Search criteria

4 vulnerabilities by accelerite

CVE-2015-7860 (GCVE-0-2015-7860)

Vulnerability from cvelistv5 – Published: 2015-10-19 18:00 – Updated: 2024-08-06 08:06
VLAI
Summary
Stack-based buffer overflow in the agent in Persistent Accelerite Radia Client Automation (formerly HP Client Automation), possibly before 9.1, allows remote attackers to execute arbitrary code by sending a large amount of data in an environment that lacks relationship-based firewalling.
Severity
No CVSS data available.
CWE
  • n/a
Assigner
References
URL Tags
http://www.kb.cert.org/vuls/id/966927 third-party-advisoryx_refsource_CERT-VN
http://www.securityfocus.com/bid/75966 vdb-entryx_refsource_BID
http://www.securitytracker.com/id/1033861 vdb-entryx_refsource_SECTRACK
http://zerodayinitiative.com/advisories/ZDI-15-363/ x_refsource_MISC
Date Public
2015-07-20 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T08:06:30.627Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VU#966927",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/966927"
          },
          {
            "name": "75966",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/75966"
          },
          {
            "name": "1033861",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1033861"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://zerodayinitiative.com/advisories/ZDI-15-363/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2015-07-20T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based buffer overflow in the agent in Persistent Accelerite Radia Client Automation (formerly HP Client Automation), possibly before 9.1, allows remote attackers to execute arbitrary code by sending a large amount of data in an environment that lacks relationship-based firewalling."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2016-12-22T18:57:01.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "VU#966927",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/966927"
        },
        {
          "name": "75966",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/75966"
        },
        {
          "name": "1033861",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1033861"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://zerodayinitiative.com/advisories/ZDI-15-363/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2015-7860",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Stack-based buffer overflow in the agent in Persistent Accelerite Radia Client Automation (formerly HP Client Automation), possibly before 9.1, allows remote attackers to execute arbitrary code by sending a large amount of data in an environment that lacks relationship-based firewalling."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "VU#966927",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/966927"
            },
            {
              "name": "75966",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/75966"
            },
            {
              "name": "1033861",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1033861"
            },
            {
              "name": "http://zerodayinitiative.com/advisories/ZDI-15-363/",
              "refsource": "MISC",
              "url": "http://zerodayinitiative.com/advisories/ZDI-15-363/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2015-7860",
    "datePublished": "2015-10-19T18:00:00.000Z",
    "dateReserved": "2015-10-19T00:00:00.000Z",
    "dateUpdated": "2024-08-06T08:06:30.627Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2015-7861 (GCVE-0-2015-7861)

Vulnerability from cvelistv5 – Published: 2015-10-19 18:00 – Updated: 2024-08-06 08:06
VLAI
Summary
Persistent Accelerite Radia Client Automation (formerly HP Client Automation), possibly before 9.1, allows remote attackers to execute arbitrary code by sending unspecified commands in an environment that lacks relationship-based firewalling.
Severity
No CVSS data available.
CWE
  • n/a
Assigner
References
URL Tags
http://www.kb.cert.org/vuls/id/966927 third-party-advisoryx_refsource_CERT-VN
http://zerodayinitiative.com/advisories/ZDI-15-364/ x_refsource_MISC
http://www.securityfocus.com/bid/75966 vdb-entryx_refsource_BID
http://www.securitytracker.com/id/1033861 vdb-entryx_refsource_SECTRACK
Date Public
2015-07-20 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T08:06:30.879Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VU#966927",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/966927"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://zerodayinitiative.com/advisories/ZDI-15-364/"
          },
          {
            "name": "75966",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/75966"
          },
          {
            "name": "1033861",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1033861"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2015-07-20T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Persistent Accelerite Radia Client Automation (formerly HP Client Automation), possibly before 9.1, allows remote attackers to execute arbitrary code by sending unspecified commands in an environment that lacks relationship-based firewalling."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2016-12-22T18:57:01.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "VU#966927",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/966927"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://zerodayinitiative.com/advisories/ZDI-15-364/"
        },
        {
          "name": "75966",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/75966"
        },
        {
          "name": "1033861",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1033861"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2015-7861",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Persistent Accelerite Radia Client Automation (formerly HP Client Automation), possibly before 9.1, allows remote attackers to execute arbitrary code by sending unspecified commands in an environment that lacks relationship-based firewalling."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "VU#966927",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/966927"
            },
            {
              "name": "http://zerodayinitiative.com/advisories/ZDI-15-364/",
              "refsource": "MISC",
              "url": "http://zerodayinitiative.com/advisories/ZDI-15-364/"
            },
            {
              "name": "75966",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/75966"
            },
            {
              "name": "1033861",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1033861"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2015-7861",
    "datePublished": "2015-10-19T18:00:00.000Z",
    "dateReserved": "2015-10-19T00:00:00.000Z",
    "dateUpdated": "2024-08-06T08:06:30.879Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2015-7862 (GCVE-0-2015-7862)

Vulnerability from cvelistv5 – Published: 2015-10-19 18:00 – Updated: 2024-08-06 08:06
VLAI
Summary
Persistent Accelerite Radia Client Automation (formerly HP Client Automation) 7.9 through 9.1 before 2015-02-19 improperly implements the Role Based Access Control feature, which might allow remote attackers to modify an account's role assignments via unspecified vectors.
Severity
No CVSS data available.
CWE
  • n/a
Assigner
References
URL Tags
http://www.securitytracker.com/id/1033862 vdb-entryx_refsource_SECTRACK
https://support.accelerite.com/hc/en-us/articles/… x_refsource_CONFIRM
Date Public
2015-02-19 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T08:06:29.884Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "1033862",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1033862"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.accelerite.com/hc/en-us/articles/203659814-Accelerite-releases-solutions-and-best-practices-to-enhance-the-security-for-RBAC-and-Remote-Notify-features"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2015-02-19T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Persistent Accelerite Radia Client Automation (formerly HP Client Automation) 7.9 through 9.1 before 2015-02-19 improperly implements the Role Based Access Control feature, which might allow remote attackers to modify an account\u0027s role assignments via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2016-12-22T18:57:01.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "1033862",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1033862"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.accelerite.com/hc/en-us/articles/203659814-Accelerite-releases-solutions-and-best-practices-to-enhance-the-security-for-RBAC-and-Remote-Notify-features"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2015-7862",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Persistent Accelerite Radia Client Automation (formerly HP Client Automation) 7.9 through 9.1 before 2015-02-19 improperly implements the Role Based Access Control feature, which might allow remote attackers to modify an account\u0027s role assignments via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "1033862",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1033862"
            },
            {
              "name": "https://support.accelerite.com/hc/en-us/articles/203659814-Accelerite-releases-solutions-and-best-practices-to-enhance-the-security-for-RBAC-and-Remote-Notify-features",
              "refsource": "CONFIRM",
              "url": "https://support.accelerite.com/hc/en-us/articles/203659814-Accelerite-releases-solutions-and-best-practices-to-enhance-the-security-for-RBAC-and-Remote-Notify-features"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2015-7862",
    "datePublished": "2015-10-19T18:00:00.000Z",
    "dateReserved": "2015-10-19T00:00:00.000Z",
    "dateUpdated": "2024-08-06T08:06:29.884Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2015-7863 (GCVE-0-2015-7863)

Vulnerability from cvelistv5 – Published: 2015-10-19 18:00 – Updated: 2024-08-06 08:06
VLAI
Summary
The default configuration of Persistent Accelerite Radia Client Automation (formerly HP Client Automation) 7.9 through 9.1 before 2015-02-19 enables a remote Notify capability without the Extended Notify Security features, which might allow remote attackers to bypass intended access restrictions via unspecified vectors.
Severity
No CVSS data available.
CWE
  • n/a
Assigner
References
URL Tags
http://www.securitytracker.com/id/1033862 vdb-entryx_refsource_SECTRACK
https://support.accelerite.com/hc/en-us/articles/… x_refsource_CONFIRM
Date Public
2015-02-19 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T08:06:30.287Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "1033862",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1033862"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.accelerite.com/hc/en-us/articles/203659814-Accelerite-releases-solutions-and-best-practices-to-enhance-the-security-for-RBAC-and-Remote-Notify-features"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2015-02-19T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The default configuration of Persistent Accelerite Radia Client Automation (formerly HP Client Automation) 7.9 through 9.1 before 2015-02-19 enables a remote Notify capability without the Extended Notify Security features, which might allow remote attackers to bypass intended access restrictions via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2016-12-22T18:57:01.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "1033862",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1033862"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.accelerite.com/hc/en-us/articles/203659814-Accelerite-releases-solutions-and-best-practices-to-enhance-the-security-for-RBAC-and-Remote-Notify-features"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2015-7863",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The default configuration of Persistent Accelerite Radia Client Automation (formerly HP Client Automation) 7.9 through 9.1 before 2015-02-19 enables a remote Notify capability without the Extended Notify Security features, which might allow remote attackers to bypass intended access restrictions via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "1033862",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1033862"
            },
            {
              "name": "https://support.accelerite.com/hc/en-us/articles/203659814-Accelerite-releases-solutions-and-best-practices-to-enhance-the-security-for-RBAC-and-Remote-Notify-features",
              "refsource": "CONFIRM",
              "url": "https://support.accelerite.com/hc/en-us/articles/203659814-Accelerite-releases-solutions-and-best-practices-to-enhance-the-security-for-RBAC-and-Remote-Notify-features"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2015-7863",
    "datePublished": "2015-10-19T18:00:00.000Z",
    "dateReserved": "2015-10-19T00:00:00.000Z",
    "dateUpdated": "2024-08-06T08:06:30.287Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}