CVE-2021-22272 (GCVE-0-2021-22272)

Vulnerability from cvelistv5 – Published: 2021-09-27 13:40 – Updated: 2024-09-16 19:30
VLAI?
Summary
The vulnerability origins in the commissioning process where an attacker of the ControlTouch can enter a serial number in a specific way to transfer the device virtually into her/his my.busch-jaeger.de or mybuildings.abb.com profile. A successful attacker can observe and control a ControlTouch remotely under very specific circumstances. The issue is fixed in the cloud side of the system. No firmware update is needed for customer products. If a user wants to understand if (s)he is affected, please read the advisory. This issue affects: ABB and Busch-Jaeger, ControlTouch
CWE
Assigner
ABB
References
Impacted products
Vendor Product Version
ABB mybuildings.abb.com Affected: 2021-05-03 , < 2021-05-03 (custom)
Create a notification for this product.
    Busch-Jaeger my.busch-jaeger.de Affected: 2021-05-03 , < 2021-05-03 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:37:18.488Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107992A3688\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "virtual"
          ],
          "product": "mybuildings.abb.com",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "2021-05-03",
              "status": "affected",
              "version": "2021-05-03",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "virtual"
          ],
          "product": "my.busch-jaeger.de",
          "vendor": "Busch-Jaeger",
          "versions": [
            {
              "lessThan": "2021-05-03",
              "status": "affected",
              "version": "2021-05-03",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-06-30T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The vulnerability origins in the commissioning process where an attacker of the ControlTouch can enter a serial number in a specific way to transfer the device virtually into her/his my.busch-jaeger.de or mybuildings.abb.com profile. A successful attacker can observe and control a ControlTouch remotely under very specific circumstances. The issue is fixed in the cloud side of the system. No firmware update is needed for customer products. If a user wants to understand if (s)he is affected, please read the advisory. This issue affects: ABB and Busch-Jaeger, ControlTouch"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-27T13:40:32",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107992A3688\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ControlTouch Cloud Service vulnerability: Serial Number can be misused during commissioning phase.",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@ch.abb.com",
          "DATE_PUBLIC": "2021-06-30T07:56:00.000Z",
          "ID": "CVE-2021-22272",
          "STATE": "PUBLIC",
          "TITLE": "ControlTouch Cloud Service vulnerability: Serial Number can be misused during commissioning phase."
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "mybuildings.abb.com",
                      "version": {
                        "version_data": [
                          {
                            "platform": "virtual",
                            "version_affected": "\u003c",
                            "version_name": "2021-05-03",
                            "version_value": "2021-05-03"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ABB"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "my.busch-jaeger.de",
                      "version": {
                        "version_data": [
                          {
                            "platform": "virtual",
                            "version_affected": "\u003c",
                            "version_name": "2021-05-03",
                            "version_value": "2021-05-03"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Busch-Jaeger"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The vulnerability origins in the commissioning process where an attacker of the ControlTouch can enter a serial number in a specific way to transfer the device virtually into her/his my.busch-jaeger.de or mybuildings.abb.com profile. A successful attacker can observe and control a ControlTouch remotely under very specific circumstances. The issue is fixed in the cloud side of the system. No firmware update is needed for customer products. If a user wants to understand if (s)he is affected, please read the advisory. This issue affects: ABB and Busch-Jaeger, ControlTouch"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200 Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107992A3688\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "MISC",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107992A3688\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2021-22272",
    "datePublished": "2021-09-27T13:40:32.018316Z",
    "dateReserved": "2021-01-05T00:00:00",
    "dateUpdated": "2024-09-16T19:30:00.538Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-22276 (GCVE-0-2021-22276)

Vulnerability from cvelistv5 – Published: 2021-09-23 15:20 – Updated: 2024-09-16 20:58
VLAI?
Summary
The vulnerability allows a successful attacker to bypass the integrity check of FW uploaded to the free@home System Access Point.
CWE
Assigner
ABB
References
Impacted products
Vendor Product Version
ABB System Access Point Affected: 2CKA006200A0156 , ≤ 2.6.3 (custom)
Affected: 2CKA006200A0155 , ≤ 2.6.3 (custom)
Affected: 2CKA006220A0240 , ≤ 2.6.3 (custom)
Affected: 2CKA006220A0136 , ≤ 2.6.3 (custom)
Affected: 2CKA006200A0130 , ≤ 2.6.3 (custom)
Affected: 2CKA006200A0105 , ≤ 2.6.3 (custom)
Affected: 2CKA006200A0071 , ≤ 2.6.3 (custom)
Create a notification for this product.
    Busch-Jaeger System Access Point Affected: 2CKA006220A0031 , ≤ 2.6.3 (custom)
Affected: 2CKA006200A0154 , ≤ 2.6.3 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:37:18.536Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107992A6475\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "System Access Point",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "2.6.3",
              "status": "affected",
              "version": "2CKA006200A0156",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "2.6.3",
              "status": "affected",
              "version": "2CKA006200A0155",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "2.6.3",
              "status": "affected",
              "version": "2CKA006220A0240",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "2.6.3",
              "status": "affected",
              "version": "2CKA006220A0136",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "2.6.3",
              "status": "affected",
              "version": "2CKA006200A0130",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "2.6.3",
              "status": "affected",
              "version": "2CKA006200A0105",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "2.6.3",
              "status": "affected",
              "version": "2CKA006200A0071",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "System Access Point",
          "vendor": "Busch-Jaeger",
          "versions": [
            {
              "lessThanOrEqual": "2.6.3",
              "status": "affected",
              "version": "2CKA006220A0031",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "2.6.3",
              "status": "affected",
              "version": "2CKA006200A0154",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-06-30T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The vulnerability allows a successful attacker to bypass the integrity check of FW uploaded to the free@home System Access Point."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-23T15:20:42",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107992A6475\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "free@home System Access Point FW integrity check can be bypassed.",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@ch.abb.com",
          "DATE_PUBLIC": "2021-06-30T07:56:00.000Z",
          "ID": "CVE-2021-22276",
          "STATE": "PUBLIC",
          "TITLE": "free@home System Access Point FW integrity check can be bypassed."
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "System Access Point",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2CKA006200A0156",
                            "version_value": "2.6.3"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2CKA006200A0155",
                            "version_value": "2.6.3"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2CKA006220A0240",
                            "version_value": "2.6.3"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2CKA006220A0136",
                            "version_value": "2.6.3"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2CKA006200A0130",
                            "version_value": "2.6.3"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2CKA006200A0105",
                            "version_value": "2.6.3"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2CKA006200A0071",
                            "version_value": "2.6.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ABB"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "System Access Point",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2CKA006220A0031",
                            "version_value": "2.6.3"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2CKA006200A0154",
                            "version_value": "2.6.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Busch-Jaeger"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The vulnerability allows a successful attacker to bypass the integrity check of FW uploaded to the free@home System Access Point."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200 Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107992A6475\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "MISC",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107992A6475\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2021-22276",
    "datePublished": "2021-09-23T15:20:42.229576Z",
    "dateReserved": "2021-01-05T00:00:00",
    "dateUpdated": "2024-09-16T20:58:27.861Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-19107 (GCVE-0-2019-19107)

Vulnerability from cvelistv5 – Published: 2020-04-22 14:38 – Updated: 2024-08-05 02:09
VLAI?
Summary
The Configuration pages in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway for user profiles and services transfer the password in plaintext (although hidden when displayed).
CWE
  • CWE-264 - Permissions, Privileges, and Access Controls
Assigner
ABB
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T02:09:39.410Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107680A3921\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "TG/S 3.2 Telephone Gateway",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "2CDG 110 135 R0011"
            }
          ]
        },
        {
          "product": "6186/11 Telefon-Gateway ",
          "vendor": "Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "2CKA006136A0187"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Configuration pages in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway for user profiles and services transfer the password in plaintext (although hidden when displayed)."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-264",
              "description": "CWE-264 Permissions, Privileges, and Access Controls",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-22T14:38:59",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107680A3921\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ABB/Busch-Jaeger Telephone Gateway TG/S 3.2 Information Exposure",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@ch.abb.com",
          "ID": "CVE-2019-19107",
          "STATE": "PUBLIC",
          "TITLE": "ABB/Busch-Jaeger Telephone Gateway TG/S 3.2 Information Exposure"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "TG/S 3.2 Telephone Gateway",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "2CDG 110 135 R0011"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ABB"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "6186/11 Telefon-Gateway ",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "2CKA006136A0187"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Busch-Jaeger"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Configuration pages in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway for user profiles and services transfer the password in plaintext (although hidden when displayed)."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-264 Permissions, Privileges, and Access Controls"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107680A3921\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "MISC",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107680A3921\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2019-19107",
    "datePublished": "2020-04-22T14:38:59",
    "dateReserved": "2019-11-18T00:00:00",
    "dateUpdated": "2024-08-05T02:09:39.410Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-19106 (GCVE-0-2019-19106)

Vulnerability from cvelistv5 – Published: 2020-04-22 14:37 – Updated: 2024-08-05 02:09
VLAI?
Summary
Improper implementation of Access Control in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows an unauthorized user to access data marked as restricted, such as viewing or editing user profiles and application settings.
CWE
  • CWE-264 - Permissions, Privileges, and Access Controls
Assigner
ABB
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T02:09:39.361Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107680A3921\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "TG/S 3.2 Telephone Gateway",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "2CDG 110 135 R0011"
            }
          ]
        },
        {
          "product": "6186/11 Telefon-Gateway ",
          "vendor": "Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "2CKA006136A0187"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper implementation of Access Control in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows an unauthorized user to access data marked as restricted, such as viewing or editing user profiles and application settings."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-264",
              "description": "CWE-264 Permissions, Privileges, and Access Controls",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-22T14:37:11",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107680A3921\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ABB/Busch-Jaeger Telephone Gateway TG/S 3.2 Access Control issues",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@ch.abb.com",
          "ID": "CVE-2019-19106",
          "STATE": "PUBLIC",
          "TITLE": "ABB/Busch-Jaeger Telephone Gateway TG/S 3.2 Access Control issues"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "TG/S 3.2 Telephone Gateway",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "2CDG 110 135 R0011"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ABB"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "6186/11 Telefon-Gateway ",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "2CKA006136A0187"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Busch-Jaeger"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper implementation of Access Control in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows an unauthorized user to access data marked as restricted, such as viewing or editing user profiles and application settings."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-264 Permissions, Privileges, and Access Controls"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107680A3921\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "MISC",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107680A3921\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2019-19106",
    "datePublished": "2020-04-22T14:37:11",
    "dateReserved": "2019-11-18T00:00:00",
    "dateUpdated": "2024-08-05T02:09:39.361Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-19105 (GCVE-0-2019-19105)

Vulnerability from cvelistv5 – Published: 2020-04-22 14:35 – Updated: 2024-08-05 02:09
VLAI?
Summary
The backup function in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway saves the current settings and configuration of the application, including credentials of existing user accounts and other configuration's credentials in plaintext.
CWE
  • CWE-256 - Unprotected Storage of Credentials
Assigner
ABB
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T02:09:39.293Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107680A3921\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "TG/S 3.2 Telephone Gateway",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "2CDG 110 135 R0011"
            }
          ]
        },
        {
          "product": "6186/11 Telefon-Gateway ",
          "vendor": "Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "2CKA006136A0187"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The backup function in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway saves the current settings and configuration of the application, including credentials of existing user accounts and other configuration\u0027s credentials in plaintext."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-256",
              "description": "CWE-256 Unprotected Storage of Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-22T14:35:17",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107680A3921\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ABB/Busch-Jaeger Telephone Gateway TG/S 3.2 Plaintext storing of credentials",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@ch.abb.com",
          "ID": "CVE-2019-19105",
          "STATE": "PUBLIC",
          "TITLE": "ABB/Busch-Jaeger Telephone Gateway TG/S 3.2 Plaintext storing of credentials"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "TG/S 3.2 Telephone Gateway",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "2CDG 110 135 R0011"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ABB"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "6186/11 Telefon-Gateway ",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "2CKA006136A0187"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Busch-Jaeger"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The backup function in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway saves the current settings and configuration of the application, including credentials of existing user accounts and other configuration\u0027s credentials in plaintext."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-256 Unprotected Storage of Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107680A3921\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "MISC",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107680A3921\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2019-19105",
    "datePublished": "2020-04-22T14:35:17",
    "dateReserved": "2019-11-18T00:00:00",
    "dateUpdated": "2024-08-05T02:09:39.293Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-19104 (GCVE-0-2019-19104)

Vulnerability from cvelistv5 – Published: 2020-04-22 14:31 – Updated: 2024-08-05 02:09
VLAI?
Summary
The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.
CWE
  • CWE-287 - Improper Authentication
Assigner
ABB
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T02:09:39.458Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107680A3921\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "TG/S 3.2 Telephone Gateway",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "2CDG 110 135 R0011"
            }
          ]
        },
        {
          "product": "6186/11 Telefon-Gateway ",
          "vendor": "Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "2CKA006136A0187"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-22T14:31:55",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107680A3921\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ABB/Busch-Jaeger Telephone Gateway TG/S 3.2 Improper Authentication and Access Control",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@ch.abb.com",
          "ID": "CVE-2019-19104",
          "STATE": "PUBLIC",
          "TITLE": "ABB/Busch-Jaeger Telephone Gateway TG/S 3.2 Improper Authentication and Access Control"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "TG/S 3.2 Telephone Gateway",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "2CDG 110 135 R0011"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ABB"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "6186/11 Telefon-Gateway ",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "2CKA006136A0187"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Busch-Jaeger"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287 Improper Authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107680A3921\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "MISC",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107680A3921\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2019-19104",
    "datePublished": "2020-04-22T14:31:55",
    "dateReserved": "2019-11-18T00:00:00",
    "dateUpdated": "2024-08-05T02:09:39.458Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}