9 vulnerabilities found for vampset by schneider-electric

FKIE_CVE-2017-7967

Vulnerability from fkie_nvd - Published: 2017-05-09 17:29 - Updated: 2025-04-20 01:37
Summary
All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corruption vulnerability when a corrupted vf2 file is used. This vulnerability causes the software to halt or not start when trying to open the corrupted file. This vulnerability occurs when fill settings are intentionally malformed and is opened in a standalone state, without connection to a protection relay. This attack is not considered to be remotely exploitable. This vulnerability has no effect on the operation of the protection relay to which VAMPSET is connected. As Windows operating system remains operational and VAMPSET responds, it is able to be shut down through its normal closing protocol.
Impacted products
Vendor Product Version
schneider-electric vampset *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:vampset:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D951553D-F5C3-4853-AE08-155B5EE0AC99",
              "versionEndIncluding": "2.2.185",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corruption vulnerability when a corrupted vf2 file is used. This vulnerability causes the software to halt or not start when trying to open the corrupted file. This vulnerability occurs when fill settings are intentionally malformed and is opened in a standalone state, without connection to a protection relay. This attack is not considered to be remotely exploitable. This vulnerability has no effect on the operation of the protection relay to which VAMPSET is connected. As Windows operating system remains operational and VAMPSET responds, it is able to be shut down through its normal closing protocol."
    },
    {
      "lang": "es",
      "value": "Todas las versiones del software VAMPSET producido por Schneider Electric, anteriores a versi\u00f3n 2.2.189, son susceptibles a una vulnerabilidad de corrupci\u00f3n de memoria cuando se utiliza un archivo vf2 corrupto. Esta vulnerabilidad causa que el software se detenga o no se inicie al intentar abrir el archivo corrupto. Esta vulnerabilidad se produce cuando la configuraci\u00f3n de llenado est\u00e1 malformada intencionalmente y se abre en un estado independiente, sin conexi\u00f3n a un rel\u00e9 de protecci\u00f3n. Este ataque no se considera que sea explotable remotamente. Esta vulnerabilidad no tiene ning\u00fan efecto en la operaci\u00f3n del rel\u00e9 de protecci\u00f3n al que est\u00e1 conectado VAMPSET. A medida que el sistema operativo Windows se mantiene trabajando y VAMPSET responde, es capaz de apagarse por medio de su protocolo de cierre normal."
    }
  ],
  "id": "CVE-2017-7967",
  "lastModified": "2025-04-20T01:37:25.860",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 2.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2017-05-09T17:29:00.213",
  "references": [
    {
      "source": "cybersecurity@se.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-061-01/"
    },
    {
      "source": "cybersecurity@se.com",
      "url": "http://www.securityfocus.com/bid/97124"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-061-01/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/bid/97124"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2014-8390

Vulnerability from fkie_nvd - Published: 2015-04-03 10:59 - Updated: 2025-04-12 10:46

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:vampset:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD962C68-9449-49AB-BD62-F59473AC00A6",
              "versionEndIncluding": "2.2.145",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a (1) CFG or (2) DAT file."
    },
    {
      "lang": "es",
      "value": "M\u00faltiples desbordamientos de buffer en Schneider Electric VAMPSET anterior a 2.2.168 permiten a usuarios locales ganar privilegios a trav\u00e9s de datos que graban disturbios malformados en un fichero (1) CFG o (2) DAT."
    }
  ],
  "id": "CVE-2014-8390",
  "lastModified": "2025-04-12T10:46:40.837",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.4,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.4,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2015-04-03T10:59:03.150",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "http://www.coresecurity.com/advisories/schneider-vampset-stack-and-heap-buffer-overflow"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.schneider-electric.com/ww/en/download/document/SEVD-2015-084-01"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.securityfocus.com/archive/1/535142/100/0/threaded"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.securityfocus.com/bid/73405"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-092-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "http://www.coresecurity.com/advisories/schneider-vampset-stack-and-heap-buffer-overflow"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.schneider-electric.com/ww/en/download/document/SEVD-2015-084-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/archive/1/535142/100/0/threaded"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/bid/73405"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-092-01"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2014-5407

Vulnerability from fkie_nvd - Published: 2014-09-15 14:55 - Updated: 2025-11-03 19:15
Severity ?
Summary
Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.
Impacted products
Vendor Product Version
schneider-electric vampset *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:vampset:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B94A6E8-E88D-4165-850A-754573289558",
              "versionEndIncluding": "2.2.136",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file."
    },
    {
      "lang": "es",
      "value": "M\u00faltiples desbordamientos de buffer basado en pila en Schneider Electric VAMPSET 2.2.136 y anteriores permite a usuarios locales causar una denegaci\u00f3n de servicio (parada de aplicaci\u00f3n) a trav\u00e9s de un (1) fichero de configuraci\u00f3n o (2) fichero de grabaci\u00f3n de disturbio malformados."
    }
  ],
  "id": "CVE-2014-5407",
  "lastModified": "2025-11-03T19:15:38.683",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "LOCAL",
          "authentication": "SINGLE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.1,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:M/Au:S/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 2.7,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary",
        "userInteractionRequired": true
      },
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.4,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.4,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ]
  },
  "published": "2014-09-15T14:55:11.697",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "http://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2014/icsa-14-254-01.json"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-254-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-254-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

CVE-2017-7967 (GCVE-0-2017-7967)

Vulnerability from cvelistv5 – Published: 2017-05-09 17:00 – Updated: 2024-08-05 16:19
VLAI?
Summary
All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corruption vulnerability when a corrupted vf2 file is used. This vulnerability causes the software to halt or not start when trying to open the corrupted file. This vulnerability occurs when fill settings are intentionally malformed and is opened in a standalone state, without connection to a protection relay. This attack is not considered to be remotely exploitable. This vulnerability has no effect on the operation of the protection relay to which VAMPSET is connected. As Windows operating system remains operational and VAMPSET responds, it is able to be shut down through its normal closing protocol.
Severity ?
No CVSS data available.
CWE
  • Memory Corruption
Assigner
References
Impacted products
Vendor Product Version
Schneider Electric SE VAMPSET Affected: All versions prior to 2.2.189
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:19:29.398Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "97124",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/97124"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-061-01/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VAMPSET",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to 2.2.189"
            }
          ]
        }
      ],
      "datePublic": "2017-03-02T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corruption vulnerability when a corrupted vf2 file is used. This vulnerability causes the software to halt or not start when trying to open the corrupted file. This vulnerability occurs when fill settings are intentionally malformed and is opened in a standalone state, without connection to a protection relay. This attack is not considered to be remotely exploitable. This vulnerability has no effect on the operation of the protection relay to which VAMPSET is connected. As Windows operating system remains operational and VAMPSET responds, it is able to be shut down through its normal closing protocol."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Memory Corruption",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-05-22T09:57:01",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "name": "97124",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/97124"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-061-01/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2017-7967",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VAMPSET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions prior to 2.2.189"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corruption vulnerability when a corrupted vf2 file is used. This vulnerability causes the software to halt or not start when trying to open the corrupted file. This vulnerability occurs when fill settings are intentionally malformed and is opened in a standalone state, without connection to a protection relay. This attack is not considered to be remotely exploitable. This vulnerability has no effect on the operation of the protection relay to which VAMPSET is connected. As Windows operating system remains operational and VAMPSET responds, it is able to be shut down through its normal closing protocol."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Memory Corruption"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "97124",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/97124"
            },
            {
              "name": "http://www.schneider-electric.com/en/download/document/SEVD-2017-061-01/",
              "refsource": "CONFIRM",
              "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-061-01/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2017-7967",
    "datePublished": "2017-05-09T17:00:00",
    "dateReserved": "2017-04-19T00:00:00",
    "dateUpdated": "2024-08-05T16:19:29.398Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-8390 (GCVE-0-2014-8390)

Vulnerability from cvelistv5 – Published: 2015-04-03 10:00 – Updated: 2024-08-06 13:18
VLAI?
Summary
Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a (1) CFG or (2) DAT file.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:18:48.295Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20150330 [CORE-2015-0007] - Schneider Vampset Stack and Heap Buffer Overflow",
            "tags": [
              "mailing-list",
              "x_refsource_BUGTRAQ",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/archive/1/535142/100/0/threaded"
          },
          {
            "name": "73405",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/73405"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.coresecurity.com/advisories/schneider-vampset-stack-and-heap-buffer-overflow"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-092-01"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.schneider-electric.com/ww/en/download/document/SEVD-2015-084-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2015-04-02T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a (1) CFG or (2) DAT file."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-09T18:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "20150330 [CORE-2015-0007] - Schneider Vampset Stack and Heap Buffer Overflow",
          "tags": [
            "mailing-list",
            "x_refsource_BUGTRAQ"
          ],
          "url": "http://www.securityfocus.com/archive/1/535142/100/0/threaded"
        },
        {
          "name": "73405",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/73405"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.coresecurity.com/advisories/schneider-vampset-stack-and-heap-buffer-overflow"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-092-01"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.schneider-electric.com/ww/en/download/document/SEVD-2015-084-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2014-8390",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a (1) CFG or (2) DAT file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20150330 [CORE-2015-0007] - Schneider Vampset Stack and Heap Buffer Overflow",
              "refsource": "BUGTRAQ",
              "url": "http://www.securityfocus.com/archive/1/535142/100/0/threaded"
            },
            {
              "name": "73405",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/73405"
            },
            {
              "name": "http://www.coresecurity.com/advisories/schneider-vampset-stack-and-heap-buffer-overflow",
              "refsource": "MISC",
              "url": "http://www.coresecurity.com/advisories/schneider-vampset-stack-and-heap-buffer-overflow"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-092-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-092-01"
            },
            {
              "name": "http://www.schneider-electric.com/ww/en/download/document/SEVD-2015-084-01",
              "refsource": "CONFIRM",
              "url": "http://www.schneider-electric.com/ww/en/download/document/SEVD-2015-084-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2014-8390",
    "datePublished": "2015-04-03T10:00:00",
    "dateReserved": "2014-10-22T00:00:00",
    "dateUpdated": "2024-08-06T13:18:48.295Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-5407 (GCVE-0-2014-5407)

Vulnerability from cvelistv5 – Published: 2014-09-15 14:00 – Updated: 2025-11-03 18:52
VLAI?
Summary
Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
Schneider Electric VAMPSET Affected: 0 , ≤ 2.2.136 (custom)
Unaffected: 2.2.145
Create a notification for this product.
Credits
Aivar Liimets of Martem AS
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T11:41:49.181Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-254-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "VAMPSET",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThanOrEqual": "2.2.136",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "2.2.145"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Aivar Liimets of Martem AS"
        }
      ],
      "datePublic": "2014-09-11T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMultiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.\u003c/p\u003e"
            }
          ],
          "value": "Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "MEDIUM",
            "accessVector": "LOCAL",
            "authentication": "SINGLE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.1,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:L/AC:M/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-03T18:52:21.206Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-254-01"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2014/icsa-14-254-01.json"
        },
        {
          "url": "http://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eSchneider Electric released an update for distribution on August 21, \n2014. The VAMPSET setting tool, v.2.2.145 or newer, can be found here:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/\"\u003ehttp://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/\u003c/a\u003e\u003c/p\u003eSchneider Electric recommends that all customers and users install and use VAMPSET v.2.2.145 or newer.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Schneider Electric released an update for distribution on August 21, \n2014. The VAMPSET setting tool, v.2.2.145 or newer, can be found here:\n\n\n http://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/ \n\nSchneider Electric recommends that all customers and users install and use VAMPSET v.2.2.145 or newer."
        }
      ],
      "source": {
        "advisory": "ICSA-14-254-01",
        "discovery": "EXTERNAL"
      },
      "title": "Schneider Electric VAMPSET Stack-based Buffer Overflow",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "To protect the computer and configuration files from unauthorized \nescalation of privileges through manipulation, Schneider Electric \nrecommends users employ best IT practices to secure their computers and \nrelay\u2019s configuration files and to use User Access Control (UAC) to \nfurther improve the security of the computer. Additionally, to minimize \nthe risk of attack, users who are not directly using this software on a \nregular basis are strongly encouraged to delete this application from \ntheir computer to reduce the likelihood of attack and to store relay \nconfiguration files in the client\u2019s protected location.\n\n\u003cbr\u003e"
            }
          ],
          "value": "To protect the computer and configuration files from unauthorized \nescalation of privileges through manipulation, Schneider Electric \nrecommends users employ best IT practices to secure their computers and \nrelay\u2019s configuration files and to use User Access Control (UAC) to \nfurther improve the security of the computer. Additionally, to minimize \nthe risk of attack, users who are not directly using this software on a \nregular basis are strongly encouraged to delete this application from \ntheir computer to reduce the likelihood of attack and to store relay \nconfiguration files in the client\u2019s protected location."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-5407",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-254-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-254-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-5407",
    "datePublished": "2014-09-15T14:00:00",
    "dateReserved": "2014-08-22T00:00:00",
    "dateUpdated": "2025-11-03T18:52:21.206Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2017-7967 (GCVE-0-2017-7967)

Vulnerability from nvd – Published: 2017-05-09 17:00 – Updated: 2024-08-05 16:19
VLAI?
Summary
All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corruption vulnerability when a corrupted vf2 file is used. This vulnerability causes the software to halt or not start when trying to open the corrupted file. This vulnerability occurs when fill settings are intentionally malformed and is opened in a standalone state, without connection to a protection relay. This attack is not considered to be remotely exploitable. This vulnerability has no effect on the operation of the protection relay to which VAMPSET is connected. As Windows operating system remains operational and VAMPSET responds, it is able to be shut down through its normal closing protocol.
Severity ?
No CVSS data available.
CWE
  • Memory Corruption
Assigner
References
Impacted products
Vendor Product Version
Schneider Electric SE VAMPSET Affected: All versions prior to 2.2.189
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:19:29.398Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "97124",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/97124"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-061-01/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VAMPSET",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to 2.2.189"
            }
          ]
        }
      ],
      "datePublic": "2017-03-02T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corruption vulnerability when a corrupted vf2 file is used. This vulnerability causes the software to halt or not start when trying to open the corrupted file. This vulnerability occurs when fill settings are intentionally malformed and is opened in a standalone state, without connection to a protection relay. This attack is not considered to be remotely exploitable. This vulnerability has no effect on the operation of the protection relay to which VAMPSET is connected. As Windows operating system remains operational and VAMPSET responds, it is able to be shut down through its normal closing protocol."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Memory Corruption",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-05-22T09:57:01",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "name": "97124",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/97124"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-061-01/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2017-7967",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VAMPSET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions prior to 2.2.189"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corruption vulnerability when a corrupted vf2 file is used. This vulnerability causes the software to halt or not start when trying to open the corrupted file. This vulnerability occurs when fill settings are intentionally malformed and is opened in a standalone state, without connection to a protection relay. This attack is not considered to be remotely exploitable. This vulnerability has no effect on the operation of the protection relay to which VAMPSET is connected. As Windows operating system remains operational and VAMPSET responds, it is able to be shut down through its normal closing protocol."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Memory Corruption"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "97124",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/97124"
            },
            {
              "name": "http://www.schneider-electric.com/en/download/document/SEVD-2017-061-01/",
              "refsource": "CONFIRM",
              "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-061-01/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2017-7967",
    "datePublished": "2017-05-09T17:00:00",
    "dateReserved": "2017-04-19T00:00:00",
    "dateUpdated": "2024-08-05T16:19:29.398Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-8390 (GCVE-0-2014-8390)

Vulnerability from nvd – Published: 2015-04-03 10:00 – Updated: 2024-08-06 13:18
VLAI?
Summary
Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a (1) CFG or (2) DAT file.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:18:48.295Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20150330 [CORE-2015-0007] - Schneider Vampset Stack and Heap Buffer Overflow",
            "tags": [
              "mailing-list",
              "x_refsource_BUGTRAQ",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/archive/1/535142/100/0/threaded"
          },
          {
            "name": "73405",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/73405"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.coresecurity.com/advisories/schneider-vampset-stack-and-heap-buffer-overflow"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-092-01"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.schneider-electric.com/ww/en/download/document/SEVD-2015-084-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2015-04-02T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a (1) CFG or (2) DAT file."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-09T18:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "20150330 [CORE-2015-0007] - Schneider Vampset Stack and Heap Buffer Overflow",
          "tags": [
            "mailing-list",
            "x_refsource_BUGTRAQ"
          ],
          "url": "http://www.securityfocus.com/archive/1/535142/100/0/threaded"
        },
        {
          "name": "73405",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/73405"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.coresecurity.com/advisories/schneider-vampset-stack-and-heap-buffer-overflow"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-092-01"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.schneider-electric.com/ww/en/download/document/SEVD-2015-084-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2014-8390",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a (1) CFG or (2) DAT file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20150330 [CORE-2015-0007] - Schneider Vampset Stack and Heap Buffer Overflow",
              "refsource": "BUGTRAQ",
              "url": "http://www.securityfocus.com/archive/1/535142/100/0/threaded"
            },
            {
              "name": "73405",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/73405"
            },
            {
              "name": "http://www.coresecurity.com/advisories/schneider-vampset-stack-and-heap-buffer-overflow",
              "refsource": "MISC",
              "url": "http://www.coresecurity.com/advisories/schneider-vampset-stack-and-heap-buffer-overflow"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-092-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-092-01"
            },
            {
              "name": "http://www.schneider-electric.com/ww/en/download/document/SEVD-2015-084-01",
              "refsource": "CONFIRM",
              "url": "http://www.schneider-electric.com/ww/en/download/document/SEVD-2015-084-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2014-8390",
    "datePublished": "2015-04-03T10:00:00",
    "dateReserved": "2014-10-22T00:00:00",
    "dateUpdated": "2024-08-06T13:18:48.295Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-5407 (GCVE-0-2014-5407)

Vulnerability from nvd – Published: 2014-09-15 14:00 – Updated: 2025-11-03 18:52
VLAI?
Summary
Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
Schneider Electric VAMPSET Affected: 0 , ≤ 2.2.136 (custom)
Unaffected: 2.2.145
Create a notification for this product.
Credits
Aivar Liimets of Martem AS
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T11:41:49.181Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-254-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "VAMPSET",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThanOrEqual": "2.2.136",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "2.2.145"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Aivar Liimets of Martem AS"
        }
      ],
      "datePublic": "2014-09-11T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMultiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.\u003c/p\u003e"
            }
          ],
          "value": "Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "MEDIUM",
            "accessVector": "LOCAL",
            "authentication": "SINGLE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.1,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:L/AC:M/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-03T18:52:21.206Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-254-01"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2014/icsa-14-254-01.json"
        },
        {
          "url": "http://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eSchneider Electric released an update for distribution on August 21, \n2014. The VAMPSET setting tool, v.2.2.145 or newer, can be found here:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/\"\u003ehttp://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/\u003c/a\u003e\u003c/p\u003eSchneider Electric recommends that all customers and users install and use VAMPSET v.2.2.145 or newer.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Schneider Electric released an update for distribution on August 21, \n2014. The VAMPSET setting tool, v.2.2.145 or newer, can be found here:\n\n\n http://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/ \n\nSchneider Electric recommends that all customers and users install and use VAMPSET v.2.2.145 or newer."
        }
      ],
      "source": {
        "advisory": "ICSA-14-254-01",
        "discovery": "EXTERNAL"
      },
      "title": "Schneider Electric VAMPSET Stack-based Buffer Overflow",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "To protect the computer and configuration files from unauthorized \nescalation of privileges through manipulation, Schneider Electric \nrecommends users employ best IT practices to secure their computers and \nrelay\u2019s configuration files and to use User Access Control (UAC) to \nfurther improve the security of the computer. Additionally, to minimize \nthe risk of attack, users who are not directly using this software on a \nregular basis are strongly encouraged to delete this application from \ntheir computer to reduce the likelihood of attack and to store relay \nconfiguration files in the client\u2019s protected location.\n\n\u003cbr\u003e"
            }
          ],
          "value": "To protect the computer and configuration files from unauthorized \nescalation of privileges through manipulation, Schneider Electric \nrecommends users employ best IT practices to secure their computers and \nrelay\u2019s configuration files and to use User Access Control (UAC) to \nfurther improve the security of the computer. Additionally, to minimize \nthe risk of attack, users who are not directly using this software on a \nregular basis are strongly encouraged to delete this application from \ntheir computer to reduce the likelihood of attack and to store relay \nconfiguration files in the client\u2019s protected location."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-5407",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-254-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-254-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-5407",
    "datePublished": "2014-09-15T14:00:00",
    "dateReserved": "2014-08-22T00:00:00",
    "dateUpdated": "2025-11-03T18:52:21.206Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}