All the vulnerabilites related to siemens - sinamics_g110
Vulnerability from fkie_nvd
Published
2013-12-07 00:55
Modified
2024-11-21 01:59
Severity ?
Summary
Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | sinamics_s\/g_family_firmware | * | |
siemens | sinamics_g110 | - | |
siemens | sinamics_g110d | - | |
siemens | sinamics_g120 | - | |
siemens | sinamics_g120c | - | |
siemens | sinamics_g120d | - | |
siemens | sinamics_g120p | - | |
siemens | sinamics_g130 | - | |
siemens | sinamics_g150 | - | |
siemens | sinamics_g180 | - | |
siemens | sinamics_s110 | - | |
siemens | sinamics_s120 | - | |
siemens | sinamics_s120cm | - | |
siemens | sinamics_s150 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s\\/g_family_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F15BC1E1-45E3-44F0-BD41-E7A73FB33662", "versionEndIncluding": "4.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g110:-:*:*:*:*:*:*:*", "matchCriteriaId": "E5ADF0BB-01FA-4FE4-BF4D-D33A6C5DAAFD", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:sinamics_g110d:-:*:*:*:*:*:*:*", "matchCriteriaId": "5CE4257F-7262-4CC0-A874-374106B4B2C8", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*", "matchCriteriaId": "61A60DCE-384B-43A4-A669-973FB8ECA932", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:sinamics_g120c:-:*:*:*:*:*:*:*", "matchCriteriaId": "909DED2E-4CA6-4A07-B924-797260FDE2E4", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:sinamics_g120d:-:*:*:*:*:*:*:*", "matchCriteriaId": "75ED7DEA-67F8-4971-A076-79AF82026FD0", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:sinamics_g120p:-:*:*:*:*:*:*:*", "matchCriteriaId": "21FAA04F-FBE9-4EFA-BE79-1EAFF47A20D3", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*", "matchCriteriaId": "373DBE44-AC28-4D04-93BB-35CD8C60E899", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2296CA65-0E89-4BCB-8003-E7212BF1F585", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:sinamics_g180:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC515520-BB04-4849-ACE8-87ED5D591454", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*", "matchCriteriaId": "6218802E-D3B1-4197-A6B5-7343A50F7D88", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*", "matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:sinamics_s120cm:-:*:*:*:*:*:*:*", "matchCriteriaId": "C0ECF745-CE82-42C6-9EA0-12FBD89F6220", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D48682C-A39D-4A09-B904-50FA64A9D2A5", "vulnerable": true } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23." }, { "lang": "es", "value": "Los controladores Siemens SINAMICS S/G con firmware anterior a 4.6.11 no requiere autenticaci\u00f3n para sesiones FTP y TELNET, lo que permite a atacantes remotos evadir restricciones de acceso intencionadas a trav\u00e9s de trafico TCP al puerto (1) 21 o (2) 23." } ], "id": "CVE-2013-6920", "lastModified": "2024-11-21T01:59:58.257", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2013-12-07T00:55:04.147", "references": [ { "source": "cve@mitre.org", "tags": [ "US Government Resource" ], "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-338-01" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-742938.pdf" }, { "source": "cve@mitre.org", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-742938.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "US Government Resource" ], "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-338-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-742938.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-742938.pdf" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
cve-2013-6920
Vulnerability from cvelistv5
Published
2013-12-07 00:00
Modified
2024-08-06 17:53
Severity ?
EPSS score ?
Summary
Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23.
References
▼ | URL | Tags |
---|---|---|
http://ics-cert.us-cert.gov/advisories/ICSA-13-338-01 | x_refsource_MISC | |
http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-742938.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-742938.pdf | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T17:53:45.861Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-338-01" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-742938.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-742938.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2013-12-04T00:00:00", "descriptions": [ { "lang": "en", "value": "Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-02-10T14:06:15", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-338-01" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-742938.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-742938.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2013-6920", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-338-01", "refsource": "MISC", "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-338-01" }, { "name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-742938.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-742938.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-742938.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-742938.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2013-6920", "datePublished": "2013-12-07T00:00:00", "dateReserved": "2013-12-02T00:00:00", "dateUpdated": "2024-08-06T17:53:45.861Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }