    CVE-2026-2584 (GCVE-0-2026-2584)

    Vulnerability from cvelistv5 – Published: 2026-03-02 09:01 – Updated: 2026-03-02 13:24
    VLAI
    Title
    SQL Injection in Ciser System SL firmware
    Summary
    A critical SQL Injection (SQLi) vulnerability has been identified in the authentication module of the system. An unauthenticated, remote attacker (AV:N/PR:N) can exploit this flaw by sending specially crafted SQL queries through the login interface. Due to low attack complexity (AC:L) and the absence of specific requirements (AT:N), the vulnerability allows for a total compromise of the system's configuration data (VC:H/VI:H). While the availability of the service remains unaffected (VA:N), the breach may lead to a limited exposure of sensitive information regarding subsequent or interconnected systems (SC:L).
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Assigner
    Impacted products
    Vendor Product Version
    Ciser System SL CSIP firmware Affected: 3.0 to 5.1 (fixed)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2584",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-02T13:23:54.693229Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-02T13:24:05.109Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CSIP firmware",
              "vendor": "Ciser System SL",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.0 to 5.1",
                  "versionType": "fixed"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A critical SQL Injection (SQLi) vulnerability has been identified in the authentication module of the system. An unauthenticated, remote attacker (AV:N/PR:N) can exploit this flaw by sending specially crafted SQL queries through the login interface. Due to low attack complexity (AC:L) and the absence of specific requirements (AT:N), the vulnerability allows for a total compromise of the system\u0027s configuration data (VC:H/VI:H). While the availability of the service remains unaffected (VA:N), the breach may lead to a limited exposure of sensitive information regarding subsequent or interconnected systems (SC:L)."
                }
              ],
              "value": "A critical SQL Injection (SQLi) vulnerability has been identified in the authentication module of the system. An unauthenticated, remote attacker (AV:N/PR:N) can exploit this flaw by sending specially crafted SQL queries through the login interface. Due to low attack complexity (AC:L) and the absence of specific requirements (AT:N), the vulnerability allows for a total compromise of the system\u0027s configuration data (VC:H/VI:H). While the availability of the service remains unaffected (VA:N), the breach may lead to a limited exposure of sensitive information regarding subsequent or interconnected systems (SC:L)."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:L/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-02T09:01:12.291Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso/sql-injection-ciser-system-sl-firmware"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe vulnerability has been fixed by the vendor through improved input validation logic and parameterized queries:\u003c/p\u003e\u003cp\u003eIt is recommended to update to firmware version 5.3 or higher. This version mitigates the risk by ensuring that SQL queries are handled securely, effectively neutralizing the injection vector.\u003c/p\u003e"
                }
              ],
              "value": "The vulnerability has been fixed by the vendor through improved input validation logic and parameterized queries:\n\nIt is recommended to update to firmware version 5.3 or higher. This version mitigates the risk by ensuring that SQL queries are handled securely, effectively neutralizing the injection vector."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "SQL Injection in Ciser System SL firmware",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eIf an immediate firmware update is not feasible, network-level controls must be implemented to reduce the attack surface:\u003c/p\u003e\u003cul\u003e\u003cli\u003eAccess Restriction: Limit access to the management or login panel using an Allowlist. All connection attempts from untrusted networks or the public internet must be strictly blocked.\u003c/li\u003e\u003cli\u003eNetwork Segmentation: Isolate the management interface within a dedicated management VLAN, accessible only through a secure corporate VPN.\u003c/li\u003e\u003c/ul\u003e"
                }
              ],
              "value": "If an immediate firmware update is not feasible, network-level controls must be implemented to reduce the attack surface:\n\n  *  Access Restriction: Limit access to the management or login panel using an Allowlist. All connection attempts from untrusted networks or the public internet must be strictly blocked.\n  *  Network Segmentation: Isolate the management interface within a dedicated management VLAN, accessible only through a secure corporate VPN."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2026-2584",
        "datePublished": "2026-03-02T09:01:12.291Z",
        "dateReserved": "2026-02-16T13:17:13.207Z",
        "dateUpdated": "2026-03-02T13:24:05.109Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }