Search criteria

1 vulnerability by SunPower

CVE-2025-9696 (GCVE-0-2025-9696)

Vulnerability from cvelistv5 – Published: 2025-09-02 16:34 – Updated: 2025-09-02 17:39
VLAI?
Title
Use of Hard-coded Credentials in SunPower PVS6
Summary
The SunPower PVS6's BluetoothLE interface is vulnerable due to its use of hardcoded encryption parameters and publicly accessible protocol details. An attacker within Bluetooth range could exploit this vulnerability to gain full access to the device's servicing interface. This access allows the attacker to perform actions such as firmware replacement, disabling power production, modifying grid settings, creating SSH tunnels, altering firewall settings, and manipulating connected devices.
CWE
  • CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
Vendor Product Version
SunPower PVS6 Affected: 0 , ≤ 2025.06 build 61839 (custom)
Create a notification for this product.
Credits
Dagan Henderson
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9696",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-02T17:39:53.214845Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-02T17:39:59.231Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PVS6",
          "vendor": "SunPower",
          "versions": [
            {
              "lessThanOrEqual": "2025.06 build 61839",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dagan Henderson"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThe SunPower PVS6\u0027s BluetoothLE interface is vulnerable due to its use of hardcoded encryption parameters and publicly accessible protocol details. An attacker within Bluetooth range could exploit this vulnerability to gain full access to the device\u0027s servicing interface. This access allows the attacker to perform actions such as firmware replacement, disabling power production, modifying grid settings, creating SSH tunnels, altering firewall settings, and manipulating connected devices.\u003c/p\u003e"
            }
          ],
          "value": "The SunPower PVS6\u0027s BluetoothLE interface is vulnerable due to its use of hardcoded encryption parameters and publicly accessible protocol details. An attacker within Bluetooth range could exploit this vulnerability to gain full access to the device\u0027s servicing interface. This access allows the attacker to perform actions such as firmware replacement, disabling power production, modifying grid settings, creating SSH tunnels, altering firewall settings, and manipulating connected devices."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-02T16:34:35.362Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-245-03"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Use of Hard-coded Credentials in SunPower PVS6",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eSunPower did not respond to CISA\u0027s attempt to coordinate these vulnerabilities. Users should contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://us.sunpower.com/contact-us\"\u003eSunPower\u003c/a\u003e\u0026nbsp;for more information.\u003c/p\u003e\u003cbr\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "SunPower did not respond to CISA\u0027s attempt to coordinate these vulnerabilities. Users should contact  SunPower https://us.sunpower.com/contact-us \u00a0for more information."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-9696",
    "datePublished": "2025-09-02T16:34:35.362Z",
    "dateReserved": "2025-08-29T14:17:40.379Z",
    "dateUpdated": "2025-09-02T17:39:59.231Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}