Search criteria
12 vulnerabilities found for w6 by tenda
VAR-202401-1159
Vulnerability from variot - Updated: 2024-05-17 23:03A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been declared as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252259. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of w6 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202401-1159",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w6",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.9\\(4122\\)"
},
{
"model": "w6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w6 firmware 1.0.0.9(4122)"
},
{
"model": "w6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-001959"
},
{
"db": "NVD",
"id": "CVE-2024-0994"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:w6_firmware:1.0.0.9\\(4122\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:w6:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2024-0994"
}
]
},
"cve": "CVE-2024-0994",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "MULTIPLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.4,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2024-0994",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2024-0994",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "cna@vuldb.com",
"id": "CVE-2024-0994",
"trust": 1.0,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-001959"
},
{
"db": "NVD",
"id": "CVE-2024-0994"
},
{
"db": "NVD",
"id": "CVE-2024-0994"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been declared as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252259. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of w6 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-0994"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-001959"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-0994",
"trust": 2.6
},
{
"db": "VULDB",
"id": "252259",
"trust": 1.0
},
{
"db": "JVNDB",
"id": "JVNDB-2024-001959",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-001959"
},
{
"db": "NVD",
"id": "CVE-2024-0994"
}
]
},
"id": "VAR-202401-1159",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.6666667
},
"last_update_date": "2024-05-17T23:03:50.405000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-001959"
},
{
"db": "NVD",
"id": "CVE-2024-0994"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.0,
"url": "https://jylsec.notion.site/tenda-w6-has-stack-buffer-overflow-vulnerability-in-formsetcfm-4fab28f92ca74f519245b606d8345821?pvs=4"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.252259"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?id.252259"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-0994"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-001959"
},
{
"db": "NVD",
"id": "CVE-2024-0994"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2024-001959"
},
{
"db": "NVD",
"id": "CVE-2024-0994"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-02-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-001959"
},
{
"date": "2024-01-29T02:15:07.940000",
"db": "NVD",
"id": "CVE-2024-0994"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-02-07T03:06:00",
"db": "JVNDB",
"id": "JVNDB-2024-001959"
},
{
"date": "2024-05-17T02:35:08.063000",
"db": "NVD",
"id": "CVE-2024-0994"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w6\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-001959"
}
],
"trust": 0.8
}
}
VAR-202401-1126
Vulnerability from variot - Updated: 2024-05-17 22:57A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been rated as critical. Affected by this issue is the function formwrlSSIDset of the file /goform/wifiSSIDset of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252260. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of w6 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202401-1126",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w6",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.9\\(4122\\)"
},
{
"model": "w6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w6 firmware 1.0.0.9(4122)"
},
{
"model": "w6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-001958"
},
{
"db": "NVD",
"id": "CVE-2024-0995"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:w6_firmware:1.0.0.9\\(4122\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:w6:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2024-0995"
}
]
},
"cve": "CVE-2024-0995",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "MULTIPLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.4,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2024-0995",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2024-0995",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "cna@vuldb.com",
"id": "CVE-2024-0995",
"trust": 1.0,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-001958"
},
{
"db": "NVD",
"id": "CVE-2024-0995"
},
{
"db": "NVD",
"id": "CVE-2024-0995"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been rated as critical. Affected by this issue is the function formwrlSSIDset of the file /goform/wifiSSIDset of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252260. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of w6 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-0995"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-001958"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-0995",
"trust": 2.6
},
{
"db": "VULDB",
"id": "252260",
"trust": 1.0
},
{
"db": "JVNDB",
"id": "JVNDB-2024-001958",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-001958"
},
{
"db": "NVD",
"id": "CVE-2024-0995"
}
]
},
"id": "VAR-202401-1126",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.6666667
},
"last_update_date": "2024-05-17T22:57:33.313000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-001958"
},
{
"db": "NVD",
"id": "CVE-2024-0995"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.0,
"url": "https://jylsec.notion.site/tenda-w6-has-stack-buffer-overflow-vulnerability-in-formwrlssidset-e283b41905934e97b4c65632a0018eba?pvs=4"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.252260"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?id.252260"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-0995"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-001958"
},
{
"db": "NVD",
"id": "CVE-2024-0995"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2024-001958"
},
{
"db": "NVD",
"id": "CVE-2024-0995"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-02-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-001958"
},
{
"date": "2024-01-29T02:15:08.190000",
"db": "NVD",
"id": "CVE-2024-0995"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-02-07T03:06:00",
"db": "JVNDB",
"id": "JVNDB-2024-001958"
},
{
"date": "2024-05-17T02:35:08.170000",
"db": "NVD",
"id": "CVE-2024-0995"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w6\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-001958"
}
],
"trust": 0.8
}
}
VAR-202208-0978
Vulnerability from variot - Updated: 2023-12-18 14:03A stack overflow vulnerability exists in /goform/WifiMacFilterGet in Tenda W6 V1.0.0.9(4122) version, which can be exploited by attackers to cause a denial of service (DoS) via the index parameter. Shenzhen Tenda Technology Co.,Ltd. of w6 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda W6 is a wireless WiFi AP access point router from China Tenda Company
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202208-0978",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w6",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.9\\(4122\\)"
},
{
"model": "w6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w6 firmware 1.0.0.9(4122)"
},
{
"model": "w6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w6",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0.0.9(4122)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75789"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014754"
},
{
"db": "NVD",
"id": "CVE-2022-35558"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:w6_firmware:1.0.0.9\\(4122\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:w6:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-35558"
}
]
},
"cve": "CVE-2022-35558",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-75789",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-35558",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-35558",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2022-75789",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202208-2837",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75789"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014754"
},
{
"db": "NVD",
"id": "CVE-2022-35558"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2837"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A stack overflow vulnerability exists in /goform/WifiMacFilterGet in Tenda W6 V1.0.0.9(4122) version, which can be exploited by attackers to cause a denial of service (DoS) via the index parameter. Shenzhen Tenda Technology Co.,Ltd. of w6 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda W6 is a wireless WiFi AP access point router from China Tenda Company",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-35558"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014754"
},
{
"db": "CNVD",
"id": "CNVD-2022-75789"
},
{
"db": "VULMON",
"id": "CVE-2022-35558"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-35558",
"trust": 3.9
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014754",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-75789",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2837",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2022-35558",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75789"
},
{
"db": "VULMON",
"id": "CVE-2022-35558"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014754"
},
{
"db": "NVD",
"id": "CVE-2022-35558"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2837"
}
]
},
"id": "VAR-202208-0978",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75789"
}
],
"trust": 1.2666667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75789"
}
]
},
"last_update_date": "2023-12-18T14:03:50.025000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014754"
},
{
"db": "NVD",
"id": "CVE-2022-35558"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/ilovekeer/iot/tree/main/tenda/w6/stackoverflow/wifimacfilterget"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-35558"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-35558/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75789"
},
{
"db": "VULMON",
"id": "CVE-2022-35558"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014754"
},
{
"db": "NVD",
"id": "CVE-2022-35558"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2837"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-75789"
},
{
"db": "VULMON",
"id": "CVE-2022-35558"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014754"
},
{
"db": "NVD",
"id": "CVE-2022-35558"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2837"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-75789"
},
{
"date": "2022-08-12T00:00:00",
"db": "VULMON",
"id": "CVE-2022-35558"
},
{
"date": "2023-09-21T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-014754"
},
{
"date": "2022-08-12T15:15:15.737000",
"db": "NVD",
"id": "CVE-2022-35558"
},
{
"date": "2022-08-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-2837"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-75789"
},
{
"date": "2022-08-12T00:00:00",
"db": "VULMON",
"id": "CVE-2022-35558"
},
{
"date": "2023-09-21T08:08:00",
"db": "JVNDB",
"id": "JVNDB-2022-014754"
},
{
"date": "2022-08-16T14:50:37.237000",
"db": "NVD",
"id": "CVE-2022-35558"
},
{
"date": "2022-08-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-2837"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-2837"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w6\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014754"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-2837"
}
],
"trust": 0.6
}
}
VAR-202208-1091
Vulnerability from variot - Updated: 2023-12-18 13:42A stack overflow vulnerability exists in /goform/wifiSSIDget in Tenda W6 V1.0.0.9(4122) version, which can be exploited by attackers to cause a denial of service (DoS) via the index parameter. Shenzhen Tenda Technology Co.,Ltd. of w6 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda W6 is a wireless WiFi AP access point router from China Tenda Company
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202208-1091",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w6",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.9\\(4122\\)"
},
{
"model": "w6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w6 firmware 1.0.0.9(4122)"
},
{
"model": "w6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w6",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0.0.9(4122)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75786"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014755"
},
{
"db": "NVD",
"id": "CVE-2022-35557"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:w6_firmware:1.0.0.9\\(4122\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:w6:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-35557"
}
]
},
"cve": "CVE-2022-35557",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-75786",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-35557",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-35557",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2022-75786",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202208-2852",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75786"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014755"
},
{
"db": "NVD",
"id": "CVE-2022-35557"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2852"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A stack overflow vulnerability exists in /goform/wifiSSIDget in Tenda W6 V1.0.0.9(4122) version, which can be exploited by attackers to cause a denial of service (DoS) via the index parameter. Shenzhen Tenda Technology Co.,Ltd. of w6 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda W6 is a wireless WiFi AP access point router from China Tenda Company",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-35557"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014755"
},
{
"db": "CNVD",
"id": "CNVD-2022-75786"
},
{
"db": "VULMON",
"id": "CVE-2022-35557"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-35557",
"trust": 3.9
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014755",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-75786",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2852",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2022-35557",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75786"
},
{
"db": "VULMON",
"id": "CVE-2022-35557"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014755"
},
{
"db": "NVD",
"id": "CVE-2022-35557"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2852"
}
]
},
"id": "VAR-202208-1091",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75786"
}
],
"trust": 1.2666667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75786"
}
]
},
"last_update_date": "2023-12-18T13:42:00.409000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014755"
},
{
"db": "NVD",
"id": "CVE-2022-35557"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/ilovekeer/iot/tree/main/tenda/w6/stackoverflow/wifissidget"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-35557"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-35557/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75786"
},
{
"db": "VULMON",
"id": "CVE-2022-35557"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014755"
},
{
"db": "NVD",
"id": "CVE-2022-35557"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2852"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-75786"
},
{
"db": "VULMON",
"id": "CVE-2022-35557"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014755"
},
{
"db": "NVD",
"id": "CVE-2022-35557"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2852"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-75786"
},
{
"date": "2022-08-12T00:00:00",
"db": "VULMON",
"id": "CVE-2022-35557"
},
{
"date": "2023-09-21T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-014755"
},
{
"date": "2022-08-12T15:15:15.693000",
"db": "NVD",
"id": "CVE-2022-35557"
},
{
"date": "2022-08-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-2852"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-75786"
},
{
"date": "2022-08-12T00:00:00",
"db": "VULMON",
"id": "CVE-2022-35557"
},
{
"date": "2023-09-21T08:09:00",
"db": "JVNDB",
"id": "JVNDB-2022-014755"
},
{
"date": "2022-08-16T14:50:03.940000",
"db": "NVD",
"id": "CVE-2022-35557"
},
{
"date": "2022-08-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-2852"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-2852"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w6\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014755"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-2852"
}
],
"trust": 0.6
}
}
VAR-202208-1308
Vulnerability from variot - Updated: 2023-12-18 13:27A stack overflow vulnerability exists in /goform/WifiMacFilterSet in Tenda W6 V1.0.0.9(4122) version, which can be exploited by attackers to cause a denial of service (DoS) via the index parameter. Shenzhen Tenda Technology Co.,Ltd. of w6 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda W6 is a wireless WiFi AP access point router from China Tenda Company
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202208-1308",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w6",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.9\\(4122\\)"
},
{
"model": "w6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w6 firmware 1.0.0.9(4122)"
},
{
"model": "w6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w6",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0.0.9(4122)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75787"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014751"
},
{
"db": "NVD",
"id": "CVE-2022-35561"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:w6_firmware:1.0.0.9\\(4122\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:w6:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-35561"
}
]
},
"cve": "CVE-2022-35561",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-75787",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-35561",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-35561",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2022-75787",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202208-2846",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75787"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014751"
},
{
"db": "NVD",
"id": "CVE-2022-35561"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2846"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A stack overflow vulnerability exists in /goform/WifiMacFilterSet in Tenda W6 V1.0.0.9(4122) version, which can be exploited by attackers to cause a denial of service (DoS) via the index parameter. Shenzhen Tenda Technology Co.,Ltd. of w6 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda W6 is a wireless WiFi AP access point router from China Tenda Company",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-35561"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014751"
},
{
"db": "CNVD",
"id": "CNVD-2022-75787"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-35561",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014751",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-75787",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2846",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75787"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014751"
},
{
"db": "NVD",
"id": "CVE-2022-35561"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2846"
}
]
},
"id": "VAR-202208-1308",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75787"
}
],
"trust": 1.2666667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75787"
}
]
},
"last_update_date": "2023-12-18T13:27:04.851000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014751"
},
{
"db": "NVD",
"id": "CVE-2022-35561"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/ilovekeer/iot/tree/main/tenda/w6/stackoverflow/wifimacfilterset"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-35561"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-35561/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75787"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014751"
},
{
"db": "NVD",
"id": "CVE-2022-35561"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2846"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-75787"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014751"
},
{
"db": "NVD",
"id": "CVE-2022-35561"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2846"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-75787"
},
{
"date": "2023-09-21T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-014751"
},
{
"date": "2022-08-12T15:15:15.867000",
"db": "NVD",
"id": "CVE-2022-35561"
},
{
"date": "2022-08-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-2846"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-75787"
},
{
"date": "2023-09-21T08:08:00",
"db": "JVNDB",
"id": "JVNDB-2022-014751"
},
{
"date": "2022-08-16T14:53:31.823000",
"db": "NVD",
"id": "CVE-2022-35561"
},
{
"date": "2022-08-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-2846"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-2846"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w6\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014751"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-2846"
}
],
"trust": 0.6
}
}
VAR-202208-1040
Vulnerability from variot - Updated: 2023-12-18 13:11A stack overflow vulnerability exists in /goform/wifiSSIDset in Tenda W6 V1.0.0.9(4122) version, which can be exploited by attackers to cause a denial of service (DoS) via the index parameter. Shenzhen Tenda Technology Co.,Ltd. of w6 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda W6 is a wireless WiFi AP access point router from China Tenda Company
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202208-1040",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w6",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.9\\(4122\\)"
},
{
"model": "w6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w6 firmware 1.0.0.9(4122)"
},
{
"model": "w6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w6",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0.0.9(4122)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75788"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014752"
},
{
"db": "NVD",
"id": "CVE-2022-35560"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:w6_firmware:1.0.0.9\\(4122\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:w6:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-35560"
}
]
},
"cve": "CVE-2022-35560",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-75788",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-35560",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-35560",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2022-75788",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202208-2844",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75788"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014752"
},
{
"db": "NVD",
"id": "CVE-2022-35560"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2844"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A stack overflow vulnerability exists in /goform/wifiSSIDset in Tenda W6 V1.0.0.9(4122) version, which can be exploited by attackers to cause a denial of service (DoS) via the index parameter. Shenzhen Tenda Technology Co.,Ltd. of w6 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Tenda W6 is a wireless WiFi AP access point router from China Tenda Company",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-35560"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014752"
},
{
"db": "CNVD",
"id": "CNVD-2022-75788"
},
{
"db": "VULMON",
"id": "CVE-2022-35560"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-35560",
"trust": 3.9
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014752",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-75788",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2844",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2022-35560",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75788"
},
{
"db": "VULMON",
"id": "CVE-2022-35560"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014752"
},
{
"db": "NVD",
"id": "CVE-2022-35560"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2844"
}
]
},
"id": "VAR-202208-1040",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75788"
}
],
"trust": 1.2666667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75788"
}
]
},
"last_update_date": "2023-12-18T13:11:55.256000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014752"
},
{
"db": "NVD",
"id": "CVE-2022-35560"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/ilovekeer/iot/tree/main/tenda/w6/stackoverflow/wifissidset"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-35560"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-35560/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75788"
},
{
"db": "VULMON",
"id": "CVE-2022-35560"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014752"
},
{
"db": "NVD",
"id": "CVE-2022-35560"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2844"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-75788"
},
{
"db": "VULMON",
"id": "CVE-2022-35560"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014752"
},
{
"db": "NVD",
"id": "CVE-2022-35560"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2844"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-75788"
},
{
"date": "2022-08-12T00:00:00",
"db": "VULMON",
"id": "CVE-2022-35560"
},
{
"date": "2023-09-21T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-014752"
},
{
"date": "2022-08-12T15:15:15.820000",
"db": "NVD",
"id": "CVE-2022-35560"
},
{
"date": "2022-08-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-2844"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-75788"
},
{
"date": "2022-08-12T00:00:00",
"db": "VULMON",
"id": "CVE-2022-35560"
},
{
"date": "2023-09-21T08:08:00",
"db": "JVNDB",
"id": "JVNDB-2022-014752"
},
{
"date": "2022-08-16T14:53:02.307000",
"db": "NVD",
"id": "CVE-2022-35560"
},
{
"date": "2022-08-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-2844"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-2844"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w6\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014752"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-2844"
}
],
"trust": 0.6
}
}
VAR-202208-1042
Vulnerability from variot - Updated: 2023-12-18 12:54A stack overflow vulnerability exists in /goform/setAutoPing in Tenda W6 V1.0.0.9(4122), which allows an attacker to construct ping1 parameters and ping2 parameters for a stack overflow attack. An attacker can use this vulnerability to execute arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of w6 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda W6 is a wireless WiFi AP access point router from China Tenda Company
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202208-1042",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w6",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.9\\(4122\\)"
},
{
"model": "w6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w6 firmware 1.0.0.9(4122)"
},
{
"model": "w6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w6",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0.0.9(4122)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75819"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014753"
},
{
"db": "NVD",
"id": "CVE-2022-35559"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:w6_firmware:1.0.0.9\\(4122\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:w6:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-35559"
}
]
},
"cve": "CVE-2022-35559",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-75819",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-35559",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-35559",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2022-75819",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202208-2835",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75819"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014753"
},
{
"db": "NVD",
"id": "CVE-2022-35559"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2835"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A stack overflow vulnerability exists in /goform/setAutoPing in Tenda W6 V1.0.0.9(4122), which allows an attacker to construct ping1 parameters and ping2 parameters for a stack overflow attack. An attacker can use this vulnerability to execute arbitrary code execution. Shenzhen Tenda Technology Co.,Ltd. of w6 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda W6 is a wireless WiFi AP access point router from China Tenda Company",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-35559"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014753"
},
{
"db": "CNVD",
"id": "CNVD-2022-75819"
},
{
"db": "VULMON",
"id": "CVE-2022-35559"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-35559",
"trust": 3.9
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014753",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-75819",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2835",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2022-35559",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75819"
},
{
"db": "VULMON",
"id": "CVE-2022-35559"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014753"
},
{
"db": "NVD",
"id": "CVE-2022-35559"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2835"
}
]
},
"id": "VAR-202208-1042",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75819"
}
],
"trust": 1.2666667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75819"
}
]
},
"last_update_date": "2023-12-18T12:54:51.197000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014753"
},
{
"db": "NVD",
"id": "CVE-2022-35559"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/ilovekeer/iot/tree/main/tenda/w6/stackoverflow/formsetautoping"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-35559"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-35559/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75819"
},
{
"db": "VULMON",
"id": "CVE-2022-35559"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014753"
},
{
"db": "NVD",
"id": "CVE-2022-35559"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2835"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-75819"
},
{
"db": "VULMON",
"id": "CVE-2022-35559"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014753"
},
{
"db": "NVD",
"id": "CVE-2022-35559"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2835"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-75819"
},
{
"date": "2022-08-12T00:00:00",
"db": "VULMON",
"id": "CVE-2022-35559"
},
{
"date": "2023-09-21T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-014753"
},
{
"date": "2022-08-12T15:15:15.777000",
"db": "NVD",
"id": "CVE-2022-35559"
},
{
"date": "2022-08-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-2835"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-75819"
},
{
"date": "2022-08-12T00:00:00",
"db": "VULMON",
"id": "CVE-2022-35559"
},
{
"date": "2023-09-21T08:08:00",
"db": "JVNDB",
"id": "JVNDB-2022-014753"
},
{
"date": "2022-08-16T14:52:03",
"db": "NVD",
"id": "CVE-2022-35559"
},
{
"date": "2022-08-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-2835"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-2835"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w6\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014753"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-2835"
}
],
"trust": 0.6
}
}
VAR-202208-1092
Vulnerability from variot - Updated: 2023-12-18 12:48A command injection vulnerability exists in /goform/exeCommand in Tenda W6 V1.0.0.9(4122), which allows attackers to construct cmdinput parameters for arbitrary command execution. Shenzhen Tenda Technology Co.,Ltd. of w6 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda W6 is a wireless WiFi AP access point router from China Tenda Company
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202208-1092",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w6",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.9\\(4122\\)"
},
{
"model": "w6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w6 firmware 1.0.0.9(4122)"
},
{
"model": "w6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w6",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0.0.9(4122)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75818"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014756"
},
{
"db": "NVD",
"id": "CVE-2022-35555"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:w6_firmware:1.0.0.9\\(4122\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:w6:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-35555"
}
]
},
"cve": "CVE-2022-35555",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-75818",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-35555",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-35555",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2022-75818",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202208-2836",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75818"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014756"
},
{
"db": "NVD",
"id": "CVE-2022-35555"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2836"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A command injection vulnerability exists in /goform/exeCommand in Tenda W6 V1.0.0.9(4122), which allows attackers to construct cmdinput parameters for arbitrary command execution. Shenzhen Tenda Technology Co.,Ltd. of w6 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda W6 is a wireless WiFi AP access point router from China Tenda Company",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-35555"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014756"
},
{
"db": "CNVD",
"id": "CNVD-2022-75818"
},
{
"db": "VULMON",
"id": "CVE-2022-35555"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-35555",
"trust": 3.9
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014756",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-75818",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2836",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2022-35555",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75818"
},
{
"db": "VULMON",
"id": "CVE-2022-35555"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014756"
},
{
"db": "NVD",
"id": "CVE-2022-35555"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2836"
}
]
},
"id": "VAR-202208-1092",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75818"
}
],
"trust": 1.2666667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75818"
}
]
},
"last_update_date": "2023-12-18T12:48:34.142000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.0
},
{
"problemtype": "OS Command injection (CWE-78) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014756"
},
{
"db": "NVD",
"id": "CVE-2022-35555"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/ilovekeer/iot/blob/main/tenda/w6/injection/execommand/readme.md"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-35555"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-35555/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75818"
},
{
"db": "VULMON",
"id": "CVE-2022-35555"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014756"
},
{
"db": "NVD",
"id": "CVE-2022-35555"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2836"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-75818"
},
{
"db": "VULMON",
"id": "CVE-2022-35555"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014756"
},
{
"db": "NVD",
"id": "CVE-2022-35555"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2836"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-75818"
},
{
"date": "2022-08-12T00:00:00",
"db": "VULMON",
"id": "CVE-2022-35555"
},
{
"date": "2023-09-21T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-014756"
},
{
"date": "2022-08-12T15:15:15.647000",
"db": "NVD",
"id": "CVE-2022-35555"
},
{
"date": "2022-08-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-2836"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-75818"
},
{
"date": "2022-08-12T00:00:00",
"db": "VULMON",
"id": "CVE-2022-35555"
},
{
"date": "2023-09-21T08:09:00",
"db": "JVNDB",
"id": "JVNDB-2022-014756"
},
{
"date": "2023-08-08T14:21:49.707000",
"db": "NVD",
"id": "CVE-2022-35555"
},
{
"date": "2022-08-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-2836"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-2836"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W6 Command Injection Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-75818"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2836"
}
],
"trust": 1.2
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "command injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-2836"
}
],
"trust": 0.6
}
}
CVE-2024-0995 (GCVE-0-2024-0995)
Vulnerability from cvelistv5 – Published: 2024-01-29 02:00 – Updated: 2025-06-02 19:12- CWE-121 - Stack-based Buffer Overflow
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:26:30.371Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.252260"
},
{
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.252260"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://jylsec.notion.site/Tenda-w6-has-stack-buffer-overflow-vulnerability-in-formwrlSSIDset-e283b41905934e97b4c65632a0018eba?pvs=4"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0995",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-02T19:11:50.794914Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-02T19:12:09.219Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "W6",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.9(4122)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been rated as critical. Affected by this issue is the function formwrlSSIDset of the file /goform/wifiSSIDset of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252260. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda W6 1.0.0.9(4122) ausgemacht. Davon betroffen ist die Funktion formwrlSSIDset der Datei /goform/wifiSSIDset der Komponente httpd. Durch Manipulieren des Arguments index mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 8.3,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-29T02:00:08.977Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.252260"
},
{
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.252260"
},
{
"tags": [
"exploit"
],
"url": "https://jylsec.notion.site/Tenda-w6-has-stack-buffer-overflow-vulnerability-in-formwrlSSIDset-e283b41905934e97b4c65632a0018eba?pvs=4"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-01-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-01-28T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-01-28T16:45:01.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda W6 httpd wifiSSIDset formwrlSSIDset stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-0995",
"datePublished": "2024-01-29T02:00:08.977Z",
"dateReserved": "2024-01-28T15:39:38.873Z",
"dateUpdated": "2025-06-02T19:12:09.219Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0994 (GCVE-0-2024-0994)
Vulnerability from cvelistv5 – Published: 2024-01-29 01:31 – Updated: 2024-11-12 21:48- CWE-121 - Stack-based Buffer Overflow
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:26:30.342Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.252259"
},
{
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.252259"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://jylsec.notion.site/Tenda-W6-has-stack-buffer-overflow-vulnerability-in-formSetCfm-4fab28f92ca74f519245b606d8345821?pvs=4"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0994",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-12T21:48:15.464034Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T21:48:39.140Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "W6",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.9(4122)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been declared as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252259. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda W6 1.0.0.9(4122) wurde eine kritische Schwachstelle ausgemacht. Hierbei betrifft es die Funktion formSetCfm der Datei /goform/setcfm der Komponente httpd. Durch das Manipulieren des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 8.3,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-29T01:31:05.266Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.252259"
},
{
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.252259"
},
{
"tags": [
"exploit"
],
"url": "https://jylsec.notion.site/Tenda-W6-has-stack-buffer-overflow-vulnerability-in-formSetCfm-4fab28f92ca74f519245b606d8345821?pvs=4"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-01-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-01-28T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-01-28T16:44:59.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda W6 httpd setcfm formSetCfm stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-0994",
"datePublished": "2024-01-29T01:31:05.266Z",
"dateReserved": "2024-01-28T15:39:35.248Z",
"dateUpdated": "2024-11-12T21:48:39.140Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0995 (GCVE-0-2024-0995)
Vulnerability from nvd – Published: 2024-01-29 02:00 – Updated: 2025-06-02 19:12- CWE-121 - Stack-based Buffer Overflow
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:26:30.371Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.252260"
},
{
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.252260"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://jylsec.notion.site/Tenda-w6-has-stack-buffer-overflow-vulnerability-in-formwrlSSIDset-e283b41905934e97b4c65632a0018eba?pvs=4"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0995",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-02T19:11:50.794914Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-02T19:12:09.219Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "W6",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.9(4122)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been rated as critical. Affected by this issue is the function formwrlSSIDset of the file /goform/wifiSSIDset of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252260. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda W6 1.0.0.9(4122) ausgemacht. Davon betroffen ist die Funktion formwrlSSIDset der Datei /goform/wifiSSIDset der Komponente httpd. Durch Manipulieren des Arguments index mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 8.3,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-29T02:00:08.977Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.252260"
},
{
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.252260"
},
{
"tags": [
"exploit"
],
"url": "https://jylsec.notion.site/Tenda-w6-has-stack-buffer-overflow-vulnerability-in-formwrlSSIDset-e283b41905934e97b4c65632a0018eba?pvs=4"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-01-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-01-28T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-01-28T16:45:01.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda W6 httpd wifiSSIDset formwrlSSIDset stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-0995",
"datePublished": "2024-01-29T02:00:08.977Z",
"dateReserved": "2024-01-28T15:39:38.873Z",
"dateUpdated": "2025-06-02T19:12:09.219Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0994 (GCVE-0-2024-0994)
Vulnerability from nvd – Published: 2024-01-29 01:31 – Updated: 2024-11-12 21:48- CWE-121 - Stack-based Buffer Overflow
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:26:30.342Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.252259"
},
{
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.252259"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://jylsec.notion.site/Tenda-W6-has-stack-buffer-overflow-vulnerability-in-formSetCfm-4fab28f92ca74f519245b606d8345821?pvs=4"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0994",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-12T21:48:15.464034Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T21:48:39.140Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "W6",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.9(4122)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been declared as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252259. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda W6 1.0.0.9(4122) wurde eine kritische Schwachstelle ausgemacht. Hierbei betrifft es die Funktion formSetCfm der Datei /goform/setcfm der Komponente httpd. Durch das Manipulieren des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 8.3,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-29T01:31:05.266Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.252259"
},
{
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.252259"
},
{
"tags": [
"exploit"
],
"url": "https://jylsec.notion.site/Tenda-W6-has-stack-buffer-overflow-vulnerability-in-formSetCfm-4fab28f92ca74f519245b606d8345821?pvs=4"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-01-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-01-28T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-01-28T16:44:59.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda W6 httpd setcfm formSetCfm stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-0994",
"datePublished": "2024-01-29T01:31:05.266Z",
"dateReserved": "2024-01-28T15:39:35.248Z",
"dateUpdated": "2024-11-12T21:48:39.140Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}