Search criteria
21 vulnerabilities found for vigorconnect by draytek
FKIE_CVE-2021-20124
Vulnerability from fkie_nvd - Published: 2021-10-13 16:15 - Updated: 2025-11-03 18:59
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Summary
A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges.
References
| URL | Tags | ||
|---|---|---|---|
| vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory | |
| 134c704f-9b21-4f2e-91b3-4a467353bcc0 | https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20124 | US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| draytek | vigorconnect | 1.6.0 |
{
"cisaActionDue": "2024-09-24",
"cisaExploitAdd": "2024-09-03",
"cisaRequiredAction": "Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.",
"cisaVulnerabilityName": "Draytek VigorConnect Path Traversal Vulnerability ",
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*",
"matchCriteriaId": "CC518B3A-EDB0-434A-8CF5-026437FF5A13",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad de inclusi\u00f3n de archivos locales en Draytek VigorConnect versi\u00f3n 1.6.0-B3, en la funcionalidad file download del endpoint WebServlet. Un atacante no autenticado podr\u00eda aprovechar esta vulnerabilidad para descargar archivos arbitrarios desde el sistema operativo subyacente con privilegios de root"
}
],
"id": "CVE-2021-20124",
"lastModified": "2025-11-03T18:59:02.260",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 7.8,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2021-10-13T16:15:07.397",
"references": [
{
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"tags": [
"US Government Resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20124"
}
],
"sourceIdentifier": "vulnreport@tenable.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2021-20125
Vulnerability from fkie_nvd - Published: 2021-10-13 16:15 - Updated: 2024-11-21 05:45
Severity ?
Summary
An arbitrary file upload and directory traversal vulnerability exists in the file upload functionality of DownloadFileServlet in Draytek VigorConnect 1.6.0-B3. An unauthenticated attacker could leverage this vulnerability to upload files to any location on the target operating system with root privileges.
References
| URL | Tags | ||
|---|---|---|---|
| vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| draytek | vigorconnect | 1.6.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*",
"matchCriteriaId": "CC518B3A-EDB0-434A-8CF5-026437FF5A13",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An arbitrary file upload and directory traversal vulnerability exists in the file upload functionality of DownloadFileServlet in Draytek VigorConnect 1.6.0-B3. An unauthenticated attacker could leverage this vulnerability to upload files to any location on the target operating system with root privileges."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad de carga arbitraria de archivos y de salto de directorio en la funcionalidad upload functionality de DownloadFileServlet en Draytek VigorConnect versi\u00f3n 1.6.0-B3. Un atacante no autenticado podr\u00eda aprovechar esta vulnerabilidad para subir archivos a cualquier ubicaci\u00f3n en el sistema operativo de destino con privilegios de root"
}
],
"id": "CVE-2021-20125",
"lastModified": "2024-11-21T05:45:58.373",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-10-13T16:15:07.437",
"references": [
{
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"sourceIdentifier": "vulnreport@tenable.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
},
{
"lang": "en",
"value": "CWE-434"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-20127
Vulnerability from fkie_nvd - Published: 2021-10-13 16:15 - Updated: 2024-11-21 05:45
Severity ?
Summary
An arbitrary file deletion vulnerability exists in the file delete functionality of the Html5Servlet endpoint of Draytek VigorConnect 1.6.0-B3. This allows an authenticated user to arbitrarily delete files in any location on the target operating system with root privileges.
References
| URL | Tags | ||
|---|---|---|---|
| vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| draytek | vigorconnect | 1.6.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*",
"matchCriteriaId": "CC518B3A-EDB0-434A-8CF5-026437FF5A13",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An arbitrary file deletion vulnerability exists in the file delete functionality of the Html5Servlet endpoint of Draytek VigorConnect 1.6.0-B3. This allows an authenticated user to arbitrarily delete files in any location on the target operating system with root privileges."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad de eliminaci\u00f3n arbitraria de archivos en la funcionalidad file delete del endpoint Html5Servlet de Draytek VigorConnect versi\u00f3n 1.6.0-B3. Esto permite a un usuario autenticado eliminar arbitrariamente archivos en cualquier ubicaci\u00f3n del sistema operativo de destino con privilegios de root"
}
],
"id": "CVE-2021-20127",
"lastModified": "2024-11-21T05:45:58.587",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 8.5,
"confidentialityImpact": "NONE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 9.2,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-10-13T16:15:07.517",
"references": [
{
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"sourceIdentifier": "vulnreport@tenable.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-20128
Vulnerability from fkie_nvd - Published: 2021-10-13 16:15 - Updated: 2024-11-21 05:45
Severity ?
Summary
The Profile Name field in the floor plan (Network Menu) page in Draytek VigorConnect 1.6.0-B3 was found to be vulnerable to stored XSS, as user input is not properly sanitized.
References
| URL | Tags | ||
|---|---|---|---|
| vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| draytek | vigorconnect | 1.6.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*",
"matchCriteriaId": "CC518B3A-EDB0-434A-8CF5-026437FF5A13",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The Profile Name field in the floor plan (Network Menu) page in Draytek VigorConnect 1.6.0-B3 was found to be vulnerable to stored XSS, as user input is not properly sanitized."
},
{
"lang": "es",
"value": "El campo Profile Name en la p\u00e1gina floor plan (Network Menu) en Draytek VigorConnect versi\u00f3n 1.6.0-B3 se ha encontrado que es vulnerable a un ataque de tipo XSS almacenado, ya que la entrada del usuario no est\u00e1 saneada apropiadamente"
}
],
"id": "CVE-2021-20128",
"lastModified": "2024-11-21T05:45:58.697",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.3,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-10-13T16:15:07.557",
"references": [
{
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"sourceIdentifier": "vulnreport@tenable.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-20129
Vulnerability from fkie_nvd - Published: 2021-10-13 16:15 - Updated: 2024-11-21 05:45
Severity ?
Summary
An information disclosure vulnerability exists in Draytek VigorConnect 1.6.0-B3, allowing an unauthenticated attacker to export system logs.
References
| URL | Tags | ||
|---|---|---|---|
| vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| draytek | vigorconnect | 1.6.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*",
"matchCriteriaId": "CC518B3A-EDB0-434A-8CF5-026437FF5A13",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An information disclosure vulnerability exists in Draytek VigorConnect 1.6.0-B3, allowing an unauthenticated attacker to export system logs."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n en Draytek VigorConnect versi\u00f3n 1.6.0-B3, que permite a un atacante no autenticado exportar los registros del sistema"
}
],
"id": "CVE-2021-20129",
"lastModified": "2024-11-21T05:45:58.793",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-10-13T16:15:07.600",
"references": [
{
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"sourceIdentifier": "vulnreport@tenable.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-532"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-20123
Vulnerability from fkie_nvd - Published: 2021-10-13 16:15 - Updated: 2025-11-03 18:59
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Summary
A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges.
References
| URL | Tags | ||
|---|---|---|---|
| vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory | |
| 134c704f-9b21-4f2e-91b3-4a467353bcc0 | https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20123 | US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| draytek | vigorconnect | 1.6.0 |
{
"cisaActionDue": "2024-09-24",
"cisaExploitAdd": "2024-09-03",
"cisaRequiredAction": "Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.",
"cisaVulnerabilityName": "Draytek VigorConnect Path Traversal Vulnerability ",
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*",
"matchCriteriaId": "CC518B3A-EDB0-434A-8CF5-026437FF5A13",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad de inclusi\u00f3n de archivos locales en Draytek VigorConnect versi\u00f3n 1.6.0-B3, en la funcionalidad file download del endpoint DownloadFileServlet. Un atacante no autenticado podr\u00eda aprovechar esta vulnerabilidad para descargar archivos arbitrarios del sistema operativo subyacente con privilegios de root"
}
],
"id": "CVE-2021-20123",
"lastModified": "2025-11-03T18:59:21.040",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 7.8,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2021-10-13T16:15:07.350",
"references": [
{
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"tags": [
"US Government Resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20123"
}
],
"sourceIdentifier": "vulnreport@tenable.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2021-20126
Vulnerability from fkie_nvd - Published: 2021-10-13 16:15 - Updated: 2024-11-21 05:45
Severity ?
Summary
Draytek VigorConnect 1.6.0-B3 lacks cross-site request forgery protections and does not sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.
References
| URL | Tags | ||
|---|---|---|---|
| vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| draytek | vigorconnect | 1.6.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*",
"matchCriteriaId": "CC518B3A-EDB0-434A-8CF5-026437FF5A13",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Draytek VigorConnect 1.6.0-B3 lacks cross-site request forgery protections and does not sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request."
},
{
"lang": "es",
"value": "Draytek VigorConnect versi\u00f3n 1.6.0-B3, carece de protecciones contra vulnerabilidades de tipo cross-site request forgery y no comprueba suficientemente si una petici\u00f3n bien formada, v\u00e1lida y consistente fue proporcionada intencionadamente por el usuario que envi\u00f3 la petici\u00f3n"
}
],
"id": "CVE-2021-20126",
"lastModified": "2024-11-21T05:45:58.490",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-10-13T16:15:07.477",
"references": [
{
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"sourceIdentifier": "vulnreport@tenable.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-352"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2021-20129 (GCVE-0-2021-20129)
Vulnerability from cvelistv5 – Published: 2021-10-13 15:49 – Updated: 2024-08-03 17:30
VLAI?
Summary
An information disclosure vulnerability exists in Draytek VigorConnect 1.6.0-B3, allowing an unauthenticated attacker to export system logs.
Severity ?
No CVSS data available.
CWE
- Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Draytek VigorConnect |
Affected:
1.6.0-B3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:30:07.422Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Draytek VigorConnect",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "1.6.0-B3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An information disclosure vulnerability exists in Draytek VigorConnect 1.6.0-B3, allowing an unauthenticated attacker to export system logs."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-13T15:49:35",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2021-20129",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Draytek VigorConnect",
"version": {
"version_data": [
{
"version_value": "1.6.0-B3"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An information disclosure vulnerability exists in Draytek VigorConnect 1.6.0-B3, allowing an unauthenticated attacker to export system logs."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Exposure of Sensitive Information to an Unauthorized Actor"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2021-42",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2021-20129",
"datePublished": "2021-10-13T15:49:35",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:30:07.422Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20128 (GCVE-0-2021-20128)
Vulnerability from cvelistv5 – Published: 2021-10-13 15:49 – Updated: 2024-08-03 17:30
VLAI?
Summary
The Profile Name field in the floor plan (Network Menu) page in Draytek VigorConnect 1.6.0-B3 was found to be vulnerable to stored XSS, as user input is not properly sanitized.
Severity ?
No CVSS data available.
CWE
- Cross-site Scripting
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Draytek VigorConnect |
Affected:
1.6.0-B3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:30:07.492Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Draytek VigorConnect",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "1.6.0-B3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Profile Name field in the floor plan (Network Menu) page in Draytek VigorConnect 1.6.0-B3 was found to be vulnerable to stored XSS, as user input is not properly sanitized."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Cross-site Scripting",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-13T15:49:30",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2021-20128",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Draytek VigorConnect",
"version": {
"version_data": [
{
"version_value": "1.6.0-B3"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Profile Name field in the floor plan (Network Menu) page in Draytek VigorConnect 1.6.0-B3 was found to be vulnerable to stored XSS, as user input is not properly sanitized."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Cross-site Scripting"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2021-42",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2021-20128",
"datePublished": "2021-10-13T15:49:30",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:30:07.492Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20127 (GCVE-0-2021-20127)
Vulnerability from cvelistv5 – Published: 2021-10-13 15:49 – Updated: 2024-08-03 17:30
VLAI?
Summary
An arbitrary file deletion vulnerability exists in the file delete functionality of the Html5Servlet endpoint of Draytek VigorConnect 1.6.0-B3. This allows an authenticated user to arbitrarily delete files in any location on the target operating system with root privileges.
Severity ?
No CVSS data available.
CWE
- Improper Access Control
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Draytek VigorConnect |
Affected:
1.6.0-B3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:30:07.367Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Draytek VigorConnect",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "1.6.0-B3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An arbitrary file deletion vulnerability exists in the file delete functionality of the Html5Servlet endpoint of Draytek VigorConnect 1.6.0-B3. This allows an authenticated user to arbitrarily delete files in any location on the target operating system with root privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Improper Access Control",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-13T15:49:25",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2021-20127",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Draytek VigorConnect",
"version": {
"version_data": [
{
"version_value": "1.6.0-B3"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An arbitrary file deletion vulnerability exists in the file delete functionality of the Html5Servlet endpoint of Draytek VigorConnect 1.6.0-B3. This allows an authenticated user to arbitrarily delete files in any location on the target operating system with root privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2021-42",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2021-20127",
"datePublished": "2021-10-13T15:49:25",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:30:07.367Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20126 (GCVE-0-2021-20126)
Vulnerability from cvelistv5 – Published: 2021-10-13 15:48 – Updated: 2024-08-03 17:30
VLAI?
Summary
Draytek VigorConnect 1.6.0-B3 lacks cross-site request forgery protections and does not sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.
Severity ?
No CVSS data available.
CWE
- Cross-Site Request Forgery
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Draytek VigorConnect |
Affected:
1.6.0-B3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:30:07.598Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Draytek VigorConnect",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "1.6.0-B3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Draytek VigorConnect 1.6.0-B3 lacks cross-site request forgery protections and does not sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Cross-Site Request Forgery",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-13T15:48:15",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2021-20126",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Draytek VigorConnect",
"version": {
"version_data": [
{
"version_value": "1.6.0-B3"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Draytek VigorConnect 1.6.0-B3 lacks cross-site request forgery protections and does not sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Cross-Site Request Forgery"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2021-42",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2021-20126",
"datePublished": "2021-10-13T15:48:15",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:30:07.598Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20125 (GCVE-0-2021-20125)
Vulnerability from cvelistv5 – Published: 2021-10-13 15:48 – Updated: 2024-08-03 17:30
VLAI?
Summary
An arbitrary file upload and directory traversal vulnerability exists in the file upload functionality of DownloadFileServlet in Draytek VigorConnect 1.6.0-B3. An unauthenticated attacker could leverage this vulnerability to upload files to any location on the target operating system with root privileges.
Severity ?
No CVSS data available.
CWE
- Unrestricted Upload of File with Dangerous Type
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Draytek VigorConnect |
Affected:
1.6.0-B3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:30:07.504Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Draytek VigorConnect",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "1.6.0-B3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An arbitrary file upload and directory traversal vulnerability exists in the file upload functionality of DownloadFileServlet in Draytek VigorConnect 1.6.0-B3. An unauthenticated attacker could leverage this vulnerability to upload files to any location on the target operating system with root privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Unrestricted Upload of File with Dangerous Type",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-13T15:48:08",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2021-20125",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Draytek VigorConnect",
"version": {
"version_data": [
{
"version_value": "1.6.0-B3"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An arbitrary file upload and directory traversal vulnerability exists in the file upload functionality of DownloadFileServlet in Draytek VigorConnect 1.6.0-B3. An unauthenticated attacker could leverage this vulnerability to upload files to any location on the target operating system with root privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Unrestricted Upload of File with Dangerous Type"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2021-42",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2021-20125",
"datePublished": "2021-10-13T15:48:08",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:30:07.504Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20124 (GCVE-0-2021-20124)
Vulnerability from cvelistv5 – Published: 2021-10-13 15:48 – Updated: 2025-10-21 23:25
VLAI?
Summary
A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges.
Severity ?
7.5 (High)
CWE
- Path Traversal
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Draytek VigorConnect |
Affected:
1.6.0-B3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:30:07.526Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "vigorconnect",
"vendor": "draytek",
"versions": [
{
"status": "affected",
"version": "1.6.0"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2021-20124",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-03T12:28:51.460379Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2024-09-03",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20124"
},
"type": "kev"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T23:25:28.553Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20124"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-09-03T00:00:00+00:00",
"value": "CVE-2021-20124 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Draytek VigorConnect",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "1.6.0-B3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Path Traversal",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-13T15:48:03.000Z",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2021-20124",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Draytek VigorConnect",
"version": {
"version_data": [
{
"version_value": "1.6.0-B3"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Path Traversal"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2021-42",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2021-20124",
"datePublished": "2021-10-13T15:48:03.000Z",
"dateReserved": "2020-12-17T00:00:00.000Z",
"dateUpdated": "2025-10-21T23:25:28.553Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20123 (GCVE-0-2021-20123)
Vulnerability from cvelistv5 – Published: 2021-10-13 15:47 – Updated: 2025-10-21 23:25
VLAI?
Summary
A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges.
Severity ?
7.5 (High)
CWE
- Path Traversal
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Draytek VigorConnect |
Affected:
1.6.0-B3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:30:07.620Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "vigorconnect",
"vendor": "draytek",
"versions": [
{
"status": "affected",
"version": "1.6.0"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2021-20123",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-03T12:29:01.834786Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2024-09-03",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20123"
},
"type": "kev"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T23:25:28.693Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20123"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-09-03T00:00:00+00:00",
"value": "CVE-2021-20123 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Draytek VigorConnect",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "1.6.0-B3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Path Traversal",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-13T15:47:58.000Z",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2021-20123",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Draytek VigorConnect",
"version": {
"version_data": [
{
"version_value": "1.6.0-B3"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Path Traversal"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2021-42",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2021-20123",
"datePublished": "2021-10-13T15:47:58.000Z",
"dateReserved": "2020-12-17T00:00:00.000Z",
"dateUpdated": "2025-10-21T23:25:28.693Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20129 (GCVE-0-2021-20129)
Vulnerability from nvd – Published: 2021-10-13 15:49 – Updated: 2024-08-03 17:30
VLAI?
