CVE-2018-7675 (GCVE-0-2018-7675)
Vulnerability from cvelistv5 – Published: 2018-03-07 22:00 – Updated: 2024-08-05 06:31
VLAI?
Title
Potential Information Disclosure in Sentinel
Summary
In NetIQ Sentinel before 8.1.x, a Sentinel user is logged into the Sentinel Web Interface. After performing some tasks within Sentinel the user does not log out but does go idle for a period of time. This in turn causes the interface to timeout so that it requires the user to re-authenticate. If another user is passing by and decides to login, their credentials are accepted. While The user does not inherit any of the other users privileges, they are able to view the previous screen. In this case it is possible that the user can see another users events or configuration information for whatever view is currently showing.
Severity ?
CWE
- Potential information leakage
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| NetIQ Corporation | Sentinel |
Affected:
Sentinel 8.1.X 8.1.X
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:31:05.057Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7022706"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Sentinel",
"vendor": "NetIQ Corporation",
"versions": [
{
"status": "affected",
"version": "Sentinel 8.1.X 8.1.X"
}
]
}
],
"datePublic": "2018-03-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "In NetIQ Sentinel before 8.1.x, a Sentinel user is logged into the Sentinel Web Interface. After performing some tasks within Sentinel the user does not log out but does go idle for a period of time. This in turn causes the interface to timeout so that it requires the user to re-authenticate. If another user is passing by and decides to login, their credentials are accepted. While The user does not inherit any of the other users privileges, they are able to view the previous screen. In this case it is possible that the user can see another users events or configuration information for whatever view is currently showing."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 2.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Potential information leakage",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:52",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/support/kb/doc.php?id=7022706"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Potential Information Disclosure in Sentinel",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2018-7675",
"STATE": "PUBLIC",
"TITLE": "Potential Information Disclosure in Sentinel"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Sentinel",
"version": {
"version_data": [
{
"affected": "=",
"version_affected": "=",
"version_name": "Sentinel 8.1.X",
"version_value": "8.1.X"
}
]
}
}
]
},
"vendor_name": "NetIQ Corporation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In NetIQ Sentinel before 8.1.x, a Sentinel user is logged into the Sentinel Web Interface. After performing some tasks within Sentinel the user does not log out but does go idle for a period of time. This in turn causes the interface to timeout so that it requires the user to re-authenticate. If another user is passing by and decides to login, their credentials are accepted. While The user does not inherit any of the other users privileges, they are able to view the previous screen. In this case it is possible that the user can see another users events or configuration information for whatever view is currently showing."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 2.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Potential information leakage"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.netiq.com/support/kb/doc.php?id=7022706",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/support/kb/doc.php?id=7022706"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2018-7675",
"datePublished": "2018-03-07T22:00:00",
"dateReserved": "2018-03-05T00:00:00",
"dateUpdated": "2024-08-05T06:31:05.057Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-7425 (GCVE-0-2017-7425)
Vulnerability from cvelistv5 – Published: 2017-11-06 17:00 – Updated: 2024-08-05 16:04
VLAI?
Title
Multiple Reflected XSS in iManager
Summary
Multiple potential reflected XSS issues exist in NetIQ iManager versions before 2.7.7 Patch 10 HF2 and 3.0.3.2.
Severity ?
7.6 (High)
CWE
- XSS
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| NetIQ Corporation | NetIQ iManager |
Affected:
2.7.7 Patch 10 HF2
Affected: 3.0.3.2 |
Credits
Special thanks is given to Pawel.Batunek@ingservicespolska.pl for finding and reporting this issue as part of the responsible disclosure process..
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:04:11.210Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/documentation/imanager-3/imanager3032_releasenotes/data/imanager3032_releasenotes.html"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7021423"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.netiq.com/documentation/imanager/imanager27710hf2readme/data/imanager27710hf2readme.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NetIQ iManager",
"vendor": "NetIQ Corporation",
"versions": [
{
"status": "affected",
"version": "2.7.7 Patch 10 HF2"
},
{
"status": "affected",
"version": "3.0.3.2"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Special thanks is given to Pawel.Batunek@ingservicespolska.pl for finding and reporting this issue as part of the responsible disclosure process.."
}
],
"datePublic": "2017-11-06T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Multiple potential reflected XSS issues exist in NetIQ iManager versions before 2.7.7 Patch 10 HF2 and 3.0.3.2."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "XSS",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:49",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7016795"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/documentation/imanager-3/imanager3032_releasenotes/data/imanager3032_releasenotes.html"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.novell.com/support/kb/doc.php?id=7021423"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.netiq.com/documentation/imanager/imanager27710hf2readme/data/imanager27710hf2readme.html"
}
],
"title": "Multiple Reflected XSS in iManager",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2017-7425",
"STATE": "PUBLIC",
"TITLE": "Multiple Reflected XSS in iManager"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NetIQ iManager",
"version": {
"version_data": [
{
"version_value": "2.7.7 Patch 10 HF2"
},
{
"version_value": "3.0.3.2"
}
]
}
}
]
},
"vendor_name": "NetIQ Corporation"
}
]
}
},
"credit": [
"Special thanks is given to Pawel.Batunek@ingservicespolska.pl for finding and reporting this issue as part of the responsible disclosure process.."
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple potential reflected XSS issues exist in NetIQ iManager versions before 2.7.7 Patch 10 HF2 and 3.0.3.2."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "XSS"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.novell.com/support/kb/doc.php?id=7016795",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=7016795"
},
{
"name": "https://www.netiq.com/documentation/imanager-3/imanager3032_releasenotes/data/imanager3032_releasenotes.html",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/documentation/imanager-3/imanager3032_releasenotes/data/imanager3032_releasenotes.html"
},
{
"name": "https://www.novell.com/support/kb/doc.php?id=7021423",
"refsource": "CONFIRM",
"url": "https://www.novell.com/support/kb/doc.php?id=7021423"
},
{
"name": "https://www.netiq.com/documentation/imanager/imanager27710hf2readme/data/imanager27710hf2readme.html",
"refsource": "CONFIRM",
"url": "https://www.netiq.com/documentation/imanager/imanager27710hf2readme/data/imanager27710hf2readme.html"
}
]
},
"solution": "See 2.7.7.10 release notes located here: https://www.netiq.com/documentation/imanager/imanager27710hf2readme/data/imanager27710hf2readme.html \nSee 3.0.3.2 release notes located here: https://www.netiq.com/documentation/imanager-3/imanager3032_releasenotes/data/imanager3032_releasenotes.html"
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2017-7425",
"datePublished": "2017-11-06T17:00:00",
"dateReserved": "2017-04-05T00:00:00",
"dateUpdated": "2024-08-05T16:04:11.210Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}