CVE-2021-37172 (GCVE-0-2021-37172)

Vulnerability from cvelistv5 – Published: 2021-08-10 10:35 – Updated: 2024-08-04 01:16
VLAI?
Summary
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. The vulnerability does not occur when TIA Portal V13 SP1 or any later version was used to provision the device.
Severity ?
No CVSS data available.
CWE
  • CWE-287 - Improper Authentication
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:16:03.220Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "V4.5.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. The vulnerability does not occur when TIA Portal V13 SP1 or any later version was used to provision the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287: Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-14T10:47:40",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-37172",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V4.5.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. The vulnerability does not occur when TIA Portal V13 SP1 or any later version was used to provision the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287: Improper Authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-37172",
    "datePublished": "2021-08-10T10:35:34",
    "dateReserved": "2021-07-21T00:00:00",
    "dateUpdated": "2024-08-04T01:16:03.220Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_s7-1200_cpu_firmware:4.5.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F6394ED6-C200-4673-882B-7FC2A4C89C42\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:cpu_1211c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"172D341B-D863-4C24-9B6E-633EBE87C8C9\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:cpu_1212c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1B475E4F-EE4F-4435-9F0B-8E4FA35377BE\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:cpu_1212fc:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1402D624-5AF3-4E25-A2B0-9D9F214EE8FE\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:cpu_1214c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1F714315-8BEB-4BD3-BE59-C6649A0A105E\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:cpu_1214fc:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2A988C9F-60DF-4BC5-A890-F03F445DD9BD\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:cpu_1215c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C90820D3-3F3E-4DC4-9DCE-A498CC26268D\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:cpu_1215fc:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"BAF22AB6-6DAA-4983-99DB-4F2A2E76856F\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:cpu_1217c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4C95F12D-563A-4915-9F26-A461EB4F8FA1\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:simatic_step_7_\\\\(tia_portal\\\\):*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"13.0\", \"matchCriteriaId\": \"8EA4509B-FC68-42FC-9CB6-ED3C3E65E153\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. The vulnerability does not occur when TIA Portal V13 SP1 or any later version was used to provision the device.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en la familia de CPUs SIMATIC S7-1200 (Incluyendo las variantes SIPLUS) (V4.5.0). Los dispositivos afectados no se autentican con las contrase\\u00f1as configuradas cuando se aprovisionan con TIA Portal V13. Esto podr\\u00eda permitir a un atacante que utilice TIA Portal V13 o versiones posteriores eludir la autenticaci\\u00f3n y descargar programas arbitrarios en el PLC. La vulnerabilidad no se produce cuando se utiliza TIA Portal V13 SP1 o cualquier versi\\u00f3n posterior para aprovisionar el dispositivo\"}]",
      "id": "CVE-2021-37172",
      "lastModified": "2024-11-21T06:14:47.323",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:P/A:N\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2021-08-10T11:15:09.280",
      "references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-287\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-287\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-37172\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-08-10T11:15:09.280\",\"lastModified\":\"2024-11-21T06:14:47.323\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. The vulnerability does not occur when TIA Portal V13 SP1 or any later version was used to provision the device.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en la familia de CPUs SIMATIC S7-1200 (Incluyendo las variantes SIPLUS) (V4.5.0). Los dispositivos afectados no se autentican con las contrase\u00f1as configuradas cuando se aprovisionan con TIA Portal V13. Esto podr\u00eda permitir a un atacante que utilice TIA Portal V13 o versiones posteriores eludir la autenticaci\u00f3n y descargar programas arbitrarios en el PLC. La vulnerabilidad no se produce cuando se utiliza TIA Portal V13 SP1 o cualquier versi\u00f3n posterior para aprovisionar el dispositivo\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:P/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1200_cpu_firmware:4.5.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F6394ED6-C200-4673-882B-7FC2A4C89C42\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:cpu_1211c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"172D341B-D863-4C24-9B6E-633EBE87C8C9\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:cpu_1212c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1B475E4F-EE4F-4435-9F0B-8E4FA35377BE\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:cpu_1212fc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1402D624-5AF3-4E25-A2B0-9D9F214EE8FE\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:cpu_1214c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1F714315-8BEB-4BD3-BE59-C6649A0A105E\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:cpu_1214fc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2A988C9F-60DF-4BC5-A890-F03F445DD9BD\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:cpu_1215c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C90820D3-3F3E-4DC4-9DCE-A498CC26268D\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:cpu_1215fc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BAF22AB6-6DAA-4983-99DB-4F2A2E76856F\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:cpu_1217c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4C95F12D-563A-4915-9F26-A461EB4F8FA1\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_step_7_\\\\(tia_portal\\\\):*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"13.0\",\"matchCriteriaId\":\"8EA4509B-FC68-42FC-9CB6-ED3C3E65E153\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.