Search criteria

212 vulnerabilities found for simcenter_femap by siemens

CVE-2025-40829 (GCVE-0-2025-40829)

Vulnerability from nvd – Published: 2025-12-12 08:36 – Updated: 2025-12-12 20:26
VLAI?
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2512). The affected applications contains an uninitialized memory vulnerability while parsing specially crafted SLDPRT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-27146)
CWE
  • CWE-908 - Use of Uninitialized Resource
Assigner
Impacted products
Vendor Product Version
Siemens Simcenter Femap Affected: 0 , < V2512 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40829",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-12T20:26:41.769784Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-12T20:26:52.400Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2512",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2512). The affected applications contains an uninitialized memory vulnerability while parsing specially crafted SLDPRT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-27146)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-908",
              "description": "CWE-908: Use of Uninitialized Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-12T08:36:47.219Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-512988.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-40829",
    "datePublished": "2025-12-12T08:36:47.219Z",
    "dateReserved": "2025-04-16T08:50:26.976Z",
    "dateUpdated": "2025-12-12T20:26:52.400Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-40764 (GCVE-0-2025-40764)

Vulnerability from nvd – Published: 2025-08-12 11:17 – Updated: 2025-08-12 15:38
VLAI?
Summary
A vulnerability has been identified in Simcenter Femap V2406 (All versions < V2406.0003), Simcenter Femap V2412 (All versions < V2412.0002). The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
CWE
Assigner
Impacted products
Vendor Product Version
Siemens Simcenter Femap V2406 Affected: 0 , < V2406.0003 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40764",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-12T15:17:36.248992Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-12T15:38:05.698Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap V2406",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2406.0003",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap V2412",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2412.0002",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Simcenter Femap V2406 (All versions \u003c V2406.0003), Simcenter Femap V2412 (All versions \u003c V2412.0002). The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-12T11:17:14.577Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-674084.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-40764",
    "datePublished": "2025-08-12T11:17:14.577Z",
    "dateReserved": "2025-04-16T08:39:30.032Z",
    "dateUpdated": "2025-08-12T15:38:05.698Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-40762 (GCVE-0-2025-40762)

Vulnerability from nvd – Published: 2025-08-12 11:17 – Updated: 2025-08-12 17:58
VLAI?
Summary
A vulnerability has been identified in Simcenter Femap V2406 (All versions < V2406.0003), Simcenter Femap V2412 (All versions < V2412.0002). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted STP file. This could allow an attacker to execute code in the context of the current process.(ZDI-CAN-26692)
CWE
Assigner
Impacted products
Vendor Product Version
Siemens Simcenter Femap V2406 Affected: 0 , < V2406.0003 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40762",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-12T17:56:40.311762Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-12T17:58:09.755Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap V2406",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2406.0003",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap V2412",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2412.0002",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Simcenter Femap V2406 (All versions \u003c V2406.0003), Simcenter Femap V2412 (All versions \u003c V2412.0002). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted STP file. This could allow an attacker to execute code in the context of the current process.(ZDI-CAN-26692)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-12T11:17:13.239Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-674084.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-40762",
    "datePublished": "2025-08-12T11:17:13.239Z",
    "dateReserved": "2025-04-16T08:39:30.032Z",
    "dateUpdated": "2025-08-12T17:58:09.755Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-25175 (GCVE-0-2025-25175)

Vulnerability from nvd – Published: 2025-03-13 09:07 – Updated: 2025-03-13 19:38
VLAI?
Summary
A vulnerability has been identified in Simcenter Femap V2401 (All versions < V2401.0003), Simcenter Femap V2406 (All versions < V2406.0002). The affected application contains a memory corruption vulnerability while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25443)
CWE
  • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
Impacted products
Vendor Product Version
Siemens Simcenter Femap V2401 Affected: 0 , < V2401.0003 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-25175",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-13T19:38:17.539333Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-13T19:38:24.491Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap V2401",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2401.0003",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap V2406",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2406.0002",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Simcenter Femap V2401 (All versions \u003c V2401.0003), Simcenter Femap V2406 (All versions \u003c V2406.0002). The affected application contains a memory corruption vulnerability while  parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25443)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-13T09:07:09.436Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-920092.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-25175",
    "datePublished": "2025-03-13T09:07:09.436Z",
    "dateReserved": "2025-02-03T13:50:58.888Z",
    "dateUpdated": "2025-03-13T19:38:24.491Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-33654 (GCVE-0-2024-33654)

Vulnerability from nvd – Published: 2024-07-09 12:05 – Updated: 2024-08-02 02:36
VLAI?
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
CWE
Assigner
Impacted products
Vendor Product Version
Siemens Simcenter Femap Affected: 0 , < V2406 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simcenter_femap",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2406",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-33654",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-09T14:10:16.748309Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-09T14:12:29.920Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T02:36:04.512Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2406",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-09T12:05:03.457Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-33654",
    "datePublished": "2024-07-09T12:05:03.457Z",
    "dateReserved": "2024-04-25T09:55:59.242Z",
    "dateUpdated": "2024-08-02T02:36:04.512Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-33653 (GCVE-0-2024-33653)

Vulnerability from nvd – Published: 2024-07-09 12:05 – Updated: 2024-08-02 02:36
VLAI?
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
CWE
Assigner
Impacted products
Vendor Product Version
Siemens Simcenter Femap Affected: 0 , < V2406 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simcenter_femap",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2406",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-33653",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-09T13:24:41.569853Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-09T13:35:51.112Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T02:36:04.550Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2406",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-09T12:05:02.168Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-33653",
    "datePublished": "2024-07-09T12:05:02.168Z",
    "dateReserved": "2024-04-25T09:55:59.241Z",
    "dateUpdated": "2024-08-02T02:36:04.550Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-32056 (GCVE-0-2024-32056)

Vulnerability from nvd – Published: 2024-07-09 12:04 – Updated: 2025-08-27 20:42
VLAI?
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted IGS part file. This could allow an attacker to execute code in the context of the current process.
CWE
Assigner
Impacted products
Vendor Product Version
Siemens Simcenter Femap Affected: 0 , < V2406 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:simcenter_femap:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simcenter_femap",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2406",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-32056",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-23T13:54:13.288247Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-27T20:42:54.119Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T02:06:44.013Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2406",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted IGS part file. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-09T12:04:46.565Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-32056",
    "datePublished": "2024-07-09T12:04:46.565Z",
    "dateReserved": "2024-04-10T10:05:05.704Z",
    "dateUpdated": "2025-08-27T20:42:54.119Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-40829 (GCVE-0-2025-40829)

Vulnerability from cvelistv5 – Published: 2025-12-12 08:36 – Updated: 2025-12-12 20:26
VLAI?
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2512). The affected applications contains an uninitialized memory vulnerability while parsing specially crafted SLDPRT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-27146)
CWE
  • CWE-908 - Use of Uninitialized Resource
Assigner
Impacted products
Vendor Product Version
Siemens Simcenter Femap Affected: 0 , < V2512 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40829",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-12T20:26:41.769784Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-12T20:26:52.400Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2512",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2512). The affected applications contains an uninitialized memory vulnerability while parsing specially crafted SLDPRT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-27146)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-908",
              "description": "CWE-908: Use of Uninitialized Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-12T08:36:47.219Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-512988.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-40829",
    "datePublished": "2025-12-12T08:36:47.219Z",
    "dateReserved": "2025-04-16T08:50:26.976Z",
    "dateUpdated": "2025-12-12T20:26:52.400Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-40764 (GCVE-0-2025-40764)

Vulnerability from cvelistv5 – Published: 2025-08-12 11:17 – Updated: 2025-08-12 15:38
VLAI?
Summary
A vulnerability has been identified in Simcenter Femap V2406 (All versions < V2406.0003), Simcenter Femap V2412 (All versions < V2412.0002). The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
CWE
Assigner
Impacted products
Vendor Product Version
Siemens Simcenter Femap V2406 Affected: 0 , < V2406.0003 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40764",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-12T15:17:36.248992Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-12T15:38:05.698Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap V2406",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2406.0003",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap V2412",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2412.0002",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Simcenter Femap V2406 (All versions \u003c V2406.0003), Simcenter Femap V2412 (All versions \u003c V2412.0002). The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-12T11:17:14.577Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-674084.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-40764",
    "datePublished": "2025-08-12T11:17:14.577Z",
    "dateReserved": "2025-04-16T08:39:30.032Z",
    "dateUpdated": "2025-08-12T15:38:05.698Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-40762 (GCVE-0-2025-40762)

Vulnerability from cvelistv5 – Published: 2025-08-12 11:17 – Updated: 2025-08-12 17:58
VLAI?
Summary
A vulnerability has been identified in Simcenter Femap V2406 (All versions < V2406.0003), Simcenter Femap V2412 (All versions < V2412.0002). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted STP file. This could allow an attacker to execute code in the context of the current process.(ZDI-CAN-26692)
CWE
Assigner
Impacted products
Vendor Product Version
Siemens Simcenter Femap V2406 Affected: 0 , < V2406.0003 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40762",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-12T17:56:40.311762Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-12T17:58:09.755Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap V2406",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2406.0003",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap V2412",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2412.0002",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Simcenter Femap V2406 (All versions \u003c V2406.0003), Simcenter Femap V2412 (All versions \u003c V2412.0002). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted STP file. This could allow an attacker to execute code in the context of the current process.(ZDI-CAN-26692)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-12T11:17:13.239Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-674084.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-40762",
    "datePublished": "2025-08-12T11:17:13.239Z",
    "dateReserved": "2025-04-16T08:39:30.032Z",
    "dateUpdated": "2025-08-12T17:58:09.755Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-25175 (GCVE-0-2025-25175)

Vulnerability from cvelistv5 – Published: 2025-03-13 09:07 – Updated: 2025-03-13 19:38
VLAI?
Summary
A vulnerability has been identified in Simcenter Femap V2401 (All versions < V2401.0003), Simcenter Femap V2406 (All versions < V2406.0002). The affected application contains a memory corruption vulnerability while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25443)
CWE
  • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
Impacted products
Vendor Product Version
Siemens Simcenter Femap V2401 Affected: 0 , < V2401.0003 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-25175",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-13T19:38:17.539333Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-13T19:38:24.491Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap V2401",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2401.0003",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap V2406",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2406.0002",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Simcenter Femap V2401 (All versions \u003c V2401.0003), Simcenter Femap V2406 (All versions \u003c V2406.0002). The affected application contains a memory corruption vulnerability while  parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25443)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-13T09:07:09.436Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-920092.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-25175",
    "datePublished": "2025-03-13T09:07:09.436Z",
    "dateReserved": "2025-02-03T13:50:58.888Z",
    "dateUpdated": "2025-03-13T19:38:24.491Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-33654 (GCVE-0-2024-33654)

Vulnerability from cvelistv5 – Published: 2024-07-09 12:05 – Updated: 2024-08-02 02:36
VLAI?
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
CWE
Assigner
Impacted products
Vendor Product Version
Siemens Simcenter Femap Affected: 0 , < V2406 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simcenter_femap",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2406",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-33654",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-09T14:10:16.748309Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-09T14:12:29.920Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T02:36:04.512Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2406",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-09T12:05:03.457Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-33654",
    "datePublished": "2024-07-09T12:05:03.457Z",
    "dateReserved": "2024-04-25T09:55:59.242Z",
    "dateUpdated": "2024-08-02T02:36:04.512Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-33653 (GCVE-0-2024-33653)

