CVE-2022-43663 (GCVE-0-2022-43663)

Vulnerability from cvelistv5 – Published: 2023-03-20 20:16 – Updated: 2024-08-03 13:40
VLAI?
Summary
An integer conversion vulnerability exists in the SORBAx64.dll RecvPacket functionality of WellinTech KingHistorian 35.01.00.05. A specially crafted network packet can lead to a buffer overflow. An attacker can send a malicious packet to trigger this vulnerability.
CWE
  • CWE-195 - Signed to Unsigned Conversion Error
Assigner
Impacted products
Vendor Product Version
WellinTech KingHistorian Affected: 35.01.00.05
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:40:06.410Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1674"
          },
          {
            "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1674",
            "tags": [
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1674"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:wellintech:kinghistorian:35.01.00.05:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "kinghistorian",
            "vendor": "wellintech",
            "versions": [
              {
                "status": "affected",
                "version": "35.01.00.05"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43663",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-01T15:29:22.467498Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-01T15:29:50.814Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "KingHistorian",
          "vendor": "WellinTech",
          "versions": [
            {
              "status": "affected",
              "version": "35.01.00.05"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An integer conversion vulnerability exists in the SORBAx64.dll RecvPacket functionality of WellinTech KingHistorian 35.01.00.05. A specially crafted network packet can lead to a buffer overflow. An attacker can send a malicious packet to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-195",
              "description": "CWE-195: Signed to Unsigned Conversion Error",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-20T20:16:02.048Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1674",
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1674"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2022-43663",
    "datePublished": "2023-03-20T20:16:02.048Z",
    "dateReserved": "2022-11-28T20:48:15.949Z",
    "dateUpdated": "2024-08-03T13:40:06.410Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-45124 (GCVE-0-2022-45124)

Vulnerability from cvelistv5 – Published: 2023-03-20 20:16 – Updated: 2024-08-03 14:01
VLAI?
Summary
An information disclosure vulnerability exists in the User authentication functionality of WellinTech KingHistorian 35.01.00.05. A specially crafted network packet can lead to a disclosure of sensitive information. An attacker can sniff network traffic to leverage this vulnerability.
CWE
Assigner
Impacted products
Vendor Product Version
WellinTech KingHistorian Affected: 35.01.00.05
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T14:01:31.496Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1683"
          },
          {
            "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1683",
            "tags": [
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1683"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:wellintech:kinghistorian:35.01.00.05:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "kinghistorian",
            "vendor": "wellintech",
            "versions": [
              {
                "status": "affected",
                "version": "35.01.00.05"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-45124",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-01T15:54:23.660785Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-01T15:55:30.541Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "KingHistorian",
          "vendor": "WellinTech",
          "versions": [
            {
              "status": "affected",
              "version": "35.01.00.05"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An information disclosure vulnerability exists in the User authentication functionality of WellinTech KingHistorian 35.01.00.05. A specially crafted network packet can lead to a disclosure of sensitive information. An attacker can sniff network traffic to leverage this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200: Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-20T20:16:01.634Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1683",
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1683"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2022-45124",
    "datePublished": "2023-03-20T20:16:01.634Z",
    "dateReserved": "2022-12-02T21:42:11.766Z",
    "dateUpdated": "2024-08-03T14:01:31.496Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-20410 (GCVE-0-2018-20410)

Vulnerability from cvelistv5 – Published: 2018-12-24 02:00 – Updated: 2024-09-16 16:18
VLAI?
Summary
WellinTech KingSCADA before 3.7.0.0.1 contains a stack-based buffer overflow. The vulnerability is triggered when sending a specially crafted packet to the AlarmServer (AEserver.exe) service listening on TCP port 12401.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:58:19.268Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/flypuma/vul/blob/master/kingview/copy_argumengt_overflow/poc.py"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/flypuma/vul/blob/master/kingview/copy_argumengt_overflow/Debugging.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "WellinTech KingSCADA before 3.7.0.0.1 contains a stack-based buffer overflow. The vulnerability is triggered when sending a specially crafted packet to the AlarmServer (AEserver.exe) service listening on TCP port 12401."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-12-24T02:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/flypuma/vul/blob/master/kingview/copy_argumengt_overflow/poc.py"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/flypuma/vul/blob/master/kingview/copy_argumengt_overflow/Debugging.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-20410",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "WellinTech KingSCADA before 3.7.0.0.1 contains a stack-based buffer overflow. The vulnerability is triggered when sending a specially crafted packet to the AlarmServer (AEserver.exe) service listening on TCP port 12401."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/flypuma/vul/blob/master/kingview/copy_argumengt_overflow/poc.py",
              "refsource": "MISC",
              "url": "https://github.com/flypuma/vul/blob/master/kingview/copy_argumengt_overflow/poc.py"
            },
            {
              "name": "https://github.com/flypuma/vul/blob/master/kingview/copy_argumengt_overflow/Debugging.md",
              "refsource": "MISC",
              "url": "https://github.com/flypuma/vul/blob/master/kingview/copy_argumengt_overflow/Debugging.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-20410",
    "datePublished": "2018-12-24T02:00:00Z",
    "dateReserved": "2018-12-23T00:00:00Z",
    "dateUpdated": "2024-09-16T16:18:42.221Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-0787 (GCVE-0-2014-0787)

Vulnerability from cvelistv5 – Published: 2014-04-12 01:00 – Updated: 2025-09-25 17:39
VLAI?
Summary
Stack-based buffer overflow in WellinTech KingSCADA before 3.1.2.13 allows remote attackers to execute arbitrary code via a crafted packet.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
WellinTech KingSCADA Affected: 0 , < v3.1.2.13 (custom)
Create a notification for this product.
Credits
HP’s Zero Day Initiative
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T09:27:19.475Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-098-02"
          },
          {
            "name": "42724",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "https://www.exploit-db.com/exploits/42724/"
          },
          {
            "name": "66709",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/66709"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "KingSCADA",
          "vendor": "WellinTech",
          "versions": [
            {
              "lessThan": "v3.1.2.13",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "HP\u2019s Zero Day Initiative"
        }
      ],
      "datePublic": "2014-04-08T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eStack-based buffer overflow in WellinTech KingSCADA before 3.1.2.13 allows remote attackers to execute arbitrary code via a crafted packet.\u003c/p\u003e"
            }
          ],
          "value": "Stack-based buffer overflow in WellinTech KingSCADA before 3.1.2.13 allows remote attackers to execute arbitrary code via a crafted packet."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-25T17:39:03.344Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-098-02"
        },
        {
          "name": "42724",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "https://www.exploit-db.com/exploits/42724/"
        },
        {
          "name": "66709",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/66709"
        },
        {
          "url": "http://www.wellintech.com/index.php?option=com_content\u0026view=article\u0026id=56\u0026Itemid=11"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eWellinTech has created a patch and instructions for installation that are available for download on its web site at:\u003c/p\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.wellintech.com/index.php?option=com_content\u0026amp;view=article\u0026amp;id=56\u0026amp;Itemid=11\"\u003ehttp://www.wellintech.com/index.php?option=com_content\u0026amp;view=article\u0026amp;id=56\u0026amp;Itemid=11\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "WellinTech has created a patch and instructions for installation that are available for download on its web site at:\n\n http://www.wellintech.com/index.php?option=com_content\u0026view=article\u0026id=56\u0026Itemid=11"
        }
      ],
      "source": {
        "advisory": "ICSA-14-098-02",
        "discovery": "EXTERNAL"
      },
      "title": "WellinTech KingSCADA Stack-based Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-0787",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Stack-based buffer overflow in WellinTech KingSCADA before 3.1.2.13 allows remote attackers to execute arbitrary code via a crafted packet."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-098-02",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-098-02"
            },
            {
              "name": "42724",
              "refsource": "EXPLOIT-DB",
              "url": "https://www.exploit-db.com/exploits/42724/"
            },
            {
              "name": "66709",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/66709"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-0787",
    "datePublished": "2014-04-12T01:00:00",
    "dateReserved": "2014-01-02T00:00:00",
    "dateUpdated": "2025-09-25T17:39:03.344Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-2826 (GCVE-0-2013-2826)

Vulnerability from cvelistv5 – Published: 2014-01-15 16:00 – Updated: 2024-08-06 15:52
VLAI?
Summary
WellinTech KingSCADA before 3.1.2, KingAlarm&Event before 3.1, and KingGraphic before 3.1.2 perform authentication on the KAEClientManager console rather than on the server, which allows remote attackers to bypass intended access restrictions and discover credentials via a crafted packet to TCP port 8130.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T15:52:20.967Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-344-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2014-01-14T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "WellinTech KingSCADA before 3.1.2, KingAlarm\u0026Event before 3.1, and KingGraphic before 3.1.2 perform authentication on the KAEClientManager console rather than on the server, which allows remote attackers to bypass intended access restrictions and discover credentials via a crafted packet to TCP port 8130."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2014-01-15T16:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-344-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-2826",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "WellinTech KingSCADA before 3.1.2, KingAlarm\u0026Event before 3.1, and KingGraphic before 3.1.2 perform authentication on the KAEClientManager console rather than on the server, which allows remote attackers to bypass intended access restrictions and discover credentials via a crafted packet to TCP port 8130."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-344-01",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-344-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2013-2826",
    "datePublished": "2014-01-15T16:00:00",
    "dateReserved": "2013-04-11T00:00:00",
    "dateUpdated": "2024-08-06T15:52:20.967Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-2827 (GCVE-0-2013-2827)

