Search criteria

6 vulnerabilities found for spacelogic_as-b_firmware by schneider-electric

FKIE_CVE-2024-5558

Vulnerability from fkie_nvd - Published: 2024-06-12 17:15 - Updated: 2024-11-21 09:47

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:spacelogic_as-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5BD47138-7C8F-4D8B-A669-74395596363D",
              "versionEndExcluding": "6.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:spacelogic_as-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A50B62A0-A6FB-4AB4-94A0-D054C5ADB015",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:spacelogic_as-p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA1ABCFA-8D7D-4288-AA9F-FF1B177DBB4E",
              "versionEndExcluding": "6.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:spacelogic_as-p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E516910C-FC39-46FA-82A5-0BF3546FDF33",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could\ncause escalation of privileges when an attacker abuses a limited admin account."
    },
    {
      "lang": "es",
      "value": "CWE-367: Existe una vulnerabilidad de condici\u00f3n de ejecuci\u00f3n de tiempo de verificaci\u00f3n y tiempo de uso (TOCTOU) que podr\u00eda provocar una escalada de privilegios cuando un atacante abusa de una cuenta de administrador limitada."
    }
  ],
  "id": "CVE-2024-5558",
  "lastModified": "2024-11-21T09:47:55.700",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.4,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.5,
        "impactScore": 5.9,
        "source": "cybersecurity@se.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.4,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.5,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-06-12T17:15:52.160",
  "references": [
    {
      "source": "cybersecurity@se.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-367"
        }
      ],
      "source": "cybersecurity@se.com",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2024-5557

Vulnerability from fkie_nvd - Published: 2024-06-12 17:15 - Updated: 2024-11-21 09:47

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:spacelogic_as-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5BD47138-7C8F-4D8B-A669-74395596363D",
              "versionEndExcluding": "6.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:spacelogic_as-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A50B62A0-A6FB-4AB4-94A0-D054C5ADB015",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:spacelogic_as-p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA1ABCFA-8D7D-4288-AA9F-FF1B177DBB4E",
              "versionEndExcluding": "6.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:spacelogic_as-p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E516910C-FC39-46FA-82A5-0BF3546FDF33",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause\nexposure of SNMP credentials when an attacker has access to the controller logs."
    },
    {
      "lang": "es",
      "value": "CWE-532: Existe una vulnerabilidad de inserci\u00f3n de informaci\u00f3n confidencial en el archivo de registro que podr\u00eda causar la exposici\u00f3n de las credenciales SNMP cuando un atacante tiene acceso a los registros del controlador."
    }
  ],
  "id": "CVE-2024-5557",
  "lastModified": "2024-11-21T09:47:55.560",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 3.6,
        "source": "cybersecurity@se.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-06-12T17:15:51.943",
  "references": [
    {
      "source": "cybersecurity@se.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "cybersecurity@se.com",
      "type": "Primary"
    }
  ]
}

CVE-2024-5557 (GCVE-0-2024-5557)

Vulnerability from cvelistv5 – Published: 2024-06-12 16:28 – Updated: 2024-08-01 21:18
VLAI?
Summary
CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause exposure of SNMP credentials when an attacker has access to the controller logs.
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:spacelogic_as-b:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "spacelogic_as-b",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "5.0.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:spacelogic_as-p:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "spacelogic_as-p",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "5.0.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5557",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T18:09:17.413313Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-12T18:09:28.568Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:18:06.830Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SpaceLogic AS-P",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V5.0.3 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SpaceLogic AS-B",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V5.0.3 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause\nexposure of SNMP credentials when an attacker has access to the controller logs."
            }
          ],
          "value": "CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause\nexposure of SNMP credentials when an attacker has access to the controller logs."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-13T19:01:56.888Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-5557",
    "datePublished": "2024-06-12T16:28:56.844Z",
    "dateReserved": "2024-05-31T06:58:40.277Z",
    "dateUpdated": "2024-08-01T21:18:06.830Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-5558 (GCVE-0-2024-5558)

Vulnerability from cvelistv5 – Published: 2024-06-12 16:26 – Updated: 2024-08-01 21:18
VLAI?
Summary
CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could cause escalation of privileges when an attacker abuses a limited admin account.
CWE
  • CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:spacelogic_as-b:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "spacelogic_as-b",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "5.0.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:spacelogic_as-p:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "spacelogic_as-p",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "5.0.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5558",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T18:07:10.554620Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-23T16:20:36.411Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:18:06.335Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SpaceLogic AS-P",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V5.0.3 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SpaceLogic AS-B",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V5.0.3 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nCWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could\ncause escalation of privileges when an attacker abuses a limited admin account.\n\n"
            }
          ],
          "value": "CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could\ncause escalation of privileges when an attacker abuses a limited admin account."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-367",
              "description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-12T16:26:26.294Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-5558",
    "datePublished": "2024-06-12T16:26:26.294Z",
    "dateReserved": "2024-05-31T06:58:47.453Z",
    "dateUpdated": "2024-08-01T21:18:06.335Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-5557 (GCVE-0-2024-5557)

Vulnerability from nvd – Published: 2024-06-12 16:28 – Updated: 2024-08-01 21:18
VLAI?
Summary
CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause exposure of SNMP credentials when an attacker has access to the controller logs.
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:spacelogic_as-b:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "spacelogic_as-b",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "5.0.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:spacelogic_as-p:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "spacelogic_as-p",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "5.0.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5557",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T18:09:17.413313Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-12T18:09:28.568Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:18:06.830Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SpaceLogic AS-P",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V5.0.3 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SpaceLogic AS-B",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V5.0.3 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause\nexposure of SNMP credentials when an attacker has access to the controller logs."
            }
          ],
          "value": "CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause\nexposure of SNMP credentials when an attacker has access to the controller logs."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-13T19:01:56.888Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-5557",
    "datePublished": "2024-06-12T16:28:56.844Z",
    "dateReserved": "2024-05-31T06:58:40.277Z",
    "dateUpdated": "2024-08-01T21:18:06.830Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-5558 (GCVE-0-2024-5558)

Vulnerability from nvd – Published: 2024-06-12 16:26 – Updated: 2024-08-01 21:18
VLAI?
Summary
CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could cause escalation of privileges when an attacker abuses a limited admin account.
CWE
  • CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:spacelogic_as-b:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "spacelogic_as-b",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "5.0.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:spacelogic_as-p:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "spacelogic_as-p",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "5.0.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5558",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T18:07:10.554620Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-23T16:20:36.411Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:18:06.335Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SpaceLogic AS-P",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V5.0.3 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SpaceLogic AS-B",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V5.0.3 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nCWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could\ncause escalation of privileges when an attacker abuses a limited admin account.\n\n"
            }
          ],
          "value": "CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could\ncause escalation of privileges when an attacker abuses a limited admin account."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-367",
              "description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-12T16:26:26.294Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-5558",
    "datePublished": "2024-06-12T16:26:26.294Z",
    "dateReserved": "2024-05-31T06:58:47.453Z",
    "dateUpdated": "2024-08-01T21:18:06.335Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}