_ethernet_controller_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:ek-ertec_200_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ek-ertec_200_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:ek-ertec_200p_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ek-ertec_200p_firmware", "vendor": "siemens", "versions": [ { "lessThan": "4.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cfu_pa", "vendor": "siemens", "versions": [ { "lessThan": "v1.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et200ecopn_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et200ecopn_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et200s_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et200s_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200al_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200al_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200m_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200m_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200mp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200mp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v4.3.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200pro_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200pro_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200s_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200s_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200sp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200sp_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_hmi_comfort_outdoor_panels", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0", "vendor": "siemens", "versions": [ { "lessThan": "v4.2.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_profinet_driver", "vendor": "siemens", "versions": [ { "lessThan": "v2.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_314_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_315-2_dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_315f-2_dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_315f-2_dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_317-2_dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_pn\\/dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_317-2_pn\\/dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_319-3_pn\\/dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_319-3_pn\\/dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2_pn:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_cpu_412-2_pn", "vendor": "siemens", "versions": [ { "lessThan": "v7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\\/dp:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_cpu_414-3_pn\\/dp", "vendor": "siemens", "versions": [ { "lessThan": "v7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\\/dp:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_cpu_416-3_pn\\/dp", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "v7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-400_h_v6_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_h_v6_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "v6.0.9", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v6_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_pn\\/dp_v6_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-410_cpu_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-410_cpu_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v8.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-1200_cpu", "vendor": "siemens", "versions": [ { "lessThan": "v4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-1500_cpu", "vendor": "siemens", "versions": [ { "lessThan": "v2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-1500_controller:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-1500_controller", "vendor": "siemens", "versions": [ { "lessThan": "v2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_tdc_cp51m1_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v1.1.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_tdc_cpu555_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v1.1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:simatic_winac_rtx_2010:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_winac_rtx_2010", "vendor": "siemens", "versions": [ { "lessThan": "v2010_sp3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\)_2010:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_winac_rtx_\\(f\\)_2010", "vendor": "siemens", "versions": [ { "lessThan": "v2010_sp3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_dcm", "vendor": "siemens", "versions": [ { "lessThan": "v1.5_hf1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_dcp", "vendor": "siemens", "versions": [ { "lessThan": "v1.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_g110m", "vendor": "siemens", "versions": [ { "lessThan": "v4.7_sp10_hf5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_g120", "vendor": "siemens", "versions": [ { "lessThan": "v4.7_sp10_hf5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_g130", "vendor": "siemens", "versions": [ { "lessThan": "v4.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_g150", "vendor": "siemens", "versions": [ { "lessThan": "v4.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_gh150", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_gl150", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_gm150", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_s110", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_s120", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_sl150", "vendor": "siemens", "versions": [ { "lessThan": "v4.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_sl150", "vendor": "siemens", "versions": [ { "lessThan": "v4.7_hf33", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_sm120", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinumerik_828d", "vendor": "siemens", "versions": [ { "lessThan": "v4.8_sp5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinumerik_840d_sl", "vendor": "siemens", "versions": [ { "lessThan": "v4.8_sp6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:siplus_s7-300_cpu_314:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "siplus_s7-300_cpu_314", "vendor": "siemens", "versions": [ { "lessThan": "v3.3.17", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2019-10936", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-09T14:36:59.481395Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-09T15:59:12.602Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-04T22:40:15.253Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.6 Patch 01" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU PA", "vendor": "Siemens", "versions": [ { "lessThan": "V1.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200M (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-3 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-4 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/2 HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/3 HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN: IO-Link Master", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200S (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Outdoor Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI KTP Mobile Panels", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PROFINET Driver", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 412-2 PN V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.9", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2.2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.5 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M V4.7 PN Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP10 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP10 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 4.8" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 4.8" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110 Control Unit", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 4.8" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF33" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP5" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP6" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "Affected devices improperly handle large amounts of specially crafted UDP packets.\r\n\r\nThis could allow an unauthenticated remote attacker to trigger a denial of service condition." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-09T12:03:55.957Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-10936", "datePublished": "2019-10-10T00:00:00", "dateReserved": "2019-04-08T00:00:00", "dateUpdated": "2024-08-04T22:40:15.253Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-37172
Vulnerability from cvelistv5
Published
2021-08-10 10:35
Modified
2024-08-04 01:16
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. The vulnerability does not occur when TIA Portal V13 SP1 or any later version was used to provision the device.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens | SIMATIC S7-1200 CPU family (incl. SIPLUS variants) |
Version: V4.5.0 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T01:16:03.220Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V4.5.0" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. The vulnerability does not occur when TIA Portal V13 SP1 or any later version was used to provision the device." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-287", "description": "CWE-287: Improper Authentication", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-09-14T10:47:40", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-37172", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "V4.5.0" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. The vulnerability does not occur when TIA Portal V13 SP1 or any later version was used to provision the device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-287: Improper Authentication" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-37172", "datePublished": "2021-08-10T10:35:34", "dateReserved": "2021-07-21T00:00:00", "dateUpdated": "2024-08-04T01:16:03.220Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-28831
Vulnerability from cvelistv5
Published
2023-09-12 09:32
Modified
2025-01-14 10:27
Severity ?
EPSS score ?
Summary
The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation.
This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC BRAUMAT |
Version: 0 < V8.1 SP1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T13:51:38.545Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-711309.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-118850.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-711309.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-118850.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC BRAUMAT", "vendor": "Siemens", "versions": [ { "lessThan": "V8.1 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Cloud Connect 7 CC712", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Cloud Connect 7 CC716", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Comfort/Mobile RT", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Drive Controller CPU 1504D TF", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Drive Controller CPU 1504D TF", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "V3.0.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Drive Controller CPU 1507D TF", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Drive Controller CPU 1507D TF", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "V3.0.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V21.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V30.1.0", "status": "affected", "version": "V30.0.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagMonitor", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V14", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V16", "vendor": "Siemens", "versions": [ { "lessThan": "V16 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 SP1 Update 1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS neo V4.0", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1510SP F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1510SP F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1510SP-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1510SP-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511C-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511C-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511T-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511T-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511TF-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511TF-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1512C-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1512C-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1512SP F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1512SP F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1512SP-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1512SP-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1513F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1513F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1513F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1514SP F-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1514SP-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1514SPT F-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1514SPT-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515F-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515F-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515F-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515T-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515T-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515TF-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515TF-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1517-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller V2", "vendor": "Siemens", "versions": [ { "lessThan": "V21.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller V3", "vendor": "Siemens", "versions": [ { "lessThan": "V30.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-PLCSIM Advanced", "vendor": "Siemens", "versions": [ { "lessThan": "V5.0 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC SISTAR", "vendor": "Siemens", "versions": [ { "lessThan": "V8.1 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OA V3.17", "vendor": "Siemens", "versions": [ { "lessThan": "V3.17 P029", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OA V3.18", "vendor": "Siemens", "versions": [ { "lessThan": "V3.18 P019", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OA V3.19", "vendor": "Siemens", "versions": [ { "lessThan": "V3.19 P005", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OPC UA Client", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V17", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V18", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Unified OPC UA Server", "vendor": "Siemens", "versions": [ { "lessThan": "V5.0.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V8.0", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0 Update 5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK MC", "vendor": "Siemens", "versions": [ { "lessThan": "V1.22", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK ONE", "vendor": "Siemens", "versions": [ { "lessThan": "V6.22", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1510SP-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1510SP-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1515F-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1515F-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation.\r\n\r\nThis could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-190", "description": "CWE-190: Integer Overflow or Wraparound", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-14T10:27:15.947Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-711309.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-118850.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-711309.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-118850.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-28831", "datePublished": "2023-09-12T09:32:06.153Z", "dateReserved": "2023-03-24T15:17:33.934Z", "dateUpdated": "2025-01-14T10:27:15.947Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }