Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
8 vulnerabilities found for unifi_network_application by ui
CVE-2024-42025 (GCVE-0-2024-42025)
Vulnerability from cvelistv5 – Published: 2024-09-13 15:47 – Updated: 2024-09-28 17:44
VLAI
Summary
A Command Injection vulnerability found in a Self-Hosted UniFi Network Servers (Linux) with UniFi Network Application (Version 8.3.32 and earlier) allows a malicious actor with unifi user shell access to escalate privileges to root on the host device.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti Inc | UniFi Network Application |
Affected:
8.4.59 , < 8.4.59
(semver)
|
|
| ubiquiti | unifi_network_application |
Affected:
0 , ≤ 8.3.32
(semver)
cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "unifi_network_application",
"vendor": "ubiquiti",
"versions": [
{
"lessThanOrEqual": "8.3.32",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-42025",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-13T16:23:49.335442Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-28T17:44:02.226Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Network Application",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "8.4.59",
"status": "affected",
"version": "8.4.59",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A Command Injection vulnerability found in a Self-Hosted UniFi Network Servers (Linux) with UniFi Network Application (Version 8.3.32 and earlier) allows a malicious actor with unifi user shell access to escalate privileges to root on the host device."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-13T15:47:19.568Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-042-042/c4f68b56-cdc4-4128-b2cb-5870209d1704"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2024-42025",
"datePublished": "2024-09-13T15:47:19.568Z",
"dateReserved": "2024-07-27T01:04:08.013Z",
"dateUpdated": "2024-09-28T17:44:02.226Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-41721 (GCVE-0-2023-41721)
Vulnerability from cvelistv5 – Published: 2023-10-25 00:24 – Updated: 2024-09-13 16:28
VLAI
Summary
Instances of UniFi Network Application that (i) are run on a UniFi Gateway Console, and (ii) are versions 7.5.176. and earlier, implement device adoption with improper access control logic, creating a risk of access to device configuration information by a malicious actor with preexisting access to the network.
Affected Products:
UDM
UDM-PRO
UDM-SE
UDR
UDW
Mitigation:
Update UniFi Network to Version 7.5.187 or later.
Severity
10 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti | UniFi Network Application |
Affected:
7.5.176 , ≤ 7.5.176
(semver)
|
|
| ubiquiti | unifi_network_application |
Affected:
0 , ≤ 7.5.176
(custom)
cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:01:35.513Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-036-036/81367bc9-2a64-4435-95dc-bbe482457615"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_network_application",
"vendor": "ubiquiti",
"versions": [
{
"lessThanOrEqual": "7.5.176",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-41721",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T20:25:31.300359Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-13T16:28:08.626Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Network Application",
"vendor": "Ubiquiti",
"versions": [
{
"lessThanOrEqual": "7.5.176",
"status": "affected",
"version": "7.5.176",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Instances of UniFi Network Application that (i) are run on a UniFi Gateway Console, and (ii) are versions 7.5.176. and earlier, implement device adoption with improper access control logic, creating a risk of access to device configuration information by a malicious actor with preexisting access to the network.\n\nAffected Products:\nUDM\nUDM-PRO\nUDM-SE\nUDR\nUDW\n \nMitigation:\nUpdate UniFi Network to Version 7.5.187 or later.\n"
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T00:24:34.072Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-036-036/81367bc9-2a64-4435-95dc-bbe482457615"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2023-41721",
"datePublished": "2023-10-25T00:24:34.072Z",
"dateReserved": "2023-08-31T01:00:11.771Z",
"dateUpdated": "2024-09-13T16:28:08.626Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-32000 (GCVE-0-2023-32000)
Vulnerability from cvelistv5 – Published: 2023-07-07 23:07 – Updated: 2024-10-21 21:11
VLAI
Summary
A Cross-Site Scripting (XSS) vulnerability found in UniFi Network (Version 7.3.83 and earlier) allows a malicious actor with Site Administrator credentials to escalate privileges by persuading an Administrator to visit a malicious web page.
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti | UniFi Network Application |
Affected:
7.3.83 , ≤ 7.3.83
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:03:28.687Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-034-034/53cfcb84-b42b-4f8f-afbf-07c0ca7cabe2"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-32000",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-21T21:06:57.989361Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-21T21:11:02.916Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Network Application",
"vendor": "Ubiquiti",
"versions": [
{
"lessThanOrEqual": "7.3.83",
"status": "affected",
"version": "7.3.83",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A Cross-Site Scripting (XSS) vulnerability found in UniFi Network (Version 7.3.83 and earlier) allows a malicious actor with Site Administrator credentials to escalate privileges by persuading an Administrator to visit a malicious web page."
}
],
"providerMetadata": {
"dateUpdated": "2023-07-07T23:07:53.212Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-034-034/53cfcb84-b42b-4f8f-afbf-07c0ca7cabe2"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2023-32000",
"datePublished": "2023-07-07T23:07:53.212Z",
"dateReserved": "2023-05-01T01:00:12.219Z",
"dateUpdated": "2024-10-21T21:11:02.916Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-28365 (GCVE-0-2023-28365)
Vulnerability from cvelistv5 – Published: 2023-06-30 23:40 – Updated: 2024-11-27 17:23
VLAI
Summary
A backup file vulnerability found in UniFi applications (Version 7.3.83 and earlier) running on Linux operating systems allows application administrators to execute malicious commands on the host device being restored.
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti Inc. | UniFi Network application |
Affected:
7.3.83 , ≤ 7.3.83
(semver)
|
|
| ubiquiti | unifi_network_application |
Affected:
0 , ≤ 7.3.83
(semver)
cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:38:25.371Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-031-031/8c85fc64-e9a8-4082-9ec4-56b14effd545"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "unifi_network_application",
"vendor": "ubiquiti",
"versions": [
{
"lessThanOrEqual": "7.3.83",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-28365",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-27T17:22:20.390330Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-27T17:23:23.036Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Network application",
"vendor": "Ubiquiti Inc.",
"versions": [
{
"lessThanOrEqual": "7.3.83",
"status": "affected",
"version": "7.3.83",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A backup file vulnerability found in UniFi applications (Version 7.3.83 and earlier) running on Linux operating systems allows application administrators to execute malicious commands on the host device being restored."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-30T23:40:13.388Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-031-031/8c85fc64-e9a8-4082-9ec4-56b14effd545"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2023-28365",
"datePublished": "2023-06-30T23:40:13.388Z",
"dateReserved": "2023-03-15T01:00:13.221Z",
"dateUpdated": "2024-11-27T17:23:23.036Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-42025 (GCVE-0-2024-42025)
Vulnerability from nvd – Published: 2024-09-13 15:47 – Updated: 2024-09-28 17:44
VLAI
Summary
A Command Injection vulnerability found in a Self-Hosted UniFi Network Servers (Linux) with UniFi Network Application (Version 8.3.32 and earlier) allows a malicious actor with unifi user shell access to escalate privileges to root on the host device.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti Inc | UniFi Network Application |
Affected:
8.4.59 , < 8.4.59
(semver)
|
|
| ubiquiti | unifi_network_application |
Affected:
0 , ≤ 8.3.32
(semver)
cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "unifi_network_application",
"vendor": "ubiquiti",
"versions": [
{
"lessThanOrEqual": "8.3.32",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-42025",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-13T16:23:49.335442Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-28T17:44:02.226Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Network Application",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "8.4.59",
"status": "affected",
"version": "8.4.59",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A Command Injection vulnerability found in a Self-Hosted UniFi Network Servers (Linux) with UniFi Network Application (Version 8.3.32 and earlier) allows a malicious actor with unifi user shell access to escalate privileges to root on the host device."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-13T15:47:19.568Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-042-042/c4f68b56-cdc4-4128-b2cb-5870209d1704"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2024-42025",
"datePublished": "2024-09-13T15:47:19.568Z",
"dateReserved": "2024-07-27T01:04:08.013Z",
"dateUpdated": "2024-09-28T17:44:02.226Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-41721 (GCVE-0-2023-41721)
Vulnerability from nvd – Published: 2023-10-25 00:24 – Updated: 2024-09-13 16:28
VLAI
Summary
Instances of UniFi Network Application that (i) are run on a UniFi Gateway Console, and (ii) are versions 7.5.176. and earlier, implement device adoption with improper access control logic, creating a risk of access to device configuration information by a malicious actor with preexisting access to the network.
Affected Products:
UDM
UDM-PRO
UDM-SE
UDR
UDW
Mitigation:
Update UniFi Network to Version 7.5.187 or later.
Severity
10 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti | UniFi Network Application |
Affected:
7.5.176 , ≤ 7.5.176
(semver)
|
|
| ubiquiti | unifi_network_application |
Affected:
0 , ≤ 7.5.176
(custom)
cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:01:35.513Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-036-036/81367bc9-2a64-4435-95dc-bbe482457615"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_network_application",
"vendor": "ubiquiti",
"versions": [
{
"lessThanOrEqual": "7.5.176",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-41721",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T20:25:31.300359Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-13T16:28:08.626Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Network Application",
"vendor": "Ubiquiti",
"versions": [
{
"lessThanOrEqual": "7.5.176",
"status": "affected",
"version": "7.5.176",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Instances of UniFi Network Application that (i) are run on a UniFi Gateway Console, and (ii) are versions 7.5.176. and earlier, implement device adoption with improper access control logic, creating a risk of access to device configuration information by a malicious actor with preexisting access to the network.\n\nAffected Products:\nUDM\nUDM-PRO\nUDM-SE\nUDR\nUDW\n \nMitigation:\nUpdate UniFi Network to Version 7.5.187 or later.\n"
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T00:24:34.072Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-036-036/81367bc9-2a64-4435-95dc-bbe482457615"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2023-41721",
"datePublished": "2023-10-25T00:24:34.072Z",
"dateReserved": "2023-08-31T01:00:11.771Z",
"dateUpdated": "2024-09-13T16:28:08.626Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-32000 (GCVE-0-2023-32000)
Vulnerability from nvd – Published: 2023-07-07 23:07 – Updated: 2024-10-21 21:11
VLAI
Summary
A Cross-Site Scripting (XSS) vulnerability found in UniFi Network (Version 7.3.83 and earlier) allows a malicious actor with Site Administrator credentials to escalate privileges by persuading an Administrator to visit a malicious web page.
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti | UniFi Network Application |
Affected:
7.3.83 , ≤ 7.3.83
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:03:28.687Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-034-034/53cfcb84-b42b-4f8f-afbf-07c0ca7cabe2"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-32000",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-21T21:06:57.989361Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-21T21:11:02.916Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Network Application",
"vendor": "Ubiquiti",
"versions": [
{
"lessThanOrEqual": "7.3.83",
"status": "affected",
"version": "7.3.83",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A Cross-Site Scripting (XSS) vulnerability found in UniFi Network (Version 7.3.83 and earlier) allows a malicious actor with Site Administrator credentials to escalate privileges by persuading an Administrator to visit a malicious web page."
}
],
"providerMetadata": {
"dateUpdated": "2023-07-07T23:07:53.212Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-034-034/53cfcb84-b42b-4f8f-afbf-07c0ca7cabe2"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2023-32000",
"datePublished": "2023-07-07T23:07:53.212Z",
"dateReserved": "2023-05-01T01:00:12.219Z",
"dateUpdated": "2024-10-21T21:11:02.916Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-28365 (GCVE-0-2023-28365)
Vulnerability from nvd – Published: 2023-06-30 23:40 – Updated: 2024-11-27 17:23
VLAI
Summary
A backup file vulnerability found in UniFi applications (Version 7.3.83 and earlier) running on Linux operating systems allows application administrators to execute malicious commands on the host device being restored.
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti Inc. | UniFi Network application |
Affected:
7.3.83 , ≤ 7.3.83
(semver)
|
|
| ubiquiti | unifi_network_application |
Affected:
0 , ≤ 7.3.83
(semver)
cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:38:25.371Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-031-031/8c85fc64-e9a8-4082-9ec4-56b14effd545"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_network_application:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "unifi_network_application",
"vendor": "ubiquiti",
"versions": [
{
"lessThanOrEqual": "7.3.83",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-28365",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-27T17:22:20.390330Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-27T17:23:23.036Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Network application",
"vendor": "Ubiquiti Inc.",
"versions": [
{
"lessThanOrEqual": "7.3.83",
"status": "affected",
"version": "7.3.83",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A backup file vulnerability found in UniFi applications (Version 7.3.83 and earlier) running on Linux operating systems allows application administrators to execute malicious commands on the host device being restored."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-30T23:40:13.388Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-031-031/8c85fc64-e9a8-4082-9ec4-56b14effd545"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2023-28365",
"datePublished": "2023-06-30T23:40:13.388Z",
"dateReserved": "2023-03-15T01:00:13.221Z",
"dateUpdated": "2024-11-27T17:23:23.036Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}