CVE-2023-32000 (GCVE-0-2023-32000)

Vulnerability from cvelistv5 – Published: 2023-07-07 23:07 – Updated: 2024-10-21 21:11
VLAI?
Summary
A Cross-Site Scripting (XSS) vulnerability found in UniFi Network (Version 7.3.83 and earlier) allows a malicious actor with Site Administrator credentials to escalate privileges by persuading an Administrator to visit a malicious web page.
Severity ?
No CVSS data available.
Assigner
Impacted products
Vendor Product Version
Ubiquiti UniFi Network Application Affected: 7.3.83 , ≤ 7.3.83 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T15:03:28.687Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://community.ui.com/releases/Security-Advisory-Bulletin-034-034/53cfcb84-b42b-4f8f-afbf-07c0ca7cabe2"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-32000",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-21T21:06:57.989361Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-21T21:11:02.916Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "UniFi Network Application",
          "vendor": "Ubiquiti",
          "versions": [
            {
              "lessThanOrEqual": "7.3.83",
              "status": "affected",
              "version": "7.3.83",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A Cross-Site Scripting (XSS) vulnerability found in UniFi Network (Version 7.3.83 and earlier) allows a malicious actor with Site Administrator credentials to escalate privileges by persuading an Administrator to visit a malicious web page."
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-07-07T23:07:53.212Z",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "url": "https://community.ui.com/releases/Security-Advisory-Bulletin-034-034/53cfcb84-b42b-4f8f-afbf-07c0ca7cabe2"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2023-32000",
    "datePublished": "2023-07-07T23:07:53.212Z",
    "dateReserved": "2023-05-01T01:00:12.219Z",
    "dateUpdated": "2024-10-21T21:11:02.916Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ui:unifi_network_application:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"7.3.83\", \"matchCriteriaId\": \"774144E6-A8A1-44A4-B5F6-375397A86FB8\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A Cross-Site Scripting (XSS) vulnerability found in UniFi Network (Version 7.3.83 and earlier) allows a malicious actor with Site Administrator credentials to escalate privileges by persuading an Administrator to visit a malicious web page.\"}]",
      "id": "CVE-2023-32000",
      "lastModified": "2024-11-21T08:02:30.230",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 4.8, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.7, \"impactScore\": 2.7}]}",
      "published": "2023-07-08T00:15:09.653",
      "references": "[{\"url\": \"https://community.ui.com/releases/Security-Advisory-Bulletin-034-034/53cfcb84-b42b-4f8f-afbf-07c0ca7cabe2\", \"source\": \"support@hackerone.com\", \"tags\": [\"Issue Tracking\", \"Vendor Advisory\"]}, {\"url\": \"https://community.ui.com/releases/Security-Advisory-Bulletin-034-034/53cfcb84-b42b-4f8f-afbf-07c0ca7cabe2\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Issue Tracking\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-32000\",\"sourceIdentifier\":\"support@hackerone.com\",\"published\":\"2023-07-08T00:15:09.653\",\"lastModified\":\"2024-11-21T08:02:30.230\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A Cross-Site Scripting (XSS) vulnerability found in UniFi Network (Version 7.3.83 and earlier) allows a malicious actor with Site Administrator credentials to escalate privileges by persuading an Administrator to visit a malicious web page.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":4.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.7,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ui:unifi_network_application:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.3.83\",\"matchCriteriaId\":\"774144E6-A8A1-44A4-B5F6-375397A86FB8\"}]}]}],\"references\":[{\"url\":\"https://community.ui.com/releases/Security-Advisory-Bulletin-034-034/53cfcb84-b42b-4f8f-afbf-07c0ca7cabe2\",\"source\":\"support@hackerone.com\",\"tags\":[\"Issue Tracking\",\"Vendor Advisory\"]},{\"url\":\"https://community.ui.com/releases/Security-Advisory-Bulletin-034-034/53cfcb84-b42b-4f8f-afbf-07c0ca7cabe2\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Issue Tracking\",\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://community.ui.com/releases/Security-Advisory-Bulletin-034-034/53cfcb84-b42b-4f8f-afbf-07c0ca7cabe2\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T15:03:28.687Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-32000\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-21T21:06:57.989361Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-21T21:08:28.851Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"Ubiquiti\", \"product\": \"UniFi Network Application\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.3.83\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.3.83\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://community.ui.com/releases/Security-Advisory-Bulletin-034-034/53cfcb84-b42b-4f8f-afbf-07c0ca7cabe2\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A Cross-Site Scripting (XSS) vulnerability found in UniFi Network (Version 7.3.83 and earlier) allows a malicious actor with Site Administrator credentials to escalate privileges by persuading an Administrator to visit a malicious web page.\"}], \"providerMetadata\": {\"orgId\": \"36234546-b8fa-4601-9d6f-f4e334aa8ea1\", \"shortName\": \"hackerone\", \"dateUpdated\": \"2023-07-07T23:07:53.212Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-32000\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-10-21T21:11:02.916Z\", \"dateReserved\": \"2023-05-01T01:00:12.219Z\", \"assignerOrgId\": \"36234546-b8fa-4601-9d6f-f4e334aa8ea1\", \"datePublished\": \"2023-07-07T23:07:53.212Z\", \"assignerShortName\": \"hackerone\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.