Search criteria

23 vulnerabilities found for sitemanager by secomea

CVE-2022-38125 (GCVE-0-2022-38125)

Vulnerability from cvelistv5 – Published: 2023-04-19 11:58 – Updated: 2025-02-05 15:00
VLAI?
Title
FTP Agent forwards traffic on inactive ports to LinkManager
Summary
Improper Restriction of Communication Channel to Intended Endpoints vulnerability in Secomea SiteManager (FTP Agent modules) allows Exploiting Trust in Client.
CWE
  • CWE-923 - Improper Restriction of Communication Channel to Intended Endpoints
Assigner
Impacted products
Vendor Product Version
Secomea SiteManager Affected: 5.0 , ≤ 10.0 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:45:52.834Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-38125",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-05T14:59:41.569876Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-923",
                "description": "CWE-923 Improper Restriction of Communication Channel to Intended Endpoints",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T15:00:42.143Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "FTP Agent"
          ],
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThanOrEqual": "10.0",
              "status": "affected",
              "version": "5.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2023-04-19T11:58:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Restriction of Communication Channel to Intended Endpoints vulnerability in Secomea SiteManager (FTP Agent modules) allows Exploiting Trust in Client."
            }
          ],
          "value": "Improper Restriction of Communication Channel to Intended Endpoints vulnerability in Secomea SiteManager (FTP Agent modules) allows Exploiting Trust in Client."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-22",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-22 Exploiting Trust in Client"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 2.9,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:C/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-923",
              "description": "CWE-923 Improper Restriction of Communication Channel to Intended Endpoints",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-19T11:58:14.508Z",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "url": "https://www.secomea.com/support/cybersecurity-advisory/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "FTP Agent forwards traffic on inactive ports to LinkManager",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2022-38125",
    "datePublished": "2023-04-19T11:58:14.508Z",
    "dateReserved": "2022-08-10T09:46:05.634Z",
    "dateUpdated": "2025-02-05T15:00:42.143Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-38124 (GCVE-0-2022-38124)

Vulnerability from cvelistv5 – Published: 2022-12-13 13:06 – Updated: 2025-04-18 15:28
VLAI?
Title
Unwanted debug tool
Summary
Debug tool in Secomea SiteManager allows logged-in administrator to modify system state in an unintended manner.
CWE
  • CWE-267 - Privilege Defined With Unsafe Actions
Assigner
Impacted products
Vendor Product Version
Secomea SiteManager Affected: 0 , ≤ 10.0.622425017 ("custom")
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:45:52.627Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-38124",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:28:06.181233Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-18T15:28:20.215Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThanOrEqual": "10.0.622425017",
              "status": "affected",
              "version": "0",
              "versionType": "\"custom\""
            }
          ]
        }
      ],
      "datePublic": "2022-12-12T23:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Debug tool in Secomea SiteManager allows logged-in administrator to modify system state in an unintended manner."
            }
          ],
          "value": "Debug tool in Secomea SiteManager allows logged-in administrator to modify system state in an unintended manner."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-121",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-121 Exploit Test APIs"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-267",
              "description": "CWE-267 Privilege Defined With Unsafe Actions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-13T13:06:17.021Z",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "url": "https://www.secomea.com/support/cybersecurity-advisory/"
        }
      ],
      "source": {
        "defect": [
          "RD-6294"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Unwanted debug tool",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2022-38124",
    "datePublished": "2022-12-13T13:06:17.021Z",
    "dateReserved": "2022-08-10T09:46:05.634Z",
    "dateUpdated": "2025-04-18T15:28:20.215Z",
    "requesterUserId": "44bd1e71-3702-434c-b36b-c1ac3bb0bab6",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25785 (GCVE-0-2022-25785)

Vulnerability from cvelistv5 – Published: 2022-05-04 13:57 – Updated: 2024-08-03 04:49
VLAI?
Title
Buffer overrun
Summary
Stack-based Buffer Overflow vulnerability in SiteManager allows logged-in or local user to cause arbitrary code execution. This issue affects: Secomea SiteManager all versions prior to 9.7.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Secomea SiteManager Affected: all , < 9.7 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:49:43.219Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.7",
              "status": "affected",
              "version": "all",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based Buffer Overflow vulnerability in SiteManager allows logged-in or local user to cause arbitrary code execution. This issue affects: Secomea SiteManager all versions prior to 9.7."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-04T13:57:06",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secomea.com/support/cybersecurity-advisory/"
        }
      ],
      "source": {
        "defect": [
          "RD-5455"
        ],
        "discovery": "INTERNAL"
      },
      "title": "Buffer overrun",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "VulnerabilityReporting@secomea.com",
          "ID": "CVE-2022-25785",
          "STATE": "PUBLIC",
          "TITLE": "Buffer overrun"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SiteManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "all",
                            "version_value": "9.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Stack-based Buffer Overflow vulnerability in SiteManager allows logged-in or local user to cause arbitrary code execution. This issue affects: Secomea SiteManager all versions prior to 9.7."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121 Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.secomea.com/support/cybersecurity-advisory/",
              "refsource": "MISC",
              "url": "https://www.secomea.com/support/cybersecurity-advisory/"
            }
          ]
        },
        "source": {
          "defect": [
            "RD-5455"
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2022-25785",
    "datePublished": "2022-05-04T13:57:06",
    "dateReserved": "2022-02-22T00:00:00",
    "dateUpdated": "2024-08-03T04:49:43.219Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25784 (GCVE-0-2022-25784)

