1 vulnerability by CleverControl
CVE-2025-10548 (GCVE-0-2025-10548)
Vulnerability from cvelistv5 – Published: 2025-09-23 06:49 – Updated: 2025-11-03 18:08
VLAI
Title
Missing Certificate Validation in CleverControl Installer Allows Remote Code Execution
Summary
The CleverControl employee monitoring software (v11.5.1041.6) fails to validate TLS server certificates during the installation process. The installer downloads and executes external components using curl.exe --insecure, enabling a man-in-the-middle attacker to deliver malicious files that are executed with SYSTEM privileges. This can lead to full remote code execution with administrative rights. No patch is available as the vendor has been unresponsive. It is assumed that previous versions are also affected, but this is not confirmed.
Severity
6.5 (Medium)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-295 - Improper Certificate Validation
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://r.sec-consult.com/clevercontrol | third-party-advisory |
| http://seclists.org/fulldisclosure/2025/Sep/71 |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| CleverControl | CleverControl employee monitoring software |
Affected:
11.5.1041.6
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-10548",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-23T19:34:25.010051Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-23T19:34:50.357Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T18:08:42.269Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Sep/71"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "CleverControl employee monitoring software",
"vendor": "CleverControl",
"versions": [
{
"status": "affected",
"version": "11.5.1041.6"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Daniel Hirschberger, SEC Consult Vulnerability Lab"
},
{
"lang": "en",
"type": "finder",
"value": "Thorger Jansen, SEC Consult Vulnerability Lab"
},
{
"lang": "en",
"type": "finder",
"value": "Tobias Niemann, SEC Consult Vulnerability Lab"
},
{
"lang": "en",
"type": "finder",
"value": "Marius Renner, SEC Consult Vulnerability Lab"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThe CleverControl employee monitoring software (v11.5.1041.6) fails to validate TLS server certificates during the installation process. The installer downloads and executes external components using \u003ccode\u003ecurl.exe --insecure\u003c/code\u003e, enabling a man-in-the-middle attacker to deliver malicious files that are executed with SYSTEM privileges. This can lead to full remote code execution with administrative rights. No patch is available as the vendor has been unresponsive. It is assumed that previous versions are also affected, but this is not confirmed.\u003c/p\u003e"
}
],
"value": "The CleverControl employee monitoring software (v11.5.1041.6) fails to validate TLS server certificates during the installation process. The installer downloads and executes external components using curl.exe --insecure, enabling a man-in-the-middle attacker to deliver malicious files that are executed with SYSTEM privileges. This can lead to full remote code execution with administrative rights. No patch is available as the vendor has been unresponsive. It is assumed that previous versions are also affected, but this is not confirmed."
}
],
"impacts": [
{
"capecId": "CAPEC-558",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-558 Replace Trusted Executable"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-295",
"description": "CWE-295 Improper Certificate Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-23T06:49:33.659Z",
"orgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
"shortName": "SEC-VLab"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://r.sec-consult.com/clevercontrol"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vendor did not respond to any communication attempts. Therefore, no patch is available at the time of publication."
}
],
"value": "The vendor did not respond to any communication attempts. Therefore, no patch is available at the time of publication."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Missing Certificate Validation in CleverControl Installer Allows Remote Code Execution",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
"assignerShortName": "SEC-VLab",
"cveId": "CVE-2025-10548",
"datePublished": "2025-09-23T06:49:33.659Z",
"dateReserved": "2025-09-16T11:38:55.400Z",
"dateUpdated": "2025-11-03T18:08:42.269Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}