All the vulnerabilites related to siemens - sinumerik_integrate_runmyhmi_\/automotive
Vulnerability from fkie_nvd
Published
2023-12-12 12:15
Modified
2024-11-21 08:28
Severity ?
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9D89CD-FDA5-42F0-8161-3752C8AED7F3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "96D49ACA-BF2E-4C89-8168-E4A95D5B22AA", "versionEndExcluding": "4.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\\/automotive:-:*:*:*:*:*:*:*", "matchCriteriaId": "D882C3C8-EFE7-4DB6-B3E7-6152D7FEB74C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "29E53F22-9086-40A2-85E0-20B58EC1E4BB", "versionEndExcluding": "15", "versionStartIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F86DBB7-A5C7-43C4-8B64-0B67C90B79A8", "versionEndExcluding": "16", "versionStartIncluding": "15", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0BCF747-13ED-4AE7-9BE7-37858573AF27", "versionEndExcluding": "17", "versionStartIncluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "C83587B9-53E2-4B2F-9FE4-5DDD232571F6", "versionEndExcluding": "18", "versionStartIncluding": "17", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*", "matchCriteriaId": "085B0B91-40DE-4328-A28C-1C920A6440D1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*", "matchCriteriaId": "68C7D9A3-9304-4A81-A970-717E5BA1ECF1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*", "matchCriteriaId": "6A09C712-871D-4A81-A630-33BC5DF49FE5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en:\nOpcenter Quality (todas las versiones), \nSIMATIC PCS neo (todas las versiones \u0026lt; V4.1), \nSINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones " } ], "id": "CVE-2023-46285", "lastModified": "2024-11-21T08:28:13.877", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Primary" } ] }, "published": "2023-12-12T12:15:14.477", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-12-12 12:15
Modified
2024-11-21 08:28
Severity ?
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9D89CD-FDA5-42F0-8161-3752C8AED7F3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "96D49ACA-BF2E-4C89-8168-E4A95D5B22AA", "versionEndExcluding": "4.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\\/automotive:-:*:*:*:*:*:*:*", "matchCriteriaId": "D882C3C8-EFE7-4DB6-B3E7-6152D7FEB74C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "29E53F22-9086-40A2-85E0-20B58EC1E4BB", "versionEndExcluding": "15", "versionStartIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F86DBB7-A5C7-43C4-8B64-0B67C90B79A8", "versionEndExcluding": "16", "versionStartIncluding": "15", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0BCF747-13ED-4AE7-9BE7-37858573AF27", "versionEndExcluding": "17", "versionStartIncluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "C83587B9-53E2-4B2F-9FE4-5DDD232571F6", "versionEndExcluding": "18", "versionStartIncluding": "17", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*", "matchCriteriaId": "085B0B91-40DE-4328-A28C-1C920A6440D1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*", "matchCriteriaId": "68C7D9A3-9304-4A81-A970-717E5BA1ECF1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*", "matchCriteriaId": "6A09C712-871D-4A81-A630-33BC5DF49FE5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en:\nOpcenter Quality (todas las versiones), \nSIMATIC PCS neo (todas las versiones \u0026lt; V4.1), \nSINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones " } ], "id": "CVE-2023-46283", "lastModified": "2024-11-21T08:28:13.617", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Primary" } ] }, "published": "2023-12-12T12:15:14.067", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-12-12 12:15
Modified
2024-11-21 08:28
Severity ?
7.1 (High) - CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L
6.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
6.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9D89CD-FDA5-42F0-8161-3752C8AED7F3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "96D49ACA-BF2E-4C89-8168-E4A95D5B22AA", "versionEndExcluding": "4.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\\/automotive:-:*:*:*:*:*:*:*", "matchCriteriaId": "D882C3C8-EFE7-4DB6-B3E7-6152D7FEB74C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "29E53F22-9086-40A2-85E0-20B58EC1E4BB", "versionEndExcluding": "15", "versionStartIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F86DBB7-A5C7-43C4-8B64-0B67C90B79A8", "versionEndExcluding": "16", "versionStartIncluding": "15", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0BCF747-13ED-4AE7-9BE7-37858573AF27", "versionEndExcluding": "17", "versionStartIncluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "C83587B9-53E2-4B2F-9FE4-5DDD232571F6", "versionEndExcluding": "18", "versionStartIncluding": "17", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*", "matchCriteriaId": "085B0B91-40DE-4328-A28C-1C920A6440D1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*", "matchCriteriaId": "68C7D9A3-9304-4A81-A970-717E5BA1ECF1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*", "matchCriteriaId": "6A09C712-871D-4A81-A630-33BC5DF49FE5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en:\nOpcenter Quality (todas las versiones), \nSIMATIC PCS neo (todas las versiones \u0026lt; V4.1), \nSINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones " } ], "id": "CVE-2023-46282", "lastModified": "2024-11-21T08:28:13.473", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 1.6, "impactScore": 5.5, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-12-12T12:15:13.870", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-12-12 12:15
Modified
2024-11-21 08:28
Severity ?
