CVE-2025-15114 (GCVE-0-2025-15114)
Vulnerability from cvelistv5 – Published: 2025-12-30 22:41 – Updated: 2025-12-30 22:41
VLAI?
Title
Ksenia Security Lares 4.0 Home Automation 1.6 PIN Exposure Vulnerability
Summary
Ksenia Security Lares 4.0 Home Automation version 1.6 contains a critical security flaw that exposes the alarm system PIN in the 'basisInfo' XML file after authentication. Attackers can retrieve the PIN from the server response to bypass security measures and disable the alarm system without additional authentication.
Severity ?
9.8 (Critical)
CWE
- CWE-403 - Exposure of File Descriptor to Unintended Control Sphere ('File Descriptor Leak')
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Ksenia Security S.p.A. | Ksenia Security Lares 4.0 Home Automation |
Affected:
1.6
Affected: 1.0.0.15 |
Credits
Mencha Isajlovska
{
"containers": {
"cna": {
"affected": [
{
"product": "Ksenia Security Lares 4.0 Home Automation",
"vendor": "Ksenia Security S.p.A.",
"versions": [
{
"status": "affected",
"version": "1.6"
},
{
"status": "affected",
"version": "1.0.0.15"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Mencha Isajlovska"
}
],
"datePublic": "2025-03-31T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Ksenia Security Lares 4.0 Home Automation version 1.6 contains a critical security flaw that exposes the alarm system PIN in the \u0027basisInfo\u0027 XML file after authentication. Attackers can retrieve the PIN from the server response to bypass security measures and disable the alarm system without additional authentication."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS"
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-403",
"description": "Exposure of File Descriptor to Unintended Control Sphere (\u0027File Descriptor Leak\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-30T22:41:47.116Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Zero Science Lab Disclosure (ZSL-2025-5929)",
"tags": [
"third-party-advisory"
],
"url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2025-5929.php"
},
{
"name": "VulnCheck Advisory: Ksenia Security Lares 4.0 Home Automation 1.6 PIN Exposure Vulnerability",
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/ksenia-security-lares-home-automation-pin-exposure-vulnerability"
}
],
"title": "Ksenia Security Lares 4.0 Home Automation 1.6 PIN Exposure Vulnerability",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2025-15114",
"datePublished": "2025-12-30T22:41:47.116Z",
"dateReserved": "2025-12-27T01:46:45.375Z",
"dateUpdated": "2025-12-30T22:41:47.116Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-15112 (GCVE-0-2025-15112)
Vulnerability from cvelistv5 – Published: 2025-12-30 22:41 – Updated: 2025-12-30 22:41
VLAI?
Title
Ksenia Security Lares 4.0 Home Automation 1.6 URL Redirection Vulnerability
Summary
Ksenia Security Lares 4.0 version 1.6 contains a URL redirection vulnerability in the 'cmdOk.xml' script that allows attackers to manipulate the 'redirectPage' GET parameter. Attackers can craft malicious links that redirect authenticated users to arbitrary websites when clicking on a specially constructed link hosted on a trusted domain.
Severity ?
CWE
- CWE-601 - URL Redirection to Untrusted Site ('Open Redirect')
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Ksenia Security S.p.A. | Ksenia Security Lares 4.0 Home Automation |
Affected:
1.6
Affected: 1.0.0.15 |
Credits
Mencha Isajlovska of Zero Science Lab
{
"containers": {
"cna": {
"affected": [
{
"product": "Ksenia Security Lares 4.0 Home Automation",
"vendor": "Ksenia Security S.p.A.",
"versions": [
{
"status": "affected",
"version": "1.6"
},
{
"status": "affected",
"version": "1.0.0.15"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Mencha Isajlovska of Zero Science Lab"
}
],
"datePublic": "2025-03-31T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Ksenia Security Lares 4.0 version 1.6 contains a URL redirection vulnerability in the \u0027cmdOk.xml\u0027 script that allows attackers to manipulate the \u0027redirectPage\u0027 GET parameter. Attackers can craft malicious links that redirect authenticated users to arbitrary websites when clicking on a specially constructed link hosted on a trusted domain."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS"
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-601",
"description": "URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-30T22:41:46.247Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Zero Science Lab Disclosure (ZSL-2025-5928)",
"tags": [
"third-party-advisory"
],
"url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2025-5928.php"
},
{
"name": "Packet Storm Security Exploit Entry",
"tags": [
"exploit"
],
"url": "https://packetstorm.news/files/id/190179/"
},
{
"name": "Ksenia Security Vendor Homepage",
"tags": [
"product"
],
"url": "https://www.kseniasecurity.com/"
},
{
"name": "VulnCheck Advisory: Ksenia Security Lares 4.0 Home Automation 1.6 URL Redirection Vulnerability",
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/ksenia-security-lares-home-automation-url-redirection-vulnerability"
}
],
"title": "Ksenia Security Lares 4.0 Home Automation 1.6 URL Redirection Vulnerability",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2025-15112",
"datePublished": "2025-12-30T22:41:46.247Z",
"dateReserved": "2025-12-27T01:46:41.722Z",
"dateUpdated": "2025-12-30T22:41:46.247Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-15113 (GCVE-0-2025-15113)
Vulnerability from cvelistv5 – Published: 2025-12-30 22:41 – Updated: 2025-12-30 22:41
VLAI?
Title
Ksenia Security Lares 4.0 Home Automation 1.6 Remote Code Execution via MPFS Upload
Summary
Ksenia Security Lares 4.0 Home Automation version 1.6 contains an unprotected endpoint vulnerability that allows authenticated attackers to upload MPFS File System binary images. Attackers can exploit this vulnerability to overwrite flash program memory and potentially execute arbitrary code on the home automation system's web server.
Severity ?
CWE
- CWE-256 - Plaintext Storage of a Password
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Ksenia Security S.p.A. | Ksenia Security Lares 4.0 Home Automation |
Affected:
1.6
Affected: 1.0.0.15 |
Credits
Mencha Isajlovska of Zero Science Lab
{
"containers": {
"cna": {
"affected": [
{
"product": "Ksenia Security Lares 4.0 Home Automation",
"vendor": "Ksenia Security S.p.A.",
"versions": [
{
"status": "affected",
"version": "1.6"
},
{
"status": "affected",
"version": "1.0.0.15"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Mencha Isajlovska of Zero Science Lab"
}
],
"datePublic": "2025-03-31T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Ksenia Security Lares 4.0 Home Automation version 1.6 contains an unprotected endpoint vulnerability that allows authenticated attackers to upload MPFS File System binary images. Attackers can exploit this vulnerability to overwrite flash program memory and potentially execute arbitrary code on the home automation system\u0027s web server."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS"
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-30T22:41:46.694Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Zero Science Lab Disclosure (ZSL-2025-5930)",
"tags": [
"third-party-advisory"
],
"url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2025-5930.php"
},
{
"name": "Ksenia Security Vendor Homepage",
"tags": [
"product"
],
"url": "https://www.kseniasecurity.com/"
},
{
"name": "Packet Storm Security Exploit",
"tags": [
"exploit"
],
"url": "https://packetstorm.news/files/id/190178/"
},
{
"name": "VulnCheck Advisory: Ksenia Security Lares 4.0 Home Automation 1.6 Remote Code Execution via MPFS Upload",
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/ksenia-security-lares-home-automation-remote-code-execution-via-mpfs-upload"
}
],
"title": "Ksenia Security Lares 4.0 Home Automation 1.6 Remote Code Execution via MPFS Upload",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2025-15113",
"datePublished": "2025-12-30T22:41:46.694Z",
"dateReserved": "2025-12-27T01:46:43.993Z",
"dateUpdated": "2025-12-30T22:41:46.694Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-15111 (GCVE-0-2025-15111)
Vulnerability from cvelistv5 – Published: 2025-12-30 22:41 – Updated: 2025-12-30 22:41
VLAI?
Title
Ksenia Security Lares 4.0 Home Automation 1.6 Default Credentials Vulnerability
Summary
Ksenia Security Lares 4.0 Home Automation version 1.6 contains a default credentials vulnerability that allows unauthorized attackers to gain administrative access. Attackers can exploit the weak default administrative credentials to obtain full control of the home automation system.
Severity ?
7.5 (High)
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Ksenia Security S.p.A. | Ksenia Security Lares 4.0 Home Automation |
Affected:
1.6
Affected: 1.0.0.15 |
Credits
Mencha Isajlovska of Zero Science Lab
{
"containers": {
"cna": {
"affected": [
{
"product": "Ksenia Security Lares 4.0 Home Automation",
"vendor": "Ksenia Security S.p.A.",
"versions": [
{
"status": "affected",
"version": "1.6"
},
{
"status": "affected",
"version": "1.0.0.15"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Mencha Isajlovska of Zero Science Lab"
}
],
"datePublic": "2025-03-31T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Ksenia Security Lares 4.0 Home Automation version 1.6 contains a default credentials vulnerability that allows unauthorized attackers to gain administrative access. Attackers can exploit the weak default administrative credentials to obtain full control of the home automation system."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS"
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-30T22:41:45.831Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Zero Science Lab Disclosure (ZSL-2025-5927)",
"tags": [
"third-party-advisory"
],
"url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2025-5927.php"
},
{
"name": "Packet Storm Security Exploit Entry",
"tags": [
"exploit"
],
"url": "https://packetstorm.news/files/id/190180/"
},
{
"name": "Ksenia Security Vendor Homepage",
"tags": [
"product"
],
"url": "https://www.kseniasecurity.com/"
},
{
"name": "VulnCheck Advisory: Ksenia Security Lares 4.0 Home Automation 1.6 Default Credentials Vulnerability",
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/ksenia-security-lares-home-automation-default-credentials-vulnerability"
}
],
"title": "Ksenia Security Lares 4.0 Home Automation 1.6 Default Credentials Vulnerability",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2025-15111",
"datePublished": "2025-12-30T22:41:45.831Z",
"dateReserved": "2025-12-27T01:44:38.682Z",
"dateUpdated": "2025-12-30T22:41:45.831Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}