Vulnerabilites related to siemens - solid_edge_se2023
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:48
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C", "versionEndExcluding": "2210.0002.004", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "id": "CVE-2023-24557", "lastModified": "2024-11-21T07:48:07.300", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:15.563", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:48
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to heap-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C", "versionEndExcluding": "2210.0002.004", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application is vulnerable to heap-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "id": "CVE-2023-24550", "lastModified": "2024-11-21T07:48:06.437", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:14.967", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-122" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-01-09 10:15
Modified
2024-11-21 08:32
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "6708C521-2523-4FFE-8D66-01386DF0FAAF", "versionEndExcluding": "223.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:-:*:*:*:*:*:*", "matchCriteriaId": "E0ADA2C0-4AA2-4FDB-AB71-2C905106A68F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0001:*:*:*:*:*:*", "matchCriteriaId": "619B13A0-ADF3-4CC9-A5BD-6C99AE369D43", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0002:*:*:*:*:*:*", "matchCriteriaId": "E4C4B3EA-853A-4C75-AA5F-319E2802A722", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0003:*:*:*:*:*:*", "matchCriteriaId": "28C04B66-7E6F-49E6-B7A9-E7357ADE5936", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0004:*:*:*:*:*:*", "matchCriteriaId": "99A72C67-00A3-499A-9DDC-73AD29672A08", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0005:*:*:*:*:*:*", "matchCriteriaId": "9C7B34D6-925F-4DB9-8418-962F35FE11C6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0006:*:*:*:*:*:*", "matchCriteriaId": "211C7830-D4B9-4315-BDE8-F108FF6A609C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0007:*:*:*:*:*:*", "matchCriteriaId": "52647713-2F45-4D35-B31A-5BB2E15175EF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0008:*:*:*:*:*:*", "matchCriteriaId": "4378378B-BAEA-4200-9336-936835322DF6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0009:*:*:*:*:*:*", "matchCriteriaId": "57968030-2B5F-41C1-B8B4-2405C84E3A06", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Solid Edge SE2023 (todas las versiones " } ], "id": "CVE-2023-49131", "lastModified": "2024-11-21T08:32:53.917", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-01-09T10:15:19.310", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-824" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:48
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2022 | - | |
siemens | solid_edge_se2022 | maintenance_pack_1 | |
siemens | solid_edge_se2022 | maintenance_pack_2 | |
siemens | solid_edge_se2022 | maintenance_pack_3 | |
siemens | solid_edge_se2022 | maintenance_pack_4 | |
siemens | solid_edge_se2022 | maintenance_pack_5 | |
siemens | solid_edge_se2022 | maintenance_pack_7 | |
siemens | solid_edge_se2022 | maintenance_pack_8 | |
siemens | solid_edge_se2022 | maintenance_pack_9 | |
siemens | solid_edge_se2022 | maintenance_pack_10 | |
siemens | solid_edge_se2022 | maintenance_pack_11 | |
siemens | solid_edge_se2023 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "22C0D3BE-0640-49C8-86F1-52966CABA2E2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_1:*:*:*:*:*:*:*", "matchCriteriaId": "DE12CBDF-222E-4DE9-927A-3BDDBFFF1E1A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_2:*:*:*:*:*:*:*", "matchCriteriaId": "EEFAAAE5-52B1-48EA-98E1-98A854CBE65A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_3:*:*:*:*:*:*:*", "matchCriteriaId": "D5AFCFBB-ED56-4DDB-89D8-B47A20821AB8", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_4:*:*:*:*:*:*:*", "matchCriteriaId": "087A9E78-9E5C-4D94-A251-02F9AB160F54", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_5:*:*:*:*:*:*:*", "matchCriteriaId": "68EE0588-FE7F-4581-9484-52404DB5B99A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_7:*:*:*:*:*:*:*", "matchCriteriaId": "9F72318F-0E9C-4AB1-9CA2-6527513AE0F6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_8:*:*:*:*:*:*:*", "matchCriteriaId": "63C93992-17F7-4499-BC57-BD67E8A6C508", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_9:*:*:*:*:*:*:*", "matchCriteriaId": "7180CEA7-150A-4B1D-BDFD-61C320A33148", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_10:*:*:*:*:*:*:*", "matchCriteriaId": "B0244EE5-BF22-491A-A7DE-48F44E2A17FC", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_11:*:*:*:*:*:*:*", "matchCriteriaId": "3A583AAD-5B13-4822-AA24-AA7D16305FE2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C", "versionEndExcluding": "2210.0002.004", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process." } ], "id": "CVE-2023-24552", "lastModified": "2024-11-21T07:48:06.677", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:15.137", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-12-13 16:15
Modified
2024-11-21 07:30
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19071)
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | parasolid | * | |
siemens | parasolid | * | |
siemens | parasolid | * | |
siemens | parasolid | * | |
siemens | solid_edge_se2022 | * | |
siemens | solid_edge_se2023 | - | |
siemens | solid_edge_se2023 | 223.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "matchCriteriaId": "F1405366-A402-4908-858D-E844853BE1DA", "versionEndExcluding": "33.1.264", "versionStartIncluding": "33.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "matchCriteriaId": "F0D9079D-6138-4602-A982-9BC4ECBC35E7", "versionEndExcluding": "34.0.252", "versionStartIncluding": "34.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C486991-A1C0-4815-AAD6-163464D711AA", "versionEndExcluding": "34.1.242", "versionStartIncluding": "34.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA2114FD-BB07-4C24-98B1-928A510565BB", "versionEndExcluding": "35.0.170", "versionStartIncluding": "35.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FF17E24-2697-4110-8A0F-BC76BA617C76", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:-:*:*:*:*:*:*:*", "matchCriteriaId": "60B92DC2-5A0D-4F6E-81FD-3A0CA25B0D32", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:-:*:*:*:*:*:*", "matchCriteriaId": "E0ADA2C0-4AA2-4FDB-AB71-2C905106A68F", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19071)" }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en:\nParasolid V33.1 (Todas las versiones \u0026lt; V33.1.264), \nParasolid V34.0 (Todas las versiones \u0026lt; V34.0.252), \nParasolid V34.1 (Todas las versiones \u0026lt; V34.1.242), \nParasolid V35 .0 (Todas las versiones \u0026lt; V35.0.170), \nSolid Edge SE2022 (Todas las versiones \u0026lt; V222.0MP12), \nSolid Edge SE2022 (Todas las versiones), \nSolid Edge SE2023 (Todas las versiones \u0026lt; V223.0Update2). \nLas aplicaciones afectadas contienen una escritura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada mientras analizan archivos X_B especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-19071)" } ], "id": "CVE-2022-46346", "lastModified": "2024-11-21T07:30:25.910", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2022-12-13T16:15:25.393", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-01-09 10:15
Modified
2024-11-21 08:32
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "6708C521-2523-4FFE-8D66-01386DF0FAAF", "versionEndExcluding": "223.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:-:*:*:*:*:*:*", "matchCriteriaId": "E0ADA2C0-4AA2-4FDB-AB71-2C905106A68F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0001:*:*:*:*:*:*", "matchCriteriaId": "619B13A0-ADF3-4CC9-A5BD-6C99AE369D43", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0002:*:*:*:*:*:*", "matchCriteriaId": "E4C4B3EA-853A-4C75-AA5F-319E2802A722", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0003:*:*:*:*:*:*", "matchCriteriaId": "28C04B66-7E6F-49E6-B7A9-E7357ADE5936", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0004:*:*:*:*:*:*", "matchCriteriaId": "99A72C67-00A3-499A-9DDC-73AD29672A08", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0005:*:*:*:*:*:*", "matchCriteriaId": "9C7B34D6-925F-4DB9-8418-962F35FE11C6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0006:*:*:*:*:*:*", "matchCriteriaId": "211C7830-D4B9-4315-BDE8-F108FF6A609C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0007:*:*:*:*:*:*", "matchCriteriaId": "52647713-2F45-4D35-B31A-5BB2E15175EF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0008:*:*:*:*:*:*", "matchCriteriaId": "4378378B-BAEA-4200-9336-936835322DF6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0009:*:*:*:*:*:*", "matchCriteriaId": "57968030-2B5F-41C1-B8B4-2405C84E3A06", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Solid Edge SE2023 (todas las versiones " } ], "id": "CVE-2023-49123", "lastModified": "2024-11-21T08:32:52.790", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-01-09T10:15:17.457", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-122" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-01-09 10:15
Modified
2024-11-21 08:32
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "6708C521-2523-4FFE-8D66-01386DF0FAAF", "versionEndExcluding": "223.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:-:*:*:*:*:*:*", "matchCriteriaId": "E0ADA2C0-4AA2-4FDB-AB71-2C905106A68F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0001:*:*:*:*:*:*", "matchCriteriaId": "619B13A0-ADF3-4CC9-A5BD-6C99AE369D43", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0002:*:*:*:*:*:*", "matchCriteriaId": "E4C4B3EA-853A-4C75-AA5F-319E2802A722", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0003:*:*:*:*:*:*", "matchCriteriaId": "28C04B66-7E6F-49E6-B7A9-E7357ADE5936", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0004:*:*:*:*:*:*", "matchCriteriaId": "99A72C67-00A3-499A-9DDC-73AD29672A08", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0005:*:*:*:*:*:*", "matchCriteriaId": "9C7B34D6-925F-4DB9-8418-962F35FE11C6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0006:*:*:*:*:*:*", "matchCriteriaId": "211C7830-D4B9-4315-BDE8-F108FF6A609C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0007:*:*:*:*:*:*", "matchCriteriaId": "52647713-2F45-4D35-B31A-5BB2E15175EF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0008:*:*:*:*:*:*", "matchCriteriaId": "4378378B-BAEA-4200-9336-936835322DF6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0009:*:*:*:*:*:*", "matchCriteriaId": "57968030-2B5F-41C1-B8B4-2405C84E3A06", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Solid Edge SE2023 (todas las versiones " } ], "id": "CVE-2023-49130", "lastModified": "2024-11-21T08:32:53.767", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-01-09T10:15:19.053", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-824" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-01-09 10:15
Modified
2024-11-21 08:32
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "6708C521-2523-4FFE-8D66-01386DF0FAAF", "versionEndExcluding": "223.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:-:*:*:*:*:*:*", "matchCriteriaId": "E0ADA2C0-4AA2-4FDB-AB71-2C905106A68F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0001:*:*:*:*:*:*", "matchCriteriaId": "619B13A0-ADF3-4CC9-A5BD-6C99AE369D43", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0002:*:*:*:*:*:*", "matchCriteriaId": "E4C4B3EA-853A-4C75-AA5F-319E2802A722", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0003:*:*:*:*:*:*", "matchCriteriaId": "28C04B66-7E6F-49E6-B7A9-E7357ADE5936", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0004:*:*:*:*:*:*", "matchCriteriaId": "99A72C67-00A3-499A-9DDC-73AD29672A08", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0005:*:*:*:*:*:*", "matchCriteriaId": "9C7B34D6-925F-4DB9-8418-962F35FE11C6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0006:*:*:*:*:*:*", "matchCriteriaId": "211C7830-D4B9-4315-BDE8-F108FF6A609C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0007:*:*:*:*:*:*", "matchCriteriaId": "52647713-2F45-4D35-B31A-5BB2E15175EF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0008:*:*:*:*:*:*", "matchCriteriaId": "4378378B-BAEA-4200-9336-936835322DF6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0009:*:*:*:*:*:*", "matchCriteriaId": "57968030-2B5F-41C1-B8B4-2405C84E3A06", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Solid Edge SE2023 (todas las versiones " } ], "id": "CVE-2023-49121", "lastModified": "2024-11-21T08:32:52.500", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-01-09T10:15:16.760", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-122" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:48
Severity ?
3.3 (Low) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted STL file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19428)
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C", "versionEndExcluding": "2210.0002.004", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted STL file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19428)" } ], "id": "CVE-2023-24565", "lastModified": "2024-11-21T07:48:08.330", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 3.3, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 1.4, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:16.223", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:48
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2022 | - | |
siemens | solid_edge_se2022 | maintenance_pack_1 | |
siemens | solid_edge_se2022 | maintenance_pack_2 | |
siemens | solid_edge_se2022 | maintenance_pack_3 | |
siemens | solid_edge_se2022 | maintenance_pack_4 | |
siemens | solid_edge_se2022 | maintenance_pack_5 | |
siemens | solid_edge_se2022 | maintenance_pack_7 | |
siemens | solid_edge_se2022 | maintenance_pack_8 | |
siemens | solid_edge_se2022 | maintenance_pack_9 | |
siemens | solid_edge_se2022 | maintenance_pack_10 | |
siemens | solid_edge_se2022 | maintenance_pack_11 | |
siemens | solid_edge_se2023 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "22C0D3BE-0640-49C8-86F1-52966CABA2E2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_1:*:*:*:*:*:*:*", "matchCriteriaId": "DE12CBDF-222E-4DE9-927A-3BDDBFFF1E1A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_2:*:*:*:*:*:*:*", "matchCriteriaId": "EEFAAAE5-52B1-48EA-98E1-98A854CBE65A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_3:*:*:*:*:*:*:*", "matchCriteriaId": "D5AFCFBB-ED56-4DDB-89D8-B47A20821AB8", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_4:*:*:*:*:*:*:*", "matchCriteriaId": "087A9E78-9E5C-4D94-A251-02F9AB160F54", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_5:*:*:*:*:*:*:*", "matchCriteriaId": "68EE0588-FE7F-4581-9484-52404DB5B99A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_7:*:*:*:*:*:*:*", "matchCriteriaId": "9F72318F-0E9C-4AB1-9CA2-6527513AE0F6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_8:*:*:*:*:*:*:*", "matchCriteriaId": "63C93992-17F7-4499-BC57-BD67E8A6C508", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_9:*:*:*:*:*:*:*", "matchCriteriaId": "7180CEA7-150A-4B1D-BDFD-61C320A33148", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_10:*:*:*:*:*:*:*", "matchCriteriaId": "B0244EE5-BF22-491A-A7DE-48F44E2A17FC", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_11:*:*:*:*:*:*:*", "matchCriteriaId": "3A583AAD-5B13-4822-AA24-AA7D16305FE2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C", "versionEndExcluding": "2210.0002.004", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Solid Edge SE2022 (Todas las versiones \u0026lt; V222.0MP12), Solid Edge SE2023 (Todas las versiones \u0026lt; V223.0Update2). Las aplicaciones afectadas contienen una lectura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada mientras analizan archivos PAR especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual." } ], "id": "CVE-2023-24555", "lastModified": "2024-11-21T07:48:07.037", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:15.393", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:48
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C", "versionEndExcluding": "2210.0002.004", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "id": "CVE-2023-24549", "lastModified": "2024-11-21T07:48:06.317", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:14.880", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-01-09 10:15
Modified
2024-11-21 08:32
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "6708C521-2523-4FFE-8D66-01386DF0FAAF", "versionEndExcluding": "223.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:-:*:*:*:*:*:*", "matchCriteriaId": "E0ADA2C0-4AA2-4FDB-AB71-2C905106A68F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0001:*:*:*:*:*:*", "matchCriteriaId": "619B13A0-ADF3-4CC9-A5BD-6C99AE369D43", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0002:*:*:*:*:*:*", "matchCriteriaId": "E4C4B3EA-853A-4C75-AA5F-319E2802A722", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0003:*:*:*:*:*:*", "matchCriteriaId": "28C04B66-7E6F-49E6-B7A9-E7357ADE5936", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0004:*:*:*:*:*:*", "matchCriteriaId": "99A72C67-00A3-499A-9DDC-73AD29672A08", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0005:*:*:*:*:*:*", "matchCriteriaId": "9C7B34D6-925F-4DB9-8418-962F35FE11C6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0006:*:*:*:*:*:*", "matchCriteriaId": "211C7830-D4B9-4315-BDE8-F108FF6A609C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0007:*:*:*:*:*:*", "matchCriteriaId": "52647713-2F45-4D35-B31A-5BB2E15175EF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0008:*:*:*:*:*:*", "matchCriteriaId": "4378378B-BAEA-4200-9336-936835322DF6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0009:*:*:*:*:*:*", "matchCriteriaId": "57968030-2B5F-41C1-B8B4-2405C84E3A06", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Solid Edge SE2023 (todas las versiones " } ], "id": "CVE-2023-49126", "lastModified": "2024-11-21T08:32:53.220", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-01-09T10:15:17.997", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-12-13 16:15
Modified
2024-11-21 07:30
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | parasolid | * | |
siemens | parasolid | * | |
siemens | parasolid | * | |
siemens | parasolid | * | |
siemens | solid_edge_se2022 | * | |
siemens | solid_edge_se2023 | - | |
siemens | solid_edge_se2023 | 223.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "matchCriteriaId": "F1405366-A402-4908-858D-E844853BE1DA", "versionEndExcluding": "33.1.264", "versionStartIncluding": "33.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "matchCriteriaId": "F0D9079D-6138-4602-A982-9BC4ECBC35E7", "versionEndExcluding": "34.0.252", "versionStartIncluding": "34.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C486991-A1C0-4815-AAD6-163464D711AA", "versionEndExcluding": "34.1.242", "versionStartIncluding": "34.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA2114FD-BB07-4C24-98B1-928A510565BB", "versionEndExcluding": "35.0.170", "versionStartIncluding": "35.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FF17E24-2697-4110-8A0F-BC76BA617C76", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:-:*:*:*:*:*:*:*", "matchCriteriaId": "60B92DC2-5A0D-4F6E-81FD-3A0CA25B0D32", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:-:*:*:*:*:*:*", "matchCriteriaId": "E0ADA2C0-4AA2-4FDB-AB71-2C905106A68F", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)" }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en: \nParasolid V33.1 (Todas las versiones \u0026lt; V33.1.264), \nParasolid V34.0 (Todas las versiones \u0026lt; V34.0.252), \nParasolid V34.1 (Todas las versiones \u0026lt; V34.1.242), \nParasolid V35 .0 (Todas las versiones \u0026lt; V35.0.170), \nSolid Edge SE2022 (Todas las versiones \u0026lt; V222.0MP12), \nSolid Edge SE2022 (Todas las versiones), \nSolid Edge SE2023 (Todas las versiones \u0026lt; V223.0Update2). \nLas aplicaciones afectadas contienen una escritura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada mientras analizan archivos X_B especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-19070)" } ], "id": "CVE-2022-46345", "lastModified": "2024-11-21T07:30:25.770", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2022-12-13T16:15:25.330", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:48
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C", "versionEndExcluding": "2210.0002.004", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "id": "CVE-2023-24562", "lastModified": "2024-11-21T07:48:07.933", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:15.977", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-824" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-01-09 10:15
Modified
2024-11-21 08:32
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain a stack overflow vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "6708C521-2523-4FFE-8D66-01386DF0FAAF", "versionEndExcluding": "223.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:-:*:*:*:*:*:*", "matchCriteriaId": "E0ADA2C0-4AA2-4FDB-AB71-2C905106A68F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0001:*:*:*:*:*:*", "matchCriteriaId": "619B13A0-ADF3-4CC9-A5BD-6C99AE369D43", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0002:*:*:*:*:*:*", "matchCriteriaId": "E4C4B3EA-853A-4C75-AA5F-319E2802A722", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0003:*:*:*:*:*:*", "matchCriteriaId": "28C04B66-7E6F-49E6-B7A9-E7357ADE5936", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0004:*:*:*:*:*:*", "matchCriteriaId": "99A72C67-00A3-499A-9DDC-73AD29672A08", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0005:*:*:*:*:*:*", "matchCriteriaId": "9C7B34D6-925F-4DB9-8418-962F35FE11C6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0006:*:*:*:*:*:*", "matchCriteriaId": "211C7830-D4B9-4315-BDE8-F108FF6A609C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0007:*:*:*:*:*:*", "matchCriteriaId": "52647713-2F45-4D35-B31A-5BB2E15175EF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0008:*:*:*:*:*:*", "matchCriteriaId": "4378378B-BAEA-4200-9336-936835322DF6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0009:*:*:*:*:*:*", "matchCriteriaId": "57968030-2B5F-41C1-B8B4-2405C84E3A06", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected applications contain a stack overflow vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Solid Edge SE2023 (todas las versiones " } ], "id": "CVE-2023-49129", "lastModified": "2024-11-21T08:32:53.633", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-01-09T10:15:18.743", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-01-09 10:15
Modified
2024-11-21 08:32
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "6708C521-2523-4FFE-8D66-01386DF0FAAF", "versionEndExcluding": "223.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:-:*:*:*:*:*:*", "matchCriteriaId": "E0ADA2C0-4AA2-4FDB-AB71-2C905106A68F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0001:*:*:*:*:*:*", "matchCriteriaId": "619B13A0-ADF3-4CC9-A5BD-6C99AE369D43", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0002:*:*:*:*:*:*", "matchCriteriaId": "E4C4B3EA-853A-4C75-AA5F-319E2802A722", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0003:*:*:*:*:*:*", "matchCriteriaId": "28C04B66-7E6F-49E6-B7A9-E7357ADE5936", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0004:*:*:*:*:*:*", "matchCriteriaId": "99A72C67-00A3-499A-9DDC-73AD29672A08", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0005:*:*:*:*:*:*", "matchCriteriaId": "9C7B34D6-925F-4DB9-8418-962F35FE11C6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0006:*:*:*:*:*:*", "matchCriteriaId": "211C7830-D4B9-4315-BDE8-F108FF6A609C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0007:*:*:*:*:*:*", "matchCriteriaId": "52647713-2F45-4D35-B31A-5BB2E15175EF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0008:*:*:*:*:*:*", "matchCriteriaId": "4378378B-BAEA-4200-9336-936835322DF6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0009:*:*:*:*:*:*", "matchCriteriaId": "57968030-2B5F-41C1-B8B4-2405C84E3A06", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Solid Edge SE2023 (todas las versiones " } ], "id": "CVE-2023-49128", "lastModified": "2024-11-21T08:32:53.507", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-01-09T10:15:18.520", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:48
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains a memory corruption vulnerability while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19069)
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C", "versionEndExcluding": "2210.0002.004", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application contains a memory corruption vulnerability while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19069)" } ], "id": "CVE-2023-24564", "lastModified": "2024-11-21T07:48:08.210", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:16.137", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-05-09 13:15
Modified
2024-11-21 08:01
Severity ?
3.3 (Low) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 3), Solid Edge SE2023 (All versions < V223.0 Update 2). Affected applications contain an out of bounds read past the end of an allocated buffer while parsing a specially crafted OBJ file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19426)
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | - | |
siemens | solid_edge_se2023 | update_0001 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:-:*:*:*:*:*:*:*", "matchCriteriaId": "60B92DC2-5A0D-4F6E-81FD-3A0CA25B0D32", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:update_0001:*:*:*:*:*:*:*", "matchCriteriaId": "E10B6B37-8C69-47B6-A4B8-DDBA562F083E", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 3), Solid Edge SE2023 (All versions \u003c V223.0 Update 2). Affected applications contain an out of bounds read past the end of an allocated buffer while parsing a specially crafted OBJ file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19426)" } ], "id": "CVE-2023-30985", "lastModified": "2024-11-21T08:01:11.153", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 3.3, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 1.4, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-05-09T13:15:18.267", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-932528.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-932528.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-01-09 10:15
Modified
2024-11-21 08:32
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "6708C521-2523-4FFE-8D66-01386DF0FAAF", "versionEndExcluding": "223.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:-:*:*:*:*:*:*", "matchCriteriaId": "E0ADA2C0-4AA2-4FDB-AB71-2C905106A68F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0001:*:*:*:*:*:*", "matchCriteriaId": "619B13A0-ADF3-4CC9-A5BD-6C99AE369D43", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0002:*:*:*:*:*:*", "matchCriteriaId": "E4C4B3EA-853A-4C75-AA5F-319E2802A722", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0003:*:*:*:*:*:*", "matchCriteriaId": "28C04B66-7E6F-49E6-B7A9-E7357ADE5936", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0004:*:*:*:*:*:*", "matchCriteriaId": "99A72C67-00A3-499A-9DDC-73AD29672A08", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0005:*:*:*:*:*:*", "matchCriteriaId": "9C7B34D6-925F-4DB9-8418-962F35FE11C6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0006:*:*:*:*:*:*", "matchCriteriaId": "211C7830-D4B9-4315-BDE8-F108FF6A609C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0007:*:*:*:*:*:*", "matchCriteriaId": "52647713-2F45-4D35-B31A-5BB2E15175EF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0008:*:*:*:*:*:*", "matchCriteriaId": "4378378B-BAEA-4200-9336-936835322DF6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0009:*:*:*:*:*:*", "matchCriteriaId": "57968030-2B5F-41C1-B8B4-2405C84E3A06", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Solid Edge SE2023 (todas las versiones " } ], "id": "CVE-2023-49127", "lastModified": "2024-11-21T08:32:53.380", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-01-09T10:15:18.230", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-01-09 10:15
Modified
2024-11-21 08:32
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "6708C521-2523-4FFE-8D66-01386DF0FAAF", "versionEndExcluding": "223.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:-:*:*:*:*:*:*", "matchCriteriaId": "E0ADA2C0-4AA2-4FDB-AB71-2C905106A68F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0001:*:*:*:*:*:*", "matchCriteriaId": "619B13A0-ADF3-4CC9-A5BD-6C99AE369D43", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0002:*:*:*:*:*:*", "matchCriteriaId": "E4C4B3EA-853A-4C75-AA5F-319E2802A722", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0003:*:*:*:*:*:*", "matchCriteriaId": "28C04B66-7E6F-49E6-B7A9-E7357ADE5936", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0004:*:*:*:*:*:*", "matchCriteriaId": "99A72C67-00A3-499A-9DDC-73AD29672A08", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0005:*:*:*:*:*:*", "matchCriteriaId": "9C7B34D6-925F-4DB9-8418-962F35FE11C6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0006:*:*:*:*:*:*", "matchCriteriaId": "211C7830-D4B9-4315-BDE8-F108FF6A609C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0007:*:*:*:*:*:*", "matchCriteriaId": "52647713-2F45-4D35-B31A-5BB2E15175EF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0008:*:*:*:*:*:*", "matchCriteriaId": "4378378B-BAEA-4200-9336-936835322DF6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0009:*:*:*:*:*:*", "matchCriteriaId": "57968030-2B5F-41C1-B8B4-2405C84E3A06", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Solid Edge SE2023 (todas las versiones " } ], "id": "CVE-2023-49132", "lastModified": "2024-11-21T08:32:54.053", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-01-09T10:15:19.637", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-824" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:48
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C", "versionEndExcluding": "2210.0002.004", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "id": "CVE-2023-24558", "lastModified": "2024-11-21T07:48:07.427", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:15.643", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:48
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C", "versionEndExcluding": "2210.0002.004", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "id": "CVE-2023-24561", "lastModified": "2024-11-21T07:48:07.800", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:15.893", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-824" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:48
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C", "versionEndExcluding": "2210.0002.004", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "id": "CVE-2023-24554", "lastModified": "2024-11-21T07:48:06.923", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:15.307", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:48
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to heap-based buffer underflow while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C", "versionEndExcluding": "2210.0002.004", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application is vulnerable to heap-based buffer underflow while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "id": "CVE-2023-24551", "lastModified": "2024-11-21T07:48:06.557", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:15.053", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-122" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-01-09 10:15
Modified
2024-11-21 08:32
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "6708C521-2523-4FFE-8D66-01386DF0FAAF", "versionEndExcluding": "223.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:-:*:*:*:*:*:*", "matchCriteriaId": "E0ADA2C0-4AA2-4FDB-AB71-2C905106A68F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0001:*:*:*:*:*:*", "matchCriteriaId": "619B13A0-ADF3-4CC9-A5BD-6C99AE369D43", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0002:*:*:*:*:*:*", "matchCriteriaId": "E4C4B3EA-853A-4C75-AA5F-319E2802A722", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0003:*:*:*:*:*:*", "matchCriteriaId": "28C04B66-7E6F-49E6-B7A9-E7357ADE5936", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0004:*:*:*:*:*:*", "matchCriteriaId": "99A72C67-00A3-499A-9DDC-73AD29672A08", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0005:*:*:*:*:*:*", "matchCriteriaId": "9C7B34D6-925F-4DB9-8418-962F35FE11C6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0006:*:*:*:*:*:*", "matchCriteriaId": "211C7830-D4B9-4315-BDE8-F108FF6A609C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0007:*:*:*:*:*:*", "matchCriteriaId": "52647713-2F45-4D35-B31A-5BB2E15175EF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0008:*:*:*:*:*:*", "matchCriteriaId": "4378378B-BAEA-4200-9336-936835322DF6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0009:*:*:*:*:*:*", "matchCriteriaId": "57968030-2B5F-41C1-B8B4-2405C84E3A06", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Solid Edge SE2023 (todas las versiones " } ], "id": "CVE-2023-49124", "lastModified": "2024-11-21T08:32:52.927", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-01-09T10:15:17.693", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-02-13 09:15
Modified
2024-11-21 08:32
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.263), Parasolid V35.1 (All versions < V35.1.252), Parasolid V36.0 (All versions < V36.0.198), Solid Edge SE2023 (All versions < V223.0 Update 11), Solid Edge SE2024 (All versions < V224.0 Update 3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted files containing XT format. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | parasolid | * | |
siemens | parasolid | * | |
siemens | parasolid | * | |
siemens | solid_edge_se2023 | * | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2024 | * | |
siemens | solid_edge_se2024 | 224.0 | |
siemens | solid_edge_se2024 | 224.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E918719-9972-41B1-88FE-F37A1B73926C", "versionEndExcluding": "35.0.263", "versionStartIncluding": "35.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "matchCriteriaId": "0A867E95-E661-42EA-8E58-973EBC559806", "versionEndExcluding": "35.1.252", "versionStartIncluding": "35.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "matchCriteriaId": "61E012B9-DD01-4F8C-B8EB-EBE5BD50EA82", "versionEndExcluding": "36.0.198", "versionStartIncluding": "36.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "6708C521-2523-4FFE-8D66-01386DF0FAAF", "versionEndExcluding": "223.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0001:*:*:*:*:*:*", "matchCriteriaId": "619B13A0-ADF3-4CC9-A5BD-6C99AE369D43", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0002:*:*:*:*:*:*", "matchCriteriaId": "E4C4B3EA-853A-4C75-AA5F-319E2802A722", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0003:*:*:*:*:*:*", "matchCriteriaId": "28C04B66-7E6F-49E6-B7A9-E7357ADE5936", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0004:*:*:*:*:*:*", "matchCriteriaId": "99A72C67-00A3-499A-9DDC-73AD29672A08", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0005:*:*:*:*:*:*", "matchCriteriaId": "9C7B34D6-925F-4DB9-8418-962F35FE11C6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0006:*:*:*:*:*:*", "matchCriteriaId": "211C7830-D4B9-4315-BDE8-F108FF6A609C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0007:*:*:*:*:*:*", "matchCriteriaId": "52647713-2F45-4D35-B31A-5BB2E15175EF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0008:*:*:*:*:*:*", "matchCriteriaId": "4378378B-BAEA-4200-9336-936835322DF6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0009:*:*:*:*:*:*", "matchCriteriaId": "57968030-2B5F-41C1-B8B4-2405C84E3A06", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0010:*:*:*:*:*:*", "matchCriteriaId": "BB884C55-636D-4DED-8865-CA83CC74FE05", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2024:*:*:*:*:*:*:*:*", "matchCriteriaId": "D3887095-4E46-43B0-8A1E-4938EB474419", "versionEndExcluding": "224.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0001:*:*:*:*:*:*", "matchCriteriaId": "829C4AEB-7C8D-408B-A79C-8684753F45E1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0002:*:*:*:*:*:*", "matchCriteriaId": "1E8FB23E-280D-46FD-BD44-5D4552639E00", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Parasolid V35.0 (All versions \u003c V35.0.263), Parasolid V35.1 (All versions \u003c V35.1.252), Parasolid V36.0 (All versions \u003c V36.0.198), Solid Edge SE2023 (All versions \u003c V223.0 Update 11), Solid Edge SE2024 (All versions \u003c V224.0 Update 3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted files containing XT format. This could allow an attacker to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Parasolid V35.0 (Todas las versiones \u0026lt; V35.0.263), Parasolid V35.1 (Todas las versiones \u0026lt; V35.1.252), Parasolid V36.0 (Todas las versiones \u0026lt; V36.0.198). Las aplicaciones afectadas contienen una lectura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada mientras analizan archivos especialmente manipulados que contienen formato XT. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual." } ], "id": "CVE-2023-49125", "lastModified": "2024-11-21T08:32:53.063", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-02-13T09:15:46.173", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-382651.html" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-797296.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-382651.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-797296.html" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-08 10:15
Modified
2024-11-21 07:56
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in JT2Go (All versions < V14.2.0.5), Solid Edge SE2022 (All versions < V222.0 Update 13), Solid Edge SE2023 (All versions < V223.0 Update 4), Teamcenter Visualization V13.2 (All versions < V13.2.0.15), Teamcenter Visualization V13.3 (All versions < V13.3.0.11), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.5). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted ASM file. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | jt2go | * | |
siemens | teamcenter_visualization | * | |
siemens | teamcenter_visualization | * | |
siemens | teamcenter_visualization | * | |
siemens | teamcenter_visualization | * | |
siemens | solid_edge_se2022 | - | |
siemens | solid_edge_se2022 | maintenance_pack_1 | |
siemens | solid_edge_se2022 | maintenance_pack_2 | |
siemens | solid_edge_se2022 | maintenance_pack_3 | |
siemens | solid_edge_se2022 | maintenance_pack_4 | |
siemens | solid_edge_se2022 | maintenance_pack_5 | |
siemens | solid_edge_se2022 | maintenance_pack_7 | |
siemens | solid_edge_se2022 | maintenance_pack_8 | |
siemens | solid_edge_se2022 | maintenance_pack_9 | |
siemens | solid_edge_se2022 | maintenance_pack_10 | |
siemens | solid_edge_se2022 | maintenance_pack_11 | |
siemens | solid_edge_se2022 | maintenance_pack_12 | |
siemens | solid_edge_se2023 | - | |
siemens | solid_edge_se2023 | update_0001 | |
siemens | solid_edge_se2023 | update_0002 | |
siemens | solid_edge_se2023 | update_0003 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "matchCriteriaId": "52B9AF54-6EAC-4333-932B-7DD2F00CEDCE", "versionEndExcluding": "14.2.0.5", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "matchCriteriaId": "B51820E2-ED58-4CF9-9141-9875185E5034", "versionEndExcluding": "13.2.0.15", "versionStartIncluding": "13.2.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "matchCriteriaId": "677E517E-AF71-4D17-8200-F46545800581", "versionEndExcluding": "13.3.0.11", "versionStartIncluding": "13.3.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "matchCriteriaId": "9EF3388B-D057-4DB9-96AE-B6F4678FE5B8", "versionEndExcluding": "14.1.0.11", "versionStartIncluding": "14.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "matchCriteriaId": "B2FB1524-FFB8-4190-A221-248509EC6756", "versionEndExcluding": "14.2.0.5", "versionStartIncluding": "14.2", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "22C0D3BE-0640-49C8-86F1-52966CABA2E2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_1:*:*:*:*:*:*:*", "matchCriteriaId": "DE12CBDF-222E-4DE9-927A-3BDDBFFF1E1A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_2:*:*:*:*:*:*:*", "matchCriteriaId": "EEFAAAE5-52B1-48EA-98E1-98A854CBE65A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_3:*:*:*:*:*:*:*", "matchCriteriaId": "D5AFCFBB-ED56-4DDB-89D8-B47A20821AB8", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_4:*:*:*:*:*:*:*", "matchCriteriaId": "087A9E78-9E5C-4D94-A251-02F9AB160F54", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_5:*:*:*:*:*:*:*", "matchCriteriaId": "68EE0588-FE7F-4581-9484-52404DB5B99A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_7:*:*:*:*:*:*:*", "matchCriteriaId": "9F72318F-0E9C-4AB1-9CA2-6527513AE0F6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_8:*:*:*:*:*:*:*", "matchCriteriaId": "63C93992-17F7-4499-BC57-BD67E8A6C508", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_9:*:*:*:*:*:*:*", "matchCriteriaId": "7180CEA7-150A-4B1D-BDFD-61C320A33148", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_10:*:*:*:*:*:*:*", "matchCriteriaId": "B0244EE5-BF22-491A-A7DE-48F44E2A17FC", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_11:*:*:*:*:*:*:*", "matchCriteriaId": "3A583AAD-5B13-4822-AA24-AA7D16305FE2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_12:*:*:*:*:*:*:*", "matchCriteriaId": "543549E2-CD73-48ED-8BB3-2BAC721A850C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:-:*:*:*:*:*:*:*", "matchCriteriaId": "60B92DC2-5A0D-4F6E-81FD-3A0CA25B0D32", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:update_0001:*:*:*:*:*:*:*", "matchCriteriaId": "E10B6B37-8C69-47B6-A4B8-DDBA562F083E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:update_0002:*:*:*:*:*:*:*", "matchCriteriaId": "FB3FFA6A-3A27-4F38-9A4B-E869880A1861", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:update_0003:*:*:*:*:*:*:*", "matchCriteriaId": "C35655ED-9061-4674-9321-1485AABBCE06", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.2.0.5), Solid Edge SE2022 (All versions \u003c V222.0 Update 13), Solid Edge SE2023 (All versions \u003c V223.0 Update 4), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.15), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.11), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.5). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted ASM file. An attacker could leverage this vulnerability to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones inferiores a V14.2.0.5), Solid Edge SE2022 (Todas las versiones inferiores a V222.0 Update 13), Solid Edge SE2023 (Todas las versiones inferiores a V223.0 Update 4), Teamcenter Visualization V13. 2 (Todas las versiones inferiores a V13.2.0.15), Teamcenter Visualization V13.3 (Todas las versiones inferiores a V13.3.0.11), Teamcenter Visualization V14.1 (Todas las versiones inferiores a V14.1.0.11), Teamcenter Visualization V14.2 (Todas las versiones inferiores a V14.2.0.5). La aplicaci\u00f3n afectada contiene una vulnerabilidad \"use-after-free\" que podr\u00eda activarse al analizar un archivo ASM especialmente dise\u00f1ado. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual." } ], "id": "CVE-2023-28830", "lastModified": "2024-11-21T07:56:06.480", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-08T10:15:14.847", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-131450.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-131450.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-416" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-416" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:48
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C", "versionEndExcluding": "2210.0002.004", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process." } ], "id": "CVE-2023-24560", "lastModified": "2024-11-21T07:48:07.673", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:15.810", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:48
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C", "versionEndExcluding": "2210.0002.004", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "id": "CVE-2023-24563", "lastModified": "2024-11-21T07:48:08.080", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:16.057", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-824" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:48
Severity ?
3.3 (Low) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19472)
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C", "versionEndExcluding": "2210.0002.004", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19472)" } ], "id": "CVE-2023-24566", "lastModified": "2024-11-21T07:48:08.453", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 3.3, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 1.4, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:16.307", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:48
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C", "versionEndExcluding": "2210.0002.004", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "id": "CVE-2023-24553", "lastModified": "2024-11-21T07:48:06.800", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:15.223", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-01-09 10:15
Modified
2024-11-21 08:32
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 | |
siemens | solid_edge_se2023 | 223.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "6708C521-2523-4FFE-8D66-01386DF0FAAF", "versionEndExcluding": "223.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:-:*:*:*:*:*:*", "matchCriteriaId": "E0ADA2C0-4AA2-4FDB-AB71-2C905106A68F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0001:*:*:*:*:*:*", "matchCriteriaId": "619B13A0-ADF3-4CC9-A5BD-6C99AE369D43", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0002:*:*:*:*:*:*", "matchCriteriaId": "E4C4B3EA-853A-4C75-AA5F-319E2802A722", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0003:*:*:*:*:*:*", "matchCriteriaId": "28C04B66-7E6F-49E6-B7A9-E7357ADE5936", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0004:*:*:*:*:*:*", "matchCriteriaId": "99A72C67-00A3-499A-9DDC-73AD29672A08", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0005:*:*:*:*:*:*", "matchCriteriaId": "9C7B34D6-925F-4DB9-8418-962F35FE11C6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0006:*:*:*:*:*:*", "matchCriteriaId": "211C7830-D4B9-4315-BDE8-F108FF6A609C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0007:*:*:*:*:*:*", "matchCriteriaId": "52647713-2F45-4D35-B31A-5BB2E15175EF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0008:*:*:*:*:*:*", "matchCriteriaId": "4378378B-BAEA-4200-9336-936835322DF6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0009:*:*:*:*:*:*", "matchCriteriaId": "57968030-2B5F-41C1-B8B4-2405C84E3A06", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Solid Edge SE2023 (todas las versiones " } ], "id": "CVE-2023-49122", "lastModified": "2024-11-21T08:32:52.653", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-01-09T10:15:17.127", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-122" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:48
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted STP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19425)
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C", "versionEndExcluding": "2210.0002.004", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted STP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19425)" } ], "id": "CVE-2023-24581", "lastModified": "2024-11-21T07:48:10.390", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:16.387", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-416" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:48
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C", "versionEndExcluding": "2210.0002.004", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "id": "CVE-2023-24556", "lastModified": "2024-11-21T07:48:07.173", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:15.483", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:48
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C", "versionEndExcluding": "2210.0002.004", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "id": "CVE-2023-24559", "lastModified": "2024-11-21T07:48:07.550", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:15.723", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-05-09 13:15
Modified
2024-11-21 08:01
Severity ?
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 3), Solid Edge SE2023 (All versions < V223.0 Update 2). Affected applications contain a memory corruption vulnerability while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19561)
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge_se2023 | - | |
siemens | solid_edge_se2023 | update_0001 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:-:*:*:*:*:*:*:*", "matchCriteriaId": "60B92DC2-5A0D-4F6E-81FD-3A0CA25B0D32", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:update_0001:*:*:*:*:*:*:*", "matchCriteriaId": "E10B6B37-8C69-47B6-A4B8-DDBA562F083E", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 3), Solid Edge SE2023 (All versions \u003c V223.0 Update 2). Affected applications contain a memory corruption vulnerability while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19561)" } ], "id": "CVE-2023-30986", "lastModified": "2024-11-21T08:01:11.280", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" } ] }, "published": "2023-05-09T13:15:18.350", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-932528.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-932528.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
cve-2023-28830
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2024-10-23 19:49
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.2.0.5), Solid Edge SE2022 (All versions < V222.0 Update 13), Solid Edge SE2023 (All versions < V223.0 Update 4), Teamcenter Visualization V13.2 (All versions < V13.2.0.15), Teamcenter Visualization V13.3 (All versions < V13.3.0.11), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.5). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted ASM file. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | JT2Go |
Version: All versions < V14.2.0.5 |
||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T13:51:38.123Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-131450.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-28830", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-23T19:48:40.205775Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-23T19:49:54.534Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "JT2Go", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14.2.0.5" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0 Update 13" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0 Update 4" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V13.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13.2.0.15" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V13.3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13.3.0.11" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14.1.0.11" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14.2.0.5" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.2.0.5), Solid Edge SE2022 (All versions \u003c V222.0 Update 13), Solid Edge SE2023 (All versions \u003c V223.0 Update 4), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.15), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.11), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.5). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted ASM file. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-416", "description": "CWE-416: Use After Free", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-08T09:20:17.760Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-131450.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-28830", "datePublished": "2023-08-08T09:20:17.760Z", "dateReserved": "2023-03-24T15:17:33.934Z", "dateUpdated": "2024-10-23T19:49:54.534Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-24552
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2022 |
Version: All versions < V222.0MP12 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:03:18.800Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:19.249Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-24552", "datePublished": "2023-02-14T10:36:29.146Z", "dateReserved": "2023-01-26T14:06:35.399Z", "dateUpdated": "2024-08-02T11:03:18.800Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49125
Vulnerability from cvelistv5
Published
2024-02-13 08:59
Modified
2024-08-02 21:46
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.263), Parasolid V35.1 (All versions < V35.1.252), Parasolid V36.0 (All versions < V36.0.198), Solid Edge SE2023 (All versions < V223.0 Update 11), Solid Edge SE2024 (All versions < V224.0 Update 3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted files containing XT format. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Parasolid V35.0 |
Version: 0 < V35.0.263 |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:46:29.325Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-797296.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-382651.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Parasolid V35.0", "vendor": "Siemens", "versions": [ { "lessThan": "V35.0.263", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V35.1", "vendor": "Siemens", "versions": [ { "lessThan": "V35.1.252", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V36.0", "vendor": "Siemens", "versions": [ { "lessThan": "V36.0.198", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "lessThan": "V223.0 Update 11", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2024", "vendor": "Siemens", "versions": [ { "lessThan": "V224.0 Update 3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Parasolid V35.0 (All versions \u003c V35.0.263), Parasolid V35.1 (All versions \u003c V35.1.252), Parasolid V36.0 (All versions \u003c V36.0.198), Solid Edge SE2023 (All versions \u003c V223.0 Update 11), Solid Edge SE2024 (All versions \u003c V224.0 Update 3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted files containing XT format. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-15T07:23:49.243Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-797296.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-382651.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-49125", "datePublished": "2024-02-13T08:59:57.813Z", "dateReserved": "2023-11-22T14:43:13.524Z", "dateUpdated": "2024-08-02T21:46:29.325Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-24561
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2022 |
Version: All versions < V222.0MP12 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:03:18.698Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-824", "description": "CWE-824: Access of Uninitialized Pointer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:28.643Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-24561", "datePublished": "2023-02-14T10:36:39.446Z", "dateReserved": "2023-01-26T14:06:35.401Z", "dateUpdated": "2024-08-02T11:03:18.698Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49123
Vulnerability from cvelistv5
Published
2024-01-09 09:59
Modified
2024-08-02 21:46
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens | Solid Edge SE2023 |
Version: All versions < V223.0 Update 10 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:46:29.183Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0 Update 10" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122: Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-09T09:59:55.117Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-49123", "datePublished": "2024-01-09T09:59:55.117Z", "dateReserved": "2023-11-22T14:43:13.524Z", "dateUpdated": "2024-08-02T21:46:29.183Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-24550
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to heap-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2022 |
Version: All versions < V222.0MP12 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:03:18.837Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application is vulnerable to heap-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122: Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:17.103Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-24550", "datePublished": "2023-02-14T10:36:26.898Z", "dateReserved": "2023-01-26T14:06:35.398Z", "dateUpdated": "2024-08-02T11:03:18.837Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-24558
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2022 |
Version: All versions < V222.0MP12 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:03:18.772Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:25.558Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-24558", "datePublished": "2023-02-14T10:36:36.036Z", "dateReserved": "2023-01-26T14:06:35.400Z", "dateUpdated": "2024-08-02T11:03:18.772Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-24566
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19472)
References
Impacted products
Vendor | Product | Version | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2022 |
Version: All versions < V222.0MP12 |
||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:03:19.234Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19472)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121: Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:33.773Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-24566", "datePublished": "2023-02-14T10:36:45.233Z", "dateReserved": "2023-01-26T16:20:20.792Z", "dateUpdated": "2024-08-02T11:03:19.234Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49126
Vulnerability from cvelistv5
Published
2024-01-09 09:59
Modified
2024-08-02 21:46
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens | Solid Edge SE2023 |
Version: All versions < V223.0 Update 10 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:46:29.128Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0 Update 10" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-09T09:59:57.599Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-49126", "datePublished": "2024-01-09T09:59:57.599Z", "dateReserved": "2023-11-22T14:50:33.102Z", "dateUpdated": "2024-08-02T21:46:29.128Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-24560
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2022 |
Version: All versions < V222.0MP12 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:03:18.954Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787: Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:27.615Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-24560", "datePublished": "2023-02-14T10:36:38.321Z", "dateReserved": "2023-01-26T14:06:35.401Z", "dateUpdated": "2024-08-02T11:03:18.954Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49132
Vulnerability from cvelistv5
Published
2024-01-09 10:00
Modified
2024-08-02 21:46
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens | Solid Edge SE2023 |
Version: All versions < V223.0 Update 10 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:46:28.963Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0 Update 10" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-824", "description": "CWE-824: Access of Uninitialized Pointer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-09T10:00:07.440Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-49132", "datePublished": "2024-01-09T10:00:07.440Z", "dateReserved": "2023-11-22T14:53:05.160Z", "dateUpdated": "2024-08-02T21:46:28.963Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-24557
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2022 |
Version: All versions < V222.0MP12 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:03:18.831Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:24.502Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-24557", "datePublished": "2023-02-14T10:36:34.877Z", "dateReserved": "2023-01-26T14:06:35.400Z", "dateUpdated": "2024-08-02T11:03:18.831Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-24556
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2022 |
Version: All versions < V222.0MP12 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:03:19.254Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:23.467Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-24556", "datePublished": "2023-02-14T10:36:33.749Z", "dateReserved": "2023-01-26T14:06:35.400Z", "dateUpdated": "2024-08-02T11:03:19.254Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49127
Vulnerability from cvelistv5
Published
2024-01-09 09:59
Modified
2024-08-02 21:46
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens | Solid Edge SE2023 |
Version: All versions < V223.0 Update 10 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:46:29.207Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0 Update 10" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-09T09:59:58.842Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-49127", "datePublished": "2024-01-09T09:59:58.842Z", "dateReserved": "2023-11-22T14:50:33.103Z", "dateUpdated": "2024-08-02T21:46:29.207Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-24559
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2022 |
Version: All versions < V222.0MP12 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:03:19.031Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:26.597Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-24559", "datePublished": "2023-02-14T10:36:37.176Z", "dateReserved": "2023-01-26T14:06:35.401Z", "dateUpdated": "2024-08-02T11:03:19.031Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49130
Vulnerability from cvelistv5
Published
2024-01-09 10:00
Modified
2024-08-02 21:46
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens | Solid Edge SE2023 |
Version: All versions < V223.0 Update 10 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:46:29.185Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0 Update 10" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-824", "description": "CWE-824: Access of Uninitialized Pointer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-09T10:00:04.164Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-49130", "datePublished": "2024-01-09T10:00:04.164Z", "dateReserved": "2023-11-22T14:50:33.103Z", "dateUpdated": "2024-08-02T21:46:29.185Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49129
Vulnerability from cvelistv5
Published
2024-01-09 10:00
Modified
2024-08-02 21:46
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain a stack overflow vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens | Solid Edge SE2023 |
Version: All versions < V223.0 Update 10 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:46:29.222Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0 Update 10" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected applications contain a stack overflow vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121: Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-09T10:00:02.399Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-49129", "datePublished": "2024-01-09T10:00:02.399Z", "dateReserved": "2023-11-22T14:50:33.103Z", "dateUpdated": "2024-08-02T21:46:29.222Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-30986
Vulnerability from cvelistv5
Published
2023-05-09 11:51
Modified
2025-01-28 17:32
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 3), Solid Edge SE2023 (All versions < V223.0 Update 2). Affected applications contain a memory corruption vulnerability while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19561)
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2023 |
Version: All versions < V223.0 Update 3 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:45:24.421Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-932528.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-30986", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-28T17:32:18.487767Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-28T17:32:32.110Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0 Update 3" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0 Update 2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 3), Solid Edge SE2023 (All versions \u003c V223.0 Update 2). Affected applications contain a memory corruption vulnerability while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19561)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-119", "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-08T09:20:23.259Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-932528.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-30986", "datePublished": "2023-05-09T11:51:39.689Z", "dateReserved": "2023-04-21T15:30:43.319Z", "dateUpdated": "2025-01-28T17:32:32.110Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-24551
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to heap-based buffer underflow while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2022 |
Version: All versions < V222.0MP12 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:03:18.796Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application is vulnerable to heap-based buffer underflow while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122: Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:18.230Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-24551", "datePublished": "2023-02-14T10:36:28.028Z", "dateReserved": "2023-01-26T14:06:35.399Z", "dateUpdated": "2024-08-02T11:03:18.796Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-24565
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted STL file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19428)
References
Impacted products
Vendor | Product | Version | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2022 |
Version: All versions < V222.0MP12 |
||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:03:18.646Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted STL file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19428)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:32.753Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-24565", "datePublished": "2023-02-14T10:36:44.102Z", "dateReserved": "2023-01-26T16:20:20.792Z", "dateUpdated": "2024-08-02T11:03:18.646Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-24581
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted STP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19425)
References
Impacted products
Vendor | Product | Version | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2022 |
Version: All versions < V222.0MP12 |
||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:03:18.775Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted STP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19425)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-416", "description": "CWE-416: Use After Free", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:34.788Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-24581", "datePublished": "2023-02-14T10:36:46.345Z", "dateReserved": "2023-01-27T16:12:53.048Z", "dateUpdated": "2024-08-02T11:03:18.775Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49121
Vulnerability from cvelistv5
Published
2024-01-09 09:59
Modified
2024-08-02 21:46
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens | Solid Edge SE2023 |
Version: All versions < V223.0 Update 10 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:46:29.230Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0 Update 10" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122: Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-09T09:59:52.512Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-49121", "datePublished": "2024-01-09T09:59:52.512Z", "dateReserved": "2023-11-22T14:43:13.523Z", "dateUpdated": "2024-08-02T21:46:29.230Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-24564
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains a memory corruption vulnerability while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19069)
References
Impacted products
Vendor | Product | Version | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2022 |
Version: All versions < V222.0MP12 |
||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:03:18.737Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application contains a memory corruption vulnerability while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19069)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-119", "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:31.708Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-24564", "datePublished": "2023-02-14T10:36:43.008Z", "dateReserved": "2023-01-26T16:20:20.791Z", "dateUpdated": "2024-08-02T11:03:18.737Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-24554
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2022 |
Version: All versions < V222.0MP12 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:03:18.903Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:21.336Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-24554", "datePublished": "2023-02-14T10:36:31.375Z", "dateReserved": "2023-01-26T14:06:35.399Z", "dateUpdated": "2024-08-02T11:03:18.903Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-24563
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2022 |
Version: All versions < V222.0MP12 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:03:18.669Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-824", "description": "CWE-824: Access of Uninitialized Pointer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:30.687Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-24563", "datePublished": "2023-02-14T10:36:41.883Z", "dateReserved": "2023-01-26T14:06:35.401Z", "dateUpdated": "2024-08-02T11:03:18.669Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49131
Vulnerability from cvelistv5
Published
2024-01-09 10:00
Modified
2024-08-02 21:46
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens | Solid Edge SE2023 |
Version: All versions < V223.0 Update 10 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:46:29.145Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0 Update 10" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-824", "description": "CWE-824: Access of Uninitialized Pointer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-09T10:00:05.693Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-49131", "datePublished": "2024-01-09T10:00:05.693Z", "dateReserved": "2023-11-22T14:53:05.160Z", "dateUpdated": "2024-08-02T21:46:29.145Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-24555
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2022 |
Version: All versions < V222.0MP12 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:03:19.248Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:22.404Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-24555", "datePublished": "2023-02-14T10:36:32.550Z", "dateReserved": "2023-01-26T14:06:35.400Z", "dateUpdated": "2024-08-02T11:03:19.248Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-30985
Vulnerability from cvelistv5
Published
2023-05-09 11:51
Modified
2025-01-28 16:46
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 3), Solid Edge SE2023 (All versions < V223.0 Update 2). Affected applications contain an out of bounds read past the end of an allocated buffer while parsing a specially crafted OBJ file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19426)
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2023 |
Version: All versions < V223.0 Update 3 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:45:24.397Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-932528.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-30985", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-01-28T16:46:44.139930Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-28T16:46:48.235Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0 Update 3" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0 Update 2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 3), Solid Edge SE2023 (All versions \u003c V223.0 Update 2). Affected applications contain an out of bounds read past the end of an allocated buffer while parsing a specially crafted OBJ file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19426)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-08T09:20:22.154Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-932528.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-30985", "datePublished": "2023-05-09T11:51:38.608Z", "dateReserved": "2023-04-21T15:30:43.319Z", "dateUpdated": "2025-01-28T16:46:48.235Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-24553
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2022 |
Version: All versions < V222.0MP12 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:03:18.686Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:20.298Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-24553", "datePublished": "2023-02-14T10:36:30.258Z", "dateReserved": "2023-01-26T14:06:35.399Z", "dateUpdated": "2024-08-02T11:03:18.686Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-46345
Vulnerability from cvelistv5
Published
2022-12-13 00:00
Modified
2024-08-03 14:31
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Parasolid V33.1 |
Version: All versions < V33.1.264 |
||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:parasolid:33.1:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "parasolid", "vendor": "siemens", "versions": [ { "lessThan": "33.1.264", "status": "affected", "version": "33.1", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:solid_edge:se2022:-:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "solid_edge", "vendor": "siemens", "versions": [ { "lessThan": "v223.0", "status": "affected", "version": "se2022", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:parasolid:34.1:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "parasolid", "vendor": "siemens", "versions": [ { "lessThan": "34.1.242", "status": "affected", "version": "34.1", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:parasolid:35.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "parasolid", "vendor": "siemens", "versions": [ { "lessThan": "35.0.170", "status": "affected", "version": "35.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:parasolid:34.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "parasolid", "vendor": "siemens", "versions": [ { "lessThan": "34.0.252", "status": "affected", "version": "34.0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2022-46345", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-05-14T13:00:20.745055Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-05T19:22:59.367Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-03T14:31:46.241Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Parasolid V33.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V33.1.264" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V34.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V34.0.252" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V34.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V34.1.242" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V35.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V35.0.170" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787: Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:10.275Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-46345", "datePublished": "2022-12-13T00:00:00", "dateReserved": "2022-11-30T00:00:00", "dateUpdated": "2024-08-03T14:31:46.241Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49122
Vulnerability from cvelistv5
Published
2024-01-09 09:59
Modified
2024-08-02 21:46
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens | Solid Edge SE2023 |
Version: All versions < V223.0 Update 10 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:46:28.906Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0 Update 10" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122: Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-09T09:59:53.759Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-49122", "datePublished": "2024-01-09T09:59:53.759Z", "dateReserved": "2023-11-22T14:43:13.524Z", "dateUpdated": "2024-08-02T21:46:28.906Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49124
Vulnerability from cvelistv5
Published
2024-01-09 09:59
Modified
2024-08-02 21:46
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens | Solid Edge SE2023 |
Version: All versions < V223.0 Update 10 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:46:29.194Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0 Update 10" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-09T09:59:56.361Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-49124", "datePublished": "2024-01-09T09:59:56.361Z", "dateReserved": "2023-11-22T14:43:13.524Z", "dateUpdated": "2024-08-02T21:46:29.194Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-46346
Vulnerability from cvelistv5
Published
2022-12-13 00:00
Modified
2024-08-03 14:31
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19071)
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Parasolid V33.1 |
Version: All versions < V33.1.264 |
||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:31:45.864Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Parasolid V33.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V33.1.264" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V34.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V34.0.252" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V34.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V34.1.242" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V35.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V35.0.170" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19071)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787: Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:11.475Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-46346", "datePublished": "2022-12-13T00:00:00", "dateReserved": "2022-11-30T00:00:00", "dateUpdated": "2024-08-03T14:31:45.864Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-24549
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2022 |
Version: All versions < V222.0MP12 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:03:18.596Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121: Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:15.989Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-24549", "datePublished": "2023-02-14T10:36:25.778Z", "dateReserved": "2023-01-26T14:06:35.398Z", "dateUpdated": "2024-08-02T11:03:18.596Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49128
Vulnerability from cvelistv5
Published
2024-01-09 10:00
Modified
2024-08-02 21:46
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens | Solid Edge SE2023 |
Version: All versions < V223.0 Update 10 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:46:29.230Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0 Update 10" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787: Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-09T10:00:00.630Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-49128", "datePublished": "2024-01-09T10:00:00.630Z", "dateReserved": "2023-11-22T14:50:33.103Z", "dateUpdated": "2024-08-02T21:46:29.230Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-24562
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 11:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2022 |
Version: All versions < V222.0MP12 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:03:18.854Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2022", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V222.0MP12" } ] }, { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0Update2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-824", "description": "CWE-824: Access of Uninitialized Pointer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-14T09:31:29.675Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-24562", "datePublished": "2023-02-14T10:36:40.716Z", "dateReserved": "2023-01-26T14:06:35.401Z", "dateUpdated": "2024-08-02T11:03:18.854Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }