CVE-2020-29020 (GCVE-0-2020-29020)
Vulnerability from cvelistv5 – Published: 2021-03-05 19:12 – Updated: 2024-09-16 18:55
VLAI?
Summary
Improper Access Control vulnerability in web service of Secomea SiteManager allows remote attacker to access the web UI from the internet using the configured credentials. This issue affects: Secomea SiteManager All versions prior to 9.4.620527004 on Hardware.
Severity ?
9.1 (Critical)
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | SiteManager |
Affected:
All , < 9.4.620527004
(custom)
|
Credits
TR electronic se
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:00.791Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#3217"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"platforms": [
"Hardware"
],
"product": "SiteManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.4.620527004",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "TR electronic se"
}
],
"datePublic": "2021-03-04T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Improper Access Control vulnerability in web service of Secomea SiteManager allows remote attacker to access the web UI from the internet using the configured credentials. This issue affects: Secomea SiteManager All versions prior to 9.4.620527004 on Hardware."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-05T19:12:30",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#3217"
}
],
"source": {
"defect": [
"RD-3217"
],
"discovery": "EXTERNAL"
},
"title": "Reject Remote Management via Cellular UPLINK2",
"workarounds": [
{
"lang": "en",
"value": "Configure Uplink (WAN) to disable management via Uplink"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"DATE_PUBLIC": "2021-03-04T22:00:00.000Z",
"ID": "CVE-2020-29020",
"STATE": "PUBLIC",
"TITLE": "Reject Remote Management via Cellular UPLINK2"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SiteManager",
"version": {
"version_data": [
{
"platform": "Hardware",
"version_affected": "\u003c",
"version_name": "All",
"version_value": "9.4.620527004"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "TR electronic se"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Access Control vulnerability in web service of Secomea SiteManager allows remote attacker to access the web UI from the internet using the configured credentials. This issue affects: Secomea SiteManager All versions prior to 9.4.620527004 on Hardware."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284 Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/#3217",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/#3217"
}
]
},
"source": {
"defect": [
"RD-3217"
],
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Configure Uplink (WAN) to disable management via Uplink"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2020-29020",
"datePublished": "2021-03-05T19:12:30.259586Z",
"dateReserved": "2020-11-24T00:00:00",
"dateUpdated": "2024-09-16T18:55:36.049Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:secomea:sitemanager_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"9.4.620527004\", \"matchCriteriaId\": \"EEE45259-4860-4F8C-BC4B-AA5B45FE8CD9\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:secomea:sitemanager:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5DEE66B6-F0A6-4172-8795-48A6DF6A61E9\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Improper Access Control vulnerability in web service of Secomea SiteManager allows remote attacker to access the web UI from the internet using the configured credentials. This issue affects: Secomea SiteManager All versions prior to 9.4.620527004 on Hardware.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad de Control de Acceso Inapropiado en el servicio web de Secomea SiteManager, permite a un atacante remoto acceder a la interfaz de usuario web desde Internet usando las credenciales configuradas.\u0026#xa0;Este problema afecta a: Secomea SiteManager Todas las versiones anteriores a 9.4.620527004 en hardware\"}]",
"id": "CVE-2020-29020",
"lastModified": "2024-11-21T05:23:31.227",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"VulnerabilityReporting@secomea.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\", \"baseScore\": 9.1, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.3, \"impactScore\": 6.0}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.2, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.2, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:P/A:P\", \"baseScore\": 6.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.0, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2021-03-05T21:15:12.420",
"references": "[{\"url\": \"https://www.secomea.com/support/cybersecurity-advisory/#3217\", \"source\": \"VulnerabilityReporting@secomea.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.secomea.com/support/cybersecurity-advisory/#3217\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "VulnerabilityReporting@secomea.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"VulnerabilityReporting@secomea.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-284\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-863\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-29020\",\"sourceIdentifier\":\"VulnerabilityReporting@secomea.com\",\"published\":\"2021-03-05T21:15:12.420\",\"lastModified\":\"2024-11-21T05:23:31.227\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper Access Control vulnerability in web service of Secomea SiteManager allows remote attacker to access the web UI from the internet using the configured credentials. This issue affects: Secomea SiteManager All versions prior to 9.4.620527004 on Hardware.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de Control de Acceso Inapropiado en el servicio web de Secomea SiteManager, permite a un atacante remoto acceder a la interfaz de usuario web desde Internet usando las credenciales configuradas.\u0026#xa0;Este problema afecta a: Secomea SiteManager Todas las versiones anteriores a 9.4.620527004 en hardware\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"VulnerabilityReporting@secomea.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.3,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"VulnerabilityReporting@secomea.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-863\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:secomea:sitemanager_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.4.620527004\",\"matchCriteriaId\":\"EEE45259-4860-4F8C-BC4B-AA5B45FE8CD9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:secomea:sitemanager:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5DEE66B6-F0A6-4172-8795-48A6DF6A61E9\"}]}]}],\"references\":[{\"url\":\"https://www.secomea.com/support/cybersecurity-advisory/#3217\",\"source\":\"VulnerabilityReporting@secomea.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.secomea.com/support/cybersecurity-advisory/#3217\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…