Search
Find a vulnerability
Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
1 vulnerability by CompuGroup Medical
CVE-2025-48981 (GCVE-0-2025-48981)
Vulnerability from cvelistv5 – Published: 2025-10-08 00:49 – Updated: 2025-10-09 01:06
VLAI
Summary
An insecure implementation of the proprietary protocol DNET in Product CGM MEDICO allows attackers within the intranet to eavesdrop and manipulate data on the protocol because encryption is optional for this connection.
Severity
8.6 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-311 - Missing Encryption of Sensitive Data
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| CompuGroup Medical | CGM MEDICO |
Affected:
29.0 , < 29.1
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-48981",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-08T13:18:24.008524Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-311",
"description": "CWE-311 Missing Encryption of Sensitive Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-08T13:20:43.202Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CGM MEDICO",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThan": "29.1",
"status": "affected",
"version": "29.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An insecure implementation of the proprietary protocol DNET in Product CGM MEDICO allows attackers within the intranet to eavesdrop and manipulate data on the protocol because encryption is optional for this connection."
}
],
"providerMetadata": {
"dateUpdated": "2025-10-09T01:06:32.695Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://www.cgm.com/deu_de/allgemein/cybersecurity-en/security-advisoriy.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2025-48981",
"datePublished": "2025-10-08T00:49:16.646Z",
"dateReserved": "2025-05-29T15:00:04.773Z",
"dateUpdated": "2025-10-09T01:06:32.695Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}