Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    2 vulnerabilities by Grup Arge Energy and Control Systems

    CVE-2024-0851 (GCVE-0-2024-0851)

    Vulnerability from nvd – Published: 2024-05-27 14:23 – Updated: 2026-06-03 14:39
    VLAI
    Title
    SQLi in Grup Arge Energy and Control Systems's Smartpower
    Summary
    Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in Grup Arge Energy and Control Systems Smartpower allows SQL Injection. This issue affects Smartpower: through V24.05.27.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Grup Arge Energy and Control Systems Smartpower Affected: 0 , ≤ V24.05.27 (custom)
    Create a notification for this product.
    gruparge smartpower Affected: 0 , ≤ 24.05.27 (custom)
        cpe:2.3:a:gruparge:smartpower:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-05-27 14:15
    Credits
    Yusuf Kamil ÇAVUŞOĞLU
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:gruparge:smartpower:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "smartpower",
                "vendor": "gruparge",
                "versions": [
                  {
                    "lessThanOrEqual": "24.05.27",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-0851",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-31T16:47:36.786306Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T17:58:30.549Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:18:18.909Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.usom.gov.tr/bildirim/tr-24-0556"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smartpower",
              "vendor": "Grup Arge Energy and Control Systems",
              "versions": [
                {
                  "lessThanOrEqual": "V24.05.27",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Yusuf Kamil \u00c7AVU\u015eO\u011eLU"
            }
          ],
          "datePublic": "2024-05-27T14:15:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability in Grup Arge Energy and Control Systems Smartpower allows SQL Injection.\u003cp\u003eThis issue affects Smartpower: through V24.05.27.\u003c/p\u003e"
                }
              ],
              "value": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability in Grup Arge Energy and Control Systems Smartpower allows SQL Injection.\n\nThis issue affects Smartpower: through V24.05.27."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-66",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-66 SQL Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-03T14:39:53.209Z",
            "orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
            "shortName": "TR-CERT"
          },
          "references": [
            {
              "tags": [
                "government-resource",
                "broken-link"
              ],
              "url": "https://www.usom.gov.tr/bildirim/tr-24-0556"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-24-0556"
            }
          ],
          "source": {
            "advisory": "TR-24-0556",
            "defect": [
              "TR-24-0556"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "SQLi in  Grup Arge Energy and Control Systems\u0027s Smartpower",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
        "assignerShortName": "TR-CERT",
        "cveId": "CVE-2024-0851",
        "datePublished": "2024-05-27T14:23:57.642Z",
        "dateReserved": "2024-01-24T07:32:38.422Z",
        "dateUpdated": "2026-06-03T14:39:53.209Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-0851 (GCVE-0-2024-0851)

    Vulnerability from cvelistv5 – Published: 2024-05-27 14:23 – Updated: 2026-06-03 14:39
    VLAI
    Title
    SQLi in Grup Arge Energy and Control Systems's Smartpower
    Summary
    Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in Grup Arge Energy and Control Systems Smartpower allows SQL Injection. This issue affects Smartpower: through V24.05.27.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Grup Arge Energy and Control Systems Smartpower Affected: 0 , ≤ V24.05.27 (custom)
    Create a notification for this product.
    gruparge smartpower Affected: 0 , ≤ 24.05.27 (custom)
        cpe:2.3:a:gruparge:smartpower:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-05-27 14:15
    Credits
    Yusuf Kamil ÇAVUŞOĞLU
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:gruparge:smartpower:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "smartpower",
                "vendor": "gruparge",
                "versions": [
                  {
                    "lessThanOrEqual": "24.05.27",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-0851",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-31T16:47:36.786306Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T17:58:30.549Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:18:18.909Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.usom.gov.tr/bildirim/tr-24-0556"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smartpower",
              "vendor": "Grup Arge Energy and Control Systems",
              "versions": [
                {
                  "lessThanOrEqual": "V24.05.27",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Yusuf Kamil \u00c7AVU\u015eO\u011eLU"
            }
          ],
          "datePublic": "2024-05-27T14:15:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability in Grup Arge Energy and Control Systems Smartpower allows SQL Injection.\u003cp\u003eThis issue affects Smartpower: through V24.05.27.\u003c/p\u003e"
                }
              ],
              "value": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability in Grup Arge Energy and Control Systems Smartpower allows SQL Injection.\n\nThis issue affects Smartpower: through V24.05.27."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-66",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-66 SQL Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-03T14:39:53.209Z",
            "orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
            "shortName": "TR-CERT"
          },
          "references": [
            {
              "tags": [
                "government-resource",
                "broken-link"
              ],
              "url": "https://www.usom.gov.tr/bildirim/tr-24-0556"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-24-0556"
            }
          ],
          "source": {
            "advisory": "TR-24-0556",
            "defect": [
              "TR-24-0556"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "SQLi in  Grup Arge Energy and Control Systems\u0027s Smartpower",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
        "assignerShortName": "TR-CERT",
        "cveId": "CVE-2024-0851",
        "datePublished": "2024-05-27T14:23:57.642Z",
        "dateReserved": "2024-01-24T07:32:38.422Z",
        "dateUpdated": "2026-06-03T14:39:53.209Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }