Search criteria
18 vulnerabilities found for wiser_smart_eer21000_firmware by schneider-electric
FKIE_CVE-2022-30237
Vulnerability from fkie_nvd - Published: 2022-06-02 23:15 - Updated: 2024-11-21 07:02
Severity ?
8.2 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Summary
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
References
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://www.se.com/ww/en/download/document/SEVD-2022-130-03/ | Mitigation, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.se.com/ww/en/download/document/SEVD-2022-130-03/ | Mitigation, Vendor Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5FF54835-9F49-417D-985F-24799D9B93A0",
"versionEndIncluding": "4.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E5552670-EDA0-4C30-B292-2228FB418A38",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21001_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B3E7CC55-F222-470E-AA71-DEECB4A971F6",
"versionEndIncluding": "4.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21001:-:*:*:*:*:*:*:*",
"matchCriteriaId": "68D3AC8F-AA3E-4173-89FB-6F8EA59FA52B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
},
{
"lang": "es",
"value": "Una CWE-311: Se presenta una vulnerabilidad de Falta de Encriptaci\u00f3n de Datos Confidenciales que podr\u00eda permitir recuperar las credenciales de autenticaci\u00f3n cuando un atacante rompe la codificaci\u00f3n. Productos afectados: Wiser Smart, EER21000 y EER21001 (versiones V4.5 y anteriores)"
}
],
"id": "CVE-2022-30237",
"lastModified": "2024-11-21T07:02:25.763",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 4.2,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-06-02T23:15:07.730",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-311"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
}
FKIE_CVE-2022-30233
Vulnerability from fkie_nvd - Published: 2022-06-02 23:15 - Updated: 2024-11-21 07:02
Severity ?
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N
Summary
A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
References
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://www.se.com/ww/en/download/document/SEVD-2022-130-03/ | Mitigation, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.se.com/ww/en/download/document/SEVD-2022-130-03/ | Mitigation, Vendor Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5FF54835-9F49-417D-985F-24799D9B93A0",
"versionEndIncluding": "4.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E5552670-EDA0-4C30-B292-2228FB418A38",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21001_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B3E7CC55-F222-470E-AA71-DEECB4A971F6",
"versionEndIncluding": "4.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21001:-:*:*:*:*:*:*:*",
"matchCriteriaId": "68D3AC8F-AA3E-4173-89FB-6F8EA59FA52B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
},
{
"lang": "es",
"value": "Una CWE-20: Se presenta una vulnerabilidad de Comprobaci\u00f3n de Entrada Inapropiada que podr\u00eda permitir una manipulaci\u00f3n maliciosa del producto cuando es enga\u00f1ado al usuario para que lleve a cabo determinadas acciones en una p\u00e1gina web. Productos afectados: Wiser Smart, EER21000 y EER21001 (versiones V4.5 y anteriores)"
}
],
"id": "CVE-2022-30233",
"lastModified": "2024-11-21T07:02:25.277",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-06-02T23:15:07.507",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
}
FKIE_CVE-2022-30234
Vulnerability from fkie_nvd - Published: 2022-06-02 23:15 - Updated: 2024-11-21 07:02
Severity ?
9.4 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
References
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://www.se.com/ww/en/download/document/SEVD-2022-130-03/ | Mitigation, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.se.com/ww/en/download/document/SEVD-2022-130-03/ | Mitigation, Vendor Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5FF54835-9F49-417D-985F-24799D9B93A0",
"versionEndIncluding": "4.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E5552670-EDA0-4C30-B292-2228FB418A38",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21001_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B3E7CC55-F222-470E-AA71-DEECB4A971F6",
"versionEndIncluding": "4.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21001:-:*:*:*:*:*:*:*",
"matchCriteriaId": "68D3AC8F-AA3E-4173-89FB-6F8EA59FA52B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
},
{
"lang": "es",
"value": "Una CWE-798: Se presenta una vulnerabilidad en el Uso de Credenciales Embebidas que podr\u00eda permitir la ejecuci\u00f3n de c\u00f3digo arbitrario cuando es obtenido acceso a nivel root. Productos afectados: Wiser Smart, EER21000 y EER21001 (versiones V4.5 y anteriores)"
}
],
"id": "CVE-2022-30234",
"lastModified": "2024-11-21T07:02:25.400",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.5,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-06-02T23:15:07.560",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
}
FKIE_CVE-2022-30235
Vulnerability from fkie_nvd - Published: 2022-06-02 23:15 - Updated: 2024-11-21 07:02
Severity ?