Summary
An information disclosure vulnerability exists in Draytek VigorConnect 1.6.0-B3, allowing an unauthenticated attacker to export system logs.
Severity ?
No CVSS data available.
CWE
- Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Draytek VigorConnect |
Affected:
1.6.0-B3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:30:07.422Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Draytek VigorConnect",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "1.6.0-B3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An information disclosure vulnerability exists in Draytek VigorConnect 1.6.0-B3, allowing an unauthenticated attacker to export system logs."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-13T15:49:35",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2021-20129",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Draytek VigorConnect",
"version": {
"version_data": [
{
"version_value": "1.6.0-B3"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An information disclosure vulnerability exists in Draytek VigorConnect 1.6.0-B3, allowing an unauthenticated attacker to export system logs."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Exposure of Sensitive Information to an Unauthorized Actor"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2021-42",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2021-20129",
"datePublished": "2021-10-13T15:49:35",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:30:07.422Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20128 (GCVE-0-2021-20128)
Vulnerability from nvd – Published: 2021-10-13 15:49 – Updated: 2024-08-03 17:30
VLAI?
Summary
The Profile Name field in the floor plan (Network Menu) page in Draytek VigorConnect 1.6.0-B3 was found to be vulnerable to stored XSS, as user input is not properly sanitized.
Severity ?
No CVSS data available.
CWE
- Cross-site Scripting
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Draytek VigorConnect |
Affected:
1.6.0-B3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:30:07.492Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Draytek VigorConnect",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "1.6.0-B3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Profile Name field in the floor plan (Network Menu) page in Draytek VigorConnect 1.6.0-B3 was found to be vulnerable to stored XSS, as user input is not properly sanitized."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Cross-site Scripting",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-13T15:49:30",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2021-20128",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Draytek VigorConnect",
"version": {
"version_data": [
{
"version_value": "1.6.0-B3"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Profile Name field in the floor plan (Network Menu) page in Draytek VigorConnect 1.6.0-B3 was found to be vulnerable to stored XSS, as user input is not properly sanitized."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Cross-site Scripting"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2021-42",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2021-20128",
"datePublished": "2021-10-13T15:49:30",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:30:07.492Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20127 (GCVE-0-2021-20127)
Vulnerability from nvd – Published: 2021-10-13 15:49 – Updated: 2024-08-03 17:30
VLAI?
Summary
An arbitrary file deletion vulnerability exists in the file delete functionality of the Html5Servlet endpoint of Draytek VigorConnect 1.6.0-B3. This allows an authenticated user to arbitrarily delete files in any location on the target operating system with root privileges.
Severity ?
No CVSS data available.
CWE
- Improper Access Control
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Draytek VigorConnect |
Affected:
1.6.0-B3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:30:07.367Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Draytek VigorConnect",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "1.6.0-B3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An arbitrary file deletion vulnerability exists in the file delete functionality of the Html5Servlet endpoint of Draytek VigorConnect 1.6.0-B3. This allows an authenticated user to arbitrarily delete files in any location on the target operating system with root privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Improper Access Control",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-13T15:49:25",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2021-20127",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Draytek VigorConnect",
"version": {
"version_data": [
{
"version_value": "1.6.0-B3"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An arbitrary file deletion vulnerability exists in the file delete functionality of the Html5Servlet endpoint of Draytek VigorConnect 1.6.0-B3. This allows an authenticated user to arbitrarily delete files in any location on the target operating system with root privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2021-42",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2021-20127",
"datePublished": "2021-10-13T15:49:25",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:30:07.367Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20126 (GCVE-0-2021-20126)
Vulnerability from nvd – Published: 2021-10-13 15:48 – Updated: 2024-08-03 17:30
VLAI?
Summary
Draytek VigorConnect 1.6.0-B3 lacks cross-site request forgery protections and does not sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.
Severity ?
No CVSS data available.
CWE
- Cross-Site Request Forgery
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Draytek VigorConnect |
Affected:
1.6.0-B3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:30:07.598Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Draytek VigorConnect",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "1.6.0-B3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Draytek VigorConnect 1.6.0-B3 lacks cross-site request forgery protections and does not sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Cross-Site Request Forgery",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-13T15:48:15",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2021-20126",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Draytek VigorConnect",
"version": {
"version_data": [
{
"version_value": "1.6.0-B3"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Draytek VigorConnect 1.6.0-B3 lacks cross-site request forgery protections and does not sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Cross-Site Request Forgery"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2021-42",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2021-20126",
"datePublished": "2021-10-13T15:48:15",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:30:07.598Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20125 (GCVE-0-2021-20125)
Vulnerability from nvd – Published: 2021-10-13 15:48 – Updated: 2024-08-03 17:30
VLAI?
Summary
An arbitrary file upload and directory traversal vulnerability exists in the file upload functionality of DownloadFileServlet in Draytek VigorConnect 1.6.0-B3. An unauthenticated attacker could leverage this vulnerability to upload files to any location on the target operating system with root privileges.
Severity ?
No CVSS data available.
CWE
- Unrestricted Upload of File with Dangerous Type
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Draytek VigorConnect |
Affected:
1.6.0-B3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:30:07.504Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Draytek VigorConnect",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "1.6.0-B3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An arbitrary file upload and directory traversal vulnerability exists in the file upload functionality of DownloadFileServlet in Draytek VigorConnect 1.6.0-B3. An unauthenticated attacker could leverage this vulnerability to upload files to any location on the target operating system with root privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Unrestricted Upload of File with Dangerous Type",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-13T15:48:08",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2021-20125",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Draytek VigorConnect",
"version": {
"version_data": [
{
"version_value": "1.6.0-B3"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An arbitrary file upload and directory traversal vulnerability exists in the file upload functionality of DownloadFileServlet in Draytek VigorConnect 1.6.0-B3. An unauthenticated attacker could leverage this vulnerability to upload files to any location on the target operating system with root privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Unrestricted Upload of File with Dangerous Type"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2021-42",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2021-20125",
"datePublished": "2021-10-13T15:48:08",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:30:07.504Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20124 (GCVE-0-2021-20124)
Vulnerability from nvd – Published: 2021-10-13 15:48 – Updated: 2025-10-21 23:25
VLAI?
Summary
A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges.
Severity ?
7.5 (High)
CWE
- Path Traversal
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Draytek VigorConnect |
Affected:
1.6.0-B3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:30:07.526Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "vigorconnect",
"vendor": "draytek",
"versions": [
{
"status": "affected",
"version": "1.6.0"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2021-20124",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-03T12:28:51.460379Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2024-09-03",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20124"
},
"type": "kev"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T23:25:28.553Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20124"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-09-03T00:00:00+00:00",
"value": "CVE-2021-20124 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Draytek VigorConnect",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "1.6.0-B3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Path Traversal",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-13T15:48:03.000Z",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2021-20124",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Draytek VigorConnect",
"version": {
"version_data": [
{
"version_value": "1.6.0-B3"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Path Traversal"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2021-42",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2021-20124",
"datePublished": "2021-10-13T15:48:03.000Z",
"dateReserved": "2020-12-17T00:00:00.000Z",
"dateUpdated": "2025-10-21T23:25:28.553Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20123 (GCVE-0-2021-20123)
Vulnerability from nvd – Published: 2021-10-13 15:47 – Updated: 2025-10-21 23:25
VLAI?
Summary
A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges.
Severity ?
7.5 (High)
CWE
- Path Traversal
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Draytek VigorConnect |
Affected:
1.6.0-B3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:30:07.620Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "vigorconnect",
"vendor": "draytek",
"versions": [
{
"status": "affected",
"version": "1.6.0"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2021-20123",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-03T12:29:01.834786Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2024-09-03",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20123"
},
"type": "kev"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T23:25:28.693Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20123"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-09-03T00:00:00+00:00",
"value": "CVE-2021-20123 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Draytek VigorConnect",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "1.6.0-B3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Path Traversal",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-13T15:47:58.000Z",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2021-20123",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Draytek VigorConnect",
"version": {
"version_data": [
{
"version_value": "1.6.0-B3"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Path Traversal"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2021-42",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-42"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2021-20123",
"datePublished": "2021-10-13T15:47:58.000Z",
"dateReserved": "2020-12-17T00:00:00.000Z",
"dateUpdated": "2025-10-21T23:25:28.693Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}