Vulnerability from cvelistv5 – Published: 2022-05-04 13:56 – Updated: 2024-08-03 04:49
VLAI?
Title
User controllable HTML element attribute (potential XSS)
Summary
Cross-site Scripting (XSS) vulnerability in Web GUI of SiteManager allows logged-in user to inject scripting. This issue affects: Secomea SiteManager all versions prior to 9.7.
CWE
  • CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
Vendor Product Version
Secomea SiteManager Affected: all , < 9.7 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:49:43.564Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.7",
              "status": "affected",
              "version": "all",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Cross-site Scripting (XSS) vulnerability in Web GUI of SiteManager allows logged-in user to inject scripting. This issue affects: Secomea SiteManager all versions prior to 9.7."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross-site Scripting (XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-04T13:56:20",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secomea.com/support/cybersecurity-advisory/"
        }
      ],
      "source": {
        "defect": [
          "RD-5371"
        ],
        "discovery": "INTERNAL"
      },
      "title": "User controllable HTML element attribute (potential XSS)",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "VulnerabilityReporting@secomea.com",
          "ID": "CVE-2022-25784",
          "STATE": "PUBLIC",
          "TITLE": "User controllable HTML element attribute (potential XSS)"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SiteManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "all",
                            "version_value": "9.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cross-site Scripting (XSS) vulnerability in Web GUI of SiteManager allows logged-in user to inject scripting. This issue affects: Secomea SiteManager all versions prior to 9.7."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Cross-site Scripting (XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.secomea.com/support/cybersecurity-advisory/",
              "refsource": "MISC",
              "url": "https://www.secomea.com/support/cybersecurity-advisory/"
            }
          ]
        },
        "source": {
          "defect": [
            "RD-5371"
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2022-25784",
    "datePublished": "2022-05-04T13:56:20",
    "dateReserved": "2022-02-22T00:00:00",
    "dateUpdated": "2024-08-03T04:49:43.564Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-32010 (GCVE-0-2021-32010)

Vulnerability from cvelistv5 – Published: 2022-05-04 13:45 – Updated: 2024-08-03 23:17
VLAI?
Title
Clients may connect to a GateManager with TLS 1.0
Summary
Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7.
CWE
  • CWE-326 - Inadequate Encryption Strength
Assigner
References
Impacted products
Vendor Product Version
Secomea SiteManager Affected: All , < 9.7 (custom)
Create a notification for this product.
    Secomea LinkManager Affected: unspecified , < 9.7 (custom)
Create a notification for this product.
    Secomea GateManager Affected: unspecified , < 9.7 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:17:28.463Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.7",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "LinkManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.7",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "GateManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.7",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-326",
              "description": "CWE-326 Inadequate Encryption Strength",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-04T13:45:03",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secomea.com/support/cybersecurity-advisory/"
        }
      ],
      "source": {
        "defect": [
          "RD-5699"
        ],
        "discovery": "INTERNAL"
      },
      "title": "Clients may connect to a GateManager with TLS 1.0",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "VulnerabilityReporting@secomea.com",
          "ID": "CVE-2021-32010",
          "STATE": "PUBLIC",
          "TITLE": "Clients may connect to a GateManager with TLS 1.0"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SiteManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "9.7"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "LinkManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "9.7"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GateManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "9.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-326 Inadequate Encryption Strength"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.secomea.com/support/cybersecurity-advisory/",
              "refsource": "MISC",
              "url": "https://www.secomea.com/support/cybersecurity-advisory/"
            }
          ]
        },
        "source": {
          "defect": [
            "RD-5699"
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2021-32010",
    "datePublished": "2022-05-04T13:45:03",
    "dateReserved": "2021-05-03T00:00:00",
    "dateUpdated": "2024-08-03T23:17:28.463Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-32005 (GCVE-0-2021-32005)

Vulnerability from cvelistv5 – Published: 2022-03-07 15:21 – Updated: 2024-08-03 23:17
VLAI?
Title
SiteManager Log View XSS Issue
Summary
Cross-site Scripting (XSS) vulnerability in log view of Secomea SiteManager allows a logged in user to store javascript for later execution. This issue affects: Secomea SiteManager Version 9.6.621421014 and all prior versions.
CWE
  • CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
Vendor Product Version
Secomea SiteManager Affected: All , ≤ 9.6.621421014 (custom)
Create a notification for this product.
Credits
Schlumberger
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:17:27.941Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory/#5017"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThanOrEqual": "9.6.621421014",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Schlumberger"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Cross-site Scripting (XSS) vulnerability in log view of Secomea SiteManager allows a logged in user to store javascript for later execution. This issue affects: Secomea SiteManager Version 9.6.621421014 and all prior versions."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross-site Scripting (XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-07T15:21:27",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secomea.com/support/cybersecurity-advisory/#5017"
        }
      ],
      "source": {
        "defect": [
          "RD-5017"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "SiteManager Log View XSS Issue",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "VulnerabilityReporting@secomea.com",
          "ID": "CVE-2021-32005",
          "STATE": "PUBLIC",
          "TITLE": "SiteManager Log View XSS Issue"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SiteManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "9.6.621421014"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Schlumberger"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cross-site Scripting (XSS) vulnerability in log view of Secomea SiteManager allows a logged in user to store javascript for later execution. This issue affects: Secomea SiteManager Version 9.6.621421014 and all prior versions."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Cross-site Scripting (XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.secomea.com/support/cybersecurity-advisory/#5017",
              "refsource": "MISC",
              "url": "https://www.secomea.com/support/cybersecurity-advisory/#5017"
            }
          ]
        },
        "source": {
          "defect": [
            "RD-5017"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2021-32005",
    "datePublished": "2022-03-07T15:21:27",
    "dateReserved": "2021-05-03T00:00:00",
    "dateUpdated": "2024-08-03T23:17:27.941Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-32003 (GCVE-0-2021-32003)

