Vulnerabilites related to siemens - sinamics_g120_firmware
cve-2019-10936
Vulnerability from cvelistv5
Published
2019-10-10 00:00
Modified
2024-08-04 22:40
Severity ?
EPSS score ?
Summary
Affected devices improperly handle large amounts of specially crafted UDP packets.
This could allow an unauthenticated remote attacker to trigger a denial of service condition.
References
Impacted products
{ containers: { adp: [ { affected: [ { cpes: [ "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "dk_standard_ethernet_controller_firmware", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:ek-ertec_200_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "ek-ertec_200_firmware", vendor: "siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:ek-ertec_200p_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "ek-ertec_200p_firmware", vendor: "siemens", versions: [ { lessThan: "4.6", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_cfu_pa", vendor: "siemens", versions: [ { lessThan: "v1.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:simatic_et200ecopn_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_et200ecopn_firmware", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:simatic_et200s_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_et200s_firmware", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:simatic_et_200al_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_et_200al_firmware", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:simatic_et_200m_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_et_200m_firmware", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:simatic_et_200mp_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_et_200mp_firmware", vendor: "siemens", versions: [ { lessThan: "v4.3.0", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:simatic_et_200pro_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_et_200pro_firmware", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:simatic_et_200s_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_et_200s_firmware", vendor: "siemens", versions: [ { lessThan: "v3.2.17", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:simatic_et_200sp_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_et_200sp_firmware", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_hmi_comfort_outdoor_panels", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0", vendor: "siemens", versions: [ { lessThan: "v4.2.1", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_profinet_driver", vendor: "siemens", versions: [ { lessThan: "v2.1", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_s7-300_cpu_314_firmware", vendor: "siemens", versions: [ { lessThan: "v3.2.17", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_s7-300_cpu_315-2_dp_firmware", vendor: "siemens", versions: [ { lessThan: "v3.2.17", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_315f-2_dp_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_s7-300_cpu_315f-2_dp_firmware", vendor: "siemens", versions: [ { lessThan: "v3.2.17", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_dp_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_s7-300_cpu_317-2_dp_firmware", vendor: "siemens", versions: [ { lessThan: "v3.2.17", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_pn\\/dp_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_s7-300_cpu_317-2_pn\\/dp_firmware", vendor: "siemens", versions: [ { lessThan: "v3.2.17", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_319-3_pn\\/dp_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_s7-300_cpu_319-3_pn\\/dp_firmware", vendor: "siemens", versions: [ { lessThan: "v3.2.17", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2_pn:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_s7-400_cpu_412-2_pn", vendor: "siemens", versions: [ { lessThan: "v7.0.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\\/dp:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_s7-400_cpu_414-3_pn\\/dp", vendor: "siemens", versions: [ { lessThan: "v7.0.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\\/dp:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_s7-400_cpu_416-3_pn\\/dp", vendor: "siemens", versions: [ { lessThanOrEqual: "v7.0.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:simatic_s7-400_h_v6_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_s7-400_h_v6_firmware", vendor: "siemens", versions: [ { lessThanOrEqual: "v6.0.9", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v6_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_s7-400_pn\\/dp_v6_firmware", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:simatic_s7-410_cpu_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_s7-410_cpu_firmware", vendor: "siemens", versions: [ { lessThan: "v8.2.2", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_s7-1200_cpu", vendor: "siemens", versions: [ { lessThan: "v4.4.0", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_s7-1500_cpu", vendor: "siemens", versions: [ { lessThan: "v2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_s7-1500_controller:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_s7-1500_controller", vendor: "siemens", versions: [ { lessThan: "v2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_tdc_cp51m1_firmware", vendor: "siemens", versions: [ { lessThan: "v1.1.8", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_tdc_cpu555_firmware", vendor: "siemens", versions: [ { lessThan: "v1.1.1", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:a:siemens:simatic_winac_rtx_2010:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_winac_rtx_2010", vendor: "siemens", versions: [ { lessThan: "v2010_sp3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\)_2010:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "simatic_winac_rtx_\\(f\\)_2010", vendor: "siemens", versions: [ { lessThan: "v2010_sp3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "sinamics_dcm", vendor: "siemens", versions: [ { lessThan: "v1.5_hf1", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "sinamics_dcp", vendor: "siemens", versions: [ { lessThan: "v1.3", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "sinamics_g110m", vendor: "siemens", versions: [ { lessThan: "v4.7_sp10_hf5", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "sinamics_g120", vendor: "siemens", versions: [ { lessThan: "v4.7_sp10_hf5", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "sinamics_g130", vendor: "siemens", versions: [ { lessThan: "v4.8", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "sinamics_g150", vendor: "siemens", versions: [ { lessThan: "v4.8", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "sinamics_gh150", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "sinamics_gl150", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "sinamics_gm150", vendor: "siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "sinamics_s110", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "sinamics_s120", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "sinamics_sl150", vendor: "siemens", versions: [ { lessThan: "v4.8", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "sinamics_sl150", vendor: "siemens", versions: [ { lessThan: "v4.7_hf33", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "sinamics_sm120", vendor: "siemens", versions: [ { lessThanOrEqual: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "sinumerik_828d", vendor: "siemens", versions: [ { lessThan: "v4.8_sp5", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "sinumerik_840d_sl", vendor: "siemens", versions: [ { lessThan: "v4.8_sp6", status: "affected", version: "0", versionType: "custom", }, ], }, { cpes: [ "cpe:2.3:h:siemens:siplus_s7-300_cpu_314:-:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "siplus_s7-300_cpu_314", vendor: "siemens", versions: [ { lessThan: "v3.3.17", status: "affected", version: "0", versionType: "custom", }, ], }, ], metrics: [ { other: { content: { id: "CVE-2019-10936", options: [ { Exploitation: "none", }, { Automatable: "yes", }, { "Technical Impact": "partial", }, ], role: "CISA Coordinator", timestamp: "2024-07-09T14:36:59.481395Z", version: "2.0.3", }, type: "ssvc", }, }, ], providerMetadata: { dateUpdated: "2024-07-09T15:59:12.602Z", orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0", shortName: "CISA-ADP", }, title: "CISA ADP Vulnrichment", }, { providerMetadata: { dateUpdated: "2024-08-04T22:40:15.253Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf", }, { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/html/ssa-473245.html", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { defaultStatus: "unknown", product: "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.6 Patch 01", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CFU PA", vendor: "Siemens", versions: [ { lessThan: "V1.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200AL IM 157-1 PN", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200M (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200MP IM 155-5 PN BA", vendor: "Siemens", versions: [ { lessThan: "V4.3.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200MP IM 155-5 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.4.