Search
Find a vulnerability
Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
2 vulnerabilities by Grup Arge Energy and Control Systems
CVE-2024-0851 (GCVE-0-2024-0851)
Vulnerability from nvd – Published: 2024-05-27 14:23 – Updated: 2026-06-03 14:39
VLAI
Title
SQLi in Grup Arge Energy and Control Systems's Smartpower
Summary
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in Grup Arge Energy and Control Systems Smartpower allows SQL Injection.
This issue affects Smartpower: through V24.05.27.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.usom.gov.tr/bildirim/tr-24-0556 | government-resourcebroken-link |
| https://siberguvenlik.gov.tr/guvenlik-bildirimler… | government-resource |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Grup Arge Energy and Control Systems | Smartpower |
Affected:
0 , ≤ V24.05.27
(custom)
|
|
| gruparge | smartpower |
Affected:
0 , ≤ 24.05.27
(custom)
cpe:2.3:a:gruparge:smartpower:-:*:*:*:*:*:*:* |
Date Public
2024-05-27 14:15
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:gruparge:smartpower:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "smartpower",
"vendor": "gruparge",
"versions": [
{
"lessThanOrEqual": "24.05.27",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0851",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-31T16:47:36.786306Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:58:30.549Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:18:18.909Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.usom.gov.tr/bildirim/tr-24-0556"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smartpower",
"vendor": "Grup Arge Energy and Control Systems",
"versions": [
{
"lessThanOrEqual": "V24.05.27",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Yusuf Kamil \u00c7AVU\u015eO\u011eLU"
}
],
"datePublic": "2024-05-27T14:15:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability in Grup Arge Energy and Control Systems Smartpower allows SQL Injection.\u003cp\u003eThis issue affects Smartpower: through V24.05.27.\u003c/p\u003e"
}
],
"value": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability in Grup Arge Energy and Control Systems Smartpower allows SQL Injection.\n\nThis issue affects Smartpower: through V24.05.27."
}
],
"impacts": [
{
"capecId": "CAPEC-66",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-66 SQL Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-03T14:39:53.209Z",
"orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"shortName": "TR-CERT"
},
"references": [
{
"tags": [
"government-resource",
"broken-link"
],
"url": "https://www.usom.gov.tr/bildirim/tr-24-0556"
},
{
"tags": [
"government-resource"
],
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-24-0556"
}
],
"source": {
"advisory": "TR-24-0556",
"defect": [
"TR-24-0556"
],
"discovery": "UNKNOWN"
},
"title": "SQLi in Grup Arge Energy and Control Systems\u0027s Smartpower",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"assignerShortName": "TR-CERT",
"cveId": "CVE-2024-0851",
"datePublished": "2024-05-27T14:23:57.642Z",
"dateReserved": "2024-01-24T07:32:38.422Z",
"dateUpdated": "2026-06-03T14:39:53.209Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-0851 (GCVE-0-2024-0851)
Vulnerability from cvelistv5 – Published: 2024-05-27 14:23 – Updated: 2026-06-03 14:39
VLAI
Title
SQLi in Grup Arge Energy and Control Systems's Smartpower
Summary
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in Grup Arge Energy and Control Systems Smartpower allows SQL Injection.
This issue affects Smartpower: through V24.05.27.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.usom.gov.tr/bildirim/tr-24-0556 | government-resourcebroken-link |
| https://siberguvenlik.gov.tr/guvenlik-bildirimler… | government-resource |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Grup Arge Energy and Control Systems | Smartpower |
Affected:
0 , ≤ V24.05.27
(custom)
|
|
| gruparge | smartpower |
Affected:
0 , ≤ 24.05.27
(custom)
cpe:2.3:a:gruparge:smartpower:-:*:*:*:*:*:*:* |
Date Public
2024-05-27 14:15
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:gruparge:smartpower:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "smartpower",
"vendor": "gruparge",
"versions": [
{
"lessThanOrEqual": "24.05.27",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0851",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-31T16:47:36.786306Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:58:30.549Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:18:18.909Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.usom.gov.tr/bildirim/tr-24-0556"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smartpower",
"vendor": "Grup Arge Energy and Control Systems",
"versions": [
{
"lessThanOrEqual": "V24.05.27",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Yusuf Kamil \u00c7AVU\u015eO\u011eLU"
}
],
"datePublic": "2024-05-27T14:15:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability in Grup Arge Energy and Control Systems Smartpower allows SQL Injection.\u003cp\u003eThis issue affects Smartpower: through V24.05.27.\u003c/p\u003e"
}
],
"value": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability in Grup Arge Energy and Control Systems Smartpower allows SQL Injection.\n\nThis issue affects Smartpower: through V24.05.27."
}
],
"impacts": [
{
"capecId": "CAPEC-66",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-66 SQL Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-03T14:39:53.209Z",
"orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"shortName": "TR-CERT"
},
"references": [
{
"tags": [
"government-resource",
"broken-link"
],
"url": "https://www.usom.gov.tr/bildirim/tr-24-0556"
},
{
"tags": [
"government-resource"
],
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-24-0556"
}
],
"source": {
"advisory": "TR-24-0556",
"defect": [
"TR-24-0556"
],
"discovery": "UNKNOWN"
},
"title": "SQLi in Grup Arge Energy and Control Systems\u0027s Smartpower",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"assignerShortName": "TR-CERT",
"cveId": "CVE-2024-0851",
"datePublished": "2024-05-27T14:23:57.642Z",
"dateReserved": "2024-01-24T07:32:38.422Z",
"dateUpdated": "2026-06-03T14:39:53.209Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}