Vulnerability from cvelistv5 – Published: 2021-08-05 20:33 – Updated: 2024-08-03 23:17
VLAI?
Title
Configuration service port remains open 10 minutes after reboot even when already provisioned
Summary
Unprotected Transport of Credentials vulnerability in SiteManager provisioning service allows local attacker to capture credentials if the service is used after provisioning. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware.
CWE
  • CWE-523 - Unprotected Transport of Credentials
Assigner
References
Impacted products
Vendor Product Version
Secomea SiteManager Affected: All , < 9.5 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:17:27.897Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "Hardware"
          ],
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.5",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Unprotected Transport of Credentials vulnerability in SiteManager provisioning service allows local attacker to capture credentials if the service is used after provisioning. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-523",
              "description": "CWE-523 Unprotected Transport of Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-08-05T20:33:30",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secomea.com/support/cybersecurity-advisory"
        }
      ],
      "source": {
        "defect": [
          "RD-3777"
        ],
        "discovery": "INTERNAL"
      },
      "title": "Configuration service port remains open 10 minutes after reboot even when already provisioned",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "VulnerabilityReporting@secomea.com",
          "ID": "CVE-2021-32003",
          "STATE": "PUBLIC",
          "TITLE": "Configuration service port remains open 10 minutes after reboot even when already provisioned"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SiteManager",
                      "version": {
                        "version_data": [
                          {
                            "platform": "Hardware",
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "9.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Unprotected Transport of Credentials vulnerability in SiteManager provisioning service allows local attacker to capture credentials if the service is used after provisioning. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-523 Unprotected Transport of Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.secomea.com/support/cybersecurity-advisory",
              "refsource": "MISC",
              "url": "https://www.secomea.com/support/cybersecurity-advisory"
            }
          ]
        },
        "source": {
          "defect": [
            "RD-3777"
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2021-32003",
    "datePublished": "2021-08-05T20:33:30",
    "dateReserved": "2021-05-03T00:00:00",
    "dateUpdated": "2024-08-03T23:17:27.897Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-32002 (GCVE-0-2021-32002)

Vulnerability from cvelistv5 – Published: 2021-08-05 20:33 – Updated: 2024-08-03 23:17
VLAI?
Title
SiteManager troubleshooter allows access without authentication from local network
Summary
Improper Access Control vulnerability in web service of Secomea SiteManager allows local attacker without credentials to gather network information and configuration of the SiteManager. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware.
CWE
Assigner
References
Impacted products
Vendor Product Version
Secomea SiteManager Affected: All , < 9.5 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:17:27.964Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "Hardware"
          ],
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.5",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper Access Control vulnerability in web service of Secomea SiteManager allows local attacker without credentials to gather network information and configuration of the SiteManager. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-08-05T20:33:27",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secomea.com/support/cybersecurity-advisory"
        }
      ],
      "source": {
        "defect": [
          "RD-3776"
        ],
        "discovery": "INTERNAL"
      },
      "title": "SiteManager troubleshooter allows access without authentication from local network ",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "VulnerabilityReporting@secomea.com",
          "ID": "CVE-2021-32002",
          "STATE": "PUBLIC",
          "TITLE": "SiteManager troubleshooter allows access without authentication from local network "
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SiteManager",
                      "version": {
                        "version_data": [
                          {
                            "platform": "Hardware",
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "9.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper Access Control vulnerability in web service of Secomea SiteManager allows local attacker without credentials to gather network information and configuration of the SiteManager. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200 Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.secomea.com/support/cybersecurity-advisory",
              "refsource": "MISC",
              "url": "https://www.secomea.com/support/cybersecurity-advisory"
            }
          ]
        },
        "source": {
          "defect": [
            "RD-3776"
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2021-32002",
    "datePublished": "2021-08-05T20:33:27",
    "dateReserved": "2021-05-03T00:00:00",
    "dateUpdated": "2024-08-03T23:17:27.964Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-29020 (GCVE-0-2020-29020)

Vulnerability from cvelistv5 – Published: 2021-03-05 19:12 – Updated: 2024-09-16 18:55
VLAI?
Title
Reject Remote Management via Cellular UPLINK2
Summary
Improper Access Control vulnerability in web service of Secomea SiteManager allows remote attacker to access the web UI from the internet using the configured credentials. This issue affects: Secomea SiteManager All versions prior to 9.4.620527004 on Hardware.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Secomea SiteManager Affected: All , < 9.4.620527004 (custom)
Create a notification for this product.
Credits
TR electronic se
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:48:00.791Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory/#3217"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "Hardware"
          ],
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.4.620527004",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "TR electronic se"
        }
      ],
      "datePublic": "2021-03-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper Access Control vulnerability in web service of Secomea SiteManager allows remote attacker to access the web UI from the internet using the configured credentials. This issue affects: Secomea SiteManager All versions prior to 9.4.620527004 on Hardware."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-03-05T19:12:30",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secomea.com/support/cybersecurity-advisory/#3217"
        }
      ],
      "source": {
        "defect": [
          "RD-3217"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Reject Remote Management via Cellular UPLINK2",
      "workarounds": [
        {
          "lang": "en",
          "value": "Configure Uplink (WAN) to disable management via Uplink"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "VulnerabilityReporting@secomea.com",
          "DATE_PUBLIC": "2021-03-04T22:00:00.000Z",
          "ID": "CVE-2020-29020",
          "STATE": "PUBLIC",
          "TITLE": "Reject Remote Management via Cellular UPLINK2"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SiteManager",
                      "version": {
                        "version_data": [
                          {
                            "platform": "Hardware",
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "9.4.620527004"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "TR electronic se"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper Access Control vulnerability in web service of Secomea SiteManager allows remote attacker to access the web UI from the internet using the configured credentials. This issue affects: Secomea SiteManager All versions prior to 9.4.620527004 on Hardware."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.secomea.com/support/cybersecurity-advisory/#3217",
              "refsource": "MISC",
              "url": "https://www.secomea.com/support/cybersecurity-advisory/#3217"
            }
          ]
        },
        "source": {
          "defect": [
            "RD-3217"
          ],
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Configure Uplink (WAN) to disable management via Uplink"
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2020-29020",
    "datePublished": "2021-03-05T19:12:30.259586Z",
    "dateReserved": "2020-11-24T00:00:00",
    "dateUpdated": "2024-09-16T18:55:36.049Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-29027 (GCVE-0-2020-29027)

