CVE-2023-46284 (GCVE-0-2023-46284)

Vulnerability from cvelistv5 – Published: 2023-12-12 11:27 – Updated: 2025-01-14 10:29
VLAI?
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T20:45:40.702Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Opcenter Execution Foundation",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2407",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Opcenter Quality",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS neo",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINEC NMS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0 SP1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Totally Integrated Automation Portal (TIA Portal) V14",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Totally Integrated Automation Portal (TIA Portal) V15.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Totally Integrated Automation Portal (TIA Portal) V16",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Totally Integrated Automation Portal (TIA Portal) V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V17 Update 8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Totally Integrated Automation Portal (TIA Portal) V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V18 Update 3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-14T10:29:54.329Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-46284",
    "datePublished": "2023-12-12T11:27:15.737Z",
    "dateReserved": "2023-10-20T10:29:46.260Z",
    "dateUpdated": "2025-01-14T10:29:54.329Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9D9D89CD-FDA5-42F0-8161-3752C8AED7F3\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1\", \"matchCriteriaId\": \"96D49ACA-BF2E-4C89-8168-E4A95D5B22AA\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\\\\/automotive:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D882C3C8-EFE7-4DB6-B3E7-6152D7FEB74C\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"14.0\", \"versionEndExcluding\": \"15\", \"matchCriteriaId\": \"29E53F22-9086-40A2-85E0-20B58EC1E4BB\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"15\", \"versionEndExcluding\": \"16\", \"matchCriteriaId\": \"3F86DBB7-A5C7-43C4-8B64-0B67C90B79A8\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"16\", \"versionEndExcluding\": \"17\", \"matchCriteriaId\": \"B0BCF747-13ED-4AE7-9BE7-37858573AF27\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"17\", \"versionEndExcluding\": \"18\", \"matchCriteriaId\": \"C83587B9-53E2-4B2F-9FE4-5DDD232571F6\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"085B0B91-40DE-4328-A28C-1C920A6440D1\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"68C7D9A3-9304-4A81-A970-717E5BA1ECF1\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*\", \"matchCriteriaId\": \"6A09C712-871D-4A81-A630-33BC5DF49FE5\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en:\\nOpcenter Quality (todas las versiones), \\nSIMATIC PCS neo (todas las versiones \u0026lt; V4.1), \\nSINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), \\nTotally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), \\nTotally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), \\nTotally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), \\nTotally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), \\nTotally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones \"}]",
      "id": "CVE-2023-46284",
      "lastModified": "2024-11-21T08:28:13.760",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"productcert@siemens.com\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
      "published": "2023-12-12T12:15:14.273",
      "references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-999588.html\", \"source\": \"productcert@siemens.com\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-999588.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-120\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-787\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-46284\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-12-12T12:15:14.273\",\"lastModified\":\"2024-11-21T08:28:13.760\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en:\\nOpcenter Quality (todas las versiones), \\nSIMATIC PCS neo (todas las versiones \u0026lt; V4.1), \\nSINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), \\nTotally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), \\nTotally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), \\nTotally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), \\nTotally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), \\nTotally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones \"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-120\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9D9D89CD-FDA5-42F0-8161-3752C8AED7F3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1\",\"matchCriteriaId\":\"96D49ACA-BF2E-4C89-8168-E4A95D5B22AA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\\\\/automotive:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D882C3C8-EFE7-4DB6-B3E7-6152D7FEB74C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"14.0\",\"versionEndExcluding\":\"15\",\"matchCriteriaId\":\"29E53F22-9086-40A2-85E0-20B58EC1E4BB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"15\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"3F86DBB7-A5C7-43C4-8B64-0B67C90B79A8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndExcluding\":\"17\",\"matchCriteriaId\":\"B0BCF747-13ED-4AE7-9BE7-37858573AF27\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"17\",\"versionEndExcluding\":\"18\",\"matchCriteriaId\":\"C83587B9-53E2-4B2F-9FE4-5DDD232571F6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"085B0B91-40DE-4328-A28C-1C920A6440D1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"68C7D9A3-9304-4A81-A970-717E5BA1ECF1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*\",\"matchCriteriaId\":\"6A09C712-871D-4A81-A630-33BC5DF49FE5\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-999588.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-999588.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…