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200MP IM 155-5 PN ST", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200MP IM 155-5 PN ST", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200pro IM 154-3 PN HF", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200pro IM 154-4 PN HF", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200pro IM 154-8 PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200pro IM 154-8F PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200pro IM 154-8FX PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200S IM 151-8 PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200S IM 151-8F PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN BA", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.2.1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN HS", vendor: "Siemens", versions: [ { lessThan: "V4.0.1", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN ST", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN ST", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN ST BA", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN ST BA", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN/2 HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN/3 HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.1", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "V2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 4AO U/I 4xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN: IO-Link Master", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200S (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC HMI Comfort Outdoor Panels (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC HMI KTP Mobile Panels", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC PN/PN Coupler", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.2.1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC PROFINET Driver", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.4.0", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.0", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-1500 Software Controller", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.0", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 314C-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 315-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 315F-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 315T-3 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 317-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 317F-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 317T-3 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 317TF-3 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 319-3 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 319F-3 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 CPU 412-2 PN V7", vendor: "Siemens", versions: [ { lessThan: "V7.0.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 CPU 414-3 PN/DP V7", vendor: "Siemens", versions: [ { lessThan: "V7.0.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 CPU 414F-3 PN/DP V7", vendor: "Siemens", versions: [ { lessThan: "V7.0.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 CPU 416-3 PN/DP V7", vendor: "Siemens", versions: [ { lessThan: "V7.0.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 CPU 416F-3 PN/DP V7", vendor: "Siemens", versions: [ { lessThan: "V7.0.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "V6.0.9", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V8.2.2", }, ], }, { defaultStatus: "unknown", product: "SIMATIC TDC CP51M1", vendor: "Siemens", versions: [ { lessThan: "V1.1.8", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC TDC CPU555", vendor: "Siemens", versions: [ { lessThan: "V1.1.1", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC WinAC RTX 2010", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2010 SP3", }, ], }, { defaultStatus: "unknown", product: "SIMATIC WinAC RTX F 2010", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2010 SP3", }, ], }, { defaultStatus: "unknown", product: "SINAMICS DCM", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.5 HF1", }, ], }, { defaultStatus: "unknown", product: "SINAMICS DCP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.3", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G110M V4.7 PN Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 SP10 HF5", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 SP10 HF5", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G130 V4.7 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < 4.8", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G150 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < 4.8", }, ], }, { defaultStatus: "unknown", product: "SINAMICS GH150 V4.7 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS GL150 V4.7 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS GM150 V4.7 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S110 Control Unit", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S150 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < 4.8", }, ], }, { defaultStatus: "unknown", product: "SINAMICS SL150 V4.7 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 HF33", }, ], }, { defaultStatus: "unknown", product: "SINAMICS SM120 V4.7 Control Unit", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SINUMERIK 828D", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 SP5", }, ], }, { defaultStatus: "unknown", product: "SINUMERIK 840D sl", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 SP6", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.4.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.4.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", vendor: "Siemens", versions: [ { lessThan: "V4.4.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN ST", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN ST", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200S IM 151-8 PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200S IM 151-8F PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", vendor: "Siemens", versions: [ { lessThan: "V4.2.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", vendor: "Siemens", versions: [ { lessThan: "V4.2.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL", vendor: "Siemens", versions: [ { lessThan: "V4.2.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST BA", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST BA", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS NET PN/PN Coupler", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.2.1", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-300 CPU 314C-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.3.17", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-300 CPU 315-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-300 CPU 315F-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-300 CPU 317-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-300 CPU 317F-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-400 CPU 414-3 PN/DP V7", vendor: "Siemens", versions: [ { lessThan: "V7.0.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-400 CPU 416-3 PN/DP V7", vendor: "Siemens", versions: [ { lessThan: "V7.0.3", status: "affected", version: "0", versionType: "custom", }, ], }, ], descriptions: [ { lang: "en", value: "Affected devices improperly handle large amounts of specially crafted UDP packets.\r\n\r\nThis could allow an unauthenticated remote attacker to trigger a denial of service condition.", }, ], metrics: [ { cvssV3_1: { baseScore: 7.5, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", version: "3.1", }, }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-400", description: "CWE-400: Uncontrolled Resource Consumption", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2024-07-09T12:03:55.957Z", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { url: "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf", }, { url: "https://cert-portal.siemens.com/productcert/html/ssa-473245.html", }, ], }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2019-10936", datePublished: "2019-10-10T00:00:00", dateReserved: "2019-04-08T00:00:00", dateUpdated: "2024-08-04T22:40:15.253Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
cve-2019-10923
Vulnerability from cvelistv5
Published
2019-10-10 13:49
Modified
2024-09-10 09:33
Severity ?
EPSS score ?
Summary
An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Version: All versions < V4.1.1 Patch 05 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-04T22:40:15.265Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { defaultStatus: "unknown", product: "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.1.1 Patch 05", }, ], }, { defaultStatus: "unknown", product: "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.5.0 Patch 01", }, ], }, { defaultStatus: "unknown", product: "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.5.0", }, ], }, { defaultStatus: "unknown", product: "SCALANCE X-200IRT family (incl. SIPLUS NET variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V5.2.1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200M (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200MP IM 155-5 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200MP IM 155-5 PN ST", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200pro IM 154-3 PN HF", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200pro IM 154-4 PN HF", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200pro IM 154-8 PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200pro IM 154-8F PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200pro IM 154-8FX PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200S IM 151-8 PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200S IM 151-8F PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN ST", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP IM 155-6 PN ST BA", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 4AO U/I 4xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200ecoPN: IO-Link Master", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET200S (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC NET CP 1604", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.8", }, ], }, { defaultStatus: "unknown", product: "SIMATIC NET CP 1616", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.8", }, ], }, { defaultStatus: "unknown", product: "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 314C-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 315-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 315F-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 315T-3 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 317-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 317F-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 317T-3 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 317TF-3 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 319-3 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 319F-3 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 CPU 412-2 PN V7", vendor: "Siemens", versions: [ { lessThan: "V7.0.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 CPU 414-3 PN/DP V7", vendor: "Siemens", versions: [ { lessThan: "V7.0.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 CPU 414F-3 PN/DP V7", vendor: "Siemens", versions: [ { lessThan: "V7.0.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 CPU 416-3 PN/DP V7", vendor: "Siemens", versions: [ { lessThan: "V7.0.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 CPU 416F-3 PN/DP V7", vendor: "Siemens", versions: [ { lessThan: "V7.0.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { lessThan: "*", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC WinAC RTX 2010", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2010 SP3", }, ], }, { defaultStatus: "unknown", product: "SIMATIC WinAC RTX F 2010", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2010 SP3", }, ], }, { defaultStatus: "unknown", product: "SIMOTION", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS DCM", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.5 HF1", }, ], }, { defaultStatus: "unknown", product: "SINAMICS DCP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.3", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G110M V4.7 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 SP10 HF5", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 SP10 HF5", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G130 V4.7 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 HF29", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G150 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8", }, ], }, { defaultStatus: "unknown", product: "SINAMICS GH150 V4.7 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS GL150 V4.7 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS GM150 V4.7 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S110 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 HF34", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S150 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8", }, ], }, { defaultStatus: "unknown", product: "SINAMICS SL150 V4.7 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 HF33", }, ], }, { defaultStatus: "unknown", product: "SINAMICS SM120 V4.7 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINUMERIK 828D", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 SP5", }, ], }, { defaultStatus: "unknown", product: "SINUMERIK 840D sl", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 SP5", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN ST", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200S IM 151-8 PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200S IM 151-8F PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN HF", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", vendor: "Siemens", versions: [ { lessThan: "V4.2.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST BA", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", vendor: "Siemens", versions: [ { lessThan: "V4.1.0", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-300 CPU 314C-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.3.17", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-300 CPU 315-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-300 CPU 315F-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-300 CPU 317-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-300 CPU 317F-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.17", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-400 CPU 414-3 PN/DP V7", vendor: "Siemens", versions: [ { lessThan: "V7.0.3", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-400 CPU 416-3 PN/DP V7", vendor: "Siemens", versions: [ { lessThan: "V7.0.3", status: "affected", version: "0", versionType: "custom", }, ], }, ], descriptions: [ { lang: "en", value: "An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.", }, ], metrics: [ { cvssV3_1: { baseScore: 7.5, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", version: "3.1", }, }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-400", description: "CWE-400: Uncontrolled Resource Consumption", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2024-09-10T09:33:22.534Z", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { url: "https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf", }, { url: "https://cert-portal.siemens.com/productcert/html/ssa-349422.html", }, ], }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2019-10923", datePublished: "2019-10-10T13:49:24", dateReserved: "2019-04-08T00:00:00", dateUpdated: "2024-09-10T09:33:22.534Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
Vulnerability from fkie_nvd
Published
2019-10-10 14:15
Modified
2024-11-21 04:20
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-349422.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | cp1604_firmware | * | |
siemens | cp1604 | - | |
siemens | cp1616_firmware | * | |
siemens | cp1616 | - | |
siemens | dk_standard_ethernet_controller_firmware | * | |
siemens | dk_standard_ethernet_controller_firmware | 4.1.1 | |
siemens | dk_standard_ethernet_controller_firmware | 4.1.1 | |
siemens | dk_standard_ethernet_controller | - | |
siemens | ek-ertec_200_firmware | * | |
siemens | ek-ertec_200_firmware | 4.5.0 | |
siemens | ek-ertec_200 | - | |
siemens | ek-ertec_200p_firmware | * | |
siemens | ek-ertec_200p | - | |
siemens | scalance_x-200irt_firmware | * | |
siemens | scalance_x-200irt | - | |
siemens | simatic_et_200m_firmware | * | |
siemens | simatic_et_200m | - | |
siemens | simatic_et_200s_firmware | * | |
siemens | simatic_et_200s | - | |
siemens | simatic_et_200ecopn_firmware | * | |
siemens | simatic_et_200ecopn | - | |
siemens | simatic_pn\/pn_coupler_6es7158-3ad01-0xa0_firmware | * | |
siemens | simatic_pn\/pn_coupler_6es7158-3ad01-0xa0 | - | |
siemens | simatic_s7-300_cpu_firmware | * | |
siemens | simatic_s7-300_cpu | - | |
siemens | simatic_s7-300_cpu_312_ifm_firmware | * | |
siemens | simatic_s7-300_cpu_312_ifm | - | |
siemens | simatic_s7-300_cpu_313_firmware | * | |
siemens | simatic_s7-300_cpu_313 | - | |
siemens | simatic_s7-300_cpu_314_firmware | * | |
siemens | simatic_s7-300_cpu_314 | - | |
siemens | simatic_s7-300_cpu_314_ifm_firmware | * | |
siemens | simatic_s7-300_cpu_314_ifm | - | |
siemens | simatic_s7-300_cpu_315_firmware | * | |
siemens | simatic_s7-300_cpu_315 | - | |
siemens | simatic_s7-300_cpu_315-2_dp_firmware | * | |
siemens | simatic_s7-300_cpu_315-2_dp | - | |
siemens | simatic_s7-300_cpu_316-2_dp_firmware | * | |
siemens | simatic_s7-300_cpu_316-2_dp | - | |
siemens | simatic_s7-300_cpu_318-2_firmware | * | |
siemens | simatic_s7-300_cpu_318-2 | - | |
siemens | simatic_s7-400_v6_firmware | * | |
siemens | simatic_s7-400_v6 | - | |
siemens | simatic_s7-400_pn_v7_firmware | * | |
siemens | simatic_s7-400_pn_v7 | - | |
siemens | simatic_s7-400_dp_v7_firmware | * | |
siemens | simatic_s7-400_dp_v7 | - | |
siemens | simatic_winac_rtx_\(f\)_firmware | * | |
siemens | simatic_winac_rtx_\(f\)_firmware | 2010 | |
siemens | simatic_winac_rtx_\(f\)_firmware | 2010 | |
siemens | simatic_winac_rtx_\(f\)_firmware | 2010 | |
siemens | simatic_winac_rtx_\(f\) | - | |
siemens | simotion_firmware | * | |
siemens | simotion | - | |
siemens | sinamics_dcm_firmware | * | |
siemens | sinamics_dcm_firmware | 1.5 | |
siemens | sinamics_dcm | - | |
siemens | sinamics_dcp_firmware | * | |
siemens | sinamics_dcp | - | |
siemens | sinamics_g110m_firmware | * | |
siemens | sinamics_g110m_firmware | 4.7 | |
siemens | sinamics_g110m | - | |
siemens | sinamics_g120_firmware | * | |
siemens | sinamics_g120_firmware | 4.7 | |
siemens | sinamics_g120 | - | |
siemens | sinamics_g130_firmware | * | |
siemens | sinamics_g130_firmware | 4.7 | |
siemens | sinamics_g130 | - | |
siemens | sinamics_g150_firmware | * | |
siemens | sinamics_g150 | - | |
siemens | sinamics_gh150_firmware | * | |
siemens | sinamics_gh150_firmware | 4.8 | |
siemens | sinamics_gh150 | - | |
siemens | sinamics_gl150_firmware | * | |
siemens | sinamics_gl150_firmware | 4.8 | |
siemens | sinamics_gl150 | - | |
siemens | sinamics_gm150_firmware | * | |
siemens | sinamics_gm150_firmware | 4.8 | |
siemens | sinamics_gm150 | - | |
siemens | sinamics_s110_firmware | * | |
siemens | sinamics_s110 | - | |
siemens | sinamics_s120_firmware | * | |
siemens | sinamics_s120_firmware | 4.7 | |
siemens | sinamics_s120 | - | |
siemens | sinamics_s150_firmware | * | |
siemens | sinamics_s150 | - | |
siemens | sinamics_sl150_firmware | * | |
siemens | sinamics_sl150_firmware | 4.7 | |
siemens | sinamics_sl150 | - | |
siemens | sinamics_sm120_firmware | * | |
siemens | sinamics_sm120 | - | |
siemens | sinumerik_828d | * | |
siemens | sinumerik_828d | 4.8 | |
siemens | sinumerik_828d | 4.8 | |
siemens | sinumerik_828d | 4.8 | |
siemens | sinumerik_828d | 4.8 | |
siemens | sinumerik_828d | 4.8 | |
siemens | sinumerik_840d_sl | * |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:cp1604_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "1D00494F-8BC7-44C1-816E-0266920F8659", versionEndExcluding: "2.8", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:cp1604:-:*:*:*:*:*:*:*", matchCriteriaId: "6222006F-09D7-49F7-B8C7-4D94298A8F6A", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:cp1616_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0B1E2552-2661-40FB-A88A-4383064A58F3", versionEndExcluding: "2.8", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:cp1616:-:*:*:*:*:*:*:*", matchCriteriaId: "184365A2-BAD2-4926-ACEE-F71E018D3CE5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0FE40195-DE5A-4B9C-9455-FAF92FF090D0", versionEndExcluding: "4.1.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:*", matchCriteriaId: "9B339839-3D74-4E13-9EB6-24CA46F991A5", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:p4:*:*:*:*:*:*", matchCriteriaId: "92416826-BD34-4611-A5FE-F315C9E8727F", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*", matchCriteriaId: "53DF35F1-94FF-4D0B-9FA2-E8B0AFAEA5FF", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:ek-ertec_200_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "191FC7FB-791D-44E9-99C8-6CE15C99D057", versionEndExcluding: "4.5.0", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:ek-ertec_200_firmware:4.5.0:-:*:*:*:*:*:*", matchCriteriaId: "F894A35F-CB1A-4653-9157-DBCE16247D09", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:ek-ertec_200:-:*:*:*:*:*:*:*", matchCriteriaId: "B47CF3BB-08E4-4B86-B793-8253C172D846", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "D2859C30-0E12-437E-A07A-7B25D841CFDE", versionEndExcluding: "4.5.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*", matchCriteriaId: "FB75CD44-5223-40A7-A835-111BF3C25D23", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:scalance_x-200irt_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4E299AC3-800C-4C27-956A-C7B8DF5F00D0", versionEndExcluding: "5.2.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:scalance_x-200irt:-:*:*:*:*:*:*:*", matchCriteriaId: "94C7BE35-D3A6-488C-BB3D-D17D65DF4B80", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "14E56570-5C20-40BD-BF0B-F6ED06AFC8F7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*", matchCriteriaId: "7037E46B-4FE5-4693-B6A6-B5AF7B652C4F", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "BB063929-AAB0-4FF8-BCA3-71BA80517B1A", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*", matchCriteriaId: "A1EC40E7-F004-446C-B5C9-0AB9911105E0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "3EE0B998-E408-408F-8F78-5E90F74E9C9B", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*", matchCriteriaId: "0259EAE9-0CA0-49A5-A573-8339604A181B", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "17C73DE7-4462-4C7B-8475-D5E6075C8E00", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0:-:*:*:*:*:*:*:*", matchCriteriaId: "2155DBBF-98F3-42A2-8DB1-0BB27984D0E0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "C87674A8-B518-4910-B03D-FFF4D5A7B627", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*", matchCriteriaId: "602FB384-0DB2-488C-B3CC-96E3A2882976", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_cpu_312_ifm_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7B0C6327-7BF6-4B96-82A8-D750007869EE", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300_cpu_312_ifm:-:*:*:*:*:*:*:*", matchCriteriaId: "CCFCAA2B-71FE-4DB4-B8B0-F5FD1254C331", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_cpu_313_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "3EF9F3FB-FBBA-42A8-9A90-FE34703274B5", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300_cpu_313:-:*:*:*:*:*:*:*", matchCriteriaId: "4E6E900F-63C1-4E50-9DCD-26CE760E5275", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8F2F0659-CD37-4AA9-B7D5-44639515533C", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*", matchCriteriaId: "78399465-EED5-4EBD-A2E1-6FE0BD01EDB4", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_ifm_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "07AD63B6-B05C-4BBF-812D-379C4D8F8CC7", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300_cpu_314_ifm:-:*:*:*:*:*:*:*", matchCriteriaId: "8BE7963C-7AFF-495B-9F0B-28FB393443FD", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_cpu_315_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7F2A0C75-E360-4E3D-85DA-878E39054E26", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300_cpu_315:-:*:*:*:*:*:*:*", matchCriteriaId: "E3962681-E32E-4BD1-8C71-8768248691D4", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "488F0774-43DA-455D-905C-C514A0192260", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*", matchCriteriaId: "E8FD8E6D-0527-4215-B6F0-5824011433FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_cpu_316-2_dp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "F103C351-99C9-4F7D-B69A-D8A876F57504", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300_cpu_316-2_dp:-:*:*:*:*:*:*:*", matchCriteriaId: "644AD6A8-AEDE-4F1C-92F8-836877A81310", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_cpu_318-2_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "BA99549B-5E95-445A-A95B-1CDA7014686B", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300_cpu_318-2:-:*:*:*:*:*:*:*", matchCriteriaId: "FF58C652-E74D-4B57-A7C5-08D7446863D5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-400_v6_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "C7B2893A-F0B4-4795-AF1C-DFF17D493929", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-400_v6:-:*:*:*:*:*:*:*", matchCriteriaId: "A6445275-2AEF-4285-BE7A-67F20182481C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-400_pn_v7_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "1B6B9D8B-D7BA-4D72-97C7-7BBEB49802F7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-400_pn_v7:-:*:*:*:*:*:*:*", matchCriteriaId: "E4F8215E-E737-4CD5-B7D9-57FE4A2A2FE5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-400_dp_v7_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "72F7B870-35A1-4900-8104-1303F291E29A", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-400_dp_v7:-:*:*:*:*:*:*:*", matchCriteriaId: "ABE9F7D2-22C7-4E7C-99C3-4A88CDD2CDB7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "9D03BD73-51ED-42E0-A552-C32BB7A935B2", versionEndExcluding: "2010", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:2010:-:*:*:*:*:*:*", matchCriteriaId: "7151A19C-0AE5-4F66-9E3D-8BF675A8430C", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:2010:sp1:*:*:*:*:*:*", matchCriteriaId: "BEEB72F4-AE57-49DD-8876-1BCA7B805692", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:2010:sp2:*:*:*:*:*:*", matchCriteriaId: "7929F123-AC76-4F49-940F-558CABC25E75", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\):-:*:*:*:*:*:*:*", matchCriteriaId: "C6143A7A-9D01-4D13-B0F5-2AD0DD6DA5EE", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "080E9ADC-C88F-45D4-8453-6E5E25371476", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*", matchCriteriaId: "879CF09E-4735-4A73-8E7B-215F2701F7E0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "84B1F9B1-4248-4A4C-A8BB-77475A0E9B9B", versionEndExcluding: "1.5", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.5:-:*:*:*:*:*:*", matchCriteriaId: "F2F99FFB-C312-4080-9580-84AFB7C9FA09", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*", matchCriteriaId: "A1A43D34-ECA3-4330-B85F-02BDD1D22149", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "83803F1C-4842-43BB-B903-C2E91FF7DC08", versionEndExcluding: "1.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*", matchCriteriaId: "B75F50CA-7371-4BC7-8D8A-13F8BC69E4EB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "775C90BB-C026-435C-889A-517EF85656C5", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "CAA92AC6-7DA0-418D-A13F-69268DFD7966", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*", matchCriteriaId: "D61D3E9C-1346-4354-BCD9-B02F67500C41", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_g120_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B1DBCA1A-27F3-4E9A-9F89-65E82A68DE4A", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_g120_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "94CB2F3E-AAA1-4472-BFD4-4E6E1B663FF5", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*", matchCriteriaId: "61A60DCE-384B-43A4-A669-973FB8ECA932", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4B3B0706-47CD-43FB-8E3A-7EEEF020AFBA", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "1D36CF8D-6DA4-49ED-9EF1-F96292F671EE", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*", matchCriteriaId: "373DBE44-AC28-4D04-93BB-35CD8C60E899", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "07F8091F-C17A-4913-A1BC-A7BA376B595F", versionEndExcluding: "4.8", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*", matchCriteriaId: "2296CA65-0E89-4BCB-8003-E7212BF1F585", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6E231DE7-8B8D-41A3-A163-CE8EF50AF9D0", versionEndExcluding: "4.8", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_gh150_firmware:4.8:-:*:*:*:*:*:*", matchCriteriaId: "6D076504-AFE3-4C51-80E5-C5992CA7D511", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", matchCriteriaId: "BF977545-395A-4C34-BB22-A1047B5B6E85", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "3653DA37-DB23-41E0-8CE8-838E384AA40A", versionEndExcluding: "4.8", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*", matchCriteriaId: "0F86A334-10F9-4DFB-A421-CBCAFD86C8C2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", matchCriteriaId: "DED7F33B-D475-4232-8683-48554A6729F7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0E25804D-D943-4C2A-9C78-AAC61F7BA4FF", versionEndExcluding: "4.8", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.8:-:*:*:*:*:*:*", matchCriteriaId: "06B69CD4-3AEC-4014-81DB-33805A44A5D3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", matchCriteriaId: "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_s110_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "243FFEA3-7193-45EA-B865-E9CA1D6656FE", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*", matchCriteriaId: "6218802E-D3B1-4197-A6B5-7343A50F7D88", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "77A0BE57-1A9A-4564-9C53-CF47DEEF7991", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "376556D0-1AE2-4F80-B3CE-C0251E35C326", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*", matchCriteriaId: "E5A824BD-935F-4E53-8313-C5544B0489C7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "22AFC8AE-8AF0-4418-B251-4CE293B9DCD8", versionEndExcluding: "4.8", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*", matchCriteriaId: "0D48682C-A39D-4A09-B904-50FA64A9D2A5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "30E52510-9306-42B8-A517-A6BBD34B8B9D", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "58A71910-E54F-426B-BAB1-260AEFD8EF6E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", matchCriteriaId: "C6619B0F-7CDC-40A6-89B2-C6067AF45214", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "CFFE3048-EEB0-48A0-BED0-8647284B022B", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", matchCriteriaId: "444DD77F-DB65-4766-A89D-7A679B4CA1E1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:sinumerik_828d:*:*:*:*:*:*:*:*", matchCriteriaId: "328F0192-B34D-481C-8964-226317439966", versionEndExcluding: "4.8", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:sinumerik_828d:4.8:-:*:*:*:*:*:*", matchCriteriaId: "C7936CF6-DC07-4550-9FEC-823A2F49096D", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp1:*:*:*:*:*:*", matchCriteriaId: "BEE7D914-F2DE-4D8C-BFB2-7AD16650CD3F", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp2:*:*:*:*:*:*", matchCriteriaId: "BDBAEDBC-6A76-495D-9BC7-BA687F32EE40", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp3:*:*:*:*:*:*", matchCriteriaId: "45EF769B-1EB1-4D2D-84C5-8005EF1EE1EF", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp4:*:*:*:*:*:*", matchCriteriaId: "48EE5859-5450-4078-94E7-E525B999A837", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:sinumerik_840d_sl:*:*:*:*:*:*:*:*", matchCriteriaId: "9FFC86D6-F312-4097-91A6-79C78502323F", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, ], cveTags: [], descriptions: [ { lang: "en", value: "An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.", }, { lang: "es", value: "Se ha identificado una vulnerabilidad en Development/Evaluation Kits para PROFINET IO: DK Standard Ethernet Controller (Todas las versiones anteriores a la versión V4.1.1 Patch 05), Development/Evaluation Kits para PROFINET IO: EK-ERTEC 200 (Todas las versiones anteriores a la versión V4.5.0 Patch 01), Development/Evaluation Kits para PROFINET IO: EK-ERTEC 200P (Todas las versiones anteriores a la versión V4.5.0), familia de switches SCALANCE X-200IRT (incluidas las variantes SIPLUS NET) (Todas las versiones anteriores a la versión V5.2.1), SIMATIC ET200M (incluidas las variantes SIPLUS) (Todas las versiones), SIMATIC ET200S (incluidas las variantes SIPLUS) (Todas las versiones), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 4AO U/I 4xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 (Todas las versiones), SIMATIC ET200ecoPN: IO-Link Master (Todas las versiones), SIMATIC ET200pro (Todas las versiones), SIMATIC NET CP 1604 (Todas las versiones anteriores a la versión V2.8), SIMATIC NET CP 1616 (Todas las versiones anteriores a la versión V2.8), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incluida la variante SIPLUS NET) (Todas las versiones), familia SIMATIC S7-300 CPU (incluyendo las variantes relacionadas ET200 CPUs y SIPLUS) (Todas las versiones anteriores a la versión V3.X.17), familia SIMATIC S7-400 PN/DP V6 y anteriores CPU (incluidas las variantes SIPLUS) (Todas las versiones), familia SIMATIC S7-400 PN/DP V7 CPU (incluidas las variantes SIPLUS) (Todas las versiones), SIMATIC WinAC RTX (F) 2010 (Todas las versiones anteriores a la versión SIMATIC WinAC RTX 2010 SP3), SIMOTION (incluidas las variantes SIPLUS) (Todas las versiones), SINAMICS DCM (Todas las versiones anteriores a la versión V1.5 HF1), SINAMICS DCP (Todas las versiones anteriores a la versión V1.3), SINAMICS G110M V4.7 Control Unit (Todas las versiones anteriores a la versión V4.7 SP10 HF5), SINAMICS G120 V4.7 Control Unit (incluidas las variantes SIPLUS) (Todas las versiones anteriores a la versión V4.7 SP10 HF5), SINAMICS G130 V4.7 Control Unit (Todas las versiones anteriores a la versión V4.7 HF29), SINAMICS G150 Control Unit (Todas las versiones anteriores a la versión V4.8), SINAMICS GH150 V4.7 Control Unit (Todas las versiones), SINAMICS GL150 V4.7 Control Unit (Todas las versiones), SINAMICS GM150 V4.7 Control Unit (Todas las versiones), SINAMICS S110 Control Unit (Todas las versiones), SINAMICS S120 V4.7 Control Unit and CBE20 (incluidas las variantes SIPLUS) (Todas las versiones anteriores a la versión V4.7 HF34), SINAMICS S150 Control Unit (Todas las versiones anteriores a la versión V4.8), SINAMICS SL150 V4.7 Control Unit (Todas las versiones anteriores a la versión V4.7 HF33), SINAMICS SM120 V4.7 Control Unit (Todas las versiones), SINUMERIK 828D (Todas las versiones anteriores a la versión V4.8 SP5), SINUMERIK 840D sl (Todas las versiones). Un atacante con acceso de red a un producto afectado puede causar una condición de denegación de servicio al romper la sincronización en tiempo real (IRT) de la instalación afectada. La vulnerabilidad de seguridad podría ser explotada por un atacante no autenticado con acceso de red a la instalación afectada. No se requiere interacción del usuario para explotar esta vulnerabilidad de seguridad. La vulnerabilidad afecta la disponibilidad de las instalaciones afectadas", }, ], id: "CVE-2019-10923", lastModified: "2024-11-21T04:20:09.600", metrics: { cvssMetricV2: [ { acInsufInfo: false, baseSeverity: "MEDIUM", cvssData: { accessComplexity: "LOW", accessVector: "NETWORK", authentication: "NONE", availabilityImpact: "PARTIAL", baseScore: 5, confidentialityImpact: "NONE", integrityImpact: "NONE", vectorString: "AV:N/AC:L/Au:N/C:N/I:N/A:P", version: "2.0", }, exploitabilityScore: 10, impactScore: 2.9, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: false, }, ], cvssMetricV31: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "productcert@siemens.com", type: "Secondary", }, { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "nvd@nist.gov", type: "Secondary", }, ], }, published: "2019-10-10T14:15:14.503", references: [ { source: "productcert@siemens.com", url: "https://cert-portal.siemens.com/productcert/html/ssa-349422.html", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-400", }, ], source: "productcert@siemens.com", type: "Primary", }, { description: [ { lang: "en", value: "CWE-400", }, ], source: "nvd@nist.gov", type: "Secondary", }, ], }
Vulnerability from fkie_nvd
Published
2019-10-10 14:15
Modified
2024-11-21 04:20
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Affected devices improperly handle large amounts of specially crafted UDP packets.
This could allow an unauthenticated remote attacker to trigger a denial of service condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-473245.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-473245.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | dk_standard_ethernet_controller_firmware | * | |
siemens | dk_standard_ethernet_controller | - | |
siemens | ek-ertec_200_firmware | * | |
siemens | ek-ertec_200 | - | |
siemens | ek-ertec_200p_firmware | * | |
siemens | ek-ertec_200p_firmware | 4.6 | |
siemens | ek-ertec_200p | - | |
siemens | simatic_cfu_pa_firmware | * | |
siemens | simatic_cfu_pa | - | |
siemens | simatic_et_200al_firmware | * | |
siemens | simatic_et_200al | - | |
siemens | simatic_et_200m_firmware | * | |
siemens | simatic_et_200m | - | |
siemens | simatic_et_200mp_im_155-5_pn_ba_firmware | * | |
siemens | simatic_et_200mp_im_155-5_pn_ba | - | |
siemens | simatic_et_200mp_im_155-5_pn_hf_firmware | * | |
siemens | simatic_et_200mp_im_155-5_pn_hf | - | |
siemens | simatic_et_200mp_im_155-5_pn_st_firmware | * | |
siemens | simatic_et_200mp_im_155-5_pn_st | - | |
siemens | simatic_et_200s_firmware | * | |
siemens | simatic_et_200s | - | |
siemens | simatic_et_200sp_im_155-6_pn_ba_firmware | * | |
siemens | simatic_et_200sp_im_155-6_pn_ba | - | |
siemens | simatic_et_200sp_im_155-6_pn_ha_firmware | * | |
siemens | simatic_et_200sp_im_155-6_pn_ha | - | |
siemens | simatic_et_200sp_im_155-6_pn_hf_firmware | * | |
siemens | simatic_et_200sp_im_155-6_pn_hf | - | |
siemens | simatic_et_200sp_im_155-6_pn_hs_firmware | * | |
siemens | simatic_et_200sp_im_155-6_pn_hs | - | |
siemens | simatic_et_200sp_im_155-6_pn_st_firmware | * | |
siemens | simatic_et_200sp_im_155-6_pn_st | - | |
siemens | simatic_et_200sp_im_155-6_pn\/2_hf_firmware | * | |
siemens | simatic_et_200sp_im_155-6_pn\/2_hf | - | |
siemens | simatic_et_200sp_im_155-6_pn\/3_hf_firmware | * | |
siemens | simatic_et_200sp_im_155-6_pn\/3_hf | - | |
siemens | simatic_et_200ecopn_firmware | * | |
siemens | simatic_et_200ecopn | - | |
siemens | simatic_et_200pro_firmware | * | |
siemens | simatic_et_200pro | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels | - | |
siemens | simatic_pn\/pn_coupler_firmware | * | |
siemens | simatic_pn\/pn_coupler | - | |
siemens | simatic_profinet_driver_firmware | * | |
siemens | simatic_profinet_driver | - | |
siemens | simatic_s7-1200_cpu_firmware | * | |
siemens | simatic_s7-1200_cpu | - | |
siemens | simatic_s7-1200_cpu_1211c_firmware | * | |
siemens | simatic_s7-1200_cpu_1211c | - | |
siemens | simatic_s7-1200_cpu_1212c_firmware | * | |
siemens | simatic_s7-1200_cpu_1212c | - | |
siemens | simatic_s7-1200_cpu_1214c_firmware | * | |
siemens | simatic_s7-1200_cpu_1214c | - | |
siemens | simatic_s7-1500_cpu_firmware | * | |
siemens | simatic_s7-1500_cpu | - | |
siemens | simatic_s7-1500s_cpu_firmware | * | |
siemens | simatic_s7-1500s_cpu | - | |
siemens | simatic_s7-1500t_cpu_firmware | * | |
siemens | simatic_s7-1500t_cpu | - | |
siemens | simatic_s7-1500_cpu_1518_firmware | * | |
siemens | simatic_s7-1500_cpu_1518 | - | |
siemens | simatic_s7-1500_cpu_1511c_firmware | * | |
siemens | simatic_s7-1500_cpu_1511c | - | |
siemens | simatic_s7-1500_cpu_1512c_firmware | * | |
siemens | simatic_s7-1500_cpu_1512c | - | |
siemens | simatic_s7-300_cpu_firmware | * | |
siemens | simatic_s7-300_cpu | - | |
siemens | simatic_s7-300_cpu_312_ifm_firmware | * | |
siemens | simatic_s7-300_cpu_312_ifm | - | |
siemens | simatic_s7-300_cpu_313_firmware | * | |
siemens | simatic_s7-300_cpu_313 | - | |
siemens | simatic_s7-300_cpu_314_firmware | * | |
siemens | simatic_s7-300_cpu_314 | - | |
siemens | simatic_s7-300_cpu_314_ifm_firmware | * | |
siemens | simatic_s7-300_cpu_314_ifm | - | |
siemens | simatic_s7-300_cpu_315_firmware | * | |
siemens | simatic_s7-300_cpu_315 | - | |
siemens | simatic_s7-300_cpu_315-2_dp_firmware | * | |
siemens | simatic_s7-300_cpu_315-2_dp | - | |
siemens | simatic_s7-300_cpu_316-2_dp_firmware | * | |
siemens | simatic_s7-300_cpu_316-2_dp | - | |
siemens | simatic_s7-300_cpu_318-2_firmware | * | |
siemens | simatic_s7-300_cpu_318-2 | - | |
siemens | simatic_s7-400_pn_v7_firmware | * | |
siemens | simatic_s7-400_pn_v7 | - | |
siemens | simatic_s7-400_dp_v7_firmware | * | |
siemens | simatic_s7-400_dp_v7 | - | |
siemens | simatic_s7-400_v6_firmware | * | |
siemens | simatic_s7-400_v6 | - | |
siemens | simatic_s7-400h_v6_firmware | * | |
siemens | simatic_s7-400h_v6 | - | |
siemens | simatic_s7-410_v8_firmware | * | |
siemens | simatic_s7-410_v8 | - | |
siemens | simatic_winac_rtx_\(f\)_firmware | * | |
siemens | simatic_winac_rtx_\(f\)_firmware | 2010 | |
siemens | simatic_winac_rtx_\(f\)_2010 | - | |
siemens | sinamics_dcm_firmware | * | |
siemens | sinamics_dcm_firmware | 1.5 | |
siemens | sinamics_dcm | - | |
siemens | sinamics_dcp_firmware | * | |
siemens | sinamics_dcp | - | |
siemens | sinamics_g110m_firmware | * | |
siemens | sinamics_g110m_firmware | 4.7 | |
siemens | sinamics_g110m | - | |
siemens | sinamics_g120_firmware | * | |
siemens | sinamics_g120_firmware | 4.7 | |
siemens | sinamics_g120 | - | |
siemens | sinamics_g130_firmware | * | |
siemens | sinamics_g130_firmware | 5.2 | |
siemens | sinamics_g130 | - | |
siemens | sinamics_g150_firmware | * | |
siemens | sinamics_g150_firmware | 5.2 | |
siemens | sinamics_g150 | - | |
siemens | sinamics_gl150_firmware | * | |
siemens | sinamics_gl150_firmware | 4.8 | |
siemens | sinamics_gl150 | - | |
siemens | sinamics_gm150_firmware | * | |
siemens | sinamics_gm150_firmware | 4.8 | |
siemens | sinamics_gm150 | - | |
siemens | sinamics_s110_firmware | * | |
siemens | sinamics_s110 | - | |
siemens | sinamics_s120_firmware | * | |
siemens | sinamics_s120_firmware | 5.2 | |
siemens | sinamics_s120 | - | |
siemens | sinamics_s150_firmware | * | |
siemens | sinamics_s150_firmware | 5.2 | |
siemens | sinamics_s150 | - | |
siemens | sinamics_sl150_firmware | * | |
siemens | sinamics_sl150_firmware | 4.7 | |
siemens | sinamics_sl150 | - | |
siemens | sinamics_sm120_firmware | - | |
siemens | sinamics_sm120 | - | |
siemens | sinumerik_828d | * | |
siemens | sinumerik_828d | 4.8 | |
siemens | sinumerik_828d | 4.8 | |
siemens | sinumerik_828d | 4.8 | |
siemens | sinumerik_828d | 4.8 | |
siemens | sinumerik_828d | 4.8 | |
siemens | sinumerik_840d_sl | * |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E19343EA-5ECA-4263-A568-DAEA04425F86", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*", matchCriteriaId: "53DF35F1-94FF-4D0B-9FA2-E8B0AFAEA5FF", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:ek-ertec_200_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "70D5CDF4-A134-402E-A4E9-4BBA19082397", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:ek-ertec_200:-:*:*:*:*:*:*:*", matchCriteriaId: "B47CF3BB-08E4-4B86-B793-8253C172D846", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2773F4B7-095E-4A33-93F2-765FA58B828C", versionEndExcluding: "4.6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:ek-ertec_200p_firmware:4.6:-:*:*:*:*:*:*", matchCriteriaId: "9E7753EE-DF23-4838-B3B4-7C43C550519C", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*", matchCriteriaId: "FB75CD44-5223-40A7-A835-111BF3C25D23", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "ABA8C0E5-E6AA-4BF2-925F-0041C382A416", versionEndExcluding: "1.2.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*", matchCriteriaId: "B6C1E4CC-2657-4383-83D8-5C8F88B12755", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "24E01824-4942-4400-A8C2-43A5772C2968", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*", matchCriteriaId: "34C17B00-34B5-4A15-9333-252BE2975F37", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "14E56570-5C20-40BD-BF0B-F6ED06AFC8F7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*", matchCriteriaId: "7037E46B-4FE5-4693-B6A6-B5AF7B652C4F", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_ba_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B4458E08-9864-452E-B95E-A46C5600D488", versionEndExcluding: "4.3.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_ba:-:*:*:*:*:*:*:*", matchCriteriaId: "9AF349D2-2560-4C60-8729-4B6CCDC52347", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_hf_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "00743200-D240-4CBC-8652-555F5E89B042", versionEndExcluding: "4.4.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_hf:-:*:*:*:*:*:*:*", matchCriteriaId: "AB9BFB03-D366-4F23-9477-D6133BD021CF", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_st_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "ACDF9AF3-DDB9-41A8-90C5-2A95A51D5EDE", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_st:-:*:*:*:*:*:*:*", matchCriteriaId: "4B48C0A4-072A-4744-94A5-FC4741F4A029", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "BB063929-AAB0-4FF8-BCA3-71BA80517B1A", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*", matchCriteriaId: "A1EC40E7-F004-446C-B5C9-0AB9911105E0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_ba_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8A1327FC-E785-4AA7-BC73-CC61CEED832D", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_ba:-:*:*:*:*:*:*:*", matchCriteriaId: "4C0300D2-1A87-4F61-9444-C1D23E3E6033", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_ha_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "17B7ED41-6AC7-4D34-A94E-61AECFA088EA", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_ha:-:*:*:*:*:*:*:*", matchCriteriaId: "34131306-1591-42B3-B235-4265F918CBDA", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_hf_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "67DAE64A-6E78-452E-9812-242769378ED8", versionEndExcluding: "4.2.2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_hf:-:*:*:*:*:*:*:*", matchCriteriaId: "527AE806-5C00-4C44-940F-88032AD8120D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_hs_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "AAAA8667-C792-45E4-AE5E-C194B5B76366", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_hs:-:*:*:*:*:*:*:*", matchCriteriaId: "455EC7E5-236B-43E6-86E7-702FAFCCCB15", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_st_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "918CBE10-D912-446B-B8B3-843B0089CB7A", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_st:-:*:*:*:*:*:*:*", matchCriteriaId: "1DB6FAE7-8598-4673-83A9-7A838BB207C5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn\\/2_hf_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6269D1CC-FF57-409F-8284-C95FF4DCEF25", versionEndExcluding: "4.2.2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn\\/2_hf:-:*:*:*:*:*:*:*", matchCriteriaId: "2CBAACFE-CD21-4FAC-9262-1A7F325D6E40", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn\\/3_hf_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "3FA7253F-17B9-411B-B4C9-FE51DF0DE44D", versionEndExcluding: "4.2.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn\\/3_hf:-:*:*:*:*:*:*:*", matchCriteriaId: "DCCAFEF7-CA0C-4F20-B98E-DBB8365F1CCF", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "3EE0B998-E408-408F-8F78-5E90F74E9C9B", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*", matchCriteriaId: "0259EAE9-0CA0-49A5-A573-8339604A181B", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "D054139B-BE36-4B34-88AE-BC487DCB1DCB", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*", matchCriteriaId: "3F0CE2EC-9A73-4576-A389-A19893D47B0F", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "5F14E991-8DF6-4221-A9BF-E13EEF211220", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "B531FDD4-2796-4FE9-9F94-E9D461C7C528", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "CE84D161-BA23-422A-8959-CF047834A631", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E6230347-9AAE-424F-A46F-4A714BA0823D", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "D63658BB-2364-4DE5-904B-2367B70294AC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4A1A44BC-15CC-4CC1-A9D0-4B04233B80CE", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "DFDC8157-7EA3-4BC4-82C1-06A307996F45", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "54EFA8B5-8DA1-4547-9E15-BDC265C56006", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "B1CEB200-E38F-4629-9279-5AF065396678", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "87B14F05-4D54-420F-8393-4AB27EF6A7D1", versionEndExcluding: "4.2.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler:-:*:*:*:*:*:*:*", matchCriteriaId: "49FB85F8-7D45-433E-805B-360725F2980C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_profinet_driver_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "05248152-94EB-4978-98A7-B1A393CA1F03", versionEndExcluding: "2.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*", matchCriteriaId: "526493E9-EF74-4836-9A8F-134B625035AA", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1200_cpu_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2BA63AED-84E4-4F92-A4D4-0713E7F65C4A", versionEndExcluding: "4.4.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:*", matchCriteriaId: "F2B63726-10CE-46AB-ADBA-A511E770E162", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4D81B519-6FE9-405C-8BB1-57D14AF531E5", versionEndExcluding: "4.4.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*", matchCriteriaId: "3871C0C9-C65E-4E0B-9CA8-75E60066297F", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "84E0444D-01E0-4F7A-81A0-314C0F7FA623", versionEndExcluding: "4.4.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*", matchCriteriaId: "07849777-92E7-41D2-9128-F8D20DE15391", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B980BB8C-9AFE-45E4-A4D4-AB555B234059", versionEndExcluding: "4.4.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*", matchCriteriaId: "FE17584A-BF7A-48B8-A9CB-477663766C63", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "BD6FB801-AE4C-4EDF-96CC-33A4CD51165A", versionEndExcluding: "2.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*", matchCriteriaId: "01048F7F-9C5B-47C0-AE16-321FCA670F3D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1500s_cpu_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "D5DE5B3D-13B1-4684-8859-C3FB34FE50CF", versionEndExcluding: "2.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1500s_cpu:-:*:*:*:*:*:*:*", matchCriteriaId: "B82EADBC-AECE-45B4-AF95-6F0D84966E67", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1500t_cpu_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "EF5E4914-A5EA-451C-9FAF-751B74B8BC69", versionEndExcluding: "2.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1500t_cpu:-:*:*:*:*:*:*:*", matchCriteriaId: "4BE2F683-2A24-4152-9A07-00B0117C5F12", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7B6777DC-80B5-4B36-B9AA-DA764C8016F7", versionEndExcluding: "2.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*", matchCriteriaId: "BE0BA68C-EB57-49CE-94A8-E7905AB79824", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "55490E3D-616D-4D21-BAC2-29A51CB067E9", versionEndExcluding: "2.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*", matchCriteriaId: "822894D4-96D5-4BDC-A698-D31262BCF422", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "45303F50-046B-4621-AC6D-2B6E17D948C3", versionEndExcluding: "2.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*", matchCriteriaId: "D2E24A4C-AC13-4382-BDF6-E13878FED4DC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "C87674A8-B518-4910-B03D-FFF4D5A7B627", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*", matchCriteriaId: "602FB384-0DB2-488C-B3CC-96E3A2882976", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_cpu_312_ifm_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7B0C6327-7BF6-4B96-82A8-D750007869EE", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300_cpu_312_ifm:-:*:*:*:*:*:*:*", matchCriteriaId: "CCFCAA2B-71FE-4DB4-B8B0-F5FD1254C331", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_cpu_313_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "3EF9F3FB-FBBA-42A8-9A90-FE34703274B5", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300_cpu_313:-:*:*:*:*:*:*:*", matchCriteriaId: "4E6E900F-63C1-4E50-9DCD-26CE760E5275", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8F2F0659-CD37-4AA9-B7D5-44639515533C", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*", matchCriteriaId: "78399465-EED5-4EBD-A2E1-6FE0BD01EDB4", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_ifm_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "07AD63B6-B05C-4BBF-812D-379C4D8F8CC7", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300_cpu_314_ifm:-:*:*:*:*:*:*:*", matchCriteriaId: "8BE7963C-7AFF-495B-9F0B-28FB393443FD", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_cpu_315_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7F2A0C75-E360-4E3D-85DA-878E39054E26", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300_cpu_315:-:*:*:*:*:*:*:*", matchCriteriaId: "E3962681-E32E-4BD1-8C71-8768248691D4", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "488F0774-43DA-455D-905C-C514A0192260", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*", matchCriteriaId: "E8FD8E6D-0527-4215-B6F0-5824011433FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_cpu_316-2_dp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "F103C351-99C9-4F7D-B69A-D8A876F57504", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300_cpu_316-2_dp:-:*:*:*:*:*:*:*", matchCriteriaId: "644AD6A8-AEDE-4F1C-92F8-836877A81310", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_cpu_318-2_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "BA99549B-5E95-445A-A95B-1CDA7014686B", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300_cpu_318-2:-:*:*:*:*:*:*:*", matchCriteriaId: "FF58C652-E74D-4B57-A7C5-08D7446863D5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-400_pn_v7_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "1B6B9D8B-D7BA-4D72-97C7-7BBEB49802F7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-400_pn_v7:-:*:*:*:*:*:*:*", matchCriteriaId: "E4F8215E-E737-4CD5-B7D9-57FE4A2A2FE5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-400_dp_v7_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "72F7B870-35A1-4900-8104-1303F291E29A", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-400_dp_v7:-:*:*:*:*:*:*:*", matchCriteriaId: "ABE9F7D2-22C7-4E7C-99C3-4A88CDD2CDB7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-400_v6_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7A4C79A5-96BB-4ADB-B28A-C9C48B195F49", versionEndExcluding: "6.0.9", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-400_v6:-:*:*:*:*:*:*:*", matchCriteriaId: "A6445275-2AEF-4285-BE7A-67F20182481C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "EE93A33C-7007-4908-868A-4FBE4D073E57", versionEndExcluding: "6.0.9", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*", matchCriteriaId: "1D082EB6-3C13-40C1-9949-179DC59037C1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "63EA1886-A72E-48A7-B99F-C236BF6992FA", versionEndExcluding: "8.2.2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*", matchCriteriaId: "926D9DCF-A7EA-416A-9A07-122D1FCA027B", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "9D03BD73-51ED-42E0-A552-C32BB7A935B2", versionEndExcluding: "2010", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:2010:-:*:*:*:*:*:*", matchCriteriaId: "7151A19C-0AE5-4F66-9E3D-8BF675A8430C", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\)_2010:-:*:*:*:*:*:*:*", matchCriteriaId: "E6034789-ABD1-4035-8378-F0BA7157B087", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "84B1F9B1-4248-4A4C-A8BB-77475A0E9B9B", versionEndExcluding: "1.5", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.5:-:*:*:*:*:*:*", matchCriteriaId: "F2F99FFB-C312-4080-9580-84AFB7C9FA09", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*", matchCriteriaId: "A1A43D34-ECA3-4330-B85F-02BDD1D22149", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "83803F1C-4842-43BB-B903-C2E91FF7DC08", versionEndExcluding: "1.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*", matchCriteriaId: "B75F50CA-7371-4BC7-8D8A-13F8BC69E4EB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "775C90BB-C026-435C-889A-517EF85656C5", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "CAA92AC6-7DA0-418D-A13F-69268DFD7966", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*", matchCriteriaId: "D61D3E9C-1346-4354-BCD9-B02F67500C41", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_g120_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B1DBCA1A-27F3-4E9A-9F89-65E82A68DE4A", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_g120_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "94CB2F3E-AAA1-4472-BFD4-4E6E1B663FF5", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*", matchCriteriaId: "61A60DCE-384B-43A4-A669-973FB8ECA932", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "856768D2-C096-4CA7-B26F-E94B005C0D79", versionEndExcluding: "5.2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_g130_firmware:5.2:-:*:*:*:*:*:*", matchCriteriaId: "AD0515D7-829B-4591-95D9-94C3982FD727", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*", matchCriteriaId: "373DBE44-AC28-4D04-93BB-35CD8C60E899", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "C579C2C7-0402-46B2-A770-C3B7F71D1096", versionEndExcluding: "5.2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_g150_firmware:5.2:-:*:*:*:*:*:*", matchCriteriaId: "255A153A-A6A0-46A4-A7CF-01D0D09761C7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*", matchCriteriaId: "2296CA65-0E89-4BCB-8003-E7212BF1F585", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "3653DA37-DB23-41E0-8CE8-838E384AA40A", versionEndExcluding: "4.8", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*", matchCriteriaId: "0F86A334-10F9-4DFB-A421-CBCAFD86C8C2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", matchCriteriaId: "DED7F33B-D475-4232-8683-48554A6729F7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0E25804D-D943-4C2A-9C78-AAC61F7BA4FF", versionEndExcluding: "4.8", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.8:-:*:*:*:*:*:*", matchCriteriaId: "06B69CD4-3AEC-4014-81DB-33805A44A5D3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", matchCriteriaId: "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_s110_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "243FFEA3-7193-45EA-B865-E9CA1D6656FE", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*", matchCriteriaId: "6218802E-D3B1-4197-A6B5-7343A50F7D88", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "03F9CBC3-B2B3-4FA7-963D-A8F3AE6D8EA0", versionEndExcluding: "5.2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:-:*:*:*:*:*:*", matchCriteriaId: "6622AE2E-81B0-419C-8C37-A7C56FB92745", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*", matchCriteriaId: "E5A824BD-935F-4E53-8313-C5544B0489C7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6BF989EE-CD8D-450D-90F6-FD15F00B59B9", versionEndExcluding: "5.2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s150_firmware:5.2:-:*:*:*:*:*:*", matchCriteriaId: "EFFDE2CB-684D-4ECE-A104-F355254A46B9", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*", matchCriteriaId: "0D48682C-A39D-4A09-B904-50FA64A9D2A5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "30E52510-9306-42B8-A517-A6BBD34B8B9D", versionEndExcluding: "4.7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.7:-:*:*:*:*:*:*", matchCriteriaId: "58A71910-E54F-426B-BAB1-260AEFD8EF6E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", matchCriteriaId: "C6619B0F-7CDC-40A6-89B2-C6067AF45214", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sm120_firmware:-:*:*:*:*:*:*:*", matchCriteriaId: "28DB0BC6-E60A-4798-80DC-125EF25B3A40", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", matchCriteriaId: "444DD77F-DB65-4766-A89D-7A679B4CA1E1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:sinumerik_828d:*:*:*:*:*:*:*:*", matchCriteriaId: "328F0192-B34D-481C-8964-226317439966", versionEndExcluding: "4.8", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:sinumerik_828d:4.8:-:*:*:*:*:*:*", matchCriteriaId: "C7936CF6-DC07-4550-9FEC-823A2F49096D", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp1:*:*:*:*:*:*", matchCriteriaId: "BEE7D914-F2DE-4D8C-BFB2-7AD16650CD3F", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp2:*:*:*:*:*:*", matchCriteriaId: "BDBAEDBC-6A76-495D-9BC7-BA687F32EE40", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp3:*:*:*:*:*:*", matchCriteriaId: "45EF769B-1EB1-4D2D-84C5-8005EF1EE1EF", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp4:*:*:*:*:*:*", matchCriteriaId: "48EE5859-5450-4078-94E7-E525B999A837", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:sinumerik_840d_sl:*:*:*:*:*:*:*:*", matchCriteriaId: "9FFC86D6-F312-4097-91A6-79C78502323F", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, ], cveTags: [], descriptions: [ { lang: "en", value: "Affected devices improperly handle large amounts of specially crafted UDP packets.\r\n\r\nThis could allow an unauthenticated remote attacker to trigger a denial of service condition.", }, { lang: "es", value: "Se ha identificado una vulnerabilidad en Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Kits de desarrollo/evaluación para PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. variantes SIPLUS), SIMATIC ET200AL, SIMATIC ET200M (incl. variantes SIPLUS), SIMATIC ET200MP IM155-5 PN BA (incl. variantes SIPLUS), SIMATIC ET200MP IM155-5 PN HF (incl. variantes SIPLUS), SIMATIC ET200MP IM155-5 PN ST (incl. variantes SIPLUS) SIPLUS), SIMATIC ET200S (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN BA (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HA (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HS (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN ST (incl. variantes SIPLUS). SIPLUS), SIMATIC ET200SP IM155-6 PN/2 HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN/3 HF (incl. variantes SIPLUS) variantes SIPLUS), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200pro, paneles exteriores SIMATIC HMI Comfort de 7\" y 15\" (incl. variantes SIPLUS), paneles SIMATIC HMI Comfort de 4\" a 22\" (incl. variantes SIPLUS), paneles móviles SIMATIC HMI KTP, acoplador SIMATIC PN/PN (incl. variantes SIPLUS NET), driver SIMATIC PROFINET, familia de CPUs SIMATIC S7-1200 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-1500 (incl. variantes SIPLUS). CPUs ET200 y variantes SIPLUS), SIMATIC S7-1500 Software Controller, familia de CPUs SIMATIC S7-300 (incl. CPUs ET200 y variantes SIPLUS), familia de CPUs SIMATIC S7-400 H V6 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V6 e inferiores (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V7 (incl. variantes SIPLUS), SIMATIC S7-400 PN/DP V7 (incl. variantes SIPLUS). SIPLUS), familia de CPU SIMATIC S7-410 V8 (incl. variantes SIPLUS), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4. 7 PN Control Unit, SINAMICS G120 V4.7 PN Control Unit (incl. variantes SIPLUS), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4. 7, SINAMICS GL150 V4.7, SINAMICS GM150 V4.7, SINAMICS S110, SINAMICS S120 V4.7 (incluidas las variantes SIPLUS), SINAMICS S150, SINAMICS SL150 V4.7, SINAMICS SM120 V4.7, SINUMERIK 828D, SINUMERIK 840D sl. Los dispositivos afectados contienen una vulnerabilidad que permite a un atacante no autenticado desencadenar una condición de denegación de servicio. La vulnerabilidad puede activarse si se envía al dispositivo una gran cantidad de paquetes UDP especialmente diseñados. La vulnerabilidad de seguridad podría ser explotada por un atacante con acceso a la red de los sistemas afectados. La explotación exitosa no requiere privilegios del sistema ni interacción del usuario. Un atacante podría utilizar la vulnerabilidad para comprometer la disponibilidad del dispositivo. En el momento de la publicación del aviso no se conocía ninguna explotación pública de esta vulnerabilidad de seguridad", }, ], id: "CVE-2019-10936", lastModified: "2024-11-21T04:20:11.257", metrics: { cvssMetricV2: [ { acInsufInfo: false, baseSeverity: "MEDIUM", cvssData: { accessComplexity: "LOW", accessVector: "NETWORK", authentication: "NONE", availabilityImpact: "PARTIAL", baseScore: 5, confidentialityImpact: "NONE", integrityImpact: "NONE", vectorString: "AV:N/AC:L/Au:N/C:N/I:N/A:P", version: "2.0", }, exploitabilityScore: 10, impactScore: 2.9, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: false, }, ], cvssMetricV31: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "productcert@siemens.com", type: "Secondary", }, { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "nvd@nist.gov", type: "Secondary", }, ], }, published: "2019-10-10T14:15:14.707", references: [ { source: "productcert@siemens.com", url: "https://cert-portal.siemens.com/productcert/html/ssa-473245.html", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "https://cert-portal.siemens.com/productcert/html/ssa-473245.html", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-400", }, ], source: "productcert@siemens.com", type: "Primary", }, { description: [ { lang: "en", value: "CWE-400", }, ], source: "nvd@nist.gov", type: "Secondary", }, ], }