Vulnerability from cvelistv5 – Published: 2021-02-16 15:48 – Updated: 2024-09-17 01:05
VLAI?
Title
Reflected Cross Site Scripting
Summary
Cross-site Scripting (XSS) vulnerability in GUI of Secomea SiteManager could allow an attacker to cause an XSS Attack. This issue affects: Secomea SiteManager all versions prior to 9.3.
CWE
  • CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
Vendor Product Version
Secomea SiteManager Affected: all , < 9.3 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:48:00.931Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory/#3042"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.3",
              "status": "affected",
              "version": "all",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2020-12-18T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Cross-site Scripting (XSS) vulnerability in GUI of Secomea SiteManager could allow an attacker to cause an XSS Attack. This issue affects: Secomea SiteManager all versions prior to 9.3."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross-site Scripting (XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-02-16T15:48:58",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secomea.com/support/cybersecurity-advisory/#3042"
        }
      ],
      "source": {
        "defect": [
          "RD-3022"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Reflected Cross Site Scripting",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "VulnerabilityReporting@secomea.com",
          "DATE_PUBLIC": "2020-12-18T00:00:00.000Z",
          "ID": "CVE-2020-29027",
          "STATE": "PUBLIC",
          "TITLE": "Reflected Cross Site Scripting"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SiteManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "all",
                            "version_value": "9.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cross-site Scripting (XSS) vulnerability in GUI of Secomea SiteManager could allow an attacker to cause an XSS Attack. This issue affects: Secomea SiteManager all versions prior to 9.3."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Cross-site Scripting (XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.secomea.com/support/cybersecurity-advisory/#3042",
              "refsource": "MISC",
              "url": "https://www.secomea.com/support/cybersecurity-advisory/#3042"
            }
          ]
        },
        "source": {
          "defect": [
            "RD-3022"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2020-29027",
    "datePublished": "2021-02-16T15:48:58.980830Z",
    "dateReserved": "2020-11-24T00:00:00",
    "dateUpdated": "2024-09-17T01:05:35.165Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-38125 (GCVE-0-2022-38125)

Vulnerability from nvd – Published: 2023-04-19 11:58 – Updated: 2025-02-05 15:00
VLAI?
Title
FTP Agent forwards traffic on inactive ports to LinkManager
Summary
Improper Restriction of Communication Channel to Intended Endpoints vulnerability in Secomea SiteManager (FTP Agent modules) allows Exploiting Trust in Client.
CWE
  • CWE-923 - Improper Restriction of Communication Channel to Intended Endpoints
Assigner
Impacted products
Vendor Product Version
Secomea SiteManager Affected: 5.0 , ≤ 10.0 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:45:52.834Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-38125",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-05T14:59:41.569876Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-923",
                "description": "CWE-923 Improper Restriction of Communication Channel to Intended Endpoints",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T15:00:42.143Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "FTP Agent"
          ],
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThanOrEqual": "10.0",
              "status": "affected",
              "version": "5.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2023-04-19T11:58:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Restriction of Communication Channel to Intended Endpoints vulnerability in Secomea SiteManager (FTP Agent modules) allows Exploiting Trust in Client."
            }
          ],
          "value": "Improper Restriction of Communication Channel to Intended Endpoints vulnerability in Secomea SiteManager (FTP Agent modules) allows Exploiting Trust in Client."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-22",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-22 Exploiting Trust in Client"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 2.9,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:C/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-923",
              "description": "CWE-923 Improper Restriction of Communication Channel to Intended Endpoints",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-19T11:58:14.508Z",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "url": "https://www.secomea.com/support/cybersecurity-advisory/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "FTP Agent forwards traffic on inactive ports to LinkManager",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2022-38125",
    "datePublished": "2023-04-19T11:58:14.508Z",
    "dateReserved": "2022-08-10T09:46:05.634Z",
    "dateUpdated": "2025-02-05T15:00:42.143Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-38124 (GCVE-0-2022-38124)

Vulnerability from nvd – Published: 2022-12-13 13:06 – Updated: 2025-04-18 15:28
VLAI?
Title
Unwanted debug tool
Summary
Debug tool in Secomea SiteManager allows logged-in administrator to modify system state in an unintended manner.
CWE
  • CWE-267 - Privilege Defined With Unsafe Actions
Assigner
Impacted products
Vendor Product Version
Secomea SiteManager Affected: 0 , ≤ 10.0.622425017 ("custom")
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:45:52.627Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-38124",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:28:06.181233Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-18T15:28:20.215Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThanOrEqual": "10.0.622425017",
              "status": "affected",
              "version": "0",
              "versionType": "\"custom\""
            }
          ]
        }
      ],
      "datePublic": "2022-12-12T23:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Debug tool in Secomea SiteManager allows logged-in administrator to modify system state in an unintended manner."
            }
          ],
          "value": "Debug tool in Secomea SiteManager allows logged-in administrator to modify system state in an unintended manner."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-121",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-121 Exploit Test APIs"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-267",
              "description": "CWE-267 Privilege Defined With Unsafe Actions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-13T13:06:17.021Z",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "url": "https://www.secomea.com/support/cybersecurity-advisory/"
        }
      ],
      "source": {
        "defect": [
          "RD-6294"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Unwanted debug tool",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2022-38124",
    "datePublished": "2022-12-13T13:06:17.021Z",
    "dateReserved": "2022-08-10T09:46:05.634Z",
    "dateUpdated": "2025-04-18T15:28:20.215Z",
    "requesterUserId": "44bd1e71-3702-434c-b36b-c1ac3bb0bab6",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25785 (GCVE-0-2022-25785)

Vulnerability from nvd – Published: 2022-05-04 13:57 – Updated: 2024-08-03 04:49
VLAI?
Title
Buffer overrun
Summary
Stack-based Buffer Overflow vulnerability in SiteManager allows logged-in or local user to cause arbitrary code execution. This issue affects: Secomea SiteManager all versions prior to 9.7.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Secomea SiteManager Affected: all , < 9.7 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:49:43.219Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.7",
              "status": "affected",
              "version": "all",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based Buffer Overflow vulnerability in SiteManager allows logged-in or local user to cause arbitrary code execution. This issue affects: Secomea SiteManager all versions prior to 9.7."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-04T13:57:06",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secomea.com/support/cybersecurity-advisory/"
        }
      ],
      "source": {
        "defect": [
          "RD-5455"
        ],
        "discovery": "INTERNAL"
      },
      "title": "Buffer overrun",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "VulnerabilityReporting@secomea.com",
          "ID": "CVE-2022-25785",
          "STATE": "PUBLIC",
          "TITLE": "Buffer overrun"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SiteManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "all",
                            "version_value": "9.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Stack-based Buffer Overflow vulnerability in SiteManager allows logged-in or local user to cause arbitrary code execution. This issue affects: Secomea SiteManager all versions prior to 9.7."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121 Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.secomea.com/support/cybersecurity-advisory/",
              "refsource": "MISC",
              "url": "https://www.secomea.com/support/cybersecurity-advisory/"
            }
          ]
        },
        "source": {
          "defect": [
            "RD-5455"
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2022-25785",
    "datePublished": "2022-05-04T13:57:06",
    "dateReserved": "2022-02-22T00:00:00",
    "dateUpdated": "2024-08-03T04:49:43.219Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25784 (GCVE-0-2022-25784)

Vulnerability from nvd – Published: 2022-05-04 13:56 – Updated: 2024-08-03 04:49
VLAI?
Title
User controllable HTML element attribute (potential XSS)
Summary
Cross-site Scripting (XSS) vulnerability in Web GUI of SiteManager allows logged-in user to inject scripting. This issue affects: Secomea SiteManager all versions prior to 9.7.
CWE
  • CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
Vendor Product Version
Secomea SiteManager Affected: all , < 9.7 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:49:43.564Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.7",
              "status": "affected",
              "version": "all",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Cross-site Scripting (XSS) vulnerability in Web GUI of SiteManager allows logged-in user to inject scripting. This issue affects: Secomea SiteManager all versions prior to 9.7."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross-site Scripting (XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-04T13:56:20",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secomea.com/support/cybersecurity-advisory/"
        }
      ],
      "source": {
        "defect": [
          "RD-5371"
        ],
        "discovery": "INTERNAL"
      },
      "title": "User controllable HTML element attribute (potential XSS)",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "VulnerabilityReporting@secomea.com",
          "ID": "CVE-2022-25784",
          "STATE": "PUBLIC",
          "TITLE": "User controllable HTML element attribute (potential XSS)"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SiteManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "all",
                            "version_value": "9.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cross-site Scripting (XSS) vulnerability in Web GUI of SiteManager allows logged-in user to inject scripting. This issue affects: Secomea SiteManager all versions prior to 9.7."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Cross-site Scripting (XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.secomea.com/support/cybersecurity-advisory/",
              "refsource": "MISC",
              "url": "https://www.secomea.com/support/cybersecurity-advisory/"
            }
          ]
        },
        "source": {
          "defect": [
            "RD-5371"
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2022-25784",
    "datePublished": "2022-05-04T13:56:20",
    "dateReserved": "2022-02-22T00:00:00",
    "dateUpdated": "2024-08-03T04:49:43.564Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-32010 (GCVE-0-2021-32010)

Vulnerability from nvd – Published: 2022-05-04 13:45 – Updated: 2024-08-03 23:17
VLAI?
Title
Clients may connect to a GateManager with TLS 1.0
Summary
Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7.
CWE
  • CWE-326 - Inadequate Encryption Strength
Assigner
References
Impacted products
Vendor Product Version
Secomea SiteManager Affected: All , < 9.7 (custom)
Create a notification for this product.
    Secomea LinkManager Affected: unspecified , < 9.7 (custom)
Create a notification for this product.
    Secomea GateManager Affected: unspecified , < 9.7 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:17:28.463Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.7",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "LinkManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.7",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "GateManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.7",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-326",
              "description": "CWE-326 Inadequate Encryption Strength",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-04T13:45:03",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secomea.com/support/cybersecurity-advisory/"
        }
      ],
      "source": {
        "defect": [
          "RD-5699"
        ],
        "discovery": "INTERNAL"
      },
      "title": "Clients may connect to a GateManager with TLS 1.0",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "VulnerabilityReporting@secomea.com",
          "ID": "CVE-2021-32010",
          "STATE": "PUBLIC",
          "TITLE": "Clients may connect to a GateManager with TLS 1.0"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SiteManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "9.7"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "LinkManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "9.7"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GateManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "9.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-326 Inadequate Encryption Strength"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.secomea.com/support/cybersecurity-advisory/",
              "refsource": "MISC",
              "url": "https://www.secomea.com/support/cybersecurity-advisory/"
            }
          ]
        },
        "source": {
          "defect": [
            "RD-5699"
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2021-32010",
    "datePublished": "2022-05-04T13:45:03",
    "dateReserved": "2021-05-03T00:00:00",
    "dateUpdated": "2024-08-03T23:17:28.463Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-32005 (GCVE-0-2021-32005)

