cve-2019-10923
Vulnerability from cvelistv5
Published
2019-10-10 13:49
Modified
2024-09-10 09:33
Severity ?
EPSS score ?
Summary
An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T22:40:15.265Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.1 Patch 05" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5.0 Patch 01" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200M (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-3 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-4 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN: IO-Link Master", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200S (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 412-2 PN V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.5 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP10 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP10 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF29" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF34" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF33" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP5" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP5" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:33:22.534Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-349422.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-10923", "datePublished": "2019-10-10T13:49:24", "dateReserved": "2019-04-08T00:00:00", "dateUpdated": "2024-09-10T09:33:22.534Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-10923\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2019-10-10T14:15:14.503\",\"lastModified\":\"2024-09-10T10:15:03.397\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Development/Evaluation Kits para PROFINET IO: DK Standard Ethernet Controller (Todas las versiones anteriores a la versi\u00f3n V4.1.1 Patch 05), Development/Evaluation Kits para PROFINET IO: EK-ERTEC 200 (Todas las versiones anteriores a la versi\u00f3n V4.5.0 Patch 01), Development/Evaluation Kits para PROFINET IO: EK-ERTEC 200P (Todas las versiones anteriores a la versi\u00f3n V4.5.0), familia de switches SCALANCE X-200IRT (incluidas las variantes SIPLUS NET) (Todas las versiones anteriores a la versi\u00f3n V5.2.1), SIMATIC ET200M (incluidas las variantes SIPLUS) (Todas las versiones), SIMATIC ET200S (incluidas las variantes SIPLUS) (Todas las versiones), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 4AO U/I 4xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 (Todas las versiones), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 (Todas las versiones), SIMATIC ET200ecoPN: IO-Link Master (Todas las versiones), SIMATIC ET200pro (Todas las versiones), SIMATIC NET CP 1604 (Todas las versiones anteriores a la versi\u00f3n V2.8), SIMATIC NET CP 1616 (Todas las versiones anteriores a la versi\u00f3n V2.8), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incluida la variante SIPLUS NET) (Todas las versiones), familia SIMATIC S7-300 CPU (incluyendo las variantes relacionadas ET200 CPUs y SIPLUS) (Todas las versiones anteriores a la versi\u00f3n V3.X.17), familia SIMATIC S7-400 PN/DP V6 y anteriores CPU (incluidas las variantes SIPLUS) (Todas las versiones), familia SIMATIC S7-400 PN/DP V7 CPU (incluidas las variantes SIPLUS) (Todas las versiones), SIMATIC WinAC RTX (F) 2010 (Todas las versiones anteriores a la versi\u00f3n SIMATIC WinAC RTX 2010 SP3), SIMOTION (incluidas las variantes SIPLUS) (Todas las versiones), SINAMICS DCM (Todas las versiones anteriores a la versi\u00f3n V1.5 HF1), SINAMICS DCP (Todas las versiones anteriores a la versi\u00f3n V1.3), SINAMICS G110M V4.7 Control Unit (Todas las versiones anteriores a la versi\u00f3n V4.7 SP10 HF5), SINAMICS G120 V4.7 Control Unit (incluidas las variantes SIPLUS) (Todas las versiones anteriores a la versi\u00f3n V4.7 SP10 HF5), SINAMICS G130 V4.7 Control Unit (Todas las versiones anteriores a la versi\u00f3n V4.7 HF29), SINAMICS G150 Control Unit (Todas las versiones anteriores a la versi\u00f3n V4.8), SINAMICS GH150 V4.7 Control Unit (Todas las versiones), SINAMICS GL150 V4.7 Control Unit (Todas las versiones), SINAMICS GM150 V4.7 Control Unit (Todas las versiones), SINAMICS S110 Control Unit (Todas las versiones), SINAMICS S120 V4.7 Control Unit and CBE20 (incluidas las variantes SIPLUS) (Todas las versiones anteriores a la versi\u00f3n V4.7 HF34), SINAMICS S150 Control Unit (Todas las versiones anteriores a la versi\u00f3n V4.8), SINAMICS SL150 V4.7 Control Unit (Todas las versiones anteriores a la versi\u00f3n V4.7 HF33), SINAMICS SM120 V4.7 Control Unit (Todas las versiones), SINUMERIK 828D (Todas las versiones anteriores a la versi\u00f3n V4.8 SP5), SINUMERIK 840D sl (Todas las versiones). Un atacante con acceso de red a un producto afectado puede causar una condici\u00f3n de denegaci\u00f3n de servicio al romper la sincronizaci\u00f3n en tiempo real (IRT) de la instalaci\u00f3n afectada. La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante no autenticado con acceso de red a la instalaci\u00f3n afectada. No se requiere interacci\u00f3n del usuario para explotar esta vulnerabilidad de seguridad. La vulnerabilidad afecta la disponibilidad de las instalaciones afectadas\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":5.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:cp1604:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6222006F-09D7-49F7-B8C7-4D94298A8F6A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:cp1604_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.8\",\"matchCriteriaId\":\"1D00494F-8BC7-44C1-816E-0266920F8659\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:cp1616:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"184365A2-BAD2-4926-ACEE-F71E018D3CE5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:cp1616_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.8\",\"matchCriteriaId\":\"0B1E2552-2661-40FB-A88A-4383064A58F3\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"53DF35F1-94FF-4D0B-9FA2-E8B0AFAEA5FF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.1\",\"matchCriteriaId\":\"0FE40195-DE5A-4B9C-9455-FAF92FF090D0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"9B339839-3D74-4E13-9EB6-24CA46F991A5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:p4:*:*:*:*:*:*\",\"matchCriteriaId\":\"92416826-BD34-4611-A5FE-F315C9E8727F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:ek-ertec_200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B47CF3BB-08E4-4B86-B793-8253C172D846\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:ek-ertec_200_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0\",\"matchCriteriaId\":\"191FC7FB-791D-44E9-99C8-6CE15C99D057\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:ek-ertec_200_firmware:4.5.0:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"F894A35F-CB1A-4653-9157-DBCE16247D09\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FB75CD44-5223-40A7-A835-111BF3C25D23\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0\",\"matchCriteriaId\":\"D2859C30-0E12-437E-A07A-7B25D841CFDE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x-200irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"94C7BE35-D3A6-488C-BB3D-D17D65DF4B80\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x-200irt_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.1\",\"matchCriteriaId\":\"4E299AC3-800C-4C27-956A-C7B8DF5F00D0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7037E46B-4FE5-4693-B6A6-B5AF7B652C4F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"14E56570-5C20-40BD-BF0B-F6ED06AFC8F7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A1EC40E7-F004-446C-B5C9-0AB9911105E0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BB063929-AAB0-4FF8-BCA3-71BA80517B1A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3EE0B998-E408-408F-8F78-5E90F74E9C9B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0259EAE9-0CA0-49A5-A573-8339604A181B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_pn\\\\/pn_coupler_6es7158-3ad01-0xa0_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"17C73DE7-4462-4C7B-8475-D5E6075C8E00\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_pn\\\\/pn_coupler_6es7158-3ad01-0xa0:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2155DBBF-98F3-42A2-8DB1-0BB27984D0E0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3.17\",\"matchCriteriaId\":\"C87674A8-B518-4910-B03D-FFF4D5A7B627\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"602FB384-0DB2-488C-B3CC-96E3A2882976\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-300_cpu_312_ifm_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3.17\",\"matchCriteriaId\":\"7B0C6327-7BF6-4B96-82A8-D750007869EE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_312_ifm:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CCFCAA2B-71FE-4DB4-B8B0-F5FD1254C331\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-300_cpu_313_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3.17\",\"matchCriteriaId\":\"3EF9F3FB-FBBA-42A8-9A90-FE34703274B5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_313:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4E6E900F-63C1-4E50-9DCD-26CE760E5275\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3.17\",\"matchCriteriaId\":\"8F2F0659-CD37-4AA9-B7D5-44639515533C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"78399465-EED5-4EBD-A2E1-6FE0BD01EDB4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-300_cpu_314_ifm_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3.17\",\"matchCriteriaId\":\"07AD63B6-B05C-4BBF-812D-379C4D8F8CC7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_314_ifm:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8BE7963C-7AFF-495B-9F0B-28FB393443FD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-300_cpu_315_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3.17\",\"matchCriteriaId\":\"7F2A0C75-E360-4E3D-85DA-878E39054E26\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_315:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E3962681-E32E-4BD1-8C71-8768248691D4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3.17\",\"matchCriteriaId\":\"488F0774-43DA-455D-905C-C514A0192260\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E8FD8E6D-0527-4215-B6F0-5824011433FB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-300_cpu_316-2_dp_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3.17\",\"matchCriteriaId\":\"F103C351-99C9-4F7D-B69A-D8A876F57504\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_316-2_dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"644AD6A8-AEDE-4F1C-92F8-836877A81310\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-300_cpu_318-2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3.17\",\"matchCriteriaId\":\"BA99549B-5E95-445A-A95B-1CDA7014686B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_318-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FF58C652-E74D-4B57-A7C5-08D7446863D5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-400_v6_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C7B2893A-F0B4-4795-AF1C-DFF17D493929\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_v6:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A6445275-2AEF-4285-BE7A-67F20182481C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-400_pn_v7_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1B6B9D8B-D7BA-4D72-97C7-7BBEB49802F7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_pn_v7:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E4F8215E-E737-4CD5-B7D9-57FE4A2A2FE5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-400_dp_v7_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"72F7B870-35A1-4900-8104-1303F291E29A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_dp_v7:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"ABE9F7D2-22C7-4E7C-99C3-4A88CDD2CDB7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_winac_rtx_\\\\(f\\\\)_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2010\",\"matchCriteriaId\":\"9D03BD73-51ED-42E0-A552-C32BB7A935B2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_winac_rtx_\\\\(f\\\\)_firmware:2010:