Search criteria
51 vulnerabilities found for unisphere_for_powermax_virtual_appliance by dell
FKIE_CVE-2025-36589
Vulnerability from fkie_nvd - Published: 2026-01-06 17:15 - Updated: 2026-01-22 20:44
Severity ?
7.6 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L
7.1 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N
7.1 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N
Summary
Dell Unisphere for PowerMax, version(s) 9.2.4.x, contain(s) an Improper Restriction of XML External Entity Reference vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to unauthorized access to data and resources outside of the intended sphere of control.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | unisphere_for_powermax | 9.2.4.18 | |
| dell | unisphere_for_powermax_virtual_appliance | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:unisphere_for_powermax:9.2.4.18:*:*:*:*:*:*:*",
"matchCriteriaId": "91E090BB-DB5B-428A-86E5-CD435AEF6360",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:unisphere_for_powermax_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "51C6E69D-6294-4181-BF67-CEE8075371FA",
"versionEndExcluding": "9.2.4.19",
"versionStartIncluding": "9.2.4.17",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell Unisphere for PowerMax, version(s) 9.2.4.x, contain(s) an Improper Restriction of XML External Entity Reference vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to unauthorized access to data and resources outside of the intended sphere of control."
}
],
"id": "CVE-2025-36589",
"lastModified": "2026-01-22T20:44:14.520",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 4.7,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 4.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2026-01-06T17:15:43.780",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000402262/dsa-2025-425-dell-powermaxos-dell-powermax-eem-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-unisphere-360-dell-solutions-enabler-virtual-appliance-security-update-for-multiple-vulnerabilities"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-611"
}
],
"source": "security_alert@emc.com",
"type": "Primary"
}
]
}
FKIE_CVE-2025-36595
Vulnerability from fkie_nvd - Published: 2025-06-27 14:15 - Updated: 2026-01-14 18:52
Severity ?
Summary
Dell Unisphere for PowerMax vApp, version(s) 9.2.4.x, contain(s) an Improper Neutralization of Directives in Statically Saved Code ('Static Code Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Code execution.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | solutions_enabler_virtual_appliance | * | |
| dell | unisphere_for_powermax_virtual_appliance | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:solutions_enabler_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8E024408-60EF-412A-AA63-18571721F5D2",
"versionEndExcluding": "9.2.4.11",
"versionStartIncluding": "9.2.4.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:unisphere_for_powermax_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACF1FAA6-FEDF-40B1-ACBC-9AE565671F4A",
"versionEndExcluding": "9.2.4.17",
"versionStartIncluding": "9.2.4.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell Unisphere for PowerMax vApp, version(s) 9.2.4.x, contain(s) an Improper Neutralization of Directives in Statically Saved Code (\u0027Static Code Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Code execution."
},
{
"lang": "es",
"value": "Dell Unisphere para PowerMax vApp, versi\u00f3n 9.2.4.x, presenta una vulnerabilidad de neutralizaci\u00f3n incorrecta de directivas en c\u00f3digo guardado est\u00e1ticamente (inyecci\u00f3n de c\u00f3digo est\u00e1tico). Un atacante con privilegios elevados y acceso remoto podr\u00eda explotar esta vulnerabilidad, lo que provocar\u00eda la ejecuci\u00f3n del c\u00f3digo."
}
],
"id": "CVE-2025-36595",
"lastModified": "2026-01-14T18:52:37.360",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "security_alert@emc.com",
"type": "Secondary"
}
]
},
"published": "2025-06-27T14:15:36.517",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000337554/dsa-2025-235-dell-powermaxos-dell-powermax-eem-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-unisphere-360-dell-solutions-enabler-and-dell-solutions-enabler-virtual-appliance-security-update-for-multiple-vulnerabilit"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-96"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-25946
Vulnerability from fkie_nvd - Published: 2024-03-28 19:15 - Updated: 2025-01-27 18:57
Severity ?
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | powermax_eem | 5978 | |
| dell | solutions_enabler_virtual_appliance | * | |
| dell | unisphere_for_powermax_virtual_appliance | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:powermax_eem:5978:*:*:*:*:*:*:*",
"matchCriteriaId": "A6945B14-B9EC-41C3-9F62-623A3034140B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:solutions_enabler_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "880C4ED7-3D39-4FFF-A35A-49D249A544CF",
"versionEndExcluding": "9.2.4.6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:unisphere_for_powermax_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "424665FA-37F4-4D36-91CC-0CDAC4749912",
"versionEndExcluding": "9.2.4.9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity."
},
{
"lang": "es",
"value": "Dell vApp Manager, las versiones anteriores a la 9.2.4.9 contienen una vulnerabilidad de inyecci\u00f3n de comandos. Un atacante autorizado podr\u00eda explotar esta vulnerabilidad y llevar a la ejecuci\u00f3n de un comando insertado. Dell recomienda a los clientes actualizar lo antes posible."
}
],
"id": "CVE-2024-25946",
"lastModified": "2025-01-27T18:57:59.197",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2024-03-28T19:15:47.010",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2024-25955
Vulnerability from fkie_nvd - Published: 2024-03-28 19:15 - Updated: 2025-01-27 18:57
Severity ?
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | powermax_eem | 5978 | |
| dell | solutions_enabler_virtual_appliance | * | |
| dell | unisphere_for_powermax_virtual_appliance | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:powermax_eem:5978:*:*:*:*:*:*:*",
"matchCriteriaId": "A6945B14-B9EC-41C3-9F62-623A3034140B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:solutions_enabler_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "880C4ED7-3D39-4FFF-A35A-49D249A544CF",
"versionEndExcluding": "9.2.4.6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:unisphere_for_powermax_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "424665FA-37F4-4D36-91CC-0CDAC4749912",
"versionEndExcluding": "9.2.4.9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity."
},
{
"lang": "es",
"value": "Dell vApp Manager, las versiones anteriores a la 9.2.4.9 contienen una vulnerabilidad de inyecci\u00f3n de comandos. Un atacante autorizado podr\u00eda explotar esta vulnerabilidad y llevar a la ejecuci\u00f3n de un comando insertado. Dell recomienda a los clientes actualizar lo antes posible."
}
],
"id": "CVE-2024-25955",
"lastModified": "2025-01-27T18:57:51.763",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2024-03-28T19:15:47.790",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-48671
Vulnerability from fkie_nvd - Published: 2023-12-14 17:15 - Updated: 2024-11-21 08:32
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Summary
Dell vApp Manager, versions prior to 9.2.4.x contain an information disclosure vulnerability. A remote attacker could potentially exploit this vulnerability leading to obtain sensitive information that may aid in further attacks.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | solutions_enabler_virtual_appliance | * | |
| dell | unisphere_for_powermax_virtual_appliance | * | |
| dell | powermax_os | 5978 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:solutions_enabler_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A66644ED-0329-4D52-BF77-46FC55D0E509",
"versionEndExcluding": "9.2.4.5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:unisphere_for_powermax_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F7A1C0B1-1991-4B65-8246-CBD559A577B0",
"versionEndExcluding": "9.2.4.7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:dell:powermax_os:5978:*:*:*:eem:*:*:*",
"matchCriteriaId": "8236D1AC-66D0-4BEE-B9DB-C8B2DACE0400",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\nDell vApp Manager, versions prior to 9.2.4.x contain an information disclosure vulnerability. A remote attacker could potentially exploit this vulnerability leading to obtain sensitive information that may aid in further attacks.\n\n"
},
{
"lang": "es",
"value": "Dell vApp Manager, las versiones anteriores a la 9.2.4.x contienen una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n. Un atacante remoto podr\u00eda explotar esta vulnerabilidad y obtener informaci\u00f3n confidencial que podr\u00eda ayudar en futuros ataques."
}
],
"id": "CVE-2023-48671",
"lastModified": "2024-11-21T08:32:14.137",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-12-14T17:15:07.987",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-200"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-48662
Vulnerability from fkie_nvd - Published: 2023-12-14 16:15 - Updated: 2024-11-21 08:32
Severity ?
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Summary
Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | solutions_enabler_virtual_appliance | * | |
| dell | unisphere_for_powermax_virtual_appliance | * | |
| dell | powermax_os | 5978 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:solutions_enabler_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A66644ED-0329-4D52-BF77-46FC55D0E509",
"versionEndExcluding": "9.2.4.5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:unisphere_for_powermax_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F7A1C0B1-1991-4B65-8246-CBD559A577B0",
"versionEndExcluding": "9.2.4.7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:dell:powermax_os:5978:*:*:*:eem:*:*:*",
"matchCriteriaId": "8236D1AC-66D0-4BEE-B9DB-C8B2DACE0400",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\nDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\n\n"
},
{
"lang": "es",
"value": "Dell vApp Manager, las versiones anteriores a 9.2.4.x contienen una vulnerabilidad de inyecci\u00f3n de comandos. Un usuario malicioso remoto con altos privilegios podr\u00eda explotar esta vulnerabilidad y llevar a la ejecuci\u00f3n de comandos arbitrarios del sistema operativo en el sistema afectado."
}
],
"id": "CVE-2023-48662",
"lastModified": "2024-11-21T08:32:13.250",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-12-14T16:15:49.227",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-48661
Vulnerability from fkie_nvd - Published: 2023-12-14 16:15 - Updated: 2024-11-21 08:32
Severity ?
4.9 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
4.9 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
4.9 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
Summary
Dell vApp Manager, versions prior to 9.2.4.x contain an arbitrary file read vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability to read arbitrary files from the target system.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | solutions_enabler_virtual_appliance | * | |
| dell | unisphere_for_powermax_virtual_appliance | * | |
| dell | powermax_os | 5978 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:solutions_enabler_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A66644ED-0329-4D52-BF77-46FC55D0E509",
"versionEndExcluding": "9.2.4.5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:unisphere_for_powermax_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F7A1C0B1-1991-4B65-8246-CBD559A577B0",
"versionEndExcluding": "9.2.4.7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:dell:powermax_os:5978:*:*:*:eem:*:*:*",
"matchCriteriaId": "8236D1AC-66D0-4BEE-B9DB-C8B2DACE0400",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\nDell vApp Manager, versions prior to 9.2.4.x contain an arbitrary file read vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability to read arbitrary files from the target system.\n\n"
},
{
"lang": "es",
"value": "Dell vApp Manager, las versiones anteriores a 9.2.4.x contienen una vulnerabilidad de lectura de archivos arbitraria. Un usuario malicioso remoto con altos privilegios podr\u00eda explotar esta vulnerabilidad para leer archivos arbitrarios del sistema de destino."
}
],
"id": "CVE-2023-48661",
"lastModified": "2024-11-21T08:32:13.113",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 3.6,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-12-14T16:15:49.023",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-552"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-552"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-48665
Vulnerability from fkie_nvd - Published: 2023-12-14 16:15 - Updated: 2024-11-21 08:32
Severity ?
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Summary
Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | solutions_enabler_virtual_appliance | * | |
| dell | unisphere_for_powermax_virtual_appliance | * | |
| dell | powermax_os | 5978 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:solutions_enabler_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A66644ED-0329-4D52-BF77-46FC55D0E509",
"versionEndExcluding": "9.2.4.5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:unisphere_for_powermax_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F7A1C0B1-1991-4B65-8246-CBD559A577B0",
"versionEndExcluding": "9.2.4.7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:dell:powermax_os:5978:*:*:*:eem:*:*:*",
"matchCriteriaId": "8236D1AC-66D0-4BEE-B9DB-C8B2DACE0400",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\nDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\n\n"
},
{
"lang": "es",
"value": "Dell vApp Manager, las versiones anteriores a 9.2.4.x contienen una vulnerabilidad de inyecci\u00f3n de comandos. Un usuario malicioso remoto con altos privilegios podr\u00eda explotar esta vulnerabilidad y llevar a la ejecuci\u00f3n de comandos arbitrarios del sistema operativo en el sistema afectado."
}
],
"id": "CVE-2023-48665",
"lastModified": "2024-11-21T08:32:13.603",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-12-14T16:15:49.847",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-48663
Vulnerability from fkie_nvd - Published: 2023-12-14 16:15 - Updated: 2024-11-21 08:32
Severity ?
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Summary
Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | solutions_enabler_virtual_appliance | * | |
| dell | unisphere_for_powermax_virtual_appliance | * | |
| dell | powermax_os | 5978 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:solutions_enabler_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A66644ED-0329-4D52-BF77-46FC55D0E509",
"versionEndExcluding": "9.2.4.5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:unisphere_for_powermax_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F7A1C0B1-1991-4B65-8246-CBD559A577B0",
"versionEndExcluding": "9.2.4.7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:dell:powermax_os:5978:*:*:*:eem:*:*:*",
"matchCriteriaId": "8236D1AC-66D0-4BEE-B9DB-C8B2DACE0400",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\nDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\n\n"
},
{
"lang": "es",
"value": "Dell vApp Manager, las versiones anteriores a 9.2.4.x contienen una vulnerabilidad de inyecci\u00f3n de comandos. Un usuario malicioso remoto con altos privilegios podr\u00eda explotar esta vulnerabilidad y llevar a la ejecuci\u00f3n de comandos arbitrarios del sistema operativo en el sistema afectado."
}
],
"id": "CVE-2023-48663",
"lastModified": "2024-11-21T08:32:13.377",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-12-14T16:15:49.433",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-48664
Vulnerability from fkie_nvd - Published: 2023-12-14 16:15 - Updated: 2024-11-21 08:32
Severity ?
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Summary
Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | solutions_enabler_virtual_appliance | * | |
| dell | unisphere_for_powermax_virtual_appliance | * | |
| dell | powermax_os | 5978 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:solutions_enabler_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A66644ED-0329-4D52-BF77-46FC55D0E509",
"versionEndExcluding": "9.2.4.5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:unisphere_for_powermax_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F7A1C0B1-1991-4B65-8246-CBD559A577B0",
"versionEndExcluding": "9.2.4.7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:dell:powermax_os:5978:*:*:*:eem:*:*:*",
"matchCriteriaId": "8236D1AC-66D0-4BEE-B9DB-C8B2DACE0400",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\nDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\n\n"
},
{
"lang": "es",
"value": "Dell vApp Manager, las versiones anteriores a 9.2.4.x contienen una vulnerabilidad de inyecci\u00f3n de comandos. Un usuario malicioso remoto con altos privilegios podr\u00eda explotar esta vulnerabilidad y llevar a la ejecuci\u00f3n de comandos arbitrarios del sistema operativo en el sistema afectado."
}
],
"id": "CVE-2023-48664",
"lastModified": "2024-11-21T08:32:13.500",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-12-14T16:15:49.640",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-48660
Vulnerability from fkie_nvd - Published: 2023-12-14 16:15 - Updated: 2024-11-21 08:32
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Summary
Dell vApp Manger, versions prior to 9.2.4.x contain an arbitrary file read vulnerability. A remote attacker could potentially exploit this vulnerability to read arbitrary files from the target system.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | solutions_enabler_virtual_appliance | * | |
| dell | unisphere_for_powermax_virtual_appliance | * | |
| dell | powermax_os | 5978 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:solutions_enabler_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A66644ED-0329-4D52-BF77-46FC55D0E509",
"versionEndExcluding": "9.2.4.5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:unisphere_for_powermax_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F7A1C0B1-1991-4B65-8246-CBD559A577B0",
"versionEndExcluding": "9.2.4.7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:dell:powermax_os:5978:*:*:*:eem:*:*:*",
"matchCriteriaId": "8236D1AC-66D0-4BEE-B9DB-C8B2DACE0400",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\nDell vApp Manger, versions prior to 9.2.4.x contain an arbitrary file read vulnerability. A remote attacker could potentially exploit this vulnerability to read arbitrary files from the target system.\n\n"
},
{
"lang": "es",
"value": "Dell vApp Manager, las versiones anteriores a 9.2.4.x contienen una vulnerabilidad de lectura de archivos arbitraria. Un atacante remoto podr\u00eda explotar esta vulnerabilidad para leer archivos arbitrarios del sistema de destino."
}
],
"id": "CVE-2023-48660",
"lastModified": "2024-11-21T08:32:12.970",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-12-14T16:15:48.823",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2025-36589 (GCVE-0-2025-36589)
Vulnerability from nvd – Published: 2026-01-06 16:20 – Updated: 2026-01-06 16:55
VLAI?
Summary
Dell Unisphere for PowerMax, version(s) 9.2.4.x, contain(s) an Improper Restriction of XML External Entity Reference vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to unauthorized access to data and resources outside of the intended sphere of control.
Severity ?
7.6 (High)
CWE
- CWE-611 - Improper Restriction of XML External Entity Reference
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Unisphere for PowerMax |
Affected:
N/A , < 9.2.4.19
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-36589",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-06T16:54:46.931803Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-06T16:55:17.429Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Unisphere for PowerMax",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.2.4.19",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"datePublic": "2025-12-19T18:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Unisphere for PowerMax, version(s) 9.2.4.x, contain(s) an Improper Restriction of XML External Entity Reference vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to unauthorized access to data and resources outside of the intended sphere of control."
}
],
"value": "Dell Unisphere for PowerMax, version(s) 9.2.4.x, contain(s) an Improper Restriction of XML External Entity Reference vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to unauthorized access to data and resources outside of the intended sphere of control."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-611",
"description": "CWE-611: Improper Restriction of XML External Entity Reference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-06T16:20:24.899Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000402262/dsa-2025-425-dell-powermaxos-dell-powermax-eem-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-unisphere-360-dell-solutions-enabler-virtual-appliance-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2025-36589",
"datePublished": "2026-01-06T16:20:24.899Z",
"dateReserved": "2025-04-15T21:31:17.347Z",
"dateUpdated": "2026-01-06T16:55:17.429Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-36595 (GCVE-0-2025-36595)
Vulnerability from nvd – Published: 2025-06-27 13:51 – Updated: 2025-06-28 03:55
VLAI?
Summary
Dell Unisphere for PowerMax vApp, version(s) 9.2.4.x, contain(s) an Improper Neutralization of Directives in Statically Saved Code ('Static Code Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Code execution.
Severity ?
7.2 (High)
CWE
- CWE-96 - Improper Neutralization of Directives in Statically Saved Code ('Static Code Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Unisphere for PowerMax vApp |
Affected:
NA , < 9.2.4.17
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-36595",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-27T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-28T03:55:25.484Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Unisphere for PowerMax vApp",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.2.4.17",
"status": "affected",
"version": "NA",
"versionType": "semver"
}
]
}
],
"datePublic": "2025-06-26T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Unisphere for PowerMax vApp, version(s) 9.2.4.x, contain(s) an Improper Neutralization of Directives in Statically Saved Code (\u0027Static Code Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Code execution.\u003cbr\u003e"
}
],
"value": "Dell Unisphere for PowerMax vApp, version(s) 9.2.4.x, contain(s) an Improper Neutralization of Directives in Statically Saved Code (\u0027Static Code Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Code execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-96",
"description": "CWE-96: Improper Neutralization of Directives in Statically Saved Code (\u0027Static Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-27T13:51:28.738Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000337554/dsa-2025-235-dell-powermaxos-dell-powermax-eem-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-unisphere-360-dell-solutions-enabler-and-dell-solutions-enabler-virtual-appliance-security-update-for-multiple-vulnerabilit"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2025-36595",
"datePublished": "2025-06-27T13:51:28.738Z",
"dateReserved": "2025-04-15T21:32:11.413Z",
"dateUpdated": "2025-06-28T03:55:25.484Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-25955 (GCVE-0-2024-25955)
Vulnerability from nvd – Published: 2024-03-28 19:05 – Updated: 2024-08-01 23:52
VLAI?
Summary
Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Virtual Appliance (vApp) Manager |
Affected:
N/A , < 9.2.4.9
(semver)
Affected: N/A , < 9.2.4.6 (semver) Affected: N/A , < 5978 (semver) |
Credits
Dell Technologies would like to thank 33a6099 for reporting these issues.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:dell:unisphere_for_powermax_virtual_appliance:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unisphere_for_powermax_virtual_appliance",
"vendor": "dell",
"versions": [
{
"lessThan": "9.2.4.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:dell:solutions_enabler_virtual_appliance:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "solutions_enabler_virtual_appliance",
"vendor": "dell",
"versions": [
{
"lessThan": "9.2.4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:dell:unisphere_for_powermax:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unisphere_for_powermax",
"vendor": "dell",
"versions": [
{
"lessThan": "5978",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-25955",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-08T17:44:26.390852Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-20T18:39:13.355Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T23:52:06.240Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Virtual Appliance (vApp) Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.2.4.9",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "9.2.4.6",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "5978",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell Technologies would like to thank 33a6099 for reporting these issues. "
}
],
"datePublic": "2024-03-28T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity."
}
],
"value": "Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-28T19:05:10.021Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-25955",
"datePublished": "2024-03-28T19:05:10.021Z",
"dateReserved": "2024-02-13T05:32:19.480Z",
"dateUpdated": "2024-08-01T23:52:06.240Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-25946 (GCVE-0-2024-25946)
Vulnerability from nvd – Published: 2024-03-28 19:00 – Updated: 2025-03-25 14:43
VLAI?
Summary
Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Virtual Appliance (vApp) Manager |
Affected:
N/A , < 9.2.4.9
(semver)
Affected: N/A , < 9.2.4.6 (semver) Affected: N/A , < 5978 (semver) |
Credits
Dell Technologies would like to thank 33a6099 for reporting these issues
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:dell:virtual_appliance_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "virtual_appliance_manager",
"vendor": "dell",
"versions": [
{
"lessThan": "9.2.4.9",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "9.2.4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "5978",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-25946",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-28T19:38:49.231622Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T14:43:03.457Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T23:52:06.416Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Virtual Appliance (vApp) Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.2.4.9",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "9.2.4.6",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "5978",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell Technologies would like to thank 33a6099 for reporting these issues"
}
],
"datePublic": "2024-03-28T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity."
}
],
"value": "Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-28T19:00:18.175Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-25946",
"datePublished": "2024-03-28T19:00:18.175Z",
"dateReserved": "2024-02-13T05:29:58.481Z",
"dateUpdated": "2025-03-25T14:43:03.457Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48671 (GCVE-0-2023-48671)
Vulnerability from nvd – Published: 2023-12-14 16:15 – Updated: 2024-08-02 21:37
VLAI?
Summary
Dell vApp Manager, versions prior to 9.2.4.x contain an information disclosure vulnerability. A remote attacker could potentially exploit this vulnerability leading to obtain sensitive information that may aid in further attacks.
Severity ?
7.5 (High)
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | vApp Manager |
Affected:
Versions prior to 9.2.4.x
|
Credits
Dell Technologies would like to thank 33a6099 for reporting these issues.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:37:54.246Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "vApp Manager",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 9.2.4.x"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Dell Technologies would like to thank 33a6099 for reporting these issues. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell vApp Manager, versions prior to 9.2.4.x contain an information disclosure vulnerability. A remote attacker could potentially exploit this vulnerability leading to obtain sensitive information that may aid in further attacks.\u003c/span\u003e\n\n"
}
],
"value": "\nDell vApp Manager, versions prior to 9.2.4.x contain an information disclosure vulnerability. A remote attacker could potentially exploit this vulnerability leading to obtain sensitive information that may aid in further attacks.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T16:15:29.756Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-48671",
"datePublished": "2023-12-14T16:15:29.756Z",
"dateReserved": "2023-11-17T06:17:23.509Z",
"dateUpdated": "2024-08-02T21:37:54.246Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48665 (GCVE-0-2023-48665)
Vulnerability from nvd – Published: 2023-12-14 16:12 – Updated: 2024-08-02 21:37
VLAI?
Summary
Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | vApp Manager, |
Affected:
Versions prior to 9.2.4.x
|
Credits
Dell Technologies would like to thank 33a6099 for reporting these issues.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:37:54.654Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "vApp Manager,",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 9.2.4.x"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Dell Technologies would like to thank 33a6099 for reporting these issues. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\u003c/span\u003e\n\n"
}
],
"value": "\nDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T16:12:20.442Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-48665",
"datePublished": "2023-12-14T16:12:20.442Z",
"dateReserved": "2023-11-17T06:14:57.041Z",
"dateUpdated": "2024-08-02T21:37:54.654Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48664 (GCVE-0-2023-48664)
Vulnerability from nvd – Published: 2023-12-14 16:08 – Updated: 2024-08-02 21:37
VLAI?
Summary
Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | vApp Manager |
Affected:
Versions prior to 9.2.4.x
|
Credits
Dell Technologies would like to thank 33a6099 for reporting these issues.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:37:53.448Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "vApp Manager",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 9.2.4.x"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Dell Technologies would like to thank 33a6099 for reporting these issues. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\u003c/span\u003e\n\n"
}
],
"value": "\nDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T16:08:11.100Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-48664",
"datePublished": "2023-12-14T16:08:11.100Z",
"dateReserved": "2023-11-17T06:14:57.041Z",
"dateUpdated": "2024-08-02T21:37:53.448Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48663 (GCVE-0-2023-48663)
Vulnerability from nvd – Published: 2023-12-14 16:03 – Updated: 2025-05-21 14:36
VLAI?
Summary
Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | vApp Manager |
Affected:
Versions prior to 9.2.4.x
|
Credits
Dell Technologies would like to thank 33a6099 for reporting these issues.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:37:54.378Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-48663",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-21T14:35:53.399302Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-21T14:36:07.199Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "vApp Manager",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 9.2.4.x"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Dell Technologies would like to thank 33a6099 for reporting these issues. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\u003c/span\u003e\n\n"
}
],
"value": "\nDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T16:03:27.167Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-48663",
"datePublished": "2023-12-14T16:03:27.167Z",
"dateReserved": "2023-11-17T06:14:57.041Z",
"dateUpdated": "2025-05-21T14:36:07.199Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48662 (GCVE-0-2023-48662)
Vulnerability from nvd – Published: 2023-12-14 15:59 – Updated: 2024-08-02 21:37
VLAI?
Summary
Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | vApp Manager |
Affected:
Versions prior to 9.2.4.x
|
Credits
Dell Technologies would like to thank 33a6099 for reporting these issues.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:37:53.585Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "vApp Manager",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 9.2.4.x"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Dell Technologies would like to thank 33a6099 for reporting these issues. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\u003c/span\u003e\n\n"
}
],
"value": "\nDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T15:59:26.417Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-48662",
"datePublished": "2023-12-14T15:59:26.417Z",
"dateReserved": "2023-11-17T06:14:57.041Z",
"dateUpdated": "2024-08-02T21:37:53.585Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-36589 (GCVE-0-2025-36589)
Vulnerability from cvelistv5 – Published: 2026-01-06 16:20 – Updated: 2026-01-06 16:55
VLAI?
Summary
Dell Unisphere for PowerMax, version(s) 9.2.4.x, contain(s) an Improper Restriction of XML External Entity Reference vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to unauthorized access to data and resources outside of the intended sphere of control.
Severity ?
7.6 (High)
CWE
- CWE-611 - Improper Restriction of XML External Entity Reference
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Unisphere for PowerMax |
Affected:
N/A , < 9.2.4.19
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-36589",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-06T16:54:46.931803Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-06T16:55:17.429Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Unisphere for PowerMax",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.2.4.19",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"datePublic": "2025-12-19T18:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Unisphere for PowerMax, version(s) 9.2.4.x, contain(s) an Improper Restriction of XML External Entity Reference vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to unauthorized access to data and resources outside of the intended sphere of control."
}
],
"value": "Dell Unisphere for PowerMax, version(s) 9.2.4.x, contain(s) an Improper Restriction of XML External Entity Reference vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to unauthorized access to data and resources outside of the intended sphere of control."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-611",
"description": "CWE-611: Improper Restriction of XML External Entity Reference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-06T16:20:24.899Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000402262/dsa-2025-425-dell-powermaxos-dell-powermax-eem-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-unisphere-360-dell-solutions-enabler-virtual-appliance-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2025-36589",
"datePublished": "2026-01-06T16:20:24.899Z",
"dateReserved": "2025-04-15T21:31:17.347Z",
"dateUpdated": "2026-01-06T16:55:17.429Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-36595 (GCVE-0-2025-36595)
Vulnerability from cvelistv5 – Published: 2025-06-27 13:51 – Updated: 2025-06-28 03:55
VLAI?
Summary
Dell Unisphere for PowerMax vApp, version(s) 9.2.4.x, contain(s) an Improper Neutralization of Directives in Statically Saved Code ('Static Code Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Code execution.
Severity ?
7.2 (High)
CWE
- CWE-96 - Improper Neutralization of Directives in Statically Saved Code ('Static Code Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Unisphere for PowerMax vApp |
Affected:
NA , < 9.2.4.17
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-36595",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-27T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-28T03:55:25.484Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Unisphere for PowerMax vApp",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.2.4.17",
"status": "affected",
"version": "NA",
"versionType": "semver"
}
]
}
],
"datePublic": "2025-06-26T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Unisphere for PowerMax vApp, version(s) 9.2.4.x, contain(s) an Improper Neutralization of Directives in Statically Saved Code (\u0027Static Code Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Code execution.\u003cbr\u003e"
}
],
"value": "Dell Unisphere for PowerMax vApp, version(s) 9.2.4.x, contain(s) an Improper Neutralization of Directives in Statically Saved Code (\u0027Static Code Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Code execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-96",
"description": "CWE-96: Improper Neutralization of Directives in Statically Saved Code (\u0027Static Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-27T13:51:28.738Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000337554/dsa-2025-235-dell-powermaxos-dell-powermax-eem-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-unisphere-360-dell-solutions-enabler-and-dell-solutions-enabler-virtual-appliance-security-update-for-multiple-vulnerabilit"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2025-36595",
"datePublished": "2025-06-27T13:51:28.738Z",
"dateReserved": "2025-04-15T21:32:11.413Z",
"dateUpdated": "2025-06-28T03:55:25.484Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-25955 (GCVE-0-2024-25955)
Vulnerability from cvelistv5 – Published: 2024-03-28 19:05 – Updated: 2024-08-01 23:52
VLAI?
Summary
Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Virtual Appliance (vApp) Manager |
Affected:
N/A , < 9.2.4.9
(semver)
Affected: N/A , < 9.2.4.6 (semver) Affected: N/A , < 5978 (semver) |
Credits
Dell Technologies would like to thank 33a6099 for reporting these issues.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:dell:unisphere_for_powermax_virtual_appliance:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unisphere_for_powermax_virtual_appliance",
"vendor": "dell",
"versions": [
{
"lessThan": "9.2.4.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:dell:solutions_enabler_virtual_appliance:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "solutions_enabler_virtual_appliance",
"vendor": "dell",
"versions": [
{
"lessThan": "9.2.4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:dell:unisphere_for_powermax:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unisphere_for_powermax",
"vendor": "dell",
"versions": [
{
"lessThan": "5978",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-25955",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-08T17:44:26.390852Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-20T18:39:13.355Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T23:52:06.240Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Virtual Appliance (vApp) Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.2.4.9",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "9.2.4.6",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "5978",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell Technologies would like to thank 33a6099 for reporting these issues. "
}
],
"datePublic": "2024-03-28T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity."
}
],
"value": "Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-28T19:05:10.021Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-25955",
"datePublished": "2024-03-28T19:05:10.021Z",
"dateReserved": "2024-02-13T05:32:19.480Z",
"dateUpdated": "2024-08-01T23:52:06.240Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-25946 (GCVE-0-2024-25946)
Vulnerability from cvelistv5 – Published: 2024-03-28 19:00 – Updated: 2025-03-25 14:43
VLAI?
Summary
Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Virtual Appliance (vApp) Manager |
Affected:
N/A , < 9.2.4.9
(semver)
Affected: N/A , < 9.2.4.6 (semver) Affected: N/A , < 5978 (semver) |
Credits
Dell Technologies would like to thank 33a6099 for reporting these issues
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:dell:virtual_appliance_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "virtual_appliance_manager",
"vendor": "dell",
"versions": [
{
"lessThan": "9.2.4.9",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "9.2.4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "5978",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-25946",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-28T19:38:49.231622Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T14:43:03.457Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T23:52:06.416Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Virtual Appliance (vApp) Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.2.4.9",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "9.2.4.6",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "5978",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell Technologies would like to thank 33a6099 for reporting these issues"
}
],
"datePublic": "2024-03-28T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity."
}
],
"value": "Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-28T19:00:18.175Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-25946",
"datePublished": "2024-03-28T19:00:18.175Z",
"dateReserved": "2024-02-13T05:29:58.481Z",
"dateUpdated": "2025-03-25T14:43:03.457Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48671 (GCVE-0-2023-48671)
Vulnerability from cvelistv5 – Published: 2023-12-14 16:15 – Updated: 2024-08-02 21:37
VLAI?
Summary
Dell vApp Manager, versions prior to 9.2.4.x contain an information disclosure vulnerability. A remote attacker could potentially exploit this vulnerability leading to obtain sensitive information that may aid in further attacks.
Severity ?
7.5 (High)
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | vApp Manager |
Affected:
Versions prior to 9.2.4.x
|
Credits
Dell Technologies would like to thank 33a6099 for reporting these issues.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:37:54.246Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "vApp Manager",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 9.2.4.x"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Dell Technologies would like to thank 33a6099 for reporting these issues. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell vApp Manager, versions prior to 9.2.4.x contain an information disclosure vulnerability. A remote attacker could potentially exploit this vulnerability leading to obtain sensitive information that may aid in further attacks.\u003c/span\u003e\n\n"
}
],
"value": "\nDell vApp Manager, versions prior to 9.2.4.x contain an information disclosure vulnerability. A remote attacker could potentially exploit this vulnerability leading to obtain sensitive information that may aid in further attacks.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T16:15:29.756Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-48671",
"datePublished": "2023-12-14T16:15:29.756Z",
"dateReserved": "2023-11-17T06:17:23.509Z",
"dateUpdated": "2024-08-02T21:37:54.246Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48665 (GCVE-0-2023-48665)
Vulnerability from cvelistv5 – Published: 2023-12-14 16:12 – Updated: 2024-08-02 21:37
VLAI?
Summary
Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | vApp Manager, |
Affected:
Versions prior to 9.2.4.x
|
Credits
Dell Technologies would like to thank 33a6099 for reporting these issues.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:37:54.654Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "vApp Manager,",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 9.2.4.x"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Dell Technologies would like to thank 33a6099 for reporting these issues. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\u003c/span\u003e\n\n"
}
],
"value": "\nDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T16:12:20.442Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-48665",
"datePublished": "2023-12-14T16:12:20.442Z",
"dateReserved": "2023-11-17T06:14:57.041Z",
"dateUpdated": "2024-08-02T21:37:54.654Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48664 (GCVE-0-2023-48664)
Vulnerability from cvelistv5 – Published: 2023-12-14 16:08 – Updated: 2024-08-02 21:37
VLAI?
Summary
Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | vApp Manager |
Affected:
Versions prior to 9.2.4.x
|
Credits
Dell Technologies would like to thank 33a6099 for reporting these issues.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:37:53.448Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "vApp Manager",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 9.2.4.x"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Dell Technologies would like to thank 33a6099 for reporting these issues. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\u003c/span\u003e\n\n"
}
],
"value": "\nDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T16:08:11.100Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-48664",
"datePublished": "2023-12-14T16:08:11.100Z",
"dateReserved": "2023-11-17T06:14:57.041Z",
"dateUpdated": "2024-08-02T21:37:53.448Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48663 (GCVE-0-2023-48663)
Vulnerability from cvelistv5 – Published: 2023-12-14 16:03 – Updated: 2025-05-21 14:36
VLAI?
Summary
Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | vApp Manager |
Affected:
Versions prior to 9.2.4.x
|
Credits
Dell Technologies would like to thank 33a6099 for reporting these issues.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:37:54.378Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-48663",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-21T14:35:53.399302Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-21T14:36:07.199Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "vApp Manager",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 9.2.4.x"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Dell Technologies would like to thank 33a6099 for reporting these issues. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\u003c/span\u003e\n\n"
}
],
"value": "\nDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T16:03:27.167Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-48663",
"datePublished": "2023-12-14T16:03:27.167Z",
"dateReserved": "2023-11-17T06:14:57.041Z",
"dateUpdated": "2025-05-21T14:36:07.199Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48662 (GCVE-0-2023-48662)
Vulnerability from cvelistv5 – Published: 2023-12-14 15:59 – Updated: 2024-08-02 21:37
VLAI?
Summary
Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | vApp Manager |
Affected:
Versions prior to 9.2.4.x
|
Credits
Dell Technologies would like to thank 33a6099 for reporting these issues.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:37:53.585Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "vApp Manager",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 9.2.4.x"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Dell Technologies would like to thank 33a6099 for reporting these issues. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\u003c/span\u003e\n\n"
}
],
"value": "\nDell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability leading to the execution of arbitrary OS commands on the affected system.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T15:59:26.417Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-48662",
"datePublished": "2023-12-14T15:59:26.417Z",
"dateReserved": "2023-11-17T06:14:57.041Z",
"dateUpdated": "2024-08-02T21:37:53.585Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48661 (GCVE-0-2023-48661)
Vulnerability from cvelistv5 – Published: 2023-12-14 15:55 – Updated: 2024-08-02 21:37
VLAI?
Summary
Dell vApp Manager, versions prior to 9.2.4.x contain an arbitrary file read vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability to read arbitrary files from the target system.
Severity ?
4.9 (Medium)
CWE
- CWE-552 - Files or Directories Accessible to External Parties
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | vApp Manager |
Affected:
Versions prior to 9.2.4.x
|
Credits
Dell Technologies would like to thank 33a6099 for reporting these issues.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:37:54.426Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "vApp Manager",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 9.2.4.x "
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Dell Technologies would like to thank 33a6099 for reporting these issues. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell vApp Manager, versions prior to 9.2.4.x contain an arbitrary file read vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability to read arbitrary files from the target system.\u003c/span\u003e\n\n"
}
],
"value": "\nDell vApp Manager, versions prior to 9.2.4.x contain an arbitrary file read vulnerability. A remote malicious user with high privileges could potentially exploit this vulnerability to read arbitrary files from the target system.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-552",
"description": "CWE-552: Files or Directories Accessible to External Parties",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T15:55:26.488Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220427/dsa-2023-443-dell-powermaxos-5978-dell-unisphere-360-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-virtual-appliance-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-48661",
"datePublished": "2023-12-14T15:55:26.488Z",
"dateReserved": "2023-11-17T06:14:57.041Z",
"dateUpdated": "2024-08-02T21:37:54.426Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}