Vulnerability from nvd – Published: 2022-03-07 15:21 – Updated: 2024-08-03 23:17
VLAI?
Title
SiteManager Log View XSS Issue
Summary
Cross-site Scripting (XSS) vulnerability in log view of Secomea SiteManager allows a logged in user to store javascript for later execution. This issue affects: Secomea SiteManager Version 9.6.621421014 and all prior versions.
CWE
  • CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
Vendor Product Version
Secomea SiteManager Affected: All , ≤ 9.6.621421014 (custom)
Create a notification for this product.
Credits
Schlumberger
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:17:27.941Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory/#5017"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThanOrEqual": "9.6.621421014",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Schlumberger"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Cross-site Scripting (XSS) vulnerability in log view of Secomea SiteManager allows a logged in user to store javascript for later execution. This issue affects: Secomea SiteManager Version 9.6.621421014 and all prior versions."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross-site Scripting (XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-07T15:21:27",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secomea.com/support/cybersecurity-advisory/#5017"
        }
      ],
      "source": {
        "defect": [
          "RD-5017"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "SiteManager Log View XSS Issue",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "VulnerabilityReporting@secomea.com",
          "ID": "CVE-2021-32005",
          "STATE": "PUBLIC",
          "TITLE": "SiteManager Log View XSS Issue"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SiteManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "9.6.621421014"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Schlumberger"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cross-site Scripting (XSS) vulnerability in log view of Secomea SiteManager allows a logged in user to store javascript for later execution. This issue affects: Secomea SiteManager Version 9.6.621421014 and all prior versions."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Cross-site Scripting (XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.secomea.com/support/cybersecurity-advisory/#5017",
              "refsource": "MISC",
              "url": "https://www.secomea.com/support/cybersecurity-advisory/#5017"
            }
          ]
        },
        "source": {
          "defect": [
            "RD-5017"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2021-32005",
    "datePublished": "2022-03-07T15:21:27",
    "dateReserved": "2021-05-03T00:00:00",
    "dateUpdated": "2024-08-03T23:17:27.941Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-32003 (GCVE-0-2021-32003)

Vulnerability from nvd – Published: 2021-08-05 20:33 – Updated: 2024-08-03 23:17
VLAI?
Title
Configuration service port remains open 10 minutes after reboot even when already provisioned
Summary
Unprotected Transport of Credentials vulnerability in SiteManager provisioning service allows local attacker to capture credentials if the service is used after provisioning. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware.
CWE
  • CWE-523 - Unprotected Transport of Credentials
Assigner
References
Impacted products
Vendor Product Version
Secomea SiteManager Affected: All , < 9.5 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:17:27.897Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "Hardware"
          ],
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.5",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Unprotected Transport of Credentials vulnerability in SiteManager provisioning service allows local attacker to capture credentials if the service is used after provisioning. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-523",
              "description": "CWE-523 Unprotected Transport of Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-08-05T20:33:30",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secomea.com/support/cybersecurity-advisory"
        }
      ],
      "source": {
        "defect": [
          "RD-3777"
        ],
        "discovery": "INTERNAL"
      },
      "title": "Configuration service port remains open 10 minutes after reboot even when already provisioned",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "VulnerabilityReporting@secomea.com",
          "ID": "CVE-2021-32003",
          "STATE": "PUBLIC",
          "TITLE": "Configuration service port remains open 10 minutes after reboot even when already provisioned"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SiteManager",
                      "version": {
                        "version_data": [
                          {
                            "platform": "Hardware",
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "9.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Unprotected Transport of Credentials vulnerability in SiteManager provisioning service allows local attacker to capture credentials if the service is used after provisioning. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-523 Unprotected Transport of Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.secomea.com/support/cybersecurity-advisory",
              "refsource": "MISC",
              "url": "https://www.secomea.com/support/cybersecurity-advisory"
            }
          ]
        },
        "source": {
          "defect": [
            "RD-3777"
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2021-32003",
    "datePublished": "2021-08-05T20:33:30",
    "dateReserved": "2021-05-03T00:00:00",
    "dateUpdated": "2024-08-03T23:17:27.897Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-32002 (GCVE-0-2021-32002)

Vulnerability from nvd – Published: 2021-08-05 20:33 – Updated: 2024-08-03 23:17
VLAI?
Title
SiteManager troubleshooter allows access without authentication from local network
Summary
Improper Access Control vulnerability in web service of Secomea SiteManager allows local attacker without credentials to gather network information and configuration of the SiteManager. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware.
CWE
Assigner
References
Impacted products
Vendor Product Version
Secomea SiteManager Affected: All , < 9.5 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:17:27.964Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "Hardware"
          ],
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.5",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper Access Control vulnerability in web service of Secomea SiteManager allows local attacker without credentials to gather network information and configuration of the SiteManager. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-08-05T20:33:27",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secomea.com/support/cybersecurity-advisory"
        }
      ],
      "source": {
        "defect": [
          "RD-3776"
        ],
        "discovery": "INTERNAL"
      },
      "title": "SiteManager troubleshooter allows access without authentication from local network ",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "VulnerabilityReporting@secomea.com",
          "ID": "CVE-2021-32002",
          "STATE": "PUBLIC",
          "TITLE": "SiteManager troubleshooter allows access without authentication from local network "
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SiteManager",
                      "version": {
                        "version_data": [
                          {
                            "platform": "Hardware",
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "9.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper Access Control vulnerability in web service of Secomea SiteManager allows local attacker without credentials to gather network information and configuration of the SiteManager. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200 Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.secomea.com/support/cybersecurity-advisory",
              "refsource": "MISC",
              "url": "https://www.secomea.com/support/cybersecurity-advisory"
            }
          ]
        },
        "source": {
          "defect": [
            "RD-3776"
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2021-32002",
    "datePublished": "2021-08-05T20:33:27",
    "dateReserved": "2021-05-03T00:00:00",
    "dateUpdated": "2024-08-03T23:17:27.964Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-29020 (GCVE-0-2020-29020)

Vulnerability from nvd – Published: 2021-03-05 19:12 – Updated: 2024-09-16 18:55
VLAI?
Title
Reject Remote Management via Cellular UPLINK2
Summary
Improper Access Control vulnerability in web service of Secomea SiteManager allows remote attacker to access the web UI from the internet using the configured credentials. This issue affects: Secomea SiteManager All versions prior to 9.4.620527004 on Hardware.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Secomea SiteManager Affected: All , < 9.4.620527004 (custom)
Create a notification for this product.
Credits
TR electronic se
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:48:00.791Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory/#3217"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "Hardware"
          ],
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.4.620527004",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "TR electronic se"
        }
      ],
      "datePublic": "2021-03-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper Access Control vulnerability in web service of Secomea SiteManager allows remote attacker to access the web UI from the internet using the configured credentials. This issue affects: Secomea SiteManager All versions prior to 9.4.620527004 on Hardware."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-03-05T19:12:30",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secomea.com/support/cybersecurity-advisory/#3217"
        }
      ],
      "source": {
        "defect": [
          "RD-3217"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Reject Remote Management via Cellular UPLINK2",
      "workarounds": [
        {
          "lang": "en",
          "value": "Configure Uplink (WAN) to disable management via Uplink"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "VulnerabilityReporting@secomea.com",
          "DATE_PUBLIC": "2021-03-04T22:00:00.000Z",
          "ID": "CVE-2020-29020",
          "STATE": "PUBLIC",
          "TITLE": "Reject Remote Management via Cellular UPLINK2"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SiteManager",
                      "version": {
                        "version_data": [
                          {
                            "platform": "Hardware",
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "9.4.620527004"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "TR electronic se"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper Access Control vulnerability in web service of Secomea SiteManager allows remote attacker to access the web UI from the internet using the configured credentials. This issue affects: Secomea SiteManager All versions prior to 9.4.620527004 on Hardware."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.secomea.com/support/cybersecurity-advisory/#3217",
              "refsource": "MISC",
              "url": "https://www.secomea.com/support/cybersecurity-advisory/#3217"
            }
          ]
        },
        "source": {
          "defect": [
            "RD-3217"
          ],
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Configure Uplink (WAN) to disable management via Uplink"
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2020-29020",
    "datePublished": "2021-03-05T19:12:30.259586Z",
    "dateReserved": "2020-11-24T00:00:00",
    "dateUpdated": "2024-09-16T18:55:36.049Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-29027 (GCVE-0-2020-29027)

Vulnerability from nvd – Published: 2021-02-16 15:48 – Updated: 2024-09-17 01:05
VLAI?
Title
Reflected Cross Site Scripting
Summary
Cross-site Scripting (XSS) vulnerability in GUI of Secomea SiteManager could allow an attacker to cause an XSS Attack. This issue affects: Secomea SiteManager all versions prior to 9.3.
CWE
  • CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
Vendor Product Version
Secomea SiteManager Affected: all , < 9.3 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:48:00.931Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory/#3042"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.3",
              "status": "affected",
              "version": "all",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2020-12-18T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Cross-site Scripting (XSS) vulnerability in GUI of Secomea SiteManager could allow an attacker to cause an XSS Attack. This issue affects: Secomea SiteManager all versions prior to 9.3."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross-site Scripting (XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-02-16T15:48:58",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secomea.com/support/cybersecurity-advisory/#3042"
        }
      ],
      "source": {
        "defect": [
          "RD-3022"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Reflected Cross Site Scripting",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "VulnerabilityReporting@secomea.com",
          "DATE_PUBLIC": "2020-12-18T00:00:00.000Z",
          "ID": "CVE-2020-29027",
          "STATE": "PUBLIC",
          "TITLE": "Reflected Cross Site Scripting"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SiteManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "all",
                            "version_value": "9.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cross-site Scripting (XSS) vulnerability in GUI of Secomea SiteManager could allow an attacker to cause an XSS Attack. This issue affects: Secomea SiteManager all versions prior to 9.3."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Cross-site Scripting (XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.secomea.com/support/cybersecurity-advisory/#3042",
              "refsource": "MISC",
              "url": "https://www.secomea.com/support/cybersecurity-advisory/#3042"
            }
          ]
        },
        "source": {
          "defect": [
            "RD-3022"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2020-29027",
    "datePublished": "2021-02-16T15:48:58.980830Z",
    "dateReserved": "2020-11-24T00:00:00",
    "dateUpdated": "2024-09-17T01:05:35.165Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

VAR-202108-1748

Vulnerability from variot - Updated: 2021-12-18 08:37

Improper Access Control vulnerability in web service of Secomea SiteManager allows local attacker without credentials to gather network information and configuration of the SiteManager. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202108-1748",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "sitemanager",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "secomea",
        "version": "9.5.621256022"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-32002"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:secomea:sitemanager_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "9.5.621256022",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:secomea:sitemanager:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:secomea:sitemanager_firmware:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "9.5.621256022",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:secomea:sitemanager:-:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": false
              }
            ],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-32002"
      }
    ]
  },
  "cve": "CVE-2021-32002",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 2.1,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "CVE-2021-32002",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "LOW",
            "trust": 1.1,
            "userInteractionRequired": false,
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 1.8,
            "id": "CVE-2021-32002",
            "impactScore": 1.4,
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2021-32002",
            "trust": 1.0,
            "value": "LOW"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202108-524",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-32002",
            "trust": 0.1,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-32002"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-524"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-32002"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Improper Access Control vulnerability in web service of Secomea SiteManager allows local attacker without credentials to gather network information and configuration of the SiteManager. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-32002"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-32002"
      }
    ],
    "trust": 0.99
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-32002",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-524",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-32002",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-32002"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-524"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-32002"
      }
    ]
  },
  "id": "VAR-202108-1748",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.5
  },
  "last_update_date": "2021-12-18T08:37:55.140000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-863",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-32002"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://www.secomea.com/support/cybersecurity-advisory"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-32002"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/863.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-32002"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-524"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-32002"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-32002"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-524"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-32002"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-08-05T21:15:00",
        "db": "NVD",
        "id": "CVE-2021-32002"
      },
      {
        "date": "2021-08-05T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202108-524"
      },
      {
        "date": "2021-08-05T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-32002"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-08-13T19:10:00",
        "db": "NVD",
        "id": "CVE-2021-32002"
      },
      {
        "date": "2021-08-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202108-524"
      },
      {
        "date": "2021-08-13T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-32002"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-524"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Secomea SiteManager Security hole",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-524"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-524"
      }
    ],
    "trust": 0.6
  }
}

VAR-202108-1749

Vulnerability from variot - Updated: 2021-12-18 08:25

Unprotected Transport of Credentials vulnerability in SiteManager provisioning service allows local attacker to capture credentials if the service is used after provisioning. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202108-1749",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "sitemanager",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "secomea",
        "version": "9.5.621256022"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-32003"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:secomea:sitemanager_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "9.5.621256022",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:secomea:sitemanager:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:secomea:sitemanager_firmware:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "9.5.621256022",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:secomea:sitemanager:-:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": false
              }
            ],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-32003"
      }
    ]
  },
  "cve": "CVE-2021-32003",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 2.1,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "CVE-2021-32003",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "LOW",
            "trust": 1.1,
            "userInteractionRequired": false,
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2021-32003",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2021-32003",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202108-525",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-32003",
            "trust": 0.1,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-32003"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-525"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-32003"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Unprotected Transport of Credentials vulnerability in SiteManager provisioning service allows local attacker to capture credentials if the service is used after provisioning. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-32003"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-32003"
      }
    ],
    "trust": 0.99
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-32003",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-525",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-32003",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-32003"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-525"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-32003"
      }
    ]
  },
  "id": "VAR-202108-1749",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.5
  },
  "last_update_date": "2021-12-18T08:25:41.629000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-522",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-32003"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://www.secomea.com/support/cybersecurity-advisory"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-32003"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/522.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-32003"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-525"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-32003"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-32003"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-525"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-32003"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-08-05T21:15:00",
        "db": "NVD",
        "id": "CVE-2021-32003"
      },
      {
        "date": "2021-08-05T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202108-525"
      },
      {
        "date": "2021-08-05T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-32003"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-08-13T19:16:00",
        "db": "NVD",
        "id": "CVE-2021-32003"
      },
      {
        "date": "2021-08-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202108-525"
      },
      {
        "date": "2021-08-13T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-32003"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-525"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Secomea SiteManager Security hole",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-525"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-525"
      }
    ],
    "trust": 0.6
  }
}

VAR-202103-0241

Vulnerability from variot - Updated: 2021-12-17 06:53

Improper Access Control vulnerability in web service of Secomea SiteManager allows remote attacker to access the web UI from the internet using the configured credentials. This issue affects: Secomea SiteManager All versions prior to 9.4.620527004 on Hardware. Secomea SiteManager Contains an improper authentication vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202103-0241",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "sitemanager",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "secomea",
        "version": "9.4.620527004"
      },
      {
        "model": "sitemanager",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "secomea",
        "version": null
      },
      {
        "model": "sitemanager",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "secomea",
        "version": "sitemanager  firmware  9.4.620527004"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-29020"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-016355"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:secomea:sitemanager_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "9.4.620527004",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:secomea:sitemanager:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:secomea:sitemanager_firmware:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "9.4.620527004",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:secomea:sitemanager:-:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": false
              }
            ],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-29020"
      }
    ]
  },
  "cve": "CVE-2020-29020",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CVE-2020-29020",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.8,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.2,
            "id": "CVE-2020-29020",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.2,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2020-29020",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "High",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2020-29020",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202103-531",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-29020"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202103-531"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-016355"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Improper Access Control vulnerability in web service of Secomea SiteManager allows remote attacker to access the web UI from the internet using the configured credentials. This issue affects: Secomea SiteManager All versions prior to 9.4.620527004 on Hardware. Secomea SiteManager Contains an improper authentication vulnerability.Information is obtained, information is tampered with, and service is disrupted  (DoS) It may be put into a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-29020"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-016355"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-29020",
        "trust": 2.4
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-016355",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202103-531",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-29020"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202103-531"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-016355"
      }
    ]
  },
  "id": "VAR-202103-0241",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.5
  },
  "last_update_date": "2021-12-17T06:53:48.780000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "CYBERSECURITY\u00a0ADVISORY",
        "trust": 0.8,
        "url": "https://www.secomea.com/support/cybersecurity-advisory/#3217"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-016355"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-863",
        "trust": 1.0
      },
      {
        "problemtype": "Bad authentication (CWE-863) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-29020"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-016355"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://www.secomea.com/support/cybersecurity-advisory/#3217"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-29020"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-29020"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202103-531"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-016355"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-29020"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202103-531"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-016355"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-03-05T21:15:00",
        "db": "NVD",
        "id": "CVE-2020-29020"
      },
      {
        "date": "2021-03-05T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202103-531"
      },
      {
        "date": "2021-11-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-016355"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-03-12T15:22:00",
        "db": "NVD",
        "id": "CVE-2020-29020"
      },
      {
        "date": "2021-03-19T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202103-531"
      },
      {
        "date": "2021-11-25T07:08:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-016355"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202103-531"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Secomea\u00a0SiteManager\u00a0 Authentication Vulnerability in Microsoft",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-016355"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "access control error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202103-531"
      }
    ],
    "trust": 0.6
  }
}