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"7151A19C-0AE5-4F66-9E3D-8BF675A8430C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_winac_rtx_\\\\(f\\\\)_firmware:2010:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"BEEB72F4-AE57-49DD-8876-1BCA7B805692\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_winac_rtx_\\\\(f\\\\)_firmware:2010:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"7929F123-AC76-4F49-940F-558CABC25E75\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_winac_rtx_\\\\(f\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C6143A7A-9D01-4D13-B0F5-2AD0DD6DA5EE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"080E9ADC-C88F-45D4-8453-6E5E25371476\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"879CF09E-4735-4A73-8E7B-215F2701F7E0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.5\",\"matchCriteriaId\":\"84B1F9B1-4248-4A4C-A8BB-77475A0E9B9B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_dcm_firmware:1.5:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"F2F99FFB-C312-4080-9580-84AFB7C9FA09\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A1A43D34-ECA3-4330-B85F-02BDD1D22149\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.3\",\"matchCriteriaId\":\"83803F1C-4842-43BB-B903-C2E91FF7DC08\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B75F50CA-7371-4BC7-8D8A-13F8BC69E4EB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.7\",\"matchCriteriaId\":\"775C90BB-C026-435C-889A-517EF85656C5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"CAA92AC6-7DA0-418D-A13F-69268DFD7966\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D61D3E9C-1346-4354-BCD9-B02F67500C41\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_g120_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.7\",\"matchCriteriaId\":\"B1DBCA1A-27F3-4E9A-9F89-65E82A68DE4A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_g120_firmware:4.7:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"94CB2F3E-AAA1-4472-BFD4-4E6E1B663FF5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"61A60DCE-384B-43A4-A669-973FB8ECA932\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.7\",\"matchCriteriaId\":\"4B3B0706-47CD-43FB-8E3A-7EEEF020AFBA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"1D36CF8D-6DA4-49ED-9EF1-F96292F671EE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"373DBE44-AC28-4D04-93BB-35CD8C60E899\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.8\",\"matchCriteriaId\":\"07F8091F-C17A-4913-A1BC-A7BA376B595F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2296CA65-0E89-4BCB-8003-E7212BF1F585\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.8\",\"matchCriteriaId\":\"6E231DE7-8B8D-41A3-A163-CE8EF50AF9D0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_gh150_firmware:4.8:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"6D076504-AFE3-4C51-80E5-C5992CA7D511\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BF977545-395A-4C34-BB22-A1047B5B6E85\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.8\",\"matchCriteriaId\":\"3653DA37-DB23-41E0-8CE8-838E384AA40A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"0F86A334-10F9-4DFB-A421-CBCAFD86C8C2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DED7F33B-D475-4232-8683-48554A6729F7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.8\",\"matchCriteriaId\":\"0E25804D-D943-4C2A-9C78-AAC61F7BA4FF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_gm150_firmware:4.8:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"06B69CD4-3AEC-4014-81DB-33805A44A5D3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s110_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"243FFEA3-7193-45EA-B865-E9CA1D6656FE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6218802E-D3B1-4197-A6B5-7343A50F7D88\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.7\",\"matchCriteriaId\":\"77A0BE57-1A9A-4564-9C53-CF47DEEF7991\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"376556D0-1AE2-4F80-B3CE-C0251E35C326\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E5A824BD-935F-4E53-8313-C5544B0489C7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.8\",\"matchCriteriaId\":\"22AFC8AE-8AF0-4418-B251-4CE293B9DCD8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0D48682C-A39D-4A09-B904-50FA64A9D2A5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.7\",\"matchCriteriaId\":\"30E52510-9306-42B8-A517-A6BBD34B8B9D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_sl150_firmware:4.7:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"58A71910-E54F-426B-BAB1-260AEFD8EF6E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C6619B0F-7CDC-40A6-89B2-C6067AF45214\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CFFE3048-EEB0-48A0-BED0-8647284B022B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"444DD77F-DB65-4766-A89D-7A679B4CA1E1\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinumerik_828d:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.8\",\"matchCriteriaId\":\"328F0192-B34D-481C-8964-226317439966\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinumerik_828d:4.8:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"C7936CF6-DC07-4550-9FEC-823A2F49096D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinumerik_828d:4.8:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"BEE7D914-F2DE-4D8C-BFB2-7AD16650CD3F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinumerik_828d:4.8:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"BDBAEDBC-6A76-495D-9BC7-BA687F32EE40\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinumerik_828d:4.8:sp3:*:*:*:*:*:*\",\"matchCriteriaId\":\"45EF769B-1EB1-4D2D-84C5-8005EF1EE1EF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinumerik_828d:4.8:sp4:*:*:*:*:*:*\",\"matchCriteriaId\":\"48EE5859-5450-4078-94E7-E525B999A837\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinumerik_840d_sl:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9FFC86D6-F312-4097-91A6-79C78502323F\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-349422.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.