Vulnerability from cvelistv5 – Published: 2014-01-15 16:00 – Updated: 2024-08-06 15:52
VLAI?
Summary
An unspecified ActiveX control in WellinTech KingSCADA before 3.1.2, KingAlarm&Event before 3.1, and KingGraphic before 3.1.2 allows remote attackers to download arbitrary DLL code onto a client machine and execute this code via the ProjectURL property value.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T15:52:20.033Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-344-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2014-01-14T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An unspecified ActiveX control in WellinTech KingSCADA before 3.1.2, KingAlarm\u0026Event before 3.1, and KingGraphic before 3.1.2 allows remote attackers to download arbitrary DLL code onto a client machine and execute this code via the ProjectURL property value."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2014-01-15T16:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-344-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-2827",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An unspecified ActiveX control in WellinTech KingSCADA before 3.1.2, KingAlarm\u0026Event before 3.1, and KingGraphic before 3.1.2 allows remote attackers to download arbitrary DLL code onto a client machine and execute this code via the ProjectURL property value."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-344-01",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-344-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2013-2827",
    "datePublished": "2014-01-15T16:00:00",
    "dateReserved": "2013-04-11T00:00:00",
    "dateUpdated": "2024-08-06T15:52:20.033Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-6128 (GCVE-0-2013-6128)

Vulnerability from cvelistv5 – Published: 2013-10-25 20:00 – Updated: 2024-09-16 20:47
VLAI?
Summary
The KCHARTXYLib.KChartXY ActiveX control in KChartXY.ocx before 65.30.30000.10002 in WellinTech KingView before 6.53 does not properly restrict SaveToFile method calls, which allows remote attackers to create or overwrite arbitrary files, and subsequently execute arbitrary programs, via the single pathname argument, as demonstrated by a directory traversal attack.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T17:29:42.974Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "28085",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "http://www.exploit-db.com/exploits/28085/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-295-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The KCHARTXYLib.KChartXY ActiveX control in KChartXY.ocx before 65.30.30000.10002 in WellinTech KingView before 6.53 does not properly restrict SaveToFile method calls, which allows remote attackers to create or overwrite arbitrary files, and subsequently execute arbitrary programs, via the single pathname argument, as demonstrated by a directory traversal attack."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-10-25T20:00:00Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "28085",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "http://www.exploit-db.com/exploits/28085/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-295-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-6128",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The KCHARTXYLib.KChartXY ActiveX control in KChartXY.ocx before 65.30.30000.10002 in WellinTech KingView before 6.53 does not properly restrict SaveToFile method calls, which allows remote attackers to create or overwrite arbitrary files, and subsequently execute arbitrary programs, via the single pathname argument, as demonstrated by a directory traversal attack."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "28085",
              "refsource": "EXPLOIT-DB",
              "url": "http://www.exploit-db.com/exploits/28085/"
            },
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-295-01",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-295-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2013-6128",
    "datePublished": "2013-10-25T20:00:00Z",
    "dateReserved": "2013-10-15T00:00:00Z",
    "dateUpdated": "2024-09-16T20:47:34.907Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-6127 (GCVE-0-2013-6127)

Vulnerability from cvelistv5 – Published: 2013-10-25 20:00 – Updated: 2024-09-17 00:37
VLAI?
Summary
The SUPERGRIDLib.SuperGrid ActiveX control in SuperGrid.ocx before 65.30.30000.10002 in WellinTech KingView before 6.53 does not properly restrict ReplaceDBFile method calls, which allows remote attackers to create or overwrite arbitrary files, and subsequently execute arbitrary programs, via the two pathname arguments, as demonstrated by a directory traversal attack.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T17:29:43.044Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "28084",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "http://www.exploit-db.com/exploits/28084/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-295-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The SUPERGRIDLib.SuperGrid ActiveX control in SuperGrid.ocx before 65.30.30000.10002 in WellinTech KingView before 6.53 does not properly restrict ReplaceDBFile method calls, which allows remote attackers to create or overwrite arbitrary files, and subsequently execute arbitrary programs, via the two pathname arguments, as demonstrated by a directory traversal attack."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-10-25T20:00:00Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "28084",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "http://www.exploit-db.com/exploits/28084/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-295-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-6127",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The SUPERGRIDLib.SuperGrid ActiveX control in SuperGrid.ocx before 65.30.30000.10002 in WellinTech KingView before 6.53 does not properly restrict ReplaceDBFile method calls, which allows remote attackers to create or overwrite arbitrary files, and subsequently execute arbitrary programs, via the two pathname arguments, as demonstrated by a directory traversal attack."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "28084",
              "refsource": "EXPLOIT-DB",
              "url": "http://www.exploit-db.com/exploits/28084/"
            },
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-295-01",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-295-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2013-6127",
    "datePublished": "2013-10-25T20:00:00Z",
    "dateReserved": "2013-10-15T00:00:00Z",
    "dateUpdated": "2024-09-17T00:37:21.751Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2012-4711 (GCVE-0-2012-4711)

Vulnerability from cvelistv5 – Published: 2013-02-15 11:00 – Updated: 2024-08-06 20:42
VLAI?
Summary
Buffer overflow in kingMess.exe 65.20.2003.10300 in WellinTech KingView 6.52, kingMess.exe 65.20.2003.10400 in KingView 6.53, and kingMess.exe 65.50.2011.18049 in KingView 6.55 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted packet.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T20:42:55.095Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-043-02.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-043-02A"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2013-02-12T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Buffer overflow in kingMess.exe 65.20.2003.10300 in WellinTech KingView 6.52, kingMess.exe 65.20.2003.10400 in KingView 6.53, and kingMess.exe 65.50.2011.18049 in KingView 6.55 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted packet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-05-21T09:00:00",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-043-02.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-043-02A"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2012-4711",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Buffer overflow in kingMess.exe 65.20.2003.10300 in WellinTech KingView 6.52, kingMess.exe 65.20.2003.10400 in KingView 6.53, and kingMess.exe 65.50.2011.18049 in KingView 6.55 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted packet."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://ics-cert.us-cert.gov/pdf/ICSA-13-043-02.pdf",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-043-02.pdf"
            },
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-043-02A",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-043-02A"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2012-4711",
    "datePublished": "2013-02-15T11:00:00",
    "dateReserved": "2012-08-28T00:00:00",
    "dateUpdated": "2024-08-06T20:42:55.095Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2012-4899 (GCVE-0-2012-4899)

Vulnerability from cvelistv5 – Published: 2012-10-10 18:00 – Updated: 2024-09-16 22:19
VLAI?
Summary
WellinTech KingView 6.5.3 and earlier uses a weak password-hashing algorithm, which makes it easier for local users to discover credentials by reading an unspecified file.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T20:50:17.973Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-02.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "WellinTech KingView 6.5.3 and earlier uses a weak password-hashing algorithm, which makes it easier for local users to discover credentials by reading an unspecified file."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-10-10T18:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-02.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2012-4899",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "WellinTech KingView 6.5.3 and earlier uses a weak password-hashing algorithm, which makes it easier for local users to discover credentials by reading an unspecified file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653",
              "refsource": "MISC",
              "url": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653"
            },
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-02.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-02.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2012-4899",
    "datePublished": "2012-10-10T18:00:00Z",
    "dateReserved": "2012-09-12T00:00:00Z",
    "dateUpdated": "2024-09-16T22:19:42.129Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2012-1831 (GCVE-0-2012-1831)

Vulnerability from cvelistv5 – Published: 2012-07-05 01:00 – Updated: 2024-09-16 18:43
VLAI?
Summary
Heap-based buffer overflow in WellinTech KingView 6.53 allows remote attackers to execute arbitrary code via a crafted packet to TCP port 555.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T19:08:38.696Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Heap-based buffer overflow in WellinTech KingView 6.53 allows remote attackers to execute arbitrary code via a crafted packet to TCP port 555."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-07-05T01:00:00Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2012-1831",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Heap-based buffer overflow in WellinTech KingView 6.53 allows remote attackers to execute arbitrary code via a crafted packet to TCP port 555."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf"
            },
            {
              "name": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653",
              "refsource": "CONFIRM",
              "url": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2012-1831",
    "datePublished": "2012-07-05T01:00:00Z",
    "dateReserved": "2012-03-21T00:00:00Z",
    "dateUpdated": "2024-09-16T18:43:21.581Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2012-1832 (GCVE-0-2012-1832)

Vulnerability from cvelistv5 – Published: 2012-07-05 01:00 – Updated: 2024-09-17 04:19
VLAI?
Summary
WellinTech KingView 6.53 allows remote attackers to execute arbitrary code or cause a denial of service (out-of-bounds read) via a crafted packet to (1) TCP or (2) UDP port 2001.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T19:08:38.489Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "WellinTech KingView 6.53 allows remote attackers to execute arbitrary code or cause a denial of service (out-of-bounds read) via a crafted packet to (1) TCP or (2) UDP port 2001."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-07-05T01:00:00Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2012-1832",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "WellinTech KingView 6.53 allows remote attackers to execute arbitrary code or cause a denial of service (out-of-bounds read) via a crafted packet to (1) TCP or (2) UDP port 2001."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf"
            },
            {
              "name": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653",
              "refsource": "CONFIRM",
              "url": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2012-1832",
    "datePublished": "2012-07-05T01:00:00Z",
    "dateReserved": "2012-03-21T00:00:00Z",
    "dateUpdated": "2024-09-17T04:19:22.332Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2012-2559 (GCVE-0-2012-2559)

Vulnerability from cvelistv5 – Published: 2012-07-05 01:00 – Updated: 2024-09-16 22:15
VLAI?
Summary
WellinTech KingHistorian 3.0 allows remote attackers to execute arbitrary code or cause a denial of service (invalid pointer write) via a crafted packet to TCP port 5678.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T19:34:25.911Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "WellinTech KingHistorian 3.0 allows remote attackers to execute arbitrary code or cause a denial of service (invalid pointer write) via a crafted packet to TCP port 5678."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-07-05T01:00:00Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2012-2559",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "WellinTech KingHistorian 3.0 allows remote attackers to execute arbitrary code or cause a denial of service (invalid pointer write) via a crafted packet to TCP port 5678."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2012-2559",
    "datePublished": "2012-07-05T01:00:00Z",
    "dateReserved": "2012-05-09T00:00:00Z",
    "dateUpdated": "2024-09-16T22:15:15.445Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2012-2560 (GCVE-0-2012-2560)

Vulnerability from cvelistv5 – Published: 2012-07-05 01:00 – Updated: 2024-09-16 19:25
VLAI?
Summary
Directory traversal vulnerability in WellinTech KingView 6.53 allows remote attackers to read arbitrary files via a crafted HTTP request to port 8001.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T19:34:25.906Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Directory traversal vulnerability in WellinTech KingView 6.53 allows remote attackers to read arbitrary files via a crafted HTTP request to port 8001."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-07-05T01:00:00Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2012-2560",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Directory traversal vulnerability in WellinTech KingView 6.53 allows remote attackers to read arbitrary files via a crafted HTTP request to port 8001."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf"
            },
            {
              "name": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653",
              "refsource": "CONFIRM",
              "url": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2012-2560",
    "datePublished": "2012-07-05T01:00:00Z",
    "dateReserved": "2012-05-09T00:00:00Z",
    "dateUpdated": "2024-09-16T19:25:49.875Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2012-1830 (GCVE-0-2012-1830)

Vulnerability from cvelistv5 – Published: 2012-07-05 01:00 – Updated: 2024-09-17 02:46
VLAI?
Summary
Stack-based buffer overflow in WellinTech KingView 6.53 allows remote attackers to execute arbitrary code via a crafted packet to TCP port 555.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T19:08:38.616Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based buffer overflow in WellinTech KingView 6.53 allows remote attackers to execute arbitrary code via a crafted packet to TCP port 555."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-07-05T01:00:00Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2012-1830",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Stack-based buffer overflow in WellinTech KingView 6.53 allows remote attackers to execute arbitrary code via a crafted packet to TCP port 555."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-185-01.pdf"
            },
            {
              "name": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653",
              "refsource": "CONFIRM",
              "url": "http://www.wellintech.com/index.php/news/33-patch-for-kingview653"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2012-1830",
    "datePublished": "2012-07-05T01:00:00Z",
    "dateReserved": "2012-03-21T00:00:00Z",
    "dateUpdated": "2024-09-17T02:46:36.270Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2012-1977 (GCVE-0-2012-1977)

Vulnerability from cvelistv5 – Published: 2012-05-09 10:00 – Updated: 2025-06-26 21:30
VLAI?
Summary
WellinTech KingSCADA 3.0 uses a cleartext base64 format for storage of passwords in user.db, which allows context-dependent attackers to obtain sensitive information by reading this file.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Credits
Independent researchers Alexandr Polyakov and Alexey Sintsov from DSecRG identified an unsecure password encryption vulnerability in WellinTech KingSCADA application.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T19:17:27.498Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://dsecrg.com/pages/vul/show.php?id=405"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-129-01.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "KingSCADA",
          "vendor": "WellinTech",
          "versions": [
            {
              "status": "affected",
              "version": "3.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Independent researchers Alexandr Polyakov and Alexey Sintsov from DSecRG identified an unsecure password encryption vulnerability in WellinTech KingSCADA application."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eWellinTech KingSCADA 3.0 uses a cleartext base64 format for storage of passwords in user.db, which allows context-dependent attackers to obtain sensitive information by reading this file.\u003c/p\u003e"
            }
          ],
          "value": "WellinTech KingSCADA 3.0 uses a cleartext base64 format for storage of passwords in user.db, which allows context-dependent attackers to obtain sensitive information by reading this file."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "NONE",
            "baseScore": 7.1,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "NONE",
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:N/A:N",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-311",
              "description": "CWE-311",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-26T21:30:25.305Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-12-129-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eWellinTech has provided the following link to the latest version of KingSCADA: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://download.kingview.com/software/KingSCADA/EN/KingSCADA3.1_2012-04-16EN.rar\"\u003ehttp://download.kingview.com/software/KingSCADA/EN/KingSCADA3.1_2012-04-16EN.rar\u003c/a\u003e.\u003c/p\u003e\u003cp\u003eAccording to WellinTech, this new version securely hashes passwords.\u003c/p\u003e"
            }
          ],
          "value": "WellinTech has provided the following link to the latest version of KingSCADA:  http://download.kingview.com/software/KingSCADA/EN/KingSCADA3.1_2012-04-16EN.rar .\n\nAccording to WellinTech, this new version securely hashes passwords."
        }
      ],
      "source": {
        "advisory": "ICSA-12-129-01",
        "discovery": "EXTERNAL"
      },
      "title": "WellinTech KingSCADA Missing Encryption of Sensitive Data",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2012-1977",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "WellinTech KingSCADA 3.0 uses a cleartext base64 format for storage of passwords in user.db, which allows context-dependent attackers to obtain sensitive information by reading this file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://dsecrg.com/pages/vul/show.php?id=405",
              "refsource": "MISC",
              "url": "http://dsecrg.com/pages/vul/show.php?id=405"
            },
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-129-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-129-01.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2012-1977",
    "datePublished": "2012-05-09T10:00:00Z",
    "dateReserved": "2012-03-30T00:00:00Z",
    "dateUpdated": "2025-06-26T21:30:25.305Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2012-1819 (GCVE-0-2012-1819)

Vulnerability from cvelistv5 – Published: 2012-05-02 22:00 – Updated: 2024-08-06 19:08
VLAI?
Summary
Untrusted search path vulnerability in WellinTech KingView 6.53 allows local users to gain privileges via a Trojan horse DLL in the current working directory.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T19:08:38.515Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://en.wellintech.com/news/detail.aspx?contentid=168"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-122-01.pdf"
          },
          {
            "name": "53316",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/53316"
          },
          {
            "name": "kingview-dll-code-execution(75309)",
            "tags": [
              "vdb-entry",
              "x_refsource_XF",
              "x_transferred"
            ],
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/75309"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2012-03-22T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Untrusted search path vulnerability in WellinTech KingView 6.53 allows local users to gain privileges via a Trojan horse DLL in the current working directory."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-13T18:57:01",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://en.wellintech.com/news/detail.aspx?contentid=168"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-122-01.pdf"
        },
        {
          "name": "53316",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/53316"
        },
        {
          "name": "kingview-dll-code-execution(75309)",
          "tags": [
            "vdb-entry",
            "x_refsource_XF"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/75309"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2012-1819",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Untrusted search path vulnerability in WellinTech KingView 6.53 allows local users to gain privileges via a Trojan horse DLL in the current working directory."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://en.wellintech.com/news/detail.aspx?contentid=168",
              "refsource": "CONFIRM",
              "url": "http://en.wellintech.com/news/detail.aspx?contentid=168"
            },
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-122-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-122-01.pdf"
            },
            {
              "name": "53316",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/53316"
            },
            {
              "name": "kingview-dll-code-execution(75309)",
              "refsource": "XF",
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/75309"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2012-1819",
    "datePublished": "2012-05-02T22:00:00",
    "dateReserved": "2012-03-21T00:00:00",
    "dateUpdated": "2024-08-06T19:08:38.515Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2011-4536 (GCVE-0-2011-4536)

Vulnerability from cvelistv5 – Published: 2011-12-27 02:00 – Updated: 2024-09-16 23:20
VLAI?
Summary
Heap-based buffer overflow in nettransdll.dll in HistorySvr.exe (aka HistoryServer.exe) in WellinTech KingView 6.53 and 65.30.2010.18018 allows remote attackers to execute arbitrary code via a crafted op-code 3 packet.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-07T00:09:18.931Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.zerodayinitiative.com/advisories/ZDI-11-351/"
          },
          {
            "name": "77992",
            "tags": [
              "vdb-entry",
              "x_refsource_OSVDB",
              "x_transferred"
            ],
            "url": "http://www.osvdb.org/77992"
          },
          {
            "name": "47339",
            "tags": [
              "third-party-advisory",
              "x_refsource_SECUNIA",
              "x_transferred"
            ],
            "url": "http://secunia.com/advisories/47339"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://en.wellintech.com/news/detail.aspx?contentid=166"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kingview.com/news/detail.aspx?contentid=587"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-355-02.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Heap-based buffer overflow in nettransdll.dll in HistorySvr.exe (aka HistoryServer.exe) in WellinTech KingView 6.53 and 65.30.2010.18018 allows remote attackers to execute arbitrary code via a crafted op-code 3 packet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2011-12-27T02:00:00Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.zerodayinitiative.com/advisories/ZDI-11-351/"
        },
        {
          "name": "77992",
          "tags": [
            "vdb-entry",
            "x_refsource_OSVDB"
          ],
          "url": "http://www.osvdb.org/77992"
        },
        {
          "name": "47339",
          "tags": [
            "third-party-advisory",
            "x_refsource_SECUNIA"
          ],
          "url": "http://secunia.com/advisories/47339"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://en.wellintech.com/news/detail.aspx?contentid=166"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kingview.com/news/detail.aspx?contentid=587"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-355-02.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2011-4536",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Heap-based buffer overflow in nettransdll.dll in HistorySvr.exe (aka HistoryServer.exe) in WellinTech KingView 6.53 and 65.30.2010.18018 allows remote attackers to execute arbitrary code via a crafted op-code 3 packet."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.zerodayinitiative.com/advisories/ZDI-11-351/",
              "refsource": "MISC",
              "url": "http://www.zerodayinitiative.com/advisories/ZDI-11-351/"
            },
            {
              "name": "77992",
              "refsource": "OSVDB",
              "url": "http://www.osvdb.org/77992"
            },
            {
              "name": "47339",
              "refsource": "SECUNIA",
              "url": "http://secunia.com/advisories/47339"
            },
            {
              "name": "http://en.wellintech.com/news/detail.aspx?contentid=166",
              "refsource": "CONFIRM",
              "url": "http://en.wellintech.com/news/detail.aspx?contentid=166"
            },
            {
              "name": "http://www.kingview.com/news/detail.aspx?contentid=587",
              "refsource": "CONFIRM",
              "url": "http://www.kingview.com/news/detail.aspx?contentid=587"
            },
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-355-02.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-355-02.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2011-4536",
    "datePublished": "2011-12-27T02:00:00Z",
    "dateReserved": "2011-11-22T00:00:00Z",
    "dateUpdated": "2024-09-16T23:20:33.549Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2011-3142 (GCVE-0-2011-3142)

Vulnerability from cvelistv5 – Published: 2011-08-16 21:00 – Updated: 2024-09-17 01:20
VLAI?
Summary
Stack-based buffer overflow in an ActiveX control in KVWebSvr.dll in WellinTech KingView 6.52 and 6.53 allows remote attackers to execute arbitrary code via a long second argument to the ValidateUser method.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T23:22:27.632Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.scadahacker.com/exploits-wellintech-kvwebsvr.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-074-01.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.cnvd.org.cn/vulnerability/CNVD-2011-04541"
          },
          {
            "name": "16936",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "http://www.exploit-db.com/exploits/16936"
          },
          {
            "name": "46757",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/46757"
          },
          {
            "name": "72889",
            "tags": [
              "vdb-entry",
              "x_refsource_OSVDB",
              "x_transferred"
            ],
            "url": "http://www.osvdb.org/72889"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-066-01.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kingview.com/news/detail.aspx?contentid=537"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based buffer overflow in an ActiveX control in KVWebSvr.dll in WellinTech KingView 6.52 and 6.53 allows remote attackers to execute arbitrary code via a long second argument to the ValidateUser method."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2011-08-16T21:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.scadahacker.com/exploits-wellintech-kvwebsvr.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-074-01.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.cnvd.org.cn/vulnerability/CNVD-2011-04541"
        },
        {
          "name": "16936",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "http://www.exploit-db.com/exploits/16936"
        },
        {
          "name": "46757",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/46757"
        },
        {
          "name": "72889",
          "tags": [
            "vdb-entry",
            "x_refsource_OSVDB"
          ],
          "url": "http://www.osvdb.org/72889"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-066-01.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kingview.com/news/detail.aspx?contentid=537"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2011-3142",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Stack-based buffer overflow in an ActiveX control in KVWebSvr.dll in WellinTech KingView 6.52 and 6.53 allows remote attackers to execute arbitrary code via a long second argument to the ValidateUser method."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.scadahacker.com/exploits-wellintech-kvwebsvr.html",
              "refsource": "MISC",
              "url": "http://www.scadahacker.com/exploits-wellintech-kvwebsvr.html"
            },
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-074-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-074-01.pdf"
            },
            {
              "name": "http://www.cnvd.org.cn/vulnerability/CNVD-2011-04541",
              "refsource": "MISC",
              "url": "http://www.cnvd.org.cn/vulnerability/CNVD-2011-04541"
            },
            {
              "name": "16936",
              "refsource": "EXPLOIT-DB",
              "url": "http://www.exploit-db.com/exploits/16936"
            },
            {
              "name": "46757",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/46757"
            },
            {
              "name": "72889",
              "refsource": "OSVDB",
              "url": "http://www.osvdb.org/72889"
            },
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-066-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-066-01.pdf"
            },
            {
              "name": "http://www.kingview.com/news/detail.aspx?contentid=537",
              "refsource": "CONFIRM",
              "url": "http://www.kingview.com/news/detail.aspx?contentid=537"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2011-3142",
    "datePublished": "2011-08-16T21:00:00Z",
    "dateReserved": "2011-08-16T00:00:00Z",
    "dateUpdated": "2024-09-17T01:20:36.573Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2011-0406 (GCVE-0-2011-0406)

Vulnerability from cvelistv5 – Published: 2011-01-11 01:00 – Updated: 2024-08-06 21:51
VLAI?
Summary
Heap-based buffer overflow in HistorySvr.exe in WellinTech KingView 6.53 allows remote attackers to execute arbitrary code via a long request to TCP port 777.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
https://exchange.xforce.ibmcloud.com/vulnerabilit… vdb-entryx_refsource_XF
http://www.exploit-db.com/exploits/15957 exploitx_refsource_EXPLOIT-DB
http://www.securityfocus.com/bid/45727 vdb-entryx_refsource_BID
http://www.cnnvd.org.cn/showCnnvd.html?id=2011010108 x_refsource_MISC
http://secunia.com/advisories/42851 third-party-advisoryx_refsource_SECUNIA
http://osvdb.org/70366 vdb-entryx_refsource_OSVDB
http://securityreason.com/securityalert/8134 third-party-advisoryx_refsource_SREASON
http://www.vupen.com/english/advisories/2011/0063 vdb-entryx_refsource_VUPEN
http://thesauceofutterpwnage.blogspot.com/2011/01… x_refsource_MISC
http://www.kingview.com/news/detail.aspx?contentid=528 x_refsource_CONFIRM
http://www.kb.cert.org/vuls/id/180119 third-party-advisoryx_refsource_CERT-VN
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T21:51:08.939Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "kingview-historysvr-bo(64559)",
            "tags": [
              "vdb-entry",
              "x_refsource_XF",
              "x_transferred"
            ],
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/64559"
          },
          {
            "name": "15957",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "http://www.exploit-db.com/exploits/15957"
          },
          {
            "name": "45727",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/45727"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.cnnvd.org.cn/showCnnvd.html?id=2011010108"
          },
          {
            "name": "42851",
            "tags": [
              "third-party-advisory",
              "x_refsource_SECUNIA",
              "x_transferred"
            ],
            "url": "http://secunia.com/advisories/42851"
          },
          {
            "name": "70366",
            "tags": [
              "vdb-entry",
              "x_refsource_OSVDB",
              "x_transferred"
            ],
            "url": "http://osvdb.org/70366"
          },
          {
            "name": "8134",
            "tags": [
              "third-party-advisory",
              "x_refsource_SREASON",
              "x_transferred"
            ],
            "url": "http://securityreason.com/securityalert/8134"
          },
          {
            "name": "ADV-2011-0063",
            "tags": [
              "vdb-entry",
              "x_refsource_VUPEN",
              "x_transferred"
            ],
            "url": "http://www.vupen.com/english/advisories/2011/0063"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://thesauceofutterpwnage.blogspot.com/2011/01/waking-up-sleeping-dragon.html"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kingview.com/news/detail.aspx?contentid=528"
          },
          {
            "name": "VU#180119",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/180119"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2011-01-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Heap-based buffer overflow in HistorySvr.exe in WellinTech KingView 6.53 allows remote attackers to execute arbitrary code via a long request to TCP port 777."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-08-16T14:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "kingview-historysvr-bo(64559)",
          "tags": [
            "vdb-entry",
            "x_refsource_XF"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/64559"
        },
        {
          "name": "15957",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "http://www.exploit-db.com/exploits/15957"
        },
        {
          "name": "45727",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/45727"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.cnnvd.org.cn/showCnnvd.html?id=2011010108"
        },
        {
          "name": "42851",
          "tags": [
            "third-party-advisory",
            "x_refsource_SECUNIA"
          ],
          "url": "http://secunia.com/advisories/42851"
        },
        {
          "name": "70366",
          "tags": [
            "vdb-entry",
            "x_refsource_OSVDB"
          ],
          "url": "http://osvdb.org/70366"
        },
        {
          "name": "8134",
          "tags": [
            "third-party-advisory",
            "x_refsource_SREASON"
          ],
          "url": "http://securityreason.com/securityalert/8134"
        },
        {
          "name": "ADV-2011-0063",
          "tags": [
            "vdb-entry",
            "x_refsource_VUPEN"
          ],
          "url": "http://www.vupen.com/english/advisories/2011/0063"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://thesauceofutterpwnage.blogspot.com/2011/01/waking-up-sleeping-dragon.html"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kingview.com/news/detail.aspx?contentid=528"
        },
        {
          "name": "VU#180119",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/180119"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2011-0406",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Heap-based buffer overflow in HistorySvr.exe in WellinTech KingView 6.53 allows remote attackers to execute arbitrary code via a long request to TCP port 777."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "kingview-historysvr-bo(64559)",
              "refsource": "XF",
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/64559"
            },
            {
              "name": "15957",
              "refsource": "EXPLOIT-DB",
              "url": "http://www.exploit-db.com/exploits/15957"
            },
            {
              "name": "45727",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/45727"
            },
            {
              "name": "http://www.cnnvd.org.cn/showCnnvd.html?id=2011010108",
              "refsource": "MISC",
              "url": "http://www.cnnvd.org.cn/showCnnvd.html?id=2011010108"
            },
            {
              "name": "42851",
              "refsource": "SECUNIA",
              "url": "http://secunia.com/advisories/42851"
            },
            {
              "name": "70366",
              "refsource": "OSVDB",
              "url": "http://osvdb.org/70366"
            },
            {
              "name": "8134",
              "refsource": "SREASON",
              "url": "http://securityreason.com/securityalert/8134"
            },
            {
              "name": "ADV-2011-0063",
              "refsource": "VUPEN",
              "url": "http://www.vupen.com/english/advisories/2011/0063"
            },
            {
              "name": "http://thesauceofutterpwnage.blogspot.com/2011/01/waking-up-sleeping-dragon.html",
              "refsource": "MISC",
              "url": "http://thesauceofutterpwnage.blogspot.com/2011/01/waking-up-sleeping-dragon.html"
            },
            {
              "name": "http://www.kingview.com/news/detail.aspx?contentid=528",
              "refsource": "CONFIRM",
              "url": "http://www.kingview.com/news/detail.aspx?contentid=528"
            },
            {
              "name": "VU#180119",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/180119"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2011-0406",
    "datePublished": "2011-01-11T01:00:00",
    "dateReserved": "2011-01-10T00:00:00",
    "dateUpdated": "2024-08-06T21:51:08.939Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}