7.1 (High) - CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9D89CD-FDA5-42F0-8161-3752C8AED7F3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "96D49ACA-BF2E-4C89-8168-E4A95D5B22AA", "versionEndExcluding": "4.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\\/automotive:-:*:*:*:*:*:*:*", "matchCriteriaId": "D882C3C8-EFE7-4DB6-B3E7-6152D7FEB74C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "29E53F22-9086-40A2-85E0-20B58EC1E4BB", "versionEndExcluding": "15", "versionStartIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F86DBB7-A5C7-43C4-8B64-0B67C90B79A8", "versionEndExcluding": "16", "versionStartIncluding": "15", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0BCF747-13ED-4AE7-9BE7-37858573AF27", "versionEndExcluding": "17", "versionStartIncluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "C83587B9-53E2-4B2F-9FE4-5DDD232571F6", "versionEndExcluding": "18", "versionStartIncluding": "17", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*", "matchCriteriaId": "085B0B91-40DE-4328-A28C-1C920A6440D1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*", "matchCriteriaId": "68C7D9A3-9304-4A81-A970-717E5BA1ECF1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*", "matchCriteriaId": "6A09C712-871D-4A81-A630-33BC5DF49FE5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en:\nOpcenter Quality (todas las versiones), \nSIMATIC PCS neo (todas las versiones \u0026lt; V4.1), \nSINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones " } ], "id": "CVE-2023-46281", "lastModified": "2024-11-21T08:28:13.317", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 1.6, "impactScore": 5.5, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-12-12T12:15:13.653", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-942" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-12-12 12:15
Modified
2024-11-21 08:28
Severity ?
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9D89CD-FDA5-42F0-8161-3752C8AED7F3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "96D49ACA-BF2E-4C89-8168-E4A95D5B22AA", "versionEndExcluding": "4.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\\/automotive:-:*:*:*:*:*:*:*", "matchCriteriaId": "D882C3C8-EFE7-4DB6-B3E7-6152D7FEB74C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "29E53F22-9086-40A2-85E0-20B58EC1E4BB", "versionEndExcluding": "15", "versionStartIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F86DBB7-A5C7-43C4-8B64-0B67C90B79A8", "versionEndExcluding": "16", "versionStartIncluding": "15", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0BCF747-13ED-4AE7-9BE7-37858573AF27", "versionEndExcluding": "17", "versionStartIncluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "C83587B9-53E2-4B2F-9FE4-5DDD232571F6", "versionEndExcluding": "18", "versionStartIncluding": "17", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*", "matchCriteriaId": "085B0B91-40DE-4328-A28C-1C920A6440D1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*", "matchCriteriaId": "68C7D9A3-9304-4A81-A970-717E5BA1ECF1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*", "matchCriteriaId": "6A09C712-871D-4A81-A630-33BC5DF49FE5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en:\nOpcenter Quality (todas las versiones), \nSIMATIC PCS neo (todas las versiones \u0026lt; V4.1), \nSINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones " } ], "id": "CVE-2023-46284", "lastModified": "2024-11-21T08:28:13.760", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Primary" } ] }, "published": "2023-12-12T12:15:14.273", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
cve-2023-46284
Vulnerability from cvelistv5
Published
2023-12-12 11:27
Modified
2025-01-14 10:29
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Opcenter Execution Foundation |
Version: 0 < V2407 |
||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:45:40.702Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "lessThan": "V2407", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "lessThan": "V2312", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V15.1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-14T10:29:54.329Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-46284", "datePublished": "2023-12-12T11:27:15.737Z", "dateReserved": "2023-10-20T10:29:46.260Z", "dateUpdated": "2025-01-14T10:29:54.329Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-46283
Vulnerability from cvelistv5
Published
2023-12-12 11:27
Modified
2025-01-14 10:29
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Opcenter Execution Foundation |
Version: 0 < V2407 |
||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:45:40.675Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "lessThan": "V2407", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "lessThan": "V2312", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V15.1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-14T10:29:52.922Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-46283", "datePublished": "2023-12-12T11:27:14.437Z", "dateReserved": "2023-10-20T10:29:46.260Z", "dateUpdated": "2025-01-14T10:29:52.922Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-46285
Vulnerability from cvelistv5
Published
2023-12-12 11:27
Modified
2025-01-14 10:29
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Opcenter Execution Foundation |
Version: 0 < V2407 |
||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:45:40.610Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "lessThan": "V2407", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "lessThan": "V2312", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V15.1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20: Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-14T10:29:55.697Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-46285", "datePublished": "2023-12-12T11:27:17.080Z", "dateReserved": "2023-10-20T10:29:46.260Z", "dateUpdated": "2025-01-14T10:29:55.697Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-46281
Vulnerability from cvelistv5
Published
2023-12-12 11:27
Modified
2025-01-14 10:29
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Opcenter Execution Foundation |
Version: 0 < V2407 |
||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:37:40.334Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-46281", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-08T14:41:24.487753Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-08T14:41:45.644Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "lessThan": "V2407", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "lessThan": "V2312", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V15.1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-942", "description": "CWE-942: Permissive Cross-domain Policy with Untrusted Domains", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-14T10:29:50.318Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-46281", "datePublished": "2023-12-12T11:27:11.796Z", "dateReserved": "2023-10-20T10:29:46.259Z", "dateUpdated": "2025-01-14T10:29:50.318Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-46282
Vulnerability from cvelistv5
Published
2023-12-12 11:27
Modified
2025-01-14 10:29
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Opcenter Execution Foundation |
Version: 0 < V2407 |
||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:37:40.314Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "lessThan": "V2407", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "lessThan": "V2312", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V15.1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-14T10:29:51.618Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-46282", "datePublished": "2023-12-12T11:27:13.134Z", "dateReserved": "2023-10-20T10:29:46.260Z", "dateUpdated": "2025-01-14T10:29:51.618Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }