Search criteria
15 vulnerabilities found for solid_edge_se2025 by siemens
FKIE_CVE-2025-40812
Vulnerability from fkie_nvd - Published: 2025-10-14 10:15 - Updated: 2025-10-16 13:50
Severity ?
Summary
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
References
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-541582.html | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | solid_edge_se2024 | - | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2025 | - | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:-:*:*:*:*:*:*:*",
"matchCriteriaId": "893736B3-0140-4775-8700-CB9D7719DDE5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:-:*:*:*:*:*:*",
"matchCriteriaId": "A0119E8F-1FAF-4A3B-B6E9-20F78360FC82",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0001:*:*:*:*:*:*",
"matchCriteriaId": "829C4AEB-7C8D-408B-A79C-8684753F45E1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00010:*:*:*:*:*:*",
"matchCriteriaId": "8E262AB3-8C47-430A-9D42-89317CB630C5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00011:*:*:*:*:*:*",
"matchCriteriaId": "94758C94-F427-480E-A9F1-109D8660C4E0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00012:*:*:*:*:*:*",
"matchCriteriaId": "D084D11C-08FB-4EEE-A5E3-D93C10103D2A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00013:*:*:*:*:*:*",
"matchCriteriaId": "F8A834C5-1E45-4087-A3A4-C059A2C9960C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0002:*:*:*:*:*:*",
"matchCriteriaId": "1E8FB23E-280D-46FD-BD44-5D4552639E00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0003:*:*:*:*:*:*",
"matchCriteriaId": "CA2417A0-DD31-46FC-8D5A-9128B86C9352",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0004:*:*:*:*:*:*",
"matchCriteriaId": "3CA9C494-767C-4CFA-AB07-106298B7B2C4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0005:*:*:*:*:*:*",
"matchCriteriaId": "C3738D73-82A5-41E4-8083-34611A6301BE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0006:*:*:*:*:*:*",
"matchCriteriaId": "5634352F-0DD1-4731-9E43-61D0A9A40D1B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0007:*:*:*:*:*:*",
"matchCriteriaId": "32E3D549-54F0-4909-830D-BDE8CDAD5AF7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0008:*:*:*:*:*:*",
"matchCriteriaId": "1137D7B3-17AD-4997-AC19-4308AA5C9438",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0009:*:*:*:*:*:*",
"matchCriteriaId": "E5488DEB-3165-4F88-8C63-7B9BC212DEFF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9EBC379B-A9D5-4587-87A1-59D2D8EF2267",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:-:*:*:*:*:*:*",
"matchCriteriaId": "3D717792-2F86-43CD-973B-249171094C6C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0001:*:*:*:*:*:*",
"matchCriteriaId": "2C6F3C20-8AB5-4A6A-8524-C7CBC4A4D973",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0002:*:*:*:*:*:*",
"matchCriteriaId": "03CCA3A8-F8D6-4C80-BC03-15B865CE46B7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0003:*:*:*:*:*:*",
"matchCriteriaId": "B51556E8-9A3B-4755-BC2C-8FACABC01A7B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0004:*:*:*:*:*:*",
"matchCriteriaId": "737A4807-387D-4099-880D-2CCEE7B77B44",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0005:*:*:*:*:*:*",
"matchCriteriaId": "9267F09C-5EFD-443F-ABE0-974C1D034464",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2024 (All versions \u003c V224.0 Update 14), Solid Edge SE2025 (All versions \u003c V225.0 Update 6). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process."
}
],
"id": "CVE-2025-40812",
"lastModified": "2025-10-16T13:50:53.083",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "productcert@siemens.com",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
},
"published": "2025-10-14T10:15:40.090",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-541582.html"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-125"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2025-40810
Vulnerability from fkie_nvd - Published: 2025-10-14 10:15 - Updated: 2025-10-16 13:56
Severity ?
Summary
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
References
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-541582.html | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | solid_edge_se2024 | - | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2025 | - | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:-:*:*:*:*:*:*:*",
"matchCriteriaId": "893736B3-0140-4775-8700-CB9D7719DDE5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:-:*:*:*:*:*:*",
"matchCriteriaId": "A0119E8F-1FAF-4A3B-B6E9-20F78360FC82",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0001:*:*:*:*:*:*",
"matchCriteriaId": "829C4AEB-7C8D-408B-A79C-8684753F45E1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00010:*:*:*:*:*:*",
"matchCriteriaId": "8E262AB3-8C47-430A-9D42-89317CB630C5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00011:*:*:*:*:*:*",
"matchCriteriaId": "94758C94-F427-480E-A9F1-109D8660C4E0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00012:*:*:*:*:*:*",
"matchCriteriaId": "D084D11C-08FB-4EEE-A5E3-D93C10103D2A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00013:*:*:*:*:*:*",
"matchCriteriaId": "F8A834C5-1E45-4087-A3A4-C059A2C9960C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0002:*:*:*:*:*:*",
"matchCriteriaId": "1E8FB23E-280D-46FD-BD44-5D4552639E00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0003:*:*:*:*:*:*",
"matchCriteriaId": "CA2417A0-DD31-46FC-8D5A-9128B86C9352",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0004:*:*:*:*:*:*",
"matchCriteriaId": "3CA9C494-767C-4CFA-AB07-106298B7B2C4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0005:*:*:*:*:*:*",
"matchCriteriaId": "C3738D73-82A5-41E4-8083-34611A6301BE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0006:*:*:*:*:*:*",
"matchCriteriaId": "5634352F-0DD1-4731-9E43-61D0A9A40D1B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0007:*:*:*:*:*:*",
"matchCriteriaId": "32E3D549-54F0-4909-830D-BDE8CDAD5AF7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0008:*:*:*:*:*:*",
"matchCriteriaId": "1137D7B3-17AD-4997-AC19-4308AA5C9438",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0009:*:*:*:*:*:*",
"matchCriteriaId": "E5488DEB-3165-4F88-8C63-7B9BC212DEFF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9EBC379B-A9D5-4587-87A1-59D2D8EF2267",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:-:*:*:*:*:*:*",
"matchCriteriaId": "3D717792-2F86-43CD-973B-249171094C6C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0001:*:*:*:*:*:*",
"matchCriteriaId": "2C6F3C20-8AB5-4A6A-8524-C7CBC4A4D973",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0002:*:*:*:*:*:*",
"matchCriteriaId": "03CCA3A8-F8D6-4C80-BC03-15B865CE46B7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0003:*:*:*:*:*:*",
"matchCriteriaId": "B51556E8-9A3B-4755-BC2C-8FACABC01A7B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0004:*:*:*:*:*:*",
"matchCriteriaId": "737A4807-387D-4099-880D-2CCEE7B77B44",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0005:*:*:*:*:*:*",
"matchCriteriaId": "9267F09C-5EFD-443F-ABE0-974C1D034464",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2024 (All versions \u003c V224.0 Update 14), Solid Edge SE2025 (All versions \u003c V225.0 Update 6). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process."
}
],
"id": "CVE-2025-40810",
"lastModified": "2025-10-16T13:56:28.707",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "productcert@siemens.com",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
},
"published": "2025-10-14T10:15:39.760",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-541582.html"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2025-40809
Vulnerability from fkie_nvd - Published: 2025-10-14 10:15 - Updated: 2025-10-16 14:03
Severity ?
Summary
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
References
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-541582.html | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | solid_edge_se2024 | - | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2025 | - | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:-:*:*:*:*:*:*:*",
"matchCriteriaId": "893736B3-0140-4775-8700-CB9D7719DDE5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:-:*:*:*:*:*:*",
"matchCriteriaId": "A0119E8F-1FAF-4A3B-B6E9-20F78360FC82",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0001:*:*:*:*:*:*",
"matchCriteriaId": "829C4AEB-7C8D-408B-A79C-8684753F45E1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00010:*:*:*:*:*:*",
"matchCriteriaId": "8E262AB3-8C47-430A-9D42-89317CB630C5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00011:*:*:*:*:*:*",
"matchCriteriaId": "94758C94-F427-480E-A9F1-109D8660C4E0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00012:*:*:*:*:*:*",
"matchCriteriaId": "D084D11C-08FB-4EEE-A5E3-D93C10103D2A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00013:*:*:*:*:*:*",
"matchCriteriaId": "F8A834C5-1E45-4087-A3A4-C059A2C9960C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0002:*:*:*:*:*:*",
"matchCriteriaId": "1E8FB23E-280D-46FD-BD44-5D4552639E00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0003:*:*:*:*:*:*",
"matchCriteriaId": "CA2417A0-DD31-46FC-8D5A-9128B86C9352",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0004:*:*:*:*:*:*",
"matchCriteriaId": "3CA9C494-767C-4CFA-AB07-106298B7B2C4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0005:*:*:*:*:*:*",
"matchCriteriaId": "C3738D73-82A5-41E4-8083-34611A6301BE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0006:*:*:*:*:*:*",
"matchCriteriaId": "5634352F-0DD1-4731-9E43-61D0A9A40D1B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0007:*:*:*:*:*:*",
"matchCriteriaId": "32E3D549-54F0-4909-830D-BDE8CDAD5AF7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0008:*:*:*:*:*:*",
"matchCriteriaId": "1137D7B3-17AD-4997-AC19-4308AA5C9438",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0009:*:*:*:*:*:*",
"matchCriteriaId": "E5488DEB-3165-4F88-8C63-7B9BC212DEFF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9EBC379B-A9D5-4587-87A1-59D2D8EF2267",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:-:*:*:*:*:*:*",
"matchCriteriaId": "3D717792-2F86-43CD-973B-249171094C6C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0001:*:*:*:*:*:*",
"matchCriteriaId": "2C6F3C20-8AB5-4A6A-8524-C7CBC4A4D973",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0002:*:*:*:*:*:*",
"matchCriteriaId": "03CCA3A8-F8D6-4C80-BC03-15B865CE46B7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0003:*:*:*:*:*:*",
"matchCriteriaId": "B51556E8-9A3B-4755-BC2C-8FACABC01A7B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0004:*:*:*:*:*:*",
"matchCriteriaId": "737A4807-387D-4099-880D-2CCEE7B77B44",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0005:*:*:*:*:*:*",
"matchCriteriaId": "9267F09C-5EFD-443F-ABE0-974C1D034464",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2024 (All versions \u003c V224.0 Update 14), Solid Edge SE2025 (All versions \u003c V225.0 Update 6). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process."
}
],
"id": "CVE-2025-40809",
"lastModified": "2025-10-16T14:03:17.823",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "productcert@siemens.com",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
},
"published": "2025-10-14T10:15:39.580",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-541582.html"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2025-40811
Vulnerability from fkie_nvd - Published: 2025-10-14 10:15 - Updated: 2025-10-16 13:52
Severity ?
Summary
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
References
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-541582.html | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | solid_edge_se2024 | - | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2025 | - | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:-:*:*:*:*:*:*:*",
"matchCriteriaId": "893736B3-0140-4775-8700-CB9D7719DDE5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:-:*:*:*:*:*:*",
"matchCriteriaId": "A0119E8F-1FAF-4A3B-B6E9-20F78360FC82",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0001:*:*:*:*:*:*",
"matchCriteriaId": "829C4AEB-7C8D-408B-A79C-8684753F45E1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00010:*:*:*:*:*:*",
"matchCriteriaId": "8E262AB3-8C47-430A-9D42-89317CB630C5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00011:*:*:*:*:*:*",
"matchCriteriaId": "94758C94-F427-480E-A9F1-109D8660C4E0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00012:*:*:*:*:*:*",
"matchCriteriaId": "D084D11C-08FB-4EEE-A5E3-D93C10103D2A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00013:*:*:*:*:*:*",
"matchCriteriaId": "F8A834C5-1E45-4087-A3A4-C059A2C9960C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0002:*:*:*:*:*:*",
"matchCriteriaId": "1E8FB23E-280D-46FD-BD44-5D4552639E00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0003:*:*:*:*:*:*",
"matchCriteriaId": "CA2417A0-DD31-46FC-8D5A-9128B86C9352",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0004:*:*:*:*:*:*",
"matchCriteriaId": "3CA9C494-767C-4CFA-AB07-106298B7B2C4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0005:*:*:*:*:*:*",
"matchCriteriaId": "C3738D73-82A5-41E4-8083-34611A6301BE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0006:*:*:*:*:*:*",
"matchCriteriaId": "5634352F-0DD1-4731-9E43-61D0A9A40D1B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0007:*:*:*:*:*:*",
"matchCriteriaId": "32E3D549-54F0-4909-830D-BDE8CDAD5AF7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0008:*:*:*:*:*:*",
"matchCriteriaId": "1137D7B3-17AD-4997-AC19-4308AA5C9438",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0009:*:*:*:*:*:*",
"matchCriteriaId": "E5488DEB-3165-4F88-8C63-7B9BC212DEFF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9EBC379B-A9D5-4587-87A1-59D2D8EF2267",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:-:*:*:*:*:*:*",
"matchCriteriaId": "3D717792-2F86-43CD-973B-249171094C6C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0001:*:*:*:*:*:*",
"matchCriteriaId": "2C6F3C20-8AB5-4A6A-8524-C7CBC4A4D973",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0002:*:*:*:*:*:*",
"matchCriteriaId": "03CCA3A8-F8D6-4C80-BC03-15B865CE46B7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0003:*:*:*:*:*:*",
"matchCriteriaId": "B51556E8-9A3B-4755-BC2C-8FACABC01A7B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0004:*:*:*:*:*:*",
"matchCriteriaId": "737A4807-387D-4099-880D-2CCEE7B77B44",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0005:*:*:*:*:*:*",
"matchCriteriaId": "9267F09C-5EFD-443F-ABE0-974C1D034464",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2024 (All versions \u003c V224.0 Update 14), Solid Edge SE2025 (All versions \u003c V225.0 Update 6). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process."
}
],
"id": "CVE-2025-40811",
"lastModified": "2025-10-16T13:52:24.733",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "productcert@siemens.com",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
},
"published": "2025-10-14T10:15:39.923",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-541582.html"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-125"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-54091
Vulnerability from fkie_nvd - Published: 2024-12-10 14:30 - Updated: 2025-10-29 14:21
Severity ?
Summary
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 12), Solid Edge SE2025 (All versions < V225.0 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer while parsing X_T data or a specially crafted file in X_T format.
This could allow an attacker to execute code in the context of the current process.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | parasolid | * | |
| siemens | parasolid | * | |
| siemens | solid_edge_se2024 | - | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2024 | 224.0 | |
| siemens | solid_edge_se2025 | - | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 | |
| siemens | solid_edge_se2025 | 225.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D20F4CD4-F876-4743-A15B-99B0085AF013",
"versionEndExcluding": "36.1.225",
"versionStartIncluding": "36.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CD7F5D01-5253-4C5A-A399-6E4D2EE1CD1D",
"versionEndExcluding": "37.0.173",
"versionStartIncluding": "37.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:-:*:*:*:*:*:*:*",
"matchCriteriaId": "893736B3-0140-4775-8700-CB9D7719DDE5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:-:*:*:*:*:*:*",
"matchCriteriaId": "A0119E8F-1FAF-4A3B-B6E9-20F78360FC82",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0001:*:*:*:*:*:*",
"matchCriteriaId": "829C4AEB-7C8D-408B-A79C-8684753F45E1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00010:*:*:*:*:*:*",
"matchCriteriaId": "8E262AB3-8C47-430A-9D42-89317CB630C5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00011:*:*:*:*:*:*",
"matchCriteriaId": "94758C94-F427-480E-A9F1-109D8660C4E0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0002:*:*:*:*:*:*",
"matchCriteriaId": "1E8FB23E-280D-46FD-BD44-5D4552639E00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0003:*:*:*:*:*:*",
"matchCriteriaId": "CA2417A0-DD31-46FC-8D5A-9128B86C9352",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0004:*:*:*:*:*:*",
"matchCriteriaId": "3CA9C494-767C-4CFA-AB07-106298B7B2C4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0005:*:*:*:*:*:*",
"matchCriteriaId": "C3738D73-82A5-41E4-8083-34611A6301BE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0006:*:*:*:*:*:*",
"matchCriteriaId": "5634352F-0DD1-4731-9E43-61D0A9A40D1B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0007:*:*:*:*:*:*",
"matchCriteriaId": "32E3D549-54F0-4909-830D-BDE8CDAD5AF7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0008:*:*:*:*:*:*",
"matchCriteriaId": "1137D7B3-17AD-4997-AC19-4308AA5C9438",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0009:*:*:*:*:*:*",
"matchCriteriaId": "E5488DEB-3165-4F88-8C63-7B9BC212DEFF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9EBC379B-A9D5-4587-87A1-59D2D8EF2267",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:-:*:*:*:*:*:*",
"matchCriteriaId": "3D717792-2F86-43CD-973B-249171094C6C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0001:*:*:*:*:*:*",
"matchCriteriaId": "2C6F3C20-8AB5-4A6A-8524-C7CBC4A4D973",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0002:*:*:*:*:*:*",
"matchCriteriaId": "03CCA3A8-F8D6-4C80-BC03-15B865CE46B7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0003:*:*:*:*:*:*",
"matchCriteriaId": "B51556E8-9A3B-4755-BC2C-8FACABC01A7B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2024 (All versions \u003c V224.0 Update 12), Solid Edge SE2025 (All versions \u003c V225.0 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer while parsing X_T data or a specially crafted file in X_T format.\r\nThis could allow an attacker to execute code in the context of the current process."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Parasolid V36.1 (todas las versiones anteriores a V36.1.225), Parasolid V37.0 (todas las versiones anteriores a V37.0.173) y Parasolid V37.1 (todas las versiones anteriores a V37.1.109). Las aplicaciones afectadas contienen una vulnerabilidad de escritura fuera de los l\u00edmites al analizar archivos PAR especialmente manipulados. Esto podr\u00eda permitir que un atacante ejecute c\u00f3digo en el contexto del proceso actual."
}
],
"id": "CVE-2024-54091",
"lastModified": "2025-10-29T14:21:57.357",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "productcert@siemens.com",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
},
"published": "2024-12-10T14:30:47.193",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-672923.html"
},
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-979056.html"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
}
CVE-2025-40812 (GCVE-0-2025-40812)
Vulnerability from cvelistv5 – Published: 2025-10-14 09:15 – Updated: 2025-10-14 19:04
VLAI?
Summary
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Solid Edge SE2024 |
Affected:
0 , < V224.0 Update 14
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40812",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-14T19:04:30.294501Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T19:04:38.253Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2024",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V224.0 Update 14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2025",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V225.0 Update 6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2024 (All versions \u003c V224.0 Update 14), Solid Edge SE2025 (All versions \u003c V225.0 Update 6). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T09:15:32.119Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-541582.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40812",
"datePublished": "2025-10-14T09:15:32.119Z",
"dateReserved": "2025-04-16T08:50:26.974Z",
"dateUpdated": "2025-10-14T19:04:38.253Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-40811 (GCVE-0-2025-40811)
Vulnerability from cvelistv5 – Published: 2025-10-14 09:15 – Updated: 2025-10-14 19:04
VLAI?
Summary
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Solid Edge SE2024 |
Affected:
0 , < V224.0 Update 14
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40811",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-14T19:04:09.737983Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T19:04:17.527Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2024",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V224.0 Update 14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2025",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V225.0 Update 6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2024 (All versions \u003c V224.0 Update 14), Solid Edge SE2025 (All versions \u003c V225.0 Update 6). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T09:15:29.918Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-541582.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40811",
"datePublished": "2025-10-14T09:15:29.918Z",
"dateReserved": "2025-04-16T08:50:26.974Z",
"dateUpdated": "2025-10-14T19:04:17.527Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-40810 (GCVE-0-2025-40810)
Vulnerability from cvelistv5 – Published: 2025-10-14 09:15 – Updated: 2025-10-14 19:03
VLAI?
Summary
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Solid Edge SE2024 |
Affected:
0 , < V224.0 Update 14
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40810",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-14T19:03:47.230515Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T19:03:57.041Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2024",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V224.0 Update 14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2025",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V225.0 Update 6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2024 (All versions \u003c V224.0 Update 14), Solid Edge SE2025 (All versions \u003c V225.0 Update 6). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T09:15:28.668Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-541582.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40810",
"datePublished": "2025-10-14T09:15:28.668Z",
"dateReserved": "2025-04-16T08:50:26.974Z",
"dateUpdated": "2025-10-14T19:03:57.041Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-40809 (GCVE-0-2025-40809)
Vulnerability from cvelistv5 – Published: 2025-10-14 09:15 – Updated: 2025-10-14 19:03
VLAI?
Summary
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Solid Edge SE2024 |
Affected:
0 , < V224.0 Update 14
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40809",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-14T19:03:27.180888Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T19:03:33.965Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2024",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V224.0 Update 14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2025",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V225.0 Update 6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2024 (All versions \u003c V224.0 Update 14), Solid Edge SE2025 (All versions \u003c V225.0 Update 6). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T09:15:27.478Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-541582.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40809",
"datePublished": "2025-10-14T09:15:27.478Z",
"dateReserved": "2025-04-16T08:50:26.974Z",
"dateUpdated": "2025-10-14T19:03:33.965Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-54091 (GCVE-0-2024-54091)
Vulnerability from cvelistv5 – Published: 2024-12-10 13:54 – Updated: 2025-04-08 08:22
VLAI?
Summary
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 12), Solid Edge SE2025 (All versions < V225.0 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer while parsing X_T data or a specially crafted file in X_T format.
This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Solid Edge SE2024 |
Affected:
0 , < V224.0 Update 12
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-54091",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-10T15:15:24.096235Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T17:17:59.464Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2024",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V224.0 Update 12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2025",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V225.0 Update 3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2024 (All versions \u003c V224.0 Update 12), Solid Edge SE2025 (All versions \u003c V225.0 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer while parsing X_T data or a specially crafted file in X_T format.\r\nThis could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-08T08:22:23.402Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-979056.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-672923.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-54091",
"datePublished": "2024-12-10T13:54:17.315Z",
"dateReserved": "2024-11-28T12:05:26.694Z",
"dateUpdated": "2025-04-08T08:22:23.402Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-40812 (GCVE-0-2025-40812)
Vulnerability from nvd – Published: 2025-10-14 09:15 – Updated: 2025-10-14 19:04
VLAI?
Summary
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Solid Edge SE2024 |
Affected:
0 , < V224.0 Update 14
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40812",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-14T19:04:30.294501Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T19:04:38.253Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2024",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V224.0 Update 14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2025",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V225.0 Update 6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2024 (All versions \u003c V224.0 Update 14), Solid Edge SE2025 (All versions \u003c V225.0 Update 6). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T09:15:32.119Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-541582.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40812",
"datePublished": "2025-10-14T09:15:32.119Z",
"dateReserved": "2025-04-16T08:50:26.974Z",
"dateUpdated": "2025-10-14T19:04:38.253Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-40811 (GCVE-0-2025-40811)
Vulnerability from nvd – Published: 2025-10-14 09:15 – Updated: 2025-10-14 19:04
VLAI?
Summary
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Solid Edge SE2024 |
Affected:
0 , < V224.0 Update 14
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40811",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-14T19:04:09.737983Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T19:04:17.527Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2024",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V224.0 Update 14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2025",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V225.0 Update 6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2024 (All versions \u003c V224.0 Update 14), Solid Edge SE2025 (All versions \u003c V225.0 Update 6). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T09:15:29.918Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-541582.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40811",
"datePublished": "2025-10-14T09:15:29.918Z",
"dateReserved": "2025-04-16T08:50:26.974Z",
"dateUpdated": "2025-10-14T19:04:17.527Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-40810 (GCVE-0-2025-40810)
Vulnerability from nvd – Published: 2025-10-14 09:15 – Updated: 2025-10-14 19:03
VLAI?
Summary
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Solid Edge SE2024 |
Affected:
0 , < V224.0 Update 14
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40810",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-14T19:03:47.230515Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T19:03:57.041Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2024",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V224.0 Update 14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2025",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V225.0 Update 6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2024 (All versions \u003c V224.0 Update 14), Solid Edge SE2025 (All versions \u003c V225.0 Update 6). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T09:15:28.668Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-541582.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40810",
"datePublished": "2025-10-14T09:15:28.668Z",
"dateReserved": "2025-04-16T08:50:26.974Z",
"dateUpdated": "2025-10-14T19:03:57.041Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-40809 (GCVE-0-2025-40809)
Vulnerability from nvd – Published: 2025-10-14 09:15 – Updated: 2025-10-14 19:03
VLAI?
Summary
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Solid Edge SE2024 |
Affected:
0 , < V224.0 Update 14
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40809",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-14T19:03:27.180888Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T19:03:33.965Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2024",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V224.0 Update 14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2025",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V225.0 Update 6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2024 (All versions \u003c V224.0 Update 14), Solid Edge SE2025 (All versions \u003c V225.0 Update 6). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T09:15:27.478Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-541582.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40809",
"datePublished": "2025-10-14T09:15:27.478Z",
"dateReserved": "2025-04-16T08:50:26.974Z",
"dateUpdated": "2025-10-14T19:03:33.965Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-54091 (GCVE-0-2024-54091)
Vulnerability from nvd – Published: 2024-12-10 13:54 – Updated: 2025-04-08 08:22
VLAI?
Summary
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 12), Solid Edge SE2025 (All versions < V225.0 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer while parsing X_T data or a specially crafted file in X_T format.
This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Solid Edge SE2024 |
Affected:
0 , < V224.0 Update 12
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-54091",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-10T15:15:24.096235Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T17:17:59.464Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2024",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V224.0 Update 12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2025",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V225.0 Update 3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2024 (All versions \u003c V224.0 Update 12), Solid Edge SE2025 (All versions \u003c V225.0 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer while parsing X_T data or a specially crafted file in X_T format.\r\nThis could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-08T08:22:23.402Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-979056.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-672923.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-54091",
"datePublished": "2024-12-10T13:54:17.315Z",
"dateReserved": "2024-11-28T12:05:26.694Z",
"dateUpdated": "2025-04-08T08:22:23.402Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}