Search criteria
3 vulnerabilities found for telemetry_dashboard by dell
FKIE_CVE-2024-28963
Vulnerability from fkie_nvd - Published: 2024-04-24 08:15 - Updated: 2025-02-04 17:09
Severity ?
6.2 (Medium) - CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Summary
Telemetry Dashboard v1.0.0.7 for Dell ThinOS 2402 contains a sensitive information disclosure vulnerability. An unauthenticated user with local access to the device could exploit this vulnerability to read sensitive proxy settings information.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | telemetry_dashboard | 1.0.0.7 | |
| dell | thinos | 2402 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:telemetry_dashboard:1.0.0.7:*:*:*:*:*:*:*",
"matchCriteriaId": "59738A58-246A-4D1C-9519-897D8579731E",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dell:thinos:2402:*:*:*:*:*:*:*",
"matchCriteriaId": "ECA47B8D-21C0-4AF5-B975-DE6DA9D73FC1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Telemetry Dashboard v1.0.0.7 for Dell ThinOS 2402 contains a sensitive information disclosure vulnerability. An unauthenticated user with local access to the device could exploit this vulnerability to read sensitive proxy settings information."
},
{
"lang": "es",
"value": "Telemetry Dashboard v1.0.0.7 para Dell ThinOS 2402 contiene una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n confidencial. Un usuario no autenticado con acceso local al dispositivo podr\u00eda aprovechar esta vulnerabilidad para leer informaci\u00f3n confidencial de configuraci\u00f3n del proxy."
}
],
"id": "CVE-2024-28963",
"lastModified": "2025-02-04T17:09:31.697",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.5,
"impactScore": 3.6,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2024-04-24T08:15:37.400",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000224317/dsa-2024-170"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000224317/dsa-2024-170"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-200"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2024-28963 (GCVE-0-2024-28963)
Vulnerability from cvelistv5 – Published: 2024-04-24 07:54 – Updated: 2024-08-02 01:03
VLAI?
Summary
Telemetry Dashboard v1.0.0.7 for Dell ThinOS 2402 contains a sensitive information disclosure vulnerability. An unauthenticated user with local access to the device could exploit this vulnerability to read sensitive proxy settings information.
Severity ?
6.2 (Medium)
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Wyse Proprietary OS (Modern ThinOS) |
Affected:
N/A , ≤ 1.0.0.7
(semver)
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:dell:wyse_thinos:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wyse_thinos",
"vendor": "dell",
"versions": [
{
"status": "affected",
"version": "*"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-28963",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-24T14:23:09.889104Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T18:03:16.527Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:03:51.335Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000224317/dsa-2024-170"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Wyse Proprietary OS (Modern ThinOS)",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "1.0.0.7",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"datePublic": "2024-04-23T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Telemetry Dashboard v1.0.0.7 for Dell ThinOS 2402 contains a sensitive information disclosure vulnerability. An unauthenticated user with local access to the device could exploit this vulnerability to read sensitive proxy settings information."
}
],
"value": "Telemetry Dashboard v1.0.0.7 for Dell ThinOS 2402 contains a sensitive information disclosure vulnerability. An unauthenticated user with local access to the device could exploit this vulnerability to read sensitive proxy settings information."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-24T07:54:11.227Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000224317/dsa-2024-170"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-28963",
"datePublished": "2024-04-24T07:54:11.227Z",
"dateReserved": "2024-03-13T15:42:12.960Z",
"dateUpdated": "2024-08-02T01:03:51.335Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-28963 (GCVE-0-2024-28963)
Vulnerability from nvd – Published: 2024-04-24 07:54 – Updated: 2024-08-02 01:03
VLAI?
Summary
Telemetry Dashboard v1.0.0.7 for Dell ThinOS 2402 contains a sensitive information disclosure vulnerability. An unauthenticated user with local access to the device could exploit this vulnerability to read sensitive proxy settings information.
Severity ?
6.2 (Medium)
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Wyse Proprietary OS (Modern ThinOS) |
Affected:
N/A , ≤ 1.0.0.7
(semver)
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:dell:wyse_thinos:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wyse_thinos",
"vendor": "dell",
"versions": [
{
"status": "affected",
"version": "*"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-28963",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-24T14:23:09.889104Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T18:03:16.527Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:03:51.335Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000224317/dsa-2024-170"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Wyse Proprietary OS (Modern ThinOS)",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "1.0.0.7",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"datePublic": "2024-04-23T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Telemetry Dashboard v1.0.0.7 for Dell ThinOS 2402 contains a sensitive information disclosure vulnerability. An unauthenticated user with local access to the device could exploit this vulnerability to read sensitive proxy settings information."
}
],
"value": "Telemetry Dashboard v1.0.0.7 for Dell ThinOS 2402 contains a sensitive information disclosure vulnerability. An unauthenticated user with local access to the device could exploit this vulnerability to read sensitive proxy settings information."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-24T07:54:11.227Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000224317/dsa-2024-170"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-28963",
"datePublished": "2024-04-24T07:54:11.227Z",
"dateReserved": "2024-03-13T15:42:12.960Z",
"dateUpdated": "2024-08-02T01:03:51.335Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}