8.6 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
References
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://www.se.com/ww/en/download/document/SEVD-2022-130-03/ | Mitigation, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.se.com/ww/en/download/document/SEVD-2022-130-03/ | Mitigation, Vendor Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5FF54835-9F49-417D-985F-24799D9B93A0",
"versionEndIncluding": "4.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E5552670-EDA0-4C30-B292-2228FB418A38",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21001_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B3E7CC55-F222-470E-AA71-DEECB4A971F6",
"versionEndIncluding": "4.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21001:-:*:*:*:*:*:*:*",
"matchCriteriaId": "68D3AC8F-AA3E-4173-89FB-6F8EA59FA52B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
},
{
"lang": "es",
"value": "Una CWE-307: Se presenta una vulnerabilidad de Restricci\u00f3n Inapropiada de intentos de Autenticaci\u00f3n Excesivos que podr\u00eda permitir el acceso no autorizado cuando un atacante usa fuerza bruta. Productos afectados: Wiser Smart, EER21000 y EER21001 (versiones V4.5 y anteriores)"
}
],
"id": "CVE-2022-30235",
"lastModified": "2024-11-21T07:02:25.523",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 4.0,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-06-02T23:15:07.617",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-307"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
}
FKIE_CVE-2022-30238
Vulnerability from fkie_nvd - Published: 2022-06-02 23:15 - Updated: 2024-11-21 07:02
Severity ?
8.3 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
References
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://www.se.com/ww/en/download/document/SEVD-2022-130-03/ | Mitigation, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.se.com/ww/en/download/document/SEVD-2022-130-03/ | Mitigation, Vendor Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5FF54835-9F49-417D-985F-24799D9B93A0",
"versionEndIncluding": "4.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E5552670-EDA0-4C30-B292-2228FB418A38",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21001_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B3E7CC55-F222-470E-AA71-DEECB4A971F6",
"versionEndIncluding": "4.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21001:-:*:*:*:*:*:*:*",
"matchCriteriaId": "68D3AC8F-AA3E-4173-89FB-6F8EA59FA52B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
},
{
"lang": "es",
"value": "UNA CWE-287: Se presenta una vulnerabilidad de Autenticaci\u00f3n Inapropiada que podr\u00eda permitir a un atacante tomar el control de la cuenta de administrador cuando un atacante secuestra una sesi\u00f3n. Productos afectados: Wiser Smart, EER21000 y EER21001 (versiones V4.5 y anteriores)"
}
],
"id": "CVE-2022-30238",
"lastModified": "2024-11-21T07:02:25.880",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.5,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-06-02T23:15:07.787",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
}
FKIE_CVE-2022-30236
Vulnerability from fkie_nvd - Published: 2022-06-02 23:15 - Updated: 2024-11-21 07:02
Severity ?
8.2 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N
8.2 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N
8.2 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N
Summary
A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
References
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://www.se.com/ww/en/download/document/SEVD-2022-130-03/ | Mitigation, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.se.com/ww/en/download/document/SEVD-2022-130-03/ | Mitigation, Vendor Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5FF54835-9F49-417D-985F-24799D9B93A0",
"versionEndIncluding": "4.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E5552670-EDA0-4C30-B292-2228FB418A38",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21001_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B3E7CC55-F222-470E-AA71-DEECB4A971F6",
"versionEndIncluding": "4.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21001:-:*:*:*:*:*:*:*",
"matchCriteriaId": "68D3AC8F-AA3E-4173-89FB-6F8EA59FA52B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
},
{
"lang": "es",
"value": "Una CWE-669: Se presenta una vulnerabilidad de Transferencia Incorrecta de Recursos Entre Esferas que podr\u00eda permitir el acceso no autorizado cuando un atacante usa ataques entre dominios. Productos afectados: Wiser Smart, EER21000 y EER21001 (versiones V4.5 y anteriores)"
}
],
"id": "CVE-2022-30236",
"lastModified": "2024-11-21T07:02:25.647",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 6.4,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 4.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 4.2,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 4.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-06-02T23:15:07.673",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-669"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
}
CVE-2022-30238 (GCVE-0-2022-30238)
Vulnerability from cvelistv5 – Published: 2022-06-02 22:45 – Updated: 2024-09-17 03:29
VLAI?
Summary
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
Severity ?
8.3 (High)
CWE
- CWE-287 - Improper Authentication
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Wiser Smart |
Affected:
EER21000 , < 4.5
(custom)
Affected: EER21001 , < 4.5 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:40:47.892Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wiser Smart",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21000",
"versionType": "custom"
},
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21001",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-05-10T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-02T22:45:25",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2022-05-10T07:00:00.000Z",
"ID": "CVE-2022-30238",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wiser Smart",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "EER21000",
"version_value": "4.5"
},
{
"version_affected": "\u003c",
"version_name": "EER21001",
"version_value": "4.5"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287 Improper Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-30238",
"datePublished": "2022-06-02T22:45:25.728616Z",
"dateReserved": "2022-05-04T00:00:00",
"dateUpdated": "2024-09-17T03:29:08.122Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-30237 (GCVE-0-2022-30237)
Vulnerability from cvelistv5 – Published: 2022-06-02 22:45 – Updated: 2024-09-17 01:57
VLAI?
Summary
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
Severity ?
8.2 (High)
CWE
- CWE-311 - Missing Encryption of Sensitive Data
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Wiser Smart |
Affected:
EER21000 , < 4.5
(custom)
Affected: EER21001 , < 4.5 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:40:47.884Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wiser Smart",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21000",
"versionType": "custom"
},
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21001",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-05-10T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-311",
"description": "CWE-311 Missing Encryption of Sensitive Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-02T22:45:24",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2022-05-10T07:00:00.000Z",
"ID": "CVE-2022-30237",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wiser Smart",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "EER21000",
"version_value": "4.5"
},
{
"version_affected": "\u003c",
"version_name": "EER21001",
"version_value": "4.5"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-311 Missing Encryption of Sensitive Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-30237",
"datePublished": "2022-06-02T22:45:24.206860Z",
"dateReserved": "2022-05-04T00:00:00",
"dateUpdated": "2024-09-17T01:57:03.909Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-30236 (GCVE-0-2022-30236)
Vulnerability from cvelistv5 – Published: 2022-06-02 22:45 – Updated: 2024-09-16 23:00
VLAI?
Summary
A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
Severity ?
8.2 (High)
CWE
- CWE-669 - Incorrect Resource Transfer Between Spheres
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Wiser Smart |
Affected:
EER21000 , < 4.5
(custom)
Affected: EER21001 , < 4.5 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:40:47.838Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wiser Smart",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21000",
"versionType": "custom"
},
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21001",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-05-10T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-669",
"description": "CWE-669 Incorrect Resource Transfer Between Spheres",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-02T22:45:22",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2022-05-10T07:00:00.000Z",
"ID": "CVE-2022-30236",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wiser Smart",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "EER21000",
"version_value": "4.5"
},
{
"version_affected": "\u003c",
"version_name": "EER21001",
"version_value": "4.5"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-669 Incorrect Resource Transfer Between Spheres"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-30236",
"datePublished": "2022-06-02T22:45:22.767960Z",
"dateReserved": "2022-05-04T00:00:00",
"dateUpdated": "2024-09-16T23:00:39.820Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-30235 (GCVE-0-2022-30235)
Vulnerability from cvelistv5 – Published: 2022-06-02 22:45 – Updated: 2024-09-16 17:59
VLAI?
Summary
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
Severity ?
8.6 (High)
CWE
- CWE-307 - Improper Restriction of Excessive Authentication Attempts
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Wiser Smart |
Affected:
EER21000 , < 4.5
(custom)
Affected: EER21001 , < 4.5 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:40:47.777Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wiser Smart",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21000",
"versionType": "custom"
},
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21001",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-05-10T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-307",
"description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-02T22:45:21",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2022-05-10T07:00:00.000Z",
"ID": "CVE-2022-30235",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wiser Smart",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "EER21000",
"version_value": "4.5"
},
{
"version_affected": "\u003c",
"version_name": "EER21001",
"version_value": "4.5"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-307 Improper Restriction of Excessive Authentication Attempts"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-30235",
"datePublished": "2022-06-02T22:45:21.168189Z",
"dateReserved": "2022-05-04T00:00:00",
"dateUpdated": "2024-09-16T17:59:43.987Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-30234 (GCVE-0-2022-30234)
Vulnerability from cvelistv5 – Published: 2022-06-02 22:45 – Updated: 2024-09-16 19:04
VLAI?
Summary
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
Severity ?
9.4 (Critical)
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Wiser Smart |
Affected:
EER21000 , < 4.5
(custom)
Affected: EER21001 , < 4.5 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:40:47.793Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wiser Smart",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21000",
"versionType": "custom"
},
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21001",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-05-10T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-02T22:45:19",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2022-05-10T07:00:00.000Z",
"ID": "CVE-2022-30234",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wiser Smart",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "EER21000",
"version_value": "4.5"
},
{
"version_affected": "\u003c",
"version_name": "EER21001",
"version_value": "4.5"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-798 Use of Hard-coded Credentials"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-30234",
"datePublished": "2022-06-02T22:45:19.768519Z",
"dateReserved": "2022-05-04T00:00:00",
"dateUpdated": "2024-09-16T19:04:21.194Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-30233 (GCVE-0-2022-30233)
Vulnerability from cvelistv5 – Published: 2022-06-02 22:45 – Updated: 2024-09-17 03:29
VLAI?
Summary
A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Wiser Smart |
Affected:
EER21000 , < 4.5
(custom)
Affected: EER21001 , < 4.5 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:40:47.832Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wiser Smart",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21000",
"versionType": "custom"
},
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21001",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-05-10T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-02T22:45:18",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2022-05-10T07:00:00.000Z",
"ID": "CVE-2022-30233",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wiser Smart",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "EER21000",
"version_value": "4.5"
},
{
"version_affected": "\u003c",
"version_name": "EER21001",
"version_value": "4.5"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20 Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-30233",
"datePublished": "2022-06-02T22:45:18.223723Z",
"dateReserved": "2022-05-04T00:00:00",
"dateUpdated": "2024-09-17T03:29:05.313Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-30238 (GCVE-0-2022-30238)
Vulnerability from nvd – Published: 2022-06-02 22:45 – Updated: 2024-09-17 03:29
VLAI?
Summary
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
Severity ?
8.3 (High)
CWE
- CWE-287 - Improper Authentication
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Wiser Smart |
Affected:
EER21000 , < 4.5
(custom)
Affected: EER21001 , < 4.5 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:40:47.892Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wiser Smart",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21000",
"versionType": "custom"
},
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21001",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-05-10T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-02T22:45:25",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2022-05-10T07:00:00.000Z",
"ID": "CVE-2022-30238",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wiser Smart",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "EER21000",
"version_value": "4.5"
},
{
"version_affected": "\u003c",
"version_name": "EER21001",
"version_value": "4.5"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287 Improper Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-30238",
"datePublished": "2022-06-02T22:45:25.728616Z",
"dateReserved": "2022-05-04T00:00:00",
"dateUpdated": "2024-09-17T03:29:08.122Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-30237 (GCVE-0-2022-30237)
Vulnerability from nvd – Published: 2022-06-02 22:45 – Updated: 2024-09-17 01:57
VLAI?
Summary
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
Severity ?
8.2 (High)
CWE
- CWE-311 - Missing Encryption of Sensitive Data
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Wiser Smart |
Affected:
EER21000 , < 4.5
(custom)
Affected: EER21001 , < 4.5 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:40:47.884Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wiser Smart",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21000",
"versionType": "custom"
},
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21001",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-05-10T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-311",
"description": "CWE-311 Missing Encryption of Sensitive Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-02T22:45:24",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2022-05-10T07:00:00.000Z",
"ID": "CVE-2022-30237",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wiser Smart",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "EER21000",
"version_value": "4.5"
},
{
"version_affected": "\u003c",
"version_name": "EER21001",
"version_value": "4.5"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-311 Missing Encryption of Sensitive Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-30237",
"datePublished": "2022-06-02T22:45:24.206860Z",
"dateReserved": "2022-05-04T00:00:00",
"dateUpdated": "2024-09-17T01:57:03.909Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-30236 (GCVE-0-2022-30236)
Vulnerability from nvd – Published: 2022-06-02 22:45 – Updated: 2024-09-16 23:00
VLAI?
Summary
A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
Severity ?
8.2 (High)
CWE
- CWE-669 - Incorrect Resource Transfer Between Spheres
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Wiser Smart |
Affected:
EER21000 , < 4.5
(custom)
Affected: EER21001 , < 4.5 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:40:47.838Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wiser Smart",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21000",
"versionType": "custom"
},
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21001",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-05-10T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-669",
"description": "CWE-669 Incorrect Resource Transfer Between Spheres",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-02T22:45:22",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2022-05-10T07:00:00.000Z",
"ID": "CVE-2022-30236",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wiser Smart",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "EER21000",
"version_value": "4.5"
},
{
"version_affected": "\u003c",
"version_name": "EER21001",
"version_value": "4.5"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-669 Incorrect Resource Transfer Between Spheres"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-30236",
"datePublished": "2022-06-02T22:45:22.767960Z",
"dateReserved": "2022-05-04T00:00:00",
"dateUpdated": "2024-09-16T23:00:39.820Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-30235 (GCVE-0-2022-30235)
Vulnerability from nvd – Published: 2022-06-02 22:45 – Updated: 2024-09-16 17:59
VLAI?
Summary
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
Severity ?
8.6 (High)
CWE
- CWE-307 - Improper Restriction of Excessive Authentication Attempts
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Wiser Smart |
Affected:
EER21000 , < 4.5
(custom)
Affected: EER21001 , < 4.5 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:40:47.777Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wiser Smart",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21000",
"versionType": "custom"
},
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21001",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-05-10T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-307",
"description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-02T22:45:21",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2022-05-10T07:00:00.000Z",
"ID": "CVE-2022-30235",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wiser Smart",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "EER21000",
"version_value": "4.5"
},
{
"version_affected": "\u003c",
"version_name": "EER21001",
"version_value": "4.5"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-307 Improper Restriction of Excessive Authentication Attempts"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-30235",
"datePublished": "2022-06-02T22:45:21.168189Z",
"dateReserved": "2022-05-04T00:00:00",
"dateUpdated": "2024-09-16T17:59:43.987Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-30234 (GCVE-0-2022-30234)
Vulnerability from nvd – Published: 2022-06-02 22:45 – Updated: 2024-09-16 19:04
VLAI?
Summary
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
Severity ?
9.4 (Critical)
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Wiser Smart |
Affected:
EER21000 , < 4.5
(custom)
Affected: EER21001 , < 4.5 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:40:47.793Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wiser Smart",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21000",
"versionType": "custom"
},
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21001",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-05-10T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-02T22:45:19",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2022-05-10T07:00:00.000Z",
"ID": "CVE-2022-30234",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wiser Smart",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "EER21000",
"version_value": "4.5"
},
{
"version_affected": "\u003c",
"version_name": "EER21001",
"version_value": "4.5"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-798 Use of Hard-coded Credentials"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-30234",
"datePublished": "2022-06-02T22:45:19.768519Z",
"dateReserved": "2022-05-04T00:00:00",
"dateUpdated": "2024-09-16T19:04:21.194Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-30233 (GCVE-0-2022-30233)
Vulnerability from nvd – Published: 2022-06-02 22:45 – Updated: 2024-09-17 03:29
VLAI?
Summary
A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Wiser Smart |
Affected:
EER21000 , < 4.5
(custom)
Affected: EER21001 , < 4.5 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:40:47.832Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wiser Smart",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21000",
"versionType": "custom"
},
{
"lessThan": "4.5",
"status": "affected",
"version": "EER21001",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-05-10T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-02T22:45:18",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2022-05-10T07:00:00.000Z",
"ID": "CVE-2022-30233",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wiser Smart",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "EER21000",
"version_value": "4.5"
},
{
"version_affected": "\u003c",
"version_name": "EER21001",
"version_value": "4.5"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20 Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-30233",
"datePublished": "2022-06-02T22:45:18.223723Z",
"dateReserved": "2022-05-04T00:00:00",
"dateUpdated": "2024-09-17T03:29:05.313Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}