Search criteria
17 vulnerabilities by B. Braun Melsungen AG
CVE-2025-3365 (GCVE-0-2025-3365)
Vulnerability from cvelistv5 – Published: 2025-06-06 08:14 – Updated: 2025-06-06 17:12
VLAI?
Summary
A missing protection against path traversal allows to access
any file on the server.
Severity ?
9.8 (Critical)
CWE
- CWE-23 - Relative Path Traversal
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B. Braun Melsungen AG | OnlineSuite |
Affected:
3.0
(custom)
|
Credits
Fabian Weber (CODE WHITE GmbH)
Dr. Florian Hauser (CODE WHITE GmbH)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3365",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-06T17:03:10.577417Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-06T17:12:51.401Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "OnlineSuite",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"status": "affected",
"version": "3.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Fabian Weber (CODE WHITE GmbH)"
},
{
"lang": "en",
"type": "reporter",
"value": "Dr. Florian Hauser (CODE WHITE GmbH)"
}
],
"datePublic": "2025-06-06T07:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA missing protection against path traversal allows to access\nany file on the server.\u003c/p\u003e"
}
],
"value": "A missing protection against path traversal allows to access\nany file on the server."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-23",
"description": "CWE-23 Relative Path Traversal",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-06T08:14:00.444Z",
"orgId": "653264ec-f98b-4e8f-b8b4-540a01b7657d",
"shortName": "B.Braun"
},
"references": [
{
"url": "https://www.bbraun.com/productsecurity"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Field Service Information FSI 14-25 \u201cOnlineSuite AP3.0 - Security Fix\u201d provides a patch to these issues.\n\n\u003cbr\u003e"
}
],
"value": "Field Service Information FSI 14-25 \u201cOnlineSuite AP3.0 - Security Fix\u201d provides a patch to these issues."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Relative Path Traversal in OnlineSuite",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "653264ec-f98b-4e8f-b8b4-540a01b7657d",
"assignerShortName": "B.Braun",
"cveId": "CVE-2025-3365",
"datePublished": "2025-06-06T08:14:00.444Z",
"dateReserved": "2025-04-07T06:11:11.032Z",
"dateUpdated": "2025-06-06T17:12:51.401Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3322 (GCVE-0-2025-3322)
Vulnerability from cvelistv5 – Published: 2025-06-06 08:13 – Updated: 2025-06-06 17:29
VLAI?
Summary
An improper neutralization of inputs used in expression
language allows remote code execution with the highest privileges on the
server.
Severity ?
CWE
- CWE-917 - Improper Neutralization of Special Elements used in an Expression Language Statement ('Expression Language Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B. Braun Melsungen AG | OnlineSuite |
Affected:
3.0
(custom)
|
Credits
Fabian Weber (CODE WHITE GmbH)
Dr. Florian Hauser (CODE WHITE GmbH)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3322",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-06T17:19:28.552605Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-06T17:29:30.972Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "OnlineSuite",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"status": "affected",
"version": "3.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Fabian Weber (CODE WHITE GmbH)"
},
{
"lang": "en",
"type": "reporter",
"value": "Dr. Florian Hauser (CODE WHITE GmbH)"
}
],
"datePublic": "2025-06-06T07:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn improper neutralization of inputs used in expression\nlanguage allows remote code execution with the highest privileges on the\nserver.\u003c/p\u003e"
}
],
"value": "An improper neutralization of inputs used in expression\nlanguage allows remote code execution with the highest privileges on the\nserver."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-917",
"description": "CWE-917 Improper Neutralization of Special Elements used in an Expression Language Statement (\u0027Expression Language Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-06T08:13:12.028Z",
"orgId": "653264ec-f98b-4e8f-b8b4-540a01b7657d",
"shortName": "B.Braun"
},
"references": [
{
"url": "https://www.bbraun.com/productsecurity"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Field Service Information FSI 14-25 \u201cOnlineSuite AP3.0 - Security Fix\u201d provides a patch to these issues.\n\n\u003cbr\u003e"
}
],
"value": "Field Service Information FSI 14-25 \u201cOnlineSuite AP3.0 - Security Fix\u201d provides a patch to these issues."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Improper Neutralization of Special Elements in OnlineSuite",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "653264ec-f98b-4e8f-b8b4-540a01b7657d",
"assignerShortName": "B.Braun",
"cveId": "CVE-2025-3322",
"datePublished": "2025-06-06T08:13:12.028Z",
"dateReserved": "2025-04-05T19:02:30.304Z",
"dateUpdated": "2025-06-06T17:29:30.972Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3321 (GCVE-0-2025-3321)
Vulnerability from cvelistv5 – Published: 2025-06-06 08:12 – Updated: 2025-06-06 18:25
VLAI?
Summary
A predefined administrative account is not documented and cannot
be deactivated. This account cannot be misused from the network, only by local
users on the server.
Severity ?
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B. Braun Melsungen AG | OnlineSuite |
Affected:
3.0
(custom)
|
Credits
Fabian Weber (CODE WHITE GmbH)
Dr. Florian Hauser (CODE WHITE GmbH)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3321",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-06T17:42:18.841236Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-06T18:25:54.094Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "OnlineSuite",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"status": "affected",
"version": "3.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Fabian Weber (CODE WHITE GmbH)"
},
{
"lang": "en",
"type": "reporter",
"value": "Dr. Florian Hauser (CODE WHITE GmbH)"
}
],
"datePublic": "2025-06-06T07:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\u003c/p\u003e\u003cp\u003eA predefined administrative account is not documented and cannot\nbe deactivated. This account cannot be misused from the network, only by local\nusers on the server.\u003c/p\u003e\n\n\n\n\n\n\u003cp\u003e\u003c/p\u003e"
}
],
"value": "A predefined administrative account is not documented and cannot\nbe deactivated. This account cannot be misused from the network, only by local\nusers on the server."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-06T08:12:46.971Z",
"orgId": "653264ec-f98b-4e8f-b8b4-540a01b7657d",
"shortName": "B.Braun"
},
"references": [
{
"url": "https://www.bbraun.com/productsecurity"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Field Service Information FSI 14-25 \u201cOnlineSuite AP3.0 - Security Fix\u201d provides a patch to these issues."
}
],
"value": "Field Service Information FSI 14-25 \u201cOnlineSuite AP3.0 - Security Fix\u201d provides a patch to these issues."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Use of Hard-coded Credentials in OnlineSuite",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "653264ec-f98b-4e8f-b8b4-540a01b7657d",
"assignerShortName": "B.Braun",
"cveId": "CVE-2025-3321",
"datePublished": "2025-06-06T08:12:46.971Z",
"dateReserved": "2025-04-05T19:01:47.895Z",
"dateUpdated": "2025-06-06T18:25:54.094Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25168 (GCVE-0-2020-25168)
Vulnerability from cvelistv5 – Published: 2022-04-14 20:06 – Updated: 2025-04-16 16:29
VLAI?
Summary
Hard-coded credentials in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enable attackers with command line access to access the device’s Wi-Fi module.
Severity ?
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| B. Braun Melsungen AG | SpaceCom |
Affected:
unspecified , ≤ U61
(custom)
Affected: unspecified , ≤ L81 (custom) |
||||||||||||
|
||||||||||||||
Credits
Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices).
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:10.000Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-25168",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:54:09.627996Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:29:29.444Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SpaceCom",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Battery pack with Wi-Fi",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Data module compactplus",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"status": "affected",
"version": "A10"
},
{
"status": "affected",
"version": "A11"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"descriptions": [
{
"lang": "en",
"value": "Hard-coded credentials in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enable attackers with command line access to access the device\u2019s Wi-Fi module."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798: Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-14T20:06:00.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"solutions": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus",
"workarounds": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-25168",
"STATE": "PUBLIC",
"TITLE": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SpaceCom",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Battery pack with Wi-Fi",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Data module compactplus",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "A10"
},
{
"version_affected": "=",
"version_value": "A11"
}
]
}
}
]
},
"vendor_name": "B. Braun Melsungen AG"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Hard-coded credentials in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enable attackers with command line access to access the device\u2019s Wi-Fi module."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-798: Use of Hard-coded Credentials"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02",
"refsource": "CONFIRM",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"name": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html",
"refsource": "CONFIRM",
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25168",
"datePublished": "2022-04-14T20:06:00.000Z",
"dateReserved": "2020-09-04T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:29:29.444Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25164 (GCVE-0-2020-25164)
Vulnerability from cvelistv5 – Published: 2022-04-14 20:06 – Updated: 2025-04-16 16:29
VLAI?
Summary
A vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to recover user credentials of the administrative interface.
Severity ?
6.5 (Medium)
CWE
- CWE-759 - Use of a One-Way Hash without a Salt
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| B. Braun Melsungen AG | SpaceCom |
Affected:
unspecified , ≤ U61
(custom)
Affected: unspecified , ≤ L81 (custom) |
||||||||||||
|
||||||||||||||
Credits
Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices).
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:09.576Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-25164",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:54:15.208760Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:29:36.723Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SpaceCom",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Battery pack with Wi-Fi",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Data module compactplus",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"status": "affected",
"version": "A10"
},
{
"status": "affected",
"version": "A11"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to recover user credentials of the administrative interface."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-759",
"description": "CWE-759: Use of a One-Way Hash without a Salt",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-14T20:06:00.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"solutions": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus",
"workarounds": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-25164",
"STATE": "PUBLIC",
"TITLE": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SpaceCom",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Battery pack with Wi-Fi",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Data module compactplus",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "A10"
},
{
"version_affected": "=",
"version_value": "A11"
}
]
}
}
]
},
"vendor_name": "B. Braun Melsungen AG"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to recover user credentials of the administrative interface."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-759: Use of a One-Way Hash without a Salt"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02",
"refsource": "CONFIRM",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"name": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html",
"refsource": "CONFIRM",
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25164",
"datePublished": "2022-04-14T20:06:00.000Z",
"dateReserved": "2020-09-04T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:29:36.723Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25166 (GCVE-0-2020-25166)
Vulnerability from cvelistv5 – Published: 2022-04-14 20:05 – Updated: 2025-04-16 16:29
VLAI?
Summary
An improper verification of the cryptographic signature of firmware updates of the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to generate valid firmware updates with arbitrary content that can be used to tamper with devices.
Severity ?
7.6 (High)
CWE
- CWE-347 - Improper Verification of Cryptographic Signature
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| B. Braun Melsungen AG | SpaceCom |
Affected:
unspecified , ≤ U61
(custom)
Affected: unspecified , ≤ L81 (custom) |
||||||||||||
|
||||||||||||||
Credits
Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices).
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:10.204Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-25166",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:54:19.378844Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:29:44.744Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SpaceCom",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Battery pack with Wi-Fi",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Data module compactplus",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"status": "affected",
"version": "A10"
},
{
"status": "affected",
"version": "A11"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"descriptions": [
{
"lang": "en",
"value": "An improper verification of the cryptographic signature of firmware updates of the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to generate valid firmware updates with arbitrary content that can be used to tamper with devices."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-347",
"description": "CWE-347: Improper Verification of Cryptographic Signature",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-14T20:05:59.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"solutions": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus",
"workarounds": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-25166",
"STATE": "PUBLIC",
"TITLE": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SpaceCom",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Battery pack with Wi-Fi",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Data module compactplus",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "A10"
},
{
"version_affected": "=",
"version_value": "A11"
}
]
}
}
]
},
"vendor_name": "B. Braun Melsungen AG"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An improper verification of the cryptographic signature of firmware updates of the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to generate valid firmware updates with arbitrary content that can be used to tamper with devices."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-347: Improper Verification of Cryptographic Signature"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02",
"refsource": "CONFIRM",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"name": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html",
"refsource": "CONFIRM",
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25166",
"datePublished": "2022-04-14T20:05:59.000Z",
"dateReserved": "2020-09-04T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:29:44.744Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25154 (GCVE-0-2020-25154)
Vulnerability from cvelistv5 – Published: 2022-04-14 20:05 – Updated: 2025-04-16 16:29
VLAI?
Summary
An open redirect vulnerability in the administrative interface of the B. Braun Melsungen AG SpaceCom device Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to redirect users to malicious websites.
Severity ?
5.4 (Medium)
CWE
- CWE-601 - Open Redirect
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| B. Braun Melsungen AG | SpaceCom |
Affected:
unspecified , ≤ U61
(custom)
Affected: unspecified , ≤ L81 (custom) |
||||||||||||
|
||||||||||||||
Credits
Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices).
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:10.179Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-25154",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:54:23.787363Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:29:52.798Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SpaceCom",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Battery pack with Wi-Fi",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Data module compactplus",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"status": "affected",
"version": "A10"
},
{
"status": "affected",
"version": "A11"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"descriptions": [
{
"lang": "en",
"value": "An open redirect vulnerability in the administrative interface of the B. Braun Melsungen AG SpaceCom device Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to redirect users to malicious websites."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-601",
"description": "CWE-601: Open Redirect",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-14T20:05:58.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"solutions": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus",
"workarounds": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-25154",
"STATE": "PUBLIC",
"TITLE": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SpaceCom",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Battery pack with Wi-Fi",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Data module compactplus",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "A10"
},
{
"version_affected": "=",
"version_value": "A11"
}
]
}
}
]
},
"vendor_name": "B. Braun Melsungen AG"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An open redirect vulnerability in the administrative interface of the B. Braun Melsungen AG SpaceCom device Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to redirect users to malicious websites."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-601: Open Redirect"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02",
"refsource": "CONFIRM",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"name": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html",
"refsource": "CONFIRM",
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25154",
"datePublished": "2022-04-14T20:05:58.000Z",
"dateReserved": "2020-09-04T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:29:52.798Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25162 (GCVE-0-2020-25162)
Vulnerability from cvelistv5 – Published: 2022-04-14 20:05 – Updated: 2025-04-16 16:29
VLAI?
Summary
A XPath injection vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows unauthenticated remote attackers to access sensitive information and escalate privileges.
Severity ?
7.5 (High)
CWE
- CWE-643 - XPath Injection
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| B. Braun Melsungen AG | SpaceCom |
Affected:
unspecified , ≤ U61
(custom)
Affected: unspecified , ≤ L81 (custom) |
||||||||||||
|
||||||||||||||
Credits
Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices).
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:10.163Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-25162",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:57:38.755895Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:29:59.860Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SpaceCom",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Battery pack with Wi-Fi",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Data module compactplus",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"status": "affected",
"version": "A10"
},
{
"status": "affected",
"version": "A11"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"descriptions": [
{
"lang": "en",
"value": "A XPath injection vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows unauthenticated remote attackers to access sensitive information and escalate privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-643",
"description": "CWE-643: XPath Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-14T20:05:57.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"solutions": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus",
"workarounds": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-25162",
"STATE": "PUBLIC",
"TITLE": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SpaceCom",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Battery pack with Wi-Fi",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Data module compactplus",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "A10"
},
{
"version_affected": "=",
"version_value": "A11"
}
]
}
}
]
},
"vendor_name": "B. Braun Melsungen AG"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A XPath injection vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows unauthenticated remote attackers to access sensitive information and escalate privileges."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-643: XPath Injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02",
"refsource": "CONFIRM",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"name": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html",
"refsource": "CONFIRM",
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25162",
"datePublished": "2022-04-14T20:05:57.000Z",
"dateReserved": "2020-09-04T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:29:59.860Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25158 (GCVE-0-2020-25158)
Vulnerability from cvelistv5 – Published: 2022-04-14 20:05 – Updated: 2025-04-16 16:30
VLAI?
Summary
A reflected cross-site scripting (XSS) vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to inject arbitrary web script or HTML into various locations.
Severity ?
7.6 (High)
CWE
- CWE-79 - Cross-site Scripting
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| B. Braun Melsungen AG | SpaceCom |
Affected:
unspecified , ≤ U61
(custom)
Affected: unspecified , ≤ L81 (custom) |
||||||||||||
|
||||||||||||||
Credits
Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices).
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:10.212Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-25158",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:54:28.036554Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:30:09.180Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SpaceCom",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Battery pack with Wi-Fi",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Data module compactplus",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"status": "affected",
"version": "A10"
},
{
"status": "affected",
"version": "A11"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"descriptions": [
{
"lang": "en",
"value": "A reflected cross-site scripting (XSS) vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to inject arbitrary web script or HTML into various locations."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Cross-site Scripting",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-14T20:05:56.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"solutions": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus",
"workarounds": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-25158",
"STATE": "PUBLIC",
"TITLE": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SpaceCom",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Battery pack with Wi-Fi",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Data module compactplus",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "A10"
},
{
"version_affected": "=",
"version_value": "A11"
}
]
}
}
]
},
"vendor_name": "B. Braun Melsungen AG"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A reflected cross-site scripting (XSS) vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to inject arbitrary web script or HTML into various locations."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79: Cross-site Scripting"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02",
"refsource": "CONFIRM",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"name": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html",
"refsource": "CONFIRM",
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25158",
"datePublished": "2022-04-14T20:05:56.000Z",
"dateReserved": "2020-09-04T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:30:09.180Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25152 (GCVE-0-2020-25152)
Vulnerability from cvelistv5 – Published: 2022-04-14 20:05 – Updated: 2025-04-16 16:30
VLAI?
Summary
A session fixation vulnerability in the B. Braun Melsungen AG SpaceCom administrative interface Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to hijack web sessions and escalate privileges.
Severity ?
6.5 (Medium)
CWE
- CWE-384 - Session Fixation
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| B. Braun Melsungen AG | SpaceCom |
Affected:
unspecified , ≤ U61
(custom)
Affected: unspecified , ≤ L81 (custom) |
||||||||||||
|
||||||||||||||
Credits
Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices).
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:09.803Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-25152",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:54:34.665213Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:30:24.443Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SpaceCom",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Battery pack with Wi-Fi",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Data module compactplus",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"status": "affected",
"version": "A10"
},
{
"status": "affected",
"version": "A11"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"descriptions": [
{
"lang": "en",
"value": "A session fixation vulnerability in the B. Braun Melsungen AG SpaceCom administrative interface Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to hijack web sessions and escalate privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-384",
"description": "CWE-384: Session Fixation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-14T20:05:55.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"solutions": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus",
"workarounds": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-25152",
"STATE": "PUBLIC",
"TITLE": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SpaceCom",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Battery pack with Wi-Fi",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Data module compactplus",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "A10"
},
{
"version_affected": "=",
"version_value": "A11"
}
]
}
}
]
},
"vendor_name": "B. Braun Melsungen AG"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A session fixation vulnerability in the B. Braun Melsungen AG SpaceCom administrative interface Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to hijack web sessions and escalate privileges."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-384: Session Fixation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02",
"refsource": "CONFIRM",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"name": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html",
"refsource": "CONFIRM",
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25152",
"datePublished": "2022-04-14T20:05:55.000Z",
"dateReserved": "2020-09-04T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:30:24.443Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25160 (GCVE-0-2020-25160)
Vulnerability from cvelistv5 – Published: 2022-04-14 20:05 – Updated: 2025-04-16 16:30
VLAI?
Summary
Improper access controls in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enables attackers to extract and tamper with the devices network configuration.
Severity ?
6.8 (Medium)
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| B. Braun Melsungen AG | SpaceCom |
Affected:
unspecified , ≤ U61
(custom)
Affected: unspecified , ≤ L81 (custom) |
||||||||||||
|
||||||||||||||
Credits
Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices).
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:09.469Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-25160",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:54:31.099580Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:30:17.021Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SpaceCom",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Battery pack with Wi-Fi",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Data module compactplus",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"status": "affected",
"version": "A10"
},
{
"status": "affected",
"version": "A11"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper access controls in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enables attackers to extract and tamper with the devices network configuration."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-14T20:05:55.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"solutions": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus",
"workarounds": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-25160",
"STATE": "PUBLIC",
"TITLE": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SpaceCom",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Battery pack with Wi-Fi",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Data module compactplus",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "A10"
},
{
"version_affected": "=",
"version_value": "A11"
}
]
}
}
]
},
"vendor_name": "B. Braun Melsungen AG"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper access controls in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enables attackers to extract and tamper with the devices network configuration."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284: Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02",
"refsource": "CONFIRM",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"name": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html",
"refsource": "CONFIRM",
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25160",
"datePublished": "2022-04-14T20:05:55.000Z",
"dateReserved": "2020-09-04T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:30:17.021Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25156 (GCVE-0-2020-25156)
Vulnerability from cvelistv5 – Published: 2022-04-14 20:05 – Updated: 2025-04-16 17:55
VLAI?
Summary
Active debug code in the B. Braun Melsungen AG SpaceCom Version L8/U61, and the Data module compactplus Versions A10 and A11 and earlier enables attackers in possession of cryptographic material to access the device as root.
Severity ?
7.2 (High)
CWE
- CWE-489 - Active Debug Code
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| B. Braun Melsungen AG | SpaceCom |
Affected:
unspecified , ≤ U61
(custom)
Affected: unspecified , ≤ L81 (custom) |
||||||||||||
|
||||||||||||||
Credits
Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices).
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:09.778Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-25156",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T17:29:43.063614Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T17:55:34.722Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SpaceCom",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Battery pack with Wi-Fi",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Data module compactplus",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"status": "affected",
"version": "A10"
},
{
"status": "affected",
"version": "A11"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"descriptions": [
{
"lang": "en",
"value": "Active debug code in the B. Braun Melsungen AG SpaceCom Version L8/U61, and the Data module compactplus Versions A10 and A11 and earlier enables attackers in possession of cryptographic material to access the device as root."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-489",
"description": "CWE-489: Active Debug Code",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-14T20:05:53.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"solutions": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus",
"workarounds": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-25156",
"STATE": "PUBLIC",
"TITLE": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SpaceCom",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Battery pack with Wi-Fi",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Data module compactplus",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "A10"
},
{
"version_affected": "=",
"version_value": "A11"
}
]
}
}
]
},
"vendor_name": "B. Braun Melsungen AG"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Active debug code in the B. Braun Melsungen AG SpaceCom Version L8/U61, and the Data module compactplus Versions A10 and A11 and earlier enables attackers in possession of cryptographic material to access the device as root."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-489: Active Debug Code"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02",
"refsource": "CONFIRM",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"name": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html",
"refsource": "CONFIRM",
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25156",
"datePublished": "2022-04-14T20:05:53.000Z",
"dateReserved": "2020-09-04T00:00:00.000Z",
"dateUpdated": "2025-04-16T17:55:34.722Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-16238 (GCVE-0-2020-16238)
Vulnerability from cvelistv5 – Published: 2022-04-14 20:05 – Updated: 2025-04-16 17:55
VLAI?
Summary
A vulnerability in the configuration import mechanism of the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers with command line access to the underlying Linux system to escalate privileges to the root user.
Severity ?
6.7 (Medium)
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| B. Braun Melsungen AG | SpaceCom |
Affected:
unspecified , ≤ U61
(custom)
Affected: unspecified , ≤ L81 (custom) |
||||||||||||
|
||||||||||||||
Credits
Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices).
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:37:53.954Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-16238",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T17:29:45.935171Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T17:55:42.177Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SpaceCom",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Battery pack with Wi-Fi",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Data module compactplus",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"status": "affected",
"version": "A10"
},
{
"status": "affected",
"version": "A11"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the configuration import mechanism of the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers with command line access to the underlying Linux system to escalate privileges to the root user."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269: Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-14T20:05:53.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"solutions": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus",
"workarounds": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-16238",
"STATE": "PUBLIC",
"TITLE": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SpaceCom",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Battery pack with Wi-Fi",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Data module compactplus",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "A10"
},
{
"version_affected": "=",
"version_value": "A11"
}
]
}
}
]
},
"vendor_name": "B. Braun Melsungen AG"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the configuration import mechanism of the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers with command line access to the underlying Linux system to escalate privileges to the root user."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-269: Improper Privilege Management"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02",
"refsource": "CONFIRM",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"name": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html",
"refsource": "CONFIRM",
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-16238",
"datePublished": "2022-04-14T20:05:53.000Z",
"dateReserved": "2020-07-31T00:00:00.000Z",
"dateUpdated": "2025-04-16T17:55:42.177Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25150 (GCVE-0-2020-25150)
Vulnerability from cvelistv5 – Published: 2022-04-14 20:05 – Updated: 2025-04-16 16:30
VLAI?
Summary
A relative path traversal attack in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers with service user privileges to upload arbitrary files. By uploading a specially crafted tar file an attacker can execute arbitrary commands.
Severity ?
7.6 (High)
CWE
- CWE-23 - Relative Path Traversal
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| B. Braun Melsungen AG | SpaceCom |
Affected:
unspecified , ≤ U61
(custom)
Affected: unspecified , ≤ L81 (custom) |
||||||||||||
|
||||||||||||||
Credits
Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices).
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:09.495Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-25150",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:54:38.970393Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:30:32.103Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SpaceCom",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Battery pack with Wi-Fi",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "U61",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "L81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Data module compactplus",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"status": "affected",
"version": "A10"
},
{
"status": "affected",
"version": "A11"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"descriptions": [
{
"lang": "en",
"value": "A relative path traversal attack in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers with service user privileges to upload arbitrary files. By uploading a specially crafted tar file an attacker can execute arbitrary commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-23",
"description": "CWE-23: Relative Path Traversal",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-14T20:05:52.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"solutions": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus",
"workarounds": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-25150",
"STATE": "PUBLIC",
"TITLE": "B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SpaceCom",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Battery pack with Wi-Fi",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "U61"
},
{
"version_affected": "\u003c=",
"version_value": "L81"
}
]
}
},
{
"product_name": "Data module compactplus",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "A10"
},
{
"version_affected": "=",
"version_value": "A11"
}
]
}
}
]
},
"vendor_name": "B. Braun Melsungen AG"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Julian Suleder, Nils Emmerich, and Birk Kauer of ERNW Research GmbH; Dr. Oliver Matula of ERNW Enno Rey Netzwerke GmbH, reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices)."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A relative path traversal attack in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers with service user privileges to upload arbitrary files. By uploading a specially crafted tar file an attacker can execute arbitrary commands."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-23: Relative Path Traversal"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02",
"refsource": "CONFIRM",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-20-296-02"
},
{
"name": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html",
"refsource": "CONFIRM",
"url": "https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "B. Braun recommends applying updates:\n\n SpaceCom: Version U62 or later (United States), L82 or later (outside the United States)\n Battery Pack SP with Wi-Fi: Version U62 or later (United States), L82 or later (outside the United States)\n Data module compactplus: Version A12 or later\n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "As a general security measure, B. Braun recommends protecting the network with appropriate mechanisms:\n\n Ensure the devices are not accessible directly from the Internet.\n Use a firewall and isolate the medical devices from the business network. \n\nPlease contact your local B. Braun organization to request further help. For more information please see the B. Braun Security Advisory. https://www.bbraun.com/en/products-and-therapies/services/b-braun-vulnerability-disclosure-policy/security-advisory.html"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25150",
"datePublished": "2022-04-14T20:05:52.000Z",
"dateReserved": "2020-09-04T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:30:32.103Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25172 (GCVE-0-2020-25172)
Vulnerability from cvelistv5 – Published: 2020-11-06 16:09 – Updated: 2024-09-16 18:39
VLAI?
Summary
A relative path traversal attack in the B. Braun OnlineSuite Version AP 3.0 and earlier allows unauthenticated attackers to upload or download arbitrary files.
Severity ?
No CVSS data available.
CWE
- CWE-23 - RELATIVE PATH TRAVERSAL CWE-23
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B. Braun Melsungen AG | OnlineSuite |
Affected:
AP , ≤ 3.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:10.164Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-296-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "OnlineSuite",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "3.0",
"status": "affected",
"version": "AP",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-10-22T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A relative path traversal attack in the B. Braun OnlineSuite Version AP 3.0 and earlier allows unauthenticated attackers to upload or download arbitrary files."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-23",
"description": "RELATIVE PATH TRAVERSAL CWE-23",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-06T16:09:16",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-296-01"
}
],
"source": {
"advisory": "ICSMA-20-296-01",
"discovery": "UNKNOWN"
},
"title": "B. Braun OnlineSuite",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2020-10-22T15:00:00.000Z",
"ID": "CVE-2020-25172",
"STATE": "PUBLIC",
"TITLE": "B. Braun OnlineSuite"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "OnlineSuite",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "AP",
"version_value": "3.0"
}
]
}
}
]
},
"vendor_name": "B. Braun Melsungen AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A relative path traversal attack in the B. Braun OnlineSuite Version AP 3.0 and earlier allows unauthenticated attackers to upload or download arbitrary files."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "RELATIVE PATH TRAVERSAL CWE-23"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsma-20-296-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-296-01"
}
]
},
"source": {
"advisory": "ICSMA-20-296-01",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25172",
"datePublished": "2020-11-06T16:09:16.397700Z",
"dateReserved": "2020-09-04T00:00:00",
"dateUpdated": "2024-09-16T18:39:05.515Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25174 (GCVE-0-2020-25174)
Vulnerability from cvelistv5 – Published: 2020-11-06 16:08 – Updated: 2024-09-17 00:16
VLAI?
Summary
A DLL hijacking vulnerability in the B. Braun OnlineSuite Version AP 3.0 and earlier allows local attackers to execute code on the system as a high privileged user.
Severity ?
No CVSS data available.
CWE
- CWE-427 - UNCONTROLLED SEARCH PATH ELEMENT CWE-427
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B. Braun Melsungen AG | OnlineSuite |
Affected:
AP , ≤ 3.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:10.187Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-296-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "OnlineSuite",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "3.0",
"status": "affected",
"version": "AP",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-10-22T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A DLL hijacking vulnerability in the B. Braun OnlineSuite Version AP 3.0 and earlier allows local attackers to execute code on the system as a high privileged user."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "UNCONTROLLED SEARCH PATH ELEMENT CWE-427",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-06T16:08:41",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-296-01"
}
],
"source": {
"advisory": "ICSMA-20-296-01",
"discovery": "UNKNOWN"
},
"title": "B. Braun OnlineSuite",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2020-10-22T15:00:00.000Z",
"ID": "CVE-2020-25174",
"STATE": "PUBLIC",
"TITLE": "B. Braun OnlineSuite"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "OnlineSuite",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "AP",
"version_value": "3.0"
}
]
}
}
]
},
"vendor_name": "B. Braun Melsungen AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A DLL hijacking vulnerability in the B. Braun OnlineSuite Version AP 3.0 and earlier allows local attackers to execute code on the system as a high privileged user."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "UNCONTROLLED SEARCH PATH ELEMENT CWE-427"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsma-20-296-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-296-01"
}
]
},
"source": {
"advisory": "ICSMA-20-296-01",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25174",
"datePublished": "2020-11-06T16:08:41.727185Z",
"dateReserved": "2020-09-04T00:00:00",
"dateUpdated": "2024-09-17T00:16:15.836Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25170 (GCVE-0-2020-25170)
Vulnerability from cvelistv5 – Published: 2020-11-06 16:08 – Updated: 2024-09-17 00:56
VLAI?
Summary
An Excel Macro Injection vulnerability exists in the export feature in the B. Braun OnlineSuite Version AP 3.0 and earlier via multiple input fields that are mishandled in an Excel export.
Severity ?
No CVSS data available.
CWE
- CWE-1236 - IMPROPER NEUTRALIZATION OF FORMULA ELEMENTS IN A CSV FILE CWE-1236
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B. Braun Melsungen AG | OnlineSuite |
Affected:
AP , ≤ 3.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:09.606Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-296-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "OnlineSuite",
"vendor": "B. Braun Melsungen AG",
"versions": [
{
"lessThanOrEqual": "3.0",
"status": "affected",
"version": "AP",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-10-22T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "An Excel Macro Injection vulnerability exists in the export feature in the B. Braun OnlineSuite Version AP 3.0 and earlier via multiple input fields that are mishandled in an Excel export."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1236",
"description": "IMPROPER NEUTRALIZATION OF FORMULA ELEMENTS IN A CSV FILE CWE-1236",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-06T16:08:07",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-296-01"
}
],
"source": {
"advisory": "ICSMA-20-296-01",
"discovery": "UNKNOWN"
},
"title": "B. Braun OnlineSuite",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2020-10-22T15:00:00.000Z",
"ID": "CVE-2020-25170",
"STATE": "PUBLIC",
"TITLE": "B. Braun OnlineSuite"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "OnlineSuite",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "AP",
"version_value": "3.0"
}
]
}
}
]
},
"vendor_name": "B. Braun Melsungen AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An Excel Macro Injection vulnerability exists in the export feature in the B. Braun OnlineSuite Version AP 3.0 and earlier via multiple input fields that are mishandled in an Excel export."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER NEUTRALIZATION OF FORMULA ELEMENTS IN A CSV FILE CWE-1236"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsma-20-296-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-296-01"
}
]
},
"source": {
"advisory": "ICSMA-20-296-01",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25170",
"datePublished": "2020-11-06T16:08:07.525834Z",
"dateReserved": "2020-09-04T00:00:00",
"dateUpdated": "2024-09-17T00:56:57.848Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",