Vulnerability from cvelistv5 – Published: 2024-07-09 12:05 – Updated: 2024-08-02 02:36
VLAI?
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
CWE
Assigner
Impacted products
Vendor Product Version
Siemens Simcenter Femap Affected: 0 , < V2406 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simcenter_femap",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2406",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-33653",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-09T13:24:41.569853Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-09T13:35:51.112Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T02:36:04.550Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2406",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-09T12:05:02.168Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-33653",
    "datePublished": "2024-07-09T12:05:02.168Z",
    "dateReserved": "2024-04-25T09:55:59.241Z",
    "dateUpdated": "2024-08-02T02:36:04.550Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-32056 (GCVE-0-2024-32056)

Vulnerability from cvelistv5 – Published: 2024-07-09 12:04 – Updated: 2025-08-27 20:42
VLAI?
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted IGS part file. This could allow an attacker to execute code in the context of the current process.
CWE
Assigner
Impacted products
Vendor Product Version
Siemens Simcenter Femap Affected: 0 , < V2406 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:simcenter_femap:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simcenter_femap",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2406",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-32056",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-23T13:54:13.288247Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-27T20:42:54.119Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T02:06:44.013Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Simcenter Femap",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2406",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted IGS part file. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-09T12:04:46.565Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-32056",
    "datePublished": "2024-07-09T12:04:46.565Z",
    "dateReserved": "2024-04-10T10:05:05.704Z",
    "dateUpdated": "2025-08-27T20:42:54.119Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

FKIE_CVE-2025-40762

Vulnerability from fkie_nvd - Published: 2025-08-12 12:15 - Updated: 2025-08-20 16:20
Summary
A vulnerability has been identified in Simcenter Femap V2406 (All versions < V2406.0003), Simcenter Femap V2412 (All versions < V2412.0002). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted STP file. This could allow an attacker to execute code in the context of the current process.(ZDI-CAN-26692)
Impacted products
Vendor Product Version
siemens simcenter_femap *
siemens simcenter_femap *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B6246AB-93A6-42E8-8400-339F3C3D893C",
              "versionEndExcluding": "2406.0003",
              "versionStartIncluding": "2406.0000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0D3DE6A-FADD-4273-8870-695A23917A3F",
              "versionEndExcluding": "2412.0002",
              "versionStartIncluding": "2412.0000",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Simcenter Femap V2406 (All versions \u003c V2406.0003), Simcenter Femap V2412 (All versions \u003c V2412.0002). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted STP file. This could allow an attacker to execute code in the context of the current process.(ZDI-CAN-26692)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Simcenter Femap V2406 (todas las versiones anteriores a V2406.0003) y Simcenter Femap V2412 (todas las versiones anteriores a V2412.0002). Las aplicaciones afectadas presentan una vulnerabilidad de escritura fuera de los l\u00edmites al analizar un archivo STP especialmente manipulado. Esto podr\u00eda permitir que un atacante ejecute c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-26692)"
    }
  ],
  "id": "CVE-2025-40762",
  "lastModified": "2025-08-20T16:20:50.253",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-08-12T12:15:37.047",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-674084.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2025-40764

Vulnerability from fkie_nvd - Published: 2025-08-12 12:15 - Updated: 2025-08-20 16:20
Summary
A vulnerability has been identified in Simcenter Femap V2406 (All versions < V2406.0003), Simcenter Femap V2412 (All versions < V2412.0002). The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
Impacted products
Vendor Product Version
siemens simcenter_femap *
siemens simcenter_femap *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B6246AB-93A6-42E8-8400-339F3C3D893C",
              "versionEndExcluding": "2406.0003",
              "versionStartIncluding": "2406.0000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0D3DE6A-FADD-4273-8870-695A23917A3F",
              "versionEndExcluding": "2412.0002",
              "versionStartIncluding": "2412.0000",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Simcenter Femap V2406 (All versions \u003c V2406.0003), Simcenter Femap V2412 (All versions \u003c V2412.0002). The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Simcenter Femap V2406 (todas las versiones anteriores a V2406.0003) y Simcenter Femap V2412 (todas las versiones anteriores a V2412.0002). Las aplicaciones afectadas presentan una vulnerabilidad de lectura fuera de los l\u00edmites al analizar archivos BMP especialmente manipulados. Esto podr\u00eda permitir que un atacante ejecute c\u00f3digo en el contexto del proceso actual."
    }
  ],
  "id": "CVE-2025-40764",
  "lastModified": "2025-08-20T16:20:52.210",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-08-12T12:15:37.220",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-674084.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2025-25175

Vulnerability from fkie_nvd - Published: 2025-03-13 09:15 - Updated: 2025-08-19 17:36
Summary
A vulnerability has been identified in Simcenter Femap V2401 (All versions < V2401.0003), Simcenter Femap V2406 (All versions < V2406.0002). The affected application contains a memory corruption vulnerability while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25443)
Impacted products
Vendor Product Version
siemens simcenter_femap *
siemens simcenter_femap *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "50DEC5C8-2780-4172-94FE-605F35A72E2E",
              "versionEndExcluding": "2401.0003",
              "versionStartIncluding": "2401.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1F82CC6-5557-49BF-9F05-D47C9748C458",
              "versionEndExcluding": "2406.0002",
              "versionStartIncluding": "2406.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Simcenter Femap V2401 (All versions \u003c V2401.0003), Simcenter Femap V2406 (All versions \u003c V2406.0002). The affected application contains a memory corruption vulnerability while  parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25443)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Simcenter Femap V2401 (todas las versiones anteriores a V2401.0003) y Simcenter Femap V2406 (todas las versiones anteriores a V2406.0002). La aplicaci\u00f3n afectada presenta una vulnerabilidad de corrupci\u00f3n de memoria al analizar archivos .NEU especialmente manipulados. Esto podr\u00eda permitir que un atacante ejecute c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-25443)"
    }
  ],
  "id": "CVE-2025-25175",
  "lastModified": "2025-08-19T17:36:25.510",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-03-13T09:15:14.123",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-920092.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2024-33653

Vulnerability from fkie_nvd - Published: 2024-07-09 12:15 - Updated: 2024-11-21 09:17
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
Impacted products
Vendor Product Version
siemens simcenter_femap *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0696F6FD-A974-4533-BF83-DA6A02501D0C",
              "versionEndExcluding": "2406.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Simcenter Femap (Todas las versiones \u0026lt; V2406). Las aplicaciones afectadas contienen una lectura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada mientras analizan archivos BMP especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual."
    }
  ],
  "id": "CVE-2024-33653",
  "lastModified": "2024-11-21T09:17:19.660",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-07-09T12:15:13.553",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2024-33654

Vulnerability from fkie_nvd - Published: 2024-07-09 12:15 - Updated: 2024-11-21 09:17
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
Impacted products
Vendor Product Version
siemens simcenter_femap *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0696F6FD-A974-4533-BF83-DA6A02501D0C",
              "versionEndExcluding": "2406.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Simcenter Femap (Todas las versiones \u0026lt; V2406). Las aplicaciones afectadas contienen una lectura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada mientras analizan archivos BMP especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual."
    }
  ],
  "id": "CVE-2024-33654",
  "lastModified": "2024-11-21T09:17:19.813",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-07-09T12:15:13.773",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2024-32056

Vulnerability from fkie_nvd - Published: 2024-07-09 12:15 - Updated: 2024-11-21 09:14
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted IGS part file. This could allow an attacker to execute code in the context of the current process.
Impacted products
Vendor Product Version
siemens simcenter_femap *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0696F6FD-A974-4533-BF83-DA6A02501D0C",
              "versionEndExcluding": "2406.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted IGS part file. This could allow an attacker to execute code in the context of the current process."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Simcenter Femap (Todas las versiones \u0026lt; V2406). La aplicaci\u00f3n afectada contiene una escritura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de un b\u00fafer asignado mientras analiza un archivo de pieza IGS especialmente manipulado. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual."
    }
  ],
  "id": "CVE-2024-32056",
  "lastModified": "2024-11-21T09:14:23.930",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-07-09T12:15:12.097",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2024-33577

Vulnerability from fkie_nvd - Published: 2024-05-14 16:17 - Updated: 2025-10-03 20:37
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain a stack overflow vulnerability while parsing specially strings as argument for one of the application binaries. This could allow an attacker to execute code in the context of the current process.
Impacted products
Vendor Product Version
siemens simcenter_femap *
siemens simcenter_nastran *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "539884E0-2611-44BD-A4DF-B4A6761EA085",
              "versionEndExcluding": "2406.0000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_nastran:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5CD5915A-B1D8-4371-95FB-F0A002712225",
              "versionEndExcluding": "2406.90",
              "versionStartIncluding": "2306.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected applications contain a stack overflow vulnerability while parsing specially strings as argument for one of the application binaries. This could allow an attacker to execute code in the context of the current process."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Simcenter Nastran 2306 (Todas las versiones), Simcenter Nastran 2312 (Todas las versiones), Simcenter Nastran 2406 (Todas las versiones \u0026lt; V2406.90). Las aplicaciones afectadas contienen una vulnerabilidad de desbordamiento de pila al analizar cadenas especiales como argumento para uno de los archivos binarios de la aplicaci\u00f3n. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual."
    }
  ],
  "id": "CVE-2024-33577",
  "lastModified": "2025-10-03T20:37:49.900",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-05-14T16:17:20.707",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-258494.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-258494.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2024-32066

Vulnerability from fkie_nvd - Published: 2024-05-14 16:17 - Updated: 2025-08-20 16:24
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21578)
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:ps\\/iges_parasolid_translator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86C34CAC-4700-4BAD-80DB-634DC7FD38AF",
              "versionEndExcluding": "27.1.215",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "539884E0-2611-44BD-A4DF-B4A6761EA085",
              "versionEndExcluding": "2406.0000",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21578)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en el componente PS/IGES Parasolid Translator (todas las versiones "
    }
  ],
  "id": "CVE-2024-32066",
  "lastModified": "2025-08-20T16:24:21.860",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-05-14T16:17:01.513",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-976324.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-976324.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2024-32065

Vulnerability from fkie_nvd - Published: 2024-05-14 16:17 - Updated: 2025-08-20 16:24
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21577)
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:ps\\/iges_parasolid_translator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86C34CAC-4700-4BAD-80DB-634DC7FD38AF",
              "versionEndExcluding": "27.1.215",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "539884E0-2611-44BD-A4DF-B4A6761EA085",
              "versionEndExcluding": "2406.0000",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21577)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en el componente PS/IGES Parasolid Translator (todas las versiones "
    }
  ],
  "id": "CVE-2024-32065",
  "lastModified": "2025-08-20T16:24:55.993",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-05-14T16:17:01.120",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-976324.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-976324.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2024-32064

Vulnerability from fkie_nvd - Published: 2024-05-14 16:17 - Updated: 2025-08-20 16:25
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21575)
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:ps\\/iges_parasolid_translator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86C34CAC-4700-4BAD-80DB-634DC7FD38AF",
              "versionEndExcluding": "27.1.215",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "539884E0-2611-44BD-A4DF-B4A6761EA085",
              "versionEndExcluding": "2406.0000",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21575)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en el componente PS/IGES Parasolid Translator (todas las versiones "
    }
  ],
  "id": "CVE-2024-32064",
  "lastModified": "2025-08-20T16:25:31.760",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-05-14T16:17:00.547",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-976324.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-976324.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2024-32062

Vulnerability from fkie_nvd - Published: 2024-05-14 16:16 - Updated: 2025-08-20 16:25
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected application contains a type confusion vulnerability while parsing IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21568)
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:ps\\/iges_parasolid_translator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86C34CAC-4700-4BAD-80DB-634DC7FD38AF",
              "versionEndExcluding": "27.1.215",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "539884E0-2611-44BD-A4DF-B4A6761EA085",
              "versionEndExcluding": "2406.0000",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected application contains a type confusion vulnerability while parsing IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21568)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en el componente PS/IGES Parasolid Translator (todas las versiones "
    }
  ],
  "id": "CVE-2024-32062",
  "lastModified": "2025-08-20T16:25:37.083",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-05-14T16:16:59.540",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-976324.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-976324.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-843"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2024-32063

Vulnerability from fkie_nvd - Published: 2024-05-14 16:16 - Updated: 2025-08-20 16:25
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected application contains a type confusion vulnerability while parsing IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21573)
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:ps\\/iges_parasolid_translator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86C34CAC-4700-4BAD-80DB-634DC7FD38AF",
              "versionEndExcluding": "27.1.215",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "539884E0-2611-44BD-A4DF-B4A6761EA085",
              "versionEndExcluding": "2406.0000",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected application contains a type confusion vulnerability while parsing IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21573)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en el componente PS/IGES Parasolid Translator (todas las versiones "
    }
  ],
  "id": "CVE-2024-32063",
  "lastModified": "2025-08-20T16:25:34.780",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-05-14T16:16:59.993",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-976324.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-976324.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-843"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2024-32061

Vulnerability from fkie_nvd - Published: 2024-05-14 16:16 - Updated: 2025-08-20 16:26
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21566)
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:ps\\/iges_parasolid_translator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86C34CAC-4700-4BAD-80DB-634DC7FD38AF",
              "versionEndExcluding": "27.1.215",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "539884E0-2611-44BD-A4DF-B4A6761EA085",
              "versionEndExcluding": "2406.0000",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21566)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en el componente PS/IGES Parasolid Translator (todas las versiones "
    }
  ],
  "id": "CVE-2024-32061",
  "lastModified": "2025-08-20T16:26:05.803",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-05-14T16:16:58.980",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-976324.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-976324.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2024-32060

Vulnerability from fkie_nvd - Published: 2024-05-14 16:16 - Updated: 2025-08-20 16:26
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21565)
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:ps\\/iges_parasolid_translator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86C34CAC-4700-4BAD-80DB-634DC7FD38AF",
              "versionEndExcluding": "27.1.215",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "539884E0-2611-44BD-A4DF-B4A6761EA085",
              "versionEndExcluding": "2406.0000",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21565)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en el componente PS/IGES Parasolid Translator (todas las versiones "
    }
  ],
  "id": "CVE-2024-32060",
  "lastModified": "2025-08-20T16:26:30.260",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-05-14T16:16:58.280",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-976324.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-976324.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2024-32059

Vulnerability from fkie_nvd - Published: 2024-05-14 16:16 - Updated: 2025-08-20 16:26
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21564)
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:ps\\/iges_parasolid_translator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86C34CAC-4700-4BAD-80DB-634DC7FD38AF",
              "versionEndExcluding": "27.1.215",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "539884E0-2611-44BD-A4DF-B4A6761EA085",
              "versionEndExcluding": "2406.0000",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21564)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en el componente PS/IGES Parasolid Translator (todas las versiones "
    }
  ],
  "id": "CVE-2024-32059",
  "lastModified": "2025-08-20T16:26:25.397",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-05-14T16:16:57.627",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-976324.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-976324.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2024-32058

Vulnerability from fkie_nvd - Published: 2024-05-14 16:16 - Updated: 2025-08-20 16:26
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected application is vulnerable to memory corruption while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21563)
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:ps\\/iges_parasolid_translator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86C34CAC-4700-4BAD-80DB-634DC7FD38AF",
              "versionEndExcluding": "27.1.215",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "539884E0-2611-44BD-A4DF-B4A6761EA085",
              "versionEndExcluding": "2406.0000",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected application is vulnerable to memory corruption while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21563)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en el componente PS/IGES Parasolid Translator (todas las versiones "
    }
  ],
  "id": "CVE-2024-32058",
  "lastModified": "2025-08-20T16:26:45.627",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-05-14T16:16:56.907",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-976324.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-976324